O-BBS 24-1080 and 48-540 Outdoor Battery Backup System Key Features •High capacity passive hydrogen ventilation system — reliable ventilation capacity exceeding industry standards to minimize risk of hydrogen build up •Two separate compartments, battery and electronics — no risk for arcs or sparks to ignite hydrogen gas as electronics compartment is located below batteries •Outer skin made of 1/8" thick powder coated aluminum — corrosion resistant and shot gun resistant •Heavy duty foil backed insulation in battery compartment — minimizes environmental impact and cooling requirement •Multiple and flexible cable inlet positions — simple adaptability to site conditions Outside Plant for Business-Critical Continuity Description The system includes innovative temperature control for the ultimate in reliability and long life time. The O-BBS is state of the art engineering with extensive software analysis as well as extensive agency testing and verification to the highest industry standards. Further engineering focus was on installability/serviceability and cost. DC Power • +24VDC or –48VDC configurations — flexibility to connect to all common DC power voltages • Integrated Battery Breaker Module, BBM — flexibility to choose up to four feeds with circuit breakers up to 200A each Cooling and Heating •Thermoelectrical cooling/heating (Peltier) — high reliability and low maintenance cost •No refrigerants used — environmental friendly and no requirement for specialized refrigerant service technicians •DC operated cooling/heating, i.e. no AC power routing required — saves site installation cost and time •Low Voltage Disconnect device — automatic disconnect and reconnect of Peltier unit maximizes backup time and minimizes recharge time •Thermostatically controlled by solid state circuit — high reliability and precise control Application Emerson Energy Systems’ O-BBS is a high performance battery backup system for outdoor applications. Usage can be for, but not limited to: •Extended RBS/BTS/data/telecom outdoor battery backup •Replacement of diesel generator sets •Replacement of existing battery backup solution to increase system reliability and battery life •Outdoor enclosure and shelter sites OSPDS-124100 / 0207 O-BBS 24-1080 and 48-540 Outdoor Battery Backup System Specifications System Characteristics Nominal system voltage +24VDC or -48VDC Backup capacity Up to 4h at 6kW and 1.75V/cell Up to 1080Ah (+24VDC version)* Up to 540Ah (-48VDC version)* Agency approvals Telcordia GR-487-CORE and UL 50 Grounding, single point 2-hole lug for 1/4" screw and 5/8" spacing Environmental Classification Operating temperature (nominal) Maximum: 115°F (46°C) with 753 W/m2 solar load Minimum: -40°F (-40°C) Sound level 55 dB(A) at 5’ (1.5m) Hydrogen outgassing capacity 500 cc/min (less than 2% H2 concentration) Degree of protection NEMA 4 (electronics compartment) NEMA 3R (battery compartment) Earthquake Telcordia GR-63-CORE, Zone 4 Environmental Control Unit, ECU Technology Thermoelectrical (TE) modules (Peltier), forced air, closed loop, filterless, non-refrigerant Cooling and heating capacity Cooling 200W, heating 250W Thermostat control (solid state) Cooling, set point 77°F (25°C), +/- 3.5°F (2°C) Heating, set point 50°F (10°C), +/- 3.5°F (2°C) Low Voltage Disconnect (LVD) with disconnect/reconnect of ECU 25.0 / 26.0V, +/- 0.5V (+24VDC version) 50.1 / 51.0V, +/- 0.5V (-48VDC version) Repair time < 10 minutes (non-specialist) Power consumption11.2A (+24VDC version) 5.6A (-48VDC version) Enclosure Dimensions (H x W x D) 57" x 36" x 30" (1448 x 914 x 762mm) Weight 880 lbs / 400 kg (excluding batteries) 2700 lbs / 1200 kg (including batteries) Lock system 3-point, padlockable Alarms Open door (NC) High/low temperature (NO or NC) Circuit breaker tripped (NO or NC) Access Front access (rear access not required) Bug screens (on all openings) 0.1" (2.5mm) mesh hole size External material Aluminum 5052-H32, 1/8" thick External color, powder coating Medium gray, polyester semi gloss hytex Cable inlets Exchangeable cable inlet plates Conduit connections, ø11/4", ø2", ø4" etc. Cable grommets and glands, various sizes Roxtec, CF16 Safety Compliance UL UL50 CSA C22.2 60950-00 Telcordia GR-487-CORE NEMA NEMA 4 for electronics compartment and NEMA 3R for battery compartment OSPDS-124100 / 0207 O-BBS 24-1080 and 48-540 Outdoor Battery Backup System Battery Specifications Optional Equipment * Top terminal type GNB Front terminal type, 22" deep GNB M12V155FT C&D FA 12-150 EnerSys12V165F Fiamm®12 FAT 155 East Penn-Deka12AVR-150ET Northstar NSB170FT M12V90F Installation Factory installed and pre-wired Battery acid drip prevention Plastic tray for each battery Battery Breaker Module (BBM) Circuit Breakers (CB) Up to 4 CBs, 100 to 200A each Lug size (external side) Up to 4/0, 2-hole lug for 3/8" screw and 1" spacing Interrupt current 50 kAIC Safety Compliance Telcordia GR-487-CORE * Additional equipment types can be fitted. OSPDS-124100 / 0207 O-BBS 24-1080 and 48-540 Outdoor Battery Backup System State of the art engineering with extensive software analysis, testing and verification Emerson Network Power. The global leader in enabling businesscritical continuity. Emerson Network Power Energy Systems 701 N. Glenville Drive, Richardson, TX Telephone: 866-851-2565 Fax: 972-367-0066 www.EmersonNetworkPower.com/EnergySystems • • • • AC Power Connectivity DC Power Embedded Computing • • • Embedded Power Monitoring Outside Plant Power Switching & Controls • • • • Precision Cooling Racks & Integrated Cabinets Services Surge Protection © 2007 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Printed in USA OSPDS-124100 / 0207