Hospital Product Catalogue www.pall.com/medical 1510281.GEU

advertisement
1510281.GEU
www.pall.com/medical
Hospital Product Catalogue
www.pall.com/medical
1
Pall’s Hospital Product Portfolio
This catalogue showcases a selection of products that
Contents
can be used in hospital applications. Pall is committed to
working with our customers to develop robust technologies
Water Filters
3
QPoint™
3
Pall-Aquasafe™
5
Quick Connect Adaptors
7
Accessories - Detachable Shower Rose
9
QPData
10
PCR Technology
11
optimised to perform in their real life environments.
For information on our cord blood and cell therapy
products, visit www.pall.com/medical
Infusion Filters
12
Pharmacy Filtration Devices
14
MIRUS™ System
15
Breathing System Filters
18
Lung Function Diagnostic Filters
20
Minimally Invasive Surgery Filters
21
Medical Gas Filters
22
www.pall.com/medical
2
QPoint™ Water Filter – Tap Assembly
Product description
Order code I Description
Docking Station - Tap Assembly with Quick Connect Inlet
QDTC
Packaging
Membrane area (nominal)
Flow rates (nominal)
1 unit/pkg
Not applicable
Not applicable
Diameter (nominal)
Weight (nominal)
Temperature
88 mm (3.5 in)
84 g (2.96 oz)
Continuous influent temperature 60 °C (140 °F) during
product installation
Maximum influent temperature 75 °C (167 °F) for a total
cumulative period of 90 minutes over the life of each
connected Filter Capsule
5 bar (75 psi) at continuous 60 °C (140 °F) influent
temperature
Reusable
External surfaces may be cleaned using common chrome
compatible sanitising agents.
During routine water system disinfection the Docking
Station with attached Filter Capsule can be left in place
to enable the outlet to be flushed
Polycarbonate/Acrylonitrile Butadiene Styrene (51%), Glass
Filled Nylon (22%), Polyester (20%), Stainless Steel (4%)
Recycled cardboard outer packaging
Maximum operating pressure
Maximum life
Sanitisation
Main materials of construction
Packaging material
Filter Capsule, sterile
QJ212
Jet Outlet, 0.2 μm Filter
QJ22
Jet Outlet, 0.2 μm Filter
12 units/pkg - QJ212 2 units/pkg - QJ22
620 cm2 (96.1 in2)
5.7 L/min at 1 bar
(1.5 gallons/min at 14.5 psi)
13.4 L/min at 3 bar (3.5 gallons/min at 43.5 psi)
18.8 L/min at 5 bar (5.0 gallons/min at 75 psi)
88 mm (3.5 in)
119 g (4.19 oz)
Continuous influent temperature 60 °C (140 °F) during
product installation
Maximum influent temperature 75 °C (167 °F) for a total
cumulative period of 90 minutes over the life of each
connected Filter Capsule
5 bar (75 psi) at continuous 60 °C (140 °F) influent
temperature
62 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
Polyester (84%), Polypropylene (10%),
Polyethersulphone (6%), (Recyclable)
Recycled cardboard outer packaging. Ethylene Vinyl
Acetate (EVA) plastic film blister. Tyvek Polyethylene lid
www.pall.com/medical
3
QPoint Water Filter – Shower Assembly
Product description
Order code I Description
Docking Station – Shower Assembly (QDS)
QDS
Packaging
Membrane area (nominal)
Flow rates (nominal)
1 unit/pkg
Not applicable
Not applicable
Diameter (nominal)
Weight (nominal)
Temperature
88 mm (3.5 in)
145.6 g (5.1 oz)
Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 75 °C (167 °F) for a total
cumulative period of 90 minutes over the life of each
Filter Capsule
5 bar (75 psi) at continuous 60 °C (140 °F) influent
temperature
Reusable
External surfaces may be cleaned using common chrome
compatible sanitising agents.
