2C Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 NMG Series Magnetic Line Starters and Enclosures 600VAC Heavy Duty Applications: NMG magnetic line starters are used: • For magnetic across-the-line starting of motors and remote starting and stopping • For across-the-line starting of polyphase AC induction motors • To provide motor running protection, undervoltage protection and remote starting and stopping 2C Features: • Enclosures are made of Eaton's CrouseHinds high-impact strength Krydon® fiberglass-reinforced polyester material which has excellent corrosion resistance and stability to heat. • Unitized, strong and durable enclosure construction provides longer service life for equipment. • Exterior parts of RESET button made of Krydon material. Certifications and Compliances: • NEMA/EEMAC: 3, 4X and 12 Electrical Rating Ranges: • Starter sizes 0, 1, 2, 3, 4 Magnetic line starter with optional hinged cover with START-STOP pushbuttons. Options: Description Hinged cover..................................... Pilot lights, 120 V primary – specify other primary voltages as required: Red pilot light............................... Green pilot light............................ LED pilot lights in place of standard incandescent pilot lamps................. Pushbutton (heavy duty, uses two device holes): START-STOP.............................. Selector switches (heavy duty): ON-OFF........................................ HAND-OFF-AUTO........................ JOG-RUN-OFF............................. Padlock attachment for: Pushbutton.................................. Control circuit transformer 480 / 240-120 volts, 50 or 60 hertz, (sizes 0 and 1–50VA, size 2–100VA, size 3–150VA, size 4–300VA): Fusible Secondary................................... Primary and Secondary............... Automatic reset overload relay.......... Less overload relays (contactor)........ Auxiliary Contact on Starter or Contactor: 1NO/1NC..................................... 2NO/2NC..................................... 3NO/3NC..................................... Suffix NH J1* J3* LED PB13* RR17* RR18* RR19* S708 Description Suffix Time delay low voltage release for 3-wire control with 2, 4 or 6-second adjustment. For single-speed, nonreversing starters only. Control circuit voltage: 120 volt, 60 hertz............................ LVR1 240 volt, 60 hertz............................ LVR2 480 volt, 60 hertz............................ LVR3 Hubs (see "Note on Hubs") – see page 677 Grounding plate or bushing† – see page 677 Insulated, groundable type terminal block for a grounded or ungrounded neutral can be supplied..................... S618 Information on other options or combination of options for a specific enclosure size is available on request. FT FTPS S1 C S781 S782 S783 †Type GP grounding plate only in NMG0710 enclosure. *For optional devices or control circuit transformer, use next larger enclosure size. For NMG0714, two device holes maximum. 488 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 NMG Series Magnetic Line Starters and Enclosures 600VAC Heavy Duty Ordering Information Dimensions† To order an enclosure complete with starter, insert the manufacturer’s symbol in the designated position of the catalog number. Symbols are shown in the footnote at the bottom of this page. Specify HP, voltage, frequency, RPM, type and full load ampere rating of motor – or specify ampere rating of heaters. In Inches: 2C Starters are furnished with three heaters. Enclosures only can be ordered. Select from listings. Single-Speed, Non-Reversing Motor Starter Enclosure Max. HP Volts NEMA With Polyphase (AC) Size Starter Cat. # 120 120 240 480 600 120 240 480 600 120 240 480 600 240 240 480 600 480 600 0 1 0 0 0 2 1 1 1 3 2 2 2 3 4 3 3 4 4 NMG0710 NMG0710 NMG0710 NMG0710 NMG0710 NMG0714 NMG0710 NMG0710 NMG0710 NMG1018 NMG0714 NMG0714 NMG0714 NMG1018 NMG1024 NMG1018 NMG1018 NMG1024 NMG1024 ➀6130 ➀6131 ➀6230 ➀6430 ➀6530 ➀6132 ➀6231 ➀6431 ➀6531 ➀6133 ➀6232 ➀6432 ➀6532 ➀6233 ➀6234* ➀6433 ➀6533 ➀6434* ➀6534* NMG0710 NMG0710 NMG0710 NMG0710 NMG0710 NMG0714 NMG0710 NMG0710 NMG0710 NMG1018 NMG0714 NMG0714 NMG0714 NMG1018 NMG1024 NMG1018 NMG1018 NMG1024 NMG1024 NMG0710 & 0714 2C 2 3 3 5 5 71/2 71/2 10 10 15 15 25 25 30 50 50 50 100 100 Without Starter Cat. # NMG1018 & 1024 *NEMA Size 4 Allen-Bradley starter must be in NMG1426 enclosure. ➀ Motor Starters: Manufacturer Allen-Bradley Square D Cutler-Hammer General Electric Westinghouse Enclosure Cat. # Outside Dimensions l w d Mounting Dimensions ml mw NMG0710 NMG0714 NMG1018 NMG1024 101/2 141/2 1913/32 2513/32 93/8 133/8 193/8 253/8 Symbol AB D C G W Information on other starter manufacturers on request. Ordering Information when adding options 71/2 71/2 1113/32 1113/32 7 7 823/32 823/32 63/8 63/8 77/8 77/8 †Not to be used for construction purposes unless approved. When adding options to NMG series enclosures, the base catalog number must be changed according to the table below. NEMA Enclosure Enclosure Size Cat. # w/Options 0, 1 NMG0710 NMG0714 2 NMG0714 NMG1018 3 NMG1018 NMG1024 4 NMG1024 NMG1426 Example: A NEMA size 4, 480 V Westinghouse starter with STARTSTOP pushbuttons would be Cat. No. NMG1426-W6434-PB13. Note on Hubs: The following number and sizes of hubs (not mounted) are included when magnetic starters are ordered complete. If enclosures only are ordered, hubs must be ordered separately (see "Options"). Starter Size Number Included Hub Size 0 3 3 1 1 2 /4 1 2 1 2 3 /4 11/2 3 1 2 3 /4 2 4 1 2 3 /4 21/2 /4 3 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 489