Document 12118653

advertisement
1
112
NOT FOR
CONSTRUCTION
BATHROOM
106
35 SF
MECH.
105
10 SF
102
911 Central Parkway N., Suite 425 San Antonio, TX 78323
106
D
A07
10
CLOSET
107
20 SF
22
A07
EQ
501 North Broadway, St. Louis, Missouri 63102-2121
BEDROOM
108
129 SF
23
9
21
103
5
105
BATHROOM
102
35 SF
CLOSET
103
20 SF
4
104
EQ
101
BATHROOM
109
35 SF
107
LAUNDRY
104
10 SF
108
Revision:
Date:
BATHROOM
115
35 SF
3
03
19
2
3
2
A07
A08
20
LIVING
112
4 179 SF
1
A07
4
18
1
CLOSET
110
20 SF
110
109
114
CLOSET
114
20 SF
116
KITCHEN
113
38 SF
111
BEDROOM
111
129 SF
115
REF.
BEDROOM
116
129 SF
7
6
A07
03
8
5
C
01
1
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
BEDROOM
101
129 SF
3
2
02
01
01
02
01
UNIT A
1/4" = 1'-0"
3
01
02
01
01
MECH.
123
10 SF
123
02
UNIT A
01
BEDROOM
127
129 SF
125
13
12
A07
BEDROOM
117
14 129 SF
124
LAUNDRY
124
10 SF
11
B
A07
127
128
BATHROOM
129
35 SF
129
REF.
CLOSET
119
19 SF
26
25
CLOSET
128
19 SF
117
BATHROOM
118
35 SF
118
119
27
24
7
6
A08
8
5
120
121
BATHROOM
120
35 SF
KITCHEN
126
40 SF
130
CLOSET
130
19 SF
122
131
BATHROOM
131
35 SF
132
Scales:
BEDROOM
122
129 SF
LIVING
125
226 SF
6'-0"
CLOSET
121
19 SF
1/4" = 1'-0"
BEDROOM
132
129 SF
FDWD1301
Jacobs Project No.:
A
Drawing Title:
PLANS/ AXON
01
2
UNIT B
1/4" = 1'-0"
02
01
01
02
01
4
UNIT B
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A01
1
3
2
NOT FOR
CONSTRUCTION
148
147
LAUNDRY
147
10 SF
03
5
MECH.
148
12 SF
REF.
KITCHEN
146
47 SF
4
145
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
LIVING
145
173 SF
01
01
A07
01
11
17
02
10
15
BEDROOM
133
129 SF
A08
02
12
BEDROOM
144
129 SF
9
133
BATHROOM
134
35 SF
134
142
30
A07
CLOSET
141
20 SF
31
137
CLOSET
135
20 SF
CLOSET
142
20 SF
143
BATHROOM
143
35 SF
141
136
140
BEDROOM
136
129 SF
BEDROOM
140
129 SF
C
138
02
139
BATHROOM
138
35 SF
01
02
BATHROOM
139
35 SF
01
1
01
CLOSET
137
20 SF
28
01
01
UNIT C.1
1/4" = 1'-0"
2
KITCHEN
293
35 SF
UNIT C.1
MECH.
292
10 SF
REF.
292
291
LAUNDRY
291
10 SF
03
179
B
01
01
02
02
01
BEDROOM
182
129 SF
BATHROOM
183
35 SF
183
By: Description:
144
135
29
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
16
BEDROOM
173
129 SF
LIVING
179
183 SF
182
01
173
185
175
CLOSET
178
20 SF
CLOSET
175
20 SF
174
BATHROOM
174
35 SF
CLOSET
186
20 SF
186
CLOSET
185
20 SF
01
A
02
Scales:
181
BEDROOM
172
129 SF
180
171
01
UNIT C.2
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
Drawing Title:
02
BATHROOM
171
35 SF
PLANS/ AXON
01
N
3
1/4" = 1'-0"
172
BEDROOM
181
129 SF
BATHROOM
180
35 SF
01
176
4
UNIT C.2
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A02
1
3
2
LAUNDRY
443
10 SF
01
212
213
4
5
NOT FOR
CONSTRUCTION
MECH.
444
10 SF
LIVING
436
116 SF
02
214
01
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
REF.
501 North Broadway, St. Louis, Missouri 63102-2121
01
01
KITCHEN
445
69 SF
02
01
Revision:
Date:
02
BEDROOM
439
129 SF
BATHROOM
440
35 SF
206
BEDROOM
432
129 SF
204
By: Description:
01
211
205
201
CLOSET
435
20 SF
CLOSET
434
20 SF
202
BATHROOM
433
35 SF
CLOSET
442
20 SF
209
01
C
02
203
207
199
BEDROOM
438
129 SF
BEDROOM
431
129 SF
208
210
BATHROOM
437
35 SF
02
BATHROOM
430
35 SF
01
1
01
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
CLOSET
441
20 SF
01
UNIT C.3
1/4" = 1'-0"
2
UNIT C.3
B
UP
Scales:
3
A
STAIRS
1/4" = 1'-0"
4
STAIRS
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
Drawing Title:
PLANS/ AXON
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A03
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
BULK STORAGE
297
1197 SF
305A
B
MULTI-PURPOSE AREA
305
272 SF
296
305B
By: Description:
VENDING
307
25 SF
297
SUPPLY STORAGE ROOM
295
100 SF
PUBLIC TOILET
296
100 SF
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
1
COMMON AREA
1/4" = 1'-0"
2
COMMON AREA
Drawing Title:
PLANS/ AXON
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A04
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
SS
SS
Revision:
Date:
By: Description:
SS
SS
SS
SS
SS
C
1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
SS
SS
SS
UNIT A
1/4" = 1'-0"
3
UNIT C.1
1/4" = 1'-0"
8'-6"
8'-6"
SS
SS
B
8'-6"
8'-6"
SS
SS
SS
8'-6"
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
2
REFLICTIVE CEILING
PLANS
UNIT B
1/4" = 1'-0"
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A05
1
3
2
4
LEVEL 2
12'-0"
5
LEVEL 2
12'-0"
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
LEVEL 1
0'-0"
C
3
5
Revision:
Date:
UNIT A EAST
2
1/4" = 1'-0"
UNIT A NORTH
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
4
UNIT A WEST
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
UNIT B SOUTH
1/4" = 1'-0"
6
UNIT B NORTH
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
B
7
UNIT C EAST
1/4" = 1'-0"
8
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
UNIT A SOUTH
1
1/4" = 1'-0"
LEVEL 1
0'-0"
UNIT C WEST
1/4" = 1'-0"
LEVEL 2
12'-0"
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
BUILDING
ELEVATIONS
LEVEL 1
0'-0"
N
9
UNIT C NORTH
1/4" = 1'-0"
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A06
1
3
2
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
4
LEVEL 2
12'-0"
5
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
1
8
BATH 01 - A
1/4" = 1'-0"
LEVEL 1
0'-0"
2
LEVEL 1
0'-0"
BATH 01 - B
1/4" = 1'-0"
3
LEVEL 1
0'-0"
BATH 01 - C
1/4" = 1'-0"
4
LEVEL 1
0'-0"
BATH 01 - D
1/4" = 1'-0"
5
BR 01 - A
1/4" = 1'-0"
LEVEL 1
0'-0"
6
BR 01 - B
1/4" = 1'-0"
LEVEL 1
0'-0"
7
BR 01 - C
1/4" = 1'-0"
Revision:
Date:
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
BR 01 - D
1/4" = 1'-0"
9
BR 02 - A
1/4" = 1'-0"
10
BR 02 - B
1/4" = 1'-0"
11
BR 03 - A
1/4" = 1'-0"
12
BR 03 - B
1/4" = 1'-0"
C
13
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
BR 03 - C
1/4" = 1'-0"
14
BR 03 - D
1/4" = 1'-0"
15
BR 04 - A
1/4" = 1'-0"
16
BR 04 - B
1/4" = 1'-0"
17
BR 04 - C
1/4" = 1'-0"
18
CLOSET 01 - A
1/4" = 1'-0"
19
CLOSET 01 - B
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
B
20
CLOSET 01 - C
1/4" = 1'-0"
21
CLOSET 02 - A
1/4" = 1'-0"
LEVEL 2
12'-0"
22
CLOSET 02 - B
1/4" = 1'-0"
LEVEL 2
12'-0"
23
CLOSET 02 - C
1/4" = 1'-0"
24
CLOSET 03 - A
1/4" = 1'-0"
25
CLOSET 03 - B
1/4" = 1'-0"
26
CLOSET 03 - C
1/4" = 1'-0"
27
CLOSET 03 - D
1/4" = 1'-0"
28
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
LEVEL 1
0'-0"
CLOSET 04 - A
1/4" = 1'-0"
LEVEL 2
12'-0"
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
LEVEL 1
0'-0"
29
CLOSET 04 - B
1/4" = 1'-0"
LEVEL 1
0'-0"
30
CLOSET 04 - C
1/4" = 1'-0"
Drawing Title:
LEVEL 1
0'-0"
31
INTERIOR
ELEVATIONS
CLOSET 04 - D
1/4" = 1'-0"
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A07
1
3
2
LEVEL 2
12'-0"
4
LEVEL 2
12'-0"
5
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
1
6
LIVING 01 - A
1/4" = 1'-0"
LIVING 02 - B
1/4" = 1'-0"
LEVEL 1
0'-0"
2
LIVING 01 - B
1/4" = 1'-0"
LEVEL 1
0'-0"
3
LIVING 01 - C
1/4" = 1'-0"
LEVEL 1
0'-0"
4
LIVING 01 - D
1/4" = 1'-0"
LEVEL 1
0'-0"
5
Revision:
Date:
LIVING 02 - A
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
7
LIVING 02 - C
1/4" = 1'-0"
8
LIVING 02 - D
1/4" = 1'-0"
9
LIVING 03 - A
1/4" = 1'-0"
C
10
LIVING 03 - B
1/4" = 1'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 2
12'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
LEVEL 1
0'-0"
11
LIVING 03 - C
1/4" = 1'-0"
12
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
LEVEL 1
0'-0"
LIVING 03 - D
1/4" = 1'-0"
B
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
INTERIOR
ELEVATIONS
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A08
1
3
2
4
5
Door Schedule
B
A
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
2'-6"
2'-6"
2'-6"
2'-6"
2'-6"
2'-6"
2'-6"
2'-6"
2'-6"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
2'-10"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
5'-8 1/8"
5'-8 1/8"
6'-0"
6'-0"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-10"
7'-0"
7'-0"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
0'-1 1/2"
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
WOOD
HM
WOOD
WOOD
WOOD
WOOD
HM
WOOD
WOOD
WOOD
HM
WOOD
WOOD
HM
HM
GLASS
GLASS
Finish
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
STAINED
PAINTED
STAINED
STAINED
STAINED
STAINED
PAINTED
STAINED
STAINED
STAINED
PAINTED
STAINED
STAINED
PAINTED
PAINTED
Materi
Fire
al
Glazing Rating Hardware Type
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
HM
ALUM
ALUM
Finish
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
PAINTED
NOT FOR
CONSTRUCTION
Jamb Head Comments
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
2'-4"
2'-10"
3'-2"
3'-4"
4'-5 1/2"
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
02
26
02
02
02
02
02
02
02
03
03
03
03
03
03
03
03
03
03
03
04
04
04
05
04
04
04
04
05
04
04
04
05
04
04
06
07
08
08
Frame
6'-6"
7'-3"
D
102
103
106
107
109
110
114
115
118
119
120
121
128
129
130
131
134
135
137
138
139
141
142
143
171
174
175
176
180
183
185
186
201
202
203
205
206
208
209
210
104
105
124
147
148
212
213
291
292
117
122
123
127
132
136
140
172
181
199
207
101
108
111
112
116
133
144
173
179
182
204
211
214
296
297
125
145
305A
305B
Width
Door
Heigh Thicknes
t
s
Material
6'-10"
Door
Num Ty
ber pe
Scales:
1/2" = 1'-0"
FDWD1301
Jacobs Project No.:
DOOR LEGEND
1/2" = 1'-0"
Drawing Title:
SCHEDULES
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A09
A
West Wall
Ceiling
Ceiling Finish Height
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
R.O.
