1510281.GEU www.pall.com/medical Hospital Product Catalogue www.pall.com/medical 1 Pall’s Hospital Product Portfolio This catalogue showcases a selection of products that Contents can be used in hospital applications. Pall is committed to working with our customers to develop robust technologies Water Filters 3 QPoint™ 3 Pall-Aquasafe™ 5 Quick Connect Adaptors 7 Accessories - Detachable Shower Rose 9 QPData 10 PCR Technology 11 optimised to perform in their real life environments. For information on our cord blood and cell therapy products, visit www.pall.com/medical Infusion Filters 12 Pharmacy Filtration Devices 14 MIRUS™ System 15 Breathing System Filters 18 Lung Function Diagnostic Filters 20 Minimally Invasive Surgery Filters 21 Medical Gas Filters 22 www.pall.com/medical 2 QPoint™ Water Filter – Tap Assembly Product description Order code I Description Docking Station - Tap Assembly with Quick Connect Inlet QDTC Packaging Membrane area (nominal) Flow rates (nominal) 1 unit/pkg Not applicable Not applicable Diameter (nominal) Weight (nominal) Temperature 88 mm (3.5 in) 84 g (2.96 oz) Continuous influent temperature 60 °C (140 °F) during product installation Maximum influent temperature 75 °C (167 °F) for a total cumulative period of 90 minutes over the life of each connected Filter Capsule 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature Reusable External surfaces may be cleaned using common chrome compatible sanitising agents. During routine water system disinfection the Docking Station with attached Filter Capsule can be left in place to enable the outlet to be flushed Polycarbonate/Acrylonitrile Butadiene Styrene (51%), Glass Filled Nylon (22%), Polyester (20%), Stainless Steel (4%) Recycled cardboard outer packaging Maximum operating pressure Maximum life Sanitisation Main materials of construction Packaging material Filter Capsule, sterile QJ212 Jet Outlet, 0.2 μm Filter QJ22 Jet Outlet, 0.2 μm Filter 12 units/pkg - QJ212 2 units/pkg - QJ22 620 cm2 (96.1 in2) 5.7 L/min at 1 bar (1.5 gallons/min at 14.5 psi) 13.4 L/min at 3 bar (3.5 gallons/min at 43.5 psi) 18.8 L/min at 5 bar (5.0 gallons/min at 75 psi) 88 mm (3.5 in) 119 g (4.19 oz) Continuous influent temperature 60 °C (140 °F) during product installation Maximum influent temperature 75 °C (167 °F) for a total cumulative period of 90 minutes over the life of each connected Filter Capsule 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature 62 days Compatible with common surface and systemic disinfection programs. Complementary to water safety plan sanitisation and hygiene protocols Polyester (84%), Polypropylene (10%), Polyethersulphone (6%), (Recyclable) Recycled cardboard outer packaging. Ethylene Vinyl Acetate (EVA) plastic film blister. Tyvek Polyethylene lid www.pall.com/medical 3 QPoint Water Filter – Shower Assembly Product description Order code I Description Docking Station – Shower Assembly (QDS) QDS Packaging Membrane area (nominal) Flow rates (nominal) 1 unit/pkg Not applicable Not applicable Diameter (nominal) Weight (nominal) Temperature 88 mm (3.5 in) 145.6 g (5.1 oz) Continuous influent temperature 60 °C (140 °F) Maximum influent temperature 75 °C (167 °F) for a total cumulative period of 90 minutes over the life of each Filter Capsule 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature Reusable External surfaces may be cleaned using common chrome compatible sanitising agents. During routine water system disinfection the Docking Station with attached Filter Capsule can be left in place to enable the outlet to be flushed Acrylonitrile Butadine Styrene (85%), Glass Filled Nylon (9%), Polyester (2%), Stainless Steel (2%) Recycled cardboard outer packaging Maximum operating pressure Maximum life Sanitisation Main materials of construction Packaging material Shower Filter Capsule, sterile QR212 Rose Outlet, 0.2 μm Filter QR22 Rose Outlet, 0.2 μm Filter 12 units/pkg - QR212 2 units/pkg - QR22 620 cm² 5.7 L/min at 1 bar (1.5 gallons/min at 15 psi) 13.1 L/min at 3 bar (3.5 gallons/min at 44 psi) 18.8 L/min at 5 bar (5.0 gallons/min at 75 psi) 88 mm (3.5 in) 122 g (4.3 oz) Continuous influent temperature 60 °C (140 °F) Maximum influent temperature 75 °C (167 °F) for a total cumulative