Lenntech Fact Sheet info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Sugar Processing Monosaccharide Purification Duracon* NF-2 8040C The Duracon family of proprietary thin-film nanofiltration membrane elements are characterized by an approximate molecular weight cut-off of 150300 daltons for uncharged organic molecules. Divalent and multivalent ions are preferentially rejected by the membrane while monovalent ions rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to the osmotic pressure, thus enabling Duracon nanofiltration membrane systems to operate at feed pressures below those of RO systems. Duracon D-Series membrane has an average rejection of 96% on 2000 ppm MgSO4 at 25°C and 100 psig net pressure. The Duracon NF-2 8040C Elements are typically used in food related processes requiring stringent sanitary procedures. This element is designed for processing streams previously treated by ultrafiltration or similar pretreatment. They are typically used for processing sugar solutions in food-related processes. Applications include monosacharride purification and applications requiring reduction of BOD. Table 2: Pressure Drops ∆P - psig (kPa) Active Area ft2 (m2) Part Number Duracon NF-2 8040C-35D 35 (0.89) 342 (31.8) 1227615 Duracon NF-2 8040C-50D 50 (1.27) 263 (24.4) 1207044 2 3 4 5 15 (103) 30 (207) 45 (310) 60 (414) 60 (414) Table 3: Dimensions and Weight Dimensions, inches (cm) Model Dry Boxed A B C Weight lbs (kg) Duracon NF-2 8040C-35D 40.00 (101.6) 1.125 (2.857) 7.91 (20.1)1 32 (14.53) Duracon NF-2 8040C-50D 40.00 (101.6) 1.125 (2.857) 7.91 (20.1) 1 32 (14.53) 1 The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity. Table 4: Operating and Design Parameters Table 1: Element Specification Spacer Mil (mm) 1 Figure 1: Element Dimensions Diagram The Duracon NF-2 8040C Elements feature a Durasan* patented outerwrap, a selection of feed spacers and polysulfone parts. Model Elements per Pressure Vessel Maximum Pressure Drop Membrane D-Series Thin-film membrane (TFM*) Typical Operating Pressure Typical Operating Process Flux Clean Water Flux (CWF)2 70-400 psig (483-2,757 kPa) Maximum Pressure 600 psig (4,137 kPa) Maximum Temperature 122°F (50°C) Recommended pH Operating Range 3.0-10.0, Cleaning Range 1.0-11.0 500 ppm-hours, dechlorination recommended Chlorine Tolerance 10-20 GFD (17-34 LMH) 18 GFD (30 LMH) @ 100 psig 2 Clean water flux (CWF) is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ±25%. ©2006, General Electric Company. All rights reserved. *Tr a dema r k of Genera l Elec tr ic Compa ny ; ma y be r egis ter ed in one or more c ountr ies . FS1190EN 0607