DC Power for Business-Critical Continuity™ MEDIA Inverter 1500VA – 48Vdc Key Features nDual input sources (AC & DC) MEDIA is a compact and scalable inverter providing a pure sine wave supply of AC power. nCompact and lightweight solution Description nHigh efficiency In conjunction with a DC power system, the MEDIA inverter delivers a reliable backup energy solution for AC applications. Using the latest Twin Sine Inverter (TSI) technology, this inverter provides superior energy efficiency in a compact size. nFull scalability and expandability nNo single point of failure The MEDIA inverter is designed to work from 230Vac and 48Vdc sources through AC/AC and DC/AC conversions. Unlike traditional inverters, this inverter features an AC to AC conversion process, known as Enhanced Power Conversion (EPC), that double filters the output wave form. EPC mode operates offline, assuring high efficiency of 95% without any compromise in quality or stability. By filtering current and voltage offline, EPC mode is able to operate like an online rectifier and inverter but deliver significantly better efficiency. Compared to a UPS operating in offline mode without current and voltage filtering, efficiency is the same but the rejection of grid disturbances is much higher. nTotal modularity as no external static-switch required MEDIA inverters have an in-built static switch function. Because no external static switch is needed, the inverter system is smaller, more reliable and easy to expand. As many as 32 inverter modules can be used in parallel. nHot swappable nPure sine wave on AC output nTransfer time reduced to naught An online mode is available for use during the occasional mains outage when inverters are fed by batteries. Since these inverters will almost constantly provide an efficiency of 95%, they offer the most reliable AC backup solution in the industry! Application Inverter systems are normally used for AC backup requirements in a telecom / datacom site or anywhere a highly reliable AC power back up source is needed. EN312DRA-Media / 1112 1 MEDIA Inverter Inverter Power Flow Diagram Standard Feature – Offline Mode AC in ➡ DC in AC Backup Feature – Online Mode ➡ AC in AC out AC ➡ DC Output power comes from AC in – Inverter is fed from AC commercial grid AC AC out DC in ➡ AC DC ➡ ➡ Output power comes from DC in – Inverter is fed from the DC Power system Technical Specifications General EMC (immunity) EMC (emission) Safety Cooling Isolation MTBF Efficiency (Typical) Dielectric Strength True Redundant Systems RoHS Connection Trouble-Free Operation EN61000-4 EN55022 (Class A in system) IEC 60950-1 Forced Doubled >200,000 hrs Enhanced power conversion 95% On line 91% DC/AC 4300Vdc Compliant: 3 disconnection levels on AC out and DC in Power ports: 4 disconnection levels on AC in port Compliant I/O terminal block protected against inversion of polarity Self adaptive to wide operating conditions and comprehensive table of troubleshooting codes AC Output Power Nominal Output Power Output Power (resistive load) Short Time Overload Capacity Permanent Overload Capacity Admissible Load Power Factor Internal Temperature Mgmt. 1500VA 1200W 150% 5 second 110% Full (power rating from 0 inductive to 0 capacitive) Switch off DC Input Specifications Nominal Voltage (DC) Voltage Range (DC) Current (at 40Vdc) Maximum Input Current Recommended Protection Voltage Ripple Input Voltage Boundaries 48 V 40 - 58 V 34A 48A 50A circuit breaker per inverter <2mV User selectable AC Input Specifications Nominal Voltage (AC) Voltage Range (AC) Current (at 185Vac) Conformity Range Power Factor Frequency Range (selectable) Synchronization Range 230 V 185 - 265 V 28A per shelf Adjustable >99% 50 - 60 Hz 47 - 53 Hz, 57 - 63 Hz AC Output Specifications Nominal Voltage (AC)* Voltage Range (AC) Voltage Accuracy Frequency Frequency Accuracy Total Harmonic Distortion (resistive load) Load Impact Recovery Time Turn On Delay Nominal Current Crest Factor at Nominal Power (with short circuit mgmt. and protection) Short Circuit Clear up Capacity** 230 V 200 - 240 V 2% 50 - 60 Hz 0.03 % <3% 0.4 ms 40 s 6.6A (protected against reverse current) 2.8: 1 10 x In for 20msec * Operation within lower voltage networks leads to derating of power. ** Available while Mains is available at AC input port, with magnitude control and management. Transfer Performance Maximum Voltage Interruption 0s Total Transient Voltage Duration (max) 0 s Environment Altitude Above Sea Ambient Temperature Storage Temperature Relative Humidity <1500m -20 to 50 °C -40 to 70 °C 95%, non-condensing Signaling & Supervision Display Alarms Output Supervision Synoptic LED Dry contacts on shelf Use optional devices Weight & Dimensions Width x Depth x Height Weight Material (casing) 19" x 2U rack x 380mm depth N x 2.4kg (inverter) + 5.5kg (rack) Coated steel EmersonNetworkPower.com/EnergySystems (North America) EmersonNetworkPower.eu/EnergySystems (EMEA) © Emerson Network Power Energy Systems North America 2012. Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and trademarks of Emerson Electric Co. EnergyMaster ™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure® and NetXtend™ are trademarks of Emerson Network Power Energy Systems North America. 2 EN312DRA-Media / 1112