NJDCA ELECTRONIC SUBMITTAL STAMP:
ALTERATION
A.4
2.9
F
E
G
H
I
J
K
M
N
Q Q.1
Q.2 Q.3
C.
D.
SF12
SF12
E.
22
F.
2.1
SF11
G.
UPPER TOWER PLAN
B
C
D
I.
J.
K.
19
WOMEN'S
LAV.
134
21
L.
20
M.
19
N.
O.
P.
MEN'S LAV.
143
Q.
18
S
I
A
R EG
1/8" = 1'-0"
TE
C N
RK
N
2
E
NEW
OF O J
SEY
ER OR
H.
SEALED:
No.
16419
CT
B.
ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE
START OF CONSTRUCTION.
ALL DIMENSIONS GIVEN ARE TO THE FACE OF CONCRETE
MASONRY UNIT (CMU) OR TO FACE OF GYPSUM
WALLBOARD/METAL STUD CONSTRUCTION, UNLESS NOTED
OTHERWISE.
FOR PARTITION ASSEMBLY TYPES REFER TO DRAWING A001.
ALL DOORS ARE TO BE LOCATED 4" FROM WALL TO DOOR
JAMB OPENING UNLESS OTHERWISE NOTED.
CONTRACTOR IS RESPONSIBLE FOR BRACING/STABILIZING
EXISTING WALLS AND STRUCTURE DURING CONSTRUCTION
(SPECIFICALLY AT NEW DOOR LOCATIONS), ATTACH
FRAME WITH "TAPCON" FASTENERS.
PATCH ALL OPENINGS IN REMAINING WALLS WHERE
MECHANICAL OR PLUMBING EQUIPMENT HAS BEEN
REMOVED. INFILL WITH LIKE MATERIAL. BLEND & SMOOTH
TO MATCH EXISTING ADJACENT CONDITIONS.
PATCH ALL HOLES IN MASONRY WALLS AND GYPSUM
WALL BOARD RESULTING FROM DEMOLITION AND
REMOVAL. INFILL WITH LIKE MATERIAL. BLEND & SMOOTH
TO MATCH EXISTING ADJACENT CONDITIONS.
FIRE STOPPING MATERIAL SHALL BE INSTALLED AROUND ALL
NEW AND EXISTING PIPES, DUCTS, CONDUITS OR OTHER
PENETRATIONS IN FIRE PARTITION, FIRE BARRIER AND FIRE
WALLS, TYPICAL. FIRE STOPPING
MATERIAL SHALL
BE INSTALLED AT JUNCTION OF NEW WALLS, FLOOR DECK
AND/OR ROOF DECK. REFER TO DRAWING G100 FOR FIRE
RESISTANCE RATING OF ALL WALLS.
REFER TO ROOM FINISH PLAN FOR ALL FINISHES AND
LOCATIONS.
ALL GYPSUM WALLBOARD INSTALLED OVER NEW OR
EXISTING WALLS SHALL EXTEND 6" ABOVE FINISH CEILING.
REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING
DRAWINGS FOR COORDINATION OF ALL EQUIPMENT.
COORDINATE ALL ELECTRICAL ITEMS WITH CASEWORK
DRAWINGS FOR ALL ELECTRICAL COORDINATION CUT
OUTS.
VERIFY LOCATION OF NEW KITCHEN EQUIPMENT FOR
PLACEMENT AND UTILITY CONNECTIONS. REFER TO
MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS
FOR INFORMATION.
REFER TO A150'S FOR PLAN DETAILS.
PATCH FLOORS WHERE WALLS HAVE BEEN DEMOLISHED TO
MATCH EXISTING SLAB ELEVATION AND PREP FOR NEW
FLOOR FINISH. REFER TO FLOORING DRAWINGS FOR NEW
FLOOR FINISHES.
PROVIDE BLOCKING IN WALLS TO INSTALL WALL MOUNTED
EQUIPMENT (CASEWORK & ACCESSORIES).
REFER TO DRAWING A001 FOR DOOR AND WINDOW
INFORMATION.
TE
A.
SF11
MA
6
A-150
GENERAL NOTES
S TAT
A
R E D A RC H
I
CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR
UNAUTHORIZED USE OF THIS DOCUMENT.
DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS.
ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD.
ARCHITECT:
1656 Massachusetts Ave. | Lexington, MA 02420
Tel: 781-652-0114 | connorarchitecture.com
ENGINEER:
17
EXISTING
VESTIBULE
41
1
A5
108
16
17
49 Court Street | P.O. Box 1980 | Binghamton, NY 13902
Tel: 607-723-9421 | mjinc.com
107
15
KEYED NOTES
SF8
15
RETAIL
SERVERY
4
14
1
10.3
VESTIBULE
ADDITION
42
RESIDENTIAL
SERVERY
2
13
A1. NEW WINDOW INFILL IN EXISTING CIRCULAR OPENING.
REFER TO A-002 FOR MORE INFORMATION.
A2. FLOOR INFILL AT EXISTING STAIR, REFER TO STRUCTURAL
DRAWINGS
A3. NEW CONCRETE STAIR, REFER TO I-103 FOR FINISH
A4. PAINTED STEEL EXTERIOR COLUMN. REFER TO A-302,
STRUCTURAL DWGS, & LANDSCAPING DWGS.
A5. DOOR TO HAVE HANDICAPPED ACCESS OPERATOR. REFER
TO DOOR SCHEDULE & SPECIFICATIONS.
REVISIONS
1
4/13/2016
DRAWN BY:
JNC
CHECKED BY:
AGK/JNC
SF7
SF7B
A4
10.8
A5
1
A-302
SF1
UPPER
RESIDENTIAL
DINING
1
AREA OF ALTERATIONS
EXISTING TO REMAIN
101
2
A-150
NEW
VESTIBULE
100
40
10
7
A-150
SF7A
8
9
4
4
SF13
105
A4
1
A-150
A-301
1
A-301
A4
A-302
RETAIL
DINING
34
6
A3
A4
A-200
A5
2
3
A-150
7
LOWER
RESIDENTIAL
DINING
3
SF6
6
All temporary partitions are shown in
red and must be framed with metal or
wood and constructed of plywood
from floor to ceiling when exterior
work is taking place. Walls must
have doors with panic hardware and
are to be used for emergency egress.
102
SF2
5
5
2
A-201
A-200
111
A2
7.1
10.2 2
103
4
A4
8
A-300
2.9
3
A-150
3
A-150
SIM
SIM
LOWER
LOUNGE
32
A1
3
A3
A4
L
W1
5
1
A-001
W2
2.1
A-301
1
3
4
A-150
A-301
1.9
W3
W4
2
W2
1
SF3
9
A-300
A
A-301
A.4
B
1
10
A-201
A-300
B.7
104
SF4
C
M
1
SF5
E
F
G
H
I
J
K
N
O
Q Q.1
Q.2 Q.3
5
A-200
N
ISSUED:
03.24.2016
DESCRIPTION:
1
FLOOR PLAN - EXTERIOR - NOTED
BID DOCUMENTS
1/8" = 1'-0"
SHEET:
A-100
PHASE 2: ALTERATIONS & ADDITIONS
1
1
A-200
10.9
RCNJ No. 2014-37-01C
3
RAMAPO COLLEGE
OF NEW JERSEY
11
SCOTT STUDENT CENTER
RESIDENTIAL DINING
5
A-150
SF7C
505 RAMAPO VALLEY RD.
MAHWAH, NJ 07430
11
A-200
FLOOR PLAN - NOTED
12