LIEBERT INTELECOOL2 Product Specification Sheet Features/Options • Self-Contained All components are enclosed in the painted steel or optional corrosion-resistant aluminum cabinet. The standard color for the painted steel is tan, with optional colors available. • Space-Saving Design Mounted outside the shelter to save valuable space. • Range of Capacities Units are available in 2, 3, 4 and 5 ton 60Hz models, and 3, 4 and 5 ton 50Hz models. • Compressor Options A high-efficiency scroll compressor is standard on all models. It is ideal in applications where noise is a factor because of its low noise and vibration. • Optional Compressor Location • Evaporator Supply and Return Openings Match industry standard dimensions. • Easy to Install Wired, piped, charged with refrigerant and factory-tested as a LIEBERT INTELECOOL2 system to ensure trouble-free installation and startup. 2, 3, 4 and 5 Ton Models • Outside Air Options A fixed fresh air damper option allows for adding fresh air/pressurization. The Economizer option allows for cooling using outdoor air when it is cool enough to meet the room conditions. • Telecom Package “T-Pack” This configuration incorporates popular telecom options: low pressure switch, fan cycle control and low pressure bypass. Many other component options are also available. • Control/Monitor Options The Liebert Dual Unit Control™ thermostat can control two units and provides autochangeover control. Other autochangeover control options are also available. Model Number Designation Nominal BTU/Hs (1000) 0 = Standard Supply & Return Openings External Telecommunication ET 0 36 7 R P F B T P = 208/230V – 1 ph - 60 Hz S = 220/240 – 1 ph - 60 Hz A = 460V – 3 ph - 60 Hz Y = 208/230V – 3 ph - 60 Hz N = 200/230 – 3 ph - 50 Hz M = 380/415V – 3ph - 50 Hz 0 = Standard F = Fixed Outside Air Damper E = Economizer 1 0 = No Heat A = 5kW Heat B = 10kW Heat C = 15kW Heat 7 = Scroll Compressor with POE oil-R407C R = Right Compressor L = Left Compressor T = Tan, Painted Steel Panels C = Custom Color, Painted Steel Panels A = Aluminum Panels Liebert® InteleCool®2 60Hz Capacity data - 60Hz indoor ambient listed, outdoor ambient 95°F (35°C) MODEL ET024 ET036 ET048/ET348 ET060/ET360 Compressor Type Scroll Scroll Scroll Scroll 45600 (13.4) 34600 (10.2) 53800 (15.8) 37700 (11.1) 42300 (12.4) 34100 (10.0) 49800 (14.6) 36900 (10.8) 2030 (3450) 1910 (3240) 1770 (3010) 1650 (2800) 1520 (2580) 1390 (2360) 2030 (3450) 1910 (3240) 1770 (3010) 1650 (2800) 1520 (2580) 1390 (2360) 1800 (3060) 1680 (2850) 1580 (2680) 1470 (2500) 1360 (2310) 1250 (2120) 1800 (3060) 1680 (2850) 1580 (2680) 1470 (2500) 1360 (2310) 1250 (2120) 0.50 (0.37) 21x36.25x2 (1) 3/4 0.50 (0.37) 21x36.25x2 (1) 3/4 470 (213) 490 (222) 470 (213) 490 (222) 80°F DB/67°F WB (26.7°C DB/19.4°C WB) Total - BTU/H (kW) 21400 (6.3) 32900 (9.6) Sensible - BTU/H (kW) 16900 (5.0) 23800 (6.9) 75°F DB/62.5°F WB (23.9°C DB/16.9°C WB) Total - BTU/H (kW) 19900 (5.8) 30700 (9.0) Sensible - BTU/H (kW) 16400 (4.8) 23100 (6.8) Evaporator Air Flow - Dry Coil External Static Pressure, CFM (m3/hr) 0.0 - in. wg. (0.0 Pa) 930 (1580) 1300 (2210) 0.1 - in. wg. (25 Pa) 880 (1500) 1220 (2070) 0.2 - in. wg. (50 Pa) 840 (1430) 1130 (1920) 0.3 - in. wg. (75 Pa) 800 (1360) 1030 (1750) 0.4 - in. wg. (100 Pa) 730 (1240) 920 (1560) 0.5 - in. wg. (125 Pa) 650 (1100) 820 (1390) Evaporator Air Flow - Wet Coil External Static Pressure, CFM (m3/hr) 0.0 - in. wg. (0.0 Pa) 910 (1550) 1200 (2040) 0.1 - in. wg. (25 Pa) 860 (1460) 1120 (1900) 0.2 - in. wg. (50 Pa) 820 (1390) 1030 (1750) 0.3 - in. wg. (75 Pa) 780 (1320) 940 (1600) 0.4 - in. wg. (100 Pa) 710 (1210) 850 (1440) 0.5 - in. wg. (125 Pa) 620 (1050) 750 (1270) Evaporator Motor, hp (kW) 0.25 (0.19) 0.25 (0.19) Filter Sizes, in. (Quantity) 16x32.5x2 (1) 16x32.5x2 (1) Drain Connection, ID in. 3/4 3/4 Weight, lb. (kg) Standard Unit 330 (150) 330 (150) Unit with Economizer 350 (159) 350 (159) Electrical data, 60 Hz - amps 15 kW Heat* No Heat Model Volts 5 kW Heat 10 kW Heat Circ1 Circ2 Phase FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD ET0187 208/230 1 14.5 17.2 25 23.4 29.3 30 44.4 55.5 60 NA — — — — — ET0247 208/230 1 15.2 18.1 30 23.4 29.3 30 44.4 55.5 60 NA — — — — — ET0247 208/230 3 12.4 14.6 20 14.4 18 20 26.4 35 NA — — — — — ET0247 3 5.9 6.9 15 7.3 9.1 15 13.3 16.6 20 NA — — — — — ET0367 208/230 1 20.9 25.2 40 23.4 29.3 40 44.4 55.5 60 44.4 55.5 60 21 26.3 30 ET0367 208/230 3 15.8 18.8 30 15.8 18.8 30 26.4 35 38.4 50 — — — ET0367 3 8.4 10 15 8.4 10 15 13.3 16.6 20 19.3 24.1 25 — — — ET0487 208/230 1 31.9 38 50 31.9 38 50 46.2 57.8 60 46.2 57.8 60 21 26.3 30 ET0487 208/230 3 24.7 29 35 24.7 29 35 28.2 35.3 35 40.2 50.3 60 — — — ET0487 3 11.7 13.7 20 11.7 13.7 20 14.1 17.6 20 20.1 25.1 30 — — — ET0607 208/230 1 37.7 45.2 60 37.7 45.2 60 46.2 57.8 60 46.2 57.8 60 21 26.3 30 ET0607 208/230 3 28.3 33.5 50 28.3 33.5 50 28.3 35.3 50 40.2 50.3 50 — — — ET0607 3 13.8 16.3 25 13.8 16.3 25 14.1 17.6 25 20.1 25.1 30 — — — 460 460 460 460 * 15 kW heat option @ 208/230 - 1 phase requires two electrical feeds. Circuit 1 supplies the compressor, condenser, 10 kW heat and the evaporator motor. Circuit 2 supplies the remaining 5 kW heat. Liebert® InteleCool®2 2 33 33 48 50Hz Capacity data - 50Hz indoor ambient listed, outdoor ambient 35°C (95°F) MODEL ET035 ET047/ET347 ET059/ET359 Compressor Type Scroll Scroll Scroll Total - kW (BTU/H) 7.8 (26600) 11.2 (38300) 13.6 (46600) Sensible - kW (BTU/H) 6.1 (20700) 8.6 (29300) 9.5 (32400) Total - kW (BTU/H) 7.2 (24700) 10.4 (35500) 12.7 (43600) Sensible - kW (BTU/H) 6.0 (20400) 8.4 (28400) 9.2 (31600) 26.6°C DB/19.4°C WB (80°F DB/67°F WB) 23.9°C DB/16.9°C WB (75°F DB/62.5°F WB) Evaporator Air Flow - Dry Coil External Static Pressure, m3/hr (CFM) 0.0 Pa (0.0 - in. wg.) 1840 (1080) 2870 (1690) 2870 (1690) 25 Pa (0.1 - in. wg.) 1730 (1020) 2700 (1590) 2700 (1590) 50 Pa (0.2 - in. wg.) 1600 (940) 2500 (1470) 2500 (1470) 75 Pa (0.3 - in. wg.) 1460 (860) 2330 (1370) 2330 (1370) 100 Pa (0.4 - in. wg.) — — — 125 Pa (0.5 - in. wg.) — — — 3 Evaporator Air Flow - Wet Coil External Static Pressure, m /hr (CFM) 0.0 Pa (0.0 - in. wg.) 1700 (1000) 2550 (1500) 2550 (1500) 25 Pa (0.1 - in. wg.) 1590 (930) 2380 (1400) 2380 (1400) 50 Pa (0.2 - in. wg.) 1460 (860) 2240 (1320) 2240 (1320) 75 Pa (0.3 - in. wg.) 1330 (780) 2070 (1220) 2070 (1220) 100 Pa (0.4 - in. wg.) — — — 125 Pa (0.5 - in. wg.) — — — Evaporator 0.19 (0.25) 0.37 (0.50) 0.37 (0.50) Filter Sizes, in. (Quantity) Motor, kW (hp) 16x32.5x2 (1) 21x36.25x2 (1) 21x36.25x2 (1) Drain Connection, ID, in. 3/4 3/4 3/4 Standard Unit 150 (330) 213 (470) 213 (470) Unit with Economizer 159 (350) 222 (490) 222 (490) Weight, kg (lb.) Electrical data, 50 Hz - amps 15 kW Heat* No Heat Model Volts 5 kW Heat 10 kW Heat Circ1 Circ2 Phase FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD ET0357 220/240 1 18.1 21.7 35 23.4 29.3 35 44.4 55.5 60 44.4 55.5 60 21 26.3 30 ET0357 200/230 3 15.8 18.8 25 15.8 18.8 25 26.4 35 38.4 50 — — — 33 48 ET0357 380/415 3 8.4 10.0 15 8.4 10.0 15 15.3 19.1 20 22.3 27.9 30 — — — ET0477 200/230 3 23.3 27.2 35 23.3 27.2 35 28.2 35.3 35 40.2 50.3 60 — — — ET0477 380/415 3 11.7 13.7 20 11.7 13.7 20 16.1 20.1 25 23.1 28.9 30 — — — EF0597 200/230 3 28.3 33.5 50 28.3 33.5 50 28.3 35.3 50 40.2 50.3 50 — — — ET0597 380/415 3 13.8 16.3 25 13.8 16.3 25 16.1 20.1 25 23.1 28.9 30 — — — * 15 kW heat option @ 220/240 - 1 phase requires two electrical feeds. Circuit 1 supplies the compressor, condenser, 10 kW heat and the evaporator motor. Circuit 2 supplies the remaining 5 kW heat. Liebert® InteleCool®2 3 Ws CABINET DIMENSIONAL DATA J LIEBERT INTELECOOL2 2, 3, 4 & 5 TON UNITS 2-1/4" (58mm) Entrance for high volt connections 4" (102mm) Wu A supply E F K 1-11/16" (43mm) C G Entrance for low volt connections B return H L Shaded areas indicate a recommended clearance of 34" (864mm) in front and 30" (762mm) each side, or 36" (914mm) each side when mounted adjacent to another unit, for component access. For recommended minimum clearances, refer to the installation manual. See table below for dimensions. Wf 2-1/4" (58mm) D Liebert InteleCool2 dimensions, in. (mm) Dimensions, in. (mm) Model Wu Ws Wf A B C D E F G 2 Ton 37-1/8 17-3/4 38-3/4 20 20 9-3/8 9-13/32 8 20-3/4 12 (943) (451) (984) (508) (508) (238) (239) (203) (527) (305) 3 Ton 37-1/8 17-3/4 38-3/4 28 28 5-3/8 5-3/8 8 18 14 (943) (451) (984) (711) (711) (137) (137) (203) (457) (356) 4/5 Ton H J K L 25-1/16 69-3/4 36-3/16 31-5/8 (638) (1772) (919) (803) 26 (660) 69-3/4 36-3/16 31-5/8 (1772) (919) (803) 41 22-1/2 42-3/4 30-1/4 29-7/8 6-1/4 6-7/16 9-7/8 30 15-7/8 25-25/64 83 44 39-1/2 (1041) (572) (1086) (768) (759) (159) (164) (251) (762) (403) (645) (2108) (1118) (1003) Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2005 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-19505_REV3_11-12 Liebert® InteleCool®2 4