2C Motor Starters Hazardous and Non

advertisement
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0341-2 Name: 2C-341
100:
DATE: JAN 19 2006
Time: 5:18:12 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Motor Starters
Hazardous and Non-Hazardous
2C
Description
Page No.
Application/Selection
342
Magnetic Line Starters & Enclosures
Single speed, non-reversing
EBMS Series
EPC Series
EBMS Series with Advantage* Starter
343-346
349-351
347, 348
Manual Line Starters & Enclosures
EMN Series
353
Manual Motor Starting Switches & Enclosures
EFD Series
MC Series
EDS Series
GHG 635 Series
354
360, 361
355-357
358, 359
Special Feature Kits
For EPC Series
352
*Advantage is a trademark of Cutler-Hammer Inc.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:341))
CH0 0 0 0 2 C
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
341
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0342-2 Name: 2C-342
DATE: JAN 19 2006
Time: 5:18:13 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Motor Starters
2C
Application and Selection
Quick Selector Chart
Application:
Selection:
Options:
Line starters are housed in enclosures
suitable for specific environments, and are
used for:
ɀ across-the-line starting of motors
ɀ motor running protection
ɀ undervoltage protection
ɀ remote or manual starting and stopping
Considerations for selection of proper
enclosure:
ɀ The environment of the enclosure location
in accordance with NEC/CEC and NEMA/
EEMAC requirements
ɀ The characteristics of the starter to be
enclosed
ɀ See ‘‘Quick-Selector’’ below for guidance
Many options are available on:
ɀ material and finishes where special
atmospheric conditions prevail
ɀ special features for specific applications.
See individual listings for available options,
many of which are available in kit form for
field addition to existing units.
Quick Selector Chart
Enclosures for Starters
NEMA/EEMAC
Size
Starters
Single Speed
Non-reversing
Enclosures
NEC/CEC – Hazardous
Area Compliance
NEMA/
EEMAC
Enclosure
Type
MC
None
3,4,12
Manual
EPC
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
3,4,7CD,
9EFG,12
Magnetic
0-2
Poly-AC
Allen-Bradley
Cutler-Hammer
G.E.
Square D
Threaded
EBMS
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
3,4,7BCD,
9EFG,12
Magnetic
0-5
Poly-AC
Allen-Bradley
G.E.
Square D
Cutler-Hammer
Bolted/
Ground Joint/
Gasketed
EMN
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
3, 7CD,
9EFG,12
Manual
0-1P
Single and
Poly-AC
Allen-Bradley
Cutler-Hammer
G.E.
Square D
Bolted/
Ground Joint
EDS,
Cl. I, Div. 1 & 2, Groups B*,C,D
EDSC‡ Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
3,7CD,
9EFG,12
Manual
DC and
Single AC
Allen-Bradley
G.E.
Cutler-Hammer
Bolted/
Ground Joint
EFD
3,7BCD,
9EFG,12
Manual
DC and
Single and
Poly-AC
G.E.
Square D
Bolted/
Ground Joint
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
Starter
Type
Motor Phase
and Type
Manufacturers
Equipment
Enclosed
– Starter
Cover Type
Single-AC
Cutler-Hammer
Gasketed
‡ Factory sealed units listed on pages 440 and 441.
* Check listings for Group B suitability.
342
STIBOINFO((CRH:66008com:2C:342))
CH0 0 2 C- 0
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0343-1 Name: 2C-343
100:
DATE: JAN 19 2006
Time: 5:18:14 PM Operator: RB
EBMS Magnetic Line Starters
and Enclosures
Application:
Spectrum EBM TM hinged cover motor control
enclosures are used:
ɀ For general motor control – indoors or
outdoors – in damp, wet, dirty, dusty
hazardous locations, without the need for a
protective shelter.
ɀ In areas where frequent washdowns are
necessary or where heavy rain or water spray
is prevalent.
ɀ For across-the-line starting, stopping,
speed changing and reversing of polyphase
AC induction motors.
ɀ To provide motor overload and
undervoltage protection.
ɀ On switchracks or other assemblies where
it’s desired that motor control be centrally
located.
Features:
ɀ Rugged, corrosion resistant, cast copperfree aluminum construction (less than 0.4 of
1%).
ɀ Motor starter operating handle located
through the right side wall of the body
permits visual confirmation of correct
component assembly and operation.
ɀ Total compliance to the wiring end room
requirements of the National Electrical Code®
and Canadian Electrical Code.
ɀ Semi-clamshell enclosure design, with an
external flanged ground joint between body
and cover makes interior components more
accessible.
ɀ Minimum enclosure-to-enclosure spacing
with little interference between the opened
cover and an adjacent enclosure.
ɀ Copper-free aluminum hinges allow the
cover to swing well out of the way.
ɀ Stainless steel, quick release, captive, hex
head cover bolts. Stainless steel springs
provide clear indication cover bolts are fully
retracted from body.
ɀ Versatile, internal operating mechanisms
allow for field adjustment to accommodate
popular manufacturers’ starters.
ɀ Simple, straightforward installation of
starter on pre-drilled mounting plate within
enclosure. Mounting plate also field
removable.
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4‡,7BCD,9EFG,12
ɀ Neoprene cover gasket permanently
attached to the cover seals out moisture.
ɀ Bodies have top and bottom drilled and
tapped entrances for power conduits plus
one at the bottom for control conduit.
Removable reducers are supplied as
standard, to accommodate smaller size
conduits. All conduit entrances are plugged.
ɀ Tap-on mounting feet.
ɀ Optional EMPS control devices may be
added to enclosure cover.
ɀ Steel bracket for lifting larger enclosures
during installation supplied as standard.
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
2C
Standard Materials:
ɀ Body and cover – copper-free aluminum
ɀ Operating handle – copper-free aluminum
ɀ Operating shaft and bushing – stainless
steel
ɀ Interior parts – sheet steel,
electrogalvanized
ɀ Cover bolts, washers and retractile springs
– stainless steel
Electrical Rating Range:
ɀ Motor starters – NEMA/EEMAC sizes 0-5
Certifications &
Compliances:
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ UL Standards: UL1203 – Hazardous
(classified) Locations
ɀ NEMA: 3,3R,4‡,7BCD,9EFG,12
ɀ CSA Standard: C22.2 No. 30
National Electrical Code is a Registered Trademark of the
National Fire Protection Association.
‡ Enclosure not suitable for NEMA 4 with cover mounted
operators. Breather and drain entries must be plugged for
NEMA 4 rating.
Spectrum EBM motor control enclosures
accommodate popular makes of starters.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:343))
CH0 0 2 C- 3
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
343
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0344-3 Name: 2C-344
100:
DATE: JAN 19 2006
Time: 5:18:15 PM Operator: RB
EBMS Magnetic Line Starters
and Enclosures
2C
Options
COLOR: CMYK
TCP: 15001
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4‡,7BCD,9EFG,12
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
Catalog Number System Example
The following options are available from the
factory by adding suffix to catalog number.
Suffixes are added alphanumerically.
EBMS1FB-(A)-W6413-(B)
(A) Options in this position are additions to
the enclosures and should be listed
alphanumerically.
(B) Options in this position are modifications
to the motor starter and should be listed
alphanumerically.
Description
ɀ Less Overload Relays (lighting contactor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suffix to be
added to
Cat. No.
CL
Position
in Cat.
No.
