WSDP: MODULE 2 TOPIC 9: WATER RESOURCES 9. WATER RESOURCES Cape Town has seasonal winter rainfall runoff and therefore relies on dam and reservoir water storage to provide water throughout the year and cover peak demand in a normally dry summer. Table 1: Water resource breakdown Resource Proportion Growth in demand /annum Surface Water 98.5 % 2006/7 2007/8 2008/9 2009/10 2010/11 Ground water 1.5% 4.75% 2.29% 3.21% 1.68% 1.69% 100% The table above indicates that the key resource by is surface water and that there has been a substantial reduction in the demand growth through a number of interventions. The reliance on these two sources has kept the cost of water relatively low. 9.1. Surface Water Sources and Volumes Table 2: Surface water sources (DWA and CCT owned) Source / Storage Facility Volume in Mil m³/annum % of Total DWA Owned schemes Theewaterskloof 118 29.6% Voelvlei 70.4 17.7% Palmiet 22.5 5.6% 81 20.3% 291.9 73.2% Wemmershoek 54 13.5% Steenbras 40 10.0% Lewis Gay and Kleinplaas Dams 1.8 0.5% Land en Zeezicht Dam 1 0.3% Table Mountain Dams 3.5 0.9% Albion Springs 1.5 0.4% 5 1.3% Subtotal CCT Schemes 106.8 26.8% Total Allocation 398.7 100% Berg Rivier Subtotal DWA Schemes CCT Owned Schemes Atlantis Groundwater Scheme 3.60 9.1.1 Future Water Sources The CoCT is currently implementing a number of demand management projects with the effect that the projected time for requirement of new sources of water being moved from 2019 to 2024. Due to ageing water network the unaccounted for water for the city offers an opportunity for a considerable improvement in water saving. The improved metering of every zone will allow targeted interventions to reduce loses Ground water is a small proportion of CoCT water and does not offer major explanation into the future as a source. The risk as the result of climate change may make the recharge rate of ground water more erratic and will need extra measure in place to monitor the resource. Reclamation offers is a huge potential that has not been implemented (for cost and cultural reasons) however effluent reuse for irrigation has been taken up with little cultural resistance. Desalination as a source will continue to be a possible option but due to high cost will have to be carefully time to become a realistic option. The CoCT sells water to smaller municipalities and will factor in the management of it resource when revising their service level agreements. There is current confidence in the external sources of water which may less reliable in future as demands for increases nationally 9.1.2 Water returned to resources Wesfleur Treatment Works at Atlantis is the only WWTW which returns effluent to the source from which it was extracted (groundwater). All other treatment works have exemptions (in terms of the 1956 Water Act) from this requirement. The conditions for greater volumes of return to source will require consideration. There may be an amendment required to the Act. 3.61 9.2 Monitoring 9.2.1 Abstraction of Water Monitoring: Surface Water Abstraction is monitored with the use of bulk meters which read monthly. This is useful to calculate water balance. Some of these are read remotely, the CoCT is exploring ways of doing remote reading on a much larger scale which could dramatically help in improving water balance calculations. 9.2.2 Abstraction of Water Monitoring: Ground Water Although less than 2 % of water used in the CoCT is from ground water. It is a valuable source and is also metered and quality tested by the CoCT. 9.2.3 Abstraction of Water Monitoring: From External Water As 73.2 % of water is obtained from DWA owned schemes these are all metered and quality checked by the CoCT. 9.2.4 Abstraction of Water Monitoring: Provided to External Customers As per service level agreements all water providered to external customers monitored by the CoCT. 9.2.5 Water Levels All CoCT Dam and reservoir levels are monitored. DWA dam levels and other storage facilities are also monitored. 9.2.6 Water Quality The CoCT has achieved blue drop quality status and has established an excellent record of water quality testing by its scientific services department. There have been recent complaints about taste and water colour which has been attributed to filters at water treatment. Monitoring measures have to be put into place to limit these occurrences. 9.2.7 Boreholes Yields Bulk potable water is being used for Atlantis and is carefully monitored to prevent over extraction and to balance the recharge rate. As the cost of water increases and the improved awareness of water scarcity there are an increasing number of privately owned bore holes being used for agriculture and garden irrigation. This is use of ground water irrigation is extensively done in the Philippi agricultural area. There is a need to monitor the impact of increased levels of ground water extraction particular on environmentally sensitive areas. 