During routine water system disinfection the Docking
Station with attached Filter Capsule can be left in place
to enable the outlet to be flushed
Acrylonitrile Butadine Styrene (85%), Glass Filled Nylon
(9%), Polyester (2%), Stainless Steel (2%)
Recycled cardboard outer packaging
Maximum operating pressure
Maximum life
Sanitisation
Main materials of construction
Packaging material
Shower Filter Capsule, sterile
QR212
Rose Outlet, 0.2 μm Filter
QR22
Rose Outlet, 0.2 μm Filter
12 units/pkg - QR212 2 units/pkg - QR22
620 cm²
5.7 L/min at 1 bar (1.5 gallons/min at 15 psi)
13.1 L/min at 3 bar (3.5 gallons/min at 44 psi)
18.8 L/min at 5 bar (5.0 gallons/min at 75 psi)
88 mm (3.5 in)
122 g (4.3 oz)
Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 75 °C (167 °F)
for a total cumulative period of 90 minutes over the
life of each Filter Capsule
5 bar (75 psi) at continuous 60 °C (140 °F) influent
temperature
62 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
Polyester (84%), Polypropylene (10%),
Polyethersulphone (6%), (Recyclable)
Recycled cardboard outer packaging. Ethylene Vinyl
Acetate (EVA) plastic film blister. Tyvek Polyethylene lid
www.pall.com/medical
4
Pall-Aquasafe™
Disposable Water Filters
Product description
Order code I Description
Disposable Shower Head Filter for up to 31 day use, sterile
AQF4
AQF42
Packaging
AQF4 (12 units per case)
AQF42 (2 units per case)
1,020 cm2 (158.1 in2)
31.8 L/min at 5 bar (8.4 gallons/min at 75 psi) without
restricted flow connector
15 L/min at 5 bar (3,9 gallons/min at 75 psi) with restricted
flow connector
240 mm (9.45 in)
Membrane area (nominal)
Flow rates (nominal)
Length (excluding quick
connect adaptor - nominal)
Temperature
Maximum upstream
operating pressure
Maximum filter life
Sanitisation
Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter
5 bar (75 psi) at continuous 60 °C (140 °F)
influent temperature
31 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
Disposable Tap Water Filter for up to 31 day use, sterile
AQ31F1S, AQ31F1S2
With smooth outlet
AQ31F1R, AQ31F1R2
With shower rose
AQ31F1S, AQ31F1R (12 units per case)
AQ31F1S2, AQ31F1R2 (2 units per case)
550 cm2 (85.3 in2)
AQ31F1S, AQ31F1S2
17.3 L/min at 5 bar (4.6 gallons/min at 75 psi)
AQ31F1R, AQ31F1R2
17.4 L/min at 5 bar (4.6 gallons/min at 75 psi)
AQ31F1S, AQ31F1S2
72 mm (2.8 in)
AQ31F1R, AQ31F1R2
85 mm (3.4 in)
Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter
5 bar (75 psi) at continuous 60 °C (140 °F)
influent temperature
31 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
www.pall.com/medical
5
Pall-Aquasafe™
Disposable Water Filters (continued)
Product description
Order code I Description
In-Line Disposable Water Filter with Quick Connect Inlet
and Outlet Ports, sterile
AQIN
Packaging
Membrane area (nominal)
Flow rates (nominal)
Length (excluding quick
connect adaptor - nominal)
12 units per case
550 cm2 (85.3 in2)
12.8 L/min at 5 bar (3.4 gallons/min at 75 psi)
70 mm (2.76 in)
Temperature
Continuous influent temperature 60 °C (140 °F)
Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter
5 bar (75 psi) at continuous 60 °C (140 °F)
Maximum upstream
operating pressure
Maximum filter life
Sanitisation
31 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
Disposable Tap Filter for up to 7 day use, sterile
AQ7FSN
With smooth outlet
AQ7FRN
With shower rose
12 units per case
520 cm2 (80.6 in2)
10.8 L/min at 5 bar (2.9 gallons/min at 75 psi)
AQ7FSN
72 mm (2.83 in
AQ7FRN
85 mm (3.35 in)
Continuous influent temperature 50 °C (122 °F)
Maximum influent temperature 70 °C (158 °F) for a total
cumulative period of 30 minutes over the life of the filter
5 bar (75 psi) at continuous 60 °C (140 °F)
7 days
Complementary to water safety plan sanitisation and
hygiene protocols
www.pall.com/medical
6
Quick Connect Adaptors For Water Filters –
Wash Basin, In-Line and Wall Shower Applications
Product description
Order code I Description
– Quick connect adaptor 1/2 in. female thread
TAP1/2FN Without valve
– Quick connect adaptor 1/2 in. female thread
TAP1/2FV With valve
Product description
Order code I Description
– Quick connect adaptor 1/2 in. male thread
TAP1/2MN Without valve
– Quick connect adaptor 1/2 in. male thread
TAP1/2MV With valve
Product description
Order code I Description
– Quick connect adaptor 22 mm female thread
TAP22FN Without valve
– Quick connect adaptor 22 mm female thread
TAP22FV With valve
Product description
Order code I Description
– Quick connect adaptor 24 mm male thread
TAP24MN Without valve
– Quick connect adaptor 24 mm male thread
TAP24MV With valve
Product description
Order code I Description
– Quick connect adaptor 21 mm male thread
TAP21MN Without valve
– Quick connect adaptor 21 mm male thread
TAP21MV With valve
www.pall.com/medical
7
Quick Connect Adaptors For Water Filters –
Wash Basin, In-Line and Wall Shower Applications
Product description
– Wash basin and in-line applications
– Quick connect adaptor 1/2 in. male thread
SST1/2MN Stainless steel connector without valve,
suitable for DI water
– Wash basin and in-line applications
– Quick connect adaptor 1/2 in. female thread
SST1/2FV Stainless steel connector with valve,
suitable for DI water
Product description
– Wash basin and in-line applications
– Quick connect adaptor 16 mm female thread
Order code I Description
CVK16N Without valve
– Wash basin
– Only for temporary use e.g. until a threaded outlet
can be installed
TAPUC Universal connector (15-29 mm)
Product description
Order code I Description
– Rotating adaptor for fixed wall shower
FR2521-M24-12-ROT Rotating adaptor for PRESTO
DL400 fixed wall shower
– Fixed adaptor for fixed wall shower
FR2521-M24-12-FIXE Fixed adaptor for PRESTO PL30
fixed wall shower
Product description
Order code I Description
– Fixed adaptor for jet fixed wall shower
FR2520-M24-TJ Fixed adaptor for DELABIE jet fixed
wall shower
Order code I Description
www.pall.com/medical
8
Quick Connect Adaptors For Water Filters –
Flexible Hose Shower Applications
Product description
Order code I Description
– Quick connect adaptor 1/2 in. male thread
SHO1/2MNN Without valve, without restrictor
– Quick connect adaptor 1/2 in. male thread
SHO1/2MVN With valve, without restrictor
Product description
Order code I Description
– Quick connect adaptor 1/2 in. male thread
SHO1/2MNR Without valve, with restrictor
– Quick connect adaptor 1/2 in. male thread
SHO1/2MVR With valve, with restrictor
Accessories
Product name
Product description
Order code I Description
Packaging
Maximum filter life
Maximum continuous
influent water temperature
Maximum upstream
operating pressure
Pall-Aquasafe™ Detachable Shower Rose
Specifically designed as an attachment to the Pall-Aquasafe
Water Filter (AQ7FSN, AQ14F1S or AQ31F1S), sterile
AQFROSE
25 units per case
Single use following attachment to the AQ7FSN, AQ14F1S
or AQ31F1S filter
40 ºC (104 ºF)
5 bar (75 psi) at continuous 40 °C (104 °F) influent
temperature
Product description
Order code I Description
– Miscellaneous shower positioning applications
E135 Elbow connection, 1/2 in., 60°
Product description
Order code I Description
– Miscellaneous sampling applications
PN22C Connector for ease of water sampling
www.pall.com/medical
9
QPData
Product description
Order code I Description
Custom software data management tool for water filter traceability
QPData Full Service and Support Mode (Annual Fee)
QPDATA1
QPData Pre-loaded and Configured Smartphone
QPDATA2
QPData Paired and Compatible Scanner
QPDATA3
QPData Customer Smartphone Configuration
QPDATA4
Please note:
Data SIM card and/or contract is not included. The warranty of any hardware supplied by Microsec
and/or Pall is limited to the Manufacturer’s warranty.
Water Testing
Particle Analysis in Water Distribution Systems
Water distribution systems, particularly in older or large buildings may contain high levels of organic and inorganic material in the form of particles (such as,
sand, silicates, rust) and colloids. Those water contaminants may contribute to biofilm formation or be derived from already established biofilm within the
system. The particulate load in the water may visibly change the water colour. The turbidity of the water represents an indicator of the particulate/colloidal
concentration in the system.
Particulate and colloidal load in water distribution systems can be analyzed using the Silt Density Index test (SDI). Pall Medical offers SDI testing in your facilities
by our specialists. Based on review of the SDI report, system specific and cost effective prefiltration technologies can be selected from a large Pall pre-filter
portfolio in order to deliver maximum benefits for your water distribution system. Please contact your local Pall representative in order to find out if an SDI test
can be performed in your facility.
Please note: Flow reduction or blockage of POU sterilizing grade filters before their intended lifetime may indicate a high particulate
load in the water distribution system.
Filter Replacement
Pall Medical offers a service to exchange Pall point-of-use filters and large-scale prefilter cartridges in your facility.
Due to the use of quick connect adaptors, point-of-use filter exchange can be performed easily within seconds by trained cleaning or facilities maintenance
staff, nursing staff, or other trained persons. However, if desired and where possible, Pall Medical offers the option to exchange filters in your facility. This can
be performed using professional external technical service and cleaning companies in your area.
The exchange of Pall large-scale prefilter cartridges in cooperation with the technician in your facility may also be available.
Please contact your local Pall sales office in order to obtain more information about the availability of filter
exchange services in your area.
Turnkey Program
In some locations, Pall Medical offers a Turnkey Program that includes particulate water testing, microbial water analysis, filter replacement and
additional services.
Please contact your local sales office in order to obtain detailed information about this program and availability
of this service in your area.
www.pall.com/medical
10
PCR Technology
Product name
Product description
Ordering information
Technical data
Pall GeneDisc® System
Real time Legionella risk management using the latest PCR technology – Quantified results within 2-3 hours, all
inclusive product from sample to result, closed real-time PCR with minimised operator intervention, user-friendly software
with direct display of results, simultaneous read out of Legionella spp. and L. pneumophila, seamless data transfer.
Reorder code
Description
Sample Number Packaging
EGDCV3A
GeneDisc Cycler Base-Unit
Single unit
EGDSV3A
GeneDisc Cycler Sub-Unit
Single unit
EGDUL1A120
GeneDisc Ultra-Lyser (US Power Supply)
Single unit
EGDUL1A230
GeneDisc Ultra-Lyser (EU Power Supply)
Single unit
EGDUP1A
GeneDisc Ultra-Purifier
Single unit
PENVI1096
Extraction Pack Environment 1 – All water samples
96
96 units
PENVI3100
Extraction Pack Environment 3 – Clear water samples
100
100 units
ALEGPNE105
Standard Calibrated DNA Legionella pneumophila
5 units
GLEGPNE106006
GeneDisc Pack – Legionella pneumophila Detection
30
6 plates
and Quantification
GLEGPNE112006
GeneDisc Pack – Legionella pneumophila Detection
66
6 plates
and Quantification
GLEGSPP106006
GeneDisc Pack – Legionella spp. Detection and Quantification 30
6 plates
GLEGDUO106006
GeneDisc Pack - Legionella spp. and Legionella pneumophila
30
6 plates
Detection and Quantification
GLEGOID112006
GeneDisc Pack - Legionella spp. and Legionella pneumophila
72
6 plates
Identification
Total turnaround time <3 hours
PCR cycle time
<1 hour
For information on the analytical discs, please contact your local sales office or visit www.pall.com
www.pall.com/medical
11
Infusion Filters
Product name
Product description
Order code I Description
Packaging
Volume
Membrane
Filter and tubing
Special features
Maximum filter life
Information for use
Pall Nanodyne™ ELD Filter
Infusion filter with endotoxin-retentive
Posidyne membrane
ELD96LLCE
0.9 mm ID microbore tubing,
slide clamp, luer connectors
ELD96LYLE
0.9 mm ID microbore tubing,
slide clamp, luer connectors,
Y-injection site
ELD96NTE
Luer connectors, without tubing
40 units per case (ELD96NTE)
50 units per case (ELD96LLCE,
ELD96LYLE)
2 mL plus tubing volume
Pall Nanodyne NEO Filter
Infusion filter with endotoxin-retentive
Posidyne membrane and small volume
NEO96E
0.5 mm ID ultra-microbore tubing,
slide clamp, luer connectors
NEO96NYE
0.5 mm ID ultra-microbore tubing,
slide clamp, luer connectors
Y-piece for needleless connection
Pall Supor™ AEF Filter
Infusion filter with low-protein-binding
Supor membrane
AEF1E
0.9 mm ID microbore tubing,
slide clamp, luer connectors
AEF1NTE
Luer connectors, without tubing
50 units per case
50 units per case
0.4 mL
0.2 µm Posidyne membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
96 h
Single patient use
0.2 µm Posidyne membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
96 h
Single patient use
AEF1E
1.0 mL
AEF1NTE
0.7 mL
0.2 µm Supor membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
24 h
Single patient use
www.pall.com/medical
12
Infusion Filters (continued)
Product name
Product description
Pall Lipipor™ TNA Filter
Filter for lipid-containing solutions for
parenteral nutrition
Order code I Description
TNA1E
0.9 mm ID microbore tubing,
luer connectors
Pall Lipipor TNA Filter
Filter for lipid-containing solutions for
parenteral nutrition – allows for
infusion under gravity
TNA2E
3.0 mm ID standard bore tubing,
slide clamp, luer connectors
Packaging
Volume
50 units per case
2.3 mL
50 units per case
12 mL
Membrane
Filter and tubing
1.2 µm Polyamide membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
24 h
Single patient use
1.2 µm Supor membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
24 h
Single patient use
Special features
Maximum filter life
Information for use
Pall Lipipor NEO and Lipipor NLF Filters
Infusion filters for lipid-containing
solutions for parenteral nutrition in
paediatric and neonatal patients
NLF1E
0.9 mm ID microbore tubing,
small volume, slide clamp,
luer connnectors
NLF2E
0.9 mm ID microbore tubing,
slide clamp, luer connectors
NLF1X
22.5 cm long upstream tubing,
25 cm long downstream tubing ,
slide clamp, luer connectors
50 units per case
NLF1E
0.5 mL
NLF2E
0.8 mL
NLF1X
1.1 mL
1.2 µm Supor membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
24 h
Single patient use
www.pall.com/medical
13
Pharmacy Filtration Devices
Product name
Product description
Order code I Description
Packaging
Membrane | Pore size
Housing
Housing diameter
Connectors
Membrane area
Volume
Free of latex
Pall PharmAssure® Syringe Filter
Syringe filter for drug preparation and intravenous, epidural
and subcutaneous syringe bolus drug administration
– Low protein binding
– Extensive drug compatibility
25 mm (HP1002, HP1012, HP1050)
32 mm (HP4642, HP4644, HP4640)
50 units per case
HP1002, HP4642
0.2 µm Supor membrane
HP4644
0.45 µm Supor membrane
HP1012
1.2 µm Supor membrane
HP1050, HP4640
5.0 µm Supor membrane
Acrylic
25 mm (HP1002, HP1012, HP1050)
32 mm (HP4642, HP4644, HP4640)
Luer connectors (m/f)
2.8 cm2 (HP1002, HP1012, HP1050)
5.3 cm2 (HP4642, HP4644, HP4640)
<0.85 mL (HP1002, HP1012, HP1050)
<1.0 mL (HP4642, HP4644, HP4640)
Yes
Pall PharmAssure 25 mm Hydrophobic Vent Filter
Vent filter for sterile venting of sterile drug containers
HP2002
50 units per case
0.2 µm hydrophobic acrylic copolymer
Acrylic
25 mm
Luer connectors (m/f)
2.8 cm2
n/a
Yes
www.pall.com/medical
14
MIRUS™ System
Product name
Product description
MIRUS™ Controller
The MIRUS Controller (MC) delivers gaseous volatile
anaesthetic agent via an interface line to the MIRUS
Exchanger (micro re-breather) where the volatile anaesthetic
agent is mixed with the inspiratory gas and delivered to the
patient. It constantly measures the agent concentration and
automatically maintains the target MAC.
MIRUS Bottle Adaptor
MIRUS Bottle Adaptor is a volatile anaesthetic agent
specific key adaptor to the corresponding liquid volatile
anaesthetic agent bottle and is used to fill the liquid
volatile anaesthetic agent into the MIRUS Controller
Order code I Description
MC-M-ISO
MIRUS Controller for Isoflurane
MC-M-SEV
MIRUS Controller for Sevoflurane
MC-M-DES
MIRUS Controller for Desflurane
Packaging
Includes
1 unit per case
– 1 MIRUS Controller (Software included)
– 1 Country specific power cable
– 1 Quick guide
– 1 Instructions for use
– 1 Bottle Adaptor (according to gas)
–
BA-ISO-K
MIRUS Bottle Adapter Isoflurane
BA-DES-S
MIRUS Bottle Adapter Desflurane
BA-SEV-K
MIRUS Bottle Adapter Sevoflurane in Safe-T-Fill◆ bottles
BA-SEV-Q
MIRUS Bottle Adapter Sevoflurane in Quik-Fil◆ bottles
1 unit per case
–
Spare parts (MC power cable)
Additional parts
(Quick Guide – Print)
(Instructions for Use – CD)
–
MC-01-001
MC Power Cable Germany
MC-01-002
MC Power Cable UK
MC-01-003
MC Power Cable France
MC-01-004
MC Power Cable Italy
MC-01-005
MC Power Cable Switzerland
MC-01-006
MC Power Cable Austria
MC-QG-UK
MIRUS Quick Guide (Print) – English
MC-QG-FR
MIRUS Quick Guide (Print) – French
MC-QG-DE
MIRUS Quick Guide (Print) – German
MC-QG-IT
MIRUS Quick Guide (Print) – Italian
MC-IFU-CD-EIFU
MIRUS Controller instruction for use (on CD)
www.pall.com/medical
15
MIRUS System (continued)
Product name
Product description
MIRUS Draining Kit
Draining Kits are used to drain residual volatile anaesthetic
agent from the MIRUS Controller.
Clean Air
Clean Air is an open reservoir scavenger system (ORS) for
the evacuation of residual volatile anaesthetic gas in the
expiration volume of the ventilator via the available ICU
vacuum system.
It has a country specific connection to the vacuum system
and a specific connection to the ventilator.
Order code I Description
MC-01-13
MIRUS Draining Kit for Isoflurane
Packaging
Includes
1 unit per case
– Draining bottle
– Bottle cap
– Draining tube with bottle cap and clamp
– Allen key
– Instruction for use
MC-01-13-1
MIRUS Draining Kit - spare bottle
–
ORS-01
Clean Air (ORS)
ORS-02
Clean Air (ORS) Servo edition CA-02
Vaccum Connection
ORS-01-DE
Clean Air vacuum connection Germany
ORS-01-UK
Clean Air vacuum connection UK
ORS-01-FR
Clean Air vacuum connection France
Ventilator Adapter
ORS-VC-02
Clean Air vent. connection GE Engström Carestation
ORS-VC-04
Clean Air vent. connection Dräger Evita◆ 2/4/XL Ventilator
ORS-VC-05
Clean Air vent. connection Dräger Evita Infinity◆ V500
Ventilator
ORS-VC-06
Clean Air vent. connection Puritan Bennett◆ 840
Ventilator
ORS-VC-08
Clean Air vent. connection Servo-i/u
1 unit per case
–
Spare parts (Draining kit)
Additional parts
(Instructions for Use)
–
ORS-01-IFU-DE
Clean Air Step-by-Step IFU DE
ORS-01-IFU-UK
Clean Air Step-by-Step IFU UK
ORS-01-IFU-FR
Clean Air Step-by-Step IFU FR
ORS-01-IFU-IT
Clean Air Step-by-Step IFU IT
www.pall.com/medical
16
MIRUS System (continued)
Product name
Product description
MIRUS Filter
Breathing system filter, designed to be used in connection
with a MIRUS Reflector or for use as a “stand alone”
filter in anaesthesia
MIRUS Reflector
Volatile anaesthetic gas rebreathing system, to be used in
conjunction with a MIRUS Filter and a MIRUS Controller.
Including an interface line to connect to the MIRUS Controller
Order code I Description
MF1
MIRUS Filter
MF1D
MIRUS Filter
MF1 - 50 units/ case
MF1D - 5 units/ case
Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres
50 mL
100%
MR1
MIRUS Reflector
>99.999%
–
>99.99%
–
<2.5 cm H2O
Patient end 15 mm female / 22 mm male
Machine end 22 mm female
Female luer
approx. 50 g
Max 48h single patient use
Yes
<5 cm H2O
Machine end 22 mm female
Packaging
Filter media
Filter volume
Filtration efficiency for liquid
borne bacteria/viruses
Filtration efficiency for
airborne bacteria
Filtration efficiency for
airborne viruses
Resistance @ 60 L/min
Filter ISO connectors
ISO monitoring port
Product dry weight
Recommended use
Free of latex
3 units per case
Shipper box: 4 cases
Carbon media to reflect volatile anaesthetic agents
50 mL
–
–
approx. 210 g
Max. 7 day multiple patient use
Yes
www.pall.com/medical
17
Breathing System Filters
Product name
Product description
Pall Ultipor™ 25 Breathing System Filter
Breathing system filter for anaesthesia – also suitable for
low tidal volumes
Order code I Description
BB25
With monitoring port
BB25G
With monitoring port (bulk pack)
BB25S
With monitoring port, sterile
BB25GS
With monitoring port, sterile
(bulk pack)
BB25F
With monitoring port, flex tube
and flex tube cap
BB25FG
With monitoring port, flex tube
and flex tube cap (bulk pack)
BB25FS
With monitoring port, flex tube
and flex tube cap, sterile
BB25FU
With monitoring port and flex tube
Packaging
50 units per case (BB25, BB25S, BB25F, BB25FS, BB25FU,
BB2000AP, BB25D, BB25N)
200 units per case (BB25DG, BB25DFG)
250 units per case (BB25G, BB25FG, BB25NG)
300 units per case (BB25GS)
Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres
Bulk pack
Filter media
BB2000AP
With monitoring port, expandable
catheter mount (with two straight
connectors) and catheter mount cap
BB25D
With monitoring port, flex tube
and fixed non-ported elbow
BB25DG
With monitoring port, flex tube
and fixed non-ported elbow
(bulk pack)
BB25DFG
With monitoring port and flex tube
bonded to a fixed, non-ported elbow
BB25N
With monitoring port and fixed,
non-ported elbow
BB25NG
With monitoring port and fixed,
non-ported elbow (bulk pack)
Pall Ultipor 100 Breathing System Filter
Breathing system filter for anaesthesia and
intensive care ventilation
BB100E
BB100ES
Sterile
BB100EF
With flex tube and flex tube cap
BB100EFS
With flex tube and flex tube cap, sterile
BB100P
With monitoring port
BB100PS
With monitoring port, sterile
BB100PF
With monitoring port, flex tube and flex tube cap
BB100PFS
With monitoring port, flex tube and flex tube cap, sterile
50 units per case
–
35 mL
100%
Composite media comprised, on the patient side, of a
hydrophobic layer manufactured using silicone resin
bonded man-made mineral fibres and, on the machine
side, an integral hydrophilic cellulose layer
85 mL
100%
>99.999%
≥99.999%
Weight
Recommended use
Approx. 1.5 cm H2O
Approx. 3.5 cm H2O
Patient end 15 mm female / 22 mm male
Machine end 22 mm female / 15 mm male
26 g
Patient end use only, max. 24 h, single patient use
Free of latex
Yes
Approx. 1 cm H2O
Approx. 2 cm H2O
Patient end 15 mm female / 22 mm male
Machine end 22 mm female
47 g
Patient end use only, max 24 h if nebulisation is used, use may
be extended to a maximum of 48 hours when nebulisation is not
used, single patient use
Yes
Filter volume
Filtration efficiency for
liquidborne bacteria/viruses
Filtration efficiency for
airborne bacteria/viruses
Resistance @ 30 L/min
Resistance @ 60 L/min
Filter ISO connectors
www.pall.com/medical
18
Breathing System Filters (continued)
Product name
Product description
Pall BB50T Breathing System and Gas Line Filters
Machine end breathing system and gas line filters
Order code I Description
BB50TE
Machine end applications in breathing systems and
gas line applications
BB50TES
For machine end applications in breathing systems and
gas line applications (e.g., insufflation), sterile
50 units per case (BB50TE, BB50TES)
Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres
Approx. 90 mL
100%
Packaging
Filter media
Filter volume
Filtration efficiency for
liquidborne bacteria/viruses
Filtration efficiency for
airborne bacteria/viruses
Resistance @ 30 L/min
Resistance @ 60 L/min
Filter ISO connectors
Weight
Recommended use
Free of latex
>99.999%
Approx. 1 cm H2O
Approx. 2 cm H2O
Patient end 22 mm male
Machine end 22 mm female
39 g
BB50TE, BB50TES: Max. 24 h – in connection with a
high-efficiency HME (heat and moisture exchanger)
extended use may be permitted
Yes
www.pall.com/medical
19
Lung Function Diagnostic Filters
Product name
Product description
Order code I Description
Packaging
Bulk pack
Filter media
Filter volume
Cross contamination
reduction efficiency
Resistance @ 12 L/sec
Connectors
Weight
Recommended use
Free of latex
Pall Pro-Tec® Filter for Pulmonary Function Testing
Filter for lung function diagnostics
PF30S
30 mm female connector
PF30SG
30 mm female connector (bulk pack)
PF30SJE
Modified 30 mm female connector
PF30SJG
Modified 30 mm female connector (bulk pack)
25 units per case
250 units per case
Polypropylene
Approx. 40 mL
99.9999%
Pall Pro-Tec Filter Kit for Pulmonary Function Testing
Filter kit for lung function diagnostics
PF30KIT1
PF30S including mouthpiece and nose clip
PF30KIT2
PF30SJE including hard plastic mouthpiece
PF30KIT3
PF30SJE including mouthpiece and nose clip
0.6 cm H2O
30 mm female or 30 mm modified female depending
upon variant
26 g
Single patient use
Yes
0.6 cm H2O
30 mm female or 30 mm modified female depending
upon variant
26 g
Single patient use
Yes
25 units per case
Polypropylene
Approx. 40 mL
99.9999%
www.pall.com/medical
20
Minimally Invasive Surgery Filters
Product name
Pall Insufflator Gas Line Filter
Product description
Filter set for insufflation gases
Order code I Description
IGF1
7.5 cm silicone tubing and luer
connector inlet (f),
52.5 cm silicone tubing and luer
connector outlet (m), sterile double
peel-pouch
IGF1E
7.5 cm PVC tubing and luer connector
inlet (f), 52.5 cm PVC tubing and
luer connector outlet (m), sterile
double peel-pouch
IGF1L
7.5 cm PVC tubing and luer connector
inlet (f), 250 cm PVC tubing and luer
connector outlet (m), sterile double
peel-pouch
IGF1M
7.5 cm PVC tubing and luer connector
inlet (m), 250 cm PVC tubing and
luer connector outlet (f), sterile
single peel-pouch
IGF1C
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
single peel-pouch
IGF1CD
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
double peel-pouch
IGF1R
7.5 cm PVC tubing and 15 mm (m)
connector at machine end and
250 cm long tubing and revolving (m)
connector, sterile single peel-pouch
20 units per case
Hydrophobic media manufactured
using silicone resin bonded man-made
mineral fibres
Packaging
Filter media
Housing
Tubing
Bacteria filtration efficiency
(airborne)
Viral filtration efficiency for
viruses (airborne)
Acrylic
PVC or silicone depending upon
variant
>99.999%
>99.99%
High flow insufflation set with high
efficiency hydrophobic Pall gas filter
Insufflator filter set for high flow
applications
FRIGF2
3 m PVC tubing, sterile double
peel-pouch
Pall LaparoShield® Laparoscopic
Smoke Filtration System
Filtration system for smoke generated
during laparoscopic surgery
LSF1
Approximately 45 cm PVC tubing
and clamp, male luer connector
with rotating collar, sterile double
peel-pouch
LSF2
Male luer connector with rotating
collar, sterile double peel-pouch
20 units per case
PTFE
Acrylic
PVC
10 units per case
Pre-filtration layers - glass fibre,
polyester, acrylic; Membrane layers polytetrafluoroethylene (PTFE).
Chemical absorbant layers - activated
carbon; Film layers - ethylene vinyl
acetate (EVA)
Polyester
PVC, EVA
>99.9999% with test organism
Brevundimonas diminuta
>99.999% with test organism
Bacteriophage MS-2
>99.999% with test organism
Brevundimonas diminuta
>99.999% with test organism
Bacteriophage MS-2
www.pall.com/medical
21
Medical Gas Filters
Product name
Product description
Order code I Description
Packaging
Filter membrane
Housing
Tubing
Bacteria filtration efficiency
Viral filtration efficiency for
viruses
Pall Oxygenator Gas Line Filter
Bacteria, viral and particulate removal filter for
medical gases
ORO1H
1/4 in. – tubing connections
40 units per case
Hydrophobic media manufactured using silicone resin
bonded man-made mineral fibres
Acrylic
n/a
>99.999% (airborne)
>99.99% (airborne)
Pall Gas Line Filter
Bacteria, viral and particulate removal filter for
medical gases
BRO9T
3/16 in. – tubing connection, 7.5 cm silicone tubing
100 units per case
Acrylic co-polymer/Nylon, hydrophobic
Silicone
Yes
100% (liquidborne)
100% (liquidborne)
www.pall.com/medical
22
Visit us on the Web at www.pall.com/medical
Pall European Headquarters
Avenue de Tivoli 3
1700 Fribourg
Switzerland
+41 (0)26 350 53 00 phone
LifeSciences.EU@pall.com e-mail
Pall Asia-Pacific Headquarters
1 Science Park Road, #05-09/15
East Wing, The Capricorn
Singapore Science Park II, Singapore 117528
+65 6388 8688 phone
sgcustomerservice@pall.com e-mail
International Offices
Pall Corporation has offices and plants throughout the world in locations such as: Argentina, Australia, Austria, Belgium,
Brazil, Canada, China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands,
New Zealand, Norway, Poland, Puerto Rico, Russia, Singapore, Spain, Sweden, Switzerland, Taiwan, Thailand, the
United Kingdom, the United States, and Venezuela. Distributors in all major industrial areas of the world. To locate the
Pall office or distributor nearest you, visit www.pall.com/contact
This document is not for distribution in the USA.
The information provided in this literature was reviewed for accuracy at the time of publication. Product data may
be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly.
Part numbers quoted are protected by the Copyright of Pall Europe Ltd.
© 2016, Pall Corporation. Pall,
, GeneDisc, Kleenpak, LaparoShield, Lipipor, Marksman, Nanodyne, Pall-Aquasafe,
PharmAssure, Poly-Fine, Posidyne, Pro-Tec, QPoint, Starclear, Supor, and Ultipor are trademarks of Pall Corporation.
® indicates a trademark registered in the USA. TM indicates a common law trademark. Filtration.Separation.Solution.
is a service mark of Pall Corporation. ◆DELABIE is a trademark of DELABIE; Evita and Infinity are trademarks of Dräger;
T-Fill is a trademark of Baxter International; PRESTO is a trademark of PRESTO Group; Puritan Bennet is a trademark of a
Covidien company; Quick-Fil is a trademark of AbbVie Inc.
4/16, PDF, GN151028.1GEU
151028.1GEU
Download