A
ɀ Less overload relays (motor contactor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CM
A
ɀ Control Circuit Transformer, 100VA for NEMA/EEMAC sizes 0-2, 600/480/240-120, 50/60 Hertz, with
provision for fusing both primary leads and one secondary lead (fuses not included) . . . . . . . . . . . . . . . . . . . .
FTPS100
A
FTPS200
A
FTPS300
J1 1
A
A
ɀ Control Circuit Transformer, 200VA for NEMA/EEMAC size 3, 600/480/240-120, 50/60 Hertz, with provision
for fusing both primary leads and one secondary lead (fuses not included) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Control Circuit Transformer, 300VA for NEMA/EEMAC size 4, 5 600/480/240-120, 50/60 Hertz, with
provision for fusing both primary leads and one secondary lead (fuses not included) . . . . . . . . . . . . . . . . . . . .
ɀ Pilot Light, 120VAC, Red Jewel, w/blank indicating plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Pilot Light, 120VAC, Green Jewel, w/blank indicating plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J3 1
A
ɀ Less Heaters in Starter Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Start-Stop Pushbuttons (requires 2 spaces) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
PB23 1 ‡
B
A
ɀ On-Off Selector Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RR2 1‡
A
ɀ Hand-Off-Auto Selector Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Space Heater, 120 Volt, 25 Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RR3 1 ‡
R11
A
A
ɀ Space Heater, 240 Volt, 25 Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
R22
A
ɀ Space Heater, 480 Volt, 25 Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Automatic Reset Overload Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
R44
S1
A
A
ɀ Std. Drain, Class I, B,C&D; Class II, EF&G; Class III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S756‡
A
ɀ Std. Breather & Drain, Class I, B,C&D; Class II, EF&G; Class III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Side Conduit Entrances (check factory for application) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S756V‡
S366
A
A
ɀ Back Conduit Entrances (check factory for application) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S367
A
ɀ External Epoxy Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Internal and External Epoxy Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ Additional control contacts, N.O. or N.C. – for single speed, non-reversing starters only (number limited by
design of starter. Details on specific makes and sizes on request.)
Aux. Contacts on starter 1 N.O. & 1 N.C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aux. Contacts on starter 2 N.O. & 2 N.C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aux. Contacts on starter 3 N.O. & 3 N.C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Point Term. Block – 30 Amp, 300V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ɀ General Purpose Control Relay, 4 Pole N.O., contacts rated 10A @ 600V, coil 120VAC, 50-60 Hz . . . . . . . . .
S752
S753
A
A
S781
S782
S783
S786
S787*
B
B
B
A
A
1 When specifying non-standard markings on any one of the following options with Spectrum EBM TM Motor Controls (J1, J3, PB23, RR2, RR3) it
is necessary to order DSL Legend Plates for identification and marking of the device(s) being used. See page 329 for DSL Legend Plate listings.
* Use this option with NEMA/EEMAC Size 0 or 1 starters necessitates a larger enclosure. Use ‘‘B’’ size enclosure.
Example:
W/O
Starter
Enclosure
Cat. No.
EBMSFA
Enclosure for
S787
EBMSFB
‡ Enclosure not suitable for NEMA 4 with cover
mounted operators. Breather and drain entries must
be plugged for NEMA 4 rating.
344
STIBOINFO((CRH:66008com:2C:344))
CH0 0 2 C- 4
Typedriver Name: TS name csm no.: 100
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0345-2 Name: 2C-345
100:
DATE: JAN 19 2006
Time: 5:18:15 PM Operator: JB
EBMS Magnetic Line Starters
and Enclosures
Single-Speed Non-Reversing
3-Pole 60 hertz, 600 VAC Maximum
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4 ‡,7BCD,9EFG,12
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
2C
Ordering Information:
ɀ To order an enclosure complete with motor
starter, insert the manufacturer’s symbol in
the designated position (see ‡) of the catalog
number. Symbols are shown in the footnotes.
ɀ Also specify HP, voltage, frequency, RPM,
type and full load ampere rating of motor – or
specify ampere rating of heaters.
ɍɍ Motor starters are furnished with three
heaters when heater ratings are fully
specified.
ɀ Enclosures without starters may be
ordered. Select from the listings below. For
catalog numbers of manufacturers motor
starters that can be accommodated see
Section 6C of this catalog.
EBMS Series Enclosures for Magnetic Line Starters
Single Speed Non-Reversing
Motor Starter
Max. HP
Polyphase
Volts
NEMA
Size
Enclosure
Without
Starter
Cat. No.
With
Starter
Cat. No. ɍɍ
2
120
0
EBMSFA
EBMS0FA-*613
3
3
120
240
1
0
EBMSFA
EBMSFA
EBMS1FA-*613
EBMS0FA-*623
5
5
480
600
0
0
EBMSFA
EBMSFA
EBMS0FA-*643
EBMS0FA-*663
71⁄2
71⁄2
120
240
2
1
EBMSFB
EBMSFA
EBMS2FB-*613
EBMS1FA-*623
10
10
480
600
1
1
EBMSFA
EBMSFA
EBMS1FA-*643
EBMS1FA-*663
15
15
120
240
3
2
EBMSFH
EBMSFB
EBMS3FH-*613
EBMS2FB-*623
25
25
480
600
2
2
EBMSFB
EBMSFB
EBMS2FB-*643
EBMS2FB-*663
30
240
3
EBMSFH
EBMS3FH-*623
50
50
50
480
600
240
3
3
4
EBMSFH
EBMSFH
EBMSFH
EBMS3FH-*643
EBMS3FH-*663
EBMS4FH-*623
100
100
100
480
600
240
4
4
5
EBMSFH
EBMSFH
EBMSFL
EBMS4FH-*643
EBMS4FH-*663
EBMS5FL-*623
200
200
480
600
5
5
EBMSFL
EBMSFL
EBMS5FL-*643
EBMS5FL-*663
EBMS Series starter enclosures are available
with magnetic line starters. NEMA sizes 0-5.
‡ Enclosure not suitable for NEMA 4 with cover mounted
operators. Breather and drain entries must be plugged for
NEMA 4 rating.
* Motor starters:
Manufacturer
Allen Bradley
Square D
General Electric
Cutler-Hammer
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:345))
CH0 0 2 C- 5
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Symbol
AB
D
G
W
345
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0346-1 Name: 2C-346
DATE: JAN 19 2006
Time: 5:19:22 PM Operator: RB
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4‡,7BCD,9EFG,12
EBMS Magnetic Line Starters
and Enclosures
2C
COLOR: CMYK
Dimensions
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
Single-Speed Non-Reversing Sizes 0, 1, 2, 3, 4 and 5 Starters
Dimensions are approximate, not for construction purposes.
Enclosure
Only
Cat. No.
Enclosure
Size
Symbol
A
B
C
D
E
F
G
**J
Conduit Entry
Trade Size
D&Tɍ w/RE
K
L
M
N
O
1.5⍯
3.25
3.13
10.25
—
—
2⍯
1.5⍯
3.25
3.13
10.25
—
—
3⍯
3⍯
2.5⍯
2.5⍯
3.25
3.25
3.13
3.94
10.25
11.66
—
—
—
—
3.25
4.00
3.00
3.50
10.78
13.03
—
41.50
—
18.00
Size 0,1
FVNR
Starter§ EBMSFA
A
18.25 17.25 19.00
6.00 12.63 14.38 12.13
2⍯
Size 2
FVNR
Starter EBMSFB
B
25.75 24.75 26.50
6.00 12.63 14.38 12.13
Size 3,4
FVNR EBMSFD***
Starter EBMSFH
D
H
28.25 27.25 29.00
37.50 36.50 38.25
6.00 12.63 14.06 12.13
6.00 14.25 16.00 13.54
Size 5
FVNR EBMSFK***
K
43.12 41.50 42.25 12.00 17.25 19.88 11.00 (2) 3⍯ (2) 2.5⍯
Starter EBMSFL
L
53.25 51.50 52.88 12.00 17.50 20.18 15.00 (2) 4⍯ (2) 3.5⍯
§ Use EBMSFB enclosure when S787 option is ordered with size 0 or 1 starter.
