CADD DETAIL NO. : SD142100-01.DWG 4'-0" 4'-0" [1200mm] [1200mm] . 5" [125 mm] . 2 3/4" [70mm] 8'-2" MIN. 2. HOISTWAY [300mm] [1800mm] PLATFORM PLAN "A" A CONCRETE OR 20 GA. METAL CAR [55mm] NOT BETWEEN 6'-0" CAR POSSIBLE. FRONT AND REAR OPENINGS PLAN "C" HOISTWAY EXTERIOR BOTTOM CAB FLOOR FLOOR METAL SILL 5" [125mm] [55mm] 2 1/4" [1800mm] SLAB DEPRESSION ELEVATOR ON OUTSIDE WALLS, ELEVATORS WHEN STRUCTURAL SLAB FOR METAL SILL 9 HOISTWAY COUNTERWEIGHTS [2550mm] 12" CAB FLOOR LOCATE SIDE 8'-6" HOISTWAY 5" [125mm] . METAL SILL TOP ONLY [450mm] TOP FLOOR ° [2825mm] A 75 2 1/4" ATTACHED AT 1'-6" MIN. OR PENTHOUSE FLOOR CAR DEFLECTOR [300mm] MACHINE ROOM 6 1/2" [162mm] 2 1/2" [62mm] TOP DEFLECTOR FROM PROJECTING BEAM IN ELEVATOR HOISTWAYS AS REQ'D. [1200mm] 12" MIN. 5" [125mm] PLAN "B" 4'-0" 9'-5" CAR STUDS. 4000 AT REAR OF PLATFORM AS REQ'D. COUNTERWEIGHTS ON SIDE OF CMU OR METAL AS REQUIRED 1'-6" COUNTERWEIGHT PARTITION WALLS TRAVEL . [1800mm] [450mm] CLEAR HEIGHT 6 1/4" [160mm] 6'-0" CAR [300mm] MACHINE PLATFORM [2250mm] [450mm] HOISTWAY 7'-6" MIN. [2550mm] 1'-6" MIN. [3010mm] ROOF SLAB 6'-0" CAR 8'-6"MIN. HOISTWAY 9'-10 1/2" [300mm] 1/2" x 2 1/2" [240mm x 62mm] 6 1/2" [162mm] 2 1/2" [62mm] 5" [125mm] . PIT STRUCTURAL SLAB SLAB DEPRESSION FOR METAL SILL 9 1/2" x 2 1/2" (240mm x 62mm) SECTION "A-A" NONE 12" SEE DETAIL 14 21 00-02 OR 14 21 00-08 FOR ENTRANCE DETAILS. SCALE : [300mm] 3. 12" MIN. LB. CAPACITY 12" MIN. SEE STRUCTURAL DRAWINGS FOR ACTUAL SIZE & LOCATION OF COLUMN, BEAMS AND SLAB. [2600mm] 8'-8" CAR [2600mm] 8'-8" CAR [2450mm] COORDINATE WALL TYPE & FINISH WITH ARCHITECTURAL DRAWINGS. PASSENGER 2 3/4" [70mm] 1. DETAIL TITLE / HOISTWAY DETAIL - ELEVATORS, (TWO SPEED SLIDING DOORS) . . 5" [125 mm] NOTES: DATE ISSUED :DECEMBER 2008 COUNTERWEIGHTS METAL FRAME FACE OF WALL SEE CENTERLINE FINISH SCHEDULE SIGHT GUARD PASSENGER ELEV. [114mm] 3/16" [5mm] BENT PLATE HEADER BOLTED TO CLOSER ANGLE EDGE OF MASONRY 4" MIN. [102mm] OPENING BELOW BEARING FOR LINTEL FIN. JAMB BELOW FACE OF DOOR NON-SLIP METAL SILL EMERGENCY RUBBER KEYWAYS ALL BUMPER LANDINGS DOOR STRUT STOP ANGLE M.B. JAMB BRACKET BASE FINISHED FLOOR 1/2" [14mm] M.B. GROUT 4 PR. SILL SOLID BRACKETS OR 3/8" [10mm] M.B. 3/8" [10mm] FOUR Z BARS E.B. 9 1/2" [241mm] [1219mm] PASS. ELEV. ELEVATION OF DOORS PLATE 1" MIN. [25mm] 1 1/2" [38mm] LINTEL COPED AT EACH END CAULK 3/4" [19mm] 1" [25mm] TRIM AT HEAD 3/16" [5mm] BENT PLATE LINTEL BELOW SECTION "A-A" NOTES: 1. HEAD AND JAMBS OF FINISHED FRAME SHALL BE SECURED TOGETHER WITH CONTINUOUS WELD. 2. ALL METAL GAGES AND FINISHES OF FRAME AND DOORS AS SPECIFIED. 