Lenntech Fact Sheet info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Dairy Processing Sanitary Nanofiltration DK3840C The D-Series family of proprietary thin-film nanofiltration membrane elements are characterized by an approximate molecular weight cut-off of 150-300 daltons for uncharged organic molecules. Divalent and multivalent anions are preferentially rejected by the membrane while monovalent ion rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to the osmotic pressure, thus enabling D-Series nanofiltration membrane systems to operate at feed pressures below those of RO systems. The DK3840C Durasan* Elements are typically used in food related processes requiring stringent sanitary procedures. Applications include lactose desalting, deacidification and demineralization of whey and demineralization of UF permeate. Figure 1: Element Dimensions Diagram Table 3: Dimensions and Weight Dimensions, inches (cm) Model Table 1: Element Specification Spacer Mil (mm) Active Area ft2 (m2) Part Number DK3840C-30D 30 (0.76) 77 (7.15) 1206940 DK3840C-50D 50 (1.27) 58 (5.39) 1206942 Table 2: Pressure Drops Maximum Pressure Drop ∆P - psig (kPa) A B C Weight lbs (kg) DK3840C-30D 38.75 (98.43) 0.833 (2.12) 3.79 (9.6) 12 (5.4) DK3840C-50D 38.75 (98.43) 0.833 (2.12) 3.79 (9.6) 12 (5.4) Table 4: Operating and Design Parameters The DK3840C Durasan Elements feature a Durasan patented outerwrap, a selection of feed spacers, and polysulfone parts. Model Dry Boxed Membrane D-Series Thin-film membrane (TFM*) Typical Operating Pressure 70-400 psig (483-2,757 kPa) Typical Operating Process Flux 10-25 GFD (17-42 LMH) Clean Water Flux (CWF)1 14 GFD (24 LMH) @ 100 psig Maximum Pressure 600 psig (4,137 kPa) Maximum Temperature 122°F (50°C) Recommended pH Operating Range 3.0-10.0, Cleaning Range 1.0-11.0 Chlorine Tolerance 500 ppm-hours, dechlorination recommended 2 Clean water flux (CWF) is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ± 25%. Elements per Pressure Vessel 1 2 3 4 5 15 ( 103) 30 (207) 45 (310) 60 (414) 60 (414) ©2006, General Electric Company. All rights reserved. *Tr a dema r k of Genera l Elec tr ic Compa ny ; ma y be r egis ter ed in one or more c ountr ies . FS1177EN 0607