period of 90 minutes over the life of each Filter Capsule 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature 62 days Compatible with common surface and systemic disinfection programs. Complementary to water safety plan sanitisation and hygiene protocols Polyester (84%), Polypropylene (10%), Polyethersulphone (6%), (Recyclable) Recycled cardboard outer packaging. Ethylene Vinyl Acetate (EVA) plastic film blister. Tyvek Polyethylene lid www.pall.com/medical 4 Pall-Aquasafe™ Disposable Water Filters Product description Order code I Description Disposable Shower Head Filter for up to 31 day use, sterile AQF4 AQF42 Packaging AQF4 (12 units per case) AQF42 (2 units per case) 1,020 cm2 (158.1 in2) 31.8 L/min at 5 bar (8.4 gallons/min at 75 psi) without restricted flow connector 15 L/min at 5 bar (3,9 gallons/min at 75 psi) with restricted flow connector 240 mm (9.45 in) Membrane area (nominal) Flow rates (nominal) Length (excluding quick connect adaptor - nominal) Temperature Maximum upstream operating pressure Maximum filter life Sanitisation Continuous influent temperature 60 °C (140 °F) Maximum influent temperature 70 °C (158 °F) for a total cumulative period of 30 minutes over the life of the filter 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature 31 days Compatible with common surface and systemic disinfection programs. Complementary to water safety plan sanitisation and hygiene protocols Disposable Tap Water Filter for up to 31 day use, sterile AQ31F1S, AQ31F1S2 With smooth outlet AQ31F1R, AQ31F1R2 With shower rose AQ31F1S, AQ31F1R (12 units per case) AQ31F1S2, AQ31F1R2 (2 units per case) 550 cm2 (85.3 in2) AQ31F1S, AQ31F1S2 17.3 L/min at 5 bar (4.6 gallons/min at 75 psi) AQ31F1R, AQ31F1R2 17.4 L/min at 5 bar (4.6 gallons/min at 75 psi) AQ31F1S, AQ31F1S2 72 mm (2.8 in) AQ31F1R, AQ31F1R2 85 mm (3.4 in) Continuous influent temperature 60 °C (140 °F) Maximum influent temperature 70 °C (158 °F) for a total cumulative period of 30 minutes over the life of the filter 5 bar (75 psi) at continuous 60 °C (140 °F) influent temperature 31 days Compatible with common surface and systemic disinfection programs. Complementary to water safety plan sanitisation and hygiene protocols www.pall.com/medical 5 Pall-Aquasafe™ Disposable Water Filters (continued) Product description Order code I Description In-Line Disposable Water Filter with Quick Connect Inlet and Outlet Ports, sterile AQIN Packaging Membrane area (nominal) Flow rates (nominal) Length (excluding quick connect adaptor - nominal) 12 units per case 550 cm2 (85.3 in2) 12.8 L/min at 5 bar (3.4 gallons/min at 75 psi) 70 mm (2.76 in) Temperature Continuous influent temperature 60 °C (140 °F) Maximum influent temperature 70 °C (158 °F) for a total cumulative period of 30 minutes over the life of the filter 5 bar (75 psi) at continuous 60 °C (140 °F) Maximum upstream operating pressure Maximum filter life Sanitisation 31 days Compatible with common surface and systemic disinfection programs. Complementary to water safety plan sanitisation and hygiene protocols Disposable Tap Filter for up to 7 day use, sterile AQ7FSN With smooth outlet AQ7FRN With shower rose 12 units per case 520 cm2 (80.6 in2) 10.8 L/min at 5 bar (2.9 gallons/min at 75 psi) AQ7FSN 72 mm (2.83 in AQ7FRN 85 mm (3.35 in) Continuous influent temperature 50 °C (122 °F) Maximum influent temperature 70 °C (158 °F) for a total cumulative period of 30 minutes over the life of the filter 5 bar (75 psi) at continuous 60 °C (140 °F) 7 days Complementary to water safety plan sanitisation and hygiene protocols www.pall.com/medical 6 Quick Connect Adaptors For Water Filters – Wash Basin, In-Line and Wall Shower Applications Product description Order code I Description – Quick connect adaptor 1/2 in. female thread TAP1/2FN Without valve – Quick connect adaptor 1/2 in. female thread TAP1/2FV With valve Product description Order code I Description – Quick connect adaptor 1/2 in. male thread TAP1/2MN Without valve – Quick connect adaptor 1/2 in. male thread TAP1/2MV With valve Product description Order code I Description – Quick connect adaptor 22 mm female thread TAP22FN Without valve – Quick connect adaptor 22 mm female thread TAP22FV With valve Product description Order code I Description – Quick connect adaptor 24 mm male thread TAP24MN Without valve – Quick connect adaptor 24 mm male thread TAP24MV With valve Product description Order code I Description – Quick connect adaptor 21 mm male thread TAP21MN Without valve – Quick connect adaptor 21 mm male thread TAP21MV With valve www.pall.com/medical 7 Quick Connect Adaptors For Water Filters – Wash Basin, In-Line and Wall Shower Applications Product description – Wash basin and in-line applications – Quick connect adaptor 1/2 in. male thread SST1/2MN Stainless steel connector without valve, suitable for DI water – Wash basin and in-line applications – Quick connect adaptor 1/2 in. female thread SST1/2FV Stainless steel connector with valve, suitable for DI water Product description – Wash basin and in-line applications – Quick connect adaptor 16 mm female thread Order code I Description CVK16N Without valve – Wash basin – Only for temporary use e.g. until a threaded outlet can be installed TAPUC Universal connector (15-29 mm) Product description Order code I Description – Rotating adaptor for fixed wall shower FR2521-M24-12-ROT Rotating adaptor for PRESTO DL400 fixed wall shower – Fixed adaptor for fixed wall shower FR2521-M24-12-FIXE Fixed adaptor for PRESTO PL30 fixed wall shower Product description Order code I Description – Fixed adaptor for jet fixed wall shower FR2520-M24-TJ Fixed adaptor for DELABIE jet fixed wall shower Order code I Description www.pall.com/medical 8 Quick Connect Adaptors For Water Filters – Flexible Hose Shower Applications Product description Order code I Description – Quick connect adaptor 1/2 in. male thread SHO1/2MNN Without valve, without restrictor – Quick connect adaptor 1/2 in. male thread SHO1/2MVN With valve, without restrictor Product description Order code I Description – Quick connect adaptor 1/2 in. male thread SHO1/2MNR Without valve, with restrictor – Quick connect adaptor 1/2 in. male thread SHO1/2MVR With valve, with restrictor Accessories Product name Product description Order code I Description Packaging Maximum filter life Maximum continuous influent water temperature Maximum upstream operating pressure Pall-Aquasafe™ Detachable Shower Rose Specifically designed as an attachment to the Pall-Aquasafe Water Filter (AQ7FSN, AQ14F1S or AQ31F1S), sterile AQFROSE 25 units per case Single use following attachment to the AQ7FSN, AQ14F1S or AQ31F1S filter 40 ºC (104 ºF) 5 bar (75 psi) at continuous 40 °C (104 °F) influent temperature Product description Order code I Description – Miscellaneous shower positioning applications E135 Elbow connection, 1/2 in., 60° Product description Order code I Description – Miscellaneous sampling applications PN22C Connector for ease of water sampling www.pall.com/medical 9 QPData Product description Order code I Description Custom software data management tool for water filter traceability QPData Full Service and Support Mode (Annual Fee) QPDATA1 QPData Pre-loaded and Configured Smartphone QPDATA2 QPData Paired and Compatible Scanner QPDATA3 QPData Customer Smartphone Configuration QPDATA4 Please note: Data SIM card and/or contract is not included. The warranty of any hardware supplied by Microsec and/or Pall is limited to the Manufacturer’s warranty. Water Testing Particle Analysis in Water Distribution Systems Water distribution systems, particularly in older or large buildings may contain high levels of organic and inorganic material in the form of particles (such as, sand, silicates, rust) and colloids. Those water contaminants may contribute to biofilm formation or be derived from already established biofilm within the system. The particulate load in the water may visibly change the water colour. The turbidity of the water represents an indicator of the particulate/colloidal concentration in the system. Particulate and colloidal load in water distribution systems can be analyzed using the Silt Density Index test (SDI). Pall Medical offers SDI testing in your facilities by our specialists. Based on review of the SDI report, system specific and cost effective prefiltration technologies can be selected from a large Pall pre-filter portfolio in order to deliver maximum benefits for your water distribution system. Please contact your local Pall representative in order to find out if an SDI test can be performed in your facility. Please note: Flow reduction or blockage of POU sterilizing grade filters before their intended lifetime may indicate a high particulate load in the water distribution system. Filter Replacement Pall Medical offers a service to exchange Pall point-of-use filters and large-scale prefilter cartridges in your facility. Due to the use of quick connect adaptors, point-of-use filter exchange can be performed easily within seconds by trained cleaning or facilities maintenance staff, nursing staff, or other trained persons. However, if desired and where possible, Pall Medical offers the option to exchange filters in your facility. This can be performed using professional external technical service and cleaning companies in your area. The exchange of Pall large-scale prefilter cartridges in cooperation with the technician in your facility may also be available. Please contact your local Pall sales office in order to obtain more information about the availability of filter exchange services in your area. Turnkey Program In some locations, Pall Medical offers a Turnkey Program that includes particulate water testing, microbial water analysis, filter replacement and additional services. Please contact your local sales office in order to obtain detailed information about this program and availability of this service in your area. www.pall.com/medical 10 PCR Technology Product name Product description Ordering information Technical data Pall GeneDisc® System Real time Legionella risk management using the latest PCR technology – Quantified results within 2-3 hours, all inclusive product from sample to result, closed real-time PCR with minimised operator intervention, user-friendly software with direct display of results, simultaneous read out of Legionella spp. and L. pneumophila, seamless data transfer. Reorder code Description Sample Number Packaging EGDCV3A GeneDisc Cycler Base-Unit Single unit EGDSV3A GeneDisc Cycler Sub-Unit Single unit EGDUL1A120 GeneDisc Ultra-Lyser (US Power Supply) Single unit EGDUL1A230 GeneDisc Ultra-Lyser (EU Power Supply) Single unit EGDUP1A GeneDisc Ultra-Purifier Single unit PENVI1096 Extraction Pack Environment 1 – All water samples 96 96 units PENVI3100 Extraction Pack Environment 3 – Clear water samples 100 100 units ALEGPNE105 Standard Calibrated DNA Legionella pneumophila 5 units GLEGPNE106006 GeneDisc Pack – Legionella pneumophila Detection 30 6 plates and Quantification GLEGPNE112006 GeneDisc Pack – Legionella pneumophila Detection 66 6 plates and Quantification GLEGSPP106006 GeneDisc Pack – Legionella spp. Detection and Quantification 30 6 plates GLEGDUO106006 GeneDisc Pack - Legionella spp. and Legionella pneumophila 30 6 plates Detection and Quantification GLEGOID112006 GeneDisc Pack - Legionella spp. and Legionella pneumophila 72 6 plates Identification Total turnaround time <3 hours PCR cycle time <1 hour For information on the analytical discs, please contact your local sales office or visit www.pall.com www.pall.com/medical 11 Infusion Filters Product name Product description Order code I Description Packaging Volume Membrane Filter and tubing Special features Maximum filter life Information for use Pall Nanodyne™ ELD Filter Infusion filter with endotoxin-retentive Posidyne membrane ELD96LLCE 0.9 mm ID microbore tubing, slide clamp, luer connectors ELD96LYLE 0.9 mm ID microbore tubing, slide clamp, luer connectors, Y-injection site ELD96NTE Luer connectors, without tubing 40 units per case (ELD96NTE) 50 units per case (ELD96LLCE, ELD96LYLE) 2 mL plus tubing volume Pall Nanodyne NEO Filter Infusion filter with endotoxin-retentive Posidyne membrane and small volume NEO96E 0.5 mm ID ultra-microbore tubing, slide clamp, luer connectors NEO96NYE 0.5 mm ID ultra-microbore tubing, slide clamp, luer connectors Y-piece for needleless connection Pall Supor™ AEF Filter Infusion filter with low-protein-binding Supor membrane AEF1E 0.9 mm ID microbore tubing, slide clamp, luer connectors AEF1NTE Luer connectors, without tubing 50 units per case 50 units per case 0.4 mL 0.2 µm Posidyne membrane Non-phthalate fluid pathway, free of latex Air elimination 96 h Single patient use 0.2 µm Posidyne membrane Non-phthalate fluid pathway, free of latex Air elimination 96 h Single patient use AEF1E 1.0 mL AEF1NTE 0.7 mL 0.2 µm Supor membrane Non-phthalate fluid pathway, free of latex Air elimination 24 h Single patient use www.pall.com/medical 12 Infusion Filters (continued) Product name Product description Pall Lipipor™ TNA Filter Filter for lipid-containing solutions for parenteral nutrition Order code I Description TNA1E 0.9 mm ID microbore tubing, luer connectors Pall Lipipor TNA Filter Filter for lipid-containing solutions for parenteral nutrition – allows for infusion under gravity TNA2E 3.0 mm ID standard bore tubing, slide clamp, luer connectors Packaging Volume 50 units per case 2.3 mL 50 units per case 12 mL Membrane Filter and tubing 1.2 µm Polyamide membrane Non-phthalate fluid pathway, free of latex Air elimination 24 h Single patient use 1.2 µm Supor membrane Non-phthalate fluid pathway, free of latex Air elimination 24 h Single patient use Special features Maximum filter life Information for use Pall Lipipor NEO and Lipipor NLF Filters Infusion filters for lipid-containing solutions for parenteral nutrition in paediatric and neonatal patients NLF1E 0.9 mm ID microbore tubing, small volume, slide clamp, luer connnectors NLF2E 0.9 mm ID microbore tubing, slide clamp, luer connectors NLF1X 22.5 cm long upstream tubing, 25 cm long downstream tubing , slide clamp, luer connectors 50 units per case NLF1E 0.5 mL NLF2E 0.8 mL NLF1X 1.1 mL 1.2 µm Supor membrane Non-phthalate fluid pathway, free of latex Air elimination 24 h Single patient use www.pall.com/medical 13 Pharmacy Filtration Devices Product name Product description Order code I Description Packaging Membrane | Pore size Housing Housing diameter Connectors Membrane area Volume Free of latex Pall PharmAssure® Syringe Filter Syringe filter for drug preparation and intravenous, epidural and subcutaneous syringe bolus drug administration – Low protein binding – Extensive drug compatibility 25 mm (HP1002, HP1012, HP1050) 32 mm (HP4642, HP4644, HP4640) 50 units per case HP1002, HP4642 0.2 µm Supor membrane HP4644 0.45 µm Supor membrane HP1012 1.2 µm Supor membrane HP1050, HP4640 5.0 µm Supor membrane Acrylic 25 mm (HP1002, HP1012, HP1050) 32 mm (HP4642, HP4644, HP4640) Luer connectors (m/f) 2.8 cm2 (HP1002, HP1012, HP1050) 5.3 cm2 (HP4642, HP4644, HP4640) <0.85 mL (HP1002, HP1012, HP1050) <1.0 mL (HP4642, HP4644, HP4640) Yes Pall PharmAssure 25 mm Hydrophobic Vent Filter Vent filter for sterile venting of sterile drug containers HP2002 50 units per case 0.2 µm hydrophobic acrylic copolymer Acrylic 25 mm Luer connectors (m/f) 2.8 cm2 n/a Yes www.pall.com/medical 14 MIRUS™ System Product name Product description MIRUS™ Controller The MIRUS Controller (MC) delivers gaseous volatile anaesthetic agent via an interface line to the MIRUS Exchanger (micro re-breather) where the volatile anaesthetic agent is mixed with the inspiratory gas and delivered to the patient. It constantly measures the agent concentration and automatically maintains the target MAC. MIRUS Bottle Adaptor MIRUS Bottle Adaptor is a volatile anaesthetic agent specific key adaptor to the corresponding liquid volatile anaesthetic agent bottle and is used to fill the liquid volatile anaesthetic agent into the MIRUS Controller Order code I Description MC-M-ISO MIRUS Controller for Isoflurane MC-M-SEV MIRUS Controller for Sevoflurane MC-M-DES MIRUS Controller for Desflurane Packaging Includes 1 unit per case – 1 MIRUS Controller (Software included) – 1 Country specific power cable – 1 Quick guide – 1 Instructions for use – 1 Bottle Adaptor (according to gas) – BA-ISO-K MIRUS Bottle Adapter Isoflurane BA-DES-S MIRUS Bottle Adapter Desflurane BA-SEV-K MIRUS Bottle Adapter Sevoflurane in Safe-T-Fill◆ bottles BA-SEV-Q MIRUS Bottle Adapter Sevoflurane in Quik-Fil◆ bottles 1 unit per case – Spare parts (MC power cable) Additional parts (Quick Guide – Print) (Instructions for Use – CD) – MC-01-001 MC Power Cable Germany MC-01-002 MC Power Cable UK MC-01-003 MC Power Cable France MC-01-004 MC Power Cable Italy MC-01-005 MC Power Cable Switzerland MC-01-006 MC Power Cable Austria MC-QG-UK MIRUS Quick Guide (Print) – English MC-QG-FR MIRUS Quick Guide (Print) – French MC-QG-DE MIRUS Quick Guide (Print) – German MC-QG-IT MIRUS Quick Guide (Print) – Italian MC-IFU-CD-EIFU MIRUS Controller instruction for use (on CD) www.pall.com/medical 15 MIRUS System (continued) Product name Product description MIRUS Draining Kit Draining Kits are used to drain residual volatile anaesthetic agent from the MIRUS Controller. Clean Air Clean Air is an open reservoir scavenger system (ORS) for the evacuation of residual volatile anaesthetic gas in the expiration volume of the ventilator via the available ICU vacuum system. It has a country specific connection to the vacuum system and a specific connection to the ventilator. Order code I Description MC-01-13 MIRUS Draining Kit for Isoflurane Packaging Includes 1 unit per case – Draining bottle – Bottle cap – Draining tube with bottle cap and clamp – Allen key – Instruction for use MC-01-13-1 MIRUS Draining Kit - spare bottle – ORS-01 Clean Air (ORS) ORS-02 Clean Air (ORS) Servo edition CA-02 Vaccum Connection ORS-01-DE Clean Air vacuum connection Germany ORS-01-UK Clean Air vacuum connection UK ORS-01-FR Clean Air vacuum connection France Ventilator Adapter ORS-VC-02 Clean Air vent. connection GE Engström Carestation ORS-VC-04 Clean Air vent. connection Dräger Evita◆ 2/4/XL Ventilator ORS-VC-05 Clean Air vent. connection Dräger Evita Infinity◆ V500 Ventilator ORS-VC-06 Clean Air vent. connection Puritan Bennett◆ 840 Ventilator ORS-VC-08 Clean Air vent. connection Servo-i/u 1 unit per case – Spare parts (Draining kit) Additional parts (Instructions for Use) – ORS-01-IFU-DE Clean Air Step-by-Step IFU DE ORS-01-IFU-UK Clean Air Step-by-Step IFU UK ORS-01-IFU-FR Clean Air Step-by-Step IFU FR ORS-01-IFU-IT Clean Air Step-by-Step IFU IT www.pall.com/medical 16 MIRUS System (continued) Product name Product description MIRUS Filter Breathing system filter, designed to be used in connection with a MIRUS Reflector or for use as a “stand alone” filter in anaesthesia MIRUS Reflector Volatile anaesthetic gas rebreathing system, to be used in conjunction with a MIRUS Filter and a MIRUS Controller. Including an interface line to connect to the MIRUS Controller Order code I Description MF1 MIRUS Filter MF1D MIRUS Filter MF1 - 50 units/ case MF1D - 5 units/ case Hydrophobic media manufactured using silicone resin bonded man-made mineral fibres 50 mL 100% MR1 MIRUS Reflector >99.999% – >99.99% – <2.5 cm H2O Patient end 15 mm female / 22 mm male Machine end 22 mm female Female luer approx. 50 g Max 48h single patient use Yes <5 cm H2O Machine end 22 mm female Packaging Filter media Filter volume Filtration efficiency for liquid borne bacteria/viruses Filtration efficiency for airborne bacteria Filtration efficiency for airborne viruses Resistance @ 60 L/min Filter ISO connectors ISO monitoring port Product dry weight Recommended use Free of latex 3 units per case Shipper box: 4 cases Carbon media to reflect volatile anaesthetic agents 50 mL – – approx. 210 g Max. 7 day multiple patient use Yes www.pall.com/medical 17 Breathing System Filters Product name Product description Pall Ultipor™ 25 Breathing System Filter Breathing system filter for anaesthesia – also suitable for low tidal volumes Order code I Description BB25 With monitoring port BB25G With monitoring port (bulk pack) BB25S With monitoring port, sterile BB25GS With monitoring port, sterile (bulk pack) BB25F With monitoring port, flex tube and flex tube cap BB25FG With monitoring port, flex tube and flex tube cap (bulk pack) BB25FS With monitoring port, flex tube and flex tube cap, sterile BB25FU With monitoring port and flex tube Packaging 50 units per case (BB25, BB25S, BB25F, BB25FS, BB25FU, BB2000AP, BB25D, BB25N) 200 units per case (BB25DG, BB25DFG) 250 units per case (BB25G, BB25FG, BB25NG) 300 units per case (BB25GS) Hydrophobic media manufactured using silicone resin bonded man-made mineral fibres Bulk pack Filter media BB2000AP With monitoring port, expandable catheter mount (with two straight connectors) and catheter mount cap BB25D With monitoring port, flex tube and fixed non-ported elbow BB25DG With monitoring port, flex tube and fixed non-ported elbow (bulk pack) BB25DFG With monitoring port and flex tube bonded to a fixed, non-ported elbow BB25N With monitoring port and fixed, non-ported elbow BB25NG With monitoring port and fixed, non-ported elbow (bulk pack) Pall Ultipor 100 Breathing System Filter Breathing system filter for anaesthesia and intensive care ventilation BB100E BB100ES Sterile BB100EF With flex tube and flex tube cap BB100EFS With flex tube and flex tube cap, sterile BB100P With monitoring port BB100PS With monitoring port, sterile BB100PF With monitoring port, flex tube and flex tube cap BB100PFS With monitoring port, flex tube and flex tube cap, sterile 50 units per case – 35 mL 100% Composite media comprised, on the patient side, of a hydrophobic layer manufactured using silicone resin bonded man-made mineral fibres and, on the machine side, an integral hydrophilic cellulose layer 85 mL 100% >99.999% ≥99.999% Weight Recommended use Approx. 1.5 cm H2O Approx. 3.5 cm H2O Patient end 15 mm female / 22 mm male Machine end 22 mm female / 15 mm male 26 g Patient end use only, max. 24 h, single patient use Free of latex Yes Approx. 1 cm H2O Approx. 2 cm H2O Patient end 15 mm female / 22 mm male Machine end 22 mm female 47 g Patient end use only, max 24 h if nebulisation is used, use may be extended to a maximum of 48 hours when nebulisation is not used, single patient use Yes Filter volume Filtration efficiency for liquidborne bacteria/viruses Filtration efficiency for airborne bacteria/viruses Resistance @ 30 L/min Resistance @ 60 L/min Filter ISO connectors www.pall.com/medical 18 Breathing System Filters (continued) Product name Product description Pall BB50T Breathing System and Gas Line Filters Machine end breathing system and gas line filters Order code I Description BB50TE Machine end applications in breathing systems and gas line applications BB50TES For machine end applications in breathing systems and gas line applications (e.g., insufflation), sterile 50 units per case (BB50TE, BB50TES) Hydrophobic media manufactured using silicone resin bonded man-made mineral fibres Approx. 90 mL 100% Packaging Filter media Filter volume Filtration efficiency for liquidborne bacteria/viruses Filtration efficiency for airborne bacteria/viruses Resistance @ 30 L/min Resistance @ 60 L/min Filter ISO connectors Weight Recommended use Free of latex >99.999% Approx. 1 cm H2O Approx. 2 cm H2O Patient end 22 mm male Machine end 22 mm female 39 g BB50TE, BB50TES: Max. 24 h – in connection with a high-efficiency HME (heat and moisture exchanger) extended use may be permitted Yes www.pall.com/medical 19 Lung Function Diagnostic Filters Product name Product description Order code I Description Packaging Bulk pack Filter media Filter volume Cross contamination reduction efficiency Resistance @ 12 L/sec Connectors Weight Recommended use Free of latex Pall Pro-Tec® Filter for Pulmonary Function Testing Filter for lung function diagnostics PF30S 30 mm female connector PF30SG 30 mm female connector (bulk pack) PF30SJE Modified 30 mm female connector PF30SJG Modified 30 mm female connector (bulk pack) 25 units per case 250 units per case Polypropylene Approx. 40 mL 99.9999% Pall Pro-Tec Filter Kit for Pulmonary Function Testing Filter kit for lung function diagnostics PF30KIT1 PF30S including mouthpiece and nose clip PF30KIT2 PF30SJE including hard plastic mouthpiece PF30KIT3 PF30SJE including mouthpiece and nose clip 0.6 cm H2O 30 mm female or 30 mm modified female depending upon variant 26 g Single patient use Yes 0.6 cm H2O 30 mm female or 30 mm modified female depending upon variant 26 g Single patient use Yes 25 units per case Polypropylene Approx. 40 mL 99.9999% www.pall.com/medical 20 Minimally Invasive Surgery Filters Product name Pall Insufflator Gas Line Filter Product description Filter set for insufflation gases Order code I Description IGF1 7.5 cm silicone tubing and luer connector inlet (f), 52.5 cm silicone tubing and luer connector outlet (m), sterile double peel-pouch IGF1E 7.5 cm PVC tubing and luer connector inlet (f), 52.5 cm PVC tubing and luer connector outlet (m), sterile double peel-pouch IGF1L 7.5 cm PVC tubing and luer connector inlet (f), 250 cm PVC tubing and luer connector outlet (m), sterile double peel-pouch IGF1M 7.5 cm PVC tubing and luer connector inlet (m), 250 cm PVC tubing and luer connector outlet (f), sterile single peel-pouch IGF1C 7.5 cm PVC tubing and suction connector inlet (f), 250 cm PVC tubing and luer connector outlet (m), sterile single peel-pouch IGF1CD 7.5 cm PVC tubing and suction connector inlet (f), 250 cm PVC tubing and luer connector outlet (m), sterile double peel-pouch IGF1R 7.5 cm PVC tubing and 15 mm (m) connector at machine end and 250 cm long tubing and revolving (m) connector, sterile single peel-pouch 20 units per case Hydrophobic media manufactured using silicone resin bonded man-made mineral fibres Packaging Filter media Housing Tubing Bacteria filtration efficiency (airborne) Viral filtration efficiency for viruses (airborne) Acrylic PVC or silicone depending upon variant >99.999% >99.99% High flow insufflation set with high efficiency hydrophobic Pall gas filter Insufflator filter set for high flow applications FRIGF2 3 m PVC tubing, sterile double peel-pouch Pall LaparoShield® Laparoscopic Smoke Filtration System Filtration system for smoke generated during laparoscopic surgery LSF1 Approximately 45 cm PVC tubing and clamp, male luer connector with rotating collar, sterile double peel-pouch LSF2 Male luer connector with rotating collar, sterile double peel-pouch 20 units per case PTFE Acrylic PVC 10 units per case Pre-filtration layers - glass fibre, polyester, acrylic; Membrane layers polytetrafluoroethylene (PTFE). Chemical absorbant layers - activated carbon; Film layers - ethylene vinyl acetate (EVA) Polyester PVC, EVA >99.9999% with test organism Brevundimonas diminuta >99.999% with test organism Bacteriophage MS-2 >99.999% with test organism Brevundimonas diminuta >99.999% with test organism Bacteriophage MS-2 www.pall.com/medical 21 Medical Gas Filters Product name Product description Order code I Description Packaging Filter membrane Housing Tubing Bacteria filtration efficiency Viral filtration efficiency for viruses Pall Oxygenator Gas Line Filter Bacteria, viral and particulate removal filter for medical gases ORO1H 1/4 in. – tubing connections 40 units per case Hydrophobic media manufactured using silicone resin bonded man-made mineral fibres Acrylic n/a >99.999% (airborne) >99.99% (airborne) Pall Gas Line Filter Bacteria, viral and particulate removal filter for medical gases BRO9T 3/16 in. – tubing connection, 7.5 cm silicone tubing 100 units per case Acrylic co-polymer/Nylon, hydrophobic Silicone Yes 100% (liquidborne) 100% (liquidborne) www.pall.com/medical 22 Visit us on the Web at www.pall.com/medical Pall European Headquarters Avenue de Tivoli 3 1700 Fribourg Switzerland +41 (0)26 350 53 00 phone LifeSciences.EU@pall.com e-mail Pall Asia-Pacific Headquarters 1 Science Park Road, #05-09/15 East Wing, The Capricorn Singapore Science Park II, Singapore 117528 +65 6388 8688 phone sgcustomerservice@pall.com e-mail International Offices Pall Corporation has offices and plants throughout the world in locations such as: Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, Puerto Rico, Russia, Singapore, Spain, Sweden, Switzerland, Taiwan, Thailand, the United Kingdom, the United States, and Venezuela. Distributors in all major industrial areas of the world. To locate the Pall office or distributor nearest you, visit www.pall.com/contact This document is not for distribution in the USA. The information provided in this literature was reviewed for accuracy at the time of publication. Product data may be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly. Part numbers quoted are protected by the Copyright of Pall Europe Ltd. © 2016, Pall Corporation. Pall, , GeneDisc, Kleenpak, LaparoShield, Lipipor, Marksman, Nanodyne, Pall-Aquasafe, PharmAssure, Poly-Fine, Posidyne, Pro-Tec, QPoint, Starclear, Supor, and Ultipor are trademarks of Pall Corporation. ® indicates a trademark registered in the USA. TM indicates a common law trademark. Filtration.Separation.Solution. is a service mark of Pall Corporation. ◆DELABIE is a trademark of DELABIE; Evita and Infinity are trademarks of Dräger; T-Fill is a trademark of Baxter International; PRESTO is a trademark of PRESTO Group; Puritan Bennet is a trademark of a Covidien company; Quick-Fil is a trademark of AbbVie Inc. 4/16, PDF, GN151028.1GEU 151028.1GEU