* 1⍯ Drilled & Tapped conduit entry for control conductors supplied with PLG plug (top & bottom)
** Conduit entrance for power conductors (top and bottom). (All conduit entrances supplied with RE reducer and PLG plug.)
*** For Cutler-Hammer W200 Advantage starters.
®
ɍ Drilled & Tapped.
‡ Enclosure not suitable for NEMA 4 with cover mounted operators. Breather and drain entries must be plugged for NEMA 4 rating.
346
STIBOINFO((CRH:66008com:2C:346))
CH0 0 2 C- 6
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0347-3 Name: 2C-347
DATE: JAN 19 2006
Time: 5:19:23 PM Operator: RB
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4‡,7BCD,9EFG,12
Spectrum TM EBM Enclosures
Supplied with Cutler-Hammer
Advantage TM Starters
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
2C
Application:
Spectrum EBM-E series of hinged cover
motor control enclosures are used:
ɀ for general motor control – indoors and
outdoors – in damp, wet, dirty, dusty
hazardous locations without the need for a
protective shelter.
ɀ in areas where frequent washdowns are
necessary or where heavy rain or water spray
is prevalent.
ɀ for across-the-line starting and stopping of
polyphase ac induction motors.
ɀ to provide motor overload and
undervoltage protection.
ɀ on switchracks or other assemblies where
it’s desired that motor control be centrally
located.
Features:
ɀ Total compliance to the wiring end room
requirements of the National Electrical Code®
1993.
ɀ Solid state electronic Cutler-Hammer
Advantage TM starter.
ɀ Smaller enclosures required than for
conventional starter applications.
ɀ Elimination of heater elements, contact
chatter, and welding due to low voltage
supply.
ɀ Precise overcurrent protection and
constant coil power.
ɀ Same performance and labor-saving
benefits from the versatile Spectrum EBM
Enclosure product line.
ɀ Universal mounting plates and hardware for
all major manufacturers’ components.
ɀ Mercury switch electronic overload reset.
ɀ Optional EMPS control devices may be
added to enclosure cover.
Spectrum EBM-E Series Combination Line Starter with Advantage Starter shown.
Circuit breakers not provided in EBMS series.
Options: (Starter only)
See page 344 for options for the EBM enclosures supplied with Cutler-Hammer Advantage
starters. The following suffixes cannot be ordered with this style equipment: 0, S1.
Standard Materials:
ɀ Body and cover – copper-free aluminum
ɀ Operating handle – copper-free aluminum
ɀ Operating shafts and bushings – stainless
steel
ɀ Interior parts – sheet steel,
electrogalvanized
ɀ Cover bolts, washers, and rectractile
springs – stainless steel
Electrical Rating Ranges:
ɀ Motor starters – NEMA sizes 1-5
Certifications and
Compliances:
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups B,C,D
Class II, Division 1, Groups E,F,G,
Class II, Division 2, Groups F,G
Class III
ɀ UL Standards: UL1203 – Hazardous
(classified) locations
ɀ CSA Standard: C22.2 No. 30
ɀ NEMA: 3, 3R, 4 ‡, 7BCD, 9EFG, 12
‡ Enclosure not suitable for NEMA 4 with cover mounted
operators. Breather and drain entries must be plugged for
NEMA 4 rating.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:347))
CH0 2 C- 1 5
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
347
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0348-1 Name: 2C-348
2C
100:
DATE: JAN 19 2006
Time: 5:19:24 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 1 & 2, Groups B,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,3R,4‡,7BCD,9EFG,12
Spectrum TM EBM Enclosures
Supplied with Cutler-Hammer
Advantage TM Starters
Dimensions (inches):
Ordering Information – Starters
ɀ To order an enclosure, determine the electrical requirements of the
system and locate the corresponding catalog number from the chart
below.
ɀ Enclosures can be ordered without starters, universal mounting plates
with templates will still be provided.
EBM ‘‘E’’ Series Enclosures for Cutler-Hammer Advantage Starters
Single Speed, Non-Reversing
- EBMCFM-E
- EBMCFK-E
Dimensions are approximate, not for construction purposes.
Motor Starter
Max. HP
Polyphase
Volts
71⁄2
240
10
480
10
600
15
240
25
480
25
600
30
240
50
240
50
480
50
600
100
240
100
480
100
600
200
480
200
600
NEMA
Size
1
1
1
2
2
2
3
4
3
3
5
4
4
5
5
Enclosure
Without
Starter
Cat. #‡
EBMSFA-E
EBMSFA-E
EBMSFA-E
EBMSFA-E
EBMSFA-E
EBMSFA-E
EBMSFD-E
EBMSFD-E
EBMSFD-E
EBMSFD-E
EBMSFK-E
EBMSFD-E
EBMSFD-E
EBMSFK-E
EBMSFK-E
With
Starter
Cat. #
EBMS1FA-W6213-E
EBMS1FA-W6413-E
EBMS1FA-W6613-E
EBMS2FA-W6213-E
EBMS2FA-W6413-E
EBMS2FA-W6613-E
EBMS3FD-W6213-E
EBMS4FD-W6213-E
EBMS3FD-W6413-E
EBMS3FD-W6613-E
EBMS5FK-W6213-E
EBMS4FD-W6413-E
EBMS4FD-W6613-E
EBMS5FK-W6413-E
EBMS5FK-W6613-E
‡ Note: ‘‘Enclosures only’’ are supplied with necessary operators, linkages, and mercury switch
electronic overload resets.
DIMENSIONS (inches)
Enclosure
**J Conduit Entry
Only
Dimensions
Trade Size
Cat. No.
A
B
C
D
F
G
D&Tɍ
w/RE
K
L
EBMSFA-E
18.25
17.25
19.40
6.00
14.78
12.13
2⍯
1.5⍯
3.25
3.13
EBMSFD-E
28.25
27.25
29.40
6.00
14.46
12.13
3⍯
2.5⍯
3.25
3.13
EBMSFK-E
43.12
41.50
42.65
12.00
20.58
15.00
(2) 3⍯
(2) 2.5⍯
2.50
3.00
‘‘H‘‘ – Use 1⁄2⍯ diameter bolts for all enclosures listed above.
* 1’’ Drilled & Tapped conduit entry for control conductors supplied with PLG plug (top & bottom).
** Conduit entrance for power conductors (top & bottom). (All conduit entrances supplied with RE reducer and PLG plug.)
ɍ Drilled & Tapped.
‡ Enclosure not suitable for NEMA 4 with cover mounted operators. Breather and drain entries must be plugged for NEMA 4 rating.
