Section Updated 04 / 2016 Modular Metering Section 2 Mini Mod III Nomenclature .....................................................................2-2 Mini Mod III—Ring Type and Ringless................................................2-3 Mini Mod III—Tenant Main Circuit Breakers....................................2-4 Mini Mod III—Factory Installed Accessories ...................................2-5 Mini Mod III—Field Installed Accessories .........................................2-6 Meter Mod III Nomenclature .................................................................2-7 Meter Mod III—How to Order; Short Circuit Ratings ..................2-8 Meter Mod III—Modular Metering Series Ratings ........................2-9 Meter Mod III—Main Breaker Modules, Single-Phase and Three-Phase .....................................................2-11 Factory Installed Accessories.........................................................2-13 Meter Mod III—Main Fusible Modules, Single-Phase and Three-Phase .....................................................2-14 Factory Installed Accessories.........................................................2-15 Meter Mod III—Main Fusible with Pull Box and Main Lug Modules Single-Phase and Three-Phase .....................................................2-16 Factory Installed Accessories.........................................................2-17 Meter Mod III—Main Pull Box Modules and Accessories Single-Phase and Three-Phase .....................................................2-18 Meter Mod III—Meter Stack Modules, Single-Phase Plus Accessories ......................................................2-19 Meter Mod III—Meter Stack Modules, Three-Phase Plus Accessories .......................................................2-23 Meter Mod III—Meter Stack Modules, Phase Balancing...................................................................................2-24 Meter Mod III—Applications Where Center-Feeding Main Module is Required................................2-25 Mini Mod III—Enclosure Knockout Dimensions..........................2-26 Meter Mod III—Enclosure Knockout Dimensions ......................2-27 Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-1 Modular Metering Section 2 Mini Mod III Nomenclature Product Number Systemsi Product Number Guide for Mini Mod III (Product number for illustrative purposes only) T MM 6 6 20 R F Special MEG Approved GE Identification Type MM = Mini Mod™ Ring Type MMR = Mini Mod™ Ringless Horizontal Bus Rating 2 = 200A 4 = 400A 6 = 600A Enclosures R = Type 3R rainproof Socket Rating 12 = 125A 20 = 200A Socket Positions 1-6 2-2 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Mini Mod III Basic Devices Ring-Type and Ringless Product Features —UL Listed (Panelboards No. 67) —Indoor/Outdoor Construction —Ring-Type and Ringless Meter Sockets —Bondable Neutral, Strap Included —11-inch Mounting Z Rail Included —Swing Away Mounting Feet Factory Installed —Underground, incoming feed only TMM4412R Ring Type Socket1 No. of Sockets Main Ampere Rating 125 A 125 A 125 A 125 A 125 A 200 A 200 A 200 A 2 3 4 5 6 2 3 4 200 400 400 600 600 400 600 600 (1) 6 -300 (1) 6 -600 or (2) 2/0 -250 (1) 6 -600 or (2) 2/0 -250 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 6-2/0 4-300 4-300 4-300 4-300 4-300 4-300 4-300 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 TMM2212R2 TMM4312R TMM4412R TMM6512R TMM6612R TMM4220R TMM6320R TMM6420R 200 A 5 600 (2) 250 - 500 4-300 14-4 TMM6520R 200 A 6 600 (2) 250 - 500 4-300 14-4 TMM6620R Socket Amps Main Wire Size AWG/kcmil Cu/A Service Ground Equipment Ground Standard Product Number MEG Product Number3 TMM2212RF2 TMM4312RF TMM4412RF TMM6512RF TMM6612RF Use TMM6320RF TMM6320RF TMM6420RF Use Meter Mod III or Ringless Use Meter Mod III or Ringless Ringless Type Socket4 Socket Amps No. of Sockets Main Ampere Rating Main Wire Size AWG/kcmil Cu/Al Service Ground Equipment Ground 2 3 4 5 6 2 3 4 5 6 200 400 400 600 600 400 600 600 600 600 (1) 6 -300 (1) 6 -600 or (2) 2/0 -250 (1) 6 -600 or (2) 2/0 -250 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 (2) 250 - 500 6-2/0 4-300 4-300 4-300 4-300 4-300 4-300 4-300 4-300 4-300 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 125 A 125 A 125 A 125 A 125 A 200 A 200 A 200 A 200 A 200 A Short Circuit Ratings — UL Listed All Mini Mod IIIs are UL listed for the short circuit rating at 240 Vac maximum in rms symmetrical amperes of the tenant breaker installed, selected from table below. The short circuit rating is limited to the lowest interrupting rating of any tenant breaker installed. Replacement breakers shall be of the same manufacturer and type and shall have an interrupting rating equal to or greater than the interrupting rating of any tenant breaker presently installed in this device. Tenant Main Breaker Frame TMQD TMQL THQD THHQL TQD THQL Standard Product Number TMMR2212R2 TMMR4312R TMMR4412R TMMR6512R TMMR6612R TMMR4220R TMMR6320R TMMR6420R TMMR6520R TMMR6620R Horned Bypass Product Number5 TMMR2212RHB2 TMMR4312RHB TMMR4412RHB TMMR6512RHB TMMR6612RHB TMMR4220RHB TMMR6320RHB TMMR6420RHB TMMR6520RHB TMMR6620RHB MEG Product Number3 TMMR2212RF2 TMMR4312RF TMMR4412RF TMMR6512RF TMMR6612RF TMMR4220RF TMMR6320RF TMMR6420RF TMMR6520RF TMMR6620RF 1One snap-type, aluminum sealing ring(TSR5) per socket included 2May be fed from overhead. Use hub TC300. 3Units with “F” suffix have an additional cotter pin that has been added to the meter socket assembly to keep meter socket from detaching from base. These are required in all MEG areas as of January 2016. 4Includes factory installed fifth jaw. 5Units with “HB” suffix have a factory installed horn bypass included. UL Listed AIC Rating 100,000 42,000 22,000 22,000 10,000 10,000 GE breakers rated 10,000 AIC or greater when installed on the load side of the Mini Mod III are protected for the interrupting rating per the UL Listing marked on the tenant breaker. Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-3 Modular Metering Section 2 Mini Mod III Tenant Main Circuit Breakers Tenant Main Circuit Breakers For 125 Amp Sockets Ampere Rating 10,000 AIC Product Number 22,000 AIC Product Number 42,000 AIC Product Number 60 70 80 90 100 110 125 1251 THQL2160 THQL2170 THQL2180 THQL2190 THQL21100 THQL21110 THQL21125 TMQL21125SF THHQL2160 THHQL2170 THHQL2180 THHQL2190 THHQL21100 THHQL21110 THHQL21125 – TMQL2160 TMQL2170 TMQL2180 TMQL2190 TMQL21100 – TMQL21125 – THQL, THHQL 1Sub-feed lug kit, no overcurrent protection. Tenant Main Circuit Breakers For 200 Amp Sockets Ampere Rating 10,000 AIC Product Number 22,000 AIC Product Number 100,000 AIC Product Number 60 70 80 90 100 125 150 175 200 – – – – TQD22100 TQD22125 TQD22150 TQD22175 TQD22200 – – – – THQD22100 THQD22125 THQD22150 THQD22175 THQD22200 TMQD22060 TMQD22070 TMQD22080 TMQD22090 TMQD22100 TMQD22125 TMQD22150 TMQD22175 TMQD22200 Tenant Main Lug Wire Sizes (AWG/kcmil) Type THQL, THHQL TMQL TMQD TQD, THQD TMQL TQD, THQD Ampere Rating Copper Aluminum 60 70-100 110-125 60-125 60-90 100-150 175-225 100-200 8-3 6-1/0 2-2/0 10-1/0 6-1/0 6-4/0 1/0-300 1-300 8-2 4-1/0 2-2/0 10-1/0 6-1/0 6-4/0 1/0-300 1-300 TMQD 2-4 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Mini Mod III Accessories Factory Installed Mini Mod III Factory Installed Lug Kit Main Mini Mod TMM2212R, TMM2212RF TMMR2212R, TMMR2212RF, TMMR2212RHB TMM4312R, TMM4312RF TMMR4312R, TMMR4312RF, TMMR4312RHB TMM4412R, TMM4412RF TMMR4412R, TMMR4412RF, TMMR4412RHB TMM6512R, TMM6512RF TMMR6512R, TMMR6512RF, TMMR6512RHB TMM6612R, TMM6612RF TMMR6612R, TMMR6612RF, TMMR6612RHB TMM4220R TMMR4220R, TMMR4220RF, TMMR4220RHB TMM6320R, TMM6320RF TMMR6320R, TMMR6320RF, TMMR6320RHB TMM6420R, TMM6420RF TMMR6420R, TMMR6420RF, TMMR6420RHB TMM6520R TMMR6520R, TMMR6520RF, TMMR6520RHB TMM6620R TMMR6620R, TMM6620RF, TMMR6620RHB Phase Neutral Amp. Rating Wire Size Wire Size 125 #6-300 #6-300 125 (1) 2/0-600 or (2) #6-250 (2) 250-500 GE Lug Kit Product Number Lugs Per Kit (1) 2/0-600 or (2) #6-250 TMMLK1 1 lug/kit, 1 lug per phase, 2 hole lug (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase 125 200 Mini Mod III Factory Optional Lug Kit and Optional Compression Lug Kit Main Mini Mod Amp. Rating TMM4312R, TMM4312RF 125 TMMR4312R, TMMR4312RF, TMMR4312RHB 125 TMM4412R, TMM4412RF 125 TMMR4412R, TMMR4412RF, TMMR4412RHB 125 TMM6512R, TMM6512RF 125 TMMR6512R, TMMR6512RF, TMMR6512RHB 125 TMM6612R, TMM6612RF 125 TMMR6612R, TMMR6612RF, TMMR6612RHB 125 TMM4220R 200 TMMR4220R, TMMR4220RF, TMMR4220RHB 200 TMM6320R, TMM6320RF 200 TMMR6320R, TMMR6320RF, TMMR6320RHB 200 TMM6420R, TMM6420RF 200 TMMR6420R, TMMR6420RF, TMMR6420RHB 200 TMM6520R 200 TMMR6520R, TMMR6520RF, TMMR6520RHB 200 TMM6620R 200 TMMR6620R, TMM6620RF, TMMR6620RHB 200 Rev. 11/13 Data subject to change without notice www.geindustrial.com Wire Size Phase GE Lug Kit Product Number (3) #4-300 (2) 250-500 (3) #4-300 (2) 250-500 (3) #4-300 (2) 250-500 (3) #4-300 (2) 250-500 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 (3) #4-300 (1) 2/0-600 or (2) #6-250 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 TMPAL40 TMPAL30 Wire Size GE Lug Kit Product Number Compression TMM6CLL BuyLog™ Catalog Lugs Per Kit 2 studs per phase, double stack for up to 2 conductors per phase, kit includes 3 lug landing pads (1 kit per device) 2-5 Modular Metering Section 2 Mini Mod III Accessories Field Installed Accessories - Field Installed