Services for for Services Business-Critical Continuity ™ Network Infrastructure Preventive Maintenance NetPerform™ Optimization Services Take Control of Your Maintenance Budget With A NetPerform™ Preventive Maintenance Plan Emerson understands your specific needs and has developed multiple contract packages that will meet or exceed all of your requirements. Proactively catch costly emergency repairs with regular inspections of your network infrastructure. Routine maintenance increases the life of your equipment in your telecommunications infrastructure network and indentifies needed repairs and upgrades. Emerson Network Power serves as the single point of contact for all your power and facility maintenance needs allowing you to provide continuing service to your customers. All Emerson preventive maintenance plans include complete documentation of system status and recommendations for corrective steps to prevent future problems. Enjoy peace of mind with a preventive maintenance plan to keep your power equipment running at maximum efficiency and Key Features optimal reliability. Regular inspections, mainte- Network Power for all of nance and testing of equipment at scheduled intervals by experts System status report available via secure web access on the Emerson Network Power FreedomCare™ website Recommendations for required repairs and corrective actions Full service or maintenance-only programs available Multi-site customized programs available backed by experienced program managers 24X7 technical support service and field technicians to provide prompt responses Contact Emerson your maintenance needs: ESNA.FieldService@Emerson.com 800-800-5260 Frequent internal resistance testing indicates when batteries fall below 100% capacity and provides timely assessments of cell and string state of health to ensure network reliability. Guaranteed emergency on-site response time coverage available SDS-501-PM DC Power Systems and Rectifiers Visual inspection of plant and connections Measure and record system capacity and load Measure and record system voltage Verify alarm set points and operation (local and remote) Calibrate meters Thermal scan/infrared analysis Measure and record noise level Inspect filter capacitors, as applicable Ensure proper operation of LVD, if equipped Inverters Measure DC and AC voltages and currents Measure and record system capacity and load Measure and record system voltage Verify alarm set points and operation Thermal scan/infrared analysis Inspect filter capacitors, as applicable Test inverter transfer Battery Maintenance Visual inspection Tightening and torquing of connections Measurements and readings of individual cell voltage, intercell connection resistance, internal cell resistance Rehydration of flooded cells Removal of dust and dirt Calculate estimated reserve time As part of our comprehensive preventive maintenance plans, we offer on-site meter calibration to ensure proper readings to prevent costly repairs in the future. Comparative Values For The Three Battery Maintenance Techniques Estimate capacity 10 Off line discharge 8 Protect Load 6 4 2 0 Remote discharge Cost Effective Faulty cell detection Internal Resistance By combining our different battery testing and maintenance techniques shown here, you will be able to maximize yield and improve remaining life prediction accuracy. Estimate remaining life Correct mech issues SDS-501-PM Network Infrastructure Preventive Maintenance Preventive Maintenance Agreements Service Levels DC Power Systems, Rectifiers, Inverters, Converters1 Program 1 2 Preventive Maintenance Emergency Response Coverage Details Preferred Two preventive maintenance visits scheduled 7x24 Four-hour emergency response2 to locations within 150 miles of an ESNA service center. Full service coverage includes travel, labor and parts for required repairs. Essential One preventive maintenance visit scheduled 8 x 5 Four-hour emergency response2 to locations within 150 miles of an ESNA service center. Full service coverage includes travel, labor and parts for required repairs. Basic One preventive maintenance visit scheduled 8 x 5 Eight-hour emergency response2 to locations within 150 miles of an ESNA service center. Replacement parts for required repairs are included. Labor and travel for required repairs is billable on a time and material basis. PM Only 7x24 One preventive maintenance visit scheduled 7x24 Emergency response service is available on a time and material basis. All travel, labor and replacement parts for required repairs are billable on a time and material basis. PM Only 8 x 5 One preventive maintenance visit scheduled 8 x 5 Emergency response service is available on a time and material basis. All travel, labor and replacement parts for required repairs are billable on a time and material basis. Programs are subject to the terms identified in the Scopes of Work for each respective program and the General Assumptions and Terms of Conditions of Sales provided. Emergency response is defined as “site down” or “battery on discharge” situations in response to calls received by the ESNA 24/7 Technical Assistance Center at 800-800-5260. Battery Systems1 Preventive Maintenance Emergency Response Coverage Details3 Preferred Four preventive maintenance visits scheduled 7x24 Four-hour emergency response2 to locations within 150 miles of a ESNA service center. Full service coverage includes travel, labor and parts for required repairs. Replacement parts coverage is limited to minor parts only. Essential Two preventive maintenance visit scheduled 8 x 5 Four-hour emergency response2 to locations within 150 miles of a ESNA service center. Full service coverage includes travel, labor and parts for required repairs. Replacement parts coverage is limited to minor parts only. Basic One preventive maintenance visit scheduled 8 x 5 Eight-hour emergency response2 to locations within 150 miles of a ESNA service center. Travel and labor for required repairs is billable on a time and material basis. Replacement parts for required repairs are included and are limited to minor parts only. PM Only 7x24 One preventive maintenance visit scheduled 7x24 Emergency response service is available on a time and material basis. All travel, labor and replacement parts for required repairs are billable on a time and material basis. PM Only 8 x 5 One preventive maintenance visit scheduled 8 x 5 Emergency response service is available on a time and material basis. All travel, labor and replacement parts for required repairs are billable on a time and material basis. Program 1 2 3 Programs are subject to the terms identified in the Scopes of Work for each respective program and the General Assumptions and Terms of Conditions of Sales provided. Emergency response is defined as “site down” or “battery on discharge” situations in response to calls received by the ESNA 24/7 Technical Assistance Center at 800-800-5260. Battery replacement service is billable on a firm price quote or time and material basis. SDS-501-PM Network Infrastructure Preventive Maintenance Additional Equipment We Service: Emerson Network Power can also provide complete turnkey contracts for your entire network infrastructure needs including: HVAC UPS Fire Suppression VFDs Motors Lighting Generators Switchgear Additional Field Service Offerings: Battery Life Cycle Management Battery replacement service (cell level or battery string) Component upgrades including capacitor, fan and contractor replacements Emergency and scheduled repair services Energy optimization Field and depot repair services IEEE Battery capacity testing On-site troubleshooting Power system expansion including battery additions, rectifier additions or replacements, etc Remote monitoring Replacement parts Site decommissioning Site inventory & Analysis Thermography Available exclusively to our preventive maintenance customers, FreedomCare™, a secure customer website, provides the capability to view and download service and maintenance visit reports. Contact 800-800-5260 Information ESNA.FieldService@Emerson.com www.emersonnetworkpower.com/services Emerson Network Power. The global leader in enabling Business-Critical Continuity™. AC Power Embedded Power Precision Cooling Connectivity Infrastructure Management & Monitoring Racks & Integrated Cabinets DC Power Outside Plant Services Embedded Computing Power Switching & Controls Surge Protection ©2010 Emerson Network Power Energy Systems, North America, Inc. All rights reserved This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relatiing to the products or services concerned. Emerson Network Power Energy Systems 1122 F Street Lorain OH 44052 Toll Free: 800-800-5260 ESNA.FieldService@Emerson.com www.emersonnetworkpower.com/services Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Printed in the USA SDS-501-PM