20 GA. FASCIA SILL DEPRESSION 9 1/2"x2 1/2" MIN. [241x64mm] 4'-0" 6" 1/4" 3/8" [10mm] WALL 1 1/8" [29mm] 7/8"± [22mm] 1/4" [6mm] [32mm] A [2134mm] [6mm] ANGLE 7'-0" 1 1/4" A CLOSER 3. FOR TOP FLOOR DUST COVER AND BOTTOM FLOOR TOE GUARD, SEE STANDARD DETAIL No. 14 21 00-03. 4. DOORS MAY BE RIGHT OR LEFT HAND - ARCHITECT TO SPECIFY. ENTRANCE DETAILS - SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR NTS (TWO SPEED SLIDING DOORS) SEE PLANS HEADER [6mm] 1/4" 2"x2"x1/8" SILL CLIP [51x51x3mm] FASCIA PLATE 6'-0" DOOR [1676mm] [19mm] 1/4" [32mm] FIN. FLOOR WALL LINE PLAN [1829mm] [6mm] 1 1/4" HEAD [64mm] [114mm] FINISH WALL VARIES 3/4" [6mm] 7'-0" [2134mm] FRAME 2 1/2" MIN. 4 1/2"± 5'-6" 1/4" METAL # 4'-0" [1219mm] HANGER COVER 12 GA SILL 4 1/2"± OF PENDANT BOLTS TOP & BOTTOM GROUT SOLID 4 ADJ. STRAP ANCHORS EA. SIDE DOOR STOP AT CAD DETAIL NO.: DATE ISSUED: DECEMBER 2008 STRUT ANGLE HEATER BOLTED TO R 2" 1/ m] 3 9m [8 (TWO SPEED SLIDING DOORS) SILL CLIP [152mm] [51mm] 2" [29mm] 1 1/8" [32x32x5mm] 3/16" [5mm] PL. CLOSER ANGLE [76x76x10mm] DETAILS HEADER [76x76x10mm] 3"x3"x3/8" 1/4" [6mm] 1/4" BENT PLATE [6mm] REQUIRED SECURED TO [86mm] 3 3/8" DEADENING COVER AS [248mm] SOUND 1/4" HANGER CONT. 1 1/4"x1 1/4"x 3/16" 9 3/4" CAULK C L OPENING STRUT ANGLE METAL 20GA ENDS [29mm] 3"x3"x3/8" HOUSING LINTEL 1 1/2" [38mm] BENT PLATE CLOSED [6mm] 1 1/8" TO STRUT ANGLE HANGER 1/4" [6mm] 3/16" [5mm] BOX SCALE : NONE SILL PL. WELDED FIXTURE SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR BOTTOM DETAIL TITLE / ENTRANCE & INDICATOR [165mm] BUMPER DOOR STOPS TOP 6 1/2" RUBBER SEE PLANS 3/16" [5mm] BENT PLATE HEADER CONC. BELOW WALL VARIES FLOORS FACE OF SILL MIN. FIRE RATING OVER TRAVEL [165mm] TOP & BOTTOM METAL SILL 6 1/2" HOISTWAY ACCESS TO SILL ABOVE [127mm] PLATE CONT. ANGLE 1" [25mm] [25mm] 1 1/2" [38mm] STRUT 5" SCHEDULE WALL VARIES SEE PLANS 2 HR. 1" MIN. SEE FINISH GLIDE GROOVES 3/4" [19mm] 1/4" [6mm] FACE OF WALL 3/16" [5mm] 3/8" [10mm] NON-SLIP 20 GA. FASCIA 3/4" [19mm] 1/4" [6mm] METAL SILL SIGHT GUARD SD142100-02.DWG OVERALL SILL [450mm] 9'-7" HOISTWAY [2900mm] [2000mm] [300mm] [3100mm] COUNTERWEIGHTS ON 8'-6" CAR BETWEEN ELEVATORS [2550mm] WHEREVER POSSIBLE. COUNTERWEIGHT 4'-0" 1'-6" [1200mm] CENTER OPENING [450mm] COUNTERWEIGHT 3 1/2" [90mm] 