you can't miss it industry news 12 2 Traveling Wave fault location REASON International is introducing its line for Traveling Wave-based fault location in the North American market. Wave detection error due to misinterpretation of the fault is a major kind of error in many types of traveling wave-based equipment on the market. REASON has developed a very reliable method in order to record the correct traveling wave. The approach is to acquire the traveling wave data by using a very high-speed data acquisition module triggered by user-set thresholds over computed and continuously monitored values coming from signals in the fundamental frequency of the electric system. 4 3 Innovative NCT Network Computing Terminal The Toshiba Network Computing Terminal is a device for monitoring electric power systems. Utilizing an embedded real-time OS and Java Virtual Machine together with web-server and mobile agent technologies, the NCT provides synchrophasor functionality and instantaneous measurands. Setting and maintenance is achieved using a common browser. Many application are in practical use; Wide area measurement, Fault locating for multi-terminal transmission lines, Wide area disturbance recording, CB and transformer monitoring and diagnosis, Power quality monitoring, Micro-grid monitoring, Customer equipment monitoring etc. Basler Plug-n-Play Relay add Arc Flash Detection Basler Electric, the Retrofit Relay Experts have supplied several utilities and industrials users BE1-50/51B-Plug-n-Play Single-Phase Overcurrent relays over the years. The relays are direct replacements for electromechanical CO or IAC relays. They fit into existing cases, require no panel modifications or re-wiring. Panels can literally be upgraded in hours vs. days or weeks. Basler has expanded the line of Plug-n-Play Relays with two New Models; BE1-50/51B 235 (CO) and 237 (IAC) with Arc-flash Detection Capability. They incorporate a second low-set instantaneous with an independent contact that can be connected in a “maintenance” mode and meet NESC Arc Flash requirements. BE1-50/51B 237 PAC.SPRING.2009 BE1-50/51B 235 For more information visit the company's web site. 13 A B C Advanced Transformer Protection and Control 5 Recloser AREVA Substation Automation Solutions introduces the MiCOM P64X which preserves service life, and offers fast protection for transformer faults. Hosted on an advanced IED platform, the P64X incorporates differential, REF, thermal and overfluxing protection, plus backup protection for uncleared external faults. Model variants cover two & three winding transformers (including autotransformers), with up to 5 sets of threephase CT inputs. Large CT counts are common in ring bus/mesh corner applications, where the P64X summates currents to create each total winding current, easing application of backup protection. Backup overcurrent can be directionalized, where the user includes the optional 3-phase VT input in their chosen model. 6 Recloser & Sectionalizer Test Cable Solutions OMICRON electronics has developed test cables to simplify testing of distribution reclosers and sectionalizers, including their controllers and switches, for use with the CMC 356/256 test sets. Each OMICRON test cable is designed with all components necessary to make an end-to-end direct connection between the test device and the CMC to allow testing of all functionality that the manufacturer provided in their control cable. Test Cables for devices from Cooper, G&W, SEL and S&C are available along with sample test plan(s) and instructions. PAC.SPRING.2009 you can't miss it industry news 14 8 Arc-Flash Detection New Relay from SEL The SEL-751A Feeder Protection Relay from Schweitzer Engineering Laboratories is now available with arc-flash detection (AFD) capability, providing automatic protection against dangerous arc-flash events in 9 metal-clad switchgear. AFD interrupts power to the arc flash before it can cause significant damage or personal injury. Fiber-optic light sensors in the SEL-751A detect the light produced by an arc flash. To prevent Multilin 350 Feeder Protection System Intuitive & Intelligent Feeder Protection System with Advanced Communications and Diagnostics The Multilin 350 protection relay provides the utility power distribution industry with a technologically advanced, easy to use, and intuitive overcurrent (50/51) protection relay. The Multilin 350 performs primary circuit protection of medium voltage distribution feeders. The robust Multilin 350 streamlines user workflow processes and simplifies engineering tasks such as configuration, wiring, testing, commissioning, and maintenance via advanced communications and enhanced diagnostics. Mechanically designed for effortless draw out, to eliminate re-wiring, the 350 enables fast installation, simplified retrofit and reduced lifecycle cost. TM 1703 Distributed I/O Module of the TG5700 RTU Siemens Energy is announcing the introduction of the TM 1703 Distributed I/O Module to our TG5700 RTU product line. The TM 1703 improves the distributed capabilities of the TG5700 RTU by adding local IED ports, local PLC programmability and new electrical interfaces, like direct Pt-100 Ohm temperature probe inputs. Applications for the TG5700 RTU with TM 1703 I/O extend to Condition Based Monitoring, Transformer Monitoring and local Bay Controller Unit. With its advanced security features complying with NERC CIP guidelines, extensive intelligent electronic device (IED) integration capabilities and best-in-class configuration and diagnostic tools, the TG5700 becomes the premier Smart RTU and IED integration platform. PAC.SPRING.2009 false tripping, the SEL-751A looks for an overcurrent that coincides with the light flash and sends a trip signal to the circuit breaker in as fast as 2 ms. More information at SEL's web site. 7