For ConTech Lighting Low Voltage Mono-Point Canopies: LA1816 and LA1816 277V 1. Attach the mounting bracket to the junction box with the included screws. Utilize the long cylindrical channels on the bracket. 2. Connect the power supply wires to the wires inside the mono-point canopy with the included wire nuts. 3. Run the included Philips head screws through the (2) holes in the canopy; align the screws with the furthest circular holes on the mounting bracket and tighten the screws. 4. To attach the fixture to the canopy, pull the connector out from the canopy and attach it to the connector on the fixture. 5. Align the fixture with the hole in the canopy, twist the fixture clockwise until the fixture turns past the locking tab. Alternative Fixture Installation Using Extension Stems 1. Pull the connector out from the canopy and attach it to the connector on the stem. 2. Align the stem with the hole in the canopy and twist the stem clockwise until it turns past the locking tab. 3. Then pull the connector out from the stem base and attach it to the connector on the fixture. 4. Align fixture with the hole in the stem base and twist the fixture clockwise until it turns past the locking tab. CAUTION: Stem extension should not exceed 18" in length. IMPORTANT SAFETY INSTRUCTIONS: • Read all the instructions before installation. Save instructions for later use. • Turn off the power at fuse or circuit breaker box before installation or any maintenance work. • Wear rubber soled shoes and work on a sturdy wooden or non-conductive ladder. • Product must be mounted in locations and at heights in compliance with National Electrical Code and local building codes. For indoor use only. • Do not exceed the nominal supply voltage or amperage ratings. • Installing contrary to instructions may cause unsafe conditions. • Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation. • To avoid hazards to children, account for all parts and properly dispose of all packing materials. • Call the Technical Support department at ConTech Lighting with any installation questions. All specifications subject to change without notice. 1-847-559-5500 www.contechlighting.com This document can be recycled. LA1816 INST