3.62 9.2.8 Borehole Extraction Extraction is currently confined to less than 2% of potable water supply. Possible future sources are: TMG Aquifer Cape Flats Aquifer Newlands Aquifer West Coast Aquifer Recharge (Langebaan) 9.2.9 Compliance to Drinking Water Acceptable limits Microbiological and chemical compliance to SANS 241/2005 of the drinking water is expected to remain in the “Excellent” category. Growth in the city will require increased monitoring in the newly developed areas. As there is an ageing reticulation system in large parts of the metro, replacement and refurbishment of the network requires a large budget. As the rate of pipe bursts increases there would be an increased chance of contamination. The water main replacement and refurbishment is considered as one of the CoCT most strategic projects averaging a budget R 40 million/year. 9.2.10 Compliance to Effluent Release Acceptable Limits The CoCT has an excellent record for the treatment and testing effluent released including green drop status. The CoCT will continue to test the quality of effluent quality. Currently the CoCT is upgrading Four WWTW in order to provide acceptable levels of treatment for both release and its expanding effluent reuse programme. The WWTW being upgraded at the moment are Potdsdam, Bellville, Zandvliet and Athlone. During the up grading measures have been put in place where possible to divert some of the load to other WWTW. 9.2.11 Number of Sampling Points for Drinking Water Sufficient The CoCT has managed to achieve blue drop status with its current sampling points and will continue with this as well as add additional points as new infrastructure is installed and new areas are developed. The new bulk water augmentation scheme will produce 500Ml /day and will need a substantial number of sampling points. 3.63 Scientific Services will continue to check for improvement in the following areas: Parameters to be monitored Sampling location and frequency Sampling needs and equipment Schedules for sampling Methods of quality assurance and validation of results Responsibility and necessary qualifications of staff Requirements for documentation and the management of records Requirements for reporting and communication of results 9.2.12 The Number of Monitoring Points for Effluent Release is Sufficient Sampling and monitoring at WWTW will include inflow, outflow, process flows, Industrial effluent and sludge. Industrial effluent has been critical as there has been experience of the poisoning of treatment works resulting is a protracted period of recovery. 9.3 Water Quality 9.3.1 Reporting on Water Quality Taken from Sources: Urban The CoCT will continue to take regular sampling and report results monthly to DWA. The CoCT is committed to retaining its blue drop status will report to regularly to the public and political representatives in a transparent way. The commitment to transparency requires regularly notification in the media by: Making water quality monitoring results available in an accessible way Informing the public of any possible risks being faced Warn public of any contamination that has occurred the locality affected and precautions to be taken Educating the public on upgrades of supply system that are taking place and what is required in the future to maintain the level service as well as informing the public of the real cost of producing good quality water. Consulting public on decision making that could affect public health as well as changes in legislation or regulations. Educating the community on the for saving and conservation of water resources 3.64 9.3.2 Reporting on the Quality of Water Returned to the Resource: Urban The CoCT does operational compliance monitoring of effluent at all its WWTW in accordance to the DWA requirements for green drop certification. The sampling are done WWTW staff and testing is done by scientific services. To ensure quality of effluent the following will require regular checking: State of infrastructure Correct functioning of mechanical, electrical, instrumentation and regularity of maintenance To achieve this it is recommended that regular inspections and audits are done. The CoCT has started to implement ISO 9000, 2008 which will assist in the effort to regular inspections and audits across all sections of the Water and Sanitation department. Whether the plant is operating within the design and prescribed operational parameters. Educating the community on the for saving and conservation of water resources 9.3.3 Reporting on the Quality of Water Returned to the Resource: Rural The CoCT does not have rural cases of applying this approach. 9.3.4 Are the Water Quality Results available electronically? The CoCT makes test results available electronically and is committed to loading results on DWA’s assessment Data base. 9.4 Wet Industries The COCT encourages industry to pre-treat effluent before discharging into the sewer. The city is also rolling out treated effluent reuse many industries have taken up the opportunity to access cheaper sources of water. There some developments that managed to treat effluent on site and to reuse. 9.5 Raw Water Consumers The Bulk water branch of the CoCT has allowed raw water draw offs for agricultural purposes. 3.65 9.6 Industries and Permitted Effluent Releases Monitoring the effluent releases of all industries effectively has been a challenge for the CoCT. Although there is regular monitoring of large industries, it can sometimes be the smaller industries that relies toxic effluent that wipes out the capacity at WWTW. Policing offenders is particularly important. 3.66