Type
Mark Width Height
Type
Glazing
Manuf
acturer Model Material Finish Head Jamb Sill Thickness Type
Head
Height Comments
NOT FOR
CONSTRUCTION
Comments
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
02
03
03
03
03
03
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
1'-4"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-10"
3'-10"
3'-10"
4'-0"
4'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
3'-8"
3'-8"
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Fixed with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
Double Hung with Trim
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
7'-2 1/4"
8'-4 3/4"
7'-2 1/4"
7'-1 3/4"
7'-2 1/4"
4'-2 1/2"
1'-6 1/2"
3'-2 1/2"
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
B
CARPET
TILE
CARPET
TILE
N/A
TILE
CARPET
CARPET
TILE
CARPET
CARPET
TILE
TILE
CARPET
TILE
CARPET
CARPET
TILE
CARPET
TILE
CARPET
CARPET
N/A
TILE
TILE
TILE
CARPET
CARPET
TILE
CARPET
TILE
CARPET
CARPET
TILE
CARPET
CARPET
CARPET
TILE
TILE
CARPET
CARPET
CARPET
TILE
CARPET
TILE
TILE
TILE
N/A
TILE
CARPET
CARPET
TILE
CARPET
CARPET
TILE
TILE
CARPET
CARPET
TILE
CARPET
CARPET
TILE
N/A
TILE
TILE
TILE
TILE
TILE
TILE
TILE
CARPET
CARPET
TILE
CARPET
CARPET
TILE
TILE
CARPET
CARPET
TILE
CARPET
CARPET
TILE
N/A
TILE
Window Schedule
4'-0 1/2"
5'-3 1/2"
C
BEDROOM
BATHROOM
CLOSET
LAUNDRY
MECH.
BATHROOM
CLOSET
BEDROOM
BATHROOM
CLOSET
BEDROOM
LIVING
KITCHEN
CLOSET
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
BATHROOM
CLOSET
BEDROOM
MECH.
LAUNDRY
LIVING
KITCHEN
BEDROOM
CLOSET
BATHROOM
CLOSET
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
BEDROOM
CLOSET
BATHROOM
BATHROOM
BEDROOM
CLOSET
CLOSET
BATHROOM
BEDROOM
LIVING
KITCHEN
LAUNDRY
MECH.
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
CLOSET
LIVING
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
CLOSET
LAUNDRY
MECH.
KITCHEN
SUPPLY STORAGE ROOM
PUBLIC TOILET
BULK STORAGE
MULTI-PURPOSE AREA
VENDING
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
CLOSET
LIVING
BATHROOM
BEDROOM
BEDROOM
BATHROOM
CLOSET
CLOSET
LAUNDRY
MECH.
KITCHEN
Base
Finish
5
Scales:
1/2" = 1'-0"
FDWD1301
Jacobs Project No.:
Drawing Title:
1'-11 1/2"
D
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
171
172
173
174
175
178
179
180
181
182
183
185
186
291
292
293
295
296
297
305
307
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
Room Name
Floor
Finish
Room Schedule
FINISHES
WALLS
North Wall
East Wall
South Wall
4
3'-11 1/2"
Room
Numb
er
3
2
3'-3 1/2"
1
SCHEDULES
WINDOW LEGEND
1/2" = 1'-0"
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
A13
2
4
LIGHTING FIXTURES
SWITCHES AND CONTROLS
DISTRIBUTION EQUIPMENT (EQUIPMENT PREFIX)
SUBSCRIPTS: A1b = TYPE A, CIRCUIT 1, CONTROL ZONE b
SUBSCRIPTS: 3b = TYPE 3, CONTROL ZONE b
LIGHTING OR RECEPTACLE PANELBOARD
TOGGLE SWITCH: 3 = 3-WAY, 2 = DOUBLE POLE, 4 = 4 WAY, DM =
DIMMER, K = KEY OPERATED, EX = EXPLOSION
PROOF, T = TIMER OPERATED, LM = LOW
VOLTAGE MASTER, OC = OCCUPANCY SENSOR
SWITCH, F = FUSED, M = MANUAL MOTOR
STARTER, CB = CIRCUIT BREAKER
RELAY CABINET
3
CEILING OR PENDANT INCANDESCENT, HID OR COMPACT FLUORESCENT
CEILING OR PENDANT INCANDESCENT, HID OR COMPACT
FLUORESCENT EMERGENCY LIGHT
CEILING OR PENDANT HID WITH QUARTZ RESTRIKE
10
FLUORESCENT STRIP LIGHT
DISTRIBUTION OR POWER PANELBOARD
MOTOR CONTROL CENTER
SWITCHBOARD
DIMMER, 6 = 600W, 10 = 1000W
WALL MOUNTED INCANDESCENT, HID OR COMPACT FLUORESCENT
D
3
M
OCCUPANCY SENSOR, WALL MOUNTED OR CEILING MOUNTED,
DIRECTIONAL
M
OCCUPANCY SENSOR, CEILING MOUNTED, MULTI DIRECTIONAL
TIME CLOCK
PUSHBUTTON OR CONTROL STATION
CONTACTOR
RACEWAYS AND WIRES
4. FOR EXACT LOCATIONS OF RECESSED LIGHTING FIXTURES, REFERENCE
ARCHITECTURAL REFLECTED CEILING PLANS. COORDINATE
INSTALLATION OF LIGHTING FIXTURES WITH LOCATION OF EQUIPMENT,
PIPING AND DUCTWORK.
CONDUIT OR CABLE BELOW SLAB, IN SLAB OR UNDERGROUND
CONDUIT OR CABLE TURNING UP
0
MOTOR STARTER, 0 = STARTER SIZE
FLOODLIGHT
30
(12)
0
COMBINATION MOTOR STARTER AND DISCONNECT SWITCH
30 = SWITCH AMPERE RATING
(12) = FUSE AMPERE RATING
0 = STARTER SIZE
100
(70)
1
COMBINATION MOTOR STARTER AND CIRCUIT PROTECTOR
100 = FRAME SIZE
(70) = TRIP RATING
1 = STARTER SIZE
30
(15)
FUSED DISCONNECT SWITCH
30 = SWITCH AMPERE RATING
(15) = FUSE AMPERE RATING
OUTLET BOX WITH BLANK COVER
NON-FUSED DISCONNECT SWITCH
30 = SWITCH AMPERE RATING
JUNCTION BOX, FLOOR DUCT SYSTEM
ROADWAY OR PARKING LOT STANDARD
POST TOP WALKWAY OR PARKING LOT STANDARD
BUILDING MOUNTED WALLPACK
IN POOL WET NICHE LIGHT
LIGHTING TRACK WITH FIXTURES
30
DOCK LIGHT
CONDUIT CAPPED
WALL MOUNTED EXIT SIGN
TELEPHONE TERMINAL BOARD (TB)
SHADING INDICATES ILLUMINATED FACE OF EXIT SIGN
TELEPHONE TERMINAL CABINET (TC)
ARROW INDICATES EXIT SIGN DIRECTIONAL ARROW
TELEPHONE WALL OUTLET, W = WALL, P = PUBLIC,
F = FIRE FIGHTER, WP = WEATHERPROOF
#10,3/4"
JUNCTION BOX
PULL BOX
FCP
FIRE ALARM CONTROL PANEL
LOC
LOCAL OPERATING CONSOLE
FSA
FIRE ALARM SYSTEM ANNUNCIATOR
NAC
NAC EXTENDER PANEL (REMOTE POWER SUPPLY)
FTP
FIRE ALARM TRANSPONDER PANEL
TELEPHONE FLOOR OUTLET OR SERVICE FITTING
SPECIAL RECEPTACLE, X = NEMA DESIGNATION
B
PUBLIC ADDRESS PUSHBUTTON
DUPLEX FLOOR RECEPTACLE
VOLUME CONTROL AND CHANNEL SELECTOR
SINGLE FLOOR RECEPTACLE
CEILING MOUNTED SPEAKER, S=SOUND MASKING
DUPLEX RECEPTACLE AND DATA OUTLET IN
FLOOR BOX OR SERVICE FITTING
I
E
U
SPECIAL FLOOR RECEPTACLE
DUPLEX RECEPTACLE AND TELEPHONE OUTLET IN
FLOOR BOX OR SERVICE FITTING
P
WALL MOUNTED SPEAKER
S
MASTER CLOCK (CM)
C
C C
P
C
EOL
75
DOUBLE FACE CLOCK, A = ANALOG, D = DIGITAL
F
75
PROGRAM BELL
M
75
PROGRAM BUZZER
POKE-THROUGH WITH DUPLEX RECEPTACLE AND
FOUR CATEGORY 5 COMMUNICATION JACKS
BUZZER SWITCH
OFF AIR ANTENNA
TV
75
M
PARTITION SENSOR, 10= 1000, 6=600
75
F
A
LEGEND ABBREVIATIONS
FA
FLOUR
FIRE ALARM
FLOURESCENT
G
GFCI
GROUND
GROUND FAULT CIRCUIT INTERUPTER
INCND
INCANDESCENT
ELEVATOR RECALL PHOTOELECTRIC SMOKE DETECTOR
LTG
LIGHTING
DUCT SMOKE DETECTOR
MECH
MIN
MTD
MECHANICAL
MINIMUM
MOUNTED
N
NIC
NP
NEUTRAL
NIT IN CONTRACT
NOT PERMITTED
WALL-MOUNTED MASS NOTIFICATION STROBE (AMBER)
(NUMBER INDICATES CANDELA RATING)
EXP = EXPLOSION PROOF
PC
PWR
PERSONAL COMPUTER
POWER
WALL-MOUNTED SPEAKER/STROBE (CLEAR)
(NUMBER INDICATES CANDELA RATING)
EXP = EXPLOSION PROOF
QTY
QUANTITY
RECP
REQD
RM
RECEPTACLE
REQUIRED
ROOM
SC
SS
SW
SPLIT CIRCUIT
SINGLE STATION SMOKE ALARM
SWITCH
TEL
TELCOM
TYP
TELEPHONE
TELECOMMUNICATIONS
TYPICAL
UPS
UNINTERUPTABLE POWER SUPPLY
WP
WEATHER PROOF
XFRMR
TRANSFORMER
PHOTOELECTRIC SMOKE DETECTOR
IONIZATION SMOKE DETECTOR
SUB FLOOR SMOKE DETECTOR
END OF LINE DEVICE
WALL-MOUNTED FIRE ALARMSTROBE (CLEAR)
(NUMBER INDICATES CANDELA RATING)
EXP = EXPLOSION PROOF
WALL-MOUNTED FIRE ALARM SPEAKER
F
TELEVISION OUTLET
10
11. ALL EMERGENCY LIGHT FIXTURES SHALL BE UNSWITCHED SO AS
TO BE UTILIZED AS NIGHT LIGHTS.
ELECTRICAL
ELEVATION
EMERGENCY
SINGLE FACE CLOCK, A = ANALOG, D = DIGITAL
PROGRAM CLOCK WITH INTERCOM
DUPLEX RECEPTACLE, TELEPHONE AND DATA
OUTLET IN FLOOR BOX OR SERVICE FITTING
10. SIZE OUTLET AND JUNCTION BOXES PER 2005 NEC ARTICLE 314,
UNLESS OTHERWISE NOTED.
ELEC
ELEV
EMER
MANUAL PULL STATION
MICROPHONE OUTLET
DUPLEX CEILING RECEPTACLE
DOUBLE DUPLEX FLOOR RECEPTACLE
F
EQUIPMENT RACK
M
9. CONDUITS ARE 3/4", UNLESS OTHERWISE NOTED.
DIGITAL ALARM COMMUNICATOR TRANSMITTER
195 RATE OF RISE HEAT DETECTOR
R
195
FIXED TEMPERATURE HEAT DETECTOR
F
MISCELLANEOUS SYSTEMS
CLOCK RECEPTACLE WITH HANGER
8. WIRES ARE #12, UNLESS OTHERWISE NOTED.
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ARCHITECTURAL
AVERAGE
LCD ANNUNCIATOR
LCD
COMBINATION TELEPHONE IN COMMON FLOOR BOX WITH
ELECTRICAL OUTLET
DATA CEILING OUTLET
DOUBLE DUPLEX RECEPTACLE
DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT
DACT
COMBINATION TELEPHONE AND DATA WALL OUTLET, 2 = 2-PORT,
4 = 4-PORT, EXP = EXPLOSION PROOF, M = MODULAR
SINGLE RECEPTACLE
X
DATA OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL
OUTLET
4'-0"
LIGHTING SWITCHES
1'-6"
GENERAL PURPOSE RECEPTACLES
COUNTER TOP RECEPTACLES
8 INCHES ABOVE COUNTER
1'-6"
TELEPHONE OUTLETS
1'-6"
DATA OUTLETS
1'-6"
TELEVISION OUTLET (COAX)
AFF
AFG
ARCH
AVG
DATA WALL OUTLET, D = DATA, F = FAX, S=SIPRNET
4
By: Description:
7. MOUNTING HEIGHTS ABOVE FINISHED FLOOR ARE AS FOLLOWS, UNLESS
OTHERWISE NOTED:
FIRE ALARM & MASS NOTIFICATION SYSTEM LEGEND
RECEPTACLES
SUBSCRIPTS: 1b = CIRCUIT 1, CONTROL ZONE b
GFCI = GROUND FAULT CIRCUIT INTERRUPTER
WP = WEATHERPROOF WHILE IN USE COVER
S = SWITCHED, F = FLUSH FLOOR,
SM = SURFACE MOUNT FLOOR
DUPLEX RECEPTACLE
Revision:
Date:
6. MOUNTING HEIGHTS FOR WALL MOUNTED FIXTURES OR DEVICES ARE TO
CENTER LINE OF OUTLET BOXES, UNLESS OTHERWISE NOTED.
WIRING: LONG SLASH = NEUTRAL (N)
SHORT SLASH = HOT
SHORT SLASH WITH HOOK = SWITCHED
LONG SLASH WITH DOT = GROUND (G)
#10 = WIRE SIZE
3/4" = CONDUIT SIZE
C
TELEPHONE AND DATA COMMUNICATIONS
501 North Broadway, St. Louis, Missouri 63102-2121
5. MOUNTING HEIGHTS FOR CEILING MOUNTED FIXTURES OR DEVICES ARE
TO BOTTOM OF FIXTURES OR DEVICES, UNLESS OTHERWISE NOTED.
LP1-2,4,6 HOMERUN, LP1 = PANEL DESTINATION, 2,4,6 = CIRCUITS
STEP OR AISLE LIGHT
CEILING OR PENDANT MOUNTED EXIT SIGN
NOT FOR
CONSTRUCTION
CONDUIT OR CABLE TURNING DOWN
REMOTE EMERGENCY HEAD
SPOTLIGHT, ARROW INDICATES DIRECTION OF AIM
2. LIGHTING CONTROL ZONE DESIGNATIONS INDICATE WHICH DEVICES
CONTROL WHICH GROUPS OF FIXTURES. WHERE LOCAL SWITCHES AND
DIMMERS ARE SHOWN, OR WHERE NO CONTROL ZONE DESIGNATION IS
INDICATED, LOCAL CONTROL DEVICES SHALL ONLY CONTROL FIXTURES IN
THEIR RESPECTIVE ROOMS.
3. SIZE OUTLET AND JUNCTION BOXES PER 2005 NEC ARTICLE 314,
UNLESS OTHERWISE NOTED.
CONDUIT OR CABLE BELOW RAISED FLOOR
FLUORESCENT EMERGENCY LIGHT
BATTERY PACK WITH HEADS
1. ALL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES SHOWN ARE NOT
NECESSARILY USED ON THIS PROJECT.
TRANSFORMER
CONDUIT OR CABLE (RUN AS INDICATED)
FLUORESCENT
PHOTOCELL
ELECTRICAL GENERAL NOTES
911 Central Parkway N., Suite 425 San Antonio, TX 78323
FLUORESCENT STRIP EMERGENCY LIGHT
FLUORESCENT WITH ASYMMETRICAL DISTRIBUTION
LINE REPRESENTS LAMP AXIS
5
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
1
CEILING-MOUNTED MASS NOTIFICATION STROBE (AMBER)
(NUMBER INDICATES CANDELA RATING)
CEILING-MOUNTED SPEAKER/STROBE (CLEAR)
(NUMBER INDICATES CANDELA RATING)
M
MINI-SPEAKER
FS
SPRINKLER FLOW SWITCH
TS
SPRINKLER TAMPER SWITCH
AIM
ADDRESSABLE INTERFACE MODULE
ACM
ADDRESSABLE CONTROL MODULE
DOOR HOLD AND RELEASE DEVICE
Scales:
NOT TO SCALE
Jacobs Project No.:
FDWD1301
Drawing Title:
NOTES AND
SYMBOLS
N
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
E-001
1
3
2
4
5
42 W
25 W
18 W
18 W
18 W
25 W
42TRT
T8
18DTT
18DTT
-T8
120 V
120 V
120 V
120 V
120 V
120 V
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
MANUFACTURER
LITHONIA
LITHONIA
LITHONIA
LITHONIA
-LITHONIA
FIXTURE CATALOG NUMBER
WST 42TRT MDU 120 ELDWC PE LPI
WP 2 25 MVOLT S2 BF GEB10PS 2/1
LF6 2/18DTT F602A 120 GEB10
LF6 2/18DTT F602A 120 GEB10 EL
-SM 1 25 MVOLT ES GEB10RS
REMARKS
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
1
2
2
2
3
1
LAMP TYPE
FIXTURE
VA
40 VA
40 VA
30 VA
30 VA
50 VA
20 VA
FIXTURE INPUT VOLTAGE
LAMP WATTAGE
FIXTURE DESCRIPTION
Exterior Wall
OUTDOOR WALL LIGHT WITH EMERGENCY BALLAST SURFACE
Bathroom Wall
WALL LIGHT
SURFACE
Ceiling
CAN LIGHT
RECESSED
Emergency Ceiling CAN LIGHT WITH EMERGENCY BALLAST
RECESSED
Ceiling Fan
CEILING FAN
SURFACE
Mech/Laundry Wall WALL LIGHT
SURFACE
LAMP QUANTITY
MOUNTING
D
Type
Mark
A
C
D
D
F
G
TYPE
LIGHTING FIXTURE SCHEDULE
C
B
Scales:
Jacobs Project No.:
A
FDWD1301
Drawing Title:
LIGHTING
SCHEDULE
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
E-501
1
3
2
4
5
KEYED NOTES
Panel
PP-A
Voltage
120 V / 208 V
Phase
Three Phase
Mount
TBD
D
2
C
2
LIGHTING - WEST
LIGHTING - EAST
SPARE
SPARE
KITCHEN 113 REFRIGERATOR
KITCHEN 113 COUNTER TOP REC
KITCHEN 113 - 1/2HP
DISPOSER
KITCHEN 113 DISHWASHER
KITCHEN 113 MICROWAVE
KITCHEN 113 COUNTER TOP REC
Trip
15 A
Enclosure
Type 1
Poles
1
Ckt. No.
1
1
1
3
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
15 A
15 A
15 A
15 A
1
1
1
1
1
15 A
1
33
20 A
1
35
15 A
1
37
20 A
1
39
15 A
1
41
1
B
C
Ckt. No.
2
Poles
2
2
Trip
60 A
THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A
COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER.
LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO
1500VA PER NEC 220.52.
NOT FOR
CONSTRUCTION
Load Name
KITCHEN 113 - RANGE
7
1
720 VA / 2880 VA
9
1
540 VA / 2880 VA
11
1
13
1
540 VA / 960 VA
19
1
540 VA / 696 VA
1
23
25
27
29
31
20 A
8
2
30 A
12
LAUNDRY 104 WASHER
LAUNDRY 104 - DRYER
2
20 A
HVAC CENTRAL (1HP)
1
15 A
1
15 A
1
15 A
1
15 A
24
26
28
30
32
1
1
1
1
1
15 A
15 A
15 A
15 A
15 A
HVAC - BEDROOM 101
(1/4HP)
HVAC - BEDROOM 108
(1/4HP)
HVAC - BEDROOM 111
(1/4HP)
HVAC - BEDROOM 116
(1/4HP)
SPARE
SPARE
SPARE
SPARE
SPARE
34
1
15 A
SPARE
36
1
15 A
SPARE
38
1
15 A
SPARE
40
1
15 A
SPARE
42
1
15 A
SPARE
16
360 VA / 696 VA
360 VA / 696 VA
21
1
1
2
Revision:
Date:
By: Description:
14
17
1
6
10
540 VA / 960 VA
15
1
501 North Broadway, St. Louis, Missouri 63102-2121
4
720 VA / 1500 VA
18
20
1260 VA / 696 VA
22
450 VA / 0 VA
460 VA / 0 VA
1500 VA / 0 VA
180 VA / 0 VA
1176 VA / 0 VA
744 VA / 0 VA
1500 VA / 0 VA
180 VA / 0 VA
Phase B
14772 VA
Mfg. / Type
--
Location
TBD
720 VA / 5760 VA
5
1
1
A
720 VA / 5760 VA
1
MCB
911 Central Parkway N., Suite 425 San Antonio, TX 78323
15 A
Phase A
15340 VA
Mains
200 A
Phase C
6582 VA
Modifications
--
1
1
1
1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
Load Name
BEDROOM 101 - DESK
AND CONV REC
BEDROOM 101 - CONV
REC
BEDROOM 108 - DESK
AND CONV REC
BEDROOM 108 - CONV
REC
BEDROOM 111 - DESK
AND CONV REC
BEDROOM 111 - CONV
REC
BEDROOM 116 - DESK
AND CONV REC
BEDROOM 116 - CONV
REC
BATHROOMS 102, 109 CONV REC
BATHROOMS 106, 115 CONV REC
LIVING 112 - REC
Wires
4 Wires
Total VA
36694 VA
Amps RMS. Sym.
--
B
Scales:
Jacobs Project No.:
A
FDWD1301
Drawing Title:
PANEL SCHEDULE A
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
E-502
1
3
2
4
5
KEYED NOTES
Panel
PP-B
Voltage
120 V / 208 V
Phase
Three Phase
Mount
TBD
D
2
C
2
LIGHTING - NORTH
LIGHTING - SOUTH
SPARE
SPARE
KITCHEN 126 REFRIGERATOR
KITCHEN 126 COUNTER TOP REC
KITCHEN 126 DISHWASHER
KITCHEN 126 DISPOSAL (1/2HP)
KITCHEN 126 MICROWAVE
KITCHEN 126 COUNTER TOP REC
Trip
15 A
Enclosure
Type 1
Poles
1
Ckt. No.
1
1
1
3
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
15 A
15 A
15 A
15 A
1
1
1
1
1
15 A
1
33
15 A
1
35
20 A
1
37
20 A
1
39
15 A
1
41
1
B
C
Ckt. No.
2
Poles
2
2
Trip
60 A
THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A
COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER.
LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO
1500VA PER NEC 220.52.
NOT FOR
CONSTRUCTION
Load Name
KITCHEN 126 - RANGE
7
1
720 VA / 2880 VA
9
1
540 VA / 2880 VA
11
1
13
1
540 VA / 960 VA
19
1
720 VA / 696 VA
1
23
25
27
29
31
1
20 A
8
2
30 A
12
LAUNDRY 124 WASHER
LAUNDRY 124 - DRYER
2
20 A
HVAC - CENTRAL (1HP)
1
15 A
1
15 A
1
15 A
1
15 A
24
26
28
30
32
1
1
1
1
1
15 A
15 A
15 A
15 A
15 A
HVAC - BEDROOM 117
(1/4HP)
HVAC - BEDROOM 127
(1/4HP)
HVAC - BEDROOM 122
(1/4HP)
HVAC - BEDROOM 132
(1/4HP)
SPARE
SPARE
SPARE
SPARE
SPARE
34
1
15 A
SPARE
36
1
15 A
SPARE
38
1
15 A
SPARE
40
1
15 A
SPARE
42
1
15 A
SPARE
16
360 VA / 696 VA
360 VA / 696 VA
21
1
6
2
Revision:
Date:
By: Description:
14
17
1
501 North Broadway, St. Louis, Missouri 63102-2121
10
720 VA / 960 VA
15
1
4
540 VA / 1500 VA
18
20
1440 VA / 696 VA
22
410 VA / 0 VA
440 VA / 0 VA
1500 VA / 0 VA
180 VA / 0 VA
744 VA / 0 VA
1176 VA / 0 VA
1500 VA / 0 VA
180 VA / 0 VA
Phase B
15132 VA
Mfg. / Type
--
1
Location
TBD
720 VA / 5760 VA
5
1
1
A
540 VA / 5760 VA
MCB
911 Central Parkway N., Suite 425 San Antonio, TX 78323
15 A
Phase A
15572 VA
Mains
200 A
Phase C
6110 VA
Modifications
--
1
1
1
1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
Load Name
BEDROOM 117 - DESK
AND CONV REC
BEDROOM 117 - CONV
REC
BEDROOM 127 - DESK
AND CONV REC
BEDROOM 127 - CONV
REC
BEDROOM 122 - DESK
AND CONV REC
BEDROOM 122 - CONV
REC
BEDROOM 132 - DESK
AND CONV REC
BEDROOM 132 - CONV
REC
BATHROOMS 118, 120 CONV REC
BATHROOMS 129, 131 CONV REC
LIVING 125 - REC
Wires
4 Wires
Total VA
36814 VA
Amps RMS. Sym.
