HALO INSTALLATION INSTRUCTIONS FOR H2600/H2601 CHORUS ARCHITECTURAL PENDANT SERIES WARNING Fig. 1 Safety Information Read carefully for your protection and save all instructions. • Disconnect power before installing light fixture • Wear rubber-soled shoes and work on a sturdy wooden ladder. • This fixture must be installed according to National Electric Code and local building codes. • To avoid a hazard to children, account for all parts and destroy all packing materials. • If you are unsure about wiring, consult a qualified electrician before installing. • WARNING: To reduce the risk of fire and electrical shock, use only fixtures and fittings intended for use with Halo systems OPERATION: The H2600 and H2601 architectural pendant is available in incandescent, Compact Fluorescent and Ceramic Metal Halide with input voltage of 120VAC 50/60HZ for incandescent and 120VAC to 277VAC 50/60 HZ for fluorescent and HID. Be sure to use the correct lamp type and wattage for your fixture. In the event of a shutdown the Ceramic Metal Halide lamp will restrike in approximately 5 minutes. NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR AN R.F. LIGHTING DEVICE PURSUANT TO PART 18C OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WITH ELECTRONIC DEVICES SUCH AS : RADIOS, TELEVISIONS, WIRELESS TELEPHONES OR REMOTE CONTROLS. IF INTERFERENCE OCCURS IT MAY BE POSSIBLE TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES; • REORIENT OR RELOCATE ANTENNA OF THE RECEIVING DEVICE • INCREASE THE SEPARATION BETWEEN THIS EQUIPMENT AND THE DEVICE. • CONNECT THIS EQUIPMENT OR THE DEVICE INTO A DIFFERENT OUTLET OR CIRCUIT THIS EQUIPMENT SHOULD NOT BE USED; • CLOSER THAN THREE (3) FEET FROM ANY SENSITIVE ELECTRONIC EQUIPMENT • NEAR MARITIME SAFETY, NAVIGATION, OR COMMUNICATIONS EQUIPMENT Plastic Nuts Fig. 2 Reflector Ring for Use with Acrylic Reflector Fig. 3 Reflector Ring for Use with Acrylic Reflector Reflector Reflector Mounting Plate Plastic Nuts Fig. 4 Octagon Box Service: Canopy Contact point of purchase for service or to return defective product. INSTALLATION Ground Wires The H2600/H2601 can be mounted directly to a 4" octagon junction box, a 4" x 4" square junction box with a plaster reducing ring, or to a conduit feed. Prior to installation, assemble the fixture according to the following instructions: STEP 1. STEP 2. STEP 3. Remove the plastic nuts from the base (Fig. 1). For assembly of the H2600 Prismatic Pendants place the reflector ring over the base bottom (Fig. 2) (No reflector ring is used in combination with the H2601 Aluminum reflector pendants). Position the reflector over the reflector ring. Place the reflector mounting plate inside the reflector, fitting it over the screws in the base, and mount the reflector mounting plate and reflector to the base with the two plastic nuts which were removed in Step 1 (Fig. 3). Fig. 5 4" Square Junction Box Plaster Reducing Ring Mounting Screws Canopy Ground Wires Customer First Center • 1121 Highway 74 South •Peachtree City, GA 30269 • 770.486.4800 702863 Fig. 6 Installation with 4" Octagon Junction Box STEP 1. Disassemble the canopy and the canopy cover STEP 2. Feed the wire leads from junction box through the center hole of the canopy (Fig. 4). Mount the canopy to the junction box. Do not tighten the screws. Rotate the canopy to the desired position before tightening the screws. Connect the ground wire to the ground lead on the canopy (Fig. 4). STEP 3. Proceed to Step 1 of Fixture Mounting Canopy Remove Knockout Mounting Screws Ground Wires Installation with 4" Square Junction Box Note: Make sure a plaster reducing ring with 2 3/4" trade size mounting centers has been installed prior to mounting fixture. STEP 1. Disassemble the canopy and the canopy cover STEP 2. Feed the wire leads from junction box through the plaster reducing ring and the center hole of the canopy. Mount the canopy to the plaster reducing ring. Do not tighten the screws (Fig. 5). Rotate the canopy to the desired position before tightening the screws. With a wire nut, Connect the ground wire to the ground lead on the canopy (Fig. 5). STEP 3. Conduit Feed Fig. 7 Canopy Cable Supply Wires (white to White, Black to Black Canopy Cover Strain Relief Proceed to Step 1 of Fixture Mounting Power Cord Installation without a Junction Box onto a Conduit Feed STEP 1. Disassemble the canopy and the canopy cover STEP 2. Using a screwdriver, pry the knockouts in the canopy to break the tabs. Feed the conduit directly to the canopy knockouts (Fig. 6). Mount the canopy to the ceiling or ceiling grid and tighten the screws. Using a wire nut, connect the ground wire to the ground lead on the canopy. STEP 3. Proceed to Step 1 of Fixture Mounting Fig. 8 Cable Use Level to Make sure Base is Horizontal Cable Support Fixture Mounting STEP 1. Feed the cable provided through the ends of the canopy (Fig. 7). Feed the power cord through the strain relief in the canopy cover (Fig. 7). Do not tighten the strain relief yet. Cut the power cord to the appropriate length and strip the wires 3/8". Connect the supply voltage lead to the fixture voltage lead with a wire nut. Connect neutral supply lead to fixture lead marked COM (Fig. 7). STEP 2. Cut cable to desired length and insert the ends of the cable through the cable supports on the base. Before tightening the cable support screws, adjust the horizontal position of the fixture with a level (Fig. 8). Use an Allen key to tighten the cable support screws. STEP 3. Plug the input lead connector into the base connector (Fig. 9). STEP 4. Position the canopy cover under the canopy. Secure the canopy cover to the canopy with the screws previously removed in Step 1 of the installation options (Fig. 10). STEP 5. Pull the power cord upwards and tighten the strain relief screw. Position the cables through the slots in the canopy cover (Fig. 11). Fig. 9 Input Lead Connector Fig. 10 Canopy Cover Canopy Cover Mounting Screws Relamping Instructions WARNING: Before working on fixture, be sure to turn off AC power at the breaker panel. STEP 1. Fig. 11 Canopy Cover If using a glass diffuser disassemble the fixture as noted in the Glass Diffuser Kit instructions and remove the glass diffuser. STEP 2. Remove lamp. STEP 3. Replace lamp STEP 4. If using a glass diffuser, re-attach the glass diffuser according to the Glass Strain Relief Diffuser Kit instructions and remount the fixture. Customer First Center • 1121 Highway 74 South •Peachtree City, GA 30269 • 770.486.4800 702863