FINAL REPORT CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION FROM FINCH AVENUE NORTHERLY TO BANTRY AVENUE YORK REGION RAPID TRANSIT CORPORATION PREPARED FOR: JANUARY 2009 PREPARED BY: Environmental 2655 North Sheridan Way, St. 280 Mississauga, ON L5K 2P8 Ph: 905-823-4988 • Fx: 905-823-2669 Email: ecoplans@ecoplans.com PROJECT NO. 10-6959 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 TABLE OF CONTENTS EXECUTIVE SUMMARY ........................................................................................................................III 1.0 1.1 1.2 2.0 INTRODUCTION ........................................................................................................................... 1 PROJECT OBJECTIVE ...................................................................................................................... 1 PROPOSED WORKS ......................................................................................................................... 1 PHYSICAL SETTING.................................................................................................................... 3 2.1 LOCATION AND SIZE ...................................................................................................................... 3 2.2 CURRENT LAND USE...................................................................................................................... 3 2.3 TOPOGRAPHY AND DRAINAGE ....................................................................................................... 3 2.4 PHYSIOGRAPHY ............................................................................................................................. 3 2.5 GEOLOGY ...................................................................................................................................... 3 2.5.1 Overburden Geology ................................................................................................................ 3 2.5.2 Bedrock Geology ...................................................................................................................... 4 2.6 HYDROGEOLOGY ........................................................................................................................... 4 2.6.1 Overburden Aquifer.................................................................................................................. 4 2.6.2 Bedrock Aquifer........................................................................................................................ 4 3.0 RECORDS REVIEW...................................................................................................................... 5 3.1 EXISTING REPORTS ........................................................................................................................ 5 3.2 AERIAL PHOTOGRAPHS .................................................................................................................. 5 3.3 ECOLOG ERIS ENVIRONMENTAL AND HISTORICAL INFORMATION................................................ 6 3.3.1 Certificates of Approval (1988-2002)....................................................................................... 6 3.3.2 Commercial Fuel Oil Tanks (1948-2008)................................................................................. 7 3.3.3 Fuel Storage Tanks (current to 2007)....................................................................................... 7 3.3.4 Private and Retail Fuel Storage Tanks (1989-1996) ................................................................ 7 3.3.5 Retail Fuel Storage Tanks (2000-2008).................................................................................... 7 3.3.6 Ontario Spills (1988-2002)....................................................................................................... 7 3.3.7 Waste Disposal Sites – MOE C of A Inventory (1970-2002) .................................................... 7 3.3.8 Andersons Waste Disposal Sites (1930-2004) .......................................................................... 8 3.3.9 Automobile Wrecking and Supplies (2001-2007) ..................................................................... 8 3.3.10 Ontario Regulation 347 Waste Generators Summary (1986-2008) ..................................... 8 3.3.11 Record of Site Condition (1997-2008) ................................................................................. 8 3.3.12 Pesticide Register (1988-2007) ............................................................................................ 9 3.3.13 Ontario Inventory of PCB Storage Sites (1987-2004).......................................................... 9 3.3.14 National PCB Inventory (1988-2004) .................................................................................. 9 3.3.15 National Pollutant Release Inventory (1993-2006).............................................................. 9 3.3.16 Scott’s Manufacturing Directory (1992-2008)................................................................... 10 3.3.17 Federal Contaminated Sites and Solid Waste Landfills (2000-2007) ................................ 10 4.0 STUDY AREA INSPECTION ..................................................................................................... 11 5.0 KEY FINDINGS OF STUDY....................................................................................................... 12 5.1 POTENTIAL SOURCES OF CONTAMINATION .................................................................................. 12 5.1.1 Commercial and Industrial Land Use .................................................................................... 12 5.1.2 Historical Agricultural Operations ........................................................................................ 12 5.2 CONTAMINANT MOBILITY ........................................................................................................... 13 5.2.1 Significance of Mobility within the Study Area....................................................................... 13 6.0 AREAS OF POTENTIAL ENVIRONMENTAL CONCERN .................................................. 14 Project No.: 10-6959 Page i Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 7.0 RECOMMENDATIONS .............................................................................................................. 15 8.0 CLOSURE...................................................................................................................................... 16 9.0 QUALIFICATIONS OF THE ENVIRONMENTAL CONSULTANT .................................... 17 10.0 REFERENCES .............................................................................................................................. 18 LIST OF FIGURES Figure 1 Figure 2A-2E Figure 3A-3E Study Area Location Study Area Plan Areas of Potential Environmental Concern LIST OF TABLES Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Summary of Certificates of Approval Summary of Spill Occurrences Summary of Storage Tanks Summary of Registered Waste Generators Summary of Records of Site Condition Summary of Pesticide Register Summary of PCB Storage Sites Summary of National Pollutant Release Inventory Summary of Manufacturing Facilities Project No.: 10-6959 Page ii Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 EXECUTIVE SUMMARY McCormick Rankin Corporation, on behalf of the Regional Municipality of York in partnership with the Toronto Transit Commission and the City of Toronto, is undertaking a Conceptual Design and Functional Planning Study for a proposed extension of the Yonge Street subway. As such, Ecoplans Limited has been retained by MRC to conduct a Contamination Overview Study in support of the transit improvements to the Yonge Street subway, which include alignment alternatives, station locations and associated facilities. Based on the findings of this report, broad areas of potential environmental concern (APECs) are identified by Ecoplans. The red highlights on Figure 3A through Figure 3E illustrate the areas/activities that could result in potential soil and/or groundwater contamination. These areas are also briefly discussed in this section. • • • • • • Area 1 – This area consists of commercial activities located on the east side of Yonge Street between High Tech Road and Westwood Avenue. According to information obtained through Ecolog ERIS, fuel storage tanks and pesticide storage are located in this area. Area 2 - This area consists of commercial/industrial activities located on the east side of Yonge Street between Highway 407 and Thornheights Road. According to information obtained through Ecolog ERIS, fuel storage tanks, registered waste generators and manufacturing facilities are located in this area. Area 3 – This area consists of commercial activities located on the east and west sides of Yonge Street between Colonsay Road and Kirk Drive. According to information obtained through Ecolog ERIS, numerous fuel storage tanks and registered waste generators are located in this area. Area 4 – This area consists of commercial activities on the east and west sides of Yonge Street between Elgin Street and Centre Street. According to information obtained through Ecolog ERIS, numerous fuel storage tanks and registered waste generators are located in this area. Area 5 – This area consists of commercial facilities on the east and west sides of Yonge Street between Clark Avenue and Ontonabee Avenue. According to information obtained through Ecolog ERIS, numerous fuel storage tank, registered waste generators and pesticide storage sites are located in this area. Area 6 - This area consists of commercial facilities on the east and west sides of Yonge Street between Holmes Avenue and Centre Avenue. According to information obtained through Ecolog ERIS, numerous fuel storage tank, registered waste generators, pesticide storage sites and manufacturing facilities are located in this area. Recommendations It is recommended that a subsurface investigation (i.e. boreholes) be performed for the APECs identified prior to construction to determine the presence or absence of environmental impacts to soil and groundwater, and to assess the appropriate management of excess materials (contaminated and non-contaminated). The subsurface investigation can be performed in coordination with the geotechnical investigation, where feasible. The number and depth of boreholes required for each APEC identified will need to be determined on a case-by-case basis, and should take into consideration the proximity of the preferred route to land use activities Project No.: 10-6959 Page iii Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 suspected of having a potential for site contamination, the depth of proposed cuts, and geologic and hydrogeologic conditions. Based on the results of the subsurface investigation and the proposed earthworks excavations, an Excess Materials Management Plan (EMMP) should be developed prior to, and implemented during construction. The purpose of the EMMP is to provide a pragmatic approach to managing excess materials and groundwater generated during construction of the Yonge Subway with due regard to environmental regulations and guidelines (Ontario Regulation 347, Ontario Regulation 153/04, OPSS 180, and municipal sewer use by-laws). Excess materials that could be typically encountered during construction include earth and rock (contaminated and non-contaminated), concrete, asphalt and other extraneous solid material; and groundwater (contaminated and noncontaminated). Construction Impacts - as discussed above, the EMMP will be developed prior to construction to provide a mitigation strategy to effectively manage any contaminated excess materials (both soil and groundwater) encountered during construction. In addition to managing contaminated materials generated during construction, it is equally important to ensure that off-site contamination (i.e. contamination outside of the subway corridor excavation area) does not migrate back into the corridor. This may require engineered containment barriers/walls such as grout curtains and sheet piling; and/or hydraulic traps to contain, capture and treat contaminant plumes. These requirements must be integrated into the detail design of the subway corridor. Operations and Maintenance Impacts - depending on the whether there is a need to design and install any engineered contaminant barriers along the subway corridor (as outlined above), there will be associated long term operation and maintenance of the containment barriers which must be integrated into the operations and maintenance of the subway corridor. Project No.: 10-6959 Page iv Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 1.0 January 2009 INTRODUCTION McCormick Rankin Corporation (MRC), on behalf of the Regional Municipality of York in partnership with the Toronto Transit Commission (TTC) and the City of Toronto, is undertaking a Conceptual Design and Functional Planning Study for a proposed extension of the Yonge Street subway. As such, Ecoplans Limited (Ecoplans) has been retained by MRC to conduct a Contamination Overview Study (COS) in support of the transit improvements to the Yonge Street subway, which include alignment alternatives, station locations and associated facilities. Part of the process prior to commencing transit improvements includes determining the presence and significance of any actual or potential site contamination within the study area, which could have an impact on construction activities. A COS is intended as a “broad level assessment” of actual and potential sources of site contamination within a given area, and is based solely on the known current and former land uses/activities and secondary source information. This study is not a full environmental liability assessment of each property potentially impacted by the undertaking, and it does not constitute a Phase I Environmental Site Assessment (ESA) as defined by the Canadian Standards Association (CSA Z768-01), and Ontario Regulation 153/04 (O.Reg. 153/04). 1.1 Project Objective The principle objective of this COS is to identify areas/properties with actual or potential site contamination, which may impact construction activities. For the purposes of this study, contamination is defined as a material or condition present in the soil, groundwater, surface water, air or building materials that may have an adverse effect on human health or the environment. 1.2 Proposed Works The scope of work undertaken to complete this study included the following tasks: a) Records Review • Review of Physiographic, Geological and Hydrogeological Maps and Reports – to identify the general physiography, geology and hydrogeology within and surrounding the study area in an effort to understand the fate of any actual or potential site contamination. • Review of Existing Reports – to review any relevant environmental information previously collected for the study area. • Review of Aerial Photographs – to identify areas of potential environmental concern within and adjacent to the study area. • Review of Ministry of the Environment (MOE) Data – to review any previously collected information on former waste disposal sites, former coal gasification plants, brownfield sites registered under the Environmental Bill of Rights Registry (EBR), and polychlorinated biphenyl (PCB) storage sites located within the study area. • Review of Private Source Data – to provide relevant information on private and retail fuel storage tanks, automotive wrecking and supply facilities, Andersons Project No.: 10-6959 Page 1 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 waste disposal sites (including Certificates of Approval), and O.Reg. 347 registered waste generators. • Review of Municipal and Regional Data – to identify any potentially contaminated sites located within the study area. b) Study Area Inspection • Windshield Reconnaissance – to broadly identify properties that pose a potential for site contamination, either based on their nature of operations/land use (e.g. service stations, industrial areas) or by visual evidence of contamination (e.g. piles of waste, surface staining). c) Impact Assessment • Design Plan Review – to evaluate the proposed design plans and identify potential effects and proposed mitigation measures. d) Reporting • • • Compilation, Evaluation and Discussion of Key Findings – thorough review of all information gathered pertaining to the study area and undertaking. Conclusions and Recommendationsconcluding remarks on the presence/probability of actual or potential contamination within the study area, and recommendations for any follow-up work. Preparation of a Factual Report – written documentation of the results of the COS. Project No.: 10-6959 Page 2 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 2.0 PHYSICAL SETTING 2.1 Location and Size January 2009 The transit project is an underground 6.5 km, six subway station extension of the Yonge Street subway from its terminus at Finch Station in the City of Toronto to a proposed terminus in the Richmond Hill Centre (hereafter referred to as “study area”). For the purposes of this COS, the study area is bounded to the north by Bantry Avenue and to the south by Finch Avenue, and covers an east-west distance of approximately 500 metres from the centre-line of Yonge Street. Figure 1 illustrates the study area location. 2.2 Current Land Use The City of Toronto Land Use Map 16 (August 2007) identifies the study area south of Steeles Avenue as being “Mixed Use” along Yonge Street, surrounded by “Neighbourhood Use”. The designation of “Mixed Use” includes a mixture of commercial/retail and residential land use. The Region of York classifies the land use along Yonge Street north of Steeles Avenue as “Mixed Density Residential”, and “Commercial”. 2.3 Topography and Drainage The surficial topographic relief within and surrounding the study area is flat to gently sloping, with a southward decrease in elevation towards Lake Ontario. The average ground surface elevation ranges from 230 m above sea level (ASL) in the north portion of the study area, to approximately 185-190 m ASL in the south. The study area is located within the Don River Watershed. The East Don River crosses Yonge Street approximately 1.5 km south of the Highway 407 interchange, with a tributary crossing directly though (underneath) the interchange. Another tributary of the East Don River is enclosed in a pipe and flows southeast underneath Yonge Street north of Steeles Avenue. On a local scale, water runoff and precipitation is discharged to roadside drainage ditches, storm sewers, or local watercourses. 2.4 Physiography According to Chapman and Putnam’s “The Physiography of Southern Ontario” (1984), and the Ministry of Natural Resources (MNR) Map 2226 “Physiography of South Central Portion of Southern Ontario” (1972), the study area is falls within the physiographic region known as the Peel Plain. The Peel Plain is a level-to-undulating tract of clay soils and covers an area of approximately 777 km2. Many rivers and streams drain this region, and swamps and bogs are not common. Much of the Peel Plain has been modified by a veneer of clay. 2.5 Geology 2.5.1 Overburden Geology An investigation of hydrogeological conditions was conducted along Yonge Street from Steeles Avenue to 19th Avenue/Gamble Road, by Jagger Hims Limited in April 2003. According to secondary source information and field data collected, the study area primarily consists of surficial deposits of Newmarket Till. Newmarket Till is Project No.: 10-6959 Page 3 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 composed of dense sandy silt to sand. Fluvial deposits of sand, clay and muck are identified in the vicinity of the East Don River and its associated tributaries. 2.5.2 Bedrock Geology According to the Ontario Geological Survey (OGS) Map 2544 “Bedrock Geology of Southern Ontario” (1991), the study area is underlain by the Georgian Bay Formation. This formation is dominated by shales, but also has interbeds of limestone and siltstone. 2.6 Hydrogeology 2.6.1 Overburden Aquifer Newmarket Till South of the Oak Ridges Moraine (ORM), Newmarket Till is the primary surficial deposit. This unit is capable of producing only limited quantities of water, and acts as a confining layer to the sands and gravels of the (deeper) Thorncliffe Formation. Available groundwater in this till unit likely occurs in fractures caused by wetting and drying, and in sand and gravel lenses. The frequency and size of fractures will typically decrease with an increase in depth. Due to the generally fine-textured composition of the Newmarket Till, and the predominance of paved surfaces, infiltration and recharge is expected to be low within the study area. 2.6.2 Bedrock Aquifer According to Singer et al (2003), the Georgian Bay hydrogeologic unit is the main bedrock aquifer within and surrounding the study area. This unit consists predominantly of blue-grey shales with minor limestone and siltstone interbeds, and is generally regarded as a poor source of groundwater. The pore spaces in the dense shales of this hydrogeologic unit have relatively poor interconnections, and do not readily dissolve or fracture thus limiting its porosity. Project No.: 10-6959 Page 4 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 3.0 RECORDS REVIEW 3.1 Existing Reports January 2009 Ecoplans reviewed a contaminated property report prepared by Golder Associates Ltd (May 2003) for an Individual Environmental Assessment (EA) in York Region. The Individual EA was completed as part of the York Rapid Transit Plan, to assess route options along the Yonge Street corridor between Steeles Avenue and 19th Avenue. The purpose of the Golder report was to identify potential sources of contaminated materials along proposed routes being considered for future expansion of transit services. A summary of the key findings is presented below: • Three spill records were identified along Yonge Street between Centre Street and Highway 7. The spills were related to the release of coolant or diesel fuel. • Nine fuel storage tank records were identified through the Technical Standards and Safety Authority (TSSA) for 24 aboveground or underground storage tanks (ASTs or USTs) located along Yonge Street between Steeles Avenue and Bantry Avenue. • 37 properties with the potential for site contamination were identified along Yonge Street between Steeles Avenue and Bantry Avenue, during a visual reconnaissance. 21 properties were rated as having a high potential for contamination based on the nature of the land use and activity/operation observed, proximity to Yonge Street, and due diligence issues. The report made no recommendations for further environmental investigation. 3.2 Aerial Photographs Ecoplans reviewed historical aerial photographs of the study area for the year 1946, 1949, 1951, 1954, 1969, 1974, 1981 and 1988. The aerial photographs were obtained from the National Airphoto Library (NAPL) in Ottawa, Ontario. Ecoplans also reviewed aerial images for the year 2007, on Google Earth Pro. Ecoplans did not identify any sources of potential site contamination within the study area that were exclusive to the aerial photograph review. A summary of the observations made during the aerial photograph review are presented in below: • In 1946 the study area was largely agricultural with small residential areas located at Finch Avenue and Steeles Avenue along Yonge Street. • Between 1946 and 1951 residential development and basic commercial development increased within and surrounding the study area. • By 1954 Highway 401 was visible south of the study area. • Between 1954 and 1974 Highway 7 through York Region was completed, and residential and commercial expansion continued. • From 1974 through to 2007 the study area continued to expand and develop with a focus on residential and commercial land uses. Project No.: 10-6959 Page 5 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 3.3 January 2009 Ecolog ERIS Environmental and Historical Information Ecolog ERIS is a national database service, which provides environmental information for properties across Canada. The information provided contains Government of Canada and Environment Canada public records, and private sector records that provide information pertaining to environmental liabilities associated with the property in question and the surrounding area. Ecoplans requested that Ecolog ERIS search the following databases for the study area: • Certificates of Approval (1985-2002) • Ontario Spills (1988-2002) • Fuel Storage Tanks (current to 2007) • Private Fuel Storage Tanks (1989-1996) • Retail Fuel Storage Tanks (2000-2008) • Commercial Fuel Oil Tanks (1948-2008) • Waste Disposal Sites – MOE C of A Inventory (1970-2002) • Andersons Waste Disposal Sites (1930-2004) • Automobile Wrecking and Supplies (2001-2007) • Ontario Regulation 347 Waste Generators Summary (1986-2008) • Record of Site Condition (1997-2008) • Pesticide Register (1988-2007) • Ontario Inventory of PCB Storage Sites (1987-2004) • National PCB Inventory (1988-2004) • National Pollutant Release Inventory (1993-2006) • Scott’s Manufacturing Directory (1992-2008) • Federal Contaminated Sites and Solid Waste Landfills (2000-2007) Figure 2A through 2E shows the features identified in the Ecolog report. 3.3.1 Certificates of Approval (1988-2002) This database contains the following types of approvals: Certificates of Approval (C of A) for air issued under Section 9 of the Environmental Protection Act (EPA); C of A’s (industrial waste water) issued under Section 53 of the Ontario Water Resources Act (OWRA); and C of A’s (sewage and waterworks) issued under Sections 52 and 53 of the OWRA. A review of the C of A database revealed that there are 59 C of A’s filed for 47 properties within the study area. Table 1 includes a complete summary of the information obtained from the Ecolog report. Project No.: 10-6959 Page 6 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 3.3.2 January 2009 Commercial Fuel Oil Tanks (1948-2008) Since May 2002, Ontario developed a new act where it became mandatory for fuel oil tanks to be registered with the Technical Standards and Safety Authority (TSSA). This data would include all commercial underground fuel oil tanks in Ontario. A review of the Commercial Fuel Oil Tanks (CFOT) database revealed that there are three registered fuel oil tanks at three locations within the study area. Table 2 includes a complete summary of the information obtained from the Ecolog report. 3.3.3 Fuel Storage Tanks (current to 2007) The TSSA, under the Technical Standards and Safety Act, 2000, maintains a database of registered private and retail fuel storage tanks in Ontario. A review of the Fuel Storage Tanks (FST) inventory revealed that there are 15 registered tanks at 11 locations within the study area. Table 2 includes a complete summary of the information obtained from the Ecolog report. 3.3.4 Private and Retail Fuel Storage Tanks (1989-1996) The Fuels Safety Branch of the Ontario Ministry of Consumer and Commercial Relations (MCCR) maintained a database of all registered private fuel storage tanks. Public records of private fuel storage tanks are only available since the registration became effective in September 1989. This information is now collected by the TSSA. A review of the Private Fuel Storage Tanks (PST) inventory revealed that there are 31 registered tanks at 22 locations within the study area. Table 2 includes a complete summary of the information obtained from the Ecolog report. 3.3.5 Retail Fuel Storage Tanks (2000-2008) This database includes an inventory of retail fuel outlet locations that have on their property gasoline, oil, waste oil, natural gas and / or propane storage tanks. A review of the Retail Fuel Storage Tanks (RST) inventory revealed that there are ten registered tanks at ten locations within the study area. Table 2 includes a complete summary of the information obtained from the Ecolog report. 3.3.6 Ontario Spills (1988-2002) This database identifies action, types and sources of spills and approximate locations of the occurrences within Ontario. A review of the Ontario Spills database (SPL) revealed that there have been seven spills at six locations within the study area. Table 3 includes a complete summary of the information obtained from the Ecolog report. 3.3.7 Waste Disposal Sites – MOE C of A Inventory (1970-2002) The MOE, Waste Management Branch, maintains an inventory of known open (active or inactive) and closed disposal sites in the Province of Ontario. Active sites maintain a Certificate of Approval (C of A), are approved to receive and are receiving waste. Project No.: 10-6959 Page 7 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 Inactive sites maintain C of As but are not receiving waste. Closed sites are not receiving waste. The data contained within this database was compiled from the MOE's C of A database. A review of the MOE C of A inventory revealed that there are no registered waste disposal sites located within the study area. 3.3.8 Andersons Waste Disposal Sites (1930-2004) This database was created to identify sites which are missing from the Ontario MOE Waste Disposal Site Inventory and to correct site information in the MOE inventory. This databases also identifies auto wreckers and scrap yards. This database was compiled for research purposes and is not considered exhaustive. A review of the Andersons Waste Disposal Site Inventory revealed that there is one dumping area located within the study area. The disposal area was located at 24 Wedgewood Drive in Toronto in the 1950s. Based on a review of aerial photographs for 1950-1969, no evidence of large-scale disposal activities was observed. New residences were being constructed during this timeframe though, so it is likely that the dumping was related to construction debris or private disposal by one property owner. Given the they documented location of the disposal area is approximately 200 m east of Yonge Street and the MOE has no record of a landfill or disposal area located at 24 Wedgewood Drive (in their MOE C of A inventory), the potential for site contamination within the study is considered to be low. 3.3.9 Automobile Wrecking and Supplies (2001-2007) This database provides a list of all known locations that are involved in scrap metals, automobile wrecking, and auto parts and supplies industry. The inventory provides company name, location and business type. A review of the automobile wrecking and supplies inventory revealed that there are no automobile wrecking and supplies companies located within the study area. 3.3.10 Ontario Regulation 347 Waste Generators Summary (1986-2008) Ontario Regulation 347 of the Ontario EPA defines a waste generation site as any site, equipment and/or operation involved in the production, collection, handling and/or storage of regulated wastes. A generator of regulated waste is required to register the waste generation site and each waste produced, collected, handled, or stored at the site. This database contains the registration number, company name and address of registered generators including the types of hazardous wastes generated. This information includes data from 1986 to the most currently available data (i.e. 2005). A review of the waste generators inventory revealed that there are 271 registered waste generators at approximately 97 locations within the study area. Table 4 includes a complete summary of the information obtained from the Ecolog report. 3.3.11 Record of Site Condition (1997-2008) The Record of Site Condition (RSC) provides a summary of the final environmental condition of a site, once an ESA and/or restoration approach has been undertaken. The Project No.: 10-6959 Page 8 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study January 2009 database provides information on the site restoration approach used, location of contaminated site, whether contamination extends past 1.5 m from the surface thereby requiring “stratified restoration”, soil type, and the date when the RSC was submitted or responded to by the MOE. A review of the RSC inventory revealed that there are six properties with an RSC filed within the study area. Table 5 includes a complete summary of the information obtained from the Ecolog report. 3.3.12 Pesticide Register (1988-2007) The MOE maintains a database of all manufacturers and vendors of registered pesticides. A review of the pesticide (PES) inventory revealed that there are 41 companies registered for pesticides at 24 locations within the study area. Table 6 includes a complete summary of the information obtained from the Ecolog report. 3.3.13 Ontario Inventory of PCB Storage Sites (1987-2004) The MOE, Waste Management Branch, maintains an inventory of PCB storage sites within the Province. Ontario Regulation 11/82 (Waste Management - PCB) and Regulation 347 (Generator Waste Management) under the Ontario EPA requires the registration of inactive PCB storage equipment and/or disposal sites of PCB waste with the MOE. This database contains information on: 1) waste quantities; 2) major and minor sites storing liquid or solid waste; and 3) a waste storage inventory. A review of the Ontario PCB (OPCB) inventory revealed that there are five records for two PCB storage sites within the study area. Table 7 includes a complete summary of the information obtained from the Ecolog report. 3.3.14 National PCB Inventory (1988-2004) Environment Canada’s National PCB inventory (NPCB) includes information on in-use PCB containing equipment in Canada including federal, provincial and private facilities. A review of the NPCB inventory revealed that there are three properties with PCB containing equipment within the study area. Table 7 includes a complete summary of the information obtained from the Ecolog report. 3.3.15 National Pollutant Release Inventory (1993-2006) Environment Canada has defined the National Pollutant Release Inventory (NPRI) as a federal government initiative designed to collect comprehensive national data regarding releases to air, water, or land, and waste transfers of 178 specified substances. A review of the NPRI revealed that there are five records for one property within the study area. Table 8 includes a complete summary of the information obtained from the Ecolog report. Project No.: 10-6959 Page 9 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 3.3.16 January 2009 Scott’s Manufacturing Directory (1992-2008) Scott’s directory is a data bank containing information on over 70,000 manufacturers in Ontario. It is the most comprehensive database of Ontario manufacturers available. A review of the Scott’s Manufacturing Directory (SCT) revealed that there are 108 registered manufacturing companies within the study area. Table 9 includes a complete summary of the information obtained from the Ecolog report. 3.3.17 Federal Contaminated Sites and Solid Waste Landfills (2000-2007) The Treasury Board of Canada Secretariat (TBCS) maintains an inventory of all known contaminated sites held by various Federal departments and agencies. This inventory does not include properties owned by Crown corporations, but does contain nonfederal sites for which the Government of Canada has accepted some or all financial responsibility. All sites have been classified through a system developed by the Canadian Council of Ministers of the Environment (CCME). The database provides information on company name, location, site identification number, property use, classification, current status, contaminant type and plan of action for site remediation. A review of the Federal Contaminated Sites and Solid Waste Landfills (FCS) inventory revealed that there are no federal contaminated sites or solid waste landfills within the study area. Project No.: 10-6959 Page 10 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 4.0 January 2009 STUDY AREA INSPECTION Ecoplans carried out an inspection of the study area on December 5, 2008. The purpose of the inspection was to document land uses and/or business operations which may represent a potential source of site contamination within the study area (e.g. gas stations, auto repair facilities, industrial operations). The results of the study area inspection have been incorporated into this report. The land use activities noted between Finch Avenue and Bantry Avenue include: • Residential (condominiums, houses, apartments) • Transportation facilities (bus, subway, railway crossings) • Hydro electric facilities • Retail commercial (restaurants, grocery stores, shopping malls, coffee shops, etc.) • Gas stations • Car dealerships • Dry cleaning facilities • Automotive repair and maintenance facilities • Institutional facilities (schools, learning centres, cemeteries) • Recreational areas (parks, golf courses, etc.) • Commercial/industrial facilities (manufacturing) It should be noted that the inspection did not include any building inspections or comprehensive exterior inspections of any of the properties in the study area. Therefore, any interferences regarding the presence or absence of site contamination is strictly based on visual observations made from the roadside. Project No.: 10-6959 Page 11 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 5.0 January 2009 KEY FINDINGS OF STUDY Based on the information collected through this study Ecoplans did not identify any areas of actual site contamination within the study area. However, areas of potential environmental concern (APEC) were noted. The areas identified are discussed in more detail in the following sections, and are illustrated on Figure 3A through Figure 3E. 5.1 Potential Sources of Contamination 5.1.1 Commercial and Industrial Land Use Potential soil and groundwater contamination may exist within the study area as a result of current and historical commercial/industrial land uses. Below is a list of operations and activities associated with commercial/industrial land uses identified within the study area. • Fuel Storage Tanks – Automotive centres and gas stations may operate pump islands (USTs for storing fuel), small storage areas, and occasionally service areas for changing engine oil. Gasoline and diesel fuel are transferred from bulk container trucks to large USTs. Spills at transfer areas and pumps, along with overfilling of and leakage from the USTs, are potential sources of site contamination. • Manufacturing Facilities, Registered Waste Generators and PCB Storage Sites – A wide range of chemicals are used at facilities that manufacture and distribute parts/products for industrial and commercial use. These chemical products may include acids and bases, dyes and pigments, PCBs, polymers, plastics, surfactants, solvents, soaps, and waxes. These manufacturing processes are highly variable, depending on the product being produced. There are, however, certain types of process components that are frequently encountered in these facilities, including bulk storage for gaseous, liquid and solid materials, blending and packaging equipment, storage areas for drums, waste piles and disposal pits. The fact that an activity or operation appears on the above list does not mean hazardous substances are used or stored on all sites occupied by that activity or operation, nor that the land used will have hazardous substances present. 5.1.2 Historical Agricultural Operations A large proportion of the study area was dominated by agricultural operations until the mid-1950’s. Since then, significant development has occurred around the study area. The pesticides used in these agricultural operations can accumulate in the environment and remain for long periods of time. These contaminants can be transported through surface water runoff, wind and dust generation, and groundwater. However, Ecoplans believes that due to a decrease in the intensity of the agricultural operations and the change in land use overall, there is a low potential for soil and groundwater contamination associated with historical agricultural operations. Project No.: 10-6959 Page 12 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 5.2 January 2009 Contaminant Mobility Contaminants on or in the soils may move within and beyond the study area through a number of different routes. The soils themselves retain contaminants through adsorption. The movement of contaminants from soil occurs through evaporation and dust generation, intake into plants through their roots, and by flushing or dissolution intro water seeping into the soil. Water transport of chemicals will usually result in contamination of surface water bodies through surface water drainage, and by way of groundwater aquifers. In general, contaminant mobility will be greatest when: 5.2.1 • Overburden deposits consist of sand and gravel, or other permeable deposits. • Fractured bedrock is located at or near the surface, or is overlain by a thin layer of permeable deposits. • Distance to surface water courses is less than 50 m. • Water table is less than 5 m below ground surface (bgs). • Preferential flow pathways (e.g. trenches, tree roots, ditches) exist in the soils above the water table. Significance of Mobility within the Study Area The surficial geology is largely composed of Halton Till, which is made up of varying proportions of silt and clay. These deposits tend to act as confining materials, inhibiting the lateral and vertical movement of contaminants. This can result in increased time for natural attenuation process to occur. The bedrock geology of the study area is primarily composed of shale associated with the Georgian Bay Formation. Shale bedrock is considered to be a poor source of potable water, and is not likely tapped as a significant source of water within the study area. In addition, the bedrock is overlain by alternating layers of silt and clay with low permeability. This will significantly hinder the movement of contaminants into the bedrock aquifer system. Also, the large extent of paved surfaces will direct most runoff to storm sewers, and will further act as a barrier to contaminant migration. Overall, based on the known geologic and hydrogeologic conditions present within the study area, the inferred mobility of any contamination will likely be low. Project No.: 10-6959 Page 13 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 6.0 January 2009 AREAS OF POTENTIAL ENVIRONMENTAL CONCERN Based on the findings of this report, broad areas of potential environmental concern (APECs) are identified by Ecoplans. These areas have been categorized by assessing the overall relative potential of contamination from the findings in Section 2.0 through Section 5.0. The red highlights on Figure 3A through Figure 3E illustrate the areas/activities that could result in potential soil and/or groundwater contamination. These areas are also briefly discussed in this section. • Area 1 – This area consists of commercial activities located on the east side of Yonge Street between High Tech Road and Westwood Avenue. According to information obtained through Ecolog ERIS, fuel storage tanks and pesticide storage are located in this area. • Area 2 - This area consists of commercial/industrial activities located on the east side of Yonge Street between Highway 407 and Thornheights Road. According to information obtained through Ecolog ERIS, fuel storage tanks, registered waste generators and manufacturing facilities are located in this area. • Area 3 – This area consists of commercial activities located on the east and west sides of Yonge Street between Colonsay Road and Kirk Drive. According to information obtained through Ecolog ERIS, numerous fuel storage tanks and registered waste generators are located in this area. • Area 4 – This area consists of commercial activities on the east and west sides of Yonge Street between Elgin Street and Centre Street. According to information obtained through Ecolog ERIS, numerous fuel storage tanks and registered waste generators are located in this area. • Area 5 – This area consists of commercial facilities on the east and west sides of Yonge Street between Clark Avenue and Ontonabee Avenue. According to information obtained through Ecolog ERIS, numerous fuel storage tank, registered waste generators and pesticide storage sites are located in this area. • Area 6 - This area consists of commercial facilities on the east and west sides of Yonge Street between Holmes Avenue and Centre Avenue. According to information obtained through Ecolog ERIS, numerous fuel storage tank, registered waste generators, pesticide storage sites and manufacturing facilities are located in this area. Project No.: 10-6959 Page 14 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 7.0 January 2009 RECOMMENDATIONS It is important to identify and characterize environmental impacts early in the study process in order to develop effective mitigation measures and worker health and safety protocols prior-to and during construction. As such, it is recommended that a subsurface investigation (i.e. boreholes) be performed for the APECs identified prior to construction to determine the presence or absence of environmental impacts to soil and groundwater, and to assess the appropriate management of excess materials (contaminated and non-contaminated). The subsurface investigation can be performed in coordination with the geotechnical investigation, where feasible. The number and depth of boreholes required for each APEC identified will need to be determined on a case-by-case basis, and should take into consideration the proximity of the preferred route to land use activities suspected of having a potential for site contamination, the depth of proposed cuts, and geologic and hydrogeologic conditions. Based on the results of the subsurface investigation and the proposed earthworks excavations, an Excess Materials Management Plan (EMMP) should be developed prior to, and implemented during construction. The purpose of the EMMP is to provide a pragmatic approach to managing excess materials and groundwater generated during construction of the Yonge Subway with due regard to environmental regulations and guidelines (Ontario Regulation 347, Ontario Regulation 153/04, OPSS 180, and municipal sewer use by-laws). Excess materials that could be typically encountered during construction include earth and rock (contaminated and non-contaminated), concrete, asphalt and other extraneous solid material; and groundwater (contaminated and non-contaminated). Construction Impacts - as discussed above, the EMMP will be developed prior to construction to provide a mitigation strategy to effectively manage any contaminated excess materials (both soil and groundwater) encountered during construction. In addition to managing contaminated materials generated during construction, it is equally important to ensure that off-site contamination (i.e. contamination outside of the subway corridor excavation area) does not migrate back into the corridor. This may require engineered containment barriers/walls such as grout curtains and sheet piling; and/or hydraulic traps to contain, capture and treat contaminant plumes. These requirements must be integrated into the detail design of the subway corridor. Operations and Maintenance Impacts - depending on the whether there is a need to design and install any engineered contaminant barriers along the subway corridor (as outlined above), there will be associated long term operation and maintenance of the containment barriers which must be integrated into the operations and maintenance of the subway corridor. Project No.: 10-6959 Page 15 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 9.0 January 2009 QUALIFICATIONS OF THE ENVIRONMENTAL CONSULTANT Ecoplans Limited, established in 1970, provides consulting services in the biological and physical sciences, environmental planning, landscape architecture, environmental impact assessment, and environmental site assessment and remediation. Ecoplans staff includes specialists in all facets of the environmental field. The Environmental Site Assessment and Remediation Division of Ecoplans Limited specializes in Phase I, II and III Environmental Site Assessments, electromagnetic surveys, aboveground and underground storage tank removals/assessments, groundwater investigations and site remediation/restoration. Ecoplans has completed numerous Phase I and Phase II Environmental Site Assessments for both the public and private sector. Some of our clients include the Ministry of Transportation, GO Transit, Ontario Realty Corporation, Regional Municipality of Peel, Greater Toronto Airports Authority, Medallion Properties Inc., and Marshall-Barwick Inc. Mr. Derek Stewart, M.Sc., P.Geo, as Senior Hydrogeologist, is the head of Ecoplans’ Environmental Site Assessment & Remediation Division. Mr. Stewart has over 16 years experience carrying out site assessments and remediation projects working for a number of environmental consulting firms. He has been with Ecoplans since 1996. At the project level, Mr. Stewart provides technical and editorial support to his staff, and peer reviews all draft and final reports prior to being sent to the client. Mr. Neil Levesque, B.E.S., CCEP, is an Environmental Consultant with Ecoplans' Environmental Site Assessment and Remediation group. Mr. Levesque has over seven years of experience as an environmental consultant in the areas of groundwater resources/physical hydrogeology, contaminated property mitigation, environmental site assessments, and Class EA consultation and documentation. He has significant experience working on transportation planning and infrastructure projects in both the public and private sectors, and has provided project coordination and technical expertise for numerous complex assignments across Ontario. Mr. Levesque is experienced in interpreting and applying a wide range of environmental regulations, standards, and policies to various projects. Project No.: 10-6959 Page 17 Yonge Street Subway Extension – Finch Avenue Northerly to Bantry Avenue Conceptual Design and Functional Planning Study Contamination Overview Study 10.0 January 2009 REFERENCES Chapman, L.J. and Putnam, D.F. 1984. The Physiography of Southern Ontario, 3rd Edition. Ontario Geological Survey, Special Vol.2, 270p. Chapman, L.J. and Putnam, D.F. 1984. Physiography of Southern Ontario. Ontario Geological Survey, Map 2715, Scale 1:600,000. Golder Associates Ltd. 2003. Contaminated Property Report. York Rapid Transit Plan. Golder Associates Ltd. 2005. Preliminary Geotechnical Report. York Rapid Transit Plan. LGL Limited. 2005. Natural Sciences Report: Yonge Street Transitway. York Rapid Transit Plan. National Airphoto Library, Aerial Photographs: 1946, 1960, 1963, 1969, 1974, 1978, 1980 and 1988. Ottawa, Ontario. Ontario Geological Survey. 1991. Bedrock Geology of Ontario, Southern Sheet. Ontario Geological Survey, Map 2544, Scale 1:1,000,000. Singer, S.N., Cheng, C.K., and Scafe, M.G. 2003. Hydrogeology of Southern Ontario, Second Edition. Environmental Monitoring and Reporting Branch, Ontario Ministry of the Environment, 200p. Project No.: 10-6959 Page 18 FIGURES ³ Scale: 1:50,000 Source: National Topographic Series Map 30M/05 - Burlington CONTAMINATION OVERVIEW STUDY YONGE SUBWAY EXTENSION STUDY AREA LOCATION DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 1 T STREE D ROA E L RVIL C T E ENU EN E AV RUC NT SCE E R YC E AV AD IT VAN T OUR UR CO AD C TON S L O D ROA N A C DUN L MAP E RO RO ILLE V R CAR VE HA T 6 1 E NU K SIL C ISAN PLA CAR SP ³ E YONG DENAVA GATE UE ! ! GEN-15 SCT-4 PRT-1 P RI CA-11 ! ! ! SCT-3 ! CA-9 CA-10 GEN-5 SCT-2 E DRIV TON CLIN GEN-6 T CEN R ES C DS LAN L E E RIV LEV ND E D LIN ER V L I S T CEN RES C LIAM WIL E G KIN ENU V A OR REG G C MA DRIVE E REET GEN-8 CA-7 CA-6 SCENT T ERE S RST-2 NC E IRK SELK M ELLES UE VEN A K OA NU AVE R A EDG E RG CR COBU CA-12 TR E PA NU AVE K IC ! GEN-4 GEN-3 ! COUR SCT-1 ! NE ! CA-3 CA-5 CA-4 PES-1 RO VE SON A PEAR IVE NT SCE E R C OOD AD E DR RIDG LE AP DM RE CLA ! ! ! RST-1 FST-1 ! RO A TECH H G I H GEN-2 GEN-7 RST-3 E ! CA-1 GEN-9 NOR LEA D CA-2 CA-8 NUE I VE T DR L E SEV ROO N YW SUN T IVE Y DR A K MAC LA OD O W T WES ENUE Y AV R T N BA BAFFIN IVE T DR T O SC CLE CIR UE VEN A N DE GAR Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT (PES) Pesticide Register Railroad Line ! (ANDR) Anderson's Waste Disposal Sites ! ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River Subway Alignment STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION STUDY AREA PLAN DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 2-A VE SON A PEAR UE VEN A N DE GAR 7 AY HW G I H ! NUE T CEN S E R AC EID N O FST-3 LE BOY ³ 7 WAY HIGH E OAD R F AF GS T N A L E DRIV !! ! CA-17 7 40 GEN-17 GEN-19 GEN-18 GEN-25 SCT-6 SCT-7 ! D R OA F F A GST CA-19 LAN Y7 HWA G I H ! ! GEN-26 OPCB-1 SCT-5 PES-2 ! ! ! E VENU LES A CA-18 ENUE E V EN U IEW A Y WA H G HI 07 Y4 A W GH I H CA-13 RUGG CA-14 CA-15 CA-16 W AV V FAIR IE GEV YON ! ! AST ! ! SCT-8 ! GEN-28 PES-4 PES-3 GEN-29 ! GEN-32 GEN-34 E YONG NUE AVE FEE THO ET STRE BUNKER RO E RIV KD R A M NOR ! N SCE E ENU T E LAC SP I M GLA ! GEN-35 ! VE DRI ! PRT-4 PRT-5 RST-4 PRT-2 V DS A N A UPL D ROA S T H E IG RNH K KIR AD ! ! CRE SCT-9 VE DRI ARD LE V BOU RIVE FT D I W S STA SHA W AVIE VIST IDLE D ROA R ALIE CAV LO GE RID N GB GEN-33 ! GEN-36 SCT-10 ! SCT-11 HEL EN NUE AVE ! ! BAY AL DON VE DRI N GEN-38 R GEN-37 THO E ENU SCT-12 BO UL E VA RD ENUE EA AV FAIRL RI VE RS ID E ! ! GEN-41 SCT-13 NT D ROA Y A ON S COL RST-5 AV HILL N R THO N BAI S CE CRE E SILV ! GEN-42 GEN-44 R E RI V ND E P AS GEN-43 CA-20 GEN-45 ! ! SCT-14 GEN-56 PES-6 PES-5 GEN-57 Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT (PES) Pesticide Register Railroad Line ! (ANDR) Anderson's Waste Disposal Sites ! ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River Subway Alignment STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION STUDY AREA PLAN DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 2-B B AY LE APP D HAR ORC H PAT WI LL GEN-61 OW E YONG GEN-60 GEN-62 ³ E IV IN G EP WE ! CH R D WIL GEN-57 D PES-5 NE N SCT-14 GEN-56 PES-6 Y LA E RR R O ! TH ! NE LA T STREE ! MILL ST RE FST-4 PRT-6 ET ! FST-5 GEN-66 GEN-68 OLD SCT-15 ! G YON RN THO GEN-67 OAD KR N A B ES OAD KR BAN ET TRE ELM GEN-73 ! ! EET STR E URN ! GEN-72 PRT-8 ! PRT-7 SCT-16 SCT-17 E LAN EET CA-23 ST R E JAN CFOT-1 CA-22 E LAN E G A VINT ! LE DUD CA-25 ! GEN-75 ! OKE BRO ! EL S GIN E TRE T PES-7 PRT-10 ! E STR PES-8 GEN-82 GEN-81 ET PES-9 ! D ROA RD EVA MIRA NG OUL GEN-80 GEN-88 GEN-90 GEN-89 LD WAY I SPR EB GAT T OUR RST-6 FIE SPRING NUE AVE D L O ARN EC AI N ! E ENU ! ! ALC Y AV GEN-74 PRT-9 IVE DR E G RID SCT-18 N OR TH E DRIV REET JOHN ST ! ! T REE T S TRE CEN CA-24 CH BO! COL ES ARL NK NBA DEA NUE AVE K R CLA ! OR MAN N E GL NUE AVE K R CLA WAY ! PES-11 T WES PRT-11 ! PES-10 ! AV AN G R MO E ENU FST-7 PRT-12 ! CA-26 ! ! ! Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT (PES) Pesticide Register Railroad Line ! (ANDR) Anderson's Waste Disposal Sites ! ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River Subway Alignment STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION STUDY AREA PLAN DATE: JANUARY 20092008 DECEMBER PROJECT: 10-6959 FIGURE 2-C CLA RK A V ! PRT-12 FST-7 ! WES T ! LEY ENU E ! CA-26 DIN WIN ! GEN-92 NE G LA SCT-20 SCT-22 SCT-21 CA-27 CA-29 SCT-35 SCT-38 SCT-34 CA-28 SCT-41 NC DO EET E STR YONG T CEN RES C NNA JOA ! SCT-42 SCT-43 ! SCT-46 SCT-44 SCT-47 GEN-108 DOW MEA GEN-107 ! ! GEN-118 ! POW PRT-14 ELL NT SCE CRE ! CA-33 ! PRT-15 D R OA OD WO ! GEN-120 IE NDV A R G D AV WAR GEN-121 RST-7 ! CA-34 E ENU D VAR E L BOU STE ! S AN ! ! PRT-19 RST-8 FST-8 CA-35 S ELE ST E EA U N AVE I LILL PRT-18 D ROA PES-14 D O O STW CRE UE VEN A W K PAR D N HLA HIG SCT-49 ET STRE ENUE EY AV DUDL ER DBE BRA GEN-117 GEN-119 VIE UE VEN A W LL JEWE SCT-48 CA-30 CA-31 ! E ! PRT-13 VE DRI D O WO PINE AS U EN AV R TE ! ! CA-32 ³ OAD NR O R AME NC E L G ! ! ! GEN-93 E ENU ! NUE AVE SCT-19 GEN-91 AV GAN R O M DUD NUE AVE K R CLA ! ! CA-36 ET TRE GEN-123 GEN-125 ! GEN-124 ! PES-16 PES-15 ! PRT-24 ! ! AV LES E E T SSCT-55 ESTPRT-25 ! EW U N E GEN-126 IG O NIP UE VEN A I TIB CA-37 ABI ! GEN-128 ! GEN-132 PES-19 GEN-131 GEN-138 PRT-26 PRT-27 CA-38 GEN-129 GEN-136 ! ! ! ! ! GEN-152 ABA ATH ! ! UE VEN A A SK NAB OTO ! ! GEN-157 GEN-155 GEN-156 ! SCT-59 ! ! V DRI N O T NEW SCT-61 ! PES-28 CA-40 PES-30 ! ! GEN-159 GEN-160 !GEN-162 GEN-163 GEN-161 VEN GA N I D L GOU ! D ROA RE E ENU IVIE LAR A AV NUE AVE K PAR NUE AVE T N ASA PLE NUE AVE GO FAR HILD RE MOO SEN GEN-167 SCT-63 GEN-166 E SCT-62 SCT-60 PES-29 E! MA NU AVE A K AS DAW EET STR SCT-58 UE VEN A E E ONT DUM RT COU ! GEN-146 GEN-147 PES-20 SCT-56 SCT-57 CA-39 PES-23 PES-25 PES-27 PES-26 E ENU EN GRE TAN ! S CRO PES-17 ! GEN-130 VE DRI PES-18 SCT-51 SCT-50 ! GEN-135 E ENU N AV E AV DAL LOW WIL RST-9 CE ! UE ! E AV NTR E ENU ! ! OOD HW T R NO CA-41 GEN-165 SPL-1 V DRI E ! ! Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT (PES) Pesticide Register Railroad Line ! (ANDR) Anderson's Waste Disposal Sites ! ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River Subway Alignment STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION STUDY AREA PLAN DATE: FIGURE JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 2-D G ! ! ! CA-42 SCT-63 GEN-165 SPL-1 GEN-166 GEN-167 ER E ENU D AV ! ! CA-43 SCT-64 SCT-65 ! ! SCT-66 SCT-67 SCT-72 GEN-175 HAM GEW WED OOD VE DRI ! ! ! ! ANDR-1 DOV SCT-73 HILD UE VEN A T GH NAU N O C TH NOR RT CO U VE DRI D O WO ! ! O AD UE VEN A A I RIC PAT RING EVE EET E STR YONG ! R VIE OO EW M O H ! I LAR N LDI GOU N UE AVE NUE AVE GO FAR PLE ! E ENU V A NT ASA OOD ERW ! COU A AV CUM ³ RT NUE AVE R ME GEN-176 E E NU GEN-178 GEN-177 ! ! ! ! ! GEN-183 GEN-181 GEN-191 GEN-190 GEN-192 ! LD CHI FAIR GEN-197 Y WR DRE ! ! GEN-201 GEN-202 SCT-74 FST-9 GEN-205 SCT-75 GEN-196 ET TRE NUE AVE S KE BUR CA-44 AD T RO E L MUL ! ! GEN-198 GEN-195 AVE ! SPL-2 ! NUE CA-46 CA-45 AVE ! GEN-184 Z INE U CO RT NT SCE E R C RILL ! ! ! ! PES-31 ! ! PES-32 GEN-208 PES-34 GEN-209 GEN-207 SCT-76 CA-47 FST-12 SCT-77 PES-33 ! ! VE DRI ANK RBPES-36 E PES-35 BOW ! ! CA-48 GEN-213 SPL-4 SPL-3 OPCB-5 N LTO R A CH LE BOU ! OPCB-4 D VAR ! ! ! ! GEN-229 SCT-78 PES-37 CA-49 GEN-230 SCT-79 ! NUECA-50 AVE P HO BIS ! ! GEN-231 BE PEM FST-13 FST-14 GEN-236 ELIN MAD E RO ! ! GEN-242 ! GEN-243 NUE D H AV SCT-85 ! SCT-94 ! SCT-93 ! ! CFOT-3 CA-55 NU AVE E V I OL CA-54 ! ! NPCB-3 ! GEN-254 GEN-253 SCT-96 GEN-252 UE VEN A S ME HOL ! ! GEN-255 ! E RIV ED N I RA LOR UE VEN A G BYN ! ! SCT-98 ! U BO GEN-261 RSC-5 SPL-7 ! RSC-4 ! ! CA-58 GEN-268 RSC-6 GEN-267 R OLM C L HO O AD TA SAN B BAR R ARA ! O AD UE VEN A OW NSL U O H ! UE VEN HA NE T VE DRI ALE THV RD P FO M E K ! KEN SCT-108 EDI ARD LEV SCT-106 ! GEN-257 GEN-256 E ENU IS AV DOR AD SCT-99 SCT-107 E ! PES-38 ! RSC-2 FST-15 RST-10 PES-40 PRT-31 RSC-3 PES-41 SCT-97 CA-57 C FIN SCT-87 SCT-92 CA-56 ST WE CA-52 SCT-88 ! GEN-244 PRT-30 SCT-95 ! CA-53 SCT-84 SCT-86 UE AVEN T ROA ! ! ! CA-51 ! ! VIEW RSC-1 NUE A AVE TALBO R ELDO UE VEN A N E EX AV DUPL SPL-6 DO HEN E ENU ! GEN-234 ! NUE AVE LEY DUD SPL-5 E N GREE K BLA E NU E AV ! ! GEN-233 NUE AVE N RTO ! UE VEN A M GEN-269 GEN-271 CA-59 GEN-270 SHA HOR NUE AVE H RC CHU Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT (PES) Pesticide Register Railroad Line ! (ANDR) Anderson's Waste Disposal Sites ! ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River Subway Alignment STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION STUDY AREA PLAN DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 2-E EET E STR YONG DENAVA GATE D ROA E L RVIL COL T E ENU SP EN E AV RUC NT SCE E R YC E AV AD IT VAN T OUR UR CO AD NC STO D ROA N A C DUN L MAP E RO RO ILLE V R CAR UE K SIL C ISAN PLA CAR VEN HA T 6 1 ³ UE ! ! GEN-15 SCT-4 PRT-1 CA-11 M ELLES ! ! SCT-3! CA-9 CA-10 REET E GEN-5 SCT-2 GEN-6 CLIN NU AVE R A EDG ! GEN-8 CA-7 CA-6 T CEN R ES C DS LAN L E VE DRI LEV N E LIND ER V L I S T CEN RES C AM ILLI W E G KIN ENU V A OR REG G C MA DRIVE T ERE S RST-2 SCENT UE VEN A K OA NC E IRK SELK E RG CR COBU P RI CA-12 TR E PA NU AVE K IC E DRIV TON ! GEN-4 GEN-3 ! COUR SCT-1 ! NE CA-5 ! CA-3 AREA 1 CA-4 PES-1 RO VE SON A PEAR IVE NT SCE E R C OOD AD E DR RIDG LE AP DM RE CLA ! ! ! RST-1 FST-1 ! GEN-7 RST-3 RO A TECH H G I H GEN-2 E ! CA-1 GEN-9 C NOR A E L D CA-2 CA-8 NUE I VE T DR L E SEV ROO N YW SUN T IVE Y DR A K MAC LA OD O W T WES ENUE Y AV R T N BA BAFFIN SCO RIVE TT D LE IRC N AVE N E D GAR UE Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT ! (ANDR) Anderson's Waste Disposal Sites ! (PES) Pesticide Register Railroad Line Subway Alignment ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Potential Area of Environmental Concern Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION AREAS OF POTENTIAL ENVIRONMENTAL CONCERN DATE: JANUARY 20092008 DECEMBER PROJECT: 10-6959 FIGURE 3-A UE VEN A N DE GAR 7 AY HW G I H ! T CEN S E CR DA I E ON FST-3 BOY LE ³ 7 WAY HIGH E OAD R F AF GS T N A L E DRIV !! ! E YONG ET STRE ENUE E V EN U IEW A Y WA H G HI 07 Y4 A W GH HI CA-13 CA-17 CA-18 ! 7 40 GEN-17 GEN-19 GEN-18 E VENU LES A RUGG CA-14 CA-15 CA-16 W AV V FAIR IE GEV YON ! ! AST ! ! GEN-25 ! GEN-26 OPCB-1 SCT-5 PES-2 SCT-6 SCT-7 ! ! AREA 2 D R OA F F A GST CA-19 LAN Y7 HWA G I H SCT-8 ! ! ! GEN-28 PES-4 PES-3 GEN-29 ! GEN-32 GEN-34 NUE AVE FEE THO BUNKER RO VE DRI K R MA NOR ! N SCE E ENU T E LAC SP I M GLA ! GEN-35 ! VE DRI ! PRT-4 PRT-5 RST-4 PRT-2 V DS A N A UPL D ROA S T H E IG RNH K KIR AD ! ! CRE SCT-9 VE DRI ARD LE V BOU IVE T DR F I SW STA SHA W AVIE VIST IDLE D ROA R ALIE CAV LO GE RID N GB GEN-33 ! GEN-36 SCT-10 ! SCT-11 E ENU V A EN HEL ! ! BAY AL DON VE DRI N GEN-38 R GEN-37 THO E ENU SCT-12 BO UL E VA RD ENUE EA AV FAIRL RI VE RS ID E ! ! GEN-41 SCT-13 NT D ROA Y A ON S COL RST-5 AV HILL N R THO N BAI S CE CRE AREA 3 ER SILV ! GEN-43 GEN-44 E RI V ND E P AS GEN-42 CA-20 GEN-45 ! ! SCT-14 GEN-56 PES-6 PES-5 GEN-57 Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT ! (ANDR) Anderson's Waste Disposal Sites ! (PES) Pesticide Register Railroad Line Subway Alignment ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Potential Area of Environmental Concern Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION AREAS OF POTENTIAL ENVIRONMENTAL CONCERN DATE: FIGURE JANUARY 20092008 DECEMBER PROJECT: 10-6959 3-B ! IN G EP WE ! H PAT ³ OW GEN-61 LE APP D HAR ORC LL WI E YONG GEN-60 GEN-62 CH E IV D WIL GEN-57 R D PES-5 NE N SCT-14 GEN-56 PES-6 Y LA E RR R ! O BO UL EV AR D TH SI DE AY ER B RI V NE LA T STREE ! MILL ST RE FST-4 PRT-6 ET ! FST-5 GEN-66 GEN-68 OLD ! G YON RN THO GEN-67 OAD KR N A B SCT-15 ES OAD KR BAN ET TRE ELM AREA 4 ! ! ! GEN-73 RNE !U O B COL PRT-8 ! PRT-7 SCT-16 CH SCT-17 ES ARL E LAN EET CA-23 ST R E JAN CFOT-1 CA-22 AGE VINT ! LE DUD CA-25 ! GEN-75 ! OKE BRO TR IN S ELG EET PES-7 PRT-10 ! PES-8 GEN-82 GEN-81 PES-9 MIRA ! D ROA NG OUL ! GEN-88 GEN-90 GEN-89 LD WAY I SPR EB GAT RD EVA GEN-80 FIE SPRING NUE AVE D L O ARN RT RST-6 EET STR ! OU EC AI N E LAN ! E ENU ! E IDG R N SCT-18 OR TH ALC Y AV GEN-74 PRT-9 IVE DR E DRIV REET JOHN ST ! ! EET ST R E R T CEN CA-24 EET STR NK NBA A E D NUE AVE K R CLA ! R ANO M N GLE EN K AV R A CL UE WAY NUE AVE N GA MOR ! PES-11 PRT-11 T W ES PES-10 ! FST-7 ! PRT-12 ! CA-26 ! ! ! ! SCT-19 SCT-20 Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT ! (ANDR) Anderson's Waste Disposal Sites ! (PES) Pesticide Register Railroad Line Subway Alignment ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Potential Area of Environmental Concern Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION AREAS OF POTENTIAL ENVIRONMENTAL CONCERN DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 3-C ³ ! NUE AVE K R CLA PES-11 ! RK A V PRT-12 ENU E PES-10 ! DUD CLA FST-7 WES T ! LEY ! ! CA-26 L DING WIN ! GEN-92 ANE OAD NR O R AME NC E L G ! ! SCT-22 ! GEN-93 E ENU ! NUE AVE SCT-19 GEN-91 AV GAN R O M SCT-21 CA-27 CA-29 CA-28 SCT-35 SCT-38 SCT-34 SCT-41 NC DO E YONG T CEN RES C NNA JOA ! AREA 5 ! GEN-108 DOW MEA GEN-107 ! ! ! E NUE EY AV DUDL ER DBE BRA GEN-118 ! POW ! PRT-14 ELL NT SCE CRE ! PRT-15 D R OA VE DRI OD WO PINE GEN-117 GEN-119 ! GEN-120 ! OD WO IE NDV A R G D AV WAR GEN-121 RST-7 ! CA-34 E ENU ARD LEV U O KB ST E EA U N VE ES A L E STE I LILL PRT-18 ! ! ! PRT-19 RST-8 FST-8 CA-35 S AN D ROA PES-14 D O O STW CRE UE VEN A W PAR ND A L H HIG SCT-49 ET STRE PRT-13 VIE UE VEN A W LL JEWE ET STRE SCT-42 SCT-43 ! SCT-46 SCT-44 SCT-47 CA-33 E ! SCT-48 CA-30 CA-32 CA-31 AS U EN AV R TE ! CA-36 ET TRE GEN-123 GEN-125 ! GEN-124 ! PES-16 PES-15 ! PRT-24 ! ! V ES A L E TE SSCT-55 ESTPRT-25 ! EW U N E GEN-126 IG O NIP ! GEN-128 ! GEN-132 PES-19 GEN-131 GEN-138 PRT-26 PRT-27 CA-38 GEN-129 GEN-136 ! ! GEN-152 ABA ATH ! ! ! UE VEN A A SK NAB OTO ! ! GEN-157 GEN-155 GEN-156 ! SCT-59 ! ! V DRI TON W NE SCT-61 ! PES-28 CA-40 PES-30 ! ! GEN-159 GEN-160 !GEN-162 GEN-163 GEN-161 VEN GA N I D L GOU ! D ROA RE E ENU NUE AVE GO FAR A AV NUE AVE K PAR NUE AVE T N ASA PLE IVIE LAR D HIL RE MOO SEN GEN-167 SCT-63 E SCT-62 SCT-60 PES-29 E! MA NU AVE A K AS DAW EET STR SCT-58 UE VEN A E E ONT DUM RT COU ! GEN-146 GEN-147 PES-20 SCT-56 SCT-57 CA-39 PES-23 PES-25 PES-27 PES-26 ! A ! UE VEN A I B CA-37 BITI E ENU EN GRE TAN ! S CRO PES-17 ! GEN-130 VE DRI PES-18 SCT-51 SCT-50 ! GEN-135 E ENU N AV E AV DAL LOW WIL RST-9 CE ! UE ! E ENU ! ! CA-41 GEN-165 GEN-166 E AV NTR SPL-1 ! ! ! OOD HW T R T NO O UR C HAM RING E V E V DRI E Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT ! (ANDR) Anderson's Waste Disposal Sites ! (PES) Pesticide Register Railroad Line Subway Alignment ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Potential Area of Environmental Concern Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION AREAS OF POTENTIAL ENVIRONMENTAL CONCERN DATE: FIGURE JANUARY 20092008 DECEMBER PROJECT: 10-6959 3-D AS PLE A ! E ENU V A NT N UE GEN-167 ! CA-43 OAD UE VEN A A I RIC PAT SCT-65 SCT-67 ANDR-1 HILD N AVE GO FAR UE VEN SCT-72 AGEN-175 T H G SCT-73 NAU CON DOV OOD ERW ! RT E E NU UE A AV NUE AVE R ME GEN-177 ! ! ! LD CHI FAIR GEN-197 ! ET TRE NUE AVE S KE BUR CA-44 ! GEN-201 GEN-202 SCT-74 FST-9 GEN-205 SCT-75 GEN-196 O ZC INE UR T NT SCE E R C RILL AD T RO E L MUL ! ! GEN-198 GEN-195 AVE ! GEN-191 GEN-190 GEN-192 ! NUE CA-46 CA-45 AVE ! GEN-184 SPL-2 ! ! ! ! ! PES-31 ! ! PES-32 GEN-208 PES-34 GEN-209 GEN-207 SCT-76 CA-47 FST-12 SCT-77 PES-33 ! ! VE DRI ANK RBPES-36 E PES-35 BOW ! ! CA-48 GEN-213 SPL-4 SPL-3 OPCB-5 OPCB-4 A RD L EV ! ! ! AREA 6 ! ! GEN-229 SCT-78 PES-37 CA-49 GEN-230 SCT-79 ! NUECA-50 AVE P HO BIS ! ! GEN-231 BE PEM FST-13 FST-14 E EX AV E RO ! ! GEN-242 ! GEN-243 ! CFOT-3 SCT-92 SCT-94 ! SCT-93 ! ! CA-55 NU AVE E V I OL CA-54 ! ! NPCB-3 ! GEN-254 GEN-253 SCT-96 GEN-252 CA-56 ELIN MAD H AV SCT-87 GEN-244 NUE D UE VEN A S ME HOL ! ! GEN-255 ! E RIV ED N I RA LOR UE VEN A G BYN ! ! SCT-99 GEN-261 U BO RSC-5 SPL-7 ! ! RSC-4 ! ! CA-58 GEN-268 RSC-6 GEN-267 O AD ! TA SAN B BAR ARA D RO A N HOU VE WA SL O NUE ! NUE AVE M SHA HOR UE MR CO L L O H ! VEN HA NE T VE DRI ALE THV RD P FO M E K ! KEN SCT-108 EDI ARD LEV SCT-106 ! GEN-257 GEN-256 E ENU IS AV DOR SCT-98 SCT-107 E ! PES-38 ! RSC-2 FST-15 RST-10 PES-40 PRT-31 RSC-3 PES-41 AD C FIN CA-52 SCT-88 ! SCT-85 PRT-30 SCT-95 ! NUE AVE LEY DUD DUPL CA-53 SCT-84 SCT-97 CA-57 ST WE ! ! CA-51 SCT-86 GEN-236 UE AVEN T ROA ! SPL-6 ! ! VIEW RSC-1 NUE A AVE TALBO R ELDO DO HEN UE VEN A N NUE AVE N RTO ! GEN-234 ! E ENU ! ! GEN-233 SPL-5 E N GREE K BLA ³ GEN-176 GEN-183 E NU E AV VE DRI GEN-178 GEN-181 N LTO R A CH COU CUM ! BOU OOD ! ! ! Y WR DRE VE ! ! ! ! SCT-66 DRI GEW WED ! ! ER UE ! ! OD WO RT CO U HAM RING E V E EET E STR YONG R VIE N AVE D O O TH NOR GEN-165 SCT-63 GEN-164 SPL-1 GEN-166 I LAR EW HOM VE GA ! ! ! CA-42 N LDI GOU ! GEN-269 GEN-271 CA-59 GEN-270 CH NU AVE H C UR E Legend Ecolog ERIS ! (NPRI) National Pollutant Release Inventory Property Boundary Yonge Street Subway SOURCE ! (OPCB) Inventory of PCB Storage Sites Watercourse ELEMENT ! (ANDR) Anderson's Waste Disposal Sites ! (PES) Pesticide Register Railroad Line Subway Alignment ! (CA) Certificates of Approval ! (PRT) Private and Retail Fuel Storage Tanks Potential Area of Environmental Concern Alternative 1 - A ! (CFOT) Commercial Fuel Oil Tanks ! (RSC) Record of Site Condition Platform ! (FST) Fuel Storage Tanks ! (RST) Retail Fuel Storage Tanks Tunnel ! (GEN) Ontario Regulation 347 Waste Generators Summary ! (SCT) Scott's Manufacturing Directory Cross Over ! (NPCB) National PCB Inventory ! (SPL) Ontario Spills East Don River STAPTS Scale: 1:6,000 Source: Google Earth Imagery CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION AREAS OF POTENTIAL ENVIRONMENTAL CONCERN DATE: JANUARY 2009 DECEMBER 2008 PROJECT: 10-6959 FIGURE 3-E TABLES Page 1 of 18 TABLE 1 SUMMARY OF CERTIFICATES OF APPROVAL CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID CA-1 CA-2 CA-3 CA-4 CA-5 CA-6 CA-7 CA-8 CA-9 CA-10 CA-11 CA-12 CA-13 CA-14 CA-15 CA-16 CA-17 CA-18 CA-19 CA-20 CA-21 CA-22 CA-23 CA-24 CA-25 CA-26 CA-27 CA-28 CA-29 CA-30 CA-31 CA-32 CA-33 CA-34 CA-35 CA-36 CA-37 CA-38 Company Name Unknown Unknown Yonge Bayview Holdings Inc. Yonge Bayview Holdings Inc. Yonge Bayview Holdings Inc. Richmond Hill Centre - Langstaff Planning Richmond Hill Centre - Langstaff Planning R.J. Davies Holdings Ltd. Andy Guizzetti Limited Andy Guizzetti Limited Town of Richmond Hill Town of Richmond Hill Richmond Hill Centre Ontario Clean Water Agency City of Vaughan Ministry of the Environment and Energy Yonge Bayview Holdings Inc. Town of Richmond Hill Town of Richmond Hill Service Corporation International (Canada) Unknown Nexacor Realty Nexacor Realty City of Vaughan City of Vaughan D.M. Consultants Limited MDS Health Group Limited MDS Health Group Limited Unknown North York Chevy Oldsmobile Ltd. Roy Foss Motors Ltd. North York Chevy Oldsmobile Ltd. Ancona Inc. Petro Canada Central Business Centre Vetmar Limited Metro Toronto Works Department North York Centre Revenue Properties Company Limited Address 50 High Tech Road 50 High Tech Road Westwood Lane and Yonge Street Westwood Lane and Yonge Street Westwood Lane and Yonge Street Edgar Avenue and Yonge Street Edgar Avenue and Yonge Street Yonge Street Frontier Drive and Edgar Avenue Frontier Drive and Edgar Avenue Oak Avenue and Yonge Street Oak Avenue and Yonge Street Highway 7 and Yonge Street Highway 7 and Yonge Street Highway 7 and Yonge Street Highway 7 and Yonge Street Highway 7 and Yonge Street Boyle Road and Langstaff Road Langstaff Road and Yongeview Avenue Yonge Street Lot 5, Concession 1, Colbourne Street, Eliza St. 7700 Yonge Street 7700 Yonge Street Thornbank Road and Centre Street Thornridge Drive and Yonge Street Clark Avenue and Yonge Street 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 7200 Yonge Street 7200 Yonge Street 7200 Yonge Street 7120 Yonge Street 7092 Yonge Street 7064 Yonge Street Willowdale Boulevard and Steeles Avenue Dumont Street and Anitibi Street 6464 Yonge Street 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls City Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill City of Vaughan Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill Town of Richmond Hill City of Vaughan City of Markham City of Vaughan City of Vaughan City of Vaughan City of Vaughan City of Vaughan City of Markham City of Markham City of Markham City of Markham City of Markham City of Vaughan City of Vaughan City of Vaughan City of Vaughan City of Markham City of North York City of North York Approval Type Industrial Air Industrial Air Municipal Sewage Municipal Water Municipal Sewage Municipal Water Municipal Sewage Municipal Sewage Municipal Sewage Municipal Water Municipal Sewage Municipal Water Municipal Sewage Municipal Sewage Municipal Water Municipal Water Municipal Sewage Municipal Water Municipal Water Municipal Sewage Municipal and Private Water Industrial Air Industrial Air Municipal Sewage Municipal Water Municipal Sewage Industrial Air Industrial Air Industrial Air Industrial Air Industrial Air Industrial Air Industrial Air Industrial Wastewater Municipal Sewage Municipal Water Municipal Sewage Industrial Air January 2009 Page 2 of 18 TABLE 1 SUMMARY OF CERTIFICATES OF APPROVAL CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID CA-39 CA-40 CA-41 CA-42 CA-43 CA-44 CA-45 CA-46 CA-47 CA-48 CA-49 CA-50 CA-51 CA-52 CA-53 CA-54 CA-55 CA-56 CA-57 CA-58 CA-59 Company Name Golden Rooster Cafateria City of North York City of North York City of North York Albertos Trattoria Drewry Avenue Inc. Drewry Avenue Inc. Drewry Avenue Inc. Toronto Hydro Unknown Fairchild Transformer Station City of North York City of North York City of North York City of North York Bell Canada City of North York City of Toronto City of North York City of North York Eminent Construction Ltd. Address 6307 Yonge Street Moore Park Avenue and Yonge Street Goulding Avnenue and Yonge Street Goulding Avnenue and Yonge Street 6068 Yonge Street Fairchild Avenue and Drewry Avenue Fairchild Avenue and Drewry Avenue Fairchild Avenue and Drewry Avenue 5800 Yonge Street Yonge Street 5750 Yonge Street Bishop Avenue and Kenneth Avenue Bishop Avenue and Yonge Street Pemberton Avenue and Kenneth Avenue Pemberton Avenue and Kenneth Avenue 31 Finch Avenue Finch Avenue and Yonge Street Finch Avenue and Lorraine Drive Finch Avenue and Eldora Drive Bying Avenue and Yonge Street 5385 Yonge Street City City of North York City of North York City of North York City of North York City of North York City of Toronto City of Toronto City of Toronto City of Toronto City of Toronto City of Toronto City of North York City of North York City of North York City of North York City of North York City of North York City of Toronto City of North York City of North York City of North York Approval Type Industrial Air Municipal Water Municipal Sewage Municipal Sewage Industrial Air Municipal Sewage Municipal Sewage Municipal Water Industrial Air Municipal Sewage Municipal Sewage Municipal Water Municipal Water Municipal Sewage Municipal Sewage Industrial Air Municipal Sewage Municipal Water Municipal Water Municipal Sewage Industrial Air Notes: CA - Certificate of Approval 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 3 of 18 TABLE 2 SUMMARY OF SPILL OCCURRENCES CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID SPL-1 SPL-2 SPL-3 SPL-4 SPL-5 SPL-6 SPL-7 Company Name Miller Transit Limited Unknown Unknown Midas of Walton Enterprises Toronto Transit Commission Unknown City of Toronto Location of Spill Centre Point Mall and Yonge Street Outfall of Silver Creek near Yonge Street and Cummer Avenue 5793 Yonge Street 5793 Yonge Street 5714 Yonge Street Bishop Avenue and Yonge Street 28 Byng Avenue Nature of Impact 40 L of coolant to ground Paint thinner odours from outfall Engine oil to ground Oil and liquid to catchbasin 300 L of mineral oil to ground Transmission fluid to ground 10 L of hydraulic oil to ground Environmental Impact Surface water pollution Surface water pollution Unknown Surface water pollution Soil contamination Unknown Unknown Notes: SPL - spill L - litres 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 4 of 18 TABLE 3 SUMMARY OF STORAGE TANKS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID FST-1 FST-2 FST-3 FST-4 FST-5 FST-6 FST-7 FST-8 FST-9 FST-10 FST-11 FST-12 FST-13 FST-14 FST-15 PRT-1 PRT-2 PRT-3 PRT-4 PRT-5 PRT-6 PRT-7 PRT-8 PRT-9 PRT-10 PRT-11 PRT-12 PRT-13 PRT-14 PRT-15 PRT-16 PRT-17 PRT-18 PRT-19 PRT-20 PRT-21 PRT-22 PRT-23 Company Name Sarah Enterprises International Inc. Global Fuels Inc. Shell Canada Products Thornhill Country Club Thornhill Country Club 4 Star Automotive Technical Club 1184187 Ontario Inc. Canadian Tire Corp. Budget Rent-A-Car Budget Rent-A-Car Toronto Hydro Toronto Hydro Jean L Veilleux Ltd. Jean L Veilleux Ltd. Veejay Inc. Richvale Block and Ready Mix Inc. Ciccone Leonardo Ferris Dry Car Repair Centre Ltd. Unknown Gregs Service Centre Ltd. Thornhill Country Club 689755 Ontario Ltd. Accel Motors Peck Brothers Ltd. Thornhill ESSO Sunoco Laviolette Enterprises Sunys Petroleum Northtown Ford Rebel Gas Bar Jon Oprea Petro Canada Services Jon Oprea Canadian Tire Corp. U-Sell 1080266 Ontario Limited 1080266 Ontario Limited Unknown Address 8830 Yonge Street 9076 Yonge Street 8656 Yonge Street 39 Mill Street 39 Mill Street 7738 Yonge Street 7377 Yonge Street 7161 Yonge Street 5870 Yonge Street 5870 Yonge Street 5800 Yonge Street 5800 Yonge Street 105 King Street 105 King Street 5571 Yonge Street 9137 Yonge Street 8243 Yonge Street 8248 Yonge Street 8248 Yonge Street. 8248 Yonge Street 39 Mill Street 7738 Yonge Street 7738 Yonge Street 7545 Yonge Street 7562 Yonge Street 7377 Yonge Street 7377 Yonge Street 7171 Yonge Street 7120 Yonge Street 7115 Yonge Street 7092 Yonge Street 7092 Yonge Street 7092 Yonge Street 7161 Yonge Street 7064 Yonge Street 7015 Yonge Street 7015 Yonge Street 7015 Yonge Street. City Richmond Hill Richmond Hill Richmond Hill Thornhill Thornhill Thornhill Thornhill Thornhill North York North York Toronto Toronto Unknown Unknown North York Richmond Hill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill North York Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Willowdale Operation Type Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Gas station Private fuel outlet Gas station Gas station Gas station Private fuel outlet Gas station Gas station Gas station Gas station Gas station Unknown Gas station Gas station Propane conversion centre Gas station Gas station Gas station Propane refill centre Gas station Propane refill centre Gas station Propane refill centre Unknown 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls Number of Tanks 4 5 2 2 2 4 4 4 1 1 1 1 3 3 6 1 Unknown Unknown Unknown Unknown 1 1 1 Unknown 1 1 1 Unknown 1 1 Unknown Unknown 1 Unknown 1 1 1 Unknown Tank Type Gasoline UST Gasoline (4) and diesel (1) UST Gasoline UST Gasoline (1) and diesel (1) UST Gasoline (1) and diesel (1) UST Gasoline UST Gasoline UST Gasoline UST Gasoline UST Gasoline UST Gasoline UST Gasoline UST Gasoline (2) and diesel (1) UST Gasoline (2) and diesel (1) UST Gasoline UST Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown January 2009 Page 5 of 18 TABLE 3 SUMMARY OF STORAGE TANKS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID PRT-24 PRT-25 PRT-26 PRT-27 PRT-28 PRT-29 PRT-30 PRT-31 RST-1 RST-2 RST-3 RST-4 RST-5 RST-6 RST-7 RST-8 RST-9 RST-10 CFOT-1 CFOT-2 CFOT-3 Company Name Servacar Limited Superior Propane Y W L and Company Jai Durga Enterprises Budget Rent-A-Car Hydro Electric Company Auto Service Ltd. Floro Enterprises Sunoco York Truck Centra Honda Richmond Hill Leo's Auto Service Petroleum Ltd. Mr. Lube Petro Canada Services Canadian Tire Gas Bar ESSO ESSO Tiger Express Bell Canada Palmer Cleaners Bell Canada Address 7015 Yonge Street 7015 Yonge Street 6355 Yonge Street 6355 Yonge Street 5870 Yonge Street 5800 Yonge Street 11 Finch Avenue 5571 Yonge Street 8830 Yonge Street 9076 Yonge Street 8800 Yonge Street 8243 Yonge Street 8125 Yonge Street 7562 Yonge Street 7092 Yonge Street 7161 Yonge Street 7015 Yonge Street 5571 Yonge Street 7700 Yonge Street 6050 Yonge Street. 31 Finch Avenue City Thornhill Thornhill North York North York North York North York North York North York Richmond Hill Richmond Hill Richmond Hill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill North York Thornhill North York North York Operation Type Unknown Unknown Gas station Unknown Private fuel outlet Private fuel outlet Gas station Gas station Gas station Gas station Oil changes and lubrication Gas station Oils Oil changes and lubrication Gas station Gas station Gas station Gas station NA NA NA Number of Tanks Unknown 1 1 Unknown 1 1 Unknown 1 Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown 1 1 1 Tank Type Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Fiberglass reinforced plastic Steel Fiberglass reinforced plastic Notes: FST - fuel storage tank PRT - private and retail fuel storage tank RST - retail storage tank CFOT - commercial fuel oil tank UST - underground storage tank NA - not applicable 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 6 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID GEN-1 GEN-2 GEN-3 GEN-4 GEN-5 GEN-6 GEN-7 GEN-8 GEN-9 GEN-10 GEN-11 GEN-12 GEN-13 GEN-14 GEN-15 GEN-16 GEN-17 GEN-18 GEN-19 GEN-20 GEN-21 GEN-22 GEN-23 GEN-24 GEN-25 GEN-26 GEN-27 GEN-28 GEN-29 GEN-30 GEN-31 GEN-32 GEN-33 GEN-34 GEN-35 GEN-36 GEN-37 GEN-38 GEN-39 GEN-40 GEN-41 GEN-42 GEN-43 GEN-44 GEN-45 GEN-46 GEN-47 GEN-48 GEN-49 GEN-50 GEN-51 GEN-52 GEN-53 GEN-54 GEN-55 Company Name Region of York Region of York Surf Marine Ltd. Surf Marine Ltd. Scholastic Canada Ltd. Scholastic Canada Ltd. Falconbridge Ltd. (out of business) D and S Equipment Davies Harley Davidson Richvale Block & Ready-Mix Richvale Block & Ready-Mix Richvale Block & Ready-Mix Richvale Block & Ready-Mix Richvale Block & Ready-Mix Richvale Block & Ready-Mix Dominion Caulking Limited Dominion Caulking Limited Ron Leuschner Spraying Ltd. Dominion Caulking Limited Deep Foundations Contractors Inc. Deep Foundations Contractors Inc. Deep Foundations Contractors Inc. Deep Foundations Contractors Inc. Deep Foundations Contractors Inc. Deep Foundations Contractors Inc. Cooper Machine & Tool Co. Walters Landscaping Limited Walters Landscaping Limited Core Concrete Ltd. Holy Cross Cemetery Holy Cross Cemetery Holy Cross Cemetery Holy Cross Cemetery Holy Cross Cemetery York Region District School Board Ace 1 Hour Photo Markham Hydro Electric Commission Markham Hydro Electric Commission J and P Cleaners J and P Cleaners J and P Cleaners Service Corporation (Canada) Ltd. Jerrett Funeral Home Jerrett Funeral Home Service Corporation (Canada) Ltd. Chorndale Cleaners Ltd. Chorndale Cleaners Ltd. Chorndale Cleaners Ltd. Chorndale Cleaners Ltd. Orchard Cleaners Orchard Cleaners Shoppers Drugmart Shoppers Drugmart Great A and P Co. Chorndale Cleaners Ltd. Address 50 High Tech Road 50 High Tech Road 9002 Yonge Street 9002 Yonge Street 9050 Yonge Street 9050 Yonge Street 8810 Yonge Street 9076 Yonge Street 8779 Yonge Street 9137 Yonge Street 9137 Yonge Street 9137 Yonge Street 9137 Yonge Street 9137 Yonge Street 9137 Yonge Street 73 Langstaff Road 73 Langstaff Road 73 Langstaff Road 73 Langstaff Road 29 Ruggles Avenue 29 Ruggles Avenue 29 Ruggles Avenue 29 Ruggles Avenue 29 Ruggles Avenue 29 Ruggles Avenue 25 Ruggles Avenue 10 Ruggles Avenue 10 Ruggles Avenue 9 Langstaff Road 8361 Yonge Street 8361 Yonge Street 8361 Yonge Street 8361 Yonge Street 8361 Yonge Street 8210 Yonge Street 8175 Yonge Street 227 Baythorn Drive 227 Baythorn Drive 8100 Yonge Street 8100 Yonge Street 8100 Yonge Street 8088 Yonge Street 8088 Yonge Street 8088 Yonge Street 8064 Yonge Street 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls City Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Thornhill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Richmond Hill Thornhill Thornhill Vaughan Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Thornhill Thornhill Thornhill Markham Thornhill Thornhill Thornhill Thornhill Vaughan Thornhill Markham Markham Thornhill Thornhill Thornhill Vaughan Thornhill Thornhill Vaughan Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Thornhill Markham Thornhill January 2009 Page 7 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID GEN-56 GEN-57 GEN-58 GEN-59 GEN-60 GEN-61 GEN-62 GEN-63 GEN-64 GEN-65 GEN-66 GEN-67 GEN-68 GEN-69 GEN-70 GEN-71 GEN-72 GEN-73 GEN-74 GEN-75 GEN-76 GEN-77 GEN-78 GEN-79 GEN-80 GEN-81 GEN-82 GEN-83 GEN-84 GEN-85 GEN-86 GEN-87 GEN-88 GEN-89 GEN-90 GEN-91 GEN-92 GEN-93 GEN-94 GEN-95 GEN-96 GEN-97 GEN-98 GEN-99 GEN-100 GEN-101 GEN-102 GEN-103 GEN-104 GEN-105 GEN-106 GEN-107 GEN-108 GEN-109 GEN-110 Company Name Bell Canada Bell Canada Thornhill Golf and Country Club Thornhill Golf and Country Club Thornhill Golf and Country Club Thornhill Golf and Country Club Thornhill Golf and Country Club Thornhill Golf and Country Club Ladies Golf Club of Toronto Ltd. Ladies Golf Club of Toronto Ltd. Ladies Golf Club of Toronto Ltd. Ladies Golf Club of Toronto Ltd. Ladies Golf Club of Toronto Ltd. Stephenson's Rent-All Inc. Stephenson's Rent-All Inc. Stephenson's Rent-All Inc. Stephenson's Rent-All Inc. Stephenson's Rent-All Inc. Hertz Canada Ltd. Hertz Canada Ltd. Imperial Oil Ltd. Imperial Oil Ltd. Imperial Oil Ltd. Imperial Oil Ltd. Imperial Oil Ltd. York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education York Region Board of Education RDS Diagnostics Healthwise Diagnostics Inc. Healthwise Diagnostics Inc. Normac Kitchens Limited Normac Kitchens Limited MDS Laboratories Lester Inks & Chemicals Ltd. Lester Inks & Chemicals Ltd. Sciex (out of bus) Sciex (out of bus) EMX Enterprises Autocars North 1983 Inc. Autocars North 1983 Inc. Eli Graphics and Printing Eli Graphics and Printing Eli Graphics and Printing Ministry of Revenue Ministry of Revenue SJL Holdings Limited SJL Holdings Limited Address 24 Royal Orchard Boulevard 24 Royal Orchard Boulevard 7994 Yonge Street 7994 Yonge Street 7994 Yonge Street 7994 Yonge Street 7994 Yonge Street 39 Mill Street 7859 Yonge Street 7859 Yonge Street 7859 Yonge Street 7859 Yonge Street 7859 Yonge Street 7756 Yonge Street 7756 Yonge Street 7756 Yonge Street 7756 Yonge Street 7756 Yonge Street 7545 Yonge Street 7545 Yonge Street 7562 Yonge Street 7562 Yonge Street 7562 Yonge Street 7562 Yonge Street 7562 Yonge Street 7554 Yonge Street 7554 Yonge Street 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 167 Dudley Avenue 7330 Yonge Street 12 Morgan Avenue 12 Morgan Avenue 59 Glen Cameron Road 59 Glen Cameron Road 59 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 39 Glen Cameron Road 33 Glen Cameron Road 33 Glen Cameron Road 11 Glen Cameron Road 11 Glen Cameron Road 11 Glen Cameron Road 55 Doncaster Avenue 55 Doncaster Avenue 7171 Yonge Street 7171 Yonge Street 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls City Markham Markham Thornhill Thornhill Markham Thornhill Thornhill Vaughan Thornhill Thornhill Thornhill Thornhill Thornhill Vaughan Vaughan Vaughan Vaughan Vaughan Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Markham Markham Thornhill Thornhill Thornhill Thornhill Vaughan Thornhill Thornhill Markham Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Markham Thornhill Thornhill Thornhill Markham Markham January 2009 Page 8 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID GEN-111 GEN-112 GEN-113 GEN-114 GEN-115 GEN-116 GEN-117 GEN-118 GEN-119 GEN-120 GEN-121 GEN-122 GEN-123 GEN-124 GEN-125 GEN-126 GEN-127 GEN-128 GEN-129 GEN-130 GEN-131 GEN-132 GEN-133 GEN-134 GEN-135 GEN-136 GEN-137 GEN-138 GEN-139 GEN-140 GEN-141 GEN-142 GEN-143 GEN-144 GEN-145 GEN-146 GEN-147 GEN-148 GEN-149 GEN-150 GEN-151 GEN-152 GEN-153 GEN-154 GEN-155 GEN-156 GEN-157 GEN-158 GEN-159 GEN-160 GEN-161 GEN-162 GEN-163 GEN-164 GEN-165 Company Name SJL Holdings Limited SJL Holdings Limited SJL Holdings Limited Hy and Zels Superior Dry Cleaners Superior Dry Cleaners Superior Dry Cleaners 1493237 Ontario Inc. 1493237 Ontario Inc. Midwifery Care Midwifery Care Smith Veterinary Hospital Smith Veterinary Hospital Smith Veterinary Hospital Smith Veterinary Hospital Consumers Gas Company Shanana Cleaners Shanana Cleaners Dr. Amir Rouzati Shanana Cleaners Loblaws Zellers Pharmacy Limited X-press Cleaners X-press Cleaners Quickly Discount Cleaners Ltd. Quickly Discount Cleaners Ltd. Hudsons Bay Company Hudsons Bay Company Black Photo Corporation Black Photo Corporation Black Photo Corporation Black Photo Corporation Black Photo Corporation Black Photo Corporation Black Photo Corporation Black Photo Corporation Shoppers Drugmart G.C. LOH Merchandising Ltd. Loblaws National Grociers Company North york Hydro Metcap Living P.P.A. Holdings Ltd. P.P.A. Holdings Ltd. Jerret Funeral Homes Jerret Funeral Homes Jerret Funeral Homes Glidden Paints Glidden Paints Glidden Paints R.S. Kane Funeral Home R.S. Kane Funeral Home R.S. Kane Funeral Home Yorke Town Decorating Supplies Ltd. Yorke Town Decorating Supplies Ltd. Address 7171 Yonge Street 7171 Yonge Street 7171 Yonge Street 7171 Yonge Street 34 Doncaster Avenue 34 Doncaster Avenue 34 Doncaster Avenue 34 Doncaster Avenue 34 Doncaster Avenue 7089 Yonge Street 7089 Yonge Street 8 Highland Park Boulevard 8 Highland Park Boulevard 8 Highland Park Boulevard 8 Highland Park Boulevard Part of Lot 27, Concession 1 100 Steeles Avenue 100 Steeles Avenue 100 Steeles Avenue 100 Steeles Avenue 6600 Yonge Street 6600 Yonge Street 180 Steeles Avenue 180 Steeles Avenue 180 Steeles Avenue 180 Steeles Avenue 6500 Yonge Street 6500 Yonge Street Steeles Avenue and Yonge Street 6440 Yonge Street Steeles Avenue and Yonge Street Steeles Avenue and Yonge Street Steeles Avenue and Yonge Street Steeles Avenue and Yonge Street 6440 Yonge Street Steeles Avenue and Yonge Street 6428 Yonge Street 6310 Yonge Street 6220 Yonge Street 6220 Yonge Street 6220 Yonge Street 15 Tangreen Court 6267 Yonge Street 6267 Yonge Street 6191 Yonge Street 6191 Yonge Street 6191 Yonge Street 6125 Yonge Street 6125 Yonge Street 6125 Yonge Street 6150 Yonge Street 6150 Yonge Street 6150 Yonge Street 6120 Yonge Street 6120 Yonge Street 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls City Markham Markham Markham Vaughan Markham Markham Markham Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Vaughan Thornhill Vaughan Thornhill Thornhill North York Toronto Vaughan Thornhill Thornhill Thornhill Willowdale Toronto Markham North York Markham North York Markham Markham North York Markham North York North York North York North York North York Toronto Willowdale Willowdale North York North York North York North York Willowdale North York North York North York North York Willowdale Willowdale January 2009 Page 9 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID GEN-166 GEN-167 GEN-168 GEN-169 GEN-170 GEN-171 GEN-172 GEN-173 GEN-174 GEN-175 GEN-176 GEN-177 GEN-178 GEN-179 GEN-180 GEN-181 GEN-182 GEN-183 GEN-184 GEN-185 GEN-186 GEN-187 GEN-188 GEN-189 GEN-190 GEN-191 GEN-192 GEN-193 GEN-194 GEN-195 GEN-196 GEN-197 GEN-198 GEN-199 GEN-200 GEN-201 GEN-202 GEN-203 GEN-204 GEN-205 GEN-206 GEN-207 GEN-208 GEN-209 GEN-210 GEN-211 GEN-212 GEN-213 GEN-214 GEN-215 GEN-216 GEN-217 GEN-218 GEN-219 GEN-220 Company Name Elite Studio City of Toronto Arnold Palmer Cleaner Arnold Palmer Cleaner Arnold Palmer Cleaner Basic Fuel Alternatives KWIK Copy KWIK Copy KWIK Copy KWIK Copy Connaught Yonge Square Limited Connaught Yonge Square Limited Connaught Yonge Square Limited Sketchley Cleaning Services Sketchley Cleaning Services Sketchley Cleaning Services Sedona Commercial Inc. North York Hydro North York Hydro New Cleaners Y and D Cleaners Success Dry Cleaner Success Dry Cleaner Success Dry Cleaner New Cleaners Y and D Cleaners Success Dry Cleaner North York Board of Education North York Board of Education Toronto District School Board Toronto District School Board North York Board of Education Great A and P Co. Family Cleaners Family Cleaners Family Cleaners Family Cleaners Budget Rent a Car Budget Rent a Car Shoppers Drugmart 657319 Ontario Ltd. Craico Limited Craico Limited Craico Limited North York Hydro Toronto Hydro Electric System Limited Toronto Hydro Electric System Limited Boiler Treatment.Com Ontario Hydro Ontario Hydro Ontario Hydro Ontario Hydro Ontario Hydro Ministry of the Environment and Energy Silmen Developments Ltd. Address 6118 Yonge Street 45 Goulding Avenue 6050 Yonge Street 6050 Yonge Street 6050 Yonge Street 6026 Yonge Street 6024 Yonge Street 6024 Yonge Street 6024 Yonge Street 6024 Yonge Street 6000 Yonge Street 6000 Yonge Street 6000 Yonge Street 5926 Yonge Street 5926 Yonge Street 5926 Yonge Street 5933 Yonge Street 38 Cummer Avenue 38 Cummer Avenue 13 Drewry Avenue 13 Drewry Avenue 13 Drewry Avenue 13 Drewry Avenue 13 Drewry Avenue 13 Drewry Avenue 13 Drewry Avenue 5906 Yonge Street 70 Drewry Avenue 70 Drewry Avenue 70 Drewry Avenue 70 Drewry Avenue 70 Drewry Avenue 5915 Yonge Street 5861 Yonge Street 5861 Yonge Street 5861 Yonge Street 5861 Yonge Street 5870 Yonge Street 5870 Yonge Street 5845 Yonge Street 5809 Yonge Street 5809 Yonge Street 5809 Yonge Street 5809 Yonge Street 5800 Yonge Street 5800 Yonge Street 5800 Yonge Street 5795 Yonge Street 5760 Yonge Street 700 University Avenue 5760 Yonge Street 5760 Yonge Street 700 University Avenue 5775 Yonge Street 5775 Yonge Street 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls City North York Toronto North York North York North York Toronto North York North York North York North York North York Toronto North York Willowdale Willowdale Willowdale Toronto North York North York North York North York Toronto Toronto Toronto North York North York Toronto North York North York Toronto Toronto North York North York Willowdale Willowdale North York Willowdale Willowdale Willowdale North York North York North York North York North York North York Toronto Toronto Toronto Willowdale Toronto North York North York Toronto North York North York January 2009 Page 10 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID GEN-221 GEN-222 GEN-223 GEN-224 GEN-225 GEN-226 GEN-227 GEN-228 GEN-229 GEN-230 GEN-231 GEN-232 GEN-233 GEN-234 GEN-235 GEN-236 GEN-237 GEN-238 GEN-239 GEN-240 GEN-241 GEN-242 GEN-243 GEN-244 GEN-245 GEN-246 GEN-247 GEN-248 GEN-249 GEN-250 GEN-251 GEN-252 GEN-253 GEN-254 GEN-255 GEN-256 GEN-257 GEN-258 GEN-259 GEN-260 GEN-261 GEN-262 GEN-263 GEN-264 GEN-265 GEN-266 GEN-267 GEN-268 GEN-269 GEN-270 GEN-271 Company Name Ministry of the Environment and Energy Ministry of the Environment and Energy Silmen Developments Ltd. Silmen Developments Ltd. Ontario Hydro Ontario Hydro Ministry of the Environment and Energy Belair Direct Corporation Ministry of the Environment and Energy Hydro One MTCC 805 Mac-Crete Holdings Inc. Toronto Transit Commission Toronto Transit Commission Ministry of Health Metropolitan Toronto Condominium Corporation 788 O&Y Enterprise O&Y Enterprise Edgecombe Group Inc. Enterprise Commercial Management Inc. Enterprise Commercial Management Inc. Manulife Financial General Property Services Inc. Enterprise Inc. Pharma Plus Drugs Ltd. Pharma Plus Drugs Ltd. Pharma Plus Drugs Ltd. North American Life Assurance Co. North American Life Assurance Co. Bell Canada Bell Canada Famous Cleaners Famous Cleaners Famous Cleaners Aries Painting Attic Typesetting Inc. Attic Typesetting Inc. Metropolitan Separate School Board Metropolitan Separate School Board St Cyril Catholic School Metropolitan Separate School Board Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Stephenson's Rent-All Ltd. Hi-tech Co. Eminent Construction Limited Toronto Transit Commission Address 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5775 Yonge Street 5760 Yonge Street 5795 Yonge Street 39 Manstor Road 5714 Yonge Street 5714 Yonge Street 5700 Yonge Street 1 Duplex Avenue 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 & 5700 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 31 Finch Avenue 31 Finch Avenue 5588 Yonge Street 5588 Yonge Street 5588 Yonge Street 431 Kenneth Ave 5453 Yonge Street 5453 Yonge Street 18 Kemptford Boulevard 18 Kemptford Boulevard 18 Kemptford Boulevard 18 Kemptford Boulevard 5435 Yonge Street 5435 Yonge Street 5435 Yonge Street 5435 Yonge Street 5435 Yonge Street 5435 Yonge Street 5435 Yonge Street 5418 Yonge Street 5385 Yonge Street 5385 Yonge Street City North York North York North York North York Toronto Toronto Toronto Toronto Toronto Toronto North York Toronto North York North York North York Toronto North York North York North York North York North York North York Toronto North York North York North York North York North York North York North York Toronto Willowdale North York Willowdale North York North York North York North York North York Willowdale North York Toronto Rexdale North York North York Rexdale Rexdale Toronto North York Toronto Toronto Notes: GEN - Registered Waste Generator 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 11 of 18 TABLE 4 SUMMARY OF REGISTERED WASTE GENERATORS CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID Company Name Address City Wastes generated may include pathological wastes, petroleum distillates, waste oils and lubricants, aromatic solvents, aliphatic solvents, photoprocessing wastes, akaline wastes, and oil skimmings and sludges. 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 12 of 18 TABLE 5 SUMMARY OF RECORDS OF SITE CONDITION CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID RSC-1 RSC-2 RSC-3 RSC-4 RSC-5 RSC-6 Company Name Meridian Residences Inc. Unknown 2015174 Ontario Inc. 1228131 Ontario Limited 1228131 Ontario Limited Eminent Construction Limited Address 35 Hendon Avenue 5575 Yonge Street 5566 Yonge Street 38 Byng Avenue 32 Byng Avenue 5427 Yonge Street City Toronto Toronto Toronto North York North York Toronto RSC Registration Number 31108 Unknown 2305 9103 9102 32704 Action Phase I ESA completed Unknown Phase I and II ESA completed Phase I ESA completed Phase I ESA completed Phase I and II ESA completed Results No contamination identified Unknown 10 m3 of soil removed No contamination identified No contamination identified No contamination identified Notes: RSC - Record of Site Condition m3 - cubic metres 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 1 of 1 TABLE 6 SUMMARY OF PESTICIDE REGISTER CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID PES-1 PES-2 PES-3 PES-4 PES-5 PES-6 PES-7 PES-8 PES-9 PES-10 PES-11 PES-12 PES-13 PES-14 PES-15 PES-16 PES-17 PES-18 PES-19 PES-20 PES-21 PES-22 PES-23 PES-24 PES-25 PES-26 PES-27 PES-28 PES-29 PES-30 PES-31 PES-32 PES-33 PES-34 PES-35 PES-36 PES-37 PES-38 PES-39 PES-40 PES-41 Company Name Shoppers Drugmart Duralawn Inc. Walters Landscape Contractors Ltd. Walters Landscape Contractors Ltd. Shoppers Drugmart Shoppers Drugmart Multitynes Ltd. Miyako Landscaping Ltd. J and B's Weed Control All Pest Control Services All Pest Control Services Beaver Lumber Hy and Zels Alex Landscape and Gardening Greenfield Lawncare and Landscaping Inc. Greenfield Lawncare and Landscaping Inc. Queripel and Son Limited Queripel and Son Limited Zellers Shoppers Drugmart Canadian Tire Canadian Tire LOH Merchandising Woolco Loblaws Loblaws Loblaws Smith and Son Hardware De Boer John Landscaping De Boer John Landscaping Newtonbrook Home Hardware Noble Tree Service Ltd. Noble Tree Service Ltd. Noble Tree Service Ltd. MJM Weed Control MJM Weed Control Ontario Hydro Ash Faltaous Pharmacy Loblaws 863850 Ontario Limited 863850 Ontario Limited Address 8865 Yonge Street 19 Ruggles Avenue 10 Ruggles Avenue 10 Ruggles Avenue 10 Royal Orchard Boulevard 10 Royal Orchard Boulevard 44 Elgin Street 14 Arnold Avenue 41 Arnold Avenue 30 Clark Avenue 30 Clark Avenue 7171 Yonge Street 7171 Yonge Street 34 Creastwood Road 57 Steeles Avenue 57 Steeles Avenue 82 Nipigon Avenue 82 Nipigon Avenue 6600 Yonge Street 6428 Yonge Street 6310 Yonge Street 6310 Yonge Street 6310 Yonge Street 6220 Yonge Street 6220 Yonge Street 6220 Yonge Street 6220 Yonge Street 6183 Yonge Street 24 Moore Park Avenue 24 Moore Park Avenue 5825 Yonge Street 2 Deering Crescent 2 Deering Crescent 2 Deering Crescent 40 Bowerbank Drive 40 Bowerbank Drive 5775 Yonge Street 5576 Yonge Street 5566 Yonge Street 5566 Yonge Street 5566 Yonge Street City Richmond Hill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Toronto Toronto Willowdale Toronto Willowdale North York Willowdale Willowdale Willowdale Willowdale Toronto Toronto Toronto Willowdale Willowdale Willowdale North York Toronto Willowdale Willowdale Willowdale Willowdale North York Toronto Toronto North York North York Operator Type Limited vendor Unknown Operator Operator Limited vendor Limited vendor General vendor Operator Operator Unknown Operator Vendor Limited vendor Operator Operator Operator Operator Operator Limited vendor Limited vendor Vendor Limited vendor Limited vendor Vendor Limited vendor Limited vendor Limited vendor Vendor Unknown Operator Limited vendor Operator Unknown Operator Unknown Operator Operator Limited vendor Vendor Limited vendor Vendor Notes: PES - pestide register 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 14 of 18 TABLE 7 SUMMARY OF PCB STORAGE SITES CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID NPCB-1 NPCB-2 NPCB-3 OPCB-1 Company Name Deep Foundations Contractors Inc. Ontario Hydro - North York Bell Canada Deep Foundations Contractors Inc. Address 26 Ruggles Avenue 5760 Yonge Street 31 Finch Avenue 26 Ruggles Avenue City Markham North York Willowdale Markham Description Unknown quantity of high-level PCBs (>10,000 ppm) stored for disposal. Unknown Unknown 400 kg of high-level PCBs (>1000 ppm); two drums of ballasts with high-level PCBs (>1000 ppm). Unknown OPCB-2 Ontario Hydro - North York 5760 Yonge Street North York OPCB-3 Ontario Hydro - North York 5760 Yonge Street North York 56 capacitors with high-level PCBs (>1000 ppm); 18 drums of other material with highlevel PCBs (>1000 ppm); 2700 kg of drums of other material with high-level PCBs (>1000 ppm). OPCB-4 OPCB-5 Ontario Hydro - North York Ontario Hydro - North York 5760 Yonge Street 5760 Yonge Street North York North York Unknown 56 capacitors with high-level PCBs (>1000 ppm); 18 drums of other material with highlevel PCBs (>1000 ppm); 2700 kg of drums of other material with high-level PCBs (>1000 ppm). Notes: NPCB - National Polychorinated Biphenyl Inventory OPCB - Ontario Polychorinated Biphenyl Inventory kg - kilograms > - greater than ppm - parts per million 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 15 of 18 TABLE 7 SUMMARY OF PCB STORAGE SITES CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 1 of 1 TABLE 8 SUMMARY OF NATIONAL POLLUTANT RELEASE INVENTORY CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID NPRI-1 NPRI-2 NPRI-3 NPRI-4 NPRI-5 Company Name Normac Kitchens Limited Normac Kitchens Limited Normac Kitchens Limited Normac Kitchens Limited Normac Kitchens Limited Address 59 Glen Cameron Road 59 Glen Cameron Road 59 Glen Cameron Road 59 Glen Cameron Road 59 Glen Cameron Road City Thornhill Thornhill Thornhill Thornhill Thornhill Description 33 tonnes of VOCs released in 2002. 64 tonnes of various chemical substances released in 2005. 45 tonnes of various chemical substances released in 2006. 32 tonnes of various chemical substances released in 2004. 33 tonnes of VOCs released in 2003. Notes: NPRI - National Pollutant Release Inventory 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 17 of 18 TABLE 9 SUMMARY OF MANUFACTURING FACILITIES CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID SCT-1 SCT-2 SCT-3 SCT-4 SCT-5 SCT-6 SCT-7 SCT-8 SCT-9 SCT-10 SCT-11 SCT-12 SCT-13 SCT-14 SCT-15 SCT-16 SCT-17 SCT-18 SCT-19 SCT-20 SCT-21 SCT-22 SCT-23 SCT-24 SCT-25 SCT-26 SCT-27 SCT-28 SCT-29 SCT-30 SCT-31 SCT-32 SCT-33 SCT-34 SCT-35 SCT-36 SCT-37 SCT-38 SCT-39 SCT-40 SCT-41 SCT-42 SCT-43 SCT-44 SCT-45 SCT-46 SCT-47 SCT-48 SCT-49 SCT-50 SCT-51 SCT-52 SCT-53 SCT-54 SCT-55 SCT-56 SCT-57 Company Name EmbroidMe Wright Environmental Management Inc. Mid-Ontario Truck Centre D and S Equipment Ltd. Cooper Machine and Tool Inc. Metro Stone and Pavement Co. Woody Custom Lettering Limited Beaver Valley Stone Ltd. Neale and Associates Ltd. Stellar Optics Research International Corporation Cottage Games Canada Baron Von Egon Gems and Gold Sign*A*Rama Allergy Canada Ltd. Yorkminster Publishing Environmental Enterprises Inc. SOWDON Distributing Co. Ltd. Chris & Tal's Better Foods The Jackie Stone Group Normac Kitchens Limited Normac Kitchens Limited Normac Kitchens Limited Art Venetian Blind Limited Northtown Technical Art Venetian Blind Limited Storm Island Furniture Ltd. Preci Machines & Tools Collins Metal Products Potter Electric Signal Kidder Manufacturing Ltd. Kidder Manufacturing Ltd. Kidder Technologies Inc. Tara Embroidery Ltd. Bow Art Canada Inc. Kidder Technologies Inc. Industrial Mechanical Specialties Ltd. Casemaker Incorporated Industrial Mechanical Glowing Panes Glassworks Ltd. Glowing Panes Glassworks Ltd. Top Quality Interiors Ltd. Original Bavarian Pretzel Inc. Original Bavarian Pretzel Inc. Logart Inc. Northwest Auto Parts Sam Edwards Auto Parts Ltd. Gateaux-Gil Inc. Gateaux-Gil Inc. Eli Graphics and Printing Jewellery Design By Steven Segal Jewellery Design By Steven Segal Nino Daversa Bakery Ltd. Nino Daversa Bakery Ltd. Nino Daversa Bakery Ltd. Nino Daversa Bakery Ltd. Print Three Print Three Address 8950 Yonge Street 9050 Yonge Street 9076 Yonge Street 9137 Yonge Street 25 Ruggles Avenue 19 Ruggles Avenue 17 Ruggles Avenue 25 Langstaff Road 14 Vistaview Boulevard 78 Normark Drive 26 Uplands Avenue 8108 Yonge Street 8100 Yonge Street 10 Royal Orchard Boulevard 7811 Yonge Street 7751 Yonge Street 151 Brooke Street 53 Thornridge Drive 90 Browntstone Circle 59 Glen Cameron Road 59 Glen Cameron Road 59 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 55 Glen Cameron Road 39 Glen Cameron Road 39 Glen Cameron Road 39 Glen Cameron Road 39 Glen Cameron Road 39 Glen Cameron Road 39 Glen Cameron Road 33 Glen Cameron Road 33 Glen Cameron Road 33 Glen Cameron Road 11 Glen Cameron Road 11 Glen Cameron Road 11 Glen Cameron Road 60 Doncaster Avenue 60 Doncaster Avenue 73 Doncaster Avenue 50 Doncaster Avenue 50 Doncaster Avenue 50 Doncaster Avenue 50 Doncaster Avenue 7089 Yonge Street 1 Steeles Avenue 1 Steeles Avenue 72 Steeles Avenue 72 Steeles Avenue 72 Steeles Avenue 72 Steeles Avenue 6420 Yonge Street 6420 Yonge Street City Richmond Hill Richmond Hill Richmond Hill Richmond Hill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Thornhill Markham Thornhill North York North York Thornhill Thornhill Thornhill Thornhill Toronto Toronto 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009 Page 18 of 18 TABLE 9 SUMMARY OF MANUFACTURING FACILITIES CONTAMINATION OVERVIEW STUDY YONGE STREET SUBWAY EXTENSION Map ID SCT-58 SCT-59 SCT-60 SCT-61 SCT-62 SCT-63 SCT-64 SCT-65 SCT-66 SCT-67 SCT-68 SCT-69 SCT-70 SCT-71 SCT-72 SCT-73 SCT-74 SCT-75 SCT-76 SCT-77 SCT-78 SCT-79 SCT-80 SCT-81 SCT-82 SCT-83 SCT-84 SCT-85 SCT-86 SCT-87 SCT-88 SCT-89 SCT-90 SCT-91 SCT-92 SCT-93 SCT-94 SCT-95 SCT-96 SCT-97 SCT-98 SCT-99 SCT-100 SCT-101 SCT-102 SCT-103 SCT-104 SCT-105 SCT-106 SCT-107 SCT-108 Company Name Act II International Inc. Act II International Inc. Minuteman Press Inc. E M E Electronics Limited E M E Electronics Limited York Town Decorating Advent Printing Co. Annick Press Ltd. Annick Press Ltd. Colordox Printing Co. Kwik Copy Printing Emerston Instruments Inc. The Successful Investor Inc. Ontario Industrial Magazine Fuller Technologies Ltd. Shirriff Packaging Inc. Speedy Printing Centres Korean-Canadian Literary Forum Dyad Infosys Ltd. Icard Systems Inc. Bay Networks Canada Advanced Computing Edge Ltd. K and H Central Laboratories Clorox Company of Canada Ltd. Print Three H.J. Heinz Company of Canada Ltd. Clorox Company of Canada Ltd. H.J. Heinz Company of Canada Ltd. Cognos Inc. Adesign Advertising & Production Inc Adesign Advertising & Production Inc. Xerox Canada Ltd. D.D. Synergy Business Process Intergration Canada Inc. Bowe Bell + Howell Bowe Bell & Howell Xerox Canada Ltd. Bowe Bell & Howell Diamond Dental Laboratory Ltd. Sunrise Printing Corp. Korean Entertainment Weekly Danforth Fur & Leatherwear Ltd. Danforth Fur & Leatherwear Ltd. Wastex Disposal and Recycling Balex Economy Balers & Compactors Shredmaster Company of Canada Balex Economy Wastex Disposal and Recycling Balex Economy Security Engineered Machinery Shredmaster Company of Canada STA Inc. Address 6267 Yonge Street 6267 Yonge Street 6186 Yonge Street 43 Newton Drive 43 Newton Drive 6120 Yonge Street 6066 Yonge Street 15 Patricia Avenue 15 Patricia Avenue 6037 Yonge Street 6035 Yonge Street 6021 Yonge Street 6021 Yonge Street 6021 Yonge Street 6021 Yonge Street 6021 Yonge Street 5847 Yonge Street 5845 Yonge Street 5803 Yonge Street 5799 Yonge Street 5775 Yonge Street 5799 Yonge Street 5643 Yonge Street 5700 Yonge Street 5700 Yonge Street 5700 Yonge Street 5700 Yonge Street 5700 Yonge Street 5700 Yonge Street 29 Pemberton Avenue 29 Pemberton Avenue 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 5650 Yonge Street 18 Finch Avenue 5580 Yonge Street 48 Finch Avenue 5465 Yonge Street 5465 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 5460 Yonge Street 52 Lorraine Drive City North York North York North York North York North York North York North York Willowdale Toronto North York North York North York North York North York Toronto North York North York North York North York Willowdale North York North York North York Toronto North York North York Toronto North York North York North York North York North York Toronto Toronto Toronto Toronto Toronto North York North York North York North York North York Toronto North York North York North York North York Willowdale North York Willowdale Toronto Notes: SCT - Scott's Manufacturing Directory 10-6959 W:\6k\6959 Yonge Subway Extension Functional Planning Study\6959.800 Transit\6959.804 Reports\Contamination\Jan 26-09 FINAL Report\6959-Rpt-Tbls-January 2009.xls January 2009