--
B
Scales:
Jacobs Project No.:
A
FDWD1301
Drawing Title:
PANEL SCHEDULE B
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
E-503
1
3
2
4
5
KEYED NOTES
Voltage
120 V / 208 V
Phase
Three Phase
Mount
TBD
Load Name
BEDROOM 133 - DESK
AND CONV REC
BEDROOM 133 - CONV
REC
BEDROOM 144 - DESK
AND CONV REC
BEDROOM 144 - CONV
REC
BEDROOM 136 - DESK
AND CONV REC
BEDROOM 136 - CONV
REC
BEDROOM 140 - DESK
AND CONV REC
BEDROOM 140 - CONV
REC
BATHROOMS 134, 138 CONV REC
BATHROOMS 143, 139 CONV REC
LIVING 145 - REC
D
2
C
2
LIVING 145 - REC
LIGHTING - EAST
LIGHTING - WEST
SPARE
KITCHEN 146 REFRIGERATOR
KITCHEN 146 COUNTER TOP REC
KITCHEN 146 DISPOSAL (1/2HP)
KITCHEN 146 DISHWASHER
KITCHEN 146 COUNTER TOP REC
KITCHEN 146 MICROWAVE
Trip
15 A
Wires
4 Wires
Mains
200 A MCB
Enclosure
Type 1
Poles
1
Ckt. No.
1
A
540 VA / 5760 VA
B
1
Location
2
TBD
C
Ckt. No.
2
Poles
2
Trip
60 A
Load Name
KITCHEN 146 - RANGE
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
1
15 A
15 A
15 A
15 A
15 A
1
1
1
1
1
15 A
1
33
20 A
1
35
15 A
1
37
15 A
1
39
20 A
1
41
Phase A
15350 VA
3
1
720 VA / 5760 VA
5
1
7
1
720 VA / 2880 VA
9
1
720 VA / 2880 VA
11
1
13
1
19
1
1
1
1
23
25
27
29
31
8
2
30 A
LAUNDRY 147 WASHER
LAUNDRY 147 - DRYER
2
Revision:
Date:
HVAC - CENTRAL (1HP)
12
1
15 A
1
15 A
1
15 A
1
15 A
440 VA / 0 VA
24
26
28
30
32
1
1
1
1
1
15 A
15 A
15 A
15 A
15 A
HVAC - BEDROOM 133
(1/4HP)
HVAC - BEDROOM 144
(1/4HP)
HVAC - BEDROOM 136
(1/4HP)
HVAC - BEDROOM 140
(1/4HP)
SPARE
SPARE
SPARE
SPARE
SPARE
180 VA / 0 VA
34
1
15 A
SPARE
36
1
15 A
SPARE
38
1
15 A
SPARE
40
1
15 A
SPARE
42
1
15 A
SPARE
By: Description:
14
720 VA / 696 VA
16
360 VA / 696 VA
360 VA / 696 VA
18
20
900 VA / 696 VA
22
1080 VA / 0 VA
470 VA / 0 VA
1500 VA / 0 VA
1176 VA / 0 VA
744 VA / 0 VA
180 VA / 0 VA
1500 VA / 0 VA
Phase B
13892 VA
Mfg. / Type
--
20 A
20 A
720 VA / 960 VA
21
1
1
2
17
1
6
10
720 VA / 960 VA
15
1
501 North Broadway, St. Louis, Missouri 63102-2121
4
540 VA / 1500 VA
LOAD FOR THIS SMALL-APPLIANCE OR LAUNDRY CIRCUIT IS SET TO
1500VA PER NEC 220.52.
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
1
15 A
THE NOTATION "(AFCI)" INDICATES THAT THIS CIRCUIT BREAKER IS A
COMBINATION-TYPE ACR-FAULT CIRCUIT INTERUPTER.
Phase C
8532 VA
Modifications
--
1
1
1
1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
Panel
PP-C
Total VA
37774 VA
Amps RMS. Sym.
--
B
Scales:
Jacobs Project No.:
A
FDWD1301
Drawing Title:
PANEL SCHEDULE C
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
E-504
1
3
2
4
5
GENERAL NOTES
1. CEILING MOUNTED LIGHT FIXTURES ARE MOUNTED AT 102" AFF.
2. WALL MOUNTED LIGHT FIXTURES IN BATHROOMS ARE COORDINATED
TO BE MOUNTED ABOVE THE WALL MIRROR.
NOT FOR
CONSTRUCTION
A
BEDROOM
BEDROOM
MECH.
117
127
123
G
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
LAUNDRY
F
F
124
G
CLOSET
CLOSET
119
128
Revision:
Date:
D
BATHROOM
By: Description:
BATHROOM
KITCHEN
118
126
D
D
129
D
D
C
C
23
D
F
25
C
BATHROOM
C
120
D
D
131
CLOSET
CLOSET
121
130
C
BATHROOM
D
D
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
D
D
F
F
LIVING
125
BEDROOM
BEDROOM
122
C1
132
PLAN B LIGHTING PLAN
1/4" = 1'-0"
C3
BATHROOM
102
BATHROOM
A
106
C
BEDROOM
C
G
MECH.
101
CLOSET
B
PLAN B LIGHTING AXON
D
105
103
BEDROOM
108
CLOSET
D
107
LAUNDRY
D
104
F
F
G
D
D
CLOSET
CLOSET
D
110
D
114
F
BATHROOM
BATHROOM
LIVING
109
112
D
D
115
D
D
C
C
D
KITCHEN
113
D
Scales:
D
1/4" = 1'-0"
Jacobs Project No.:
A
F
Drawing Title:
F
BEDROOM
BEDROOM
111
116
LIGHTING
PLANS/AXON
N
23
PLAN A LIGHTING PLAN
A1
1/4" = 1'-0"
FDWD1301
25
A3
PLAN A LIGHTING AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
EL101
1
3
2
4
5
GENERAL NOTES
1. CEILING MOUNTED LIGHT FIXTURES ARE MOUNTED AT 102" AFF.
2. WALL MOUNTED LIGHT FIXTURES IN BATHROOMS ARE COORDINATED
TO BE MOUNTED ABOVE THE WALL MIRROR.
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
LAUNDRY
147
KITCHEN
G
146
MECH.
G
148
A
D
BEDROOM
LIVING
BEDROOM
133
145
144
B
F
F
F
BATHROOM
BATHROOM
134
143
D
C
CLOSET
CLOSET
137
141
D
CLOSET
D
D
135
D
D
CLOSET
C
142
D
D
D
C
Scales:
C
F
Jacobs Project No.:
BEDROOM
136
D
BATHROOM
138
140
D
27
25
FDWD1301
Drawing Title:
LIGHTING
PLANS/AXON
BATHROOM
139
N
PLAN C LIGHTING PLAN
A1
1/4" = 1'-0"
1/4" = 1'-0"
F
BEDROOM
A
By: Description:
A3
PLAN C LIGHTING AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
EL102
1
3
2
4
5
GENERAL NOTES
1. RECEPTACLES ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
GFCI RECEPTACLES ARE MOUNTED AT 48" AFF UNLESS OTHERWISE
NOTED.
MECH.
123
2. ALL RECEPTACLES SHALL BE ARC-FAULT CIRCUIT INTERUPTER TYPE
EXCEPT WHEN LOCATED IN KITCHENS, BATHROOMS, AND OUTDOORS.
6
NOT FOR
CONSTRUCTION
8,10
D
911 Central Parkway N., Suite 425 San Antonio, TX 78323
7
3
BEDROOM
BEDROOM
117
127
501 North Broadway, St. Louis, Missouri 63102-2121
21
5
1
LAUNDRY
124
31
17 (SC) BATHROOM
118
CLOSET
33
121
9
By: Description:
19 (SC)
129
35
39
MICROWAVE
2,4
84" AFF
CLOSET
BATHROOM
128
37
DISPOSER
DISHWASHER
120
41
CLOSET
REFRIGERATOR
119
BATHROOM
Revision:
Date:
CLOSET
BATHROOM
130
131
RANGE
13
11
15
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
LIVING
125
C
C1
BEDROOM
BEDROOM
122
132
PLAN B POWER PLAN
1/4" = 1'-0"
C3
17 (SC)
MECH.
8,10
6
PLAN B POWER AXON
19 (SC)
105
21
BATHROOM
BATHROOM
102
106
B
BEDROOM
BEDROOM
CLOSET
101
LAUNDRY
103
3
17 (SC)
109
108
107
104
1
BATHROOM
CLOSET
5
7
CLOSET
CLOSET
110
114
BATHROOM
115
LIVING
19 (SC)
112
11
DISHWASHER
KITCHEN
33
2,4
15
41
113
Scales:
39
BEDROOM
111
BEDROOM
9
DISPOSER
35
31 RANGE
MICROWAVE
84" AFF
REFRIGERATOR
Jacobs Project No.:
116
37
A
FDWD1301
Drawing Title:
13
POWER
PLANS/AXON
N
PLAN A POWER PLAN
A1
1/4" = 1'-0"
1/4" = 1'-0"
A3
PLAN A POWER AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
EP101
1
3
2
4
5
GENERAL NOTES
1. RECEPTACLES ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
GFCI RECEPTACLES ARE MOUNTED AT 48" AFF UNLESS OTHERWISE
NOTED.
2. ALL RECEPTACLES SHALL BE ARC-FAULT CIRCUIT INTERUPTER TYPE
EXCEPT WHEN LOCATED IN KITCHENS, BATHROOMS, AND OUTDOORS.
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
41 2,4
RANGE
MICROWAVE
84" AFF
35
31
6
8,10
MECH.
KITCHEN LAUNDRY
147
146
DISPOSER
148
REFRIGERATOR
39
DISHWASHER
1
23
5
37
33
LIVING
145
B
BEDROOM
133
7
3
By: Description:
BEDROOM
144
21
BATHROOM
134
17(SC) CLOSET
CLOSET
CLOSET
137
141
CLOSET
135
19(SC)
BATHROOM
143
142
15
11
Scales:
9
BEDROOM
136
13
17 (SC)
19 (SC)
1/4" = 1'-0"
BEDROOM
140
Jacobs Project No.:
A
FDWD1301
Drawing Title:
BATHROOM
BATHROOM
138
139
POWER
PLANS/AXON
N
A1
PLAN C POWER PLAN
1/4" = 1'-0"
1
PLAN C POWER AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
EP102
1
3
2
4
5
GENERAL NOTES
1. ALL SINGLE STATION SMOKE ALARMS WITHIN EACH DWELLING UNIT MUST
BE INTERCONNECTED TO SOUND AT ONCE.
NOT FOR
CONSTRUCTION
2. WALL MOUNTED FIRE ALARM SPEAKERS ARE MOUNTED AT 78" AFF.
MECH.
123
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
BEDROOM
LAUNDRY
BEDROOM
117
124
127
Revision:
Date:
119
118
CLOSET
BATHROOM
128
129
126
BATHROOM
CLOSET
CLOSET
BATHROOM
120
121
130
131
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
BATHROOM
KITCHEN
CLOSET
LIVING
C
125
BEDROOM
BEDROOM
122
C1
132
PLAN B FIRE ALARM PLAN
1/4" = 1'-0"
C3
BATHROOM
MECH.
BATHROOM
102
105
106
B
PLAN B FIRE ALARM AXON
LIVING
BEDROOM
CLOSET
101
112
LAUNDRY
CLOSET
104
107
103
BEDROOM
108
LIVING
BATHROOM
CLOSET
109
112
110
CLOSET
114
By: Description:
BATHROOM
115
KITCHEN
Scales:
113
BEDROOM
BEDROOM
111
116
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
FIRE ALARM
PLANS/AXON
N
A1
PLAN A FIRE ALARM PLAN
1/4" = 1'-0"
A3
PLAN A FIRE ALARM AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
FA101
1
3
2
4
5
GENERAL NOTES
1. ALL SINGLE STATION SMOKE ALARMS WITHIN EACH DWELLING UNIT MUST
BE INTERCONNECTED TO SOUND AT ONCE.
NOT FOR
CONSTRUCTION
2. WALL MOUNTED FIRE ALARM SPEAKERS ARE MOUNTED AT 78" AFF.
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
KITCHEN
146
LAUNDRY
MECH.
147
148
B
LIVING
BEDROOM
BEDROOM
145
133
144
BATHROOM
CLOSET
CLOSET
CLOSET
CLOSET
BATHROOM
134
135
137
141
142
143
By: Description:
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
BEDROOM
BEDROOM
136
140
BATHROOM
BATHROOM
138
139
Drawing Title:
FIRE ALARM
PLANS/AXON
N
PLAN C FIRE ALARM PLAN
A1
1/4" = 1'-0"
FDWD1301
1
PLAN C FIRE ALARM AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
FA102
1
3
2
4
5
GENERAL NOTES
1. DATA OUTLETS ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
NOT FOR
CONSTRUCTION
MECH.
123
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
BEDROOM
LAUNDRY
BEDROOM
117
124
127
Revision:
Date:
KITCHEN
CLOSET
BATHROOM
126
119
118
CLOSET
BATHROOM
128
129
BATHROOM
CLOSET
CLOSET
BATHROOM
120
121
130
131
By: Description:
LIVING
C
C1
BEDROOM
BEDROOM
122
132
PLAN B TELECOM PLAN
1/4" = 1'-0"
C3
B
BATHROOM
MECH.
BATHROOM
102
105
106
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
125
PLAN B TELECOM AXON
LIVING
BEDROOM
CLOSET
101
112
LAUNDRY
104
103
BATHROOM
BEDROOM
CLOSET
CLOSET
CLOSET
110
114
109
108
107
BATHROOM
115
LIVING
112
Scales:
BEDROOM
BEDROOM
111
116
A
1/4" = 1'-0"
Jacobs Project No.:
FDWD1301
Drawing Title:
TELECOM
PLANS/AXON
N
A1
PLAN A TELECOM PLAN
1/4" = 1'-0"
A3
PLAN A TELECOM AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
T-101
1
3
2
4
5
GENERAL NOTES
1. DATA OUTLETS ARE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
KITCHEN
LAUNDRY
MECH.
147
148
146
B
LIVING
BEDROOM
BEDROOM
145
133
BATHROOM
144
CLOSET
CLOSET
137
141
By: Description:
BATHROOM
134
143
CLOSET
CLOSET
135
142
Scales:
BEDROOM
BEDROOM
136
140
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
BATHROOM
BATHROOM
138
139
TELECOM
PLANS/AXON
N
A1
PLAN C TELECOM PLAN
1/4" = 1'-0"
A3
PLAN C TELECOM AXON
Date:
May 11, 2009
Designed By: Designer
Drawn By: SBW
Checked By: Checker
Drawing No.:
T-102
GENERAL NOTES AND SYMBOLS
FIRE SPRINKLER SYMBOLS
3
2
4
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
PIPING SYMBOLS
FIRE SPRINKLER GENERAL NOTES
5
FIRE ALARM/MASS NOTIFICATION SYSTEM
GENERAL NOTES
COMBINATION WET PIPE FIRE SPRINKLER/STANDPIPE SYSTEM RISER
FVC
A.
FIRE VALVE CABINET WITH 2-1/2" HOSE VALVE
ELBOW UP
4" x 2 1/2" x 2 1/2" FIRE DEPARTMENT CONNECTION
ELBOW DOWN
INSPECTOR'S TEST CONNECTION/AUXILIARY DRAIN
OPEN
D
VALVE IN DROP
B.
REFER TO SPECIFICATIONS FOR MATERIALS AND QUALITY OF CONSTRUCTION.
TWO WAY BACKFLOW PREVENTER TEST HEADER
VALVE IN CENTER DROP
C.
WALL POST INDICATOR VALVE WITH TAMPER SWITCH
VALVE IN RISE
RESIDENTIAL CONCEALED SPRINKLER WITH WHITE COVER PLATE
DIRECTION OF FLOW
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR THE LOCATION
OF ALL CEILING-MOUNTED DEVICES. FIELD VERIFY AND COORDINATE THE
LOCATIONS OF ALL SYSTEM COMPONENTS INCLUDING PIPING, ALARMS,
DRAINS, TEST POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL,
MECHANICAL AND ELECTRICAL EQUIPMENT WITHIN THE BUILDING.
DIRECTION OF SLOPE DOWN
FIRE ALARM/MASS NOTIFICATION SYMBOLS
D.
CONCENTRIC REDUCER
FACP
ADDRESSABLE FIRE ALARM CONTROL PANEL
ECCENTRIC REDUCER
RPS
P
FIRE ALARM REMOTE POWER SUPPLY
TEE OUTLET UP
MANUAL PULL STATION
TEE OUTLET DOWN
PHOTOELECTRIC SMOKE DETECTOR
SS
MN
XX
XX
C
MN
XX
XX
XX
MN
XX
XX
ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR WITH SOUNDER BASEINTERCONNECTED IN MULTIPLE ROOM DWELLING UNITS
STRAINER WITH
BLOWDOWN VALVE
WALL MOUNTED COMBINATION MASS NOTIFICATION AND FIRE ALARM
STROBE. CONTAINS AMBER STROBE LENS FOR MASS NOTIFICATION AND
CLEAR STROBE LENS FOR FIRE ALARM SYSTEM, (NUMBER INDICATES
MINIMUM FIRE ALARM STROBE CANDELA, "MN" ABOVE NUMBER
INDICATES MINIMUM MASS NOTIFICATION CANDELA. NOTE: MASS
NOTIFICATION CANDELA RATING SHOWN IS DERATED FOR AMBER STROBE
LENS).
CEILING MOUNTED COMBINATION MASS NOTIFICATION AND FIRE ALARM
SPEAKER WITH SEPARATE CEILING MOUNTED FIRE ALARM/MASS
NOTIFICATION STROBES. AMBER STROBE LENS IS FOR MASS
NOTIFICATION AND CLEAR STROBE LENS IS FOR FIRE ALARM SYSTEM.
SPEAKER TO BE SHARED BY FIRE ALARM AND MASS NOTIFICATION
SYSTEMS FOR AUDIBLE NOTIFICATION. (NUMBER INDICATES MINIMUM FIRE
ALARM STROBE CANDELA, "MN" ABOVE NUMBER INDICATES MINIMUM
MASS NOTIFICATION CANDELA. NOTE: MASS NOTIFICATION CANDELA
RATING SHOWN IS DERATED FOR AMBER STROBE LENS).
CEILING MOUNTED FIRE ALARM STROBE WITH CLEAR LENS
(NUMBER INDICATES MINIMUM CANDELA)
M.
LOCATE MASS NOTIFICATION DEVICES IN ACCORDANCE WITH
NFPA 72 FOR VISIBLE AND AUDIBLE NOTIFICATION DEVICES.
UPON ACTIVATION OF THE MASS NOTIFICATION SYSTEM,
TEMPORARILY DEACTIVATE FIRE ALARM SYSTEM AUDIBLE
SIGNALS DURING EMERGENCY VOICE MESSAGING. FIRE ALARM
VISUALS AND SIGNAL TRANSMISSION TO THE BASE FIRE
DEPARTMENT ARE TO REMAIN FUNCTIONAL. REACTIVATE THE
FIRE ALARM AUDIBLES AFTER THE MESSAGE IS COMPLETED.
N.
PROVIDE A TELEPHONE SYSTEM INPUT FOR THE MASS
NOTIFICATION SYSTEM TO ALLOW THE MASS NOTIFICATION
SPEAKERS TO BE UTILIZED FOR PA SYSTEM ANNOUNCEMENTS.
ELECTRICAL, MECHANICAL ROOMS, STORAGE ROOMS, LAUNDRY AREA:
0.15 GPM/SQ FT DENSITY OVER THE MOST REMOTE 3,000 SQUARE FEET,
WHICH MAY BE REDUCED IN ACCORDANCE WITH UFC 3-600-01 SECTION
4-2.3.3.3 WHEN UTILIZING QUICK RESPONSE SPRINKLERS, AND MAXIMUM
SPRINKLER SPACING OF 130 SQUARE FEET PLUS A HOSE STREAM
ALLOWANCE OF 500 GPM FOR AN ORDINARY HAZARD GROUP 1 OCCUPANCY.
POINT OF NEW CONNECTION TO EXISTING PIPING
DWELLING UNITS AND DORMITORY CORRIDORS: CALCULATIONS TO INCLUDE
A MAXIMUM OF FOUR MOST HYDRAULICALLY DEMANDING RESIDENTIAL
SPRINKLERS WITHIN A COMPARTMENT PER NFPA 13R. SPRINKLERS ARE TO BE
CALCULATED ACCORDING TO THE MANUFACTURER'S GUIDELINES
UTILIZING THE LARGEST SPRINKLER COVERAGE WITHIN A COMPARTMENT.
CALCULATION NODE POINT (2 NODES)
CALCULATION NODE POINT (1 NODE)
THERMAL DETECTOR (190° FIXED TEMPERATURE)
K.
R
RETURN DUCT DETECTOR (SUPPLIED BY FIRE ALARM
CONTRACTOR; INSTALLED BY MECHANICAL CONTRACTOR)
PROVIDE HANGERS AND SEISMIC BRACING AS REQUIRED PER NFPA 13 AND
UFC 4-010-01.
L.
S
SUPPLY DUCT DETECTOR (SUPPLIED BY FIRE ALARM
CONTRACTOR; INSTALLED BY MECHANICAL CONTRACTOR)
PROVIDE BLACK SCHEDULE 40 FOR 2" AND SMALLER PIPING, AND
SCHEDULE 10 FOR 2-1/2" AND LARGER PIPING. CONTRACTOR TO
CONDUCT WATER SUPPLY ANALYSIS TO UTILIZE THREADED FITTINGS FOR
SCHEDULE 40 PIPING AND ROLL GROOVED FITTINGS FOR SCHEDULE 10
PIPING. CPVC PIPING LISTED FOR FIRE PROTECTION USE MAY BE
UTILIZED IN RESIDENTIAL AND LIGHT HAZARD AREAS OF THE BUILDING
PER NFPA 13 AND NFPA 13R WHEN INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S REQUIREMENTS.
DRAWING REFERENCE KEY
MNCP
FAT
MASS NOTIFICATION SYSTEM CONTROL PANEL
WITH AUTONOMOUS CONTROL UNIT
FA101 FA111
SHEET NUMBER ON WHICH
DETAIL IS DRAWN
WATER FLOW TEST DATA
BY: JACOBS
LOCATION: NEAR SITE
STATIC PRESSURE: 72 PSI
OUTLETS FLOWING:
RESIDUAL PRESSURE: 70 PSI
1
M.
MONACO BT-X FIRE ALARM SIGNAL RADIO TRANSMITTER
OUTLET DIAMETER: 2.5"
LOC
2
TEST DATE: 00/00/09
PITOT PRESSURE: 60 PSI
LOCAL OPERATOR CONSOLE WITH MICROPHONE
OUTLET COEFFICIENT: 0.9
R
CONTROL RELAY
M
ADDRESSABLE MONITOR MODULE
C
ADDRESSABLE CONTROL MODULE
PROVIDE 16 AWG MINIMUM INITIATING DEVICE AND SIGNALING
LINE CIRCUITS.
PROVIDE STROBES AND SPEAKER/STROBES WITH WHITE
FACEPLATES THROUGHOUT THE BUILDING. FIRE ALARM
STROBES TO BE MARKED WITH "FIRE" AND MASS
NOTIFICATION STROBES TO BE MARKED WITH "ALERT" AS
SPECIFIED.
SPEAKERS SHOWN ON THE DRAWINGS ARE TO
BE SHARED BY THE FIRE ALARM AND MASS NOTIFICATION
SYSTEMS FOR AUDIBLE NOTIFICATION. PROVIDE ADDITIONAL
SPEAKERS AS NECESSARY TO MEET THE AUDIBILITY
REQUIREMENTS OF NFPA 72 SECTION 7.4.
PROVIDE QUICK RESPONSE CONCEALED PENDENT SPRINKLERS WITH WHITE
COVER PLATES FOR AREAS OTHER THAN DORMITORY ROOMS AND
ASSOCIATED CORRIDORS WITH TILE OR GYP BOARD CEILINGS. CENTER
SPRINKLERS IN THE LESSER DIMENSION OF CEILING TILE, AND ALIGN
SPRINKLERS WITH LIGHT FIXTURES FOR GYP BOARD CEILINGS. PROVIDE
RESIDENTIAL CONCEALED PENDENT SPRINKLERS WITH WHITE COVER PLATES
FOR ALL DORMITORY ROOMS AND ASSOCIATED CORRIDORS. IN ALL AREAS
WITHOUT SUSPENDED CEILINGS, PROVIDE QUICK RESPONSE BRASS UPRIGHT
SPRINKLERS.
LCD ANNUNCIATOR
H.
L.
J.
ANN
PROVIDE CONNECTIONS TO THE LIGHT AND POWER SERVICE
IN ACCORDANCE WITH 2007 NFPA 72.
HYDRAULICALLY CALCULATE THE WET PIPE FIRE SPRINKLER SYSTEM IN
ACCORDANCE WITH THE FOLLOWING NFPA 13, NFPA 13R, AND UFC
3-600-01 DESIGN CRITERIA:
OFFICE, ACADEMIC, AND COMMON AREAS: 0.10 GPM/SQ FT DENSITY
OVER THE MOST REMOTE 3,000 SQUARE FEET, WHICH MAY BE REDUCED
IN ACCORDANCE WITH UFC 3-600-01 SECTION 4-2.3.3.3 WHEN
UTILIZING QUICK RESPONSE SPRINKLERS, AND MAXIMUM SPRINKLER
SPACING OF 225 SQUARE FEET PLUS A HOSE STREAM ALLOWANCE OF
250 GPM FOR A LIGHT HAZARD OCCUPANCY.
MISCELLANEOUS
TAMPER SWITCH
G.
THESE DOCUMENTS DEPICT PERFORMANCE DESIGN ONLY.
PROVIDE COMPLETE DOCUMENTS FOR APPROVAL FROM
AFCEE, LOCAL FIRE DEPARTMENT, AND THE DESIGN/BUILD FIRE
PROTECTION ENGINEER. INCLUDE IN THE DRAWINGS ANY ADDITIONAL
EQUIPMENT NECESSARY TO COMPLETE THE INSTALLATION AND
COMPLY WITH APPLICABLE CODES AND AMENDMENTS.
TEST PORT
WATER FLOW SWITCH
DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER
THAN 3 FEET FROM AN AIR SUPPLY OR RETURN DIFFUSER.
K.
PRESSURE GAUGE
WITH GAUGE COCK
RE:2/F111A
F.
UTILIZE THE WATER FLOW TEST DATA BELOW FOR PREPARING HYDRAULIC
CALCULATIONS. VERIFY THAT THE PROPOSED SPRINKLER SYSTEMS DEMAND
CAN BE SATISFIED BY THE BASE WATER SUPPLY .
RELIEF VALVE
REFER TO
DRAWING/DETAIL NUMBER
SHEET NUMBER ON WHICH
CONDITION IS SHOWN
PROVIDE POWER LIMITED CIRCUITS.
PROVIDE CLASS "A", STYLE 6 SIGNALING LINE CIRCUITS.
PROVIDE CLASS "A", INITIATING DEVICE CIRCUITS. PROVIDE
CLASS "A", NOTIFICATION APPLIANCE CIRCUITS.
B
EXTERIOR WALL MOUNTED WEATHERPROOF MASS NOTIFICATION
LOUDSPEAKER
E.
J.
PROVIDE MANUAL WET CLASS I STANDPIPES WITH 2-1/2" HOSE VALVES
FOR ALL INTERIOR STAIRWELLS. THE STANDPIPES ARE TO BE SIZED TO
PROVIDE 100 PSI AT THE MOST HYDRAULICALLY REMOTE HOSE VALVE PER
NFPA 14 SECTIONS 7.7.3 AND 5.4.1.1 THROUGH THE FIRE DEPARTMENT
CONNECTION ONLY UTILIZING A FIRE DEPARTMENT PUMPER TRUCK.
WP
MOUNT THE OPERABLE PART OF MANUAL PULL STATIONS AT
48" AFF.
PROVIDE 16 AWG MINIMUM NOTIFICATION DEVICE CIRCUITS.
I.
CEILING MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER. SPEAKER
TO BE SHARED BY FIRE ALARM AND MASS NOTIFICATION SYSTEMS FOR
AUDIBLE NOTIFICATION.
D.
I.
H.
DISCHARGE FLOW: 1,300 GPM
PROVIDE COMPLETE DOCUMENTS FOR APPROVAL FROM AFCEE, LOCAL
FIRE DEPARTMENT, AND THE DESIGN/BUILD FIRE PROTECTION
ENGINEER. INCLUDE IN THE DRAWINGS ANY ADDITIONAL EQUIPMENT
NECESSARY TO COMPLETE THE INSTALLATION AND COMPLY WITH
APPLICABLE CODES AND AMENDMENTS.
N.
PROVIDE AUXILIARY DRAINAGE FOR ALL TRAPPED SECTIONS OF PIPE.
O.
PROVIDE ACCESS DOORS AND SIGNAGE WHERE ACCESS IS REQUIRED TO
CONCEAL SPRINKLER EQUIPMENT, VALVES, AND CONTROLS LOCATED IN
WALLS OR ABOVE CEILINGS AS APPROVED BY THE OWNER.
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
C. MOUNT ALL NOTIFICATION DEVICES WITH THE BOTTOM OF THE
STROBE LENS AT 80" AFF, OR 6" BELOW THE CEILING,
WHICHEVER IS LOWER. PER NFPA 72 AND UFAS.
COORDINATE THE LOCATION OF RISERS, DRAINS, TEST CONNECTIONS, AND
OTHER SPRINKLER SYSTEM COMPONENTS WITH ARCHITECTURAL,
STRUCTURAL, MECHANICAL AND ELECTRICAL PORTIONS OF THE BUILDING.
CHECK VALVE
CEILING MOUNTED MASS NOTIFICATION STROBE WITH AMBER LENS
(NUMBER INDICATES MINIMUM CANDELA)
B. RUN ALL WIRING IN MINIMUM 3/4" CONDUIT.
F.
G.
WALL MOUNTED COMBINATION MASS NOTIFICATION AND FIRE ALARM
SPEAKER/STROBE. CONTAINS AMBER STROBE LENS FOR MASS
NOTIFICATION AND CLEAR STROBE LENS FOR FIRE ALARM SYSTEM,
SPEAKER TO BE SHARED BY FIRE ALARM AND MASS NOTIFICATION
SYSTEMS FOR AUDIBLE NOTIFICATION. (NUMBER INDICATES MINIMUM FIRE
ALARM STROBE CANDELA, "MN" ABOVE NUMBER INDICATES MINIMUM
MASS NOTIFICATION CANDELA. NOTE: MASS NOTIFICATION CANDELA
RATING SHOWN IS DERATED FOR AMBER STROBE LENS).
PERFORM ALL DESIGN AND INSTALLATION WORK IN
ACCORDANCE WITH 2007 NFPA 72, UFC 3-600-01, UFC
4-021-01, UFAS, AND SPECIFICATIONS 275116 AND 283111.
THE TOTAL CALCULATED WATER DEMAND FOR THIS OCCUPANCY IS EQUAL
TO THE SUM OF THE SPRINKLER SYSTEM DEMAND PLUS THE COMBINED
HOSE STREAM ALLOWANCE REQUIRED PER UFC 3-600-01.
GATE VALVE
PRESSURE CONTROL VALVE
PROVIDE SLEEVES AND WALL PLATES FOR ALL PENETRATIONS THROUGH
WALLS OR FLOORS THAT MIGHT INCLUDE DRILLING THROUGH CONCRETE,
METAL, SHEETROCK, OR OTHER MATERIALS. FIELD VERIFY APPROXIMATE
WALL AND FLOOR PENETRATIONS SHOWN ON THE PLANS. SEAL ALL
PENETRATIONS IN RATED SEPARATION TO MEET THE MINIMUM FIRE RATING
OF THE WALL OR FLOOR IN ACCORDANCE WITH SPECIFICATION SECTION 078413.
A.
E.
UNION
NOTE BY SYMBOL REFERENCE
MN
XX
A
PROVIDE A COMPLETE COMBINATION/SPRINKLER STANDPIPE SYSTEM FOR
THE ENTIRE BUILDING IN ACCORDANCE WITH 2007 NFPA 13, 2007 NFPA
13R, 2007 NFPA 14, 2006 IBC, 2006 IFC, UFC 3-600-01, AND
SPECIFICATION SECTION 211313.
NOT FOR
CONSTRUCTION
Revision:
Date:
Scales:
12" = 1'-0"
Jacobs Project No.:
FDWD1301
Drawing Title:
FIRE PROTECTION
LEGEND & NOTES
Date:
OMNI-DIRECTIONAL FIRE ALARM ANTENNA
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
1
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
FP00
1
2
3
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
1
1 - FIRE PROTECTION A
1/4" = 1'-0"
3
By: Description:
3D FIRE PROTECTION A
B
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
FIRE PROTECTION
PLANS
2
1 - FIRE PROTECTION B
1/4" = 1'-0"
4
3D FIRE PROTECTION B
N
Date:
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
FP01
1
2
3
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
1
1 - FIRE PROTECTION C
1/4" = 1'-0"
2
By: Description:
3D FIRE PROTECTION C
B
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
FIRE PROTECTION
PLANS
N
Date:
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
FP02
1
3
2
DUCTWORK SYMBOLS
DESCRIPTION
SINGLE LINE
EQUIPMENT SYMBOLS
DOUBLE LINE
SYMBOL
4
KEYED NOTE
AD
AD
ACCESS DOOR
DUCT SMOKE DETECTOR
MISC. EQUIPMENT
BDD
BDD
BACKDRAFT DAMPER
NEW CONNECTION TO EXISTING
VARIABLE AIR VOLUME BOX
FIRE DAMPER
EQUIPMENT ABBREVIATIONS
SYMBOLS
DESCRIPTION
CARBON MONOXIDE MONITOR
CO
D
C
CARBON DIOXIDE (CO2) SENSOR
H
HUMIDISTAT
P
PRESSURE SENSOR
5
B
CH
FCU
FTR
P
VAV
BOILER
CHILLER
FAN COIL UNIT
FIN TUBE RADIATION
PUMP
VARIABLE AIR VOLUME BOX
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
SMOKE DAMPER
CHILLER
FC
FC
M
M
CD M
CD M
THERMOSTAT
(MOUNT 48" AFF)
T
FLEXIBLE CONNECTION
HORIZONTAL SPLIT-CASE PUMP
MOTORIZED DAMPER
CONTROL DAMPER
VD
VD
VOLUME DAMPER, MANUAL
SPMS
STATIC PRESSURE MEASURING STATION
S1
END-SUCTION PUMP
DUCT ELBOW WITH TURNING VANES
C
450
12x6
FTU
1
DUCT SECTION - SUPPLY AIR
DUCT SECTION - RETURN, OUTSIDE,
OR RELIEF AIR
N
NIGHT THERMOSTAT
ALARM STROBE
VERTICAL INLINE PUMP
SPMS
DIFFUSER, GRILLE OR REGISTER MARK
(REF SCHEDULE)
CFM
NECK SIZE (IF NOT ON SCHEDULE)
EQUIPMENT MARK
(REF SCHEDULE)
DETAIL DESIGNATION
LOCATOR/DESCRIPTOR
BOILER
DUCT SECTION - EXHAUST AIR
D
D
DUCT, INCLINED DROP
D
DRAWING WHERE DETAIL IS SHOWN
OR WHERE DETAIL IS REFERENCED
SECTION CUT
R
R
DUCT, INCLINED RISE
8" DIA
R
LOCATOR/DESCRIPTOR
DRAWING WHERE DETAIL IS SHOWN
OR WHERE DETAIL IS REFERENCED
8" DIA
FLEXIBLE DUCT - ROUND
18x12
12x12
18x12
12x12
8" DIA
12x12
12x12
DUCT TRANSITION
8" DIA
DUCT TRANSITION (SQUARE
OR RECTANGULAR TO
ROUND)
RECTANGULAR DUCT, SIZE IN
INCHES, FIRST DIMENSION IS
SIDE SHOWN (NET CLEAR INSIDE
DIMENSION)
B
ROUND DUCT, DIAMETER IN INCHES,
(NET CLEAR INSIDE DIMENSION)
24x10
12" DIA
By: Description:
TEMPERATURE SENSOR
(MOUNT 48" AFF)
TS
T
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
COMBINATION FIRE/SMOKE DAMPER
24x10
12" DIA
AIR FLOW IN DIRECTION OF ARROW
45° BRANCH TAKE-OFFS
CONICAL LATERAL BRANCH TAKE-OFFS
CEILING SUPPLY DIFFUSERS
CEILING RETURN GRILLE/REGISTER
CEILING EXHAUST GRILLE/REGISTER
Scales:
12" = 1'-0"
SIDEWALL SUPPLY GRILLE/REGISTER
Jacobs Project No.:
A
FDWD1301
Drawing Title:
SIDEWALL RETURN/EXHAUST
GRILLE/REGISTER
Mechanical Symbols
EXTRACTOR
DUCT TEE WITH SPLITTER DAMPER
Date:
DOOR UNDERCUT
DOOR LOUVER
UC
UC
L
L
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M00
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
VAV
01
VAV
02
Revision:
Date:
By: Description:
VAV
03
FTR
01A
FTR
03A
VAV
04
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
VAV
05
C
FTR
02A
Plan A - Cold/Arid
1
1/4" = 1'-0"
FTR
01B
FTR
04A
FCU
01B
2
Plan A - Cold/Arid
FTR
03B
B
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
Cold/Arid
FTR
02B
Plan B - Cold/Arid
3
1/4" = 1'-0"
FTR
04B
4
Plan B - Cold/Arid
N
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M01
1
3
2
4
5
FCU
01C
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
FTR
02C
FTR
03C
FTR
04C
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
FTR
01C
C
1
Plan C - Cold/Arid
1/4" = 1'-0"
2
By: Description:
Plan C - Cold/Arid
B
CH
P
P
B
Scales:
P
As indicated
Jacobs Project No.:
A
FDWD1301
Drawing Title:
Cold/Arid
P
3
Mechanical Yard - Cold/Arid
1/8" = 1'-0"
4
Mechanical Yard - Cold/Arid
N
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M02
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
VAV
01
VAV
02
Revision:
Date:
By: Description:
VAV
03
VAV
05
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
VAV
04
C
1
Plan A - Hot/Arid
1/4" = 1'-0"
2
Plan A - Hot/Arid
FCU
01B
FCU
02B
FCU
04B
B
Scales:
1/4" = 1'-0"
Jacobs Project No.:
FCU
03B
A
FCU
05B
FDWD1301
Drawing Title:
Hot/Arid
N
3
Plan B - Hot/Arid
1/4" = 1'-0"
4
Plan B - Hot/Arid
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M03
1
3
2
4
5
FCU
01C
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
FCU
03C
FCU
04C
FCU
05C
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
FCU
02C
C
1
Plan C - Hot/Arid
1/4" = 1'-0"
2
Plan C - Hot/Arid
CH
B
P
By: Description:
P
B
P
Scales:
As indicated
Jacobs Project No.:
A
FDWD1301
Drawing Title:
Hot/Arid
P
3
Mechanical Yard - Hot/Arid
1/8" = 1'-0"
4
Mechanical Yard - Hot/Arid
N
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M04
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
VAV
01
VAV
02
Revision:
Date:
By: Description:
VAV
03
VAV
05
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
VAV
04
C
1
Plan A - Hot/Humid
1/4" = 1'-0"
2
Plan A - Hot/Humid
FCU
01B
FCU
02B
FCU
04B
B
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
FCU
03B
FDWD1301
Drawing Title:
FCU
05B
Hot/Humid
N
Plan B - Hot/Humid
3
1/4" = 1'-0"
4
Plan B - Hot/Humid
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M05
1
3
2
4
5
FCU
01C
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
Revision:
Date:
FCU
03C
FCU
04C
FCU
05C
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
FCU
02C
C
1
Plan C - Hot/Humid
1/4" = 1'-0"
2
By: Description:
Plan C - Hot/Humid
CH
B
P
CH
P
B
Scales:
As indicated
P
P
Jacobs Project No.:
A
FDWD1301
Drawing Title:
Hot/Humid
P
N
3
Mechanical Yard - Hot/Humid
1/8" = 1'-0"
4
Mechanical Yard - Hot/Humid
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M06
BASIS OF DESIGN
D
MARK
01B
01C
02B
02C
03B
03C
04B
04C
05B
05C
LOCATION
3
2
MANUFACTURER
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
JOHNSON CONTROLS
MODEL
FLX-03
FLX-03
FLX-03
FLX-03
FLX-03
FLX-03
FLX-03
FLX-03
MOTOR DATA
AIR
FLOW
ESP
(CFM) (IN-WG)
TYPE
VERTICAL CABINET
0.00
VERTICAL CABINET
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
HOTEL STYLE
240
0.00
6,700
6,700
6,700
6,700
6,700
6,700
6,700
6,700
5,200
5,200
5,200
5,200
5,200
5,200
5,200
5,200
DB
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
75.0 °F
WB
62.9 °F
62.9 °F
62.9 °F
62.9 °F
62.9 °F
62.9 °F
62.9 °F
62.9 °F
BASIS OF DESIGN
C
MARK
01
01
01
02
02
02
03
03
03
04
04
04
05
05
05
LOCATION
SERVING
B
MARK
01A
01B
01C
02A
02B
02C
03A
03B
03C
04A
04B
04C
SERVING
MANUFACTURER
BASIS OF DESIGN
MARK
R1
MANUFACTURER
AIR MATE
MODEL
E240V
E1
AIR MATE
E240V
BASIS OF DESIGN
MARK
S1
MANUFACTURER
AIR MATE
MODEL
A140
MODEL
RETURN AND EXHAUST AIR DEVICE SCHEDULE
DIFFUSER
SLOT
REGISTER/GRILL
LENGTH # OF
SLOT NOMINAL DUCT
SIZE
(FT)
SLOTS WIDTH
MODULE SIZE NECK SIZE
DAMPER
SEE PLANS
SEE PLANS
SUPPLY AIR DEVICE SCHEDULE
DIFFUSER
SLOT
REGISTER/GRILL
LENGTH # OF
SLOT NOMINAL DUCT
SIZE
(FT)
SLOTS WIDTH
MODULE SIZE NECK SIZE
DAMPER
SEE PLANS
A
S2
AIR MATE
140
MANUFACTURER MODEL
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
TITUS
DESV
FIN TUBE RADIATOR SCHEDULE (FTR)
ENCLOS ENCLOSU
URE
RE
FINNED
LENGTH HEIGHT LENGTH
ELEMENT
ROWS
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
2
0' - 0"
24"
48"
BASIS OF DESIGN
SEE PLANS
FAN COIL UNIT SCHEDULE (FCU) Cold/Arid
COOLING COIL
LAT
FLOW
(GPM)
DB
WB
EWT
LWT
55.0 °F
44.0 °F
54.0 °F
55.0 °F
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
55.0 °F
53.2 °F
1.34
44.0 °F
54.0 °F
EAT
TOTAL SENSIBLE
(BTU/H)
(BTU/H)
EWT
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
LWT
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
EAT
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
GPM
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
5
HEATING COIL
HEATING
WPD CAPACITY
(FT-H2O) (BTU/H)
0.00
0.00
3.40
7,000
3.40
7,000
3.40
7,000
3.40
7,000
3.40
7,000
3.40
7,000
3.40
7,000
3.40
7,000
VAV SCHEDULE (VAV) Cold/Arid
SIZE
CFM
STATIC PRESSURE (in-wg)
DROP
INLET
OUTLET
MAX
MIN
INLET DOWN THRU BOX
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
8"
12"x10"
350
145
1.00
0.25
0.00
8"
12"x10"
350
145
1.00
0.25
0.00
8"
12"x10"
350
145
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
5"
12"x8"
350
80
1.00
0.25
0.00
TOTAL
BTU/h
0
0
0
0
0
0
0
0
0
0
0
0
BORDER
TYPE
GYPSUM
BOARD
GYPSUM
BOARD
4
EAT
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
68.0 °F
LAT
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
95.0 °F
FLOW
(GPM)
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
ELECTRICAL DATA
EWT
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
NC LEVELS
RAD.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
DISCH.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
CFM
80
80
80
80
80
80
145
145
145
80
80
80
80
80
80
CAPACITY
(BTU/H)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
EAT
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
0.0 °F
LWT
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
160.0 °F
WPD
(FT-H2O)
0.00
0.00
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.20
HP
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
V
0
0
115
115
115
115
115
115
115
115
ELECTRIC REHEAT COIL DATA
APD
(in-wg)
LAT
KW
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
0.0 °F
0.00
0.0
V
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Ph
0
0
1
1
1
1
1
1
1
1
Hz
0
0
60
60
60
60
60
60
60
60
PH
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
OPERATING
WEIGHT
0
0
0
0
0
0
0
0
0
0
Hz
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
REMARKS
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
By: Description:
REMARKS
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
1
NOTES
REMARKS
Scales:
BORDER
TYPE
GYPSUM
BOARD
GYPSUM
BOARD
REMARKS
Jacobs Project No.:
FDWD1301
Drawing Title:
Schedules
Date:
May 11, 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
M07
1
VALVE SYMBOLS
PITCH DOWN IN DIRECTION OF ARROW
VALVE IN CENTER DROP
DIRECTION OF FLOW
VALVE IN RISE
GENERAL NOTES
MISCELLANEOUS
RECESSED FLOOR CLEANOUT
A.
HOSE BIBB/WALL HYDRANT
FLOOR DRAIN
PIPE GUIDE
SOLENOID VALVE
FLOOR DRAIN WITH P-TRAP
CONCENTRIC REDUCER
TWO-WAY CONTROL VALVE
P-TRAP
B. COORDINATE THE EXACT LOCATION OF FLOOR DRAINS WITH THE ARCHITECTURAL DRAWINGS
AND MECHANICAL EQUIPMENT LOCATIONS PRIOR TO INSTALLATION OF DRAINS. PROVIDE A
RADIUS AROUND THE FLOOR DRAIN THAT SLOPES TOWARD THE FLOOR DRAIN FROM THE
FINISHED FLOOR ELEVATION TO A TOP OF DRAIN ELEVATION BETWEEN 1/2" AND 3/4"
BELOW FINISHED FLOOR. THE RADIUS AND RATE OF SLOPE IS TO BE FIELD COORDINATED.
ECCENTRIC REDUCER
THREE-WAY CONTROL VALVE
PLUMBING FIXTURES
C. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES PRIOR TO EACH CONCRETE POUR.
S
GAS METER
SAFETY VALVE OR PRESSURE RELIEF VALVE
BRANCH - TOP CONNECTION
MANUAL BALANCING VALVE
BRANCH - BOTTOM CONNECTION
AUTOMATIC BALANCING VALVE
TEMPERATURE WELL
RISE OR DROP IN PIPE
RISER DOWN (ELBOW)
DCBFP
RPBFP
P
1
DOUBLE CHECK BACKFLOW PREVENTER
REDUCED PRESSURE BACKFLOW PREVENTER
RISER DESIGNATION "P": DENOTES SANITARY WASTE
AND VENT RISER DIAGRAM OR DOMESTIC COLD AND
HOT WATER RISER DIAGRAM
ANGLE GATE VALVE
PROCESS COMPRESSED AIR CONNECTION
BLIND FLANGE
DIAPHRAGM VALVE
UNION (SCREWED)
QUICK ACTION VALVE
ORIFICE UNION
OS&Y VALVE
FLANGED CONNECTION
DEBRIS VACUUM CONNECTION
1
OS&Y VALVE WITH SUPERVISORY SWITCH
DRAWING NOTE REFERENCE
FLANGED VALVE (GATE VALVE SHOWN)
STRAINER WITH BLOWDOWN VALVE
FLEX PIPE
ORIFICE FLOW PLATE
DRAWING/DETAIL REFERENCE KEY
BELLOWS CONNECTION
(DOUBLE SPHERE NEOPRENE TYPE)
THERMOMETER
PIPING TYPES
PRESSURE GAGE WITH COCK
PS
SANITARY SEWER
FLOW SWITCH
SANITARY VENT
PRESSURE SWITCH
DOMESTIC COLD WATER
MANUAL AIR VENT
DOMESTIC HOT WATER (110°F)
AUTOMATIC AIR VENT
DOMESTIC HOT WATER RETURN
PUMP
STEAM TRAP
M
140°
DOMESTIC HOT WATER (140°F)
NPW
NON POTABLE WATER
TP
TRAP PRIMER
LINE/WALL CLEANOUT
D
DRAIN (AHU CONDENSATE)
WATER METER
G
NATURAL GAS
CONDENSATE DRAIN
CD
A
AIR OUTLET VALVE
A
COMPRESSED AIR
DV
DEBRIS VACUUM (CLEANING)
WELDED CONNECTION
VAC
VACUUM
FLANGED CONNECTION
BA
BREATHING AIR
B
SOLDERED CONNECTION
THREADED OR "PRESS" CONNECTION
BELL & SPIGOT CONNECTION
AHW
AIRCRAFT HOT WATER WASH WATER
INW
INDUSTRIAL WASTE
RCW
RECYCLED WASH WATER
X
X
AAA
DOUBLED WALL PIPING - "AAA" DENOTED TYPE
AAA
EXISTING PIPE - "AAA" DENOTES TYPE
AAA
SHEET NUMBER ON WHICH
DETAIL IS DRAWN
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
By: Description:
WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORY,
AMERICAN CODES, ANSI, ASME, ASA, ASHRAE, ASTM, ARI, NEC, NFPA, SMACNA, OR THE
STATE FIRE INSURANCE REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER OR NOT
INDICATED ON THE DRAWINGS.
I.
PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT IN OPERATING
CONDITION WITHOUT OBJECTIONABLE VIBRATION OR NOISE.
J.
PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC).
K. VERIFY AND DOCUMENT EXISTING CONDITIONS AND DIMENSIONS ON THE JOB SITE PRIOR
TO STARTING ANY WORK.
L.
2
P-101 P-201
DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES.
M. INSTALL PIPING TO PROVIDE THE MAXIMUM POSSIBLE CLEAR HEIGHT UNDERNEATH.
MAINTAIN A MINIMUM OF 6 INCHES ABOVE FINISHED CEILING TO PROVIDE CLEARANCE FOR
LIGHTING FIXTURES.
N. CONTRACTOR TO MAKE ALL FINAL CONNECTIONS TO EQUIPMENT.
O. VENT TERMINALS SHALL EXTEND A MINIMUM OF 6" ABOVE THE FINISHED ROOF AND SHALL
BE LOCATED A MINIMUM OF 10 FEET HORIZONTALLY FROM ANY DOOR, OPERABLE WINDOW,
OR OTHER AIR INTAKE OF THE BUILDING OR ADJACENT BUILDING UNLESS THE VENT
TERMINAL IS AT LEAST 2 FEET ABOVE THE TOP OF SUCH OPENING.
P. PROVIDE SYSTEM IN ACCORDANCE WITH 2006 ICC INTERNATIONAL PLUMBING CODE.
Q. ALL VENT LINES ARE TO RISE VERTICALLY (45° ANGLE OR GREATER FROM HORIZONTAL) TO
A MINIMUM OF 6" ABOVE THE HIGHEST FLOOD RIM OF THE HIGHEST FIXTURE SERVED BY
THE VENT.
R. SLOPE SANITARY SEWER PIPE SMALLER THAN 3'' AT 1/4'' PER FOOT AND PIPE 3'' AND
LARGER AT 1/8'' PER FOOT. ALL SLOPES ARE IN THE DIRECTION OF FLOW.
S. PROVIDE BRACING FOR ALL PIPING AND EQUIPMENT AS REQUIRED BY UFC 4-010-01.
ENERGY CODE COMPLIANCE
THE MECHANICAL AND PLUMBING EQUIPMENT IN THESE DRAWINGS ARE IN COMPLIANCE
WITH ASHRAE 90.1-2004 AND THE FEDERAL ENERGY MANAGEMENT PROGRAM (FEMP).
PUMPED FLUID - "AAA" DENOTED TYPE
P-AAA
SOLVENT CONNECTION
RE:2/P-201
REFER TO
DRAWING/DETAIL NUMBER
SHEET NUMBER ON WHICH
CONDITION IS SHOWN
911 Central Parkway N., Suite 425 San Antonio, TX 78323
G. ARRANGE WITH AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE
CONNECTIONS. VERIFYING LOCATIONS AND ARRANGEMENTS AND PAYING ALL CHARGES,
INCLUDING INSPECTIONS.
WATER SHOCK ABSORBER
FLOAT VALVE
NOT FOR
CONSTRUCTION
H. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT
INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, PLUMBING WORK, ELECTRICAL
WORK, AND BUILDING STRUCTURE WILL BE AVOIDED.
POINT OF CONNECTION TO EXISTING
TEMPERATURE & PRESSURE PORT
FLEX CONNECTION
E. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS OR
SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES, OR REGULATIONS OF
FEDERAL, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE
BIDS ARE RECEIVED.
BREATHING AIR CONNECTION
ANGLE GLOBE VALVE
CAPPED PIPE
D. FURNISH ACCESS DOORS FOR INSTALLATION IN WALLS AND CEILINGS WHERE ACCESS IS
REQUIRED TO CONCEALED PLUMBING EQUIPMENT, VALVES, CONTROLS, AND OTHER
DEVICES.
F.
PROCESS VACUUM CONNECTION
RISER UP (ELBOW)
FS
REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION.
GATE VALVE W/ 3/4" HOSE THREAD ADAPTER
BRANCH - SIDE CONNECTION
C
5
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
PIPE ANCHOR
D
4
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
PLUMBING SYMBOLS
PIPING SYMBOLS
3
2
X
X
EXISTING PIPE TO BE REMOVED - "AAA" DENOTES TYPE
BELOW FLOOR PIPE - "AAA" DENOTES TYPE
AAA
VALVE SYMBOLS
CHECK VALVE (NON SLAM)
PLUG VALVE
X X X X
X X
GLOBE VALVE
EQUIPMENT SYMBOLS
X X
GATE VALVE
12" = 1'-0"
EXISTING EQUIPMENT TO BE REMOVED
Scales:
EXISTING EQUIPMENT TO REMAIN
Jacobs Project No.:
X X X X
A
FDWD1301
Drawing Title:
PRESSURE REDUCING VALVE (PRV)
BUTTERFLY VALVE
BALL VALVE
NEEDLE VALVE
NEW EQUIPMENT
PLUMBING LEGEND
& NOTES
VALVE IN DROP
Date:
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
P00
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
L-1
501 North Broadway, St. Louis, Missouri 63102-2121
L-1
WC-1
WC-1
T-1
T-1
Revision:
Date:
T-1
WMC-1
By: Description:
T-1
WC-1
WC-1
KS-1
L-1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
L-1
C
1
1 - Plumbing - A
1/4" = 1'-0"
2
3D Plumbing - A
WMC-1
T-1
B
T-1
L-1
L-1
WC-1
T-1
WC-1
WC-1
KS-1
L-1
L-1
WC-1
Scales:
T-1
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
PLUMBING FLOOR
PLANS
3
1 - Plumbing - B
1/4" = 1'-0"
4
3D Plumbing - B
N
Date:
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
P01
1
3
2
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
D
WMC-1
KS-1
Revision:
Date:
T-1
T-1
WC-1
WC-1
L-1
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
L-1
C
L-1
L-1
WC-1
WC-1
T-1
T-1
1
B
1 - Plumbing - C
1/4" = 1'-0"
2
MARK
KS-1
L-1
T-1
WC-1
WMC-1
By: Description:
PLUMBING FIXTURE ROUGH-IN SCHEDULE
CONNECTION SIZE
DESCRIPTION
CW
HW
SAN
1/2"
1/2"
2"
1/2"
1/2"
1 1/4"
1/2"
1/2"
2"
1/2"
4"
1/2"
1/2"
2"
3D Plumbing - C
VENT
0"
0"
0"
0"
Scales:
1/4" = 1'-0"
Jacobs Project No.:
A
FDWD1301
Drawing Title:
PLUMBING FLOOR
PLANS
N
Date:
11 MAY 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
P02
1
3
2
4
5
NOT FOR
CONSTRUCTION
?
501 North Broadway, St. Louis, Missouri 63102-2121
GB7
GB1
D
GB9
911 Central Parkway N., Suite 425 San Antonio, TX 78323
Revision:
Date:
By: Description:
GB10
GB8
GB11
GB6
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
GB4
C
GB5
GB3
1
UNIT A - CONCRETE
1/4" = 1'-0"
3
UNIT A - CONCRETE
24 x 24
24 x 24
B
Scales:
1/4" = 1'-0"
24 x 24
FDWD1301
Jacobs Project No.:
A
Drawing Title:
2
UNIT B - CONCRETE
1/4" = 1'-0"
4
CONCRETE PLANS/
AXONS (plan A, B and
axon)
UNIT B - CONCRETE
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
S01
1
3
2
4
5
24 x 24
24 x 24
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
24 x 24
Revision:
Date:
24 x 24
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
24 x 24
24 x 24
C
24 x 24
1
UNIT C - CONCRETE
1/4" = 1'-0"
3
UNIT C - CONCRETE
B
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
2
STAIRS - CONCRETE
1/4" = 1'-0"
4
STAIRS - CONCRETE
CONCRETE PLANS/
AXONS (communal
area and stairs)
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
S02
1
2
3
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
1
UNIT A - STEEL
1/4" = 1'-0"
3
By: Description:
UNIT A - STEEL
B
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
2
UNIT B - STEEL
1/4" = 1'-0"
4
STEEL PLANS/
AXONS (plan A, B and
axon)
UNIT B - STEEL
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
S03
1
2
3
4
5
NOT FOR
CONSTRUCTION
911 Central Parkway N., Suite 425 San Antonio, TX 78323
D
501 North Broadway, St. Louis, Missouri 63102-2121
Revision:
Date:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
C
1
UNIT C - STEEL
1/4" = 1'-0"
3
By: Description:
UNIT C - STEEL
B
Scales:
1/4" = 1'-0"
FDWD1301
Jacobs Project No.:
A
Drawing Title:
STAIRS - STEEL
2
1/4" = 1'-0"
4
STEEL PLANS/
AXONS (communal
area and stairs)
STAIRS - STEEL
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
S04
1
3
2
4
5
NOT FOR
CONSTRUCTION
BEAM SCHEDULE - UNIT A
GB1
GB3
GB4
GB5
GB6
GB6
GB6
GB6
GB7
GB8
GB9
GB9
GB10
GB10
GB11
REINFORCING STEEL
NO.
SIZE
TYPE
REMARKS
NO.
SIZE
STIRRUPS
TYPE
SPACING (EACH END U.N.O.)
911 Central Parkway N., Suite 425 San Antonio, TX 78323
501 North Broadway, St. Louis, Missouri 63102-2121
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
Revision:
Date:
C
BEAM SCHEDULE - UNIT B
MARK
GB12
GB13
GB16
GB19
GB20
GB20
GB21
GB21
SIZE
W" X D"
REINFORCING STEEL
NO.
SIZE
TYPE
REMARKS
NO.
SIZE
By: Description:
AIR FORCE CENTER FOR ENGINEERING AND THE
ENVIRONMENT (AFCEE)
FACILITIES DYNAMIC PROTOTYPES DESIGN FOR
DORMITORIES
D
MARK
SIZE
W" X D"
STIRRUPS
TYPE
SPACING (EACH END U.N.O.)
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
24 x 24
B
Scales:
FDWD1301
Jacobs Project No.:
A
Drawing Title:
BEAM SCHEDULE
N
Date:
06 MARCH 2009
Designed By: Designer
Drawn By: Author
Checked By: Checker
Drawing No.:
S05
Download