WARNING
Fig. 1
Safety Information
Read carefully for your protection and save all instructions.
•
Disconnect power before installing light fixture
•
Wear rubber-soled shoes and work on a sturdy wooden ladder.
•
This fixture must be installed according to National Electric Code and local building
codes.
•
To avoid a hazard to children, account for all parts and destroy all packing materials.
•
If you are unsure about wiring, consult a qualified electrician before installing.
•
WARNING: To reduce the risk of fire and electrical shock, use only fixtures and
fittings intended for use with Halo systems
OPERATION: The H2600 and H2601 architectural pendant is available in incandescent,
Compact Fluorescent and Ceramic Metal Halide with input voltage of 120VAC 50/60HZ for
incandescent and 120VAC to 277VAC 50/60 HZ for fluorescent and HID. Be sure to use the
correct lamp type and wattage for your fixture. In the event of a shutdown the Ceramic
Metal Halide lamp will restrike in approximately 5 minutes.
NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE
LIMITS FOR AN R.F. LIGHTING DEVICE PURSUANT TO PART 18C OF THE FCC RULES.
THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
HARMFUL INTERFERENCE WITH ELECTRONIC DEVICES SUCH AS : RADIOS,
TELEVISIONS, WIRELESS TELEPHONES OR REMOTE CONTROLS. IF INTERFERENCE
OCCURS IT MAY BE POSSIBLE TO CORRECT THE INTERFERENCE BY ONE OR MORE OF
THE FOLLOWING MEASURES;
• REORIENT OR RELOCATE ANTENNA OF THE RECEIVING DEVICE
• INCREASE THE SEPARATION BETWEEN THIS EQUIPMENT AND THE DEVICE.
• CONNECT THIS EQUIPMENT OR THE DEVICE INTO A DIFFERENT OUTLET OR
CIRCUIT
THIS EQUIPMENT SHOULD NOT BE USED;
• CLOSER THAN THREE (3) FEET FROM ANY SENSITIVE ELECTRONIC EQUIPMENT
• NEAR MARITIME SAFETY, NAVIGATION, OR COMMUNICATIONS EQUIPMENT
Plastic Nuts
Fig. 2
Reflector Ring
for Use with
Acrylic
Reflector
Fig. 3
Reflector Ring
for Use with
Acrylic
Reflector
Reflector
Reflector
Mounting Plate
Plastic Nuts
Fig. 4
Octagon Box
Service:
Canopy
Contact point of purchase for service or to return defective product.
INSTALLATION
Ground Wires
The H2600/H2601 can be mounted directly to a 4" octagon junction box, a 4" x 4" square
junction box with a plaster reducing ring, or to a conduit feed.
Prior to installation, assemble the fixture according to the following instructions:
STEP 1.
STEP 2.
STEP 3.
Remove the plastic nuts from the base (Fig. 1).
For assembly of the H2600 Prismatic Pendants place the reflector ring over the
base bottom (Fig. 2) (No reflector ring is used in combination with the H2601
Aluminum reflector pendants).
Position the reflector over the reflector ring. Place the reflector mounting plate
inside the reflector, fitting it over the screws in the base, and mount the
reflector mounting plate and reflector to the base with the two plastic nuts
which were removed in Step 1 (Fig. 3).
Fig. 5
4" Square
Junction Box
Plaster
Reducing Ring
Mounting
Screws
Canopy
Ground Wires
Customer First Center • 1121 Highway 74 South •Peachtree City, GA 30269 • 770.486.4800
702863
Fig. 6
Installation with 4" Octagon Junction Box
STEP 1.
Disassemble the canopy and the canopy cover
STEP 2.
Feed the wire leads from junction box through the center hole of the canopy
(Fig. 4). Mount the canopy to the junction box. Do not tighten the screws.
Rotate the canopy to the desired position before tightening the screws.
Connect the ground wire to the ground lead on the canopy (Fig. 4).
STEP 3.
Proceed to Step 1 of Fixture Mounting
Canopy
Remove
Knockout
Mounting
Screws
Ground Wires
Installation with 4" Square Junction Box
Note:
Make sure a plaster reducing ring with 2 3/4" trade size mounting centers has
been installed prior to mounting fixture.
STEP 1.
Disassemble the canopy and the canopy cover
STEP 2.
Feed the wire leads from junction box through the plaster reducing ring and
the center hole of the canopy. Mount the canopy to the plaster reducing ring.
Do not tighten the screws (Fig. 5). Rotate the canopy to the desired position
before tightening the screws. With a wire nut, Connect the ground wire to the
ground lead on the canopy (Fig. 5).
STEP 3.
Conduit Feed
Fig. 7
Canopy
Cable
Supply Wires
(white to White,
Black to Black
Canopy Cover
Strain Relief
Proceed to Step 1 of Fixture Mounting
Power Cord
Installation without a Junction Box onto a Conduit Feed
STEP 1.
Disassemble the canopy and the canopy cover
STEP 2.
Using a screwdriver, pry the knockouts in the canopy to break the tabs. Feed
the conduit directly to the canopy knockouts (Fig. 6). Mount the canopy to the
ceiling or ceiling grid and tighten the screws. Using a wire nut, connect the
ground wire to the ground lead on the canopy.
STEP 3.
Proceed to Step 1 of Fixture Mounting
Fig. 8
Cable
Use Level to
Make sure
Base is
Horizontal
Cable Support
Fixture Mounting
STEP 1.
Feed the cable provided through the ends of the canopy (Fig. 7). Feed the
power cord through the strain relief in the canopy cover (Fig. 7). Do not
tighten the strain relief yet. Cut the power cord to the appropriate length and
strip the wires 3/8". Connect the supply voltage lead to the fixture voltage lead
with a wire nut. Connect neutral supply lead to fixture lead marked COM
(Fig. 7).
STEP 2.
Cut cable to desired length and insert the ends of the cable through the cable
supports on the base. Before tightening the cable support screws, adjust the
horizontal position of the fixture with a level (Fig. 8). Use an Allen key to
tighten the cable support screws.
STEP 3.
Plug the input lead connector into the base connector (Fig. 9).
STEP 4.
Position the canopy cover under the canopy. Secure the canopy cover to the
canopy with the screws previously removed in Step 1 of the installation
options (Fig. 10).
STEP 5.
Pull the power cord upwards and tighten the strain relief screw. Position the
cables through the slots in the canopy cover (Fig. 11).
Fig. 9
Input Lead
Connector
Fig. 10
Canopy Cover
Canopy Cover
Mounting
Screws
Relamping Instructions
WARNING: Before working on fixture, be sure to turn off AC power at the breaker panel.
STEP 1.
Fig. 11
Canopy Cover
If using a glass diffuser disassemble the fixture as noted in the Glass Diffuser
Kit instructions and remove the glass diffuser.
STEP 2.
Remove lamp.
STEP 3.
Replace lamp
STEP 4.
If using a glass diffuser, re-attach the glass diffuser according to the Glass
Strain Relief
Diffuser Kit instructions and remount the fixture.