2 4 LIGHTING FIXTURES SWITCHES AND CONTROLS DISTRIBUTION EQUIPMENT (EQUIPMENT PREFIX) SUBSCRIPTS: A1b = TYPE A, CIRCUIT 1, CONTROL ZONE b SUBSCRIPTS: 3b = TYPE 3, CONTROL ZONE b LIGHTING OR RECEPTACLE PANELBOARD TOGGLE SWITCH: 3 = 3-WAY, 2 = DOUBLE POLE, 4 = 4 WAY, DM = DIMMER, K = KEY OPERATED, EX = EXPLOSION PROOF, T = TIMER OPERATED, LM = LOW VOLTAGE MASTER, OC = OCCUPANCY SENSOR SWITCH, F = FUSED, M = MANUAL MOTOR STARTER, CB = CIRCUIT BREAKER RELAY CABINET 3 CEILING OR PENDANT INCANDESCENT, HID OR COMPACT FLUORESCENT CEILING OR PENDANT INCANDESCENT, HID OR COMPACT FLUORESCENT EMERGENCY LIGHT CEILING OR PENDANT HID WITH QUARTZ RESTRIKE 10 FLUORESCENT STRIP LIGHT DISTRIBUTION OR POWER PANELBOARD MOTOR CONTROL CENTER SWITCHBOARD DIMMER, 6 = 600W, 10 = 1000W WALL MOUNTED INCANDESCENT, HID OR COMPACT FLUORESCENT D 3 M OCCUPANCY SENSOR, WALL MOUNTED OR CEILING MOUNTED, DIRECTIONAL M OCCUPANCY SENSOR, CEILING MOUNTED, MULTI DIRECTIONAL TIME CLOCK PUSHBUTTON OR CONTROL STATION CONTACTOR RACEWAYS AND WIRES 4. FOR EXACT LOCATIONS OF RECESSED LIGHTING FIXTURES, REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH LOCATION OF EQUIPMENT, PIPING AND DUCTWORK. CONDUIT OR CABLE BELOW SLAB, IN SLAB OR UNDERGROUND CONDUIT OR CABLE TURNING UP 0 MOTOR STARTER, 0 = STARTER SIZE FLOODLIGHT 30 (12) 0 COMBINATION MOTOR STARTER AND DISCONNECT SWITCH 30 = SWITCH AMPERE RATING (12) = FUSE AMPERE RATING 0 = STARTER SIZE 100 (70) 1 COMBINATION MOTOR STARTER AND CIRCUIT PROTECTOR 100 = FRAME SIZE (70) = TRIP RATING 1 = STARTER SIZE 30 (15) FUSED DISCONNECT SWITCH 30 = SWITCH AMPERE RATING (15) = FUSE AMPERE RATING OUTLET BOX WITH BLANK COVER NON-FUSED DISCONNECT SWITCH 30 = SWITCH AMPERE RATING JUNCTION BOX, FLOOR DUCT SYSTEM ROADWAY OR PARKING LOT STANDARD POST TOP WALKWAY OR PARKING LOT STANDARD BUILDING MOUNTED WALLPACK IN POOL WET NICHE LIGHT LIGHTING TRACK WITH FIXTURES 30 DOCK LIGHT CONDUIT CAPPED WALL MOUNTED EXIT SIGN TELEPHONE TERMINAL BOARD (TB) SHADING INDICATES ILLUMINATED FACE OF EXIT SIGN TELEPHONE TERMINAL CABINET (TC) ARROW INDICATES EXIT SIGN DIRECTIONAL ARROW TELEPHONE WALL OUTLET, W = WALL, P = PUBLIC, F = FIRE FIGHTER, WP = WEATHERPROOF #10,3/4" JUNCTION BOX PULL BOX FCP FIRE ALARM CONTROL PANEL LOC LOCAL OPERATING CONSOLE FSA FIRE ALARM SYSTEM ANNUNCIATOR NAC NAC EXTENDER PANEL (REMOTE POWER SUPPLY) FTP FIRE ALARM TRANSPONDER PANEL TELEPHONE FLOOR OUTLET OR SERVICE FITTING SPECIAL RECEPTACLE, X = NEMA DESIGNATION B PUBLIC ADDRESS PUSHBUTTON DUPLEX FLOOR RECEPTACLE VOLUME CONTROL AND CHANNEL SELECTOR SINGLE