Lenntech Fact Sheet info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Sugar Processing Mineral and Acid Removal Duracon* NF-1 38040C-50P The Duracon family of proprietary thin-film nanofiltration membrane elements are characterized by an approximate molecular weight cut-off of 150300 daltons for uncharged organic molecules. Divalent and multivalent ions are preferentially rejected by the membrane while monovalent ions rejection is dependent upon feed concentration and composition. Since monovalent ions pass through the membrane, they do not contribute to the osmotic pressure, thus enabling Duracon nanofiltration membrane systems to operate at feed pressures below those of RO systems. Duracon D-Series membrane has an average rejection of 98% on 2000 ppm MgSO4 at 25°C and 100 psig net pressure. The Duracon NF-1 3840C-50P Elements are typically used in food related processes requiring stringent sanitary procedures. These elements are designed for high crossflow, daily CIP and the ability to handle suspended solids, while still maintaining element integrity. They are typically used for processing sugar solutions in food-related processes. Applications include demineralization, deacidification and sugar concentration. Table 2: Pressure Drops ∆P - psig (kPa) Active Area ft2 (m2) 2 3 4 5 15 (103) 30 (207) 45 (310) 60 (414) 60 (414) Table 3: Dimensions and Weight Dimensions, inches (cm) Model Duracon NF-1 3840C-50P Dry Boxed A B C Weight lbs (kg) 38.75 (98.43) 0.833 (2.12) 3.79 (9.6) 12 (5.4) Table 4: Operating and Design Parameters Table 1: Element Specification Spacer Mil (mm) 1 Figure 1: Element Dimensions Diagram The Duracon NF-1 3840C-50P Elements feature a Durasan* patented outerwrap, a selection of feed spacers and polysulfone parts. Model Elements per Pressure Vessel Maximum Pressure Drop Part Number Membrane D-Series Thin-film membrane (TFM*) Typical Operating Pressure 70-400 psig (483-2,757 kPa) Typical Operating Process Flux 7-20 GFD (11.9-34 LMH) Clean Water Flux (CWF)1 14 GFD (24 LMH) @ 100 psig Maximum Pressure 600 psig (4,137 kPa) Maximum Temperature 122°F (50°C) Recommended pH Operating Range 3.0-10.0, Cleaning Range 1.0-11.0 Chlorine Tolerance 500 ppm-hours, dechlorination recommended 1 Duracon NF-1 3840C-50P 50 (1.27) 53 (4.9) 1206941 Clean water flux (CWF) is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ±25%. ©2006, General Electric Company. All rights reserved. *Tr a dema r k of Genera l Elec tr ic Compa ny ; ma y be r egis ter ed in one or more c ountr ies . FS1192EN 0607