AC Power for Business-Critical Continuity™ VEDA 600VA Compact Rack-Mounted Inverter System Parallelable, modular inverter with or without IEC socket. Key Features No single point of failure Compact and lightweight solution High efficiency Description Hot swappable The VEDA 600VA is a ‘True Redundant System’ with disconnection capability. It is equipped with a converter that has no less than 3 disconnecting levels in series (i.e. electronics, relay and fuse) on its DC power port, as well as an optical isolation on the double communication bus. Pure sine wave on AC output Extremely compact with total depth of 264 mm, the VEDA inverter system is designed to ETSI standards, specifically for outdoor enclosures with a very wide T° operating range of -25°C to +65°C. 1 ESLID103en-VEDA / 0910 VEDA 600VA Compact Rack-Mounted Inverter System Technical Specifications General EMC (immunity) EMC (emission) Safety Cooling Isolation MTBF Efficiency on resistive load (Typical) Dielectric Strength DC/AC True Redundant Systems AC Output Specifications Nominal Voltage (AC)* Voltage Range (AC) (adjustable) Voltage Accuracy Frequency Frequency Accuracy Total Harmonic Distortion (resistive load) Load Impact Recovery Time Turn on Delay Nominal Current EN 61000-4 EN 55022 (Class 1) EN 60950 Forced Doubled 230000 hrs Online 88% 4300Vdc Compliant 230 V 200 – 240 V 2% 50 – 60 Hz 0.03 % <2 % 0.4 ms 40 s 2.17 A Protected against reverse current 3 disconnection levels on AC(out) and DC(in) power ports (electronics, fuses, relays) RoHS Connection I/O Crest Factor at Nominal Power Compliant Terminal block *Operation within lower voltage networks leads to derating of power performances. Protected against reversed polarity Self adaptive to wide operating conditions Comprehensive table of troubleshooting codes AC Output Power Nominal Output Power 600 VA @50°C 500 VA @65°C 480 W @50°C 400 W @65°C 150% 15 second 110% Full power rating from 0 inductive to 0 capacitive Output Power (resistive load) Short Time Overload Capacity Permanent Overload Capacity Admissible Load Power Factor Internal temperature management and switch off DC Input Specifications Nominal Voltage (DC) Voltage Range (DC) Nominal Current (at 48Vdc) Nominal Current (at 40Vdc) Maximum Input Current in Overload @ 40VDC (15sec) Voltage Ripple 2.75 With short circuit management and protection 48 V 40 - 60 V 12 A 13.5 A 21 A Environment Altitude Above Sea Ambient Temperature Storage Temperature Relative Humidity <4,900 Ft -25 to 65 °C -40 to 80 °C 95%, non condensing Signaling & Supervision Display Alarms Output Supervision Synoptic LED Dry contacts on shelf Use optional devices Weight & Dimensions Width Depth Height Weight Material (casing) 19" 264 mm 1U 5 Kg (Shelf + 2 modules) Coated steel 2mV Input voltage boundaries are user selectable with T2S interface Emerson Network Power. The global leader in enabling Business-Critical Continuity™. Emerson Network Power Energy Systems Calle 10 No 145, Col. San Pedro de los Pinos CP 01180, Del. Alvaro Obregon, Mexico, D.F. Toll Free: 01.800.9262.777 Tel/Fax: +52-55-5809 5250 Web: EmersonNetworkPower.com/EnergySystems AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection © 2010 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson®, Emerson Network Power™, Business-Critical Continuity™, NetSure®, NetReach™, NetSpan™ and NetXtend™ are trademarks of Emerson Electric Co. and/or one of its subsidiaries. Printed in USA 2 ESLID103en-VEDA / 0910