348
STIBOINFO((CRH:66008com:2C:348))
CH0 2 C- 1 6
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0349-8 Name: 2C-349
DATE: JAN 19 2006
Time: 5:19:25 PM Operator: GK COLOR: CMYK
EPC Magnetic Line Starters and
Enclosures
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,4,7CD,9EFG,12
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
2C
Application:
EPC magnetic line starters and enclosures
are used:
ɀ for across-the-line starting of polyphase ac
induction motors
ɀ in locations, made hazardous, due to the
presence of flammable vapors, gases or
highly combustible dusts
ɀ in damp, wet or corrosive locations
ɀ indoors or outdoors at petroleum refineries,
chemical and petrochemical plants and other
process industry facilities where similar
hazards exist
ɀ to provide motor running protection,
undervoltage protection, and remote starting
and stopping
Features:
ɀ Quick-opening covers – less than two turns
to remove or install
ɀ Three section design for ease of installation
ɀ Water-shedding construction with female
threads on top cover, male threads on
bottom cover, and top cover skirted
ɀ Specially located stops and locks ensure
adequate thread engagement and prevent
overtightening
ɀ Separate replaceable mounting bracket
attached to the rear of the body provides
three-point suspension for quick installation
and leveling – one keyhole slot at top and two
open slots at bottom
ɀ Bodies have two taper tapped conduit hubs
with integral bushings on the top, and two
more directly below
ɀ Universal mounting plate and reset
mechanism will accommodate any of the
motor starters in catalog listing
ɀ When interior mounting plate is removed,
line and load conductors are easily pulled
into the wiring chamber. The interior
assembly with starter attached is then
replaced, final connections made, and covers
assembled
ɀ Furnished with third overload relay as
standard
Standard Materials:
ɀ Bodies and covers – copper-free aluminum
ɀ Reset handle – copper-free aluminum
ɀ Reset shaft – stainless steel
ɀ Interior parts – stainless steel
Standard Finishes:
ɀ Copper-free aluminum – natural
ɀ Stainless steel – natural
ɀ Sheet steel – electrogalvanized with
chromate finish
Electrical Rating Ranges:
Certifications &
Compliances:
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Cl. III
ɀ NEMA/EEMAC: 3, 4, 7CD, 9EFG, 12
ɀ UL Standard: 698
ɀ CSA Standard: C22.2 No. 30
Options:
ɀ The following special options are available
from factory by adding suffix to Cat. No. and
many are available in kit form for field
addition to existing units:
See page 352 for listing of kits
Suffix to be
Added to Encl.
Description
Cat. #
Control circuit transformer 600/480/240-120 volts, 50 or 60 hertz (Sizes 0 and 1 – 50VA, 100VA,
Size 2 – 100VA-200VA)
Fusible – Secondary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FT
Primary and secondary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FTPS
Automatic reset overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S1
Less overload relays (lighting contactor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL
Less overload relays (motor contactor). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CM
Auxiliary Contacts:*
1NO/1NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S781
2NO/2NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S782
3NO/3NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S783
Pilot light holes drilled, tapped and plugged for future addition of pilot lights –
one hole . . . . . . . . . . . . S541
two holes . . . . . . . . . . . S542
Side bosses drilled and tapped same size as standard hubs . . . . . . . . . . . . . . . . . . . . . . . . . . S366
Back boss drilled and tapped same size as standard hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . S367
Standard Breather (Cl. I, Groups C,D; Cl. II, Groups E,F,G; Cl. III) . . . . . . . . . . . . . . . . . . . . . . S219
Standard Drain (Cl. I, Groups C,D; Cl. II, Groups E,F,G; Cl. III) . . . . . . . . . . . . . . . . . . . . . . . . . S198
Standard Breather and Drain (Cl. I, Groups C,D; Cl. II, Groups E,F,G; Cl. III) . . . . . . . . . . . . S198V
Universal Breather-Drain (Cl. I, Groups C,D; Cl. II, Groups F,G) . . . . . . . . . . . . . . . . . . . . . . . S454‡
(2) Universal-Breather Drains (Cl. I, Groups C,D; Cl. II, Groups F,G) . . . . . . . . . . . . . . . . . . S454V‡
Pushbuttons (heavy duty):
START-STOP . . . . . . . . . . . . . . . . . . . . . . . PB3‡
Selector switches (standard duty):
ON-OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . RR2‡
HAND-OFF-AUTO . . . . . . . . . . . . . . . . . . . RR3‡
Pilot lights:
Red, 120 volt . . . . . . . . . . . . . . . . . . . . . . . . . . . J1
Green, 120 volt. . . . . . . . . . . . . . . . . . . . . . . . . J3
Pilot light transformers:
240 volt† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T2
480 volt† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T4
600 volt† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T5
Space heaters:
120 volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R11
240 volt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R22
480 volt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R44
ɀ Starter Sizes 0 to 2 inclusive
* Application limited by starter or contactor design – consult
factory
† Required for pilot lights on other than 120 volt control
circuits. One required for each lamp
‡ Not suitable for NEMA 4
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:349))
CH0 0 2 C- 7
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
349
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0350-6 Name: 2C-350
2C
DATE: JAN 19 2006
Time: 5:19:26 PM Operator: JB
EPC Magnetic Line Starters and
Enclosures
COLOR: CMYK
TCP: 15001
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,4,7CD,9EFG,12
Dimensions (inches)*
Single-Speed Non-Reversing Sizes 0, 1, and 2 Starters
Cat. #
EPC
Int. Dia.
a
b
c
d
e
f
g
h
j
k
l
m
n
p
97-FT
97-FTPS
7⍯
Dimensionsɍ
105⁄8
2413⁄16
3713⁄16
1411⁄16
113⁄4
711⁄16
53⁄8
9
4
73⁄8
21⁄16
93⁄8
51⁄4
11⁄4
97
7⍯
Dimensions
105⁄8
1913⁄16
2513⁄16
1411⁄16
63⁄4
711⁄16
53⁄8
2
4
73⁄8
21⁄16
93⁄8
51⁄4
11⁄4
ɍ For units with Control Circuit Transformer (suffix FT
or FTPS)
* Dimensions are approximate, not for construction
350
STIBOINFO((CRH:66008com:2C:350))
CH0 0 2 C- 8
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0351-3 Name: 2C-351
DATE: JAN 19 2006
Time: 5:19:27 PM Operator: RB
EPC Magnetic Line Starters and
Enclosures
Single-Speed Non-Reversing
3-Pole 60 hertz, 600VAC Maximum
Ordering Information:
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,4,7CD,9EFG,12
Motor Starter
To order an enclosure complete with starter,
insert the manufacturer’s symbol in the
designated position of the catalog number.
Symbols are shown in the footnote at the
bottom of this page. Specify hp, voltage,
frequency, rpm, type and full load ampere
rating of motor – or specify ampere rating of
heaters. ɍɍ Starters are furnished with three
heaters when heater ratings are fully
specified.
Enclosures only can be ordered. Select from
listings. For starters that can be
accommodated see Table 1 in Section 6C.
Detailed information on starter and heater
selection is given in Section 6C.
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Watertight
2C
Enclosure
Volts
120
NEMA/EEMAC
Size
0
Hub
Size
11⁄4
Int.
Dia.
