3/23/2016 3:20:15 PM NJDCA ELECTRONIC SUBMITTAL STAMP: SEALED: HVAC LEGEND PIPING SYMBOL DESCRIPTION PIPING SYMBOL CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DESCRIPTION DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. ARCHITECT: PIPING RISE AD ACCESS DOOR PIPING DROP AFF ABOVE FINISH FLOOR BTUH BRITISH THERMAL UNITS PER HOUR BOTTOM PIPE CONNECTION DIA, ø DIAMETER DN DOWN (E) EXISTING EWT ENTERING WATER TEMPERATURE (°F) °F DEGREES FAHRENHEIT GPM GALLONS PER MINUTE HWR HOT WATER RETURN HWS HOT WATER SUPPLY LWT LEAVING WATER TEMPERATURE (°F) NTS NOT TO SCALE TOP PIPE CONNECTION STRAINER BALANCE VALVE PIPING REDUCER - CONCENTRIC PIPE CAP 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com ENGINEER: 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com REVISIONS RUNTAL RADIATION SCHEDULE RUNTAL RADIATION WITH ENCLOSURE T UNIT NO. THERMOSTAT 2-WAY CONTROL VALVE MV MANUAL AIR VENT DIMENSIONS CAPACITY LOCATION DESIGN BASIS E.W.T. L.W.T. (degrees F) (degrees F) BTUH PER LINEAR FT LENGTH HEIGHT FTR-1 SEE PLANS 180 150 950 SEE PLANS 11.5" RUNTAL - RF-5 FTR-2 SEE PLANS 180 150 800 SEE PLANS 11.5" RUNTAL - UFLT-4 FTR-3 SEE PLANS 180 150 500 SEE PLANS 6" RUNTAL - UFLT-2 NOTES DRAWN BY: CJZ CHECKED BY: PP BALL VALVE ALL VALVING & CONTROLS TO BE IN CEILING SPACE BALL VALVE STRAINER HWR 2-WAY CONTROL VALVE HWS M 1 RUNTAL RADIATION DETAIL SCALE - NONE RUNTAL RADIATION CONTROL A. RUN CONDITIONS - CONTINUOUS: THE UNIT SHALL RUN CONTINUOUSLY AND SHALL MAINTAIN A HEATINGB SETPOINT OF 70 DEGREE F (ADJ.). HEATING VALVE (24v CONTROL WIRE ) RUNTAL RADIATOR. CONTRACTOR RESPONSIBLE FOR PROPER HOT WATER SUPPLY & RETURN CONNECTION TYPES ZONE SENSOR T HOT WATER SUPPLY B. HEATING VALVE CONTROLLER SHALL MEASURE THE ZONE TEMPERATURE AND MODULATE THE HEATING COIL VALVE TO MAINTAIN ITS HEATING SETPOINT. ALL RUNTAL RADIATORS HOT WATER RETURN 2 RUNTAL RADIATION CONTROL SCALE - NONE ISSUED: 3.24.2016 DESCRIPTION: BID DOCUMENTS SHEET: M-000 18031.00 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 RAMAPO COLLEGE OF NEW JERSEY BALANCE VALVE SCHEDULES, DETAILS & CONTROLS AIR VENT RCNJ No.201437.01C ALTERATIONS BALL VALVE - OPEN 3/23/2016 3:23:21 PM NJDCA ELECTRONIC SUBMITTAL STAMP: HVAC LEGEND DIFFUSER & REGISTER SCHEDULE UNIT DUCT SYMBOL DESCRIPTION LINE TYPE SYMBOL DESCRIPTION DUCT UP - POSITIVE PRESSURE ABBREVIATION DEMOLITION EQUIPMENT DUCT UP - NEGATIVE PRESSURE EXISTING EQUIPMENT TO REMAIN DUCT DN - POSITIVE PRESSURE NEW EQUIPMENT DUCT DN - NEGATIVE PRESSURE SERVICE DESCRIPTION MAX CFM FACE NECK SIZE SIZE MAX. NC ARRANGEMENT MAX. S.P. BASIS (in. wc.) D-A SUPPLY 250 12x12 10" 12 0.3 CEILING TITUS SPECTRUM BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR D-B SUPPLY 300 18x8 - 15 0.07 DUCT MOUNTED TITUS SPIRAL S301FL DOUBLE DEFLECTION CFM CUBIC FEET PER MINUTE D-C SUPPLY 200 14x6 CUSTOM 12 0.03 WALL TITUS 300RS CUH CABINET UNIT HEATER D DIFFUSER D-D SUPPLY 250 12x12 - 12 0.3 CEILING TITUS SPECTRUM 1 DIA DIAMETER D-E SUPPLY 1000 36x12 - 15 0.3 WALL TITUS 300RS 1, 2 3 1 DUCT BALANCE OR VOLUME DAMPER RECTANGULAR DUCT WITH TURNING VANES RADIUS ELBOW (MIN. R/W = 1.5) EXHAUST REGISTER SUPPLY DIFFUSER NOTES DESIGN D-E SUPPLY 350 48x6 8" PLENUM 20 0.5 CEILING TITUS FLOW BAR FL15 1.5" SLOT JET R-A EXHAUST 450 24x24 - 10 0.03 CEILING TITUS 300RS DN DOWN DWG DRAWING (E) EXISTING EA EXHAUST AIR 1. NECK TO BE EXISTING BRANCH DUCT SIZE. EF EXHAUST FAN 2. D-E TO BE FACTORY PAINTED BLACK. HP HORSE POWER KW KILOWATTS MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPACITY MOP MAXIMUM OVER-CURRENT PROTECTION NTS NOT TO SCALE R REGISTER SEALED: 3. DIFFUSER TO COME WITH CORRESPONDING FACTORY PLENUM & FACE ADJUSTABLE VOLUME DAMPER. CONNECTION FOR GYPSUM BOARD. ELECTRIC CABINET UNIT HEATER SCHEDULE AIR FLOW UNIT NO. LOCATION CFM DIMENSIONS CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DESIGN BASIS ELECTRICAL DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. NOTES ARCHITECT: CUH-1 MAIN VESTIBULE LENGTH WIDTH HEIGHT CAPACITY (BTUH) 36 30 10 10,236 300 CAPACITY (KW) 3KW VOLTS/PHASE HP 208/1 1/4 TRANE - FCEB030 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com ENGINEER: FAN SCHEDULE UNIT NO. LOCATION PERFORMANCE AREA SERVED C.F.M. EF-1 ROOF EXISTING WOK HOOD 2400 ELECTRICAL TOTAL S.P. FAN SPEED RPM SONES 3.0 2655 27 VOLTS/PHASE TYPE DRIVE CONN. POINTS HP ROOF OPG. ROOF OPG. LENGTH WIDTH PHYSICAL PROPERTIES LENGTH" 460/3 5 1 UTILITY - KITCHEN EXHAUST BELT - - 40 DESIGN BASIS WIDTH" HEIGHT" WEIGHT LBS. 28 32 280 NOTES 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com GREENHECK-13-CSW-BI-21-10-I-50 1 REVISIONS DUCT MAIN DUCT MAIN V.D. INSULATED, FLEXIBLE DUCT V.D. MINIMUM 80" DISCHARGE HEIGHT EXHAUST FAN DISCHARGE EXTENSION BRANCH V.D. 48" MAX (TYP.) 1X DUCT DIA. OFFSET (MAX.) BIRD SCREEN AND RAIN COVER CAP DUCT END EXHAUST FAN MOTOR COVER ACCESS DOOR PANDUIT STRAP (TYP.) SHEET METAL "PLENUM" BOX (TYP.) SUPPLY AIR DIFFUSER (TYP.) PAINT INSIDE FLAT BLACK MIN. 6" HIGHER THAN BRANCH DUCT DEPTH MODIFY EXISTING EXHAUST FAN SUPPORTS AS REQUIRED FOR NEW EXHAUST FAN DUCT MAIN DAMPER/REGISTER 30 DEGREE ANGLE TOWARDS FLOOR, AVOID NEW ARCHITECTURAL CEILING CLOUD. CEILING EXISTING EXHAUST DUCT FROM KITCHEN HOOD FLEX CONNECTION ROOF LINE SUPPLY CEILING DIFFUSER 1 EXHAUST & SUPPLY REGISTER - WALL/CEILING SUPPLY - ROUND DUCT MOUNTED DIFFUSER 2 DIFFUSERS & REGISTERS DETAIL SCALE - NONE EXHAUST FAN DETAIL 3" = 1'-0" ELEC. COIL TEMPERATURE SENSOR IN RETURN AIR M FAN STATUS CT 13 FAN START/STOP LEGEND: 1 4 5 6 11 10 12 2 7 3 1 ACCESS DOOR OPENING 2 ALL THREAD RODS 3 INSULATION PINS - WELDED TO COVER 4 FIRST LAYER FIRE RATED DUCT WRAP 2" 5 SECOND LAYER FIRE RATED DUCT WRAP 2", 1" OVERLAP 6 THIRD LAYER FIRE RATED DUCT WRAP 2", 1" OVERLAP 7 SPEED CLIPS/WASHERS 8 CUT EDGES SEALED WITH ALUMINUM FOIL TAPE 9 WING NUTS CABINET UNIT HEATER CONTROL A. RUN CONDITIONS - CONTINUOUS: THE UNIT SHALL RUN CONTINUOUSLY AND SHALL MAINTAIN A HEATING SETPOINT OF 70 DEG. F (ADJ.). B. FAN: THE FAN SHALL RUN ANYTIME THE ZONE TEMPERATURE IS BELOW THE HEATING SETPOINT, UNLESS SHUTDOWN ON SAFETIES. 10 WASHERS C. THE HEATING SHALL BE ENABLED WHENEVER: 1. OUTSIDE AIR TEMPERATURE IS LESS THAN 60 DEG. F (ADJ.) 2. ZONE TEMPERATURE IS BELOW HEATING SETPOINT. 11 INSULATION PLATE D. THE CONTROLLER SHALL MONITOR THE FAN STATUS. 12 PRE-FABRICATED ACCESS DOOR 13 2 LAYERS FIRE RATED DUCT WRAP E. ALARMS SHALL BE PROVIDED AS FOLLOWS: 1. FAN FAILURE: COMMAND ON, BUT THE STATUS IS OFF. 2. FAN IN HAND: COMMAND OFF, BUT THE STATUS IS ON. 3. LOW ZONE TEMP.: ID THE ZONE TEMPERATURE IS LESS THAN THE HEATING SETPOINT BY A USER DEFINABLE AMOUNT OF TIME (ADJ.). 8 ISSUED: 3.24.2016 DESCRIPTION: 9 3 FIRE RATED DUCT ACCESS DOOR DETAIL SCALE - NONE BID DOCUMENTS 4 CABINET UNIT HEATER CONTROL SCALE - NONE 5 EXISTING EXHAUST FAN SHEET: SCALE - NONE M-001 18031.00 DUCT MAIN PP RCNJ No.201437.01C ALTERATIONS HARD DUCT ELBOW. CHECKED BY: RAMAPO COLLEGE OF NEW JERSEY MANUAL VOLUME DAMPER (TYP.) CJZ MECHANICAL LEGEND SCHEDULES DETAILS & CONTROLS SQUARE TO ROUND 45° BOOT TAKE-OFF (TYP.) DRAWN BY: 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 NOTES: FAN TO BE CONTROLLED THROUGH EXISTING EXHAUST HOOD CONTROLS. COORDINATE WITH OWNER PRIOR TO EXHAUST FAN REMOVEL. 3/23/2016 3:28:11 PM NJDCA ELECTRONIC SUBMITTAL STAMP: DEMOLITION GENERAL NOTES 1. 2. 3. 4. DEMOLITION WORK LEGEND 5. 6. EXISTING DUCTWORK, PIPING & EQUIPMENT TO REMAIN 7. DUCTWORK, PIPING & EQUIPMENT TO BE REMOVED POINT OF DISCONNECTION 8. IDENTIFICATION AND/OR ABATEMENT OF HAZARDOUS MATERIALS IS NOT PART OF THIS SCOPE OF WORK. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY. REFER TO SPECIFICATIONS FOR RECYCLING, CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL REQUIREMENTS. OPENING IN THE EXISTING STRUCTURE SMALLER THAN 12" IN ANY DIRECTION ARE NOT IDENTIFIED ON THESE DRAWINGS. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING OPENINGS SMALLER THAN 12" AS REQUIRED FOR INSTALLATION OF THEIR WORK. OPENINGS IN THE EXISTING STRUCTURE SHALL NOT BE MADE WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DO NOT REMOVE ITEMS WHICH JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING. IF HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE ARCHITECT IMMEDIATELY. PROTECT ADJACENT AREAS AND ITEMS "TO REMAIN" DURING DEMOLITION/CONSTRUCTION. REPAIR/REPLACE ITEMS DAMAGED DURING CONSTRUCTION. IF UNANTICIPATED HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE OWNERS REPRESENTATIVE IMMEDIATELY. REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION WORK. REVIEW w/ OWNER TO DETERMINE WHAT, IF ANYTHING, WILL BE REMOVED BY OWNER AND WHAT, IF ANYTHING, IS TO BE SALVAGED & TURNED OVER TO OWNER. SEALED: CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. ARCHITECT: KEYED NOTES D1. REMOVE ALL EXISTING FIN TUBE RADIATION, VALVES AND CONTROLS. 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com ENGINEER: D2. REMOVE SUPPLY DUCTWORK. D3. REMOVE EXISTING SUPPLY GRILLE. D4. EXISTING HWS/R PIPING IN CHASE TO BE REUSED. D5. EXISTING CABINET UNIT HEATER TO BE REMOVED AND REUSED. EXISTING HWS/R PIPING, VALVES AND CONTROLS TO BE REUSED. 5 D6. REMOVE EXISTING SUPPLY DIFFUSER AND PORTION OF BRANCH DUCT. 6 D8. REMOVE SUPPLY DIFFUSER AND BRANCH DUCT BACK TO MAIN. 3/4" HWS/R 8 12"ø 1 1 1 1/4" HWS/R 68"x14" 3 2 12"ø EXISTING HIGH WINDOW FIN TUBE, VALVES & CONTROLS TO REMAIN AND REUSED. MODIFY AS REQUIRED. 1 1/4" HWS/R 1" HWS/R 1 16"x12" 1" HWS/R 3/4" HWS/R 7 2 1 4 40"x14" 1 26"x14" 2 1" HWS/R 12"ø 20"x14" 16"x12" 3/4" HWS/R 1 3/4" HWS/R 3/4" HWS/R 12"ø 1 1 7 4 4 1 FIRST FLOOR DEMOLITION 0 8 16 24 1/8" = 1'-0" NORTH ISSUED: 3.24.2016 DESCRIPTION: BID DOCUMENTS SHEET: MD-100 18031.00 7 3/4" HWS/R PP RCNJ No.201437.01C ALTERATIONS EXISTING HIGH WINDOW FIN TUBE, VALVES & CONTROLS TO REMAIN AND REUSED. MODIFY AS REQUIRED. 4 CHECKED BY: RAMAPO COLLEGE OF NEW JERSEY 8 8 CJZ DEMOLITION FIRST FLOOR 3/4" HWS/R 3/4" HWS/R DRAWN BY: 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 3/4" HWS/R 1" HWS/R REMOVE INSULATION OFF EXISTING SUPPLY DUCT THAT IS TO BE EXPOSED REVISIONS D7. EXISTING HWS/R PIPING, VALVES AND CONTROLS SERVING HIGH WINDOW FIN TUBE RADIATION TO REMAIN, MODIFY AS REQUIRED. 1 1/2" HWS/R 1 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com 3/23/2016 4:03:34 PM NJDCA ELECTRONIC SUBMITTAL STAMP: DEMOLITION GENERAL NOTES 1. 18"x10" 24"x10" 2. 24"x10" 3. 6 12x10 4 4. 2 EXISTING HOOD TO REMAIN ROOF PLAN DEMOLITION - ADD ALTERNATE-1 5. 1/8" = 1'-0" 5 6. 5 7. VAV-9 (E) 8. IDENTIFICATION AND/OR ABATEMENT OF HAZARDOUS MATERIALS IS NOT PART OF THIS SCOPE OF WORK. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY. REFER TO SPECIFICATIONS FOR RECYCLING, CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL REQUIREMENTS. OPENING IN THE EXISTING STRUCTURE SMALLER THAN 12" IN ANY DIRECTION ARE NOT IDENTIFIED ON THESE DRAWINGS. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING OPENINGS SMALLER THAN 12" AS REQUIRED FOR INSTALLATION OF THEIR WORK. OPENINGS IN THE EXISTING STRUCTURE SHALL NOT BE MADE WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DO NOT REMOVE ITEMS WHICH JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING. IF HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE ARCHITECT IMMEDIATELY. PROTECT ADJACENT AREAS AND ITEMS "TO REMAIN" DURING DEMOLITION/CONSTRUCTION. REPAIR/REPLACE ITEMS DAMAGED DURING CONSTRUCTION. IF UNANTICIPATED HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE OWNERS REPRESENTATIVE IMMEDIATELY. REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION WORK. REVIEW w/ OWNER TO DETERMINE WHAT, IF ANYTHING, WILL BE REMOVED BY OWNER AND WHAT, IF ANYTHING, IS TO BE SALVAGED & TURNED OVER TO OWNER. SEALED: CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. 1 FIRST FLOOR DEMOLITION - ADD ALTERNATE-1 ARCHITECT: 1/8" = 1'-0" KEYED NOTES T 9(E) D1. REMOVE EXISTING EXHAUST GRILLE AND 2'-0" PORTION OF EXISTING EXHAUST BRANCH DUCT. PER BASE BID. VAV-10 (E) 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com 1 D2. REMOVE EXISTING SUPPLY DIFFUSER AND ASSOCIATED FLEX DUCT. PER BASE BID. D3. EXISTING CABINET UNIT HEATER TO BE TEMPORARILY DISCONNECTED FROM EXISTING HWS/R PIPING, CONTROLS AND POWER. EXISTING CABINET UNIT HEATER TO BE RELOCATED. MODIFY EXISTING HWS/R PIPING, VALVES & CONTROLS AS REQUIRED AND REUSE. 18"x10" 24"x10" VAV-8 (E) 24"x10" 12x10 D4. REMOVE EXISTING 12x10 GREASE EXHAUST DUCT FROM EXISTING HOOD BACK TO EXTERIOR WALL PENETRATION. PER ADD ALTERNATE-1. 1 ENGINEER: 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com REVISIONS D5. REMOVE EXISTING SUPPLY GRILLE, INSULATE AND PATCH EXISTING SUPPLY DUCT. PAINT TO MATCH EXISTING DUCT COLOR. PER ADD ALTERNATE -1. 2 3 D6. REMOVE EXISTING GREASE EXHAUST HOOD FAN. EXISTING CONTROLS AND ROOF SUPPORTS TO REMAIN AND BE REUSED. PER ADD ALTERNATE -1. 2 VAV-7 (E) VAV-6 (E) 6(E) 10(E) T E T E 1 1/2" HWS/R (E) T 3(E) VAV-4 (E) VAV-3 (E) VAV-5 (E) T T 4(E) 1 1/2" HWS/R 5(E) T E 7 T E VAV-1 (E) T T 1(E) 2(E) DEMOLITION WORK LEGEND VAV-2 (E) CHECKED BY: PP EQUIPMENT TO BE REMOVED EQUIPMENT TO REMAIN T E POINT OF DISCONNECTION T E T E T E ISSUED: 3.24.2016 DESCRIPTION: BID DOCUMENTS 3 FIRST FLOOR DEMOLITION - BASE BID 0 8 16 24 1/8" = 1'-0" SHEET: NORTH MD-110 18031.00 7(E) T T CJZ RCNJ No.201437.01C ALTERATIONS T DRAWN BY: MECHANICAL DEMOLITION FIRST FLOOR T 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 D7. REMOVE EXISTING SUPPLY GRILLE. PER BASE BID. 1 1/2" HWS/R (E) RAMAPO COLLEGE OF NEW JERSEY 8(E) 3/23/2016 3:38:15 PM NJDCA ELECTRONIC SUBMITTAL STAMP: ADDITION/ALTERATION GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. VAV-9 (E) 8. IDENTIFICATION AND/OR ABATEMENT OF HAZARDOUS MATERIALS IS NOT PART OF THIS SCOPE OF WORK. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY. REFER TO SPECIFICATIONS FOR RECYCLING, CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL REQUIREMENTS. OPENING IN THE EXISTING STRUCTURE SMALLER THAN 12" IN ANY DIRECTION ARE NOT IDENTIFIED ON THESE DRAWINGS. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING OPENINGS SMALLER THAN 12" AS REQUIRED FOR INSTALLATION OF THEIR WORK. OPENINGS IN THE EXISTING STRUCTURE SHALL NOT BE MADE WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DO NOT REMOVE ITEMS WHICH JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING. IF HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE ARCHITECT IMMEDIATELY. PROTECT ADJACENT AREAS AND ITEMS "TO REMAIN" DURING DEMOLITION/CONSTRUCTION. REPAIR/REPLACE ITEMS DAMAGED DURING CONSTRUCTION. IF UNANTICIPATED HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE OWNERS REPRESENTATIVE IMMEDIATELY. REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION WORK. REVIEW w/ OWNER TO DETERMINE WHAT, IF ANYTHING, WILL BE REMOVED BY OWNER AND WHAT, IF ANYTHING, IS TO BE SALVAGED & TURNED OVER TO OWNER. SEALED: CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. ARCHITECT: KEYED NOTES T 9(E) VAV-10 (E) 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com EXISTING HOOD EXHAUST UP TO EXISTING FANS (TYP. 4) ENGINEER: 300 CFM 18"x10" 24"x10" VAV-8 (E) 24"x10" 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com 300 CFM 12"x10" REVISIONS VAV-7 (E) 30"x12" 30"x12" 1"HWS/R 3/4" HWS/R T INSTALL 3/4" HWS/R HIGH AND TIGHT TO CEILING ALONG WALL 6(E) 10(E) T S INSTALL 3/4" HWS/R DN ALONG COLUMN IN ENCLOSURE 30"x14" T S PAINT ALL EXISTING AND NEW EXPOSED DUCT. COLOR SELECTION BY ARCHITECT. FTR-2 1 1/2" HWS/R (E) T 68"x20" EXISTING HIGH WINDOW FIN TUBE, VALVES & CONTROLS TO REMAIN AND REUSED. MODIFY AS REQUIRED. 3(E) 26"x14" 40"x14" 3/4" HWS/R (E) 1.5 GPM 2.5 GPM VAV-4 (E) VAV-3 (E) VAV-5 (E) 3/4" HWR DN PROVIDE PIPE CHASE TO MATCH ADJACENT WALL 26"x14" 1 1/4" HWS/R T T 1 1/2" HWS/R 4(E) T S 1" HWS/R DN IN WALL 3.5 EXISTING HIGH WINDOW FIN TUBE, VALVES & CONTROLS TO REMAIN AND REUSED. MODIFY AS REQUIRED. FTR-1 (RF-5) CURVED RUNTAL WALL HUNG 1 1/4" HWS/R 5(E) T S 3/4" HWS/R 1 1/2" HWS/R 1 1/4" HWS/R FTR-3 UFLT-4 VAV-1 (E) T T 1(E) 3/4" HWS (E) UP PP 7(E) T T CHECKED BY: FTR-3 UFLT-4 300 CFM EXISTING DUCT UP TO EXISTING MAKE-UP AIR UNIT CJZ FIRST FLOOR ALTERATION/ADDITION 30"x22" DRAWN BY: RCNJ No.201437.01C ALTERATIONS T 2(E) VAV-2 (E) 1 1/4" HWS/R T FTR-3 UFLT-2 S 1" HWS/R DN IN WALL SERVING FTR-1 & 2 1" HWS/R 3/4" HWS/R (E) FTR-3 FTR-1 (RF-5) CURVED RUNTAL WALL HUNG (TYP. 3 SECTIONS) RUN PIPING BEHIND COLUMN IN WALL RUN PIPING BEHIND COLUMN IN WALL FTR-3 T 3/4" HWR (E) UP T S UFLT-4 S T SFTR-3 2.5 GPM FTR-3 UFLT-4 CONNECT NEW FTR-3 TO EXISTING HWS/R DN IN EXISTING CHASE FTR-3 UFLT-4 CONNECT NEW FTR-3 TO EXISTING HWS/R DN IN EXISTING CHASE ISSUED: 3.24.2016 DESCRIPTION: BID DOCUMENTS 1 FIRST FLOOR - RENOVATION 0 8 16 24 1/8" = 1'-0" SHEET: NORTH M-100 18031.00 1 1/2" HWS/R (E) 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 VAV-6 (E) 8(E) RAMAPO COLLEGE OF NEW JERSEY 300 CFM 14"x8" 3/23/2016 4:09:10 PM NJDCA ELECTRONIC SUBMITTAL STAMP: ADDITION/ALTERATION GENERAL NOTES 1. EXISTING HOOD EXHAUST UP TO EXISTING FANS (TYP. 4) 2. 18"x10" 3. 6 24"x10" 24"x10" 20"x12" 5 4. 2 5. ROOF PLAN ALTERATION - ADD ALTERNATE-1 1/8" = 1'-0" 6. D-F 330 CFM (TYP. 2) 8"ø 8"ø 7. 14"x8" 30"x12" 8. VAV-9 (E) 1.5 gpm IDENTIFICATION AND/OR ABATEMENT OF HAZARDOUS MATERIALS IS NOT PART OF THIS SCOPE OF WORK. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY. REFER TO SPECIFICATIONS FOR RECYCLING, CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL REQUIREMENTS. OPENING IN THE EXISTING STRUCTURE SMALLER THAN 12" IN ANY DIRECTION ARE NOT IDENTIFIED ON THESE DRAWINGS. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING OPENINGS SMALLER THAN 12" AS REQUIRED FOR INSTALLATION OF THEIR WORK. OPENINGS IN THE EXISTING STRUCTURE SHALL NOT BE MADE WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DO NOT REMOVE ITEMS WHICH JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING. IF HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE ARCHITECT IMMEDIATELY. PROTECT ADJACENT AREAS AND ITEMS "TO REMAIN" DURING DEMOLITION/CONSTRUCTION. REPAIR/REPLACE ITEMS DAMAGED DURING CONSTRUCTION. IF UNANTICIPATED HIDDEN ELEMENTS OR DETERIORATED ELEMENTS ARE ENCOUNTERED, NOTIFY THE OWNERS REPRESENTATIVE IMMEDIATELY. REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION WORK. REVIEW w/ OWNER TO DETERMINE WHAT, IF ANYTHING, WILL BE REMOVED BY OWNER AND WHAT, IF ANYTHING, IS TO BE SALVAGED & TURNED OVER TO OWNER. SEALED: CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZED REPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT. DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTS SHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED IN FIELD. 1 FIRST FLOOR ALTERATION - ADD ALTERNATE-1 ARCHITECT: 1/8" = 1'-0" KEYED NOTES VAV-10 (E) 1 gpm EXISTING HOOD EXHAUST UP TO EXISTING FANS (TYP. 4) T 9(E) M1. CABINET UNIT HEATER (CUH-1) TO BE HUNG FROM ROOF STRUCTURE, FLUSH WITH CEILING. PROVIDE TEMPERATURE SENSOR IN RETURN AIR GRILLE PORTION OF CEILING MOUNTED CABINET UNIT HEATER, COORDINATE WITH LIGHTING AND SPRINKLER PIPING. INTEGRATE INTO EXISTING BUILDING MANAGEMENT SYSTEM. PER BASE BID. R-A 450 CFM 3 M2. EXISTING CABINET UNIT HEATER TO BE TEMPORARILY DISCONNECTED FROM EXISTING HWS/R, CONTROLS & POWER. EXISTING CABINET UNIT HEATER TO RELOCATED. MODIFY EXISTING HWS/R PIPING AND CONTROLS AS REQUIRED AND REUSE. PER BASE BID. 300 CFM 18"x10" 24"x10" VAV-8 (E) 1 gpm 24"x10" 400 CFM 3 300 CFM R-A 300 CFM 2 T 350 CFM 4 1 1/2" HWS/R 28 GPM 30"x12" 1" HWS/R 4.5 GPM D-C 200 CFM WALL MOUNTED 300 CFM EXISTING DUCT UP TO EXISTING MAKE-UP AIR UNIT T 7(E) T T 6(E) 10(E) 400 CFM 30"x14" T T VOLUME DAMPER E PAINT ALL EXISTING AND NEW EXPOSED DUCT. COLOR SELECTION BY ARCHITECT. E 3/4" HWS/R DN ALONG COLUMN 1.5 gpm 1 VOLUME DAMPER T 68"x20" CUH-1 3(E) 26"x14" VAV-4 (E) 1.5 gpm 40"x14" EXISTING GRILLE 400 CFM (TYP. 5) VAV-3 (E) 1.5 gpm VAV-5 (E) 1.5 gpm 26"x14" T 5(E) T E T 4(E) 68"x20" D-E CENTER NEW DUCT MAIN 1000 CFM OVER NEW CEILING T PAINT ALL NEW EXPOSED DUCT. COLOR SELECTION BY ARCHITECT. D-E 1000 CFM E PAINT ALL NEW EXPOSED DUCT. COLOR SELECTION BY ARCHITECT. 36"x8" VOLUME DAMPER INSTALL DUCT TIGHT TO BEAM 1 1/4" HWS/R 8 GPM 18"ø VAV-1 (E) .5 gpm T T 1(E) 18"ø T E D-A 250 CFM (TYP. 6) NEW DUCTWORK & EQUIPMENT 10" DIA. (TYP. 6) T E PP VAV-2 (E) .5 gpm BALANCE DAMPER D-B 300 CFM DUCT MOUNTED (TYP. 16) 2(E) RENOVATION WORK LEGEND 36"x18" CHECKED BY: M6. PROVIDE EXHAUST FAN (EF-1). MODIFY EXISTING FAN SUPPORT BASE AS REQUIRED TO MOUNT EXHAUST FAN (EF-1) MAINTAIN ROOF INTEGRITY TO BE WEATHER TIGHT. CONNECT EXISTING WOK EXHAUST HOOD CONTROLS TO NEW EXHAUST FAN (EF-1). PER ADD ALTERNATE-1. 30"x12" VOLUME DAMPER CJZ EXISTING DUCTWORK & EQUIPMENT D-B 200 CFM DUCT MOUNTED (TYP. 4) POINT OF CONNECTION 1 1/4" HWS/R 16"ø T E T E ISSUED: 3.24.2016 DESCRIPTION: BID DOCUMENTS SHEET: 3 FIRST FLOOR ALTERATION - BASE BID 0 8 16 M-110 24 1/8" = 1'-0" NORTH 18031.00 VAV-6 (E) 1.5 gpm 8(E) DRAWN BY: 505 RAMAPO VALLEY RD. MAHWAH, NJ 07430 VAV-7 (E) 1 gpm 300 CFM M5. PROVIDE 20x12 GREASE EXHAUST DUCT AND ASSOCIATED FIRE RATED DUCT ACCESS DOORS. CONNECT NEW 20x12 DUCT TO EXISTING GREASE EXHAUST HOOD AND EXISTING EXTERIOR 20x12 GREASE EXHAUST DUCT. PER ADD ALTERNATE - 1. D-D 200 CFM (TYP. 2) RCNJ No.201437.01C ALTERATIONS 400 CFM 350 CFM 30"x22" REVISIONS RAMAPO COLLEGE OF NEW JERSEY 400 CFM 49 Court Street | P.O. Box 1980 | Binghamton, NY 13902 Tel: 607-723-9421 | mjinc.com M4. PROVIDE NEW SUPPLY DIFFUSER (D-D). PROVIDE NEW BRANCH DUCTWORK AS REQUIRED FOR DIFFUSER TO FIT IN NEW CEILING GRID. NEW SUPPLY DUCT TO BE SAME SIZE AS EXISTING BRANCH DUCT. PER BASE BID. 1.5 gpm 4 ENGINEER: MECHANICAL ALTERATIONS FIRST FLOOR 400 CFM M3. PROVIDE NEW EXHAUST GRILLE (R-A). PROVIDE NEW BRANCH DUCTWORK AS REQUIRED FOR GRILLE TO FIT IN NEW CEILING GRID. NEW EXHAUST DUCT TO BE SAME SIZE AS EXISTING BRANCH DUCT. PER BASE BID. 1656 Massachusetts Ave. | Lexington, MA 02420 Tel: 781-652-0114 | connorarchitecture.com