Fiberglass - 6” Straight Section 15⁄8" (41) Rung Spacing NEMA 5" fill 6" (152) For side rail data, see charts on pages APP-8 Overall Width (Width + 7/8”) One pair of splice plates with SS6 (316 Stainless Steel) hardware included 1" (25) Series 36 Fiberglass Straight Section Part Numbering Prefix Example: 36 F 09 - 24 - 120 Series 36 Material Type F = Polyester FV = Vinyl Ester FA = Zero Halogen/ Dis-Stat Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing Width Fiberglass FA = Zero Halogen/ Dis-Stat is 06 09 12 18 24 30 36 = = = = = = = 6" 9" 12" 18" 24" 30" 36" See page FCT-52 for additional rung options. B-Line Series Side Rail Dimensions 1.625 36F 36FV NEMA 5” fill ¨ ¡ Length 120 = 10 ft. 240 = 20 ft. ¨Primary Length. Length. ¡Secondary See page CTS-23 for explanation of lengths. NEMA & CSA Classifications Span ft Load lbs/ft Deflection Multiplier Span meters Load kg/m Deflection Multiplier NEMA: 20B 12 246 0.006 3.7 367 0.104 CSA: E-6m 14 181 0.011 4.3 269 0.193 16 139 0.019 4.9 206 0.330 18 109 0.031 5.5 163 0.528 20 89 0.047 6.1 132 0.811 NEMA & CSA Classifications Span ft Load lbs/ft Span meters Load kg/m NEMA: 20B 12 208 3.7 309 CSA: E-6m 14 153 4.3 227 16 117 4.9 174 6.00 36 1.00 B-Line Series Side Rail Dimensions 1.625 36FA NEMA 5” fill 6.00 18 93 5.5 138 20 75 6.1 111 1.00 Values are based on simple beam tests per NEMA VFG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. FCT-23 Cable Tray Systems Fiberglass 15⁄8" (41) NEMA 5" fill 6” Straight Section Rung Spacing For side rail data, see charts on pages APP-8 6" (152) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Overall Width (Width + 1”) 1" (25) Series 46 Fiberglass Straight Section Part Numbering Prefix Example: 46 F 09 - 24 - 120 Series 46 Material Type F = Polyester FV = Vinyl Ester FA = Zero Halogen/ Dis-Stat Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing Width = = = = = = = 6" 9" 12" 18" 24" 30" 36" See page FCT-52 for additional rung options. B-Line Series Side Rail Dimensions 1.625 46F 46FV NEMA 5” fill NEMA & CSA Classifications 1.625 46FA NEMA 5” fill Deflection Multiplier Span meters ¨Primary Load kg/m Deflection Multiplier 12 393 0.005 3.7 584 0.079 288 0.009 4.3 429 0.145 16 221 0.015 4.9 329 0.246 18 174 0.023 5.5 260 0.396 20 141 0.035 6.1 210 0.605 Span ft Load lbs/ft Span meters Load kg/m NEMA: 20C+ 12 278 3.7 413 CSA: E-6m 14 204 4.3 303 16 156 4.9 232 18 123 5.5 183 20 100 6.1 149 6.00 1.00 Length. Length. See page CTS-23 for explanation of lengths. 14 NEMA & CSA Classifications 46 ¡Secondary CSA: E-6m 6.00 Side Rail Dimensions Load lbs/ft ¡ Length 120 = 10 ft. 240 = 20 ft. NEMA: 20C+ 1.00 B-Line Series Span ft ¨ Values are based on simple beam tests per NEMA VFG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. Cable Tray Systems FCT-24 Fiberglass FA = Zero Halogen/ Dis-Stat is 06 09 12 18 24 30 36 Fiberglass - 6” Straight Section Rung Spacing 15⁄8" (41) For side rail data, see charts on pages APP-8 NEMA 5" fill 6" (152) One pair of splice plates with SS6 (316 Stainless Steel) hardware included Overall Width (Width + 1”) 1" (25) Series H46 Fiberglass Straight Section Part Numbering Prefix Example: H46 F 09 - 24 - 120 Series Fiberglass H46 Material Type Width F = Polyester FV = Vinyl Ester FA = Zero Halogen/ Dis-Stat Ladder 06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing FA = Zero Halogen/ Dis-Stat is 06 09 12 18 24 30 36 = = = = = = = 6" 9" 12" 18" 24" 30" 36" See page FCT-52 for additional rung options. B-Line Series Side Rail Dimensions 1.625 H46F H46FV NEMA 5” fill NEMA & CSA Classifications Span ft Load lbs/ft Deflection Multiplier Span meters Load kg/m Length ¨ 120 = 10 ft. 240 = 20 ft. ¡ ¨Primary Length. Length. ¡Secondary See page CTS-23 for explanation of lengths. Deflection Multiplier NEMA: 20C+ 12 424 0.005 3.7 631 0.079 CSA: E-6m 14 312 0.009 4.3 464 0.144 16 239 0.015 4.9 355 0.248 18 188 0.023 5.5 280 0.396 20 153 0.035 6.1 227 0.608 Span ft Load lbs/ft Span meters Load kg/m 455 6.00 H46 1.00 B-Line Series Side Rail Dimensions 1.625 H46FA NEMA 5” fill NEMA & CSA Classifications NEMA: 20C+ 12 306 3.7 CSA: E-6m 14 224 4.3 333 16 172 4.9 245 6.00 18 136 5.5 202 20 110 6.1 163 1.00 Values are based on simple beam tests per NEMA VFG-1 on 36" wide cable tray rungs spaced on 12" centers. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable being installed. When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Green = Fastest shipped items Black = Normal lead-time items Red = Normally long lead-time items Dimensions shown in parentheses are in millimeters, unless otherwise specified. FCT-25 Cable Tray Systems