7
Without
Starter
Cat. #
EPC97
With
Starter
Cat. # ɍɍ
EPC970-†613
3
3
120
240
1
0
11⁄4
11⁄4
7
7
EPC97
EPC97
EPC971-†613
EPC970-†623
5
5
480
600
0
0
11⁄4
11⁄4
7
7
EPC97
EPC97
EPC970-†643
EPC970-†653
71⁄2
240
1
11⁄4
7
EPC97
EPC971-†623
10
10
480
600
1
1
11⁄4
11⁄4
7
7
EPC97
EPC97
EPC971-†643
EPC971-†653
Max. HP
Polyphase
2
† Motor Starters:
Manufacturer
Allen-Bradley
General Electric
Square D
Cutler-Hammer
Symbol
AB
G
D
W
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:351))
CH0 0 2 C- 9
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
351
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0352-1 Name: 2C-352
2C
DATE: JAN 19 2006
Time: 5:19:28 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Special Feature Kits
For EPC Enclosures
Pushbutton Station
and Selector
Switch Kits
Pilot
Light Kits
EPC magnetic line starter and EPC
combination line starter enclosures are
provided as standard with switch operating
shaft holes drilled, tapped and plugged.
Pushbutton stations and selector switches
can be assembled in these enclosures in the
field, using kits listed below.
When EPC magnetic line starter and EPC
combination line starter enclosures have
been ordered with pilot light holes drilled,
tapped and plugged (Cat. No. suffix S541 and
S542), pilot lights can be assembled in the
field, using kits listed below.
Description
Applies to
Cat. #
Pilot light assembly less transformer
7⍯, 9⍯, 11⍯ EPC
EMP015-J†-KIT
Pilot light assemblies with transformer and
transformer mounting strap (for single pilot
light) suffix S541
7⍯ EPC only
9⍯ EPC only
11⍯ EPC only
EPC87-J†-T†-KIT
EPC892-J†-T†-KIT
EPC813-J†-T†-KIT
2 pilot light assemblies with 2 transformers
and transformer mounting strap (for double
pilot light) suffix S542
7⍯ EPC only
9⍯ EPC only
11⍯ EPC only
EPC87-J†-J†-T†-KIT
EPC892-J†-J†-T†-KIT
EPC813-J†-J†-T†-KIT
Applies to 7⍯, 9⍯, 11⍯ EPC
Description
Cat. #
START-STOP pushbutton
station assembly
EPC-PB3-KIT
Replacement pushbutton
station only for
EPC-PB3-KIT
16320-N
ON-OFF selector switch
assembly (2 position)
EPC-RR2-KIT
Replacement pilot light transformer only
(240V primary)
All units
15129-A
Replacement
switch only for
EPC-RR2-KIT
ESWP126
Replacement pilot light transformer only
(480V primary)
All units
15130-A
Replacement pilot light transformer only
(600V primary)
All units
15131-A
HAND-OFF-AUTO selector
switch assembly
(3 position)
EPC-RR3-KIT
Replacement
switch only for
EPC-RR3-KIT
ESWP126
† Insert color symbol from table below and add primary
voltage symbol (T2 for 240, T4 for 480 or T5 for 600 volts).
Example: EPC87-J†-J†-T†-KIT with red and green pilot lights
for 480 volts is EPC-J1-J3-T4-KIT.
352
STIBOINFO((CRH:66008com:2C:352))
CH0 2 C- 1 0
US: 1-866-764-5454
CAN: 1-800-265-0502
Color
Symbol
Color
Symbol
Red
Green
Amber
J1
J3
J6
Clear
Blue
J10
J11
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0353-6 Name: 2C-353
DATE: JAN 19 2006
Time: 5:19:29 PM Operator: GK COLOR: CMYK
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7CD,9EFG,12
EMN Manual Line Starters
and Enclosures
600VAC Maximum
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
2C
Application:
EMN manual line starters and enclosures are
used:
ɀ for manual across-the-line starting of single
and polyphase ac motors
ɀ to provide motor running protection and
manual starting and stopping
ɀ in locations made hazardous due to the
presence of flammable vapors, gases, or
high combustible dusts
ɀ for installation in petroleum refineries,
chemical and petrochemical plants, and
other process industry facilities
ɀ in damp, wet, or corrosive locations
Features:
ɀ Compact, rectangular enclosure makes
optimum use of internal space
ɀ Operating handle may be padlocked in
either ‘‘ON’’ or ‘‘OFF’’ position
ɀ Compact design allows installation in area
where space is limited
ɀ Furnished with drilled and tapped conduit
openings
ɀ Polyphase manual starters are furnished
with third overload relay as standard
Standard Materials:
Ordering Information:
Specify hp, voltage, frequency, number of
phases, rpm, type and full load ampere rating
of motor – or specify ampere rating of
heaters.
ɀ Bodies, covers and toggle operator –
copper-free aluminum
ɀ Operating shaft – stainless steel
ɀ Internal operating bail – sheet steel or
aluminum
Motor Starter
NEMA
Size
Poles
(Phase)
Max. AC HP Ratings
208/
115V
240V
Standard Finishes:
M-0
M-1
M-1P
M-0
2 (1PH)
2 (1PH)
2 (1PH)
3 (3PH)
3 (1PH)
3 (3PH)
1
2
3
2
2
3
ɀ Copper-free aluminum – natural
ɀ Stainless steel – natural
ɀ Sheet steel – electrogalvanized with
chromate finish
Electrical Rating Ranges:
M-1
2
3
5
3
3
71⁄2
ɀ Starter sizes 0, 1, 1P
Enclosure Without Starter
Certifications &
Compliances:
Starter Manufacturer
Enclosure
Cat. #§
Cutler-Hammer
EMN24
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ NEMA/EEMAC: 3, 7CD, 9EFG, 12
ɀ UL Standard: 698
ɀ CSA Standard: C22.2 No. 14
Two pole starters require one heater; three
pole starters have three heaters. See page
446 for starter and heater selection. For
starter Cat. No. refer to Table 3 in Section 6C.
480/
600V
Enclosure
With
Starter
Cat. #
5
EMN24-W20
EMN24-W21
EMN24-W21P
EMN24-W30
10
EMN24-W31
Dimensions* (inches)
Options:
ɀ The following special options are available
from factory by adding suffix to Cat. #:
Suffix to be Added to Encl.
Description
Cat. #
Standard Breather (Cl. I, Groups C,D;
Cl. II, Groups E,F,G; Cl. III) . . . . . . . . . . . . S219
Standard Drain (Cl. I, Groups C,D;
Cl. II, Groups E,F,G; Cl. III) . . . . . . . . . . . . S198
Standard Breather and Drain (Cl. I,
Groups C,D; Cl. II, Groups E,F,G;
Cl. III) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S198V
Universal Breather-Drain (Cl. I,
Groups C,D; Cl. II, Groups F,G). . . . . . . . S454
(2) Universal Breather-Drains (Cl. I,
Groups C,D; Cl. II, Groups F,G) . . . . . . S454V
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:353))
CH0 2 C- 1 1
§ Enclosures are furnished with two 11⁄4⍯ drilled and
tapped openings with 11⁄4⍯ to 1⍯ reducers.
* Dimensions are approximate, not for construction
purposes.