Product Number Description Semi-Flush Kits -125A Sockets -2 gang -3 and 4 gang -5 and 6 gang -2 gang -200A Sockets -3 and 4 gang -5 and 6 gang Compression Lug Landing Kit -600 amp Includes 3 pads each with 2 threaded stud connections (and hardware) for compression or mechanical lugs with NEMA 2-hole bolt configuration (lugs not furnished). Not suitable for 2-gang By-pass Kits Manual Slider-Type (Ring Type Only)1 -125 amp top socket for 2, 3, 5 and 6 gang -125 amp for all other sockets -200 amp for all sockets Jumper Straps Type1 (use with TMCA) Cover Including Jumper Strap Type-fits all (Ring Type Only)3 Horn-Type-fits all (Ringless Only)1 Fifth Jaw Kits -Bused; 3, 6, or 9 o'clock mounting: Order two for fifth and sixth jaw. Not suitable for 2-gang ring type -Isolated; 3 or 9 o'clock mounting Sealing Rings -Screw-Type, Aluminum -Snap Type, Stainless Steel -Screw and Lock-Type, Aluminum -Snap-Type, Aluminum (Standard) Steel Meter Socket Covers Blank (fits bottom position only) -125 Amp -200 Amp Ringless (Field -converts ring-type to ringless) -125 amp top socket for 2 and 3 gang -125 amp for all other sockets -200 amp for all sockets Lexan Meter socket Cover Plate (without tabs) Lexan Meter Socket Cover Plate Equipment Ground Bar, (6) 6-2/0 Individual Meter Socket Barrier Kit (includes 6) Mounting Z-Rail, 4-foot Lug Kit for (3) 4/0 cable TMM12SF2 TMM12SF4 TMM12SF6 TMM20SF2 TMM20SF4 TMM20SF6 TMM6CLL TMBPM12TA TMBPM12A TMBPM20A2 TMBPJ204 TMBPC204 TMBPH20A TM5JA TM5JUA TSR1 TSR3 TSR4 TSR5 TMCB12B TMCB20B TMCR12T TMCR12 TMCR20 TMCA TMCP TMEG TMBR TMZR TMPAL40 1100 amps continuous. 2For top socket on TMM4220R, order TMBPM20TA. 3200 amps continuous. 4Not UL Listed. 2-6 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Nomenclature Product Number Systemsi Product Number Guide for Meter Stack Modules (Product number for illustrative purposes only) T MP 3 8 6 20 T R F GE Identification Special MEG Approved Type MP = Meter Mod™ Ring Type MPR = Meter Mod™ Ringless MPK = Meter Mod K-Base Socket Enclosures R = Type 3R rainproof Insert for Tenant Breakers Socket Rating 12 = 125A 20 = 200A 22 = 225A 40 = 400A Insert for 3-Phase Horizontal Bus Rating 8 = 800A 12 = 1200A Socket Positions 1-6 Product Number Guide for Main Modules (Product number for illustrative purposes only) T MP GE Identification 3 SB 8 R Enclosures R = Type 3R Rainproof CLL = Compression Lug Landing Kit Included ST = Shunt Trip, Factory Installed Type MP = Meter Mod III Maximum Ampere Rating 4 = 400A 6 = 600A 8 = 800A 10 = 1000A 12 = 1200A 14 = 1400A 16 = 1600A 20 = 2000A Insert for 3-Phase Type SB = Main Breaker, Top/Bottom Feed (400-1200A) SHB = Main Breaker, High Interrupting, Top/Bottom Feed (400-1200A) BB = Main Breaker, Bottom Feed (1400-2000A) BT = Main Breaker, Top Feed (1400-2000A) BU = Main Breaker with Integral Pull Box - EUSERC FT = Main Switch, Top Feed FB = Main Switch, Bottom Feed L = Main Lug U = Main Pull Box Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-7 Modular Metering Section 2 Meter Mod III How to Order Short Circuit Ratings Product Features —UL Listed (details below) —Short Circuit Ratings through 100,000 Amps RMS symmetrical —Interchangeable Single and Three-phase Main and Meter Modules —Indoor/Outdoor Construction —Individual Meter Covers —11-inch Mounting Z-Rails Included —Numerous Accessories Ordering Guidelines UL Standard Listing and File Numbers A. Determine available fault current B. Select the following: 1. Main Module (pages 2-11 through 2-18) a. Choose type (Breaker, Switch, Switch with Pull Box, Lug, or Pull Box) b. Phase c. Main Ampere Rating d. Short Circuit Rating 2. Meter Stack Modules (pages 2-19 through 2-23) 3. Tenant Breakers, Field Installed (pages 2-20 through 2-22) 4. Accessories (pages 2-19 through 2-23) Modular Metering Equipment UL Standard for Safety Meter Modules Main Modules -Breaker -Switch -Lug -Pull Box Tenant Main Breakers -THQL, TQD -THHQL, THQD -TMQL, TMQD Accessories -Meter -Other UL File No. No. 67 PanelboardsE8741 No. 489 Molded Case Circuit Breakers No. 98 Enclosed Switches No. 67 Panelboards No. 869 Service Equipment E11713 E9565 E8741 E84701 No. 489 Molded Case Circuit Breakers No. 489 Molded Case Circuit Breakers No. 489 Molded Case Circuit Breakers E11592 E11592 E11713 No. 414 Meter Sockets No. 67 Panelboards E8741 E8741 Modular Metering System Short Circuit Rating -UL Listed Available Short Circuit Current rms Symmetrical Amperes @ 240 Volts AC Switch 10,000 22,000 42,000 65,000 All All All All 100,000 All Main Module1 Breaker All All All 400-600A: TMPSHB 800-1200A: TMPSB 400-600A: TMPSHB Lug Meter Module Tenant Main Breaker Type Load Center Branch Breaker Type Panelboard Branch Breaker Type All All All All THQL, TQD, TEB, TMQL, TMQD THHQL, THQD, TMQL, TMQD TMQL, TMQD TMQD THQP, THQL THQP, THQL THQP, THQL THQP, THQL THQL, THQB THQL, THQB THQL, THQB THQL, THQB All TMQD THQP, THQL THQL, THQB 1Main Pull Box Module is UL Listed for use with and at the short circuit rating of main switch and breaker modules. Short Circuit Interrupting Ratings References: These panelboards have a maximum short circuit current rating of 100,000 RMS symmetrical amperes, 240 volts AC maximum. The actual rating depends on the branch breakers and the main breaker, if any, installed in or ahead of the panelboard. The correct combinations for various short circuit ratings follow. Any additional or replacement breakers must be a General Electric type, as indicated, with equal or greater interrupting capacity. Dimensions and Knockouts Renewal Parts Catalog Construction Details Booklet Main Circuit Breaker Maximum Short Circuit Rating, rms Symmetrical Amperes, When the breaker protecting the panelboard, 240 Vac or 120/240 Vac separate or integral, is GE Type 10,000 42,000 None, THQL, TQMV, SKH, SGD, SGH, SGL None, THHQL, THQMV, SKH, (300-1200A), SGD, SGH (125-600A) TMQB, TMQL, 300V Class T Fuse (600A max.) 65,000 SGD, SGH (125-600A) 100,000 TMQD, SGL (125-600A) 100,000 300V Class T Fuse (400A max.) 22,000 Pages 2-26 through 2-29 DET-388 DET-395 Branch Circuit Breaker And when the branch circuit breakers installed are GE Type THQP, THQL, THQLGF, TQD, THHQL, THQD, TMQD, TMQL THQP, THQL, THQLGF2, TQD, THHQL, THQD, TMQD, TMQL THQP3, THQL, THQLGF2, TQD, THHQL, THQD, TMQD, TMQL THQL, THHQL, TQD, THQD, TMQB, TMQD, TMQL THQP3, THQL, THQLGF2, TQD4, THHQL, THQD4, TMQD, TMQL THQP3, THQL, THHQL, TQD5, THQD5, TMQD, TMQL 215-30A only. 3Suitable as branch breaker when tenant main provided is: THQL, THHQL, TMQL, TQD, TMQD. 4100-200A, 2-pole only. 5125-225A, 2- and 3-pole only. 2-8 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Page Updated 04 / 2016 Modular Metering Section 2 Meter Mod III Modular Metering Series Ratings 125A Sockets Series Ratings – 400A-2000A 1PH (2P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1 Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMPSB4R TMPSHB4R TMPSB6R TMPSHB6R TMPSB8R TMPSB10R TMPSB12R TMPBB14R, TMPBT14R, TMPBB16R, TMPBB16RST, TMPBT16R, TMPBT16RST, TMPBT20R, TMPBB20R 1Does Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering SGH 400 SGL 400 SGH 600 SGL 600 SKH 800 SKH 1000 SKH 1200 1 65,000 100,000 65,000 100,000 65,000 65,000 65,000 208/120 Vac 120/240 Vac Yes RGH 1 100,000 208/120 Vac 120/240 Vac No not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead) Series Ratings – 400A-2000A 3PH (3P) Main Breakers to 2-Pole THQL/THHQL (70-125A) - 125A Sockets1 Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMP3SB4R TMP3SHB4R TMP3SB6R TMP3SHB6R TMP3SB8R TMP3SB10R TMP3SB12R TMPBB14R, TMPBT14R, TMPBB16R, TMPBB16RST, TMPBT16R, TMPBT16RST, TMPBT20R, TMPBB20R 1Does Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering SGH 400 SGL 400 SGH 600 SGL 600 SKH 800 SKH 1000 SKH 1200 3 65,000 100,000 65,000 100,000 65,000 65,000 65,000 208/120 Vac 120/240 Vac Yes RGH 3 100,000 208/120 Vac 120/240 Vac No not include 60A THQL/THHQL Tenant Breaker (Use 70A Instead) Series Ratings – 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets Meter Mod III – Main Fusible Switch Section Meter Mod III Fuse Type TMPFT4R TMPFB4R TMPFT6R TMPFB6R TMPFT8R TMPFB8R2 TMPFT12R2 TMPFB12R2 TMPFB12RT 2Field T Fuse T Fuse T Fuse T Fuse T Fuse T or L Fuse T or L Fuse T or L Fuse T Fuse Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering 1 100,000 208/120 Vac 120/240 Vac Yes3 1 100,000 208/120 Vac 120/240 Vac No convertible to Class L fusing, no kit required up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K – 100K. 3Switches Series Ratings – 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole THQL/THHQL (70-125A) - 125A Sockets Meter Mod III – Main Fusible Switch Section Meter Mod III Fuse Type TMP3FT4R TMP3FB4R TMP3FT6R TMP3FB6R TMP3FT8R2 TMP3FB8R TMP3FT12R2 TMP3FB12R TMP3FB12RT TMP3FB12RST TMP3FT16R, TMP3FB16R, TMP3FB16RST, TMP3FT20R, TMP3FB20R, TMP3FB20RST 2Field T Fuse T Fuse T Fuse T Fuse T Fuse T or L Fuse T or L Fuse T or L Fuse T Fuse T or L Fuse L Fuse Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering 3 100,000 208/120 Vac 120/240 Vac Yes3 3 100,000 208/120 Vac 120/240 Vac No 3 100,000 208/120 Vac 120/240 Vac No convertible to Class L fusing, no kit required up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K – 100K. 3Switches Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-9 Page Updated 04 / 2016 Modular Metering Section 2 Meter Mod III Modular Metering Series Ratings 200A Sockets Series Ratings – 