FLOOR RECEPTACLE CEILING MOUNTED SPEAKER, S=SOUND MASKING DUPLEX RECEPTACLE AND DATA OUTLET IN FLOOR BOX OR SERVICE FITTING I E U SPECIAL FLOOR RECEPTACLE DUPLEX RECEPTACLE AND TELEPHONE OUTLET IN FLOOR BOX OR SERVICE FITTING P WALL MOUNTED SPEAKER S MASTER CLOCK (CM) C C C P C EOL 75 DOUBLE FACE CLOCK, A = ANALOG, D = DIGITAL F 75 PROGRAM BELL M 75 PROGRAM BUZZER POKE-THROUGH WITH DUPLEX RECEPTACLE AND FOUR CATEGORY 5 COMMUNICATION JACKS BUZZER SWITCH OFF AIR ANTENNA TV 75 M PARTITION SENSOR, 10= 1000, 6=600 75 F A LEGEND ABBREVIATIONS FA FLOUR FIRE ALARM FLOURESCENT G GFCI GROUND GROUND FAULT CIRCUIT INTERUPTER INCND INCANDESCENT ELEVATOR RECALL PHOTOELECTRIC SMOKE DETECTOR LTG LIGHTING DUCT SMOKE DETECTOR MECH MIN MTD MECHANICAL MINIMUM MOUNTED N NIC NP NEUTRAL NIT IN CONTRACT NOT PERMITTED WALL-MOUNTED MASS NOTIFICATION STROBE (AMBER) (NUMBER INDICATES CANDELA RATING) EXP = EXPLOSION PROOF PC PWR PERSONAL COMPUTER POWER WALL-MOUNTED SPEAKER/STROBE (CLEAR) (NUMBER INDICATES CANDELA RATING) EXP = EXPLOSION PROOF QTY QUANTITY RECP REQD RM RECEPTACLE REQUIRED ROOM SC SS SW SPLIT CIRCUIT SINGLE STATION SMOKE ALARM SWITCH TEL TELCOM TYP TELEPHONE TELECOMMUNICATIONS TYPICAL UPS UNINTERUPTABLE POWER SUPPLY WP WEATHER PROOF XFRMR TRANSFORMER PHOTOELECTRIC SMOKE DETECTOR IONIZATION SMOKE DETECTOR SUB FLOOR SMOKE DETECTOR END OF LINE DEVICE WALL-MOUNTED FIRE ALARMSTROBE (CLEAR) (NUMBER INDICATES CANDELA RATING) EXP = EXPLOSION PROOF WALL-MOUNTED FIRE ALARM SPEAKER F TELEVISION OUTLET 10 11. ALL EMERGENCY LIGHT FIXTURES SHALL BE UNSWITCHED SO AS TO BE UTILIZED AS NIGHT LIGHTS. ELECTRICAL ELEVATION EMERGENCY SINGLE FACE CLOCK, A = ANALOG, D = DIGITAL PROGRAM CLOCK WITH INTERCOM DUPLEX RECEPTACLE, TELEPHONE AND DATA OUTLET IN FLOOR BOX OR SERVICE FITTING 10. SIZE OUTLET AND JUNCTION BOXES PER 2005 NEC ARTICLE 314, UNLESS OTHERWISE NOTED. ELEC ELEV EMER MANUAL PULL STATION MICROPHONE OUTLET DUPLEX CEILING RECEPTACLE DOUBLE DUPLEX FLOOR RECEPTACLE F EQUIPMENT RACK M 9. CONDUITS ARE 3/4", UNLESS OTHERWISE NOTED. DIGITAL ALARM COMMUNICATOR TRANSMITTER 195 RATE OF RISE HEAT DETECTOR R 195 FIXED TEMPERATURE HEAT DETECTOR F MISCELLANEOUS SYSTEMS CLOCK RECEPTACLE WITH HANGER 8. WIRES ARE #12, UNLESS OTHERWISE NOTED. ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ARCHITECTURAL AVERAGE LCD ANNUNCIATOR LCD COMBINATION TELEPHONE IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET DATA CEILING OUTLET DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT DACT COMBINATION TELEPHONE AND DATA WALL OUTLET, 2 = 2-PORT, 4 = 4-PORT, EXP = EXPLOSION PROOF, M = MODULAR SINGLE RECEPTACLE X DATA OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET 4'-0" LIGHTING SWITCHES 1'-6" GENERAL PURPOSE RECEPTACLES COUNTER TOP RECEPTACLES 8 INCHES ABOVE COUNTER 1'-6" TELEPHONE OUTLETS 1'-6" DATA OUTLETS 1'-6" TELEVISION OUTLET (COAX) AFF AFG ARCH AVG DATA WALL OUTLET, D = DATA, F = FAX, S=SIPRNET 4 By: Description: 7. MOUNTING HEIGHTS ABOVE FINISHED FLOOR ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: FIRE ALARM & MASS NOTIFICATION SYSTEM LEGEND RECEPTACLES SUBSCRIPTS: 1b = CIRCUIT 1, CONTROL ZONE b GFCI = GROUND FAULT CIRCUIT INTERRUPTER WP = WEATHERPROOF WHILE IN USE COVER S = SWITCHED, F = FLUSH FLOOR, SM = SURFACE MOUNT FLOOR DUPLEX RECEPTACLE Revision: Date: 6. MOUNTING HEIGHTS FOR WALL MOUNTED FIXTURES OR DEVICES ARE TO CENTER LINE OF OUTLET BOXES, UNLESS OTHERWISE NOTED. WIRING: LONG SLASH = NEUTRAL (N) SHORT SLASH = HOT SHORT SLASH WITH HOOK = SWITCHED LONG SLASH WITH DOT = GROUND (G) #10 = WIRE SIZE 3/4" = CONDUIT SIZE C TELEPHONE AND DATA COMMUNICATIONS 501 North Broadway, St. Louis, Missouri 63102-2121 5. MOUNTING HEIGHTS FOR CEILING MOUNTED FIXTURES OR DEVICES ARE TO BOTTOM OF FIXTURES OR DEVICES, UNLESS OTHERWISE NOTED. LP1-2,4,6 HOMERUN, LP1 = PANEL DESTINATION, 2,4,6 = CIRCUITS STEP OR AISLE LIGHT CEILING OR PENDANT MOUNTED EXIT SIGN NOT FOR CONSTRUCTION CONDUIT OR CABLE TURNING DOWN REMOTE EMERGENCY HEAD SPOTLIGHT, ARROW INDICATES DIRECTION OF AIM 2. LIGHTING CONTROL ZONE DESIGNATIONS INDICATE WHICH DEVICES CONTROL WHICH GROUPS OF FIXTURES. WHERE LOCAL SWITCHES AND DIMMERS ARE SHOWN, OR WHERE NO CONTROL ZONE DESIGNATION IS INDICATED, LOCAL CONTROL DEVICES SHALL ONLY CONTROL FIXTURES IN THEIR RESPECTIVE ROOMS. 3. SIZE OUTLET AND JUNCTION BOXES PER 2005 NEC ARTICLE 314, UNLESS OTHERWISE NOTED. CONDUIT OR CABLE BELOW RAISED FLOOR FLUORESCENT EMERGENCY LIGHT BATTERY PACK WITH HEADS 1. ALL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT. TRANSFORMER CONDUIT OR CABLE (RUN AS INDICATED) FLUORESCENT PHOTOCELL ELECTRICAL GENERAL NOTES 911 Central Parkway N., Suite 425 San Antonio, TX 78323 FLUORESCENT STRIP EMERGENCY LIGHT FLUORESCENT WITH ASYMMETRICAL DISTRIBUTION LINE REPRESENTS LAMP AXIS 5 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES 1 CEILING-MOUNTED MASS NOTIFICATION STROBE (AMBER) (NUMBER INDICATES CANDELA RATING) CEILING-MOUNTED SPEAKER/STROBE (CLEAR) (NUMBER INDICATES CANDELA RATING) M MINI-SPEAKER FS SPRINKLER FLOW SWITCH TS SPRINKLER TAMPER SWITCH AIM ADDRESSABLE INTERFACE MODULE ACM ADDRESSABLE CONTROL MODULE DOOR HOLD AND RELEASE DEVICE Scales: NOT TO SCALE Jacobs Project No.: FDWD1301 Drawing Title: NOTES AND SYMBOLS N Date: May 11, 2009 Designed By: Designer Drawn By: SBW Checked By: Checker Drawing No.: E-001 1 3 2 4 5 42 W 25 W 18 W 18 W 18 W 25 W 42TRT T8 18DTT 18DTT -T8 120 V 120 V 120 V 120 V 120 V 120 V NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 MANUFACTURER LITHONIA LITHONIA LITHONIA LITHONIA -LITHONIA FIXTURE CATALOG NUMBER WST 42TRT MDU 120 ELDWC PE LPI WP 2 25 MVOLT S2 BF GEB10PS 2/1 LF6 2/18DTT F602A 120 GEB10 LF6 2/18DTT F602A 120 GEB10 EL -SM 1 25 MVOLT ES GEB10RS REMARKS 501 North Broadway, St. Louis, Missouri 63102-2121 Revision: Date: By: Description: AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES 1 2 2 2 3 1 LAMP TYPE FIXTURE VA 40 VA 40 VA 30 VA 30 VA 50 VA 20 VA FIXTURE INPUT VOLTAGE LAMP WATTAGE FIXTURE DESCRIPTION Exterior Wall OUTDOOR WALL LIGHT WITH EMERGENCY BALLAST SURFACE Bathroom Wall WALL LIGHT SURFACE Ceiling CAN LIGHT RECESSED Emergency Ceiling CAN LIGHT WITH EMERGENCY BALLAST RECESSED Ceiling Fan CEILING FAN SURFACE Mech/Laundry Wall WALL LIGHT SURFACE LAMP QUANTITY MOUNTING D Type Mark A C D D F G TYPE LIGHTING FIXTURE SCHEDULE C B Scales: Jacobs Project No.: A FDWD1301 Drawing Title: LIGHTING SCHEDULE Date: May 11, 2009 Designed By: Designer Drawn By: Author Checked By: Checker Drawing No.: E-501 1 3 2 4 5 KEYED NOTES Panel PP-A Voltage 120 V / 208 V Phase Three Phase Mount TBD D 2 C 2 LIGHTING - WEST LIGHTING - EAST SPARE SPARE KITCHEN 113 REFRIGERATOR KITCHEN 113 COUNTER TOP REC KITCHEN 113 - 1/2HP DISPOSER KITCHEN 113 DISHWASHER KITCHEN 113 MICROWAVE KITCHEN 113 COUNTER TOP REC Trip 15 A Enclosure Type 1 Poles 1 Ckt. No. 1 1 1 3 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 15 A 15 A 15 A 15 A 1 1 1 1 1 15 A 1 33 20 A 1 35 15 A 1 37 20 A 1 39 15 A 1 41 1 B C Ckt. No. 2 Poles 2 2 Trip 60 A THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER. LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO 1500VA PER NEC 220.52. NOT FOR CONSTRUCTION Load Name KITCHEN 113 - RANGE 7 1 720 VA / 2880 VA 9 1 540 VA / 2880 VA 11 1 13 1 540 VA / 960 VA 19 1 540 VA / 696 VA 1 23 25 27 29 31 20 A 8 2 30 A 12 LAUNDRY 104 WASHER LAUNDRY 104 - DRYER 2 20 A HVAC CENTRAL (1HP) 1 15 A 1 15 A 1 15 A 1 15 A 24 26 28 30 32 1 1 1 1 1 15 A 15 A 15 A 15 A 15 A HVAC - BEDROOM 101 (1/4HP) HVAC - BEDROOM 108 (1/4HP) HVAC - BEDROOM 111 (1/4HP) HVAC - BEDROOM 116 (1/4HP) SPARE SPARE SPARE SPARE SPARE 34 1 15 A SPARE 36 1 15 A SPARE 38 1 15 A SPARE 40 1 15 A SPARE 42 1 15 A SPARE 16 360 VA / 696 VA 360 VA / 696 VA 21 1 1 2 Revision: Date: By: Description: 14 17 1 6 10 540 VA / 960 VA 15 1 501 North Broadway, St. Louis, Missouri 63102-2121 4 720 VA / 1500 VA 18 20 1260 VA / 696 VA 22 450 VA / 0 VA 460 VA / 0 VA 1500 VA / 0 VA 180 VA / 0 VA 1176 VA / 0 VA 744 VA / 0 VA 1500 VA / 0 VA 180 VA / 0 VA Phase B 14772 VA Mfg. / Type -- Location TBD 720 VA / 5760 VA 5 1 1 A 720 VA / 5760 VA 1 MCB 911 Central Parkway N., Suite 425 San Antonio, TX 78323 15 A Phase A 15340 VA Mains 200 A Phase C 6582 VA Modifications -- 1 1 1 1 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES Load Name BEDROOM 101 - DESK AND CONV REC BEDROOM 101 - CONV REC BEDROOM 108 - DESK AND CONV REC BEDROOM 108 - CONV REC BEDROOM 111 - DESK AND CONV REC BEDROOM 111 - CONV REC BEDROOM 116 - DESK AND CONV REC BEDROOM 116 - CONV REC BATHROOMS 102, 109 CONV REC BATHROOMS 106, 115 CONV REC LIVING 112 - REC Wires 4 Wires Total VA 36694 VA Amps RMS. Sym. -- B Scales: Jacobs Project No.: A FDWD1301 Drawing Title: PANEL SCHEDULE A Date: May 11, 2009 Designed By: Designer Drawn By: Author Checked By: Checker Drawing No.: E-502 1 3 2 4 5 KEYED NOTES Panel PP-B Voltage 120 V / 208 V Phase Three Phase Mount TBD D 2 C 2 LIGHTING - NORTH LIGHTING - SOUTH SPARE SPARE KITCHEN 126 REFRIGERATOR KITCHEN 126 COUNTER TOP REC KITCHEN 126 DISHWASHER KITCHEN 126 DISPOSAL (1/2HP) KITCHEN 126 MICROWAVE KITCHEN 126 COUNTER TOP REC Trip 15 A Enclosure Type 1 Poles 1 Ckt. No. 1 1 1 3 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 15 A 15 A 15 A 15 A 1 1 1 1 1 15 A 1 33 15 A 1 35 20 A 1 37 20 A 1 39 15 A 1 41 1 B C Ckt. No. 2 Poles 2 2 Trip 60 A THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER. LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO 1500VA PER NEC 220.52. NOT FOR CONSTRUCTION Load Name KITCHEN 126 - RANGE 7 1 720 VA / 2880 VA 9 1 540 VA / 2880 VA 11 1 13 1 540 VA / 960 VA 19 1 720 VA / 696 VA 1 23 25 27 29 31 1 20 A 8 2 30 A 12 LAUNDRY 124 WASHER LAUNDRY 124 - DRYER 2 20 A HVAC - CENTRAL (1HP) 1 15 A 1 15 A 1 15 A 1 15 A 24 26 28 30 32 1 1 1 1 1 15 A 15 A 15 A 15 A 15 A HVAC - BEDROOM 117 (1/4HP) HVAC - BEDROOM 127 (1/4HP) HVAC - BEDROOM 122 (1/4HP) HVAC - BEDROOM 132 (1/4HP) SPARE SPARE SPARE SPARE SPARE 34 1 15 A SPARE 36 1 15 A SPARE 38 1 15 A SPARE 40 1 15 A SPARE 42 1 15 A SPARE 16 360 VA / 696 VA 360 VA / 696 VA 21 1 6 2 Revision: Date: By: Description: 14 17 1 501 North Broadway, St. Louis, Missouri 63102-2121 10 720 VA / 960 VA 15 1 4 540 VA / 1500 VA 18 20 1440 VA / 696 VA 22 410 VA / 0 VA 440 VA / 0 VA 1500 VA / 0 VA 180 VA / 0 VA 744 VA / 0 VA 1176 VA / 0 VA 1500 VA / 0 VA 180 VA / 0 VA Phase B 15132 VA Mfg. / Type -- 1 Location TBD 720 VA / 5760 VA 5 1 1 A 540 VA / 5760 VA MCB 911 Central Parkway N., Suite 425 San Antonio, TX 78323 15 A Phase A 15572 VA Mains 200 A Phase C 6110 VA Modifications -- 1 1 1 1 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES Load Name BEDROOM 117 - DESK AND CONV REC BEDROOM 117 - CONV REC BEDROOM 127 - DESK AND CONV REC BEDROOM 127 - CONV REC BEDROOM 122 - DESK AND CONV REC BEDROOM 122 - CONV REC BEDROOM 132 - DESK AND CONV REC BEDROOM 132 - CONV REC BATHROOMS 118, 120 CONV REC BATHROOMS 129, 131 CONV REC LIVING 125 - REC Wires 4 Wires Total VA 36814 VA Amps RMS. Sym. -- B Scales: Jacobs Project No.: A FDWD1301 Drawing Title: PANEL SCHEDULE B Date: May 11, 2009 Designed By: Designer Drawn By: Author Checked By: Checker Drawing No.: E-503 1 3 2 4 5 KEYED NOTES Voltage 120 V / 208 V Phase Three Phase Mount TBD Load Name BEDROOM 133 - DESK AND CONV REC BEDROOM 133 - CONV REC BEDROOM 144 - DESK AND CONV REC BEDROOM 144 - CONV REC BEDROOM 136 - DESK AND CONV REC BEDROOM 136 - CONV REC BEDROOM 140 - DESK AND CONV REC BEDROOM 140 - CONV REC BATHROOMS 134, 138 CONV REC BATHROOMS 143, 139 CONV REC LIVING 145 - REC D 2 C 2 LIVING 145 - REC LIGHTING - EAST LIGHTING - WEST SPARE KITCHEN 146 REFRIGERATOR KITCHEN 146 COUNTER TOP REC KITCHEN 146 DISPOSAL (1/2HP) KITCHEN 146 DISHWASHER KITCHEN 146 COUNTER TOP REC KITCHEN 146 MICROWAVE Trip 15 A Wires 4 Wires Mains 200 A MCB Enclosure Type 1 Poles 1 Ckt. No. 1 A 540 VA / 5760 VA B 1 Location 2 TBD C Ckt. No. 2 Poles 2 Trip 60 A Load Name KITCHEN 146 - RANGE 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 1 15 A 15 A 15 A 15 A 15 A 1 1 1 1 1 15 A 1 33 20 A 1 35 15 A 1 37 15 A 1 39 20 A 1 41 Phase A 15350 VA 3 1 720 VA / 5760 VA 5 1 7 1 720 VA / 2880 VA 9 1 720 VA / 2880 VA 11 1 13 1 19 1 1 1 1 23 25 27 29 31 8 2 30 A LAUNDRY 147 WASHER LAUNDRY 147 - DRYER 2 Revision: Date: HVAC - CENTRAL (1HP) 12 1 15 A 1 15 A 1 15 A 1 15 A 440 VA / 0 VA 24 26 28 30 32 1 1 1 1 1 15 A 15 A 15 A 15 A 15 A HVAC - BEDROOM 133 (1/4HP) HVAC - BEDROOM 144 (1/4HP) HVAC - BEDROOM 136 (1/4HP) HVAC - BEDROOM 140 (1/4HP) SPARE SPARE SPARE SPARE SPARE 180 VA / 0 VA 34 1 15 A SPARE 36 1 15 A SPARE 38 1 15 A SPARE 40 1 15 A SPARE 42 1 15 A SPARE By: Description: 14 720 VA / 696 VA 16 360 VA / 696 VA 360 VA / 696 VA 18 20 900 VA / 696 VA 22 1080 VA / 0 VA 470 VA / 0 VA 1500 VA / 0 VA 1176 VA / 0 VA 744 VA / 0 VA 180 VA / 0 VA 1500 VA / 0 VA Phase B 13892 VA Mfg. / Type -- 20 A 20 A 720 VA / 960 VA 21 1 1 2 17 1 6 10 720 VA / 960 VA 15 1 501 North Broadway, St. Louis, Missouri 63102-2121 4 540 VA / 1500 VA LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO 1500VA PER NEC 220.52. NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 1 15 A THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER. Phase C 8532 VA Modifications -- 1 1 1 1 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES Panel PP-C Total VA 37774 VA Amps RMS. Sym. -- B Scales: Jacobs Project No.: A FDWD1301 Drawing Title: PANEL SCHEDULE C Date: May 11, 2009 Designed By: Designer Drawn By: Author Checked By: Checker Drawing No.: E-504 1 3 2 4 5 GENERAL NOTES 1. CEILING MOUNTED LIGHT FIXTURES ARE MOUNTED AT 102" AFF. 2. WALL MOUNTED LIGHT FIXTURES IN BATHROOMS ARE COORDINATED TO BE MOUNTED ABOVE THE WALL MIRROR. NOT FOR CONSTRUCTION A BEDROOM BEDROOM MECH. 117 127 123 G 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 D LAUNDRY F F 124 G CLOSET CLOSET 119 128 Revision: Date: D BATHROOM By: Description: BATHROOM KITCHEN 118 126 D D 129 D D C C 23 D F 25 C BATHROOM C 120 D D 131 CLOSET CLOSET 121 130 C BATHROOM D D AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES D D F F LIVING 125 BEDROOM BEDROOM 122 C1 132 PLAN B LIGHTING PLAN 1/4" = 1'-0" C3 BATHROOM 102 BATHROOM A 106 C BEDROOM C G MECH. 101 CLOSET B PLAN B LIGHTING AXON D 105 103 BEDROOM 108 CLOSET D 107 LAUNDRY D 104 F F G D D CLOSET CLOSET D 110 D 114 F BATHROOM BATHROOM LIVING 109 112 D D 115 D D C C D KITCHEN 113 D Scales: D 1/4" = 1'-0" Jacobs Project No.: A F Drawing Title: F BEDROOM BEDROOM 111 116 LIGHTING PLANS/AXON N 23 PLAN A LIGHTING PLAN A1 1/4" = 1'-0" FDWD1301 25 A3 PLAN A LIGHTING AXON Date: May 11, 2009 Designed By: Designer Drawn By: SBW Checked By: Checker Drawing No.: EL101 1 3 2 4 5 GENERAL NOTES 1. CEILING MOUNTED LIGHT FIXTURES ARE MOUNTED AT 102" AFF. 2. WALL MOUNTED LIGHT FIXTURES IN BATHROOMS ARE COORDINATED TO BE MOUNTED ABOVE THE WALL MIRROR. NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 D Revision: Date: AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES C LAUNDRY 147 KITCHEN G 146 MECH. G 148 A D BEDROOM LIVING BEDROOM 133 145 144 B F F F BATHROOM BATHROOM 134 143 D C CLOSET CLOSET 137 141 D CLOSET D D 135 D D CLOSET C 142 D D D C Scales: C F Jacobs Project No.: BEDROOM 136 D BATHROOM 138 140 D 27 25 FDWD1301 Drawing Title: LIGHTING PLANS/AXON BATHROOM 139 N PLAN C LIGHTING PLAN A1 1/4" = 1'-0" 1/4" = 1'-0" F BEDROOM A By: Description: A3 PLAN C LIGHTING