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
353
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0354-2 Name: 2C-354
2C
100:
DATE: JAN 19 2006
Time: 5:19:30 PM Operator: JB
EFD Manual Motor Starting
Switches and Enclosures
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7B*CD,9EFG,12
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Application:
EFD manual motor starting and stopping
switch enclosures are used:
ɀ for manual starting of small ac or dc motors
ɀ in locations, made hazardous, due to the
presence of flammable vapors, gases or
highly combustible dusts
ɀ for installation at petroleum refineries,
chemical and petrochemical plants and in
other process industry facilities where similar
hazards exist
Features:
ɀ Enclosure is small and compact
ɀ Accurately ground flange on both body and
cover for flame-tight joint
ɀ Switch can be padlocked in either ‘‘ON’’ or
‘‘OFF’’ positions
ɀ Dead end (EFD) or through feed (EFDC)
hubs in 3⁄4⍯ to 1⍯ size
EFD dead end
EFDC through feed
Standard Materials:
ɀ Bodies and covers – Feraloy® iron alloy
ɀ Operating handle – type 6/6 nylon
ɀ Operating shaft – stainless steel
Standard Finishes:
ɀ Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Type 6/6 nylon – natural (black)
ɀ Stainless steel – natural
Certifications and
Compliances:
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups B*,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ NEMA: 3, 7B*CD, 9EFG, 12
ɀ UL Standard: 698
ɀ CSA Standard: C22.2 No. 30
Without Overload Protection
With Switches
Poles
Cat. #
2
Square D
Class 2510
Type KO-1
GE-TC2368S
3
Poles
2
3
HP
115VAC
1
3⁄4
1
3⁄4
1
With
Switch
Cat. #
EFD218-T8
EFD318-T8
EFD2419
EFD3419
Dimensions (inches)
Poles
Hub
Size
2
3⁄4
3
3⁄4
1
1
conduit opening for Group B usage.
STIBOINFO((CRH:66008com:2C:354))
CH0 2 C- 1 2
CAN: 1-800-265-0502
With
Switch
Cat. #
EFDC218-T8
EFDC318-T8
EFDC2419
EFDC3419
Dimensions are approximate, not for construction purposes
* Add GB suffix. Seals must be installed within 1-1/2⍯ of each
US: 1-866-764-5454
460-575VAC
3
Through feed
Hub
Size
Hub
Size
3/4
1
354
230VAC
2
30A., 240VAC, 7-1/2 hp
20A., 600VAC, 15 hp
Dead end
Options:
ɀ The following special options are available
from factory by adding suffix to Cat. No.:
Suffix to be
Added to Encl.
Description
Cat. #
For use in Group B Hazardous areas. . . . GB*
Switch Ratings
Amps
250VAC
600VAC
30
20
Copyright© 2006 Cooper Crouse-Hinds
Dim.
‘‘h’’
7/8
1
Dim.
‘‘a’’
13/16
15/16
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0355-5 Name: 2C-355
100:
DATE: JAN 19 2006
Time: 5:19:31 PM Operator: JB
EDS Factory Sealed Manual
Motor Starting Switches and
Enclosures
COLOR: CMYK
TCP: 15001
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7B*CD,9EFG
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
2C
Standard Finishes:
Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural
ɀ Type 6/6 nylon – black
ɀ Stainless steel – natural
Certifications and
Compliances:
EDSC2199
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups B*,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ NEMA/EEMAC: 3,7B*CD,9EFG
ɀ UL Standard: 894, 698
ɀ CSA Standard: C22.2 No. 30
EDS2299
Application:
Factory sealed enclosures are installed in a
rigid metallic conduit system for surface
mounting adjacent to or remote from
equipment being controlled and are used:
ɀ to prevent arcing of enclosed device from
causing ignition of a specific hazardous
atmosphere or atmospheres external to the
enclosure
ɀ in industrial areas such as chemical plants,
oil and gas refineries, paint and varnish
manufacturing plants, gasoline bulk loading
terminals, grain elevators, grain processing
industries, coal processing or handling areas,
or metal handling or finishing areas where
atmosphere may contain hazardous gases
and/or dust
ɀ in non-hazardous areas where sturdy,
durable enclosures are required
ɀ in conjunction with magnetic starters or
contactors for remote control of motors
Manual motor starting switch enclosures are
used:
ɀ for manual starting of small ac or dc motors
ɀ to provide manual starting and stopping
and, in the case of units with heaters, motor
running protection
Options:
Suffix to be
Added to
Cat. #
Description
For use in Group B hazardous areas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GB*
Bodies and covers (single and two gang units) – copper-free aluminum. . . . . . . . . . . . . . . . . . . SA
Standard Materials:
ɀ Bodies – Feraloy® iron alloy (U.S.); copper-free aluminum (Canada).
ɀ Shafts & bushings – stainless steel
ɀ Sealing enclosures – copper-free aluminum
Dimensions (inches)
Features:
Dimensions are approximate, not for construction purposes.
Side Hub Dim. Dim.
View Size ‘‘h’’ ‘‘i’’
7⁄8
13⁄16
3⁄4
15⁄16
1
1
Front View
Factory sealed devices have many distinct
advantages:
ɀ reduce installation problems
ɀ eliminate external seals
ɀ lower installation costs
ɀ improve safety
ɀ mounting lugs and taper tapped hubs with
integral bushings
ɀ large machine screws for fastening covers
to bodies
ɀ lockout hole for padlock having 1⁄4⍯ hasp is
provided
ɀ close tolerances in machining of wide,
mating flanges and journalled shafts and
bearings produce flametightness of
enclosure joints
ɀ dead end (EDS) or through feed (EDSC)
hubs – 3⁄4⍯ or 1⍯ sizes
Single gang
Two gang
Surface covers have
same length and
width as single & 2
gang bodies.
* Seals must be installed within 11⁄2⍯ of each conduit opening in Division 1
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:355))
CH0 2 C- 1 7
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
355
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0356-4 Name: 2C-356
DATE: JAN 19 2006
Time: 5:19:32 PM Operator: RB
With Allen-Bradley
Bulletin 600 Switches
With General
Electric Switches
Maximum HP Ratings
Maximum HP Ratings
Poles
115-230
Volts AC
1
2
1 hp
1 hp
115-230
Volts DC
Cat. #
Poles
115-230
Volts AC
115
Volts DC
3⁄4
A-B BUL 600 TOX4
A-B BUL 600 TOX5
1
2
1 hp
1 hp
1 hp
1 hp
hp
Single Gang
Hub
Poles Size
3⁄4
1
1
3⁄4
2
1
1
2
1
3⁄4
1
Typedriver Name: TS name csm no.: 100
230
Volts DC
1⁄4 hp
1 hp
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cat. #
GE-CR101-Y
GE-CR101-H
Single Gang
Dead
end
Cat. #
EDS2199†
EDS3199†
EDS21100†
EDS31100†
Through
feed
Cat. #
EDSC2199†
EDSC3199†
EDSC21100†
EDSC31100†
EDS2299†
EDS3299†
EDS22100†
EDS32100†
EDSC2299†
EDSC3299†
EDSC22100†
EDSC32100†
Hub
Poles Size
3⁄4
1
1
3⁄4
2
1
Two Gang
3⁄4
TCP: 15001
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7B*CD,9EFG,12
EDS Factory Sealed Manual
Motor Starting Switches and
Enclosures
2C
COLOR: CMYK
Dead
end
Cat. #
EDS21093†
EDS31093†
EDS21094†
EDS31094†
Through
feed
Cat. #
EDSC21093†
EDSC31093†
EDSC21094†
EDSC31094†
EDS22093†
EDS32093†
EDS22094†
EDS32094†
EDSC22093†
EDSC32093†
EDSC22094†
EDSC32094†
Two Gang
1
2
3⁄4
1
3⁄4
1
These heaters are for motors rated 40°C continuously. For motors rated 50°C or 55°C, multiply full load motor current by 0.9 and use this value to
select heaters. Symbol 0 (zero) must be used to indicate heater omitted.
