NICMOS SMOV Update November 4 2009 Agenda 1. Recent Activities 2. NICMOS SMOV Program Status 3. Recent Results and Analysis - Focus Tilt measurement - Aperture Locations 4. Tentative Forward Plan 1 Recent Activity: • 11416 Thermal Background started Mon Oct 19 • 11417 Dark Monitoring and Detector Read Noise started Mon Oct 19 • Operation stopped Oct 22 due to SIC&DH lock-up Planned activities: Currently no planned activities. NICMOS/NCS warming up Outstanding issues from previous SMOV activities: — 11408:4 Update of nominal PAM Tilt settings visit 8 — SIAF update following analysis of 11410 2 NICMOS SMOV Status Activity Prop ID Title PI Visits Done Total Visits Status NIC03 11406 DC Transfer Test Schneider 2 2 Completed NIC04 11407 Filter Wheel Test Wheeler 4 4 Completed NIC05 11408 Focus/Tilt Test Wiklind 7 8 Analysis in progress (tilt) NIC06 11409 FOM Functional Dahlen 0 1 Deferred NIC07 11410 Aperture Location Koekemoer 3 3 Analysis in progress NIC08 11411 Optical Plate Scale Wiklind 0 3 Deferred NIC09 11412 Geometric Stability Wiklind 0 2 Deferred NIC10 11413 Mode-2 Coronagr. Target Acquisition Schneider 0 (5)* On Hold NIC11 11414 Optimum Coronagraphic Focus Schneider 0 (2) On Hold NIC12 11415 Coronagr. Performance Assessment Schneider 0 (5)* On Hold NIC13 11416 Thermal Characterization Barker 3 (100) On Hold NIC14 11417 Detector Read Noise and Dark Current Dahlen 14 86 On Hold New 11947 Dark Monitoring (C17 Cal Program) Dahlen 48 48 Completed *) Number of orbits changed 3 Recent Results Glenn Schneider: Airy Ring Asymmetry • Average of 7 stars • Flux normalized • Smooth • Measure intensity in 4 quadrants • Asymmetry coefficient Ax,Ay • Linear interpolation to find minimum asymmetry NIC2 (XTILT,YTILT) = (-2.1,+3.6) 4 Recent Results (XTILT, YTILT) = (0.0,+1.5) (XTILT, YTILT) = (0.0,+1.5) (XTILT,YTILT) = (-2.1,+3.6) (XTILT,YTILT) = (-2.1,+3.6) (XTILT,YTILT) = (-0.5,+0.5) (XTILT,YTILT) = (-1.5,+1.5) 5 History of optimal PAM Tilt NIC1 XTILT NIC2 YTILT XTILT YTILT SMOV2 7 12 5 10 SMOV3b 16 14 15 10 SMOV4 (suggested values) 16 14 14 12 Reason for the discrepancy between phase retrieval and Airy Ring Asymmetry not understood. However, the λ=1.7µm wavefront error within the requirement (< λ/14) for either position. Forward Plan (depending on additional SMOV activities) Leave NIC1 PAM unchanged Correct NIC2 PAM with (XTILT,YTILT) = (–1.0, +2.0) 6 Recent Results Aperture Locations • Astrometric Field (NGC188) • Three different stars • 9–point dither • Detailed analysis in progress Tentative Analysis: Compare commanded x,y pixel with observed NIC1: ΔX = –0.05” ± 0.01” ΔY = +2.26” ± 0.01” NIC2: ΔX = –0.00” ± 0.07” ΔY = +2.09” ± 0.03” NIC3: ΔX = +0.20” ± 0.18” ΔY = –0.14” ± 0.15” 7 Recent Results NIC3 : NIC1 & NIC2: No apparent change in aperture +2.2” in Y, no change in X PAM Focus change in 11408:4 +0.5mm for NIC1 & NIC2 (no focus change for NIC3) A change in the PAM focus cause the field of view to move, predominantly in the Y-direction: Field of View offsets as a function of PAM Position Camera X–shift (arcsec/mm) Y–shift (arcsec/mm) NIC1 –0.018 ± 0.0005 +3.564 ± 0.0008 NIC2 –0.027 ± 0.0010 +3.568 ± 0.0010 NIC3 –0.009 ± 0.0021 +3.626 ± 0.0330 The change in nominal PAM position for NIC1 and NIC2 corresponds to a shift ΔY = +1.78” Further results from the more detailed analysis (C. Cox) 8 Tentative Forward Plan • NCS and NICMOS safed following the SIC&DH lock-up on October 22. • No cold start of the NCS due to the potential for damage from ice contamination in the circulator loop • Discussions whether to attempt to remove the ice contamination by purging the neon in the circulator loop (one refill available) • No refill has previously been attempted • Ice contamination will force warm-up at every safing • A refill may allow operation at colder detector temperature (77.15K) Re-start of NCS and cool-down: Abbreviated NICMOS SMOV to verify functionality based on the experience from SMOV3b and SMOV4 under consideration Filter Wheel Test Focus/Tilt Dark Characterization Thermal Background (continued) 9