AXON Date: May 11, 2009 Designed By: Designer Drawn By: SBW Checked By: Checker Drawing No.: EL102 1 3 2 4 5 GENERAL NOTES 1. RECEPTACLES ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. GFCI RECEPTACLES ARE MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED. MECH. 123 2. ALL RECEPTACLES SHALL BE ARC-FAULT CIRCUIT INTERUPTER TYPE EXCEPT WHEN LOCATED IN KITCHENS, BATHROOMS, AND OUTDOORS. 6 NOT FOR CONSTRUCTION 8,10 D 911 Central Parkway N., Suite 425 San Antonio, TX 78323 7 3 BEDROOM BEDROOM 117 127 501 North Broadway, St. Louis, Missouri 63102-2121 21 5 1 LAUNDRY 124 31 17 (SC) BATHROOM 118 CLOSET 33 121 9 By: Description: 19 (SC) 129 35 39 MICROWAVE 2,4 84" AFF CLOSET BATHROOM 128 37 DISPOSER DISHWASHER 120 41 CLOSET REFRIGERATOR 119 BATHROOM Revision: Date: CLOSET BATHROOM 130 131 RANGE 13 11 15 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES LIVING 125 C C1 BEDROOM BEDROOM 122 132 PLAN B POWER PLAN 1/4" = 1'-0" C3 17 (SC) MECH. 8,10 6 PLAN B POWER AXON 19 (SC) 105 21 BATHROOM BATHROOM 102 106 B BEDROOM BEDROOM CLOSET 101 LAUNDRY 103 3 17 (SC) 109 108 107 104 1 BATHROOM CLOSET 5 7 CLOSET CLOSET 110 114 BATHROOM 115 LIVING 19 (SC) 112 11 DISHWASHER KITCHEN 33 2,4 15 41 113 Scales: 39 BEDROOM 111 BEDROOM 9 DISPOSER 35 31 RANGE MICROWAVE 84" AFF REFRIGERATOR Jacobs Project No.: 116 37 A FDWD1301 Drawing Title: 13 POWER PLANS/AXON N PLAN A POWER PLAN A1 1/4" = 1'-0" 1/4" = 1'-0" A3 PLAN A POWER AXON Date: May 11, 2009 Designed By: Designer Drawn By: SBW Checked By: Checker Drawing No.: EP101 1 3 2 4 5 GENERAL NOTES 1. RECEPTACLES ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. GFCI RECEPTACLES ARE MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED. 2. ALL RECEPTACLES SHALL BE ARC-FAULT CIRCUIT INTERUPTER TYPE EXCEPT WHEN LOCATED IN KITCHENS, BATHROOMS, AND OUTDOORS. NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 D Revision: Date: AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR DORMITORIES C 41 2,4 RANGE MICROWAVE 84" AFF 35 31 6 8,10 MECH. KITCHEN LAUNDRY 147 146 DISPOSER 148 REFRIGERATOR 39 DISHWASHER 1 23 5 37 33 LIVING 145 B BEDROOM 133 7 3 By: Description: BEDROOM 144 21 BATHROOM 134 17(SC) CLOSET CLOSET CLOSET 137 141 CLOSET 135 19(SC) BATHROOM 143 142 15 11 Scales: 9 BEDROOM 136 13 17 (SC) 19 (SC) 1/4" = 1'-0" BEDROOM 140 Jacobs Project No.: A FDWD1301 Drawing Title: BATHROOM BATHROOM 138 139 POWER PLANS/AXON N A1 PLAN C POWER PLAN 1/4" = 1'-0" 1 PLAN C POWER AXON Date: May 11, 2009 Designed By: Designer Drawn By: SBW Checked By: Checker Drawing No.: EP102