Heater Table (Allen-Bradley)
Max. Motor
Full-Load
Amps
0.17
0.21
0.25
0.32
0.39
0.46
0.57
0.71
0.79
0.87
0.98
1.08
1.19
1.30
1.43
1.58
1.75
1.88
2.13
2.40
2.58
CrouseHinds Symbol
Number
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P21
Max. Motor
Full-Load
Amps
2.92
3.09
3.32
3.77
4.16
4.51
4.93
5.43
6.03
6.83
7.72
8.24
8.9
9.6
10.8
12.0
13.5
15.2
Heater Table (General Electric)
CrouseHinds Symbol
Number
P22
P23
P24
P25
P26
P27
P28
P29
P30
P31
P32
P33
P34
P35
P36
P37
P38
P39
Max. Motor
Full-Load
Amps
.48
.53
.58
.65
.71
.78
.86
.95
1.04
1.14
1.25
1.37
1.49
1.63
1.78
1.95
2.13
2.32
2.53
2.76
CrouseHinds Symbol
Number
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
G17
G18
G19
G20
G21
Max. Motor
Full-Load
Amps
3.01
3.27
3.56
3.88
4.22
4.60
5.00
5.43
5.90
6.41
6.98
7.60
8.25
8.95
9.75
10.6
11.4
12.5
13.6
14.8
16.0
CrouseHinds Symbol
Number
G22
G23
G24
G25
G26
G27
G28
G29
G30
G31
G32
G33
G34
G35
G36
G37
G38
G39
G40
G41
G42
† Includes one interchangeable heater. Select heater from the table below individual listings and use symbol number as second section of the Cat. No. Example: EDS2199-P5. Insert symbol 0
(zero) to omit heater.
* Add GB suffix. Seals must be installed within 11⁄2⍯ of each conduit opening for Group B usage.
356
STIBOINFO((CRH:66008com:2C:356))
CH0 2 C- 1 3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0357-2 Name: 2C-357
100:
DATE: JAN 19 2006
Time: 5:19:32 PM Operator: RB
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
EDS Factory Sealed
Manual Motor Starting
Switches and Enclosures
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
2C
With
Cutler-Hammer Switches
Maximum HP Ratings
120-240
32
120
240
Poles Volts AC Volts DC Volts DC Volts DC Cat. #
1⁄4 hp
1⁄4 hp
1⁄4 hp
WEST-MST01
1
1 hp
1⁄4 hp
1 hp
1 hp
WEST-MST02
2
1 hp
Single Gang
Poles
1
2
Hub
Size
3⁄4
1
3⁄4
1
Dead
end
Cat. #
EDS21101†
EDS31101†
EDS21102†
EDS31102†
Through
feed
Cat. #
EDSC21101†
EDSC31101†
EDSC21102†
EDSC31102†
EDS22101†
EDS32101†
EDS22102†
EDS32102†
EDSC22101†
EDSC32101†
EDSC22102†
EDSC32102†
Two Gang
1
2
3⁄4
1
3⁄4
1
These heaters are for motors rated 40°C continuously. For motors
rated 50°C or 55°C, multiply full load motor current by 0.9 and use this
value to select heaters. Symbol 0 (zero) must be used to indicate
heater omitted.
Heater Table (Cutler-Hammer)
Max. Motor
Full-Load
Amps
CrouseHinds Symbol
Number
Max. Motor
Full-Load
Amps
CrouseHinds Symbol
Number
.43
.48
.53
.58
.64
.71
.78
.87
.95
1.03
1.15
1.27
1.35
1.51
1.67
1.83
1.99
2.23
2.47
2.71
W 1
W 2
W 3
W 4
W 5
W 6
W 7
W 8
W 9
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
2.95
3.27
3.59
3.99
4.39
4.79
5.26
5.83
6.39
7.03
7.74
8.46
9.35
10.30
11.35
12.47
13.67
15.12
16.00
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
† Includes one interchangeable heater. Select heater from the table below individual listings
and use symbol number as second section of the Cat. No. Example: EDS21101-W5. Insert
symbol 0 (zero) to omit heater.
* Add GB suffix. Seals must be installed within 11⁄2⍯ of each conduit opening for Group B
usage.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:357))
CH0 2 C- 1 4
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
357
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0358-2 Name: 2C-358
2C
100:
DATE: JAN 19 2006
Time: 5:19:33 PM Operator: RB
COLOR: CMYK
TCP: 15001
UL/cUL Listed Class I,
Division 2, Groups A, B, C, D
Class I, Zones 1 and 2,
AEx de HB + H2, T5, T6
Class II, Division 1,
Groups E, F, G (cUL)
Explosion Protected
Manual Motor Starters
25 Amp, 690 VAC Non-Metallic
Enclosure
Application
Explosion protected manual motor starters
are used in a metallic conduit or cable
system for surface mounting to protect
motors against overload and phase failure.
Features
ɀ Explosion protected factory sealed circuit
breaker and manual motor starter
ɀ Innovative break-line in cover allows full
wiring access, making installation quick and
easy.
ɀ Switch handle provides clear indication of
switch position
ɀ Lockable handle meets OSHA lockout/
tagout requirements, provision for 3 padlocks
ɀ Large rotary handle provides easy gripping
with gloved hands
ɀ Captive cover screws
Certifications &
Compliances
ɀ UL/cUL Listed
ɀ Class I, Division 2, Groups A, B, C, D
ɀ Class I, Zones 1 and 2, Ex de IIB+H2, T6
ɀ Class II, Division 1, Groups E, F, G (cUL)
ɀ CENELEC - PTB 99-ATEX 1162
ɀ EEx de IIC, T6, Zones 1 and 2.
ɀ IP 66, NEMA 4X
Standard Materials
Enclosure - Fiberglass-reinforced polyester
ɀ Nonmetallic, corrosion resistant
ɀ Increased safety Ex-e protection
ɀ Impact Resistant
ɀ NEMA 4X, IP 66 Protection
ɀ Enclorure meets UL 94-VO
ɀ UV rated
Enclosure Gasket - Silicon
Handle - Impact-resistant thermoplastic
Cover Screws - Stainless steel
Conduit Entries: Zinc Myers Hubs
Brass Mounting plate - Ground continuity
Technical Data
358
STIBOINFO((CRH:66008com:2C:358))
CH0 6 F - 1 6
Type of Protection
(A)Ex ed IIC T5, T6
Rated Voltage
Rated Current
Rated Current, aux. contact
Short Circuit
Under voltage trip
Connection Terminals
Connection terminals, aux. contact
Up to 690 VAC
Up to 25 A
2A
See table on next page
Tripping at 15% - 75% V-rated
Switching - on when V> 80% V-rated
Up to 10mm2
2 × 2.5 mm2
Conduit or Cable entries
2 × 3⁄4⍯ Myers hubs
Weight
5.5 Ibs./ 2.5 Kg.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Typedriver Name: TS name csm no.: 100
CENELEC - PTB 99,
ATEX 1162 CERTIFIED
EEx de IIC, T6, Zones
1 and 2 EEx de IIC,
T6 Zones 21 and 22
IP66, NEMA 4X
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0359-3 Name: 2C-359
100:
DATE: JAN 19 2006
Time: 5:19:34 PM Operator: TB
COLOR: CMYK
25 Amp, 690 VAC Non-Metallic
Enclosures
Typedriver Name: TS name csm no.: 100
CENELEC - PTB 99,
ATEX 1162 CERTIFIED
EEx de IIC, T6, Zones
1 and 2 EEx de IIC,
T6 Zones 21 and 22
IP66, NEMA 4X
UL/cUL Listed Class I,
Division 2, Groups A, B, C, D
Class I, Zones 1 and 2,
AEx de HB + H2, T5, T6
Class II, Division 1,
Groups E, F, G (cUL)
Explosion Protected
Manual Motor Starters
TCP: 15001
2C
Short Circuit Protection
Setting Range
230 VAC
AIC
0.1 A - 1.6 A
1.6 A - 2.5 A
2.5 A - 4.0 A
4.0 A - 6.3 A
6.3 A - 9.0 A
9.0 A - 12.5 A
12.5 A - 16.0 A
16.0 A - 20.0 A
20.0 A - 25.0 A
400 VAC
AIC
500 VAC
AIC
690 VAC
AIC
40
30
30
20
20
20
20
40
10
3
3
3
3
2
2
Short-circuit proof.
