EBMC Combination Line Starters and Enclosures Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 Explosionproof Dust-ignitionproof Raintight Wet Locations Watertight 1C Applications: Features: tø3VHHFEDPSSPTJPOSFTJTUBOUDBTUDPQQFSGSFFBMVNJOVN construction (less than 0.4 of 1%) tø$PNQPOFOUPQFSBUJOHIBOEMFTMPDBUFEUISPVHIUIFSJHIUTJEFXBMM PGUIFCPEZQFSNJUTWJTVBMDPOGJSNBUJPOPGDPSSFDUDPNQPOFOU BTTFNCMZBOEPQFSBUJPO tø5PUBMDPNQMJBODFUPUIFXJSJOHFOESPPNSFRVJSFNFOUTPGUIF National Electrical Code*/Canadian Electrical Code tø4FNJDMBNTIFMMFODMPTVSFEFTJHOXJUIBOFYUFSOBMGMBOHFEHSPVOE KPJOUCFUXFFOCPEZBOEDPWFSNBLFTJOUFSJPSDPNQPOFOUTNPSF BDDFTTJCMF tø.JOJNVNFODMPTVSFUPFODMPTVSFTQBDJOHXJUIMJUUMFJOUFSGFSFODF CFUXFFOUIFPQFOFEDPWFSBOEBOBEKBDFOUFODMPTVSF tø4UBJOMFTTTUFFMIJOHFTBMMPXUIFDPWFSUPTXJOHXFMMPVUPGUIFXBZ tø4UBJOMFTTTUFFMRVJDLSFMFBTFDBQUJWFIFYIFBEDPWFSCPMUT 4UBJOMFTTTUFFMTQSJOHTQSPWJEFDMFBSJOEJDBUJPODPWFSCPMUTBSFGVMMZ SFUSBDUFEGSPNCPEZ tø7FSTBUJMFJOUFSOBMPQFSBUJOHNFDIBOJTNTBMMPXGPSGJFMEBEKVTUNFOU UPBDDPNNPEBUFQPQVMBSNBOVGBDUVSFSTTUBSUFSTBOECSFBLFST tø4JNQMFTUSBJHIUGPSXBSEJOTUBMMBUJPOPGCSFBLFSBOETUBSUFSPOQSF drilled mounting plate within enclosure. Mounting plate also field SFNPWBCMF tø$JSDVJUCSFBLFSNPUPSDJSDVJUQSPUFDUPSFYUFSOBMPQFSBUJOHIBOEMFDBO CFQBEMPDLFEJOFJUIFSi0/wPSi0''wQPTJUJPOT tø/FPQSFOFDPWFSHBTLFUQFSNBOFOUMZBUUBDIFEUPUIFDPWFSTFBMTPVU moisture tø#PEJFTIBWFUPQBOECPUUPNESJMMFEBOEUBQQFEFOUSBODFTGPSQPXFS DPOEVJUTQMVTPOFBUUIFCPUUPNGPSDPOUSPMDPOEVJU3FNPWBCMF SFEVDFSTBSFTVQQMJFEBTTUBOEBSEUPBDDPNNPEBUFTNBMMFSTJ[F conduits. All conduit entrances are plugged. tø5BQPONPVOUJOHGFFU tø0QUJPOBM&.14DPOUSPMEFWJDFTNBZCFBEEFEUPFODMPTVSFDPWFS tø4UFFMCSBDLFUGPSMJGUJOHMBSHFSFODMPTVSFTEVSJOHJOTUBMMBUJPOTVQQMJFE as standard /BUJPOBM&MFDUSJDBM$PEFJTB3FHJTUFSFE5SBEFNBSLPGUIF/BUJPOBM'JSF1SPUFDUJPO Association. Interior components are readily accessible with ample end room for wiring Side operators leave cover free for control options Certifications and Compliances: tø/&$$&$ $MBTT*%JWJTJPO(SPVQT#$% $MBTT**%JWJTJPO(SPVQT&'( $MBTT**%JWJTJPO(SPVQT'( $MBTT*** tø6-4UBOEBSET6-o)B[BSEPVT$MBTTJGJFE -PDBUJPOT tø6-4VCKFDU)JHI"*$SBUJOH*OUFSSVQUJOH$BQBDJUZ 'PS(SPVQT$%POMZ Volt RMS Symm-Amperes 240 480 600 tø$4"4UBOEBSE$/P tø/&."&&."$3q9pp#$%&'( q&ODMPTVSFOPUTVJUBCMFGPS/&."PS9XJUIDPWFSNPVOUFEPQFSBUPST pp8JUI4PS4 Standard Materials: tø#PEZBOEDPWFSoDPQQFSGSFFBMVNJOVN tø0QFSBUJOHIBOEMFoDPQQFSGSFFBMVNJOVN tø0QFSBUJOHTIBGUTBOECVTIJOHToTUBJOMFTTTUFFM tø$PWFSCPMUTIJOHFTXBTIFSBOESFUSBDUJMFTQSJOHToTUBJOMFTTTUFFM tø*OUFSJPSQBSUToTIFFUTUFFMFMFDUSPHBMWBOJ[FE Electrical Rating Range: tø.PUPSTUBSUFSTo/&."&&."$TJ[FT tø$JSDVJUCSFBLFSTop BNQFSFGSBNFTJ[FT tø.PUPSDJSDVJUQSPUFDUPSToBNQFSFGSBNFTJ[FT p"NQFSF'SBNFNBYBNQFSFUSJQ www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton 1C EBM hinged cover motor control enclosures are used: tø'PSHFOFSBMNPUPSDPOUSPMBOEDJSDVJUQSPUFDUJPOoJOEPPSTBOE PVUEPPSToJOEBNQXFUEJSUZEVTUZIB[BSEPVTMPDBUJPOTXJUIPVU the need for a protective shelter tø*OBSFBTXIFSFGSFRVFOUXBTIEPXOTBSFOFDFTTBSZPSXIFSFIFBWZ rain or water spray is prevalent tø'PSBDSPTTUIFMJOFTUBSUJOHTUPQQJOHTQFFEDIBOHJOHBOESFWFSTJOH of polyphase AC induction motors tø5PQSPWJEFMJOFEJTDPOOFDUNFBOTBOETIPSUDJSDVJUQSPUFDUJPO tø5PQSPWJEFNPUPSPWFSMPBEBOEVOEFSWPMUBHFQSPUFDUJPO tø'PSTFSWJDFFOUSBODFGFFEFSPSCSBODIDJSDVJUQSPUFDUJPOGPSMJHIUJOH IFBUJOHBQQMJBODFBOENPUPSDJSDVJUT tø0OTXJUDISBDLTPSPUIFSBTTFNCMJFTXIFSFJUTEFTJSFEUIBUNPUPS DPOUSPMCFDFOUSBMMZMPDBUFE 1C EBMC Combination Line Starters and Enclosures Options: The following options are available from the factory by adding suffix to catalog number – suffixes are added alphanumerically. Catalog Number System Example EBMC1FB-c-WT30FDB36-W643-d cOptions in this position are additions to the enclosure itself and should be listed alphanumerically. 1C dOptions in this position are modifications to the starter and/or circuit breaker and should be listed alphanumerically. EBMC Series motor control enclosures with combination line starters. When specifying any one of the following options with EBM Motor Controls (J1, J3, PB23, RR2, RR3), it is necessary to order DSL Legend Plates for identification and marking of the device(s) being used. Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight Position Description in Cat. # Suffix t "NCJFOUDPNQFOTBUFEDJSDVJUCSFBLFSUSJQ setting ........................................................................ d AC t -FTTPWFSMPBESFMBZTMJHIUJOHDPOUBDUPS c CL t -FTTPWFSMPBESFMBZTNPUPSDPOUBDUPS c CM t $POUSPM$JSDVJU5SBOTGPSNFS7"GPS/&." EEMAC sizes 0–2, 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided) .............................................................. c FTPS100 t $POUSPM$JSDVJU5SBOTGPSNFS7"GPS/&." EEMAC size 3, 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided) .............................................................. c FTPS200 t $POUSPM$JSDVJU5SBOTGPSNFS7"GPS/&." EEMAC size 4, 5 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided) .............................................................. c FTPS300 t 1JMPUMJHIU7"$SFEKFXFMXCMBOL indicating plate .......................................................... c J1 t 1JMPUMJHIU7"$HSFFOKFXFMXCMBOL indicating plate .......................................................... c J3 t -&%QJMPUMJHIUTJOQMBDFPGTUBOEBSE incandescent lamps) .................................................. c LED t -FTTIFBUFSTJOTUBSUFSPWFSMPBESFMBZ d 0 t 4UBSU4UPQQVTICVUUPOTSFRVJSFTTQBDFT c PB23‡ t 0O0GGTFMFDUPSTXJUDI c RR2‡ t )BOE0GG"VUPTFMFDUPSTXJUDI c RR3‡ t 4QBDFIFBUFS7PMU8BUUT c R11 t 4QBDFIFBUFS7PMU8BUUT c R22 t 4QBDFIFBUFS7PMU8BUUT c R44 t "VUPNBUJDSFTFUPWFSMPBESFMBZ c S1 t *OTVMBUFEOFVUSBMXDPOOFDUPST c S146 t 4UEESBJO$MBTT*#$%$MBTT**&'($MBTT c *** S756‡ t 4UECSFBUIFSESBJO$MBTT*#$%$MBTT** &'($MBTT*** c S756V‡ t &YUFSOBMFQPYZGJOJTI c S752 t *OUFSOBMBOEFYUFSOBMFQPYZGJOJTI c S753 t "EEJUJPOBMDPOUSPMDPOUBDUT/0PS/$oGPSTJOHMF speed, non-reversing starters only (number limited by design of starter. Details on specific makes and TJ[FTPOSFRVFTU "VYJMJBSZDPOUBDUTPOTUBSUFS/0/$ d S781 "VYJMJBSZDPOUBDUTPOTUBSUFS/0/$ d S782 "VYJMJBSZDPOUBDUTPOTUBSUFS/0/$ d S783 t "VYJMJBSZTXJUDIPO$JSDVJU#SFBLFS"BOE# contacts ..................................................................... d S784 t "VYJMJBSZTXJUDIPO$JSDVJU#SFBLFS"BOE# contacts ..................................................................... d S785 t 1PJOUUFSNCMPDLo"NQ7 c S786 t (FOFSBMQVSQPTFDPOUSPMSFMBZQPMF/0DPOUBDUT SBUFE"!7DPJM7"$ 50 / 60 hertz ............................................................... c S787* *Use of this option with NEMA/EEMAC Size 0, or 1 starters necessitates using the larger “D” size enclosure. ‡Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. Breather and drain entries must be plugged for NEMA 4 rating. ††With S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 EBMC Combination Line Starters and Enclosures Explosionproof DustIgnitionproof Raintight Wet Locations Watertight 1C Options: t *GEFTJSFENBSLJOHTPOJOEJDBUJOHQMBUFTNBZCFBEEFEUPDBUBMPH number. Select from the list of standard markings below. t *OTFSUMFHFOEQMBUFT DBUBMPHOVNCFSJF%4- JNNFEJBUFMZ after optional device in the EBM catalog number. t *G&.1EFWJDFTBSFUPCFBEEFEJOUIFGJFME%4--FHFOE1MBUFT must be ordered separately, as they are not furnished with the EMP/EMPS devices. Example: EBMC1FB-c-WT30FDB36-W643-d Use the charts below to select the appropriate legend plate(s) for your application. Markings shown in bold printBSFFUDIFE all others are stamped. Single Function Legend Plates Two Function Legend Plates Background color for all legend plates is black with the following exceptions: Cat. # DSL16 DSL01 DSL02 DSL21 DSL23 DSL17 Marking Blank with 2 fields For-Rev Hand-Auto *O0VU Off-On Open-Close Cat. # DSL03 DSL30 DSL29 DSL35 DSL48 DSL32 Fast Forward Hand *O Jog Lower DSL46 DSL18 DSL15 DSL24 DSL10 DSL27 Raise-Lower Run-Jog Safe-Run Start-Stop Slow-Fast Up-Down DSL36 DSL28 DSL86 DSL37 DSL65 DSL33 On Off Open Out Power On Raise DSL07 DSL08 DSL20 DSL25 DSL14 DSL26 Three Function Legend Plates Reset Reverse Run Safe Slow Start DSL12 DSL19 DSL09 DSL85 DSL47 DSL05 Stop Test Trip Up DSL06 DSL13 DSL11 DSL22 Marking Auto-Off-Hand Blank with 3 fields Fast-Off-Slow For-Off-Rev Hand-Off-Auto Run-Off-Jog Cat. # DSL49 DSL04 DSL41 DSL40 DSL39 DSL38 Open-Off-Close Raise-Off-Lower Slow-Off-Fast Up-Off-Down 1-Off-2 DSL43 DSL87 DSL88 DSL44 DSL42 Marking Start Stop Emerg. Stop ‡Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton Plate Color (SFFO Red Red 1C Marking Automatic Blank Blank with single field Close Down Emerg. Stop 1C Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 EBMC Combination Line Starters and Enclosures Dimensions (In inches)† Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight Dimensions 1C In Inches: *1" Conduit entrance for control conductors (top & bottom). **Conduit entrance for power conductors (top & bottom). (All conduit entrances supplied with RE reducer and PLG plug.) J** Conduit Entry Trade Size D&T✪ w/RE Enclosure Enclosure Only Size Cat. # Symbol A B C D Size 0, 1 FVNR combination line starter§ EBMCFB B 25.75 24.75 26.90 6.00 13.03 14.78 12.13 2" Size 2 FVNR combination line starter EBMCFD D 28.25 27.25 29.40 6.00 Size 3 FVNR combination line starter EBMCFG■ G 38.13 36.50 39.28 6.00 EBMCFH H 37.50 36.50 38.65 6.00 E F G K N O P 1.5" 3.25 3.13 10.25 — — 22.00 13.03 14.67 12.13 3" 2.5" 3.25 3.13 10.25 — — 24.50 13.03 14.78 12.13 3" 14.65 16.65 13.54 3" 2.5" 2.5" 3.25 3.13 10.25 — 3.25 3.94 11.66 — — — 34.06 33.75 Size 4 FVNR combination line starter EBMCFK■ K 43.12 41.50 42.65 12.00 17.65 20.46 12.80 (2) 3" EBMCFL L 53.47 51.50 53.28 12.00 17.90 20.58 15.00 (2) 4" (2) 2.5" (2) 3.5" 3.25 3.00 10.78 — — 19.97 4.00 3.50 13.03 41.50 18.40 29.88 Size 5 FVNR combination line starter EBMCFM M 64.22 62.50 64.03 12.00 17.90 21.08 15.00 (2) 4" (2) 3.5" 4.00 3.50 13.03 41.50 18.40 34.46 †Dimensions are approximate, not for construction purposes. ‡Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. §Use EBMCFD enclosure when LVR1 or S787 options are ordered with Size 0 or 1 combination starters. ■For Cutler-Hammer W200 Advantage® starters. ✪Drilled & Tapped. 450 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business L M Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 EBMC Combination Line Starters and Enclosures Single-Speed Non-Reversing with Circuit Breakers 3-Pole 60 hertz, 600VAC Maximum Ordering Information: To order an enclosure complete with starter and breaker, insert the manufacturer’s symbols in the designated positions of the catalog number. Symbols are shown in the footnotes see page 452. Motor Starter Select the complete Cat. No. below and specify HP, voltage, frequency, RPM, type and full load ampere rating of motor – or specify ampere rating of heaters. 1C Instantaneous magnetic trip circuit breakers (magnetic circuit interrupters) can be supplied. Consult factory. For Combination starters with motor circuit protectors for single speed, non-reversing motors see page 453. Enclosures only can be ordered. Select from listings below. Circuit Breaker Explosionproof Dust-Ignitionproof Raintight Wet Locations Watertight Line Volts 120 120 120 NEMA Size 0 0 0 Amp Rating 30 30 30 Frame Volts 240 480 600 Frame Types TEB TED, EHD TED, FDB 3 3 3 240 240 240 0 0 0 20 20 20 240 480 600 TEB TED, EHD TED, FDB EBMCFB EBMCFB EBMCFB EBMC0FB ➀20➁32 ➂623 EBMC0FB ➀20➁34 ➂623 EBMC0FB ➀20➁36 ➂623 5 5 5 480 480 600 0 0 0 15 15 15 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFB EBMCFB EBMCFB EBMC0FB ➀15➁34 ➂643 EBMC0FB ➀15➁36 ➂643 EBMC0FB ➀15➁36 ➂663 5 5 5 240 240 240 1 1 1 30 30 30 240 480 600 TEB TED, EHD TED, FDB EBMCFB EBMCFB EBMCFB EBMC1FB ➀30➁32 ➂623 EBMC1FB ➀30➁34 ➂623 EBMC1FB ➀30➁36 ➂623 71/ 2 71/ 2 71/ 2 240 240 240 1 1 1 50 50 50 240 480 600 TEB TED, EHD TED, FDB EBMCFB EBMCFB EBMCFB EBMC1FB ➀50➁32 ➂623 EBMC1FB ➀50➁34 ➂623 EBMC1FB ➀50➁36 ➂623 10 10 10 480 480 600 1 1 1 30 30 30 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFB EBMCFB EBMCFB EBMC1FB ➀30➁34 ➂643 EBMC1FB ➀30➁36 ➂643 EBMC1FB ➀30➁36 ➂663 10 10 10 240 240 240 2 2 2 50 50 50 240 480 600 TEB TED, EHD TED, FDB EBMCFD EBMCFD EBMCFD EBMC2FD ➀50➁32 ➂623 EBMC2FD ➀50➁34 ➂623 EBMC2FD ➀50➁36 ➂623 15 15 15 240 240 240 2 2 2 70 70 70 240 480 600 TEB TED, EHD TED, FDB EBMCFD EBMCFD EBMCFD EBMC2FD ➀70➁32 ➂623 EBMC2FD ➀70➁34 ➂623 EBMC2FD ➀70➁36 ➂623 15 15 15 480 480 600 2 2 2 40 40 40 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFD EBMCFD EBMCFD EBMC2FD ➀40➁34 ➂643 EBMC2FD ➀40➁36 ➂643 EBMC2FD ➀40➁36 ➂663 20 20 20 480 480 600 2 2 2 50 50 50 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFD EBMCFD EBMCFD EBMC2FD ➀50➁34 ➂643 EBMC2FD ➀50➁36 ➂643 EBMC2FD ➀50➁36 ➂663 25 25 25 480 480 600 2 2 2 70 70 70 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFD EBMCFD EBMCFD EBMC2FD ➀70➁34 ➂643 EBMC2FD ➀70➁36 ➂643 EBMC2FD ➀70➁36 ➂663 20 25 30 240 240 240 3 3 3 90 100 125 240 240 480 TEB TEB TED EBMCFH EBMCFH EBMCFH EBMC3FH ➀90➁32 ➂623 EBMC3FH ➀100➁32 ➂623 EBMC3FH ➀125➁34 ➂623 30 30 30 ➀➁➂ 480 480 600 3 3 3 70 70 70 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFH EBMCFH EBMCFH EBMC3FH ➀70➁34 ➂643 EBMC3FH ➀70➁36 ➂643 EBMC3FH ➀70➁36 ➂663 With Breaker & Starter Cat. # § EBMC0FB ➀30➁32 ➂613 EBMC0FB ➀30➁34 ➂613 EBMC0FB ➀30➁36 ➂613 See page 452 for configurable options. The standard coil voltage is equal to the line voltage. To include a 120V coil, insert a “1” between the last two characters in the catalog number. The 120V coil is required with the FTPS suffix. Example: EBMC1FB-➀30➁36-➂643 becomes EBMC1FB-➀30➁36-➂6413 ‡Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. §Starters are furnished with 3 heaters, when heater ratings are fully specified. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2014 Eaton’s Crouse-Hinds Business 1C Max. HP Polyphase 2 2 2 Enclosure Without Breaker & Starter Cat. # EBMCFB EBMCFB EBMCFB 1C Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 EBMC Combination Line Starters and Enclosures Single-Speed Non-Reversing 3-pole 60 Hertz, 600VAC Maximum Max. HP Polyphase Line Volts NEMA Size Amp Rating Frame Volts Frame Types Enclosure Without Breaker & Starter Cat. # 40 40 40 480 480 600 3 3 3 90 90 90 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFH EBMCFH EBMCFH EBMC3FH ➀90➁34 ➂643 EBMC3FH ➀90➁36 ➂643 EBMC3FH ➀90➁36 ➂663 50 50 50 480 480 600 3 3 3 100 100 100 480 600 600 TED, EHD TED, FDB TED, FDB EBMCFH EBMCFH EBMCFH EBMC3FH ➀100➁34 ➂643 EBMC3FH ➀100➁36 ➂643 EBMC3FH ➀100➁36 ➂663 40 50 60 60 75 75 100 100 240 240 480 600 480 600 480 600 4 4 4 4 4 4 4 4 175 200 125 100 150 125 200 150 600 600 600 600 600 600 600 600 JD, JD, JD, JD, JD, JD, JD, JD, EBMCFL EBMCFL EBMCFL EBMCFL EBMCFL EBMCFL EBMCFL EBMCFL EBMC4FL EBMC4FL EBMC4FL EBMC4FL EBMC4FL EBMC4FL EBMC4FL EBMC4FL 125 150 480 480 5 5 300 400 600 600 KD, KDB KD, KDB EBMCFM EBMCFM EBMC5FM WT300➁36 ➂643 EBMC5FM WT400➁36 ➂643 Motor Starter 1C Explosionproof Dust-ignitionproof Raintight Wet Locations Watertight Circuit Breaker Motor Starter JDB JDB JDB JDB JDB JDB JDB JDB With Breaker & Starter Cat. # § WT175➁36 ➂623 WT200➁36 ➂623 ➀125➁36 ➂643 ➀100➁36 ➂663 ➀150➁36 ➂643 ➀125➁36 ➂663 WT200➁36 ➂643 ➀150➁36 ➂663 Fusible Disconnect Switch Max. HP Polyphase Max. Line Volts NEMA Size Amp Rating Max. Volts Switch Type With Disconnect Switch & Starter Cat. # 5 10 25 30 600 600 600 600 0 1 2 3 30 30 60 100 600 600 600 600 DS161R DS161R DS262R DS363R EBMC0FD EBMC1FD EBMC2FD EBMC3FH ➀Circuit Breakers: Manufacturer Cutler-Hammer General Electric WFD30J36 W643 WFD30J36 W643 WFD60J36 W643 WFD100J36 W643 NEMA Size Without Switch & Starter Cat. # Symbol 0 1 2 3 WT TT EBMCFD EBMCFD EBMCFD EBMCFH ➁Select Circuit Breaker Frame Type based on Frame Size, Voltage, and Manufacturer desired: 100 Amp. Frame and 150 Amp. Frame 250 Amp. 400 Amp. 600 Amp. 240V 480V 600V Frame Frame Frame Manufacturer AC AC AC 600VAC 600VAC 600VAC Cutler-Hammer — EHD FDB HFD♣ General Electric TEB TED TED JD✡ JDB✜ HJD♣ KD✡ KDB✜ HKD★ LD HLD★ ✡–Interchangeable Trip Unit ✜–Non-Interchangeable Trip Unit ♣–Cutler-Hammer HFD and HJD are rated at 65 kAIC at 480V and 25 kAIC at 600V. ★–Cutler-Hammer HKD and HLD are rated at 65 kAIC at 480V and 35 kAIC at 600V. ➂Motor Starters: Manufacturer Allen Bradley Square D General Electric Cutler-Hammer Symbol AB D G W ‡Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. §Starters are furnished with 3 heaters, when heater ratings are fully specified. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton FD FD FD FD 800 Amp. Frame 600VAC MD EBMC Combination Line Starters Single-Speed Non-Reversing with Motor Circuit Protectors 3-pole 60 Hertz, 600VAC Maximum Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 Explosionproof Dust-ignitionproof Raintight Wet Locations Watertight 1C Ordering Information: Select the complete Catalog No. below and specify HP, voltage, frequency, RPM, type and full load ampere rating of motors or specify ampere rating of heaters. Motor Starter MCP Amp Rating Enclosure without Starter & MCP Cat. # Enclosure with Starter & MCP Cat. # § 240 480 600 480 600 0 0 0 0 0 15 7 7 15 15 EBMCFB EBMCFB EBMCFB EBMCFB EBMCFB EBMC0FB EBMC0FB EBMC0FB EBMC0FB EBMC0FB WP15AHMCP36 ➂623 WP7AHMCP36 ➂643 WP7AHMCP36 ➂663 WP15AHMCP36 ➂643 WP15AHMCP36 ➂663 71/2 71/2 10 10 240 480 480 600 1 1 1 1 30 15 30 15 EBMCFB EBMCFB EBMCFB EBMCFB EBMC1FB EBMC1FB EBMC1FB EBMC1FB WP30AHMCP36 WP15AHMCP36 WP30AHMCP36 WP15AHMCP36 10 15 15 20 25 25 240 240 480 600 480 600 2 2 2 2 2 2 50 100 30 30 50 50 EBMCFD EBMCFD EBMCFD EBMCFD EBMCFD EBMCFD EBMC2FD EBMC2FD EBMC2FD EBMC2FD EBMC2FD EBMC2FD WP50BHMCP36 ➂623 WP100BHMCP36 ➂623 WP30AHMCP36 ➂643 WP30AHMCP36 ➂663 WP50BHMCP36 ➂643 WP50BHMCP36 ➂663 30 30 50 50 240 600 480 600 3 3 3 3 100 50 100 100 EBMCFH EBMCFH EBMCFH EBMCFH EBMC3FH EBMC3FH EBMC3FH EBMC3FH WP100BHMCP36 ➂623 WP50BHMCP36 ➂663 WP100BHMCP36 ➂643 WP100BHMCP36 ➂663 50 100 100 240 480 600 4 4 4 250 250 250 EBMCFL EBMCFL EBMCFL EBMC4FL WP250JHMCP36 ➂623 EBMC4FL WP250JHMCP36 ➂643 EBMC4FL WP250JHMCP36 ➂663 60 100 125 150 200 200 240 240 480 600 480 600 5 5 5 5 5 5 250 400 250 250 400 400 EBMCFM EBMCFM EBMCFM EBMCFM EBMCFM EBMCFM EBMC5FM EBMC5FM EBMC5FM EBMC5FM EBMC5FM EBMC5FM 3 3 3 5 5 Motor Circuit Protectors: Manufacturer Cutler-Hammer Symbol WP Motor Circuit Protector Frame Type based on Frame Size and Manufacturer desired: 150 Amp. 250 Amp. 400 Amp. Frame Frame Frame Cutler-Hammer ➂Motor Starters: Manufacturer Allen Bradley Square D General Electric Cutler-Hammer HMCP (F-Frame) HMCP (J-Frame) HMCP (K-Frame) MCP Amp Rating Cutler-Hammer (WP) 7 15 30 50 100 250 400 WP250JHMCP36 ➂623 WP400GHMCP36 ➂623 WP250JHMCP36 ➂643 WP250JHMCP36 ➂663 WP400GHMCP36 ➂643 WP400GHMCP36 ➂663 Symbol Trip Range A A A B B J G 21 to 70 45 to 150 90 to 300 150 to 500 300 to 1000 1250 to 2500 1250 to 2500 Consult factory for other trip ranges available. Symbol AB D G W ‡ Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. §Starters are furnished with three heaters when heater ratings are fully specified. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 ➂623 ➂643 ➂643 ➂663 Copyright© 2016 Eaton 1C Volts NEMA Size Max. HP Polyphase