2 3/4" [70mm] TOP OF MACHINE BEAMS SHALL BE FLUSH WITH OR BELOW MACHINE ROOM FLOOR SLAB. 10'-2" HOISTWAY LOCATE OUTSIDE WALL NOT 9'-1/2" CAR [2712mm] 6. MACHINE ROOM - APPROXIMATELY 225 SQ. FT. (21 SQ. M) PER MACHINE. ROOF SLAB MACHINE PLATFORM PARTITION WALL MASONRY OR METAL DOORS STUD PLAN "A" PLAN "B" CAR WITH FRONT AND REAR ENTRANCES NOTE: AVOID REAR ENTRANCE WHERE POSSIBLE. TOP CAB 20 GA. METAL FLOOR FACE OF . 30° WALL . 6" [150mm] HOISTWAY BOTTOM FLOOR 20 GA. HOISTWAY EXTERIOR 20 GA. DUST COVER BOLTED DUST COVER TO WALL TOP DEFLECTOR PROJECTING BEAM IN HOISTWAY 2 3/4" [70mm] 3 1/2" [90mm] BOTTOM FLOORTOE GUARD AT SILL SLAB DEPRESSION FOR METAL SILL 8" x 2 1/2" [200mm x 62mm] 5" [125 mm] METAL SILL 2 3/4" [70mm] 3 1/2" [90mm] FIN. FLOOR CAR CAB FLOOR 1 1/4" [30mm] 1 1/2" [37mm] AS REQ'D. TOP FLOOR-DUST COVER AT HEAD ELEVATOR FACE OF WALL [450mm] 30° TOP ONLY 1'-6" TO WALL [125 mm] 1 1/4" [30mm] 1 1/2" [37mm] SILL FIN. FLR. . BOLTED 75° ATTACHED AT 5" FIN. FLOOR CONCRETE OR DEFLECTOR OR PENTHOUSE FLOOR CAR FLOOR MACHINE ROOM PIT SLAB DEPRESSION METAL SILL SECTION "A-A" 5000 LB. CAPACITY [2000mm] [300mm] 5. ELEVATOR, SERVICE [300mm] 12" DETAIL TITLE / 1'-6" MIN. 6'-8" CAR AS REQ'D. 6'-8" CAR 12" MIN. AS REQUIRED 12" MIN. CONCRETE MACHINE ROOM FLOOR(S) NOT TO BE POURED UNTIL MACHINES ARE ON MACHINE BEAMS. [2600mm] TRAVEL [2750mm] 4. 8'-8" HOISTWAY CONCRETE 9'-2" HOISTWAY OPENING DOORS. A FACE OF SEE 14 21 00-04.DWG FOR DETAILS OF HORIZONTAL SLIDING CENTER HEIGHT A CADD DETAIL NO. : SD142100-03.DWG 3. DOORS DATE ISSUED :DECEMBER 2008 A OPENING (HORIZONTAL SLIDING CENTER OPENING DOORS) DOORS CENTER SEE STRUCTURAL DRAWINGS FOR ACTUAL SIZE AND LOCATION OF COLUMNS, BEAMS AND SLABS. NONE A 2. [1200mm] MIN CLEAR CENTER OPENING 4'-0" COORDINATE WALL TYPE AND FINISH WITH ARCHITECTURAL DRAWINGS. 7'-6" [2250mm] [1200mm] 1. SCALE : 3 1/2" [90mm] 2 3/4" [70mm] 3 1/2" [90mm] 2 3/4" [70mm] 4'-0" NOTES: ACCESS KEY SWITCH AND BOX TOP & HANGER COVER 5'-6" SIGHT GUARD [1676mm] 12 GA HEADER [19mm] 1/4" FIN. FLOOR BOLTED TO 1/4" 3/8" [10mm] M.B. JAMB BRACKET LANDINGS TYPICAL NARROW RUBBER BUMPER AS APPROVED DOOR EXTRUDED OR STOP HOUSING HEAD SECTION TOP LANDING EDGE OF MASONRY CAST FINISHED 4'-0" FLOOR [1219mm] BASE PASS. ELEV. BOTTOM TOE GUARD 4" MIN. [102mm] OPENING BELOW BEARING FOR LINTEL FIN. JAMB BELOW 1/4" [6mm] GUIDES HANGER KEYWAYS ALL NON-SLIP SILL [5mm] [6mm] REMOVABLE 3 WALL EMERGENCY ANGLE ° 0 DUST COVER A