OUTLINE TDI SINGLE ENCLOSURE 4.44 12.62 REF

advertisement
OUTLINE
4.44
REF
12.62 REF
11.12
REF
3.97
REF
LOCATION APPROX. AS SHOWN
15
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
ASCO REF:
TDI_SINGLE_ENCL.ASM
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
C
257962
ER NO.
-
-
-
-
11/15
CH JH
BOM UPDATE
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 1 OF7
SHT 1 OF 8
DISPLAY ASSY (PART OF ITEM 1)
IS ASSEMBLED AFTER ASSY OF
ITEM 1 (MAIN) TO ITEM 4.
ASSEMBLE / SECURE
TO ITEM 5
1
(MAIN)
4
9
REF: #8 GROUNDING NUT
5
12
END CAPS NEED TO BE REMOVED
TO GET ACCESS TO ITEM 2 MOUNTING
SCREWS. AFTER ITEM 2 IS SCREWED
INTO PLACE, END CAPS ARE TO BE
SLID BACK IN PLACE.
10
11
4 PLACES FOR
MOUNTING ITEM 1
12
6
10
7
8
9
ASSEMBLE / SECURE
TO ITEM 5
REF: #8 GROUNDING NUT
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 2 OF7
SHT 2 OF 8
DETAIL A
+ + - -
POWER SUPPLY
(1052606)
TDI
(TB201)
13
INPUT VOLTAGE RANGE
90-264 VAC / 120-375 VDC
L
1 2 3 4 5 6
N
WIRING DIAGRAM
USE LENGTH AS NEEDED
DETAIL A
INTERNAL WIRING
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 3 OF7
SHT 3 OF 8
DC POWER
24 VDC / 36 W
POWER SUPPLY
ETHERNET P1
ETHERNET P2
NOTE:
FOR ETHERNET CABLES,
USE CAT5e OR BETTER
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 4 OF7
SHT 4 OF 8
MOUNTING PLATE
REFERENCE VIEW
VERTICAL OPEN MOUNTING
FOR EXTERNAL WIRING
LOCATION APPROX. AS SHOWN 14
MOUNTING PLATE TABS
REF: ENCLOSURE / WALL
ENCLOSURE SHOWN OPEN
AND HUNG ON MOUNTING
PLATE TABS.
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 5 OF7
SHT 5 OF 8
.30 REF
ENCLOSURE / WALL MOUNTING OPTIONS
DETAIL B
TYP 12 PLACES
.71
SEE DETAIL B
.50 REF
2.71
3.40
12.41
11.00
7.00
5.50
12.41
6.21
2.75
2.75
SEE DETAIL A
REF #8-32
GROUNDING
STUD
REF #8-32
GROUNDING
STUD
6.96
5.50
8.00
7.00
1.69
10.91
3.37
1.46 1.96
8.00 10.91
1.64
3.28
1.24
2.47
.187 REF
12 PLACES
.91
1.81
1.24
2.47
1.69
3.37
REF: ENCLOSURE MOUNTING OPTIONS
REF: WALL / ELECTRICAL BOX MOUNTING
SEE SHEET 6 FOR SUGESTED WALL ASSEMBLY
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 6 OF7
SHT 6 OF 8
SUGGESTED WALL ASSEMBLY
1.47 X 3.40 (2 X 4) WALL STUD, REF
2 GANG ELECTRICAL BOX
REFERENCE TYPE A238
3-31/32" REF
WALL HOLE
REF: 1/4" LAG SCREWS
AND 1/4" WASHERS
3-15/16" REF
WALL HOLE
-
PROJECT NAME:TDI
TDI SINGLE ENCLOSURE
THIRD ANGLE
PROJECTION
BY
DRAWN BY
CHECKED
CH
DATE
Pro/Engineer
01/15
MANUFACTURING TOLERANCES TO
BE IN ACCORDANCE WITH ASCO
PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
JH
09/15
JH
09/15
-
-
DRAFTING
APPROVAL
FINAL
APPROVAL
R
DRAFT
0.167
-
:1
SCALE
ASSEM. REF. NO.
PROPERTY OF ASCO POWER TECHNOLOGIES. USE PERMITTED FOR OUR
WORK ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL
OF ASCO POWER TECHNOLOGIES
ASCO
®
ASCO POWER TECHNOLOGIES,
L.P.
FLORHAM PARK, NEW JERSEY 07932 U.S.A.
ER NO.
----------
-
-
-
-
-
-
BY
APP.
DATE
AE
AN
AM
AJ
AL
CH
AV
AA
PS
AR
AG
AP
AC
AS
LM
SIZE
CS 1052187
CHANGE
LETTER
C
ECN
NO.
257962
SHEET 7 OF7
SHT 7 OF 8
change letter C
ECN 257962
1052187
TOUCH DISPLAY INTERFACE (TDI) SINGLE ENCLOSURE
Item
#
1
1
TDI final assembly, standard
Description
Manufacturer
Manufacturer Part Number
ASCO Part # Ref File Notes
4
1
enclosure, top
5
1
enclosure, bottom
6
1
power supply, 24V, 30W
621859-004
7
1
Rail, 35mm DIN, 2.75"L
383774-006
8
1
hole plug, 0.875"D, black, nylon
988000-001
2
3
1045773
1045775
416520
9
4 screw, #6-32 x 3/8"L, steel, black, SEMS
10
4
nut, #6-32, SS, KEPS
11
4
washer, flat, #6, SS
076183-001-A1
12
2
nut, #8, hex, SS
073412-012-C1
095598-005-8
13
-
wire, 18 AWG, white
14
1
Label, Danger Hazardous
15
1
Nameplate, ID, Label
607567-003-A11
285002-006
1
711843
609056-004
NOTES:
1. Quantity as required.
ASCO Power Technologies, L.P.
Florham Park, NJ 07932
Property of ASCO Power Technologies, L.P. Use permitted for our work only. All rights of design and invention are reserved.
sheet 8 of
8
Download