INSTALLATION INSTRUCTIONS For Incandescent Decorative Stemlight Pendant Series: CGI8 and CGI12 INSTALLATION PROCEDURES

advertisement
INSTALLATION INSTRUCTIONS
For Incandescent Decorative Stemlight Pendant Series:
CGI8 and CGI12
INSTALLATION PROCEDURES
FC MOUNT: Flexible Cable Mono-Point, Damp Location Listed
RS MOUNT: Rigid Stem Mono-Point, Damp Location Listed
Ensure 4" Round or 4" Square (with a Round-to-Square Junction Box Cover Plate)
Junction Box is properly mounted to the ceiling structure.
The center-to-center mounting holes on the 4" Round Junction Box are 3-1/2";
the Round-to-Square Junction Box Cover are 2-3/4". Both use 8-32 x 1/2"
screws. Loosen the (2) Philips screws that hold the mounting strap to the top
round wiring compartment. Attach the mounting strap to the junction box or
junction box cover.
Follow fixture assembly instructions.
FIXTURE ASSEMBLY INSTRUCTIONS
The Bicycle Cable Connector with has (1) 2mm recessed Allen Screw for locking
into the nipple plus (2) 2mm recessed Allen Screws for locking into the bicycle
cable. (1) 2mm Allen Wrench is supplied with each fixture.
The shade/hood assembly comes with 132" of socket lead wiring (Blue, Red,
Green) in a silicone sleeve.
Bicycle Cable: Determine length of Bicycle Cable required. If cutting is required,
loosen bicycle cable from connector. Slide the bicycle cable off
the wiring. Remove wire grommet. Cut bicycle cable with a
hacksaw using a fine tooth (32T) blade, BX Armor cable cutter or
high speed metal cutting blade. Remove any sharp edges.
Re-insert internal wire grommet. Slide bicycle cable over the
wiring (socket wiring: Red, Blue; plus Green ground). Note: The
Bicycle Cable will only accept the wires less the silicone sleeve.
Re-insert the Bicycle Cable Connector. Tighten all the Allen
screws along the way to the maximum.
Nipple
Mono-Point Canopy
Allen Screw
Locks Onto
Nipple
Allen Screws
Lock Onto
Bicycle Cable
Bicycle Cable
Connector
Swivel Stem
Attachment
Rigid Stem: Determine the length of the stem with internal coupling required for
your job. A swivel stem attachment is included for sloped ceiling
applications, 35º adjustment. Assemble the stems onto the
shade/hood assembly one at a time, carefully feeding the wiring
through each section. After all the stems are attached completely,
insert the wiring into the bottom of the canopy. Screw the stem(s)
into the nipple. Tighten all the Allen screws along the way to the
maximum.
WIRING INSTRUCTIONS
Attach the bicycle cable connector to the nipple of the track adapter plate. Red
Socket Lead to the center of the socket or bottom solder contact. Blue socket
lead to the brass threading of the lamp. Attach bicycle cable connector to the
bicycle cable, attach bicycle cable connector to the nipple on the canopy.
Tighten all of the 2mm Allen Screws along the way to the maximum. Insert
socket wiring through the nipple. Wiring is (Blue-to-White, Red-to-Black, Green-toGreen). Insert the wiring into the nipple. Using the (2) Pan Head Screws, attach
the fixture assembly/bottom plate to the track adapter or ceiling canopy.
Continued on page 2
Top of Canopy
1
All specifications subject to change without notice.
1-847-559-5500
www.con-techlighting.com
This document can be recycled.
IDECOSTMLT INST
INSTALLATION INSTRUCTIONS
For Incandescent Decorative Stemlight Pendant Series:
CGI8 and CGI12
SHADE ASSEMBLY INSTRUCTIONS
Loosen the (4) Allen Screws from the arms of the cast frame. Insert the correct
wattage lamp(s) into the socket(s). Rest the decorative shade into the bottom cast
ring, then reattach the (4) Allen Screws into the cast arms. Unpack the floating
glass and attach to the bottom of the cast frame and attach to the bottom of the
cast frame using the (4) floating ring attachment mechanisms: screw in the double
threaded bolt with the center ribbed collar, then attach the glass. To lock the glass
in place, screw on the knurled nut.
12" Decorative Stemlight
Allen Screw
Floating Glass
8" Decorative Stemlight
Allen Screw
Floating Glass
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Wear rubber soled shoes should and work on a sturdy wooden or non-conductive ladder.
• Product must be mounted in locations and at heights in a manner consistent with its intended use, and in compliance with National Electrical
Code and local building codes. For indoor use only.
• Do not exceed the nominal supply voltage or amperage ratings.
• Make sure all screws are properly tightened.
• Do not install any lampholder closer than 6" from any curtain or similar combustible material.
• Use only fixtures and fittings intended for use with Con-Tech Decorative Stemlight Pendant systems.
• Installing contrary to instructions may cause unsafe conditions.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation.
• Warning: Risk of burns. Lamps are extremely hot when lit. Allow lamps to cool down in temperature before handling.
• To avoid hazards to children, account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at Con-Tech Lighting with any installation questions: 847.559.5500.
2
All specifications subject to change without notice.
1-847-559-5500
www.con-techlighting.com
This document can be recycled.
IDECOSTMLT INST
Download