STRUT WALL NO. 14 GA. [6mm] DOOR BOLTED TO 1 1/2" [38mm] [32mm] A 7'-0" [2134mm] FASCIA PLATE 3/4" [6mm] 1 1/4" HEAD 2"x2"x1/8" SILL CLIP [51x51x3mm] OVAL HEAD MACH. ELEVATION OF DOORS SCREW 12" 6 PR. SILL SOLID BRACKETS OR 3/8" [10mm] M.B. 3/8" [10mm] E.B. 1" MIN. 8" [25mm] [203mm] NOTES: 1. CONTINUOUS WELD. PLATE [38mm] HEAD AND JAMBS OF FINISHED FRAME SHALL BE SECURED TOGETHER WITH 14 GA. FASCIA 1 1/2" AT EACH END CAULK 1/2" [14mm] M.B. FIVE Z BARS LINTEL COPED 2. ALL METAL GAGES AND FINISHES OF FRAME AND DOORS AS SPECIFIED. 1 1/8" [29mm] 7/8"± [22mm] 1/4" [6mm] GROUT FACE OF WALL [300mm] O.C. [64mm] 2 1/2" MIN. 7'-0" FRAME PLAN 6" [51mm] 1/4" CLEAR OPENING 3/4" [19mm] 1" [25mm] TRIM AT HEAD 3/16" [5mm] BENT PLATE LINTEL BELOW SECTION "A-A" SILL # ENTRANCE DETAILS - SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR NTS (HORIZONTAL SLIDING CENTER OPENING DOORS) CAD DETAIL NO.: DATE ISSUED: DECEMBER 2008 [114mm] (HORIZONTAL SLIDING CENTER OPENING DOORS) 4 1/2"± [1219mm] SCALE : NONE 4'-0" [114mm] DETAILS 4 1/2"± FACE OF WALL SEE 2" OF PENDANT BOLT METAL GROUT SOLID CAULK JAMBS AT SILL. FINISH SCHEDULE CENTERLINE STRUCT ANGLE SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR ANGLES WELDED TO 3/16" [5mm] PLATE HEADER BOLTED TO DETAIL TITLE / ENTRANCE 1/4" [51x51mm] CLIP 6'-0" [51mm] 2" [29mm] [6mm] 1 1/8" 1/4" METAL FRAME [1829mm] [86mm] SOUND DEADENING 2"x2"x12 GA GUIDE GROOVE 2" 1/ m] 3 9m [8 DEADENING [127mm] HEADER [32x32x5mm] LINTEL CONC. BELOW R SOUND ANCHORS EA. SIDE 5" SECURED TO BENT PLATE ASTRAGALS 30° 3/16" [5mm] BENT PLATE 4 ADJ. STRAP [152mm] CONT. 1 1/4"x1 1/4"x3/16" [2134mm] CAULK [29mm] NEOPRENE 18" TOP & BOTTOM FACE OF 7/8"± AS REQUIRED C L OPENING [22mm] ENDS BUMPER 1/4" [6mm] DOOR STOPS [250mm] RUBBER HANGER COVER 9 3/4" 1 1/8" METAL 20GA CLOSED 1/2" BOX [6mm] [15mm] STRUT ANGLE SEE PLANS [76x76x10mm] SEE PLANS FIXTURE TRAVEL [25mm] [105mm] 3"x3"x3/8" 3/4" [19mm] WALL VARIES INDICATOR 1/4" [6mm] OVER [457mm] STRUT ANGLE 1" SIGHT GUARDS WALL VARIES WELDED HOUSING [6mm] 1/4" HANGER NON-SLIP METAL SILL 4 1/4"± 3/16" [5mm] BENT PLATE HEADER 3 3/8" 1" [25mm] SILL PLATE [25mm] 1 1/2" [38mm] ANGLE MIN. FIRE RATING SCHEDULE 1" MIN. SEE PLANS 2 HR. METAL SILL 6" SEE FINISH BOTTOM FLOOR LANDINGS TO SILL ABOVE [150mm] FACE OF WALL STRUT SILL PLATE CONT. WALL VARIES SD142100-04.DWG OVERALL SILL 14 GA. FASCIA CADD DETAIL NO. : SD142100-05.DWG AND PIT DEPTHS FOR 4000# [1840 kg] CAPACITY PASSENGER ELEVATORS OVERHEAD MACHINES WITHOUT WITH SECONDARY SECONDARY SLAB SLAB DISTANCE FROM TOP OF FINISHED PITS MACHINE ROOM FLOOR TO UNDERSIDE OF SECONDARY SLAB 100 (0.5) GEARED 16'-6" [5000mm] 5'-6" [1650mm] 150 (0.8) GEARED 16'-6" [5000mm] 5'-6" [1650mm] 200 (1.0) GEARED 16'-6" [5000mm] 5'-6" [1650mm] 250 (1.3) GEARED 18'-0" [5450mm] 7'-0" [2100mm] 300 (1.5) GEARED 18'-0" [5450mm] 7'-0" [2100mm] 350 (1.8) GEARED 18'-6" [5600mm] 7'-0" [2100mm] 400 (2.0) GEARLESS 24'-3" [7376mm] 6'-3" [1875mm] 8'-8" [2600mm] 450 (2.3) GEARLESS 24'-3" [7376mm] 6'-3" [1875mm] 8'-8" [2600mm] 500 (2.5) GEARLESS 25'-3" [7675mm] 6'-3" [1875mm] 10'-0" [3000mm] 600 (3.0) GEARLESS 27'-0" [8200mm] 6'-3" [1875mm] 12'-6" [3800mm] 700 (3.5) GEARLESS 28'-0" [8500mm] 6'-3" [1875mm] 12'-6" [3800mm] CLEAR MACHINE ROOM WITHOUT TROLLEY BEAMS 7'-6" [2250mm] MIN. CLEAR MACHINE ROOM WITH TROLLEY BEAMS 10'-0" [3000mm] MIN. NOTES: 1. DIMENSIONS ARE FOR PRELIMINARY PLANNING ONLY. ELEVATOR ENGINEER SHOULD BE CONSULTED RELATIVE TO CLEARANCES REQUIRED FOR SPECIFIC PROJECTS. 2. GEARLESS HOISTING MACHINES SHALL BE CONSIDERED FOR RISES OF 100 FEET [30480mm] OR MORE. NONE ROOM FLOOR OR PLATFORM SCALE : LANDING TO FINISHED MACHINE VERTICAL DIMENSIONS MACHINE HOISTWAYS FT./MIN. (M/SEC) DISTANCE FROM TOP OF 4000 LB. CAPACITY PASSENGER TYPE OF DETAIL TITLE / ELEVATOR SPEEDS DATE ISSUED :FEBRUARY 2008 SCHEDULE OF APPROXIMATE OVERHEAD HEIGHTS CADD DETAIL NO. : SD142100-06.DWG UP TO 5000# [2268 kg] CAPACITY PASSENGER/SERVICE ELEVATORS OVERHEAD MACHINES ROOM FLOOR OR PLATFORM WITHOUT WITH SECONDARY SECONDARY SLAB SLAB UNDERSIDE OF SECONDARY SLAB GEARED 17'-0" [5150mm] 5'-6" [1650mm] 150 (0.8) GEARED 17'-6" [5300mm] 5'-6" [1650mm] 200 (1.0) GEARED 17'-6" [5300mm] 5'-8" [1700mm] 250 (1.3) GEARED 18'-0" [5450mm] 6'-6" [1950mm] 300 (1.5) GEARED 18'-0" [5450mm] 6'-6" [1950mm] 350 (1.8) GEARED 18'-0" [5450mm] 6'-11" [2075mm] 400 (2.0) GEARLESS 24'-3" [7375mm] 5'-3" [1575mm] 8'-8" [2600mm] 450 (2.3) GEARLESS 24'-3" [7375mm] 6'-3" [1875mm] 8'-8" [2600mm] 500 (2.5) GEARLESS 24'-6" [7450mm] 6'-3" [1875mm] 9'-6" [2850mm] 600 (3.0) GEARLESS 25'-8" [7800mm] 6'-3" [1875mm] 10'-2" [3100mm] 700 (3.5) GEARLESS 26'-10" [8150mm] 6'-3" [1875mm] 11'-2" [3400mm] NOTES: DIMENSIONS ARE FOR PRELIMINARY PLANNING ONLY. CONSULTED RELATIVE TO 2. PITS MACHINE ROOM FLOOR TO 100 (0.5) CLEAR MACHINE ROOM 7'-6" [2250mm]. 1. DISTANCE FROM TOP OF FINISHED GEARLESS HOISTING MACHINES SHALL BE CONSIDERED [30480mm] OR MORE. ELEVATOR ENGINEER SHOULD BE CLEARANCES REQUIRED FOR SPECIFIC PROJECTS. FOR RISES OF 100 FEET NONE LANDING TO FINISHED MACHINE SCALE : FT./MIN. (M/SEC) MACHINE DISTANCE FROM TOP OF VERTICAL DIMENSIONS TYPE OF DETAIL TITLE / ELEVATOR HOISTWAYS 2000 LB. CAPACITY PASSENGER/SERVICE ELEVATORS SPEEDS DATE ISSUED :DECEMBER 2008 SCHEDULE OF APPROXIMATE OVERHEAD HEIGHTS AND PIT DEPTHS [450mm] . 12" MIN. COUNTERWEIGHT CADD DETAIL NO. :SD142100-07.DWG 1'-6" MIN. VARIATIONS FROM THIS DIMENSION [450mm] COUNTERWEIGHT [300mm] MACHINE 7'-6" PLATFORM [2250mm] ROOF SLAB 12" MIN. [300mm] EDGE OF METAL SILL FACE OF CONCRETE "A" VARIES 5" [125mm] 2 3/4" [70mm] 3 1/2" [90mm] EQUAL 4'-0" [1200mm] EQUAL VARIES C.O. DOORS 4'-0" [1200mm] C.O. DOORS 3 1/2" [90mm] 2 3/4" [70mm] VARIES PUSH BUTTON PT LADDER AT DIVISION BEAM, SEE VA DETAIL 33 METAL SILL FIN. FLOOR PLATFORM PLAN TOP FLOOR VARIBLE CAR DIMENSIONS [1814 KG] A 9'-10" [3000mm] 10'-0" [3050mm] B 7'-10" [2350mm] 8'-0" [2400mm] C 7'-6" [2250mm] 7'-8" [2300mm] D 20'-0" [6000mm] 20'-4" [6200 mm] E 4'-10 3/4" [1470mm] 5'-3 3/4" [1595mm] F 7'-5 3/4" [2245mm] 7'-10 3/4" [2405mm] G 5'-9" [1725mm] 6'-2" [1850mm] H 7'-9 1/4" [2331mm] 8'-2 1/4" [2456mm] 30° 20 GA. METAL DEFLECTOR ATTACHED AT TOP ONLY HOISTWAY EXTERIOR TOP DEFLECTOR FOR PROJECTING BEAM IN HOISTWAY NOTES: 1. ELEVATOR TRAVEL [1580 KG] PLATFORM COORDINATE WALL TYPE AND FINISH. 2. COORDINATE ACTUAL SIZE AND LOCATION OF COLUMNS, BEAMS AND SLAB WITH STRUCTURAL. 3. SEE DRAWING NO. 14210-04.DWG FOR ENTRANCE DETAILS. 4. CONCRETE FLOOR(S) NOT TO BE POURED UNTIL MACHINES ARE IN PLACE. 5. MACHINE ROOM - APPROXIMATELY 225 SQ. FT. (21 SQ. M) PER MACHINE. 6. MACHINE BEAMS SHALL BE FLUSH OR BELOW MACHINE. SLAB DEPRESSION RUNNING CLEAR FOR METAL SILL 8' 1 1/4" [30mm] SILL PROJECTION 1 1/2" [37mm] 3 1/2" [90mm] 2 3/4" [70mm] 5" x 2 1/2" MIN. [2440mm x 62mm] [125mm] METAL SILL FIN. FLOOR PLATFORM BOTTOM FLOOR WITH SPEED 4000 LB. CAP. PIT DEPTH VARIES 3500 LB. CAP. PLATFORM RUNNING CLEAR 1 1/4" [30mm] SILL PROJECTION 1 1/2" [37mm] PIT FLOOR SECTION "A - A" SLAB DEPRESSION SCALE : STUD. NONE CMU OR METAL ELEVATOR INSIDE FIN. WALLS "H" MIN. BETWEEN HOISTWAY "G" PLATFORM [100 mm] "F" CLEAR "E" INSIDE CAR 4" PARTITION WALLS- HORIZONTAL SLIDING CENTER OPENING DOORS "C" INSIDE CAR "D" MIN. CLEAR HOISTWAY DETAIL TITLE / PASSENGER "C" INSIDE CAR HEIGHT AS REQUIRED "B" PLATFORM AS "B" PLATFORM REQ'D. "A" CLEAR HOISTWAY "G" PLATFORM "A" "F" CLEAR HOISTWAY "E" INSIDE CAR 12" MIN. [305mm] MIN. CLEAR "A" CLEAR HOISTWAY DATE ISSUED :DECEMBER 2008 NOTE: SEE STRUCTURAL DWGS. FOR 1'-6" MIN. ACCESS KEY SWITCH AND BOX TOP & STRUT ANGLE HOUSING [76x76x10mm] HEADER RUBBER INDICATOR HEADER [32x32x5mm] 1/4" SOUND DEADENING 1/4" [6mm] OF PENDANT METAL BOLT 1/ [8 2" 9m R m] FACE OF WALL SEE FINISH SCHEDULE FINISH WALL LINE HANGER COVER 4 1/2"± 4'-0" 4 1/2"± [1219mm] [113mm] PLAN 6" (TYP.) BOLTED TO WALL DUST COVER BOLTED TO WALL HANGER RUBBER AS APPROVED BUMPER JAMB BRACKET DOOR CAST HEAD SECTION TOP LANDING 2 LAYERS 5/8" [13mm] GYP. BD. EA. SIDE ANCHOR LINTEL TO CHANNEL WITH 2" [51mm] CLIP ANGLE FIN. JAMB BELOW STOP FINISHED 4'-0" FLOOR [1219mm] BASE OVAL HEAD MACH. PASS. ELEV. 6" 1/4" M.B. [5mm] [6mm] EXTRUDED OR 3/8" [10mm] [2134mm] NON-SLIP SILL 7'-0" LANDINGS TYPICAL NARROW 2"x2"x1/8" [51x51x3mm] 6'-0" KEYWAYS ALL ANGLE REMOVABLE GUIDES [1829mm] HOUSING EMERGENCY STRUT SCREW 12" [64mm] [305mm] O.C. GROUT 5 PR. SILL SOLID BRACKETS OR FIVE Z BARS 1/2" [14mm] M.B. 3/8" [10mm] M.B. ELEVATION OF DOORS NOTES: 1. [305mm] 14 GA. FASCIA [38mm] SILL # TRIM @ HEAD 2. BENT PL. LINTEL ALL METAL GAGES AND FINISHES OF FRAME AND DOORS AS SPECIFIED. PLATE 1 1/2" 3/16" [5mm] CONTINUOUS WELD. E.B. 1" MIN. [25mm] 1 1/2" MAX.[38mm] HEAD AND JAMBS OF FINISHED FRAME SHALL BE SECURED TOGETHER WITH 3/8" [10mm] 1'-0" 3/4" FOR GYP WALLBOARD [152mm] [2134mm] HEADER 19GA. CONC. SHIELD NO. 14 GA. [5mm] DOOR SILL CLIP 2 1/2" MIN. 7'-0" SUB FRAME [19mm] 1/4" [32mm] FIN. FLOOR CLEAR OPENING FASCIA PL. 3/4" CAULK [113mm] WITH STIFFNERS [6mm] 1 1/4" FRAME EA. SIDE [1676mm] SIGHT GUARD 1/4" ANCHORS METAL FRAME 5'-6" FRAME HEAD 4-Z GROUT SOLID CENTERLINE 12 GA [104mm] (5.4#) SUB ASTRAGALS 3 JAMBS AT SILL. 3. SUB FRAME TO BE SUPPLIED AND SET BY ELEVATOR CONTRACTOR. PLAN SECTION @ HEAD ENTRANCE DETAILS - SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR NTS (WITH GYP WALLBD SHAFT HORIZONTAL SLIDING CENTER OPENING DOORS) DETAILS [86mm] CONT. 1 1/4"x1 1/4"x3/16" SECURED TO BENT PLATE LINTEL 3 3/8" ANGLES 4" CHANNEL NEOPRENE ANGLES WELDED TO DETAIL TITLE / ENTRANCE BENT PLATE [51x51mm] CLIP AS REQUIRED SEE PLANS 3/16" [5mm] HANGER COVER WALL VARIES [29mm] CLIP C L OPENING 30° CAULK 2"x2"x12 GA [152mm] 1 1/8" METAL 19GA 9 3/4" 3/16" [5mm] ENDS [19mm] TOP & BOTTOM CLOSED [248mm] [6mm] BUMPER DOOR STOPS [6mm] 1/4" CAD DETAIL NO.: HANGER BELOW 1/4" [6mm] 1/2" 