Liebert ® HPC-S™ Freecooling Chiller Designed for the Efficient Cooling of Small Data Centers Getting To A PUE Of 1.2 Freecooling data center chillers are designed to efficiently supply chilled water to indoor data center thermal management equipment. The Liebert iCOM control system is easily networked to The integrated freecooling technology used by the Liebert® HPC-S™ Freecooling Chiller allows it to cool water when the external ambient temperatures are below the chilled water return temperature.This reduces annual energy consumption of the entire chilled water system by over 30% in most applications, while improving system availability at the same time. Additionally, coupling the Liebert CRV™ Optimized Aisle The Liebert® HPC-S Freecooling Chiller provides reliable year-round capacity, regardless of the environmental working conditions, with extended high ambient capability and freecooling functionality that eliminates the need for low ambient compressor starting. The unit is equipped with the latest technology by using EC condenser fans, Copeland® scroll compressors and Liebert iCOM™ control system. provide efficient control of the chiller plant without the need for a separate building automation system. Control™ with cold aisle containment and the Liebert HPC-S Chiller creates a system capable of achieving a mechanical PUE of 1.20. This configuration thus ensures that each watt of power is used to cool the servers, hence delivering maximum availability. The chiller operates with R410A refrigerant to meet today’s data center demands by enabling businesses to operate with maximized availability and efficiency. Liebert HPC-S Chiller features: EC Fans High efficiency EC motors deliver a 25% reduction in energy consumption compared to traditional AC motors. Scroll Compressor Liebert HPC-S Chiller is equipped with Copeland digital scroll compressors to improve efficiency and reliability of performance. Liebert iCOM control Advanced unit and teamwork control to maximize energy efficiency. Fast Start Ramp Liebert HPC-S Fast Start Ramp ensures full restoration of chiller capacity after 100 seconds from power re-start. Operation It operates at extreme ambient and water temperature conditions. Freecooling Integrated freecooling functionality delivers additional energy savings and greater reliability. Refrigerant Optimized for R410A refrigerant. 2 High Efficiency High efficiency design resulting from the use of a combination of the best technologies on the marketintegrated economizer, wide operating range, and EC condenser fans. Extremely Low Noise Audible noise is minimized as a result of low-noise, HyBlade EC Fans. Achieving Efficiency And Environmental Responsibility Today, environmental responsibility is becoming increasingly fundamental for many organizations. Liebert® HPC-S™ Freecooling Chiller enables data centers to achieve increased efficiency while reducing environmental impact, through its ability to work in freecooling mode. This operation leverages the external environmental conditions to cool the water, thus requiring compressor operation only when the outside temperature exceeds the temperature of the water returning to the chiller. This occurs during more than 50% of the annual operating hours for most of the US. 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 0 -10 $50,000 Std Chiller 45˚F-55˚F Annual Operations Cost ($) Annual Power Consumption (kW-hr) Compressor operation is also used as partial back up during the partial freecooling mode. The total combined effect of the Liebert HPC-S unit’s leading technologies delivers up to 40% annual energy savings over standard industry cooling chillers. HPC-S Chiller 45˚F-55˚F HPC-S Chiller 54˚F-66˚F HPC-S Chiller 66˚F-78˚F $40,000 $30,000 $20,000 $10,000 $0 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (˚F) Std Chiller 45˚F-55˚F HPC-S Chiller 45˚F-55˚F HPC-S Chiller 54˚F-66˚F HPC-S Chiller 66˚F-78˚F Ambient Temperature (˚F) Depending on local ambient temperatures and operating temperature, Liebert HPC-S Chiller could consume thousands of kilowatts less energy than a standard chiller. This higher efficiency operation could result in thousands of dollars of energy savings every year. FG0052 FG0080 FB0110 192 kW (55) tons 285 kW (81) tons 362 kW (103) tons 61 kW 99 kW 150 kW Ambient Temperature for 50% freecooling 54°F (12°C) 51°F (10.7°C) 48°F (9°C) Ambient Temperature for 100% freecooling 39°F (4.2°C) 35°F (1.9°C) 30°F (-1°C) Chicago $12,000 $16,300 $22,600 Minneapolis $11,100 $15,100 $20,900 Denver $12,700 $17,300 $24,100 St.Louis $8,700 $11,700 $16,200 Capacity1 Power Consumption, kW Annual savings with freecooling2 1 2 Capacity at 95°F ambient air, 56°F (13.3°C) leaving fluid temperature, 12°F (6.7°C) fluid temperature rise, and 20% ethylene glycol Assumes electrical power cost of $0.10 / kWh blended rate 3 Emerson Network Power Global Headquarters Liebert® HPC-S™ Freecooling Chiller FG0 080 & FB0 110 with Integral Freecooling and Without Buffer Tank 51.2in 1300mm Right Side Left Side Electrical Panel and Control Unit Panel 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) Contact@EmersonNetworkPower.com Emerson Network Power Caribbean and Latin America Office – United States of America +1-954-984-3452 Phone Ask.Cala@Emerson.com Emerson Network Power Canada 88.2in 2240mm 226.4in 5750mm Front View Refrigerant Circuit Rear View Condenser Coil Air Inlet 3580 Laird Rd Unit 1 Mississauga Ontario L5L 5Z7 +1 905 569 8282 Ask@EmersonNetworkPower.com liebert.com 24 x 7 Tech Support Piping Connection 800 222 5877 Phone 614 841 6755 (outside U.S.) EmersonNetworkPower.com FG0 052 with Integral Freecooling and Without Buffer Tank 51.2in 1300mm Left Side Right Side Electrical Panel and Control Unit Panel While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. All names and logos referred to herein are trade names, trademarks or registered trademarks of their respective owners. ® Liebert is a registered trademark of the Liebert Corporation. © 2014 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. SL- 17600 (R01/14) 88.2in 2240mm Front View Refrigerant Circuit 187in 4750mm Rear View Condenser Coil Air Inlet Piping Connection Printed in USA