No back-up fuse required
50
50
50
50
50
Wiring Diagram
Dimensions (Inches)
Ordering Information:
Setting Range or rated current
0.1 - 0.16 A
0.16 - 0.25 A
0.25 - 0.40 A
0.40 - 0.63 A
0.63 - 1.0 A
1.0 - 1.6 A
1.6 - 2.5 A
2.5 - 4.0 A
4.0 - 6.3 A
6.3 - 9.0 A
9.0 - 12.5 A
12.5 - 16 A
16 - 20 A
20 - 25 A
Catalog Number
GHG 635 1101 L0101
GHG 635 1101 L0102
GHG 635 1101 L0103
GHG 635 1101 L0104
GHG 635 1101 L0105
GHG 635 1101 L0106
GHG 635 1101 L0107
GHG 635 1101 L0108
GHG 635 1101 L0109
GHG 635 1101 L0110
GHG 635 1101 L0111
GHG 635 1101 L0112
GHG 635 1101 L0113
GHG 635 1101 L0114
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:359))
CH0 6 F - 1 6
Accessory Options
1 ⍧ without aux. contact
៑ 2 ⍧ with aux contact 1 NO + 1 NC
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
359
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0360-3 Name: 2C-360
2C
100:
DATE: JAN 19 2006
Time: 5:19:35 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
NEMA 3,4,12
Raintight
Wet Locations
MC Manual Motor Starting
Switches and Enclosures
Application:
MC manual motor starting switches and
enclosures are used:
ɀ for manual starting of small ac and dc
motors of one horsepower or less (see page
361 for ratings)
ɀ in damp, wet or corrosive locations such as
dairies, meat packing plants, chemical plants
and outdoor locations
ɀ to provide motor running protection and
manual starting and stopping
Features:
ɀ Enclosure is compact and gasketed to
meet NEMA/EEMAC 4 requirements for
watertightness
ɀ Switch can be padlocked in either the ‘‘ON’’
or ‘‘OFF’’ positions
ɀ Provided with dead end (MC) or throughfeed (MCC) hubs – 1⁄2⍯ and 3⁄4⍯ sizes – with
mounting feet
MC dead end
MCC through feed
Standard Materials:
ɀ Body and cover – Feraloy® iron alloy
ɀ Operating handle – copper-free aluminum
ɀ Operating shaft – stainless steel
Standard Finishes:
ɀ Feraloy – electrogalvanized and aluminum
acrylic paint
ɀ Copper-free aluminum – natural
ɀ Stainless steel – natural
Certifications and
Compliances:
Dimensions (inches)*
ɀ NEMA/EEMAC: 3, 4, 12
ɀ UL Standard: 508
ɀ CSA Standard: C22.2 No. 14
Hub
Size
a
b
360
STIBOINFO((CRH:66008com:2C:360))
CH0 0 2 C- 1
US: 1-866-764-5454
1⁄2
3⁄4
7⁄8
7⁄8
5⁄8
3⁄4
CAN: 1-800-265-0502
* Dimensions are approximate, not for construction purposes.
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0361-2 Name: 2C-361
100:
DATE: JAN 19 2006
Time: 5:19:36 PM Operator: RB
MC Manual Motor Starting
Switches and Enclosures
Poles
1
2
TCP: 15001
2C
These heaters are for motors rated 40°C
continuously. For motors rated 50°C or 55°C,
multiply full load motor current by 0.9 and use
this value to select heaters. Symbol 0 (zero)
may be used to indicate heater omitted.
Cat. #
MST01
MST02
Heater Table
Full
Load
Maximum
Horsepower Ratings
Volts
120/240 AC
32 DC
120/240 DC
240 DC
1-Pole
1
1⁄4
Motor
Current
2-Pole
1
1⁄4
1
.40 — .43
.44 — .48
.49 — .53
.54 — .58
.59 — .64
.65 — .71
.72 — .78
.79 — .87
.88 — .95
.96 — 1.03
1.04 — 1.15
1.16 — 1.27
1.28 — 1.35
1.36 — 1.51
1.52 — 1.67
1.68 — 1.83
1.84 — 1.99
2.00 — 2.23
2.24 — 2.47
2.48 — 2.71
2.72 — 2.95
2.96 — 3.27
3.28 — 3.59
3.60 — 3.99
4.00 — 4.39
4.40 — 4.79
4.80 — 5.26
5.27 — 5.83
5.84 — 6.39
6.40 — 7.03
7.04 — 7.74
7.75 — 8.46
8.47 — 9.35
9.36 — 10.30
10.31 — 11.35
11.36 — 12.47
12.48 — 1.367
13.68 — 15.12
15.13 — 16.00
1⁄4
MC
Single Gang (Dead End)
Poles
1
1
2
2
Hub
Size
1⁄2
3⁄4
1⁄2
3⁄4
Enclosure
With
Switch
Cat. #
MC1211†
MC2211†
Without
Switch
Cat. #
MC1212B
MC2212B
MC1212†
MC2212†
MC1212B
MC2212B
MCC
Single Gang (through feed)
Poles
1
1
2
2
Hub
Size
1⁄2
3⁄4
1⁄2
3⁄4
Enclosure
With
Switch
Cat. #
MCC1211†
MCC2211†
Without
Switch
Cat. #
MCC1212B
MCC2212B
MCC1212†
MCC2212†
MCC1212B
MCC2212B
Typedriver Name: TS name csm no.: 100
NEMA 3,4,12
Raintight
Wet Locations
MC Manual Motor
Starting Switches
Manufacturer
Cutler-Hammer
Cutler-Hammer
COLOR: CMYK
Heater
Rating
.50
.55
.61
.67
.74
.81
.89
.98
1.10
1.20
1.30
1.45
1.60
1.70
1.90
2.10
2.30
2.50
2.80
3.10
3.40
3.70
4.10
4.50
5.00
5.50
6.00
6.60
7.30
8.00
8.80
9.70
10.60
11.70
12.90
14.20
15.60
17.10
18.60
Cooper CrouseHinds
Symbol
Number
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
† Includes one interchangeable heater. Select heater from
table above and use symbol number as second section of
the Cat. No.
Example: MC1211-W5
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:361))
CH0 0 2 C- 2
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
361
Zoom: 100
Download