3/16" [5mm] BENT PLATE [25mm] 3"x3"x3/8" CONC. 3/4" [19mm] 1/4" [6mm] DATE ISSUED: DECEMBER 2008 SIDE 1" FACE OF (WITH DRYWALL SHAFT HORIZONTAL SLIDING CENTER OPENING DOORS) ABOVE SIGHT GUARDS SCALE : NONE ANGLE THRESHOLD SERVICE AND PASSENGER ELECTRIC TRACTION OR HYDRAULIC ELEVATOR GYP WALLBD. EA. THRESHOLD NON-SLIP METAL 5"± CONT. TO SILL GUIDE GROOVE [127mm] STRUT METAL [25mm] 1 1/2" [38mm] STIFFENERS; 1" MIN. BOTTOM FLOOR LANDINGS [13mm] PLATE w/ 2 LAYERS SD142100-08.DWG 8'-8" [2642mm] OVER SILL 19 GA. FASCIA 9'-0" [2700mm] B 6'-0" [1800mm] 6'-8" [2000mm] C 5'-8" [1700mm] 6'-8" [2000mm] D 2'-7" [775mm] 3'-5" [1025mm] PLATFORM 9'-3" [2775mm] CLEAR HOISTWAY MIN. CLEAR WELL CASING 8'-8" [2600mm] SEE DETAIL CMU OR METAL STUD COORDINATE WITH ARCHITECTURAL "A" [2400mm] 2 1/4" [56mm] 5" MAX. [125mm] 6 1/2" [162mm] METAL SILL 1 1/4" [30mm] CAR EDGE OF METAL SILL GROUT SOLID PLAN OF ELEVATOR AT BOTTOM FLOOR HOISTWAY WIDTH DIMS. ON PLAN VARIABLE VARIABLE VARIABLE 5" MAX. [125mm] 6 1/2" [162mm] METAL SILL 1 1/4" [30mm] CAR WEATHERPROOF COMPOUND PLUNGER MEMBRANE W.P. ON CYLINDER EXISTING BUILDING CASING AND CYLINDER WITH PACKED DRY SAND O.D. OF CASING SHALL BE MIN. OF 4" [100mm] 2'-0" MIN. THICKNESS, .375" [10mm] FILL SPACE BETWEEN ON EXISTING MEMBRANE W.P. ON BUILDING NEW CONSTRUCTION FIN. PIT FLOOR SOLID 1 1/4" [30mm] 2 1/2" [62mm] [150mm] DETAIL OF WELL CASING AND PLUNGER ASSEMBLY FLOOR 1'-4" [405mm] SLAB DEPRESSION 5" MAX. [125mm] MEMBRANE W.P. ON NEW CONSTRUCTION LARGER THAN CYLINDER 6" CONCRETE BOTTOM HOISTWAY [610mm] STEEL CASING MIN. MEMBRANE W.P. 4'-0" [1200mm] MIN. [75mm] 1/2" x 2 1/2" [240mm x 65mm] GROUT PIT DEPTH 3" MIN. AS REQUIRED 3" MIN. [75mm] SLAB DEPRESSION FOR METAL SILL 9 [2415mm] [1200mm] 2 1/2" [62mm] 7'-11" MIN. CLEAR OPENING [275mm] 2 1/2" [65mm] "D" CONCRETE 11" ELEVATOR TRAVEL 4'-0" 1 1/4" [30mm] 36'-0" [10950mm] "A" FACE OF APPROX. MAX. TRAVEL 5" [125mm] CADD DETAIL NO. : SD142400-01.DWG INSIDE CAR 7'-11" [2415 mm] INSIDE CAR CEILING HT. 8'-0" 8'-2" [2450mm] SECTION "A - A" NONE [300mm] "C" MACHINE ROOM MIN. A SCALE : 12" MIN. ELEVATOR "B" PLATFORM OIL SUPPLY LINE FIRE STOPPED [2268KG] PLAN SECTION HOISTWAY [300mm] WALL TO BE FILLED [1814KG] DETAIL TITLE / HYDRAULIC "A" CLEAR 9'-0" CLEAR MACH. RM. 12" MIN PIPE SLEEVE THRU 5000 LB. CAP. 2 1/2" [65mm] [200mm] [2700mm] 4000 LB. CAP. [100mm] 14'-0" [4250mm] 4" MIN. 8" MIN. ROOF OR PENTHOUSE DATE ISSUED :DECEMBER 2008 VARIABLE CAR DIMENSIONS