DC Power for Business-Critical Continuity™ NetSure® DCS 48375 DC-DC Converter System Key Features nModular design — provides for system redundancy and easy expansion of operating capacity in small increments Compact, cost effective, modular design, ideal for +24 VDC applications requiring -48 VDC output. nCompact shelf — 23" and 19" mount versions nExpandable — combine up to 3 shelves for 375 amp ultimate capacity and up to 60 bullet positions nHot insertion capability — allows for system expansion without disruption nEquipped for dedicated input feed per module and dual input feed per shelf – isolated input to output nSafety compliance — NEBS Certified; UL recognized Standard Features nConverter MINOR alarm nConverter MAJOR alarm DC-DC Converter Shelf Description The NetSure® DCS 48375 modular DC to DC converter shelf provides up to 375 amps at -48 volts DC via high frequency switch mode converters rated at 1500 watts (31.25 amps) each. The modular design allows the converter’s capacity to expand as your system expands. Each DCS 48375 converter shelf can accept four individual, plug-in converter modules per shelf that can be easily installed live without system interruption. Each shelf provides 6000 watts (125A max) at -48VDC to -52VDC with 20 bullet positions (23" mount) or 15 bullet positions (19" mount) in four rack units (7") of height. Application The NetSure® DCS 48375 converter shelf is compact and easy to expand, making it ideal for +24 VDC wireless, cellular radio and microwave sites requiring -48 VDC output. nFuse / CB alarm nCurrent limiting nOver-voltage protection nOver-temperature protection nLoad sharing for parallel operation nEasily accessible input and output connections for simplified installation Ordering Information Part Number Model Number Description 584622300 584622400 584622100 584622200 1C24481500 DCS48375 DCS48375 DCS48375 DCS48375 C24/48-1500 Main shelf, 23" Expansion shelf, 23" Main shelf, 19" Expansion shelf,19" NetSure® DC/DC converter module nTest points for output current and voltage measurement nEmergency power off 143D-NSDCS375 / 0912 1 NetSure® DCS 48375 Specifications Input Voltage Current Circuit Protection Filtering Efficiency Output Voltage Current Regulation Dynamic Response Filtering Protection Overvoltage Overcurrent Over Temperature 1500 Watt Converter Module 24.0 volts DC nominal, with range of 20.5 to 30.0 volts DC 83.3 amps maximum (at full load for one module, 21VDC input) Fuse is located in the positive input lead of each converter module Noise reflected back to the battery is less than 32dBrnC and is within the parameters set forth in Telcordia technical reference TR-TSY-000009, using test measurements in PUB43802, pages 5 and 6 90.8% typical -48.0 VDC, -50.0 VDC, -52.0 VDC and -54.0 VDC selectable 31.25 amps per DC-DC converter module, up to a total of 125 amps per shelf with four modules installed. Steady state output voltage remains within ±1% of the pre-adjusted voltage for any load current from no load to full load and over the specified input voltage range For a step load change within the range of 20% to 100% of full rated current, the maximum voltage transient will not exceed 5% of the initial steady state voltage Voice band noise is less than 32dBrnC. Wide band noise does not exceed 250 mV peak to peak over the frequency range of 0 to 100 MHz. Wide band noise does not exceed 50 mV rms over the frequency range of 0 Hz to 100 MHz. Each DC-DC converter module will automatically shut down and lock out should its output voltage exceed 115% to 125% of nominal voltage. Manual restart is necessary after the overvoltage condition is corrected. When the output current of a DC-DC converter module increases to a preset value between 102.5% to 115% of rated full load, the output voltage of the module will automatically decrease to limit current to this value. The output will recover to within specified limits when the overload condition is removed. Each DC-DC converter module will automatically shut down if the internal temperature of the module exceeds a predetermined value. Operation will automatically resume after the over-temperature condition is removed. Status/Alarm Indicators Minor alarm LED (yellow) and form-C contact for a single DC-DC converter module failure Shelf Major alarm LED (red) and form-C contact for two or more DC-DC converter module failures Input OK LED (green) if the input voltage source is within operating limits Fuse alarm (red) and form-C contact if any GMT load fuse opens E Stop RTN signal will shut down all converter modules Test points for output current and output voltage Module Output OK LED (green) if output voltage is between the low and high voltage alarm limits and fan is operating normally. Environmental Operating Temperature Storage Temperature Humidity Altitude Audible Noise EMI/RFI Suppression -40°C to +65°C (-40°F to +149°F), power derated to 80% at 65°C (149°F) -40°C to +85°C (-40°F to +185°F) 0% to 95% relative humidity, non-condensing Maximum operating ambient temperature should be derated linearly (3°C per 1000 ft.) at elevation above 5000 ft. The audible noise at any point 2 ft. from any vertical surface of the shelf shall not exceed 60dB-A per ANSI S1.4. This unit conforms to the requirements of FCC Part 15, Subpart B, Class B; EN55022, Class B for radiated and conducted noise; and GR-1089 CORE for conducted noise. EmersonNetworkPower.com/EnergySystems (North America) EmersonNetworkPower.eu/EnergySystems (EMEA) © Emerson Network Power Energy Systems North America 2012. Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and trademarks of Emerson Electric Co. EnergyMaster ™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure® and NetXtend™ are trademarks of Emerson Network Power Energy Systems North America. 2 143D-NSDCS375 / 0912