Ensuring The High Availability
Of Mission-Critical Data And Applications.
About Emerson Network Power
AC Power
Locations
Emerson Network Power, a business of Emerson (NYSE:EMR), is
Emerson Network Power
Global Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229, USA
Tel: +1 614 8880246
the world’s leading provider of critical infrastructure technologies
and life cycle services for information and communications
technology systems. With an expansive portfolio of intelligent,
rapidly deployable hardware and software solutions for power,
thermal and infrastructure management, Emerson Network Power
enables efficient, highly-available networks.
Emerson Network Power
Europe Middle East And Africa
Learn more at www.EmersonNetworkPower.eu
AC Power
Customer Experience Center
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
ACpower.NetworkPower.EMEA@Emerson.com
Thermal Management
Customer Experience Center
Via Leonardo Da Vinci, 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
ThermalManagement.NetworkPower.Eu@Emerson.com
While every precaution has been taken to ensure accuracy and completeness
herein, Emerson assumes no responsibility, and disclaims all liability,
for damages resulting from use of this information or for any errors or omissions.
Specifications subject to change without notice.
MKA4L0UKCECAC Rev.1-03/2015
Emerson Network Power.eu
Follow us on Social Media:
Emerson. Consider it Solved, Liebert®, SmartAisle™, Trellis™, Trinergy™, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson
Electric Co. or one of its affiliated companies ©2015 Emerson Electric Co. All rights reserved.
AC Power
Forging Performance into Excellence
3 Customer Validation Area
Emerson Network Power’s state-of-the-art Customer Experience Center located in Castel Guelfo (Bologna - Italy), enables
our customers to experience first-hand a wide variety of data center technologies, supported by constant consultation from
R&D and engineering specialists.
Our Customer Experience Center offers
three validation experiences:
By offering our customers the industry’s largest power system testing facility in Europe, we provide them with the peace of
mind that our products perfectly match their most critical power requirements.
·· Demo - carried out on new products to
demonstrate UPS performance.
Customers visiting the center will be able to witness pre-installation demonstrations, covering the technical performance,
interoperability and efficiency of Emerson UPS systems under real field conditions.
·· Standard - validation test showing UPS
standard technical performances in
compliance with standard UPS testing
procedure.
These processes can be experienced from the facility’s control room, where real-time performance measurements and
reporting will be available while providing full visibility of the demonstration area. The center can host simultaneous tests at
full load of up to 4000 A.
·· Customized - session tailored to
validate customer’s specific technical
performance needs based on dedicated
UPS testing procedures agreed with the
customer in advance.
The customer validation area specifically dedicated to UPS consists of four testing stations, each one providing up to
1.2 MVA of capacity. Testing includes individual modules, as well as complete power systems, with the added
possibility of the customer’s switchgear support systems being connected, thus guaranteeing smooth,
rapid installation and commissioning of large power systems. Testing is also customized based
on the complexity, size and number of UPS components in the configuration.
In addition to the typical UPS system
verifications and capability testing we offer,
there are:
Steady-state Tests
·· Alarms and display verification
·· Efficiency
·· Input THDi & PF
1 Showroom
3
The Customer Experience Center
Showroom is specifically designed for
customers to interact with AC Power
units including Trinergy™ (200-1600 kW),
Liebert® APM (30-150 kW), Liebert® GXT3
(700-10000 VA), and Liebert® PSI (7503000 VA), together with other products
of the Emerson Network Power offering
(Liebert® PCW, Liebert® PDX, Liebert® CRV,
SmartAisle™, Trellis™ demo).
··
··
··
··
Output THDv
Balanced load
Unbalanced load
High Non Linear Load
Dynamic Tests
·· Main failure
·· Main restore
·· Rectifier walk-in
·· Load transfer bypass to inverter & the
opposite
·· Load step up / step down
·· Output short circuit
·· Output overload
·· Parallel module tests
Optional Tests
·· Module and system internal fault testing
such as component failures or power
supply failures
·· Battery discharge simulation
·· Integrated tests with UPS, switchboards,
downstream static transfer switches,
power distribution, etc.
·· Integrated multi bus sync testing with
multiple UPS systems
·· High resistance ground
·· Key interlock systems
·· Module and system level full load heat
runs
·· Thermal scanning
·· EMI
·· Input voltage and frequency variation
·· Monitoring options
2
1
2 Meeting Area
4 The Academy
4
Welcome Area
The Academy is designed with the purpose
of investing in Emerson Network Power’s
greatest asset: People. The Academy offers
value by providing business specific training
courses and innovative learning solutions
to develop the knowledge and skills of
Emerson Network Power employees.
The Customer Experience Center Meeting
Area features several meeting rooms and is
specifically designed for customers to meet
with Emerson Network Power product and
technology experts.