400A-2000A 1PH (2P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMPSB4R TMPSHB4R TMPSB6R TMPSHB6R TMPSB8R TMPSB10R TMPSB12R TMPBB14R, TMPBT14R, TMPBB16R, TMPBB16RST, TMPBT16R, TMPBT16RST, TMPBT20R, TMPBB20R Main Phase Series Rating of Main (AIC) SGH 400 SGL 400 SGH 600 SGL 600 SKH 800 SKH 1000 SKH 1200 1 65,000 100,000 65,000 100,000 65,000 65,000 65,000 RGH 1 100,000 Voltage of Main Voltage of Tenant Approved For Modular Metering 208/120 Vac 120/240 Vac Yes No Yes No No No No 208/120 Vac 120/240 Vac No Voltage of Tenant Approved For Modular Metering Series Ratings – 400A-2000A 3PH (3P) Main Breakers to 2-Pole TQD (100-200A) - 200A Sockets Meter Mod III Main Breaker Section Meter Mod III Breaker Frame TMP3SB4R TMP3SHB4R TMP3SB6R TMP3SHB6R TMP3SB8R TMP3SB10R TMP3SB12R TMPBB14R, TMPBT14R, TMPBB16R, TMPBB16RST, TMPBT16R, TMPBT16RST, TMPBT20R, TMPBB20R Main Phase Series Rating of Main (AIC) Voltage of Main SGH 400 SGL 400 SGH 600 SGL 600 SKH 800 SKH 1000 SKH 1200 3 65,000 100,000 65,000 100,000 65,000 65,000 65,000 208/120 Vac 120/240 Vac Yes No Yes No No No No RGH 3 100,000 208/120 Vac 120/240 Vac No Series Ratings – 400A-2000A 1PH (2P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets Meter Mod III – Main Fusible Switch Section Meter Mod III Fuse Type TMPFT4R TMPFB4R TMPFT6R TMPFB6R TMPFT8R TMPFB8R TMPFT12R TMPFB12R TMPFB12RT 1Switches T Fuse T Fuse T Fuse T Fuse T Fuse T or L Fuse L Fuse L Fuse T Fuse Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering 1 100,000 208/120 Vac 120/240 Vac Yes1 1 100,000 208/120 Vac 120/240 Vac No up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K – 100K. Series Ratings – 400A-2000A 3PH (3P) Main Fusible Switches to 2-Pole TQD (100-200A) - 200A Sockets Meter Mod III – Main Fusible Switch Section Meter Mod III Fuse Type TMP3FT4R TMP3FB4R TMP3FT6R TMP3FB6R TMP3FT8R TMP3FB8R TMP3FT12R TMP3FB12R TMP3FB12RT TMP3FB12RST TMP3FT16R, TMP3FB16R, TMP3FB16RST, TMP3FT20R, TMP3FB20R, TMP3FB20RST 1Switches 2-10 T Fuse T Fuse T Fuse T Fuse T Fuse T or L Fuse L Fuse L Fuse T Fuse T or L Fuse L Fuse Main Phase Series Rating of Main (AIC) Voltage of Main Voltage of Tenant Approved For Modular Metering 3 100,000 208/120 Vac 120/240 Vac Yes1 3 100,000 208/120 Vac 120/240 Vac No 3 100,000 208/120 Vac 120/240 Vac No up to 600A rated for series rating at 42K and below; switches up to 400A rated for series rating from >42K – 100K. BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Main Breaker Modules Single-Phase and Three-Phase —Single-Phase Mains have a neutral, A-Phase, B-Phase, and Ground, and may be connected to Three-Phase horizontal bus stacks. However, output is only single-phase. —All Mains are required to be center feed only when the main circuit breaker rating is larger than the horizontal bus amperage rating. TMPSB4R Main Breaker Single-Phase, Three-Wire 120/240 Vac Breaker included, top or bottom feed. 80% Rated MCB. Main Ampere Rating 400 400 600 600 800 1000 1200 1400 1400 1600 1600 1600 1600 2000 2000 IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral 65 kAIC 100 kAIC 65 kAIC 100 kAIC 65 kAIC 65 kAIC 65 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al/Cu (3) 3/0 -5001 Al(4) 250-500 CU(4) 250/3501 Al(4) 250-500 CU(4) 250/3501 (4) 500-1000 kcmil (4) 500-1000 kcmil Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 kcmil Al/Cu (4) 500-1000 kcmil (6) #2 – 600 kcmil (6) #2 – 600 kcmil (2) 2 -600 (2) 2 -600 (2) 2 -600 (2) 2 -600 (4) 250-5002 (4) 250-5002 (4) 250-5002 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 (6) #2 – 600 kcmil (6) #2 – 600 kcmil Product Number TMPSB4R TMPSHB4R TMPSB6R TMPSHB6R TMPSB8R TMPSB10R TMPSB12R7 TMPBB14R4,6 TMPBT14R5,6 TMPBB16R4,6 TMPBB16RST3,4,6 TMPBT16R5,6 TMPBT16RST3,5,6 TMPBT20R5,6 TMPBB20R4,6 Main Breaker Single-Phase, Three-Wire 120/240 Vac with Arc Reduction Means The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87 Main Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral 400 to less than 1200 – Top or Bottom – – 1200 – Top or Bottom – – 1400 100 kAIC (4) 250-500 100 kAIC (4) 500-1000 (4) 500-1000 2000 100 kAIC Bottom Bottom Top Bottom (4) 500-1000 1600 (6) #2-600 (6) #2-600 Product Number Use Standard Part #. Code effects only 1200A and greater Use 1400 or 1600A and advise GE sales rep to make trip unit 1200A TMPBB14RAR TMPBB16RAR TMPBT16RAR TMPBB20RAR NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If you need a trip setting that is different than the frame (For example, if you need a TMPBB16RAR 1600A frame with a 1200A trip), please inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory. 1Optional lug TCAL124 field installed wire range (3) 300-750 kcmil. 2Optional neutral lug field installed wire range (3) 1/0-750 kcmil. Lug kit part number TMPL750. 3Includes 110-240 Vac shunt trip. 4Bottom feed. 5Top feed. 6Fixed Rating Plug not Field adjustable. 7To meet NEC 2014 Arc Energy Reduction (Section 240.87), please use a 1175A rating plug. Product Number SRPK1200A1175, order separately. Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-11 Modular Metering Section 2 Meter Mod III Main Breaker Modules Single-Phase and Three-Phase Main Breaker Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac Breaker included, top or bottom feed. 80% Rated MCB Main Ampere Rating 400 400 600 600 800 1000 1200 1400 1400 1600 1600 1600 1600 1600 2000 2000 2000 2000 2000 IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral 65 kAIC 100 kAIC 65 kAIC 100 kAIC 65 kAIC 65 kAIC 65 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al :(2) 2/0 - 500 or (1) 6 -600 Cu 2/0 - 400 or (1) 6 -600 Al/Cu (3) 3/0 -5001 Al(4) 250-500 Cu(4) 250/3501 Al(4) 250-500 Cu(4) 250/3501 (4) 500-1000 kmcil (4) 500-1000 kmcil Al/Cu (4) 500-1000 Compression Lugs Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 (6) #2-600 kcmil (6) #2-600 kcmil Compression Lugs (6) #2-600 kcmil (6) #2-600 kcmil (2) 2 -600 (2) 2 -600 (2) 2 -600 (2) 2 -600 (4) 250-5002 (4) 250-5002 (4) 250-5002 (4) 500-1000 kmcil (4) 500-1000 kmcil Al/Cu (4) 500-1000 Compression Lugs Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 (6) #2-600 kcmil (6) #2-600 kcmil Compression Lugs (6) #2-600 kcmil (6) #2-600 kcmil Product Number TMP3SB4R TMP3SHB4R TMP3SB6R TMP3SHB6R TMP3SB8R TMP3SB10R TMP3SB12R9 TMP3BB14R4,7 TMP3BT14R5,7 TMP3BB16R4,7 TMP3BB16RCLL4,7 TMP3BB16RST3,4,7 TMP3BT16R5,7 TMP3BT16RST3.5.7 TMP3BT20R5,7 TMP3BB20R4,7 TMP3BB20RCLL4,7 TMP3BT20RST3,5,7 TMP3BB20RST3,4,7 Main Breaker Three-Phase, Four-Wire 208Y/120 Vac or Three-Phase, Four-Wire 120/240 Vac, Delta Hi-Leg with Arc Reduction Means The main breaker in this section has an arc reduction means that satisfies the requirement of NEC 2014 Section 240.87 Main Ampere Rating IC Rating (Max) Feed Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral 400 to less than 1200 – Top or Bottom – – 1200 – Top or Bottom – – 1400 100 kAIC (4) 500-1000 (4) 500-1000 1600 100 kAIC (4) 500-1000 (4) 500-1000 2000 100 kAIC Bottom Top Bottom Top Top Bottom (6) #2-600 (6) #2-600 Product Number Use Standard Part #. Code effects only 1200A and greater Use 1400 or 1600A and advise GE sales rep to make trip unit 1200A TMP3BB14RAR TMP3BT14RAR TMP3BB16RAR TMP3BT16RAR TMP3BT20RAR TMP3BB20RAR NOTE: These main sections use type RG Breakers. These breakers no longer have rating plugs; they have factory installed trip units. If you need a trip setting that is different than the frame (For example, if you need a TMP3BB16RAR 1600A frame with a 1200A trip), please inform your GE sales rep at time of order entry. A request will be made to have this manually changed at the factory. Shunt-Trip - Field Installed For Use on all Main Breaker Modules Main Breaker Modules Alternate Rating Plugs – Field Installed8 Main Ampere Rating 4006 4006 4006 4006 600 600 600 800 800 1000 1200 Alternate Rating Product Number 225 250 300 350 400 450 500 600 700 800 1000 SRPG400A225 SRPG400A250 SRPG400A300 SRPG400A350 SRPG600A400 SRPG600A450 SRPG600A500 SRPK800A600 SRPK800A700 SRPK1200A800 SRPK1200A1000 Shunt Trip 120 Vac 240 Vac Product Number SAST1 SAST2 1Optional lug TCAL124 field installed wire range (3) 300-750 kcmil. 2Optional neutral lug field installed wire range (3) 1/0-750 kcmil. Lug kit part number TMPL750. 3Includes 110-240 Vac shunt trip. 4Bottom feed. 5Top feed. 6Alternate for 400A frame. 7Fixed Rating Plug not Field adjustable. 8 Not available for 1400, 1600, and 2000A Mains 9 To meet NEC 2014 Arc Energy Reduction (Section 240.87), please use a 1175A rating plug. Product Number SRPK1200A1175, order separately. 2-12 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Main Breaker Modules Single-Phase and Three-Phase Factory Installed Lug Kit Phase Neutral Main Breaker Amp Rating Wire Size Wire Size TMPSB4R TMP3SB4R TMPSHB4R TMP3SHB4R TMPSB6R TMP3SB6R TMPSHB6R TMP3SHB6R TMPSB8R TMP3SB8R TMPSB10R TMP3SB10R TMPSB12R TMP3SB12R TMPBB14R TMPBT14R TMP3BB14R TMP3BT14R TMPBB16R TMP3BB16R TMPBB16RST TMP3BB16RST TMPBT16R TMP3BT16R TMPBT16RST TMP3BT16RST TMPBB20R TMP3BB20R TMPBT20R TMP3BT20R 400 400 400 400 600 600 600 600 800 800 1000 1000 1200 1200 1400 1400 1400 1400 1600 1600 1600 1600 1600 1600 1600 1600 2000 2000 2000 2000 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL:(2) 2/0-500 or (1) 6-600 Cu 2/0-400 or (1) 6-600 AL/Cu (3) 3/0-500 AL/Cu (3) 3/0-500 Al(4) 250-500 Cu(4) 250/350 Al(4) 250-500 Cu(4) 250/350 Al(4) 250-500 Cu(4) 250/350 Al(4) 250-500 Cu(4) 250/350 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 Al/Cu (6) #2-600 Al/Cu (6) #2-600 (2) 2-600 (2) 2-600 (2) 2-600 (2) 2-600 (2) 2-600 (2) 2-600 (2) 2-600 (2) 2-600 (4) 250-500 (4) 250-500 (4) 250-500 (4) 250-500 (4) 250-500 (4) 250-500 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (4) 500-1000 Al/Cu (6) #2-600 Al/Cu (6) #2-600 Al/Cu (6) #2-600 Al/Cu (6) #2-600 GE Lug Kit Product No. TCLK265 TCLK365 TCLK265 TCLK365 TCLK265 TCLK365 TCLK265 TCLK365 TCAL124 TCAL124 TCAL125 TCAL125 TCAL125 TCAL125 TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL1600RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD Total Lugs Per Device Lugs Per Kit 2 lugs per kit 3 lugs per kit 2 lugs per kit 3 lugs per kit 2 lugs per kit 3 lugs per kit 2 lugs per kit 3 lugs per kit 1 lug per kit 1 lug per kit 1 lug per kit 1 lug per kit 1 lug per kit 1 lug per kit 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug 9 lugs per kit 9 lugs per kit 9 lugs per kit 9 lugs per kit 3 lugs per device 3 lugs per device 4 lugs per device 4 lugs per device 3 lugs per device 4 lugs per device 3 lugs per device 4 lugs per device 3 lugs per device 4 lugs per device 3 lugs per device 4 lugs per device 6 lugs per device, 3 lugs/neutral 9 lugs per device, 3 lugs/neutral 6 lugs per device, 3 lugs/neutral 9 lugs per device, 3 lugs/neutral Optional Lug Kit Main Breaker TMPBB14R TMPBT14R TMP3BB14R TMP3BT14R TMPBB16R TMP3BB16R TMPBB16RST TMP3BB16RST TMPBT16R TMP3BT16R TMPBT16RST TMP3BT16RST Rev. 11/13 Data subject to change without notice Amp Rating 1400 1400 1400 1400 1600 1600 1600 1600 1600 1600 1600 1600 Wire Size (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 www.geindustrial.com Phase GE Lug Kit Product No. TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD TMPL2000RD Neutral GE Lug Product No. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Lugs Per Kit 9 9 9 9 9 9 9 9 9 9 9 9 Wire Size (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 (6) #2-600 BuyLog™ Catalog GE Lug Kit Product No. TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N TMBP2000N 2-13 Modular Metering Section 2 Meter Mod III Main Fusible Modules Single-Phase and Three-Phase —Single-Phase Mains have a neutral, A-Phase, B-Phase, and Ground, and may be connected to Three-Phase horizontal bus stacks. However, output is only single-phase. —All Mains are required to be center feed only when the main fusible switch rating is larger than the horizontal bus amperage rating. TMPFB6R Main Fusible Switch Single-Phase, Three-Wire 120/240 Vac T-Fuses not included (available from table on page 2-18). Wire Entry Top Top Top Top Bottom Bottom Bottom Bottom Bottom Main Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral Stud sets per Phase and Neutral Compression Lug Landing Kit2 400 600 800 1200 400 600 800 1200 1200 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-500 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-600 (4) 2-500 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-500 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-600 (4) 2-500 1 1 1 Order Separately Order Separately Order Separately 1 1 1 Order Separately Order Separately Order Separately Product Number TMPFT4R1 TMPFT6R1 TMPFT8R1 TMPFT12R2 TMPFB4R1 TMPFB6R1 TMPFB8R1 TMPFB12RT3 TMPFB12R4 Main Fusible Switch Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac T-Fuses not included (available from table on page 2-18). Wire Entry Top Top Top Top Top Top Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Main Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral Stud sets per Phase and Neutral Compression Lug Landing Kit2 400 600 800 1200 1600 2000 400 600 800 1200 1200 1600 2000 1200 1600 2000 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 4-600 (6) 4-600 (8) 4-600 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-600 (4) 4-600 (6) 4-600 (8) 4-600 (4) 4-600 (6) 4-600 (8) 4-600 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 4-600 (6) 4-600 (8) 4-600 (1) 1/0-750 or (2) 1/0 -300 (2) 2- 600 (4) 3/0-750 (4) 2-600 (4) 4-600 (6) 4-600 (8) 4-600 (4) 4-600 (6) 4-600 (8) 4-600 1 1 1 Order Separately Order Separately Order Separately 1 1 1 Order Separately Order Separately Order Separately Product Number TMP3FT4R1 TMP3FT6R1 TMP3FT8R1 TMP3FT12R2 TMP3FT16R2 TMP3FT20R2 TMP3FB4R1 TMP3FB6R1 TMP3FB8R1 TMP3FB12RT5 TMP3FB12R6 TMP3FB16R2 TMP3FB20R2 TMP3FB12RST2,7 TMP3FB16RST2,7 TMP3FB20RST2,7 1Class T fuse only. 2Class L fuse only. Bolted pressure switch. 3TMPFB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMPFB12R, but is significantly less expensive. 4TMPFB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMPFB12RT, but more expensive. 5TMP3FB12RT is a standard fusible switch that uses only Class T fuses. This unit is less robust and smaller than the TMP3FB12R, but is significantly less expensive. 6TMP3FB12R is a bolted pressure switch that uses only Class L fuses. This unit is larger and more robust than the TMP3FB12RT, but more expensive. 7Product numbers ending in “ST” have shunt tripping style bolted pressure switch. 2-14 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Main Fusible Modules Single-Phase and Three-Phase Factory Installed Lug Kit Main Switch TMPFT4R TMP3FT4R TMPFT6R TMP3FT6R TMPFT8R TMP3FT8R TMPFT12R TMP3FT12R TMPFB4R TMP3FB4R TMPFB6R TMP3FB6R TMP3FB8R TMP3FB8R TMPFB12R TMP3FB12R TMPFB12RT TMP3FB12RT TMP3FT16R TMP3FB16R TMP3FT20R TMP3FB20R TMPFB4RCLL TMP3FB4RCLL TMPFB6RCLL TMP3FB6RCLL TMPFB8RCLL TMP3FB8RCLL TMPFB12RCLLT TMP3FB12RCLLT Main Switch TMPFT4R TMP3FT4R TMPFT6R TMP3FT6R TMPFT8R TMP3FT8R TMPFB4R TMP3FB4R TMPFB6R TMP3FB6R TMP3FB8R TMP3FB8R Rev. 11/13 Data subject to change without notice Amp Rating Phase Wire Size 400 400 600 600 800 800 1200 1200 400 400 600 600 800 800 1200 1200 1200 1200 1600 1600 2000 2000 400 400 600 600 800 800 1200 1200 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300 (2) 2-600 (2) 2-600 (4) 3/0-750 (4) 3/0-750 (4) 2-500 (4) 2-600, 2 lugs per phase (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300 (2) 2-600 (2) 2-600 (4) 3/0-750 (4) 3/0-750 (4) 2-500 (8) 2-600, (4 lugs, 2-holes per lug) (4) 2-600, 2 lugs per phase (4) 2-600, 2 lugs per phase (5) 4-600 (8) 2-600 (6) 4-600 (8) 2-600 Accepts compression lugs, 1 landings per phase Accepts compression lugs, 1 landings per phase Accepts compression lugs, 2 landings per phase Accepts compression lugs, 2 landings per phase Accepts compression lugs, 2 landings per phase Accepts compression lugs, 2 landings per phase Accepts compression lugs, 3 landings per phase Accepts compression lugs, 3 landings per phase Amp Rating 400 400 600 600 800 800 400 400 600 600 800 800 Neutral Wire Size Optional Lug Kit: Phase Wire GE Lug Kit Size Product No. (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug Not available Not available (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug (4) 3/0-750, 4 cables per lug Not available Not available www.geindustrial.com TMPL40 TMPL40 TMPL40 TMPL40 Not available Not available TMPL40 TMPL40 TMPL40 TMPL40 Not available Not available (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300 (2) 2-600 (2) 2-600 (4) 3/0-750 (4) 3/0-750 (4) 2-500 (4) 2-600 (1) 1/0-750 or (2) 1/0-300 (1) 1/0-750 or (2) 1/0-300 (2) 2-600 (2) 2-600 (4) 3/0-750 (4) 3/0-750 (4) 2-500 GE Lug Kit Product No. Lugs Per Kit TMPL40 TMPL40 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug TMPL40 TMPL40 1 lug per kit, 4 holes per lug 1 lug per kit, 4 holes per lug (4) 2-600 (4) 2-600 (5) 4-600 (8) 2-600 (6) 4-600 (8) 2-600 Optional Lug Kit: Compression Wire GE Lug Kit Size Product No. Compression Compression Compression Compression Compression Compression Compression Compression Compression Compression Compression Compression BuyLog™ Catalog TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 TMP3F8CLL1 2-15 Modular Metering Section 2 Meter Mod III Main Fusible w/Pull Box and Main Lug Modules Single-Phase and Three-Phase TMP3L6R Main Fusible Switch w/Integral Pull Box Single-Phase, Three-Wire 120/240 Vac End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of switch order TMPS12 spacer. All modules accept Class T fuse. Main Wire Entry Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral Compression Lug Landing Kit Product Number Bottom 400 100 kAIC TMPFB4RCLL 600 100 kAIC Included TMPFB6RCLL Bottom 800 100 kAIC Included TMPFB8RCLL Bottom 12001 100 kAIC Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Included Bottom Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Included TMPFB12RCLLT 1Center-feed only for single-phase meter modules with 800A horizontal bus rating. Main Fusible Switch w/Integral Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac End or center mounting. Lugs not included. Meets EUSERC requirements. When meter stacks are to be mounted on handle side of switch, order TMPS12 spacer. All modules accept Class T fuse. Main Wire Entry Ampere Rating IC Rating (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral Compression Lug Landing Kit Product Number Bottom 400 100 kAIC TMP3FB4RCLL 600 100 kAIC Included TMP3FB6RCLL Bottom 800 100 kAIC Included TMP3FB8RCLL Bottom 1200 100 kAIC Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Included Bottom Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Compression Lug Landing Kit Included (NEMA 2-Hole Spacing) Included TMP3FB12RCLLT Main Lug Single-Phase, Three-Wire 120/240 Vac End or center mounting. Lugs included. Wire Entry Bottom / Top Bottom / Top Bottom/Top Bottom/Top Bottom/Top Main Ampere Rating 400 600 800 1200 1600 IC Rating2 (Max) 100 kAIC 100 kAIC 100 kAIC Main Wire Size AWG/kcmil Cu/Al - Phase (2) 1/0-750 or (4) 1/0 -300 (3) 1/0-750 or (6) 1/0-300 (6) 250-500 Main Wire Size Stud sets per Phase AWG/kcmil Cu/Al - Neutral and Neutral (2) 1/0-750 or (4) 1/0 -300 (3) 1/0-750 or (6) 1/0 -300 (6) 250-500 2 3 3 Compression Lug Landing Kit Product Number Order Separately Order Separately Order Separately Use 3-Phase Use 3-Phase TMPL8R TMPL12R TMPL16R Compression Lug Landing Kit Product Number Order Separately Order Separately Order Separately Order Separately Order Separately Order Separately Order Separately Order Separately TMP3L4R TMP3L4RCU3 TMP3L6R TMP3L6RCU3 TMP3L8R TMP3L8RCU3 TMP3L12R TMP3L16R 2Limited to the lowest marked short circuit rating of the main and meter modules used. Main Lug Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac End or center mounting. Lugs included. Wire Entry Main Ampere Rating IC Rating2 (Max) Main Wire Size AWG/kcmil Cu/Al - Phase Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top 400 400 600 600 800 800 1200 1600 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC 100 kAIC (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 (2) 250-500 (2) 250-500 (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0-300 (3) 1/0-750 or (6) 1/0-300 (6) 250-500 Main Wire Size Stud sets per Phase AWG/kcmil Cu/Al - Neutral and Neutral (1) 6-600 or (2) 1/0-250 (1) 6-600 or (2) 1/0-250 (2) 250-500 (2) 250-500 (2) 1/0-750 or (4) 1/0 -300 (2) 1/0-750 or (4) 1/0 -300 (3) 1/0-750 or (6) 1/0 -300 (6) 250-500 1 1 1 1 2 2 2 2 2Limited to the lowest marked short circuit rating of the main and meter modules used. 3Copper bus. 2-16 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Main Lug Modules Single-Phase and Three-Phase Factory Installed Lug Kit Main Lug (Terminal Box) Amp Rating Phase Wire Size TMP3L4R TMP3L6R TMPL8R TMP3L8R TMPL12R TMP3L12R TMPL16R TMP3L16R 400 600 800 800 1200 1200 1600 1600 (1) 2/0-600 or (2) #6-250 (2) 250-500 per lug (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0-300 (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0-300 (6) 250-500 (6) 250-500 Main Lug (Terminal Box) Amp Rating Wire Size TMP3L4R 400 (2) 250-500 per lug TMP3L6R 600 Not available TMPL8R 800 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L8R 800 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMPL12R 1200 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression TMP3L12R 1200 (2) 250-500 TMPAL30 1 lug per kit, 1 lug per phase Compression (4) 1/0-750 or (8) 1/0-300 (4) 1/0-750 or (8) 1/0-300 TMP3L16BLK 1 kit per device, 4 connector assy's w/4 lugs each (16 total lugs), 1 assy/phase 1 kit per device, 4 connector assy's w/4 lugs each (16 total lugs), 1 assy/phase TMPL16R TMP3L16R 1600 1600 Rev. 11/13 Data subject to change without notice Neutral Wire Size (1) 2/0-600 or (2) #6-250 (2) 250-500 per lug (2) 1/0-750 or (4) 1/0-300 (2) 1/0-750 or (4) 1/0-300 (3) 1/0-750 or (6) 1/0-300 (3) 1/0-750 or (6) 1/0-300 (6) 250-500 (6) 250-500 GE Lug Kit Product No. TMMLK1(w/ instr) TMPAL30 TMPL750 TMPL750 TMPL750 TMPL750 TMPAL30 TMPAL30 Optional Lug Kit: Phase GE Lug Kit Product No. Lugs Per Kit TMPAL30 Lugs Per Kit 1 lug per kit, 1 lug per phase Wire Size Compression Compression TMP3L16BLK www.geindustrial.com 1 lug/kit, 1 lug per phase, 2 hole lug 1 lug per kit, 1 lug per phase 2 lugs per phase, 3 lugs per kit 2 lugs per phase, 3 lugs per kit 3 lugs per phase, 3 lugs per kit 3 lugs per phase, 3 lugs per kit 1 lug per kit, 3 lugs per phase 1 lug per kit, 3 lugs per phase Total Lugs Per Device 9 lugs total 12 lugs total Optional Lug Kit: Compression GE Lug Kit Product No. Lugs Per Kit 2 studs per phase, double stack TMP3L6CLL for up to 2 conductors per phase 2 studs per phase, double stack TMP3L6CLL for up to 2 conductors per phase 4 studs per phase, double stack TMP3L12CLL1 for up to 4 conductors per phase 4 studs per phase, double stack TMP3L12CLL1 for up to 4 conductors per phase 4 studs per phase, double stack TMP3L12CLL1 for up to 4 conductors per phase 4 studs per phase, double stack TMP3L12CLL1 for up to 4 conductors per phase Compression TMP3L16CLL1 Compression TMP3L16CLL1 BuyLog™ Catalog 2-17 Modular Metering Section 2 Meter Mod III Main Pull Box Modules and Accessories Single-Phase and Three-Phase TMPU4R Main Pull Box Single-Phase, Three-Wire 120/240 Vac End mounting. Lugs only included; cross bus not included. Wire Entry Main Ampere Rating IC Rating1 (Max) Bottom/Top 400 100 kAIC Bottom/Top 800 100 kAIC Bottom/Top 1200 100 kAIC Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - Neutral Stud sets per Phase and Neutral Compression Lug Landing Kit Product Number (1) 1/0-750 or (2) 1/0 -300 (Load) (2) 1/0-750 or (4) 1/0 -300 (Load) (4) 2-600 (Load) (1) 1/0-750 or (2) 1/0 -300 (Load) (2) 1/0-750 or (4) 1/0 -300 (Load) (4) 2-600 (Load) 1 Included TMPU4R 2 Included TMPU8R 3 Included TMPU12R 1Limited to the lowest marked short circuit rating of the main and meter modules used. Main Pull Box Three-Phase, Four-Wire / Single-Phase, Three-Wire 120/240 Vac, 208Y/120 Vac, 240/120 Vac End or center mounting. Lugs only included; cross bus not included. Wire Entry Main Ampere Rating IC Rating1 (Max) Bottom/Top 400 100 kAIC Bottom/Top 800 100 kAIC Bottom/Top 1200 100 kAIC Main Wire Size AWG/kcmil Cu/Al - Phase Main Wire Size AWG/kcmil Cu/Al - NeutraL Stud sets per Phase and Neutral Compression Lug Landing Kit Product Number (1) 1/0-750 or (2) 1/0-300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (4) 2-600 (Load) (1) 1/0-750 or (2) 1/0 -300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (4) 2-600 (Load) 1 Included TMP3U4R 2 Included TMP3U8R 3 Included TMP3U12R 1Limited to the lowest marked short circuit rating of the main and meter modules used. Factory Installed Lug Kit Class T Fuses Frame Size 400 400 400 400 600 600 800 1200 Ampere Rating Product Number 250 300 350 400 500 600 800 1200 TFUSE250 TFUSE300 TFUSE350 TFUSE400 TFUSE500 TFUSE600 TFUSE800 A3T1200 Phase Main Pull Box Amp Rating TMPU4R 400 TMP3U4R 400 TMPU8R 800 TMP3U8R 800 TMPU12R TMP3U12R 1200 1200 Description Neutral Wire Size (1) 1/0-750 or (2) 1/0-300 (Load) (1) 1/0-750 or (2) 1/0-300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (4) 2-600 (load) (4) 2-600 (load) (1) 1/0-750 or (2) 1/0-300 (Load) (1) 1/0-750 or (2) 1/0-300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (2) 1/0-750 or (4) 1/0-300 (Load) (4) 2-600 (load) (4) 2-600 (load) GE Lug Kit Product No. TMPL750 TMPL750 TMPL750 TMPL750 Lugs Per Kit 1 lug per phase, 3 lugs per kit 1 lug per phase, 3 lugs per kit 2 lugs per phase, 3 lugs per kit 2 lugs per phase, 3 lugs per kit Lug and Neutral Kits Product Number Description Accepts (4) 3/0-750 mcm for use with 400 and 600 amp switch (2) 250-500 mcm for use with 800 and 1200 amp main lug Neutral Kit, for 1600A and 2000A Main Breaker Lug Kit, for 1200A Main Lug device (3) 1/0-750 or (6) 1/0-300 Lug Kit, for 1600A main lug device, (8) 1/0-300 or (4)2-750 mcm Crimp Lug Pad Kit(4) 1600A Main Lug Alternate Lug Kit for 1400A and 1600A Main Breaker TMPL40 TMPAL30 TMBP2000N TMP3L12BLK TMP3L16BLK TMP3L16CLL3 TMPL2000RD 3Single lug but can put up to 2 lugs per phase on main. 2-18 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Page Updated 04 / 2016 Modular Metering Section 2 Meter Mod III Meter Stack Modules Single-Phase Plus Accessories TMP8512R TMPR8220R Product Features —UL listed —800 amp, 4-wire cross bus (aluminum), except where noted below. —Ring-type and Ringless Sockets —Front Accessible Field Phase Balancing by Meter Module —(1) 14-4 Equipment Ground per Socket, Factory Installed Product Features —UL listed —1200 amp, 4-wire cross bus (aluminum) —Ring-type and Ringless Sockets —Front Accessible Field Phase Balancing by Meter Module —(1) 14-4 Equipment Ground per Socket, Factory Installed Ring Type Socket - 800A Horizontal Bussing Ring-Type Socket - 1200A Horizontal Bussing Socket Amps 125A 125A 125A 125A 125A 200A 200A 200A 200A 200A No. of Sockets 2 3 4 5 6 2 3 4 5 5 Standard Product Number TMP8212R TMP8312R TMP8412R TMP8512R TMP8612R TMP8220R TMP8320R TMP8420R TMP8520R TMP8520RBUS3 MEG Product Number2 TMP8212RF TMP8312RF TMP8412RF TMP8512RF TMP8612RF Use TMP8320RF TMP8320RF TMP8420RF Use two smaller sections Use two smaller sections Socket Amps 125A 125A 125A 125A 125A 200A 200A 200A 200A 200A No. of Sockets 2 3 4 5 6 2 3 4 5 5 Standard Product Number TMP12212R TMP12312R TMP12412R TMP12512R TMP12612R TMP12220R TMP12320R TMP12420R TMP12520R TMP12520RBUS3 MEG Product Number2 TMP12212RF TMP12312RF TMP12412RF TMP12512RF TMP12612RF TMP12220RF TMP12320RF TMP12420RF TMP12520RF Use TMP12520RF One snap-type, aluminum sealing ring (TSR5) per socket included. Ringless Type Socket - 800A Horizontal Bussing (Includes 5th Jaw Standard) Standard Socket No. of Product Amps Sockets Number 125A 2 TMPR8212R 125A 3 TMPR8312R 125A 4 TMPR8412R MEG Product Number2 TMPR8212RF TMPR8312RF TMPR8412RF 125A 5 TMPR8512R TMPR8512RF 125A 6 TMPR8612R TMPR8612RF 200A 2 TMPR8220R Use TMPR8320RF 200A 3 TMPR8320R TMPR8320RF 200A 4 TMPR8420R TMPR8420RF 200A 5 TMPR8520R TMPR8520RF 200A 5 TMPR8520RBUS3 Use TMPR8520RF MEG & Horned Bypass Product Number2 TMPR8212RHBF1 TMPR8312RHBF1 TMPR8412RHBF1 Use TMPR8512RF+ TMPR8512RHB TMBPH20A Use TMPR8612RF+ TMPR8612RHB TMBPH20A Use TMPR8220RHB+ TMPR8220RHB TMBPH20A Use TMPR8320RHB+ TMPR8320RHB TMBPH20A TMPR8420RHB TMPR8420RHBF1 Use TMPR8520RHB+ TMPR8520RHB TMBPH20A Use TMPR8520RF+ TMPR8520RHBBUS3 TMBPH20A Horned Bypass Product Number1 TMPR8212RHB TMPR8312RHB TMPR8412RHB 1Includes horn by-pass. 2”F” units have an additional cotter pin that has been added to the meter socket assembly that will keep the meter socket from detaching from the base. This change meets the new MEG requirements. 3Parts with “BUS” on the end have the horizontal bussing centerline on the 3rd meter rather than 2nd meter, making the unit shorter from the centerline for applications where height of top meter may be an issue. Ringless Type Socket - 1200A Horizontal Bussing (Includes 5th Jaw Standard) Socket No. of Amps Sockets 125A 2 125A 3 125A 125A 4 5 125A 6 200A 2 200A 3 200A 4 200A 5 200A 5 Data subject to change without notice www.geindustrial.com MEG Product Number2 MEG & Horned Bypass Product Number2 TMPR12412RF+ TMPR12412RF+ TMPR12212R TMPR12212RHB (2) TMCB12B+ (2) TMCB12B (1) TMPBH20A TMPR12412RF+ TMPR12412RF+ TMPR12312R TMPR12312RHB (1) TMCB12B+ (1) TMCB12B (1) TMPBH20A TMPR12412R TMPR12412RF TMPR12412RHB TMPR12412RHBF1 TMPR12512R TMPR12512RF TMPR12512RHB TMPR12512RHBF1 TMPR12612RF+ TMPR12612R TMPR12612RF TMPR12612RHB TMBPH20A TMPR12420RF+ TMPR12420RF+ TMPR12220R TMPR12220RHB (2) TMCB20B+ (2) TMCB20B (1) TMPBH20A TMPR12420RF+ TMPR12420RF+ TMPR12320R TMPR12320RHB (1) TMCB20B+ (1) TMCB20B (1) TMPBH20A TMPR12420R TMPR12420RF TMPR12420RHB TMPR12420RHBF1 TMPR12520RF+ TMPR12520R TMPR12520RF TMPR12520RHB TMBPH20A Use TMPR12520RF+ TMPR12520RBUS3 Use TMPR12520RF TMPR12520RHBBUS3 TMBPH20A Horned Bypass Product Number1 Ring Type Socket Factory Phase Balanced (w/Copper Bus) Socket Amps 125A 125A 125A 125A 125A 125A 125A 125A 125A Rev. 11/13 Standard Product Number No. of Sockets 2 2 2 3 3 3 4 4 4 BuyLog™ Catalog Product Number TMP8212RAB TMP8212RAC TMP8212RBC TMP8312RAB TMP8312RAC TMP8312RBC TMP8412RAB TMP8412RAC TMP8412RBC 2-19 Modular Metering Section 2 Meter Mod III Meter Stack Modules Single-Phase Plus Accessories Tenant Main Circuit Breakers 10,000 AIC Socket Amps 125 125 125 125 125 125 125 125 200 200 200 200 200 200 Ampere Rating 60 70 80 90 100 110 125 125 100 125 150 175 200 225 Wire Size Load Lugs (1) #8-#3 CU; #8-#3 AL (1) #6-1/0 CU; #4-#1/0 AL (1) #6-1/0 CU; #4-#1/0 AL (1) #6-1/0 CU; #4-#1/0 AL (1) #6-1/0 CU; #4-#1/0 AL (1) #6-1/0 CU; #4-#1/0 AL (1) #2-2/0 CU; #2-2/0 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL Product Number THQL2160 THQL2170 THQL2180 THQL2190 THQL21100 THQL21110 THQL21125 TMQL21125SF1 TQD22100 TQD22125 TQD22150 TQD22175 TQD22200 Use TMQD Tenant Main Circuit Breakers 22,000 AIC Socket Amps 125 125 125 125 125 125 125 200 200 200 200 200 200 Ampere Rating 60 70 80 90 100 110 125 100 125 150 175 200 225 Wire Size Load Lugs (1) #8-3 CU; #8-2 AL (1) #6-1/0 CU; (1) #4 1/0 (1) #6-1/0 CU; #4-1/0 AL (1) #6-1/0 CU; #4-1/0 AL (1) #6-1/0 CU; #4-1/0 AL (1) #2-2/0 CU; # 2-2/ AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL Product Number THHQL2160 THHQL2170 THHQL2180 THHQL2190 THHQL21100 THHQL21110 THHQL21125 THQD22100 THQD22125 THQD22150 THQD22175 THQD22200 Use TMQD Tenant Main Circuit Breakers 42,000 AIC Socket Amps 125 125 125 125 125 125 Ampere Rating 60 70 80 90 100 125 Wire Size Load Lugs (1) #10-1/0 CU; #10-1/0 AL (1) #10-1/0 CU; #10-1/0 AL (1) #10-1/0 CU; #10-1/0 AL (1) #10-1/0 CU; #10-1/0 AL (1) #10-1/0 CU; #10-1/0 AL (1) #10-1/0 CU; #10-1/0 AL Product Number TMQL2160 TMQL2170 TMQL2180 TMQL2190 TMQL21100 TMQL21125 Wire Size Load Lugs (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL Product Number TMQD22060 TMQD22070 TMQD22080 TMQD22090 TMQD22100 TMQD22125 TMQD22150 TMQD22175 TMQD22200 TMQD22225 Tenant Main Circuit Breakers 100,000 AIC Socket Amps 200 200 200 200 200 200 200 200 200 200 Ampere Rating 60 70 80 90 100 125 150 175 200 225 1Sub-feed lug, no overcurrent protection. 2-20 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Meter Stack Modules Single-Phase Plus Accessories Accessories - Field Installed Product Number Description By-pass Kits Manual Slider-Type (Ring Type Only) -125 amp top socket for 2, 3, 5 and 6 gang -125 amp for all other sockets -200 amp for all sockets Jumper Straps Type (use with TMCA) Cover Including Jumper Strap Type-fits all (Ring Type Only) Horn-Type-fits all (Ringless Only) Fifth Jaw Kits -Bused; 3, 6, or 9 o'clock mounting: Order two for fifth and sixth jaw. Not suitable for 2-gang ring type -Isolated; 3 or 9 o'clock mounting Sealing Rings -Screw-Type, Aluminum -Snap Type, Stainless Steel -Screw and Lock-Type, Aluminum -Snap-Type, Aluminum (Standard) Steel Meter Socket Covers Blank (fits bottom position only) -125 Amp -200 Amp Ringless (Field -converts ring-type to ringless) -125 amp top socket for 2 and 3 gang -125 amp for all other sockets -200 amp for all sockets Lexan Meter socket Cover Plate (without tabs) Lexan Meter Socket Cover Plate Equipment Ground Bar, (6) 6-2/0 Individual Meter Socket Barrier Kit (includes 6) Mounting Z-Rail, 4-foot Spacer 4-inch, 4 cross bus rated 1200A Elbow 16 inch x 16 inch, 4 cross bus rated 1200A Elbow 12 inch x 12 inch, 4 cross bus rated 1200A Main Module Door Barrier Kit, Bottom Closure Kit Feed Main Anti-Inversion Clip Endwall Endwall TQD Mounting Kit TQD Breaker Mounting Kit - This is a replacement part. Units come with this part factory installed. 1Not UL Listed. 2200 amps continuous. 3100 amps continuous. 4Indoor Type 1. TMBPM12TA2 TMBPM12A2 TMBPM20A2 TMBPJ201,3 TMBPJ20 TMBPM12TA TSR1 TSR3 TMCB12B TMCR12 TMCR12T TMCP TMBPC201 TMBPH20A3 TM5JA TM5JUA TSR1 TSR3 TSR4 TSR5 TMCB12B TMCB20B TMCR12T TMCR12 TMCR20 TMCA TMCP TMEG TMBR TMZR TMPS12 TMPE124 TMPE12A4 TMP3FBB TMIC TM234BEW200 TM56BEW200 TMTQD3 TMZR TMBR Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-21 Modular Metering Section 2 Meter Mod III Meter Stack Modules Single-Phase Plus Accessories Product Features —Single-Phase/Three-Wire, 120/240 Vac or Three-Phase, Four-Wire, Horizontal Bus, 208Y/120 Vac System Voltage —UL listed —1200 amp, 4-wire cross bus (aluminum) —Front Accessible Field Phase Balancing by Meter Socket —(1) 14-2 Equipment Ground per Socket, Factory Installed —Only 225A and 400 Ringless Type meter stacks, contain lever bypass. 125A and 200A meter sockets do not contain lever bypass Ringless Type Socket w/ Lever Bypass Socket Amps 225A 225A 225A 225A 400A 400A 400A 400A TMPR12122R No. of Sockets Product Number 1 2 3 4 1 2 1 1 TMPR12122R1,5 TMPR12222R1,5 TMPR12322R1,5 TMPR12422R1,5 TMPR12140RB1,2,9 TMPR12240RB1,3,9 TMPK12140RB1 TMPK12140RBA1 No. of Sockets 1 1 1 2 2 2 3 3 3 Product Number TMP8120RTAB4,5 TMP8120RTBC4,5 TMP8120RTAC4,5 TMP112220RTAB4,5 TMP112220RTAC4,5 TMP112220RTBC4,5 TMP112320RTAB4,5 TMP112320RTAC4,5 TMP112320RTBC4,5 Ring Type Socket Socket Amps 225A 225A 225A 225A 225A 225A 225A 225A 225A One snap-type, aluminum sealing ring (TSR5) per socket included. Tenant Main Circuit Breakers 10,000 AIC Socket Amps 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 125 150 175 200 225 Wire Size Load Lugs (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL Product Number TEB122015 TEB122020 TEB122025 TEB122030 TEB122035 TEB122040 TEB122045 TEB122050 TEB122060 TEB122070 TEB122080 TEB122090 TEB122100 TQD22125 TQD22150 TQD22175 TQD22200 Use TMQD Tenant Main Circuit Breakers 22,000 AIC Socket Amps 200 200 200 200 200 200 2-22 Ampere Rating 100 125 150 175 200 225 Wire Size Load Lugs Product Number (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL THQD22100 THQD22125 THQD22150 THQD22175 THQD22200 Use TMQD BuyLog™ Catalog Tenant Main Circuit Breakers 100,000 AIC Socket Amps 200 200 200 200 200 200 200 200 200 200 Ampere Rating Wire Size Load Lugs Product Number 60 70 80 90 100 125 150 175 200 225 (1) #6-1/0 CU; # 6-1/0 AL (1) #6-1/0 CU; # 6-1/0 AL (1) #6-1/0 CU; # 6-1/0 AL (1) #6-1/0 CU; # 6-1/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL TMQD22060 TMQD22070 TMQD22080 TMQD22090 TMQD22100 TMQD22125 TMQD22150 TMQD22175 TMQD22200 TMQD22225 Accessories — Field Installed Type TEB Breaker Mounting Kit Barrel Lock Bracket and Guard Kit Bypass Kit Blank Meter Socket Cover Individual Meter Socket Barrier Kit (Includes 6) Insulator for Lever By-pass Handle Mounting Z Rail Spacer Elbow Elbow Description Product Number TMTEB TMBL6 Totalizing Jumper Type Fits all positions TMBPT3206,7 TMCB322A TMBR3 TMHN 4-foot 4 inch, 4 cross bus rated, 1200A 16 inch x 16 inch, 4 cross bus rated 1200A 12 inch x 12 inch, 4 cross bus rated 1200A TMZR TMPS12 TMPE128 TMPE12A8 1Only 225A and 400A are lever bypass. 2One 400A tenant breaker included. 3Two 400A tenant breakers included. 4Meets EUSERC requirements. T- suffix signifies test bypass kit. Suffixes AB, BC, AC reflect the factory-set phase balancing. 5Included factory-installed fifth jaw (TM5JA Bused). 6Not UL listed. 7180 amps continuous. 8Indoor, Type 1. 9See Page 2-12 for alternate 400A Rating Plugs www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Meter Mod III Meter Stack Modules Three-Phase Plus Accessories Product Features —Three-Phase/Four-Wire, 240-120 Vac; Three-Phase/Four-Wire, 208Y/120 Vac —UL listed —1200 amp, 4-wire cross bus (aluminum) —Front Accessible Field Phase Balancing by Meter Socket —(1) 14-2 Equipment Ground per Socket, Factory Installed —Swingaway Mounting Feet Factory Installed —Only 225A and 400A sockets, Ringless Type, contain lever bypass. 125A + 200A meter sockets do not contain lever bypass. TMPR312140RB Ringless Type Socket w/Lever Bypass. All units are 7-terminal except TMPK. Socket Amps No. of Sockets 225A 225A 225A 225A 400A 400A 400A 400A 400A Product Number TMPR312122R8 TMPR312222R8 TMPR312322R8 TMPR312422R8 TMPR312140TR1,8 TMPR312140RB2,8 TMPR312240RB3,8 TMPK312140RB TMPK312140RBA 1 2 3 4 1 1 2 1 1 Ring Type Socket 7-terminal units Socket Amps No. of Sockets 200A 200 A 200A Product Number TMP38120RT4,8 TMP312220RT4,8 TMP312320RT4,8 1 2 3 Tenant Main Circuit Breakers 10,000 AIC Socket Amps Ampere Rating 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 15 20 25 39 35 40 45 50 60 70 80 90 100 125 150 175 200 225 Wire Size Load Lugs Product Number (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #14-3 CU; #12-1 AL (1) #6-2/0 CU; #4-2/0 AL (1) #6-2/0 CU; #4-2/0 AL (1) #6-2/0 CU; #4-2/0 AL (1) #6-2/0 CU; #4-2/0 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL TEB132015 TEB132020 TEB132025 TEB132030 TEB132035 TEB132040 TEB132045 TEB132050 TEB132060 TEB132070 TEB132080 TEB132090 TEB132100 TQD32125 TQD32150 TQD32175 TQD32200 Use TMQD Tenant Main Circuit Breakers 22,000 AIC Socket Amps Ampere Rating 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 100 125 150 175 200 225 Wire Size Load Lugs Product Number (1) #1-300 CU; #1-300 AL (1) #1-300 CU;#1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL (1) #1-300 CU; #1-300 AL THQD32100 THQD32125 THQD32150 THQD32175 THQD32200 Use TMQD Tenant Main Circuit Breakers 100,000 AIC Socket Amps Ampere Rating Wire Size Load Lugs Product Number 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 225/400/200 60 70 80 90 100 125 150 175 200 225 (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-1/0 CU; #6-1/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #6-4/0 CU; #6-4/0 AL (1) #1/0-300 CU; 1/0-300 AL (1) #1/0-300 CU; 1/0-300 AL (1) #1/0-300 CU; 1/0-300 AL TMQD32060 TMQD32070 TMQD32080 TMQD32090 TMQD32100 TMQD32125 TMQD32150 TMQD32175 TMQD32200 TMQD32225 Accessories — Field Installed Type TEB Breaker Mounting Kit Barrel Lock Bracket and Guard Kit Bypass Kit Replacement Phase Balancing Jumper Kit Blank Meter Socket Cover Individual Meter Socket Barrier Kit (Includes 6) Insulator for Lever By-pass Handle Mounting Z Rail Spacer Elbow Elbow Description Product Number TMTEB TMBL5 Totalizing Jumper Type Fits all positions TMBPT3205,6 TMPJ315 TMCB322A TMBR3 TMHN 4-foot 4 inch, 4 cross bus rated, 1200A 16 inch x 16 inch, 4 cross bus rated 1200A 12 inch x 12 inch, 4 cross bus rated 1200A TMZR TMPS12 TMPE127 TMPE12A7 1Requires two tenant main breakers, 400 amp maximum sum of branch ratings. Cannot be used to serve a single 400A load. 2400 Amp tenant breaker included, 65 kAIC. 3Two 400 Amp tenant breakers included. 4Meets EUSERC requirements. “T” suffix indicates EUSERC test bypass kit included. 5Not UL listed. 6180 amps continuous. 7Indoor, Type 1, for inside corners only. 8These product numbers are shipped from the factory as 7-jaw units (7-terminal). Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-23 Modular Metering Section 2 Phase Balancing 125A STACKS 200A STACKS "Barrel" Shaped Phase Connector N N A A A A B B B B C C N All three-phase meter stack modules come factory connected to phase A and B, per Figure A. When connected to a 208Y/120 Vac 3-phase, 4-wire system, field phase balancing of two out of every three stacks is required. One of every three stacks should be phased AC, per Figure B, and one of every three stacks should be phased CB, per Figure C. Examples: —9 Total Positions—use (3) 3-position stacks and phase one per Figure B (A-C phasing) and one per Figure C (C-B) phasing. —16 Total Positions—use (2) 5-position and (2) 3-position stacks. Phase balance (1) 5-position per figure B (A-C phasing) and (1) 5-position per Figure C (C-B phasing). —19 Total Positions—where 4 position maximum height is allowed by utility, use (1) 4-position and (5) 3-position stacks. Phase balance (2) 3-position stacks per Figure B (A-C phasing) and (2) e-position stacks per Figure C (C-B) phasing. "Barrel" Shaped Phase Connector N A A C B "Z" Shaped Phase Connector "Z" Shaped Phase Connector FACTORY 125A A-B PHASING FACTORY 200A A-B PHASING Figure A "Barrel" Shaped Phase Connector "Barrel" Shaped Phase Connector N N A A A A B B B B C C C N N A A C C "Barrel" Shaped Phase Connector FIELD 125A A-C PHASING C "Z" Shaped Phase Connector Remove "Z" Phase Connector from "B" Phase Horizontal Bus Replace with "Barrel" Phase Connector supplied with meter stack and attach to "C" Phase Bus as shown. Torque to 60 lb-in (6.78 N-M) Retain "Z" Phase Connector for future use. "Z" Shaped Phase Connector "Barrel" Shaped Phase Connector “Z” Shaped and “Barrel Shaped Phase Connectors C B FACTORY 200A A-C PHASING Remove "Z" Phase Connector from "B" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as Shown. Torque to 60 lb-in (6.78 N-M) Figure B N N N N A A A A B B B B C C C C B "Barrel" Shaped Phase Connector C C B "Z" Shaped Phase Connector "Barrel" Shaped Phase Connector FIELD 125A C-B PHASING Remove "Barrel" Phase Connector from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) "Z" Shaped Phase Connector FACTORY 200A C-B PHASING Remove "Barrel" Phase Connector from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) Figure C 2-24 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Modular Metering Section 2 Applications Where Center-Feeding Main Module is Required SUITABLE FOR CENTER-FEED APPLICATIONS ONLY* *Horizontal bus is rated 1200 amps maximum. The load on the horizontal bus may not exceed 1200 amps in either direction from the point of connection of the main circuit breaker. Overall load is limited to the rating of the main circuit breaker. For applications where the main module ampere rating is greater than that of the meter stack horizontal bus, the main module must be placed in the middle of the lineup (Figure A). The engineer of record must provide calculations on the plans to show that the horizontal bussing will not be overloaded on either side. This situation, called “Center-Feeding”, can happen in either 800A or 1200A horizontal bus meter stack applications, depending on the main ampere rating. Refer to chart below for amperage and bus information. NOTE: Figure B shows the incorrect configurations. Does the Application Require Electrician to Center-Feed the Main Module? Amps of Main Breaker, Lug or Switch 400A – 800A 1000A 1200A 1400A 1600A 2000A 800A Horizontal Bus No Yes Yes Yes Yes Yes Main 1200A Horizontal Bus No No No Yes Yes Yes Main Main Correct Incorrect Incorrect This configuration is centered and will balance the load between left and right-side horizontal bus leaving the main section This configuration will overload the This configuration will overload the left-side horizontal bus that leaves the right-side horizontal bus that leaves main section the main section Figure A Rev. 11/13 Data subject to change without notice www.geindustrial.com Figure B BuyLog™ Catalog 2-25 Modular Metering Section 2 Mini Mod III Enclosure Knockout Dimensions Dimensions Product Number Figure No.1 Width (in inches) Height (in inches) Depth (in inches) Section A (in inches) Section B (in inches) TMM2212R, TMM2212RF TMMR2212R, TMMR2212RF, TMMR2212RHB TMM4312R, TMM4312RF TMMR4312R, TMMR4312RF, TMMR4312RHB TMM4412R, TMM4412RF TMMR4412R, TMMR4412RF, TMMR4412RHB TMM6512R, TMM6512RF TMMR6512R, TMMR6512RF, TMMR6512RHB TMM6612R, TMM6612RF TMMR6612R, TMMR6612RF, TMMR6612RHB TMM4220R TMMR4220R, TMMR4220RF, TMMR4220RHB TMM6320R, TMM6320RF TMMR6320R, TMMR6320RF, TMMR6320RHB TMM6420R, TMM6420RF TMMR6420R, TMMR6420RF, TMMR6420RHB TMM6520R TMMR6520R, TMMR6520RF, TMMR6520RHB TMM6620R TMMR6620R, TMM6620RF, TMMR6620RHB 1 1 3 3 3 3 2 2 2 2 5 5 5 5 5 5 4 4 4 4 11.88 11.88 24.25 24.25 24.25 24.25 36.28 36.28 36.28 36.28 25.50 25.50 25.50 25.50 25.50 25.50 38.75 38.75 38.75 38.75 34.56 34.56 48.31 48.31 48.31 48.31 41.59 41.59 41.59 41.59 42.69 42.69 64.56 64.56 64.56 64.56 52.44 52.44 52.44 52.44 7.56 7.56 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 7.00 18.31 18.31 21.56 21.56 12.56 12.56 12.56 12.56 12.56 12.56 18.44 18.44 30.56 30.56 18.44 18.44 18.44 18.44 18.44 18.44 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 12.13 12.13 12.13 12.13 12.13 12.13 12.13 12.13 12.13 12.13 Description Mini Mod, 1P3W, 200A MLO, (2) 125A Ring sockets Mini Mod, 1P3W, 200A MLO, (2) 125A Ringless sockets Mini Mod, 1P3W, 400A MLO, (3) 125A Ring sockets Mini Mod, 1P3W, 400A MLO, (3) 125A Ringless sockets Mini Mod, 1P3W, 400A MLO, (4) 125A Ring sockets Mini Mod, 1P3W, 400A MLO, (4) 125A Ringless sockets Mini Mod, 1P3W, 600A MLO, (5) 125A Ring sockets Mini Mod, 1P3W, 600A MLO, (5) 125A Ringless sockets Mini Mod, 1P3W, 600A MLO, (6) 125A Ring sockets Mini Mod, 1P3W, 600A MLO, (6) 125A Ringless sockets Mini Mod, 1P3W, 400A MLO, (2) 200A Ring sockets Mini Mod, 1P3W, 400A MLO, (2) 200A Ringless sockets Mini Mod, 1P3W, 600A MLO, (3) 200A Ring sockets Mini Mod, 1P3W, 600A MLO, (3) 200A Ringless sockets Mini Mod, 1P3W, 600A MLO, (4) 200A Ring sockets Mini Mod, 1P3W, 600A MLO, (4) 200A Ringless sockets Mini Mod, 1P3W, 600A MLO, (5) 200A Ring sockets Mini Mod, 1P3W, 600A MLO, (5) 200A Ringless sockets Mini Mod, 1P3W, 600A MLO, (6) 200A Ring sockets Mini Mod, 1P3W, 600A MLO, (6) 200A Ringless sockets 1Figures 2, 3 and 5 have removable drip hood and open end wall. Knockouts Symbol Conduit Size in Inches Figure 1 A B C D E F G H I J K L 1 1 – – 1 11⁄4 11⁄2 – – – – – – – – 1 11⁄4 11⁄2 2 – – – – – – – – 11⁄4 11⁄2 2 – – – – – – – 1 11⁄4 11⁄2 2 21⁄2 – – – – – – – – 11⁄2 2 21⁄2 – – – – – – – – 11⁄2 2 21⁄2 3 – – – – – – – – 2 21⁄2 3 31⁄2 – – – – – – – – 21⁄2 3 31⁄2 4 – – – – – – – – 3 31⁄2 4 – – – – – – – – – – 4 – – – – – – – – – – – 5 ⁄2 – – – – – – – – – – ⁄2 3 ⁄4 1 – – – – – – – – Figure 2 Figure 3 2-26 • Figure 4 BuyLog™ Catalog Figure 5 www.geindustrial.com Rev. 11/13 Data subject to change without notice Page Updated 04 / 2016 Modular Metering Section 2 Meter Mod III Enclosure Knockout Dimensions Dimensions Product Number Description Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (6) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (6) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (2) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (2) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (3) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (3) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (4) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (4) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (5) 125A Ring sockets, 800A horizontal bus Meter Stack, 1P3W, (5) 125A Ringless sockets, 800A horizontal bus Meter Stack, 1P3W, (2) 125A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (2) 125A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (3) 125A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (3) 125A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (4) 125A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (5) 125A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (5) 125A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (6) 125A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (4) 125A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (2) 200A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (2) 200A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (3) 200A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (3) 200A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (4) 200A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (4) 200A Ringless sockets, 1200A horizontal bus Meter Stack, 1P3W, (5) 200A Ring sockets, 1200A horizontal bus Meter Stack, 1P3W, (5) 200A Ringless sockets,1200A horizontal bus Single-Phase, Three-Wire Single-Phase, Three-Wire Single-Phase, Three-Wire Single-Phase, Three-Wire Single-Phase, Three-Wire Single-Phase, Three-Wire 225 A 225 A 225 A 225 A 225 A 225 A TMP8212R, TMP8212RF3 TMPR8212R, TMPR8212RHB2, TMPR8212RF3, TMPR8212RHBF2,3 TMP8312R, TMP8312RF3 TMPR8312R, TMPR8312RHB2 , TMPR8312RF3, TMPR8312RHBF2,3 TMP8412R, TMP8412RF3 TMPR8412R, TMPR8412RHB2, TMPR8412RF3, TMPR8412RHBF2,3 TMP8512R, TMP8512RF3 TMPR8512R, TMPR8512RHB2, TMPR8512RF3 TMP8612R, TMP8612RF3 TMPR8612R, TMPR8612RHB2, TMPR8612RF3 TMP8220R TMPR8220R, TMPR8220RHB2, TMPR8220RF3 TMP8320R, TMP8320RF3 TMPR8320R, TMPR8320RHB2, TMPR8320RF3 TMP8420R, TMP8420RF3 TMPR8420R, TMPR8420RHB2, TMPR8420RF3, TMPR8420RHBF2,3 TMP8520R, TM8520RBUS4 TMPR8520R, TMPR8520RHB2, TMPR8520RF3, TMPR8520RBUS4 TMPR8520RHBBUS2,4 TMP12212R, TMP12212RF3 TMPR12212R, TMPR12212RHB2, TMPR12412RF + (2) TMCB12B3, TMPR12212RHBF2,3 TMP12312R, TMP12312RF3 TMPR12312R, TMPR12312RHB2, TMPR12412RF + (1) TMCB12B3, TMPR12312RHBF2,3 TMP12412R, TMP12412RF3 TMPR12412R, TMPR12412RHB2 TMPR12412RF3, TMPR12412RHBF2,3 TMP12512R, TMP12512RF3 TMPR12512R, TMPR12512RHB2, TMPR12512RF3 TMP12612R, TMP12612RF3 TMPR12612R, TMPR12612RHB2, TMPR12612RF3 TMP12220R TMPR12220R, TMPR12220RHB2, TMPR12420RF + (2) TMCB20B3 TMP12320R, TMP12320RF3 TMPR12320R, TMPR12320RHB2, TMPR12420RF + (1) TMCB20B3 TMP12420R, TMP12420RF3 TMPR12420R, TMPR12420RHB2, TMPR12420RF3, TMPR12420RHBF 2,3 TMP12520R, TM12520RBUS4 TMPR12520R, TMPR12520RHB2, TMPR12520RF3, TMPR12520RBUS4, TMPR12520RHBBUS2,4 TMPR12122R TMPR12222R TMPR12322R TMPR12422R TMP8120RTAB TMP8120RTAC Figure No.1 Width (in inches) Height (in inches) Depth (in inches) Section A (in inches) Section B (in inches) 1 12.26 41.60 6.62 21.61 9.00 1 12.26 41.60 6.62 21.61 9.00 1 12.26 41.60 6.62 21.61 9.00 1 12.26 41.60 6.62 21.61 9.00 1 12.26 48.50 6.62 21.61 9.00 1 12.26 48.50 6.62 21.61 9.00 1 12.26 57.50 6.62 21.61 9.00 1 12.26 57.50 6.62 21.61 9.00 1 12.26 66.50 6.62 21.61 9.00 1 12.26 66.50 6.62 21.61 9.00 2 13.38 52.36 6.62 30.55 12.13 2 13.38 52.36 6.62 30.55 12.13 2 13.38 52.36 6.62 18.42 12.13 2 13.38 52.36 6.62 18.42 12.13 2 13.38 64.51 6.62 18.42 12.13 2 13.38 64.51 6.62 18.42 12.13 2 13.38 74.96 6.62 16.76 12.13 2 13.38 74.96 6.62 16.76 12.13 1 12.26 41.60 6.62 21.61 9.00 1 12.26 41.60 6.62 21.61 9.00 1 12.26 41.60 6.62 12.61 9.00 1 12.26 41.60 6.62 12.61 9.00 1 12.26 48.50 6.62 12.61 9.00 1 12.26 48.50 6.62 12.61 9.00 1 12.26 57.50 6.62 12.61 9.00 1 12.26 57.50 6.62 12.61 9.00 1 12.26 66.50 6.62 12.61 9.00 1 12.26 66.50 6.62 30.55 9.00 2 13.38 52.36 6.62 30.55 12.13 2 13.38 52.36 6.62 18.42 12.13 2 13.38 52.36 6.62 18.42 12.13 2 13.38 52.36 6.62 18.42 12.13 2 13.38 64.51 6.62 18.42 12.13 2 13.38 64.51 6.62 18.42 12.13 2 13.38 74.96 6.62 16.76 12.13 2 13.38 74.96 6.62 16.76 12.13 3 3 3 3 12 12 18 18 18 18 21.375 21.375 25.375 52.625 52.625 66.625 25 25 8.75 8.75 8.75 8.75 8.75 8.75 13 27 13 13 – – – 14 14 14 – – 1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall. 2Includes horn by-pass. 3”F” units have an additional cotter pin that has been added to the meter socket assembly that will keep the meter socket from detaching from the base. This change meets the new MEG requirements and should not be used outside of the state of Florida. 4Parts with “BUS” on the end have the horizontal bussing centerline on the 3rd meter rather than 2nd meter, making the unit shorter from the centerline for applications where height of top meter may be an issue. This table continued on next page. Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 2-27 Page Updated 04 / 2016 Modular Metering Meter Mod III Section 2 Enclosure Knockout Dimensions Dimensions Product Number Description Single-Phase, Three-Wire Single-Phase, Three-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Three-Phase, Four-Wire Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Breaker Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Switch Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Lug Modules Main Pull Box Modules Main Pull Box Modules Main Pull Box Modules Main Pull Box Modules Main Pull Box Modules Main Pull Box Modules Elbow Elbow 225 A 400 A 225 A 400 A 225 A 225 A 225 A 200 A 200 A 400 A TMP8120RTBC TMPR12140RB TMPR312122R TMPR312140TR TMPR312222R TMPR312322R TMPR312422R TMP312220RT TMP312320RT TMPR312140RB TMPSB4R TMP3SB4R TMPSB6R TMP3SB6R TMPSB8R TMP3SB8R TMPSB10R TMP3SB10R TMPSB12R TMP3SB12R TMPSHB4R TMP3SHB4R TMPSHB6R TMP3SHB6R TMPFT4R TMP3FT4R TMPFT6R TMP3FT6R TMPFT8R TMP3FT8R TMPFB4R TMP3FB4R TMPFB6R TMP3FB6R TMPFB8R TMP3FB8R TMPFB12R TMPFT12R TMP3FB12R TMP3FT12R TMP3FB16R TMP3FT16R TMP3FB20R TMP3FT20R TMPFB4RCLL TMPFB6RCLL TMPFB8RCLL TMPFB12RCLLT TMP3FB4RCLL TMP3FB6RCLL TMP3FB8RCLL TMP3FB12RCLLT TMPFB12RT TMP3FB12RT TMP3L4R TMP3L6R TMPL8R TMP3L8R TMPL12R TMP3L12R TMPL16R TMP3L16R TMPU4R TMP3U4R TMPU8R TMP3U8R TMPU12R TMP3U12R TMPE12 TMPE12A Figure No.1 12 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 10 10 10 10 10 10 10 10 4 4 4 4 4 4 4 4 4 5 5 4 4 4 4 6 6 7 7 8 8 11 11 Width (in inches) Height (in inches) Depth (in inches) Section A (in inches) Section B (in inches) 21.375 18 18 18 18 18 19 21.38 21.38 18 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 36.5 36.5 36.5 36.5 36.5 36.5 36.5 36.5 20 20 20 33.5 20 25.38 25.38 33.5 33.5 33.5 13.5 13.5 20 20 20 20 32.875 32.875 16.325 16.325 24.325 24.325 32.5 32.5 16 12 25 52.625 25.375 52.625 52.625 52.625 66.625 43.00 62.44 52.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 47.625 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 66.5 61 61 61 61 61 61 61 61 52.625 52.75 48.75 48.75 47.625 47.625 47.625 47.625 60.125 60.125 44.825 44.825 46.825 46.825 56.825 56.825 17.5 17.5 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.75 6.625 6.625 6.625 6.625 6.625 6.625 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 11.75 11.75 11.75 11.75 11.75 11.75 11.75 11.875 11.875 11.875 7 7 11.75 11.75 11.75 11.75 11.4375 11.4375 7.825 7.825 11.825 11.825 12 12 4.938 4.938 – 27 13 41 27 13 13 27 13 27 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 14 14 14 14 14 1Figures referenced are on pages 2-29 and 2-30. Figures 1 through 8 have a removable top drip hood. Figure 4 has a removable top drip hood and open end wall.. 2-28 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Section 2 Modular Metering Meter Mod III Enclosure Knockout Dimensions Knockouts Symbol Conduit Size in Inches • A B C D E F G H I J K L M 1 1 — — 1 11⁄4 11⁄2 — — — — — — — — 1 11⁄4 11⁄2 2 — — — — — — — — 11⁄4 11⁄2 2 — — — — — — — 1 11⁄4 11⁄2 2 21⁄2 — — — — — — — — 11⁄2 2 21⁄2 — — — — — — — — 11⁄2 2 21⁄2 3 — — — — — — — — 2 21⁄2 3 31⁄2 — — — — — — — — 21⁄2 3 31⁄2 4 — — — — — — — — 3 31⁄2 4 — — — — — — — — — — 4 — — — — — — — — — — — 5 — — — — — 2 21⁄2 3 31⁄2 4 — ⁄2 — — — — — — — — — — ⁄2 3 ⁄4 1 — — — — — — — — Rev. 11/13 Data subject to change without notice Figure 1 Figure 2 Figure 4 Figure 5 www.geindustrial.com Figure 3 Figure 6 BuyLog™ Catalog 2-29 Modular Metering Section 2 Meter Mod III Enclosure Knockout Dimensions 2-30 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice