VEDA 600VA Compact Rack-Mounted Inverter System Parallelable, modular inverter

advertisement
AC Power for
Business-Critical Continuity™
VEDA 600VA
Compact Rack-Mounted Inverter System
Parallelable, modular inverter
with or without IEC socket.
Key Features
No single point of failure
Compact and lightweight solution
High efficiency
Description
Hot swappable
The VEDA 600VA is a ‘True Redundant System’ with disconnection capability. It is
equipped with a converter that has no less than 3 disconnecting levels in series (i.e.
electronics, relay and fuse) on its DC power port, as well as an optical isolation on the
double communication bus.
Pure sine wave on AC output
Extremely compact with total depth of 264 mm, the VEDA inverter system is designed
to ETSI standards, specifically for outdoor enclosures with a very wide T° operating range
of -25°C to +65°C.
1
ESLID103en-VEDA / 0910
VEDA 600VA
Compact Rack-Mounted Inverter System
Technical Specifications
General
EMC (immunity)
EMC (emission)
Safety
Cooling
Isolation
MTBF
Efficiency on resistive load (Typical)
Dielectric Strength DC/AC
True Redundant Systems
AC Output Specifications
Nominal Voltage (AC)*
Voltage Range (AC) (adjustable)
Voltage Accuracy
Frequency
Frequency Accuracy
Total Harmonic Distortion (resistive load)
Load Impact Recovery Time
Turn on Delay
Nominal Current
EN 61000-4
EN 55022 (Class 1)
EN 60950
Forced
Doubled
230000 hrs
Online 88%
4300Vdc
Compliant
230 V
200 – 240 V
2%
50 – 60 Hz
0.03 %
<2 %
0.4 ms
40 s
2.17 A
Protected against reverse current
3 disconnection levels on AC(out) and DC(in)
power ports (electronics, fuses, relays)
RoHS
Connection I/O
Crest Factor at Nominal Power
Compliant
Terminal block
*Operation within lower voltage networks leads to derating of power performances.
Protected against reversed polarity
Self adaptive to wide operating conditions
Comprehensive table of troubleshooting codes
AC Output Power
Nominal Output Power
600 VA @50°C
500 VA @65°C
480 W @50°C
400 W @65°C
150% 15 second
110%
Full power rating from
0 inductive to 0 capacitive
Output Power (resistive load)
Short Time Overload Capacity
Permanent Overload Capacity
Admissible Load Power Factor
Internal temperature management and switch off
DC Input Specifications
Nominal Voltage (DC)
Voltage Range (DC)
Nominal Current (at 48Vdc)
Nominal Current (at 40Vdc)
Maximum Input Current in Overload
@ 40VDC (15sec)
Voltage Ripple
2.75
With short circuit management and protection
48 V
40 - 60 V
12 A
13.5 A
21 A
Environment
Altitude Above Sea
Ambient Temperature
Storage Temperature
Relative Humidity
<4,900 Ft
-25 to 65 °C
-40 to 80 °C
95%, non condensing
Signaling & Supervision
Display
Alarms Output
Supervision
Synoptic LED
Dry contacts on shelf
Use optional devices
Weight & Dimensions
Width
Depth
Height
Weight
Material (casing)
19"
264 mm
1U
5 Kg (Shelf + 2 modules)
Coated steel
2mV
Input voltage boundaries are user selectable with T2S interface
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
Emerson Network Power
Energy Systems
Calle 10 No 145, Col. San Pedro de los Pinos
CP 01180, Del. Alvaro Obregon, Mexico, D.F.
Toll Free: 01.800.9262.777
Tel/Fax: +52-55-5809 5250
Web: EmersonNetworkPower.com/EnergySystems
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Infrastructure Management & Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
© 2010 Emerson Network Power Energy Systems,
North America, Inc. All rights reserved.
Emerson®, Emerson Network Power™, Business-Critical Continuity™,
NetSure®, NetReach™, NetSpan™ and NetXtend™ are trademarks
of Emerson Electric Co. and/or one of its subsidiaries.
Printed in USA
2
ESLID103en-VEDA / 0910
Download