4/11/2016 3:56:28 PM NJDCA ELECTRONIC SUBMITTAL STAMP: ALTERATION A.4 2.9 F E G H I J K M N Q Q.1 Q.2 Q.3 C. D. SF12 SF12 E. 22 F. 2.1 SF11 G. UPPER TOWER PLAN B C D I. J. K. 19 WOMEN'S LAV. 134 21 L. 20 M. 19 N. O. P. MEN'S LAV. 143 Q. 18 S I A R EG 1/8" = 1'-0" TE C N RK N 2 E NEW OF O J SEY ER OR H. SEALED: No. 16419 CT B. ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE START OF CONSTRUCTION. ALL DIMENSIONS GIVEN ARE TO THE FACE OF CONCRETE MASONRY UNIT (CMU) OR TO FACE OF GYPSUM WALLBOARD/METAL STUD CONSTRUCTION, UNLESS NOTED OTHERWISE. FOR PARTITION ASSEMBLY TYPES REFER TO DRAWING A001. ALL DOORS ARE TO BE LOCATED 4" FROM WALL TO DOOR JAMB OPENING UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR BRACING/STABILIZING EXISTING WALLS AND STRUCTURE DURING CONSTRUCTION (SPECIFICALLY AT NEW DOOR LOCATIONS), ATTACH FRAME WITH "TAPCON" FASTENERS. PATCH ALL OPENINGS IN REMAINING WALLS WHERE MECHANICAL OR PLUMBING EQUIPMENT HAS BEEN REMOVED. INFILL WITH LIKE MATERIAL. BLEND & SMOOTH TO MATCH EXISTING ADJACENT CONDITIONS. PATCH ALL HOLES IN MASONRY WALLS AND GYPSUM WALL BOARD RESULTING FROM DEMOLITION AND REMOVAL. INFILL WITH LIKE MATERIAL. BLEND & SMOOTH TO MATCH EXISTING ADJACENT CONDITIONS. FIRE STOPPING MATERIAL SHALL BE INSTALLED AROUND ALL NEW AND EXISTING PIPES, DUCTS, CONDUITS OR OTHER PENETRATIONS IN FIRE PARTITION, FIRE BARRIER AND FIRE WALLS, TYPICAL. FIRE STOPPING MATERIAL SHALL BE INSTALLED AT JUNCTION OF NEW WALLS, FLOOR DECK AND/OR ROOF DECK. REFER TO DRAWING G100 FOR FIRE RESISTANCE RATING OF ALL WALLS. REFER TO ROOM FINISH PLAN FOR ALL FINISHES AND LOCATIONS. ALL GYPSUM WALLBOARD INSTALLED OVER NEW OR EXISTING WALLS SHALL EXTEND 6" ABOVE FINISH CEILING. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR COORDINATION OF ALL EQUIPMENT. COORDINATE ALL ELECTRICAL ITEMS WITH CASEWORK DRAWINGS FOR ALL ELECTRICAL COORDINATION CUT OUTS. VERIFY LOCATION OF NEW KITCHEN EQUIPMENT FOR PLACEMENT AND UTILITY CONNECTIONS. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR INFORMATION. REFER TO A150'S FOR PLAN DETAILS. PATCH FLOORS WHERE WALLS HAVE BEEN DEMOLISHED TO MATCH EXISTING SLAB ELEVATION AND PREP FOR NEW FLOOR FINISH. REFER TO FLOORING DRAWINGS FOR NEW FLOOR FINISHES. PROVIDE BLOCKING IN WALLS TO INSTALL WALL MOUNTED EQUIPMENT (CASEWORK & ACCESSORIES). REFER TO DRAWING A001 FOR DOOR AND WINDOW INFORMATION. TE A. SF11 MA 6 A-150 GENERAL NOTES S TAT A R E D A RC H I CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. ARCHITECT: 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com ENGINEER: 17 EXISTING VESTIBULE 41 1 A5 108 16 17 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com 107 15 KEYED NOTES SF8 15 RETAIL SERVERY 4 14 1 10.3 VESTIBULE ADDITION 42 RESIDENTIAL SERVERY 2 13 A1. NEW WINDOW INFILL IN EXISTING CIRCULAR OPENING. REFER TO A-002 FOR MORE INFORMATION. A2. FLOOR INFILL AT EXISTING STAIR, REFER TO STRUCTURAL DRAWINGS A3. NEW CONCRETE STAIR, REFER TO I-103 FOR FINISH A4. PAINTED STEEL EXTERIOR COLUMN. REFER TO A-302, STRUCTURAL DWGS, & LANDSCAPING DWGS. A5. DOOR TO HAVE HANDICAPPED ACCESS OPERATOR. REFER TO DOOR SCHEDULE & SPECIFICATIONS. REVISIONS 1 4/13/2016 DRAWN BY: JNC CHECKED BY: AGK/JNC SF7 SF7B A4 10.8 A5 1 A-302 SF1 UPPER RESIDENTIAL DINING 1 AREA OF ALTERATIONS EXISTING TO REMAIN 101 2 A-150 NEW VESTIBULE 100 40 10 7 A-150 SF7A 8 9 4 4 SF13 105 A4 1 A-150 A-301 1 A-301 A4 A-302 RETAIL DINING 34 6 A3 A4 A-200 A5 2 3 A-150 7 LOWER RESIDENTIAL DINING 3 SF6 6 All temporary partitions are shown in red and must be framed with metal or wood and constructed of plywood from floor to ceiling when exterior work is taking place. Walls must have doors with panic hardware and are to be used for emergency egress. 102 SF2 5 5 2 A-201 A-200 111 A2 7.1 10.2 2 103 4 A4 8 A-300 2.9 3 A-150 3 A-150 SIM SIM LOWER LOUNGE 32 A1 3 A3 A4 L W1 5 1 A-001 W2 2.1 A-301 1 3 4 A-150 A-301 1.9 W3 W4 2 W2 1 SF3 9 A-300 A A-301 A.4 B 1 10 A-201 A-300 B.7 104 SF4 C M 1 SF5 E F G H I J K N O Q Q.1 Q.2 Q.3 5 A-200 N ISSUED: 03.24.2016 DESCRIPTION: 1 FLOOR PLAN - EXTERIOR - NOTED BID DOCUMENTS 1/8" = 1'-0" SHEET: A-100 PHASE 2: ALTERATIONS & ADDITIONS 1 1 A-200 10.9 RCNJ No. 2014-37-01C 3 RAMAPO COLLEGE OF NEW JERSEY 11 SCOTT STUDENT CENTER RESIDENTIAL DINING 5 A-150 SF7C 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 11 A-200 FLOOR PLAN - NOTED 12