REVISIONS PUBLIC SAFETY BUILDING PROJECT DESCRIPTION: TENANT IMPROVEMENT PROJECT AT UCCS FOR THE MILITARY AND STUDENT VETERAN CENTER REMODEL. THE SCOPE OF THE REMODEL COVERS A RECEPTION AREA, BENEFITS PROCESSING OFFICES, STUDENT LOUNGE WITH SELF-SERVICE COFFEE BAR, SMALL GROUP MEETING AREAS, AND STUDENT COMPUTER STATIONS. EXISTING BUILDING CODE INFORMATION: ORIGINAL CONSTRUCTION DATE: 2003 CONSTRUCTION TYPE: V-N SPRINKLERED: NO OCCUPANCY TYPE(S): B - BUSINESS, AND S-4 - PARKING FIRE RESISTIVE REQUIREMENTS: 4 HOUR OCCUPANCY SEPARATION EGRESS REQUIREMENTS: 2 EXITS EXISTING TENANT SPACE INFORMATION: AREA: 2,318 SF TOTAL (2,168 SF @ B OCC., THE REST IS ACCESSORY SPACE) OCCUPANCY: B - BUSINESS OCCUPANCY LOAD: 22 OCCUPANTS EXISTING PLUMBING FIXTURE COUNT: 6 FIRE RESISTIVE REQUIREMENTS: N/A EGRESS WIDTH: 36" AISLE / 60" CORRIDOR (EXIST. TO REMAIN) CHANGE OF OCCUPANT LOAD AT TENANT SPACE INFORMATION: 1. MEANS OF EGRESS IBC 1003 EXISTING (FIRST LEVEL) OCCUPANT LOAD: 5100 / 100= 51 OCCUPANTS (2 EXITS) DATE PROJECT TEAM MECHANICAL & PLUMBING ENGINEER: OWNER / TENANT: UCCS - Veteran Affairs 1420 Austin Bluffs Pkwy Colorado Springs, CO 80918 Phone: 719-255-3073 Mariness Falcon Leffingwell Consulting Engineers, Inc. 1315 North El Paso Street Colorado Springs, CO 80903 Phone: 719-473-5998 Gary Leffingwell ARCHITECT: ELECTRICAL ENGINEER: Tremmel Design Group 201 E. Las Animas Street, Suite 113 Colorado Springs, CO 80903 Phone: 719-623-5641 Mark Tremmel Sharon Allen Elizabeth Olney Chavez Tiffany & Ayers 119 W Cucharras St Colorado Springs, CO 80903 Phone: 719-636-0021 Josh Ayers Errick Reynolds 01.29.16 INTERIOR DESIGN: Senger Design Group 523 S. Cascade Avenue, Suite B Colorado Springs, CO 80903 Phone: 719-522-1520 Cindy Senger Beth Vincent REVISED (FIRST LEVEL) OCCUPANT LOAD: EXISTING BLDG. TO REMAIN = 23 PERSONS OCCUPANT LOAD CHANGE = 58 PERSONS (SEE CALC. BELOW) AREA OF OCCUPANT LOAD CHANGE (OFFICES, LOUNGE, RECEPTION, AND MEETING SPACES): OCCUPANCY: B & A OCCUPANCY LOAD: OFFICES: LOUNGE: MEETING ROOMS & STUDY: RECEPTION DESK: SEATED WAITING: TOTAL OCCUPANTS OF CORRIDOR EXIT= 623 / 100= 591 / 15= 441 / 100= 126 / 100= 47 / 15= TOTAL: 1/2 PER EXIT= 7 PERSONS 40 PERSONS 5 PERSONS 2 PERSONS 4 PERSONS 58 PERSONS 29 PERSONS 29 PERSONS ENTRY CANOPY CORRIDOR EXIT CAN HOLD UP TO 30 PERSONS (MORE THAN 30 OCCUPANTS REQUIRES THE CORRIDOR TO BE RETROACTIVELY FIRE RATED) PLUMBING FIXTURE COUNT PROVIDED: FIRE RESISTIVE REQUIREMENTS: N/A EXISTING CORRIDOR EGRESS WIDTH: 5'-0" 6 MAX. PATH OF TRAVEL FOR SINGLE EXIT: ACTUAL PATH OF TRAVEL: 98 FT 100 FT FOR 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) Military and Student Veteran Center Remodel PROJECT DATA & CODE REVIEW APPLICABLE CODES 2011 PIKES PEAK REGIONAL BUILDING CODE 2009 INTERNATIONAL BUILDING CODE W/ AMENDMENTS 2009 INTERNATIONAL EXISTING BUILDING CODE W/ AMENDMENTS 2009 INTERNATIONAL ENERGY CONSERVATION CODE W/ AMENDMENTS 2009 INTERNATIONAL MECHANICAL CODE W/ AMENDMENTS 2009 INTERNATIONAL FUEL GAS CODE 2009 INTERNATIONAL PLUMBING CODE 2011 NATIONAL ELECTRICAL CODE / NFPA-70 W/ AMENDMENTS 2009 INTERNATIONAL FIRE CODE NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS NFPA 14 INSTALLATION OF STANDPIPE, PRIVATE NFPA 72 NATIONAL FIRE ALARM CODE NFPA 20 INSTALLATION OF FIRE PUMPS 2009 ICC/ANSI A117.1 ACCESSIBILITY STANDARD 2004 ASME A17.1 SAFETY CODE FOR ELEVATORS AND ESCALATORS 2002 ASME A17.3 SAFETY CODE FOR EXISTING ELEVATORS AND ESCALATORS 2011 FLOODPLAIN REGULATION AMENDMENTS 2.0 FIRE PROTECTION SYSTEMS (IBC CH. 4) A. OCCUPANT LOAD PER LOAD CHANGE INFORMATION (SEE ABOVE) B. EXISTING CORRIDOR WIDTH = 60 INCHES (IBC 1005.1) C. MAXIMUM ALLOWABLE DEAD END CORRIDOR = 20 FEET (IBC 1016.3) 4.0 OTHER LIFE SAFETY CONSIDERATION (MOST STRINGENT SHALL APPLY) A. CORRIDOR WIDTH (IBC SECTION 1016.2, LSC 32.3.2.3.3) 1. CORRIDOR / AISLE WIDTH (50 OR LESS) B. DEAD END (IBC SECTION 1016.3, LSC 32.3.2.5.4) 1. DEAD END TRAVEL DISTANCE PROJECT OWNER EXIST. 5'-0" WIDTH TO REMAIN 20 FEET MAXIMUM C. TRAVEL DISTANCE (IBC SECTION 1013, LSC 32.3.2.6) 1. ANY POINT TO AN EXIT (SPRINKLERED) 2. DOOR OF ANY ROOM TO AN EXIT 3. THROUGH ADJOINING ROOM 4. EXIT ACCESS DOOR TO EXIT 5. ANY ROOM IN EXCESS OF 2,000 S.F. 6. ANY ROOM TO A CORRIDOR DOOR 7. CORRIDOR DOOR TO NEAREST EXIT (ACTUAL) 98 FT 75FT NOT PERMITTED ___ 2 EXIT ACCESS DOORS 75 FT ___ D. DOOR WIDTH AND HEIGHT 1. MINIMUM CLEAR EXIT WIDTH 2. MINIMUM HEIGHT 3. MAXIMUM SINGLE LEAF WIDTH 32" 80" 32" E. INTERIOR FINISHES (IBC SECTION 803.5, LSC 32.3.3.3) 1. EXIT ENCLOSURES 2. LOBBIES AND CORRIDORS 3. OTHER SPACES 4. ROOMS OR AREAS 5. PUBLIC TOILETS CLASS A CLASS A CLASS B CLASS B / C (PER OCCUPANCY A OR B) IBC SECT. 1210 TS.0 TS.1 ADA.1 A0.1 A1.0 AD.1 A1.1 A1.5 A5.1 COVER SHEET GENERAL NOTES, EGRESS PLAN ADA STANDARDS SPECIFICATIONS ENLARGED SITE PLAN MAIN LEVEL DEMOLITION PLAN MAIN LEVEL FLOOR PLAN MAIN LEVEL REFLECTED CEILING PLAN DOOR SCHEDULE, ELEV. & DETAILS INTERIOR DESIGN ID1.0 ID1.1 FINISH PLAN FURNITURE PLAN MECHANICAL F. HEAT DETECTORS 1. HEAT DETECTORS SHALL BE PROVIDED IN ALL COMMON AREAS, SUCH AS LOUNGE (IFC 1007.2.9.1.4). G. SMOKE DETECTORS 1. REQUIRED IN ALL COMMON AREA AND INTERIOR CORRIDORS SERVIING AS A REQUIRED EXIT FOR EACH OCCUPANT LOAD OF 10 OR MORE (IBC SECT. 310.9, NFPA 32.3.3.4.7, IFC 1007.2.9.13). PROJECT LOCATION: XXXX STREET ADDRESS CITY, STATE ZIP ARCHITECTURAL H. FIRE ALARM 1. MANUAL AND AUTOMATIC FIRE ALARM SYSTEMS REQUIRED (IFC 1007.2.9.11) LOAD OF 10 OR MORE (IBC 310.9, NFPA 32.3.3.4.7, IFC 1007.2.9.13) EXCEPTION: A SEPARATE FIRE ALARM SYSTEM NEED NOT BE PROVIDED IF THE BUILDING IS PROTECTED THROUGHOUT BY AN APPROVED, SUPERVISED FIRE SPRINKLER SYSTEM CONFORMING WITH THE IBC AND HAVING A LOCAL ALARM TO NOTIFY ALL OCCUPANTS. 2. PULLS AT MAIN EXITS. (EXIST. TO REMAIN) 3. FIRE ALARM AUTOMATIC NOTIFICATION REQUIRED. (EXIST. TO REMAIN) I. KEY BOX 1. KEY BOXES SHALL BE INSTALLED IF ACCESS TO THE STRUCTURE IS UNDULY DIFFICULT, WHERE IMMEDIATE ACCESS IS REQUIRED, OR WHERE A CENTRALLY OR REMOTELY MONITORED FIRE PROTECTION SYSTEM IS INSTALLED. THE APPROVED KEY BOX SHALL BE A "KNOX BOX(TM)" WHICH SHALL BE ORDERED THROUGHT THE CITY OF COLORADO SPRINGS FIRE DEPARTMENT PREVENTION DIVISION (CSFPD) (IFC WITH LOCAL AMENDMENT) 2. CSFPD REQUIRES KEY BOX TO BE INSTALLED ADJACENT TO MAIN ENTRANCE 10-12 FEET ABOVE GRADE. M-1 M-2 M-3 MECHANICAL LEGEND AND GENERAL NOTES MECHANICAL DEMOLITION PLANS MECHANICAL NEW PLANS ELECTRICAL E1.0 E2.0 E3.0 E4.1 E4.2 ELECTRICAL LEGEND ELECTRICAL SCHEDULES ELECTRICAL DEMOLITION FLOOR PLAN NEW WORK LIGHTING PLAN NEW WORK POWER PLAN PUBLIC SAFETY BUILDING - UCCS SHEET INDEX 3.0 MEANS OF EGRESS (IBC 1003) MILITARY AND STUDENT VETERAN CENTER REMODEL * COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES, LAWS AND REGULATIONS. B. PORTABLE FIRE EXTINGUISHERS (IFC 906) TO BE PROVIDED AT KITCHEN AREA(S) C. FIRE ALARM AND DETECTION SYSTEMS (IBC 907) EXISTING TO REMAIN, RELOCATED AS NEEDED COVER SHEET BID SET DATE: DATE: 01/29/2016 DRAWN BY: TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: VICINITY MAP NOT TO SCALE NORTH TS.0 REVISIONS GENERAL NOTES ABBREVIATIONS DATE FOR BOTTOM OF STRUCTURE 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. PARKING, TRASH REMOVAL, TEMPORARY FACILITIES, DELIVERIES 1. 2. C'SNK C.B. C.C.T. C.J. CMU CT C/T BD. CAB. CG CHEM. CLG. CL. CLR. C.O. COL. COMP. CONC. CONF. CONST. CONT. CORR. CPT CNTR. COUNTERSUNK CATCH BASIN CUBICLE CURTAIN TRACK CONTROL JOINT CONCRETE MASONRY UNIT CERAMIC TILE CHALK/TACK BOARD CABINET CORNER GUARD CHEMICAL CEILING CLOSET CLEAR CASED OPENING COLUMN COMPUTER CONCRETE CONFERENCE CONSTRUCTION CONTINUOUS CORRIDOR CARPET COUNTER DIA. DIAG. DIM. DIR. DISP. DS DTL. DWGS. DIAMETER DIAGONAL DIMENSION DIRECTOR DISPENSER DOWNSPOUT DETAIL DRAWINGS E.J. EWC EA. E.H.O.D. ELEC. EL. ELEV. ENCL. EQUIP. EXST. EXP. EXT. EXPANSION JOINT ELECTRIC WATER COOLER EACH ELECTROMAGNETIC HOLD OPEN DEVICE ELECTRICAL ELEVATOR ELEVATION ENCLOSURE EQUIPMENT EXISTING EXPOSED/EXPANSION EXTERIOR F.D. FEC F.F.E. FH FIN. FIXT. FLR. FDN. FTG. FZR. F.V. FLOOR DRAIN FIRE EXTINGUISHER CABINET FINISH FLOOR ELEVATION FIRE HYDRANT FINISH FIXTURE FLOOR FOUNDATION FOOTING FREEZER FIELD VERIFY G.B. GA GRAB BAR GUAGE H.B. HC HCM HD. H.M. HORIZ. HOUR HRDBD HOSE BIB HANDICAPPED HANDICAPPED MIRROR HEAD HOLLOW METAL HORIZONTAL HR. HARDBOARD I.D. ILLUM. IN. INFO. INSUL. I/T INT. INV. INSIDE DIAMETER ILLUMINATOR INCH INFORMATION INSULATION INSULATED TEMPERED INTERIOR INVERT JT. JST. JST. BRG. JOINT JOIST JOIST BEARING K.D. KIT. KNOCK DOWN FRAME KITCHEN LAB. LAV. L.F. LKR. LOC. LABEL LAVATORY LINEAL FOOT / LINEAR FOOT LOCKER LOCATION MAINT. MANG. MAT'L MAX. MECH. MFR. MGT. MH MIN. MIR. MISC. M.O. MR/S MTD. MTL. MAINTENANCE MANAGEMENT MATERIAL MAXIMUM MECHANICAL MANUFACTURER MANAGEMENT MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MIRROR WITH SHELF MOUNTED METAL N/A N.I.C. NO. NOM. NTS NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE O/ O.C. O.D. O.D. O.F.E. OPER. OPNG. OPP. OVHD OVER ON CENTER OVERFLOW DRAIN OUTSIDE DIAMETER OWNER FURNISHED EQUIPMENT OPERATIONS OPENING OPPOSITE OVERHEAD P PART'N P.H. PLAS. PLAM. PLYWD. P.O. PROF. PROP. P.R.V. PT P.T. PTD PAINT PARTITION PANIC HARDWARE PLASTER PLASTIC LAMINATE PLYWOOD POWER OPERATED PROFESSIONAL PROPERTY POWER ROOF VENTILATOR PORCELAIN TILE PRESSURE TREATED PAPER TOWEL DISPENSER QT QUARRY TILE R. R.D. R.O. RECPT. REF. REINF. REQ'D R.H. RM. RUB. RADIUS ROOF DRAIN ROUGH OPENING RECEPTION REFRIDGERATOR REINFORCING/REINFORCED REQUIRED ROOF HATCH ROOM RUBBER S&R SS S.S. S.C. SCHD. SCR SD SEC. SECT. SGNL. S.F. SHLVG. SHT. SIM. S.O.G. SPEC. SPECS SSS ST. STD. STL. STOR. STRUCT. SYS. SHELF AND ROD SANITARY SEWER STAINLESS STEEL SOLID CASED OPENING SCHEDULE SHOWER CURTAIN ROD SOAP DISH SECRETARY SECTION SIGNAL SQUARE FEET/FOOTAGE SHELVING SHEET SIMILAR SLAB ON GRADE SPECIAL SPECIFIATIONS STAINLESS STEEL SHELF STAIN STANDARD STEEL STORAGE STRUCTURAL SYSTEM T. TB TBL. TECH. TEL. TEMP. TIG TTIG TTLIG T.O.C. T.O.F. T.O.S. T.O.W. TPH T.S. TYP. TOILET TOWEL BAR TABLE TECHNICIAN/TECHNICAL TELEPHONE TEMPERED TINTED INSULATING GLASS TINTED TEMPERED INSULATING GLASS TINTED TEMPERED LAMINATED INSULATING GLASS TOP OF CURB TOP OF FOUNDATION TOP OF STEEL TOP OF WALL TOILET PAPER HOLDER TUBE STEEL TYPICAL U.N.O. UNLESS NOTED OTHERWISE VERT. VEST. VIN. VWC VERTICAL VESTIBULE VINYL VINYL WALL COVERING W.C./WC W.C. WC W/ W/O WD. WG WLD. WP. WSCT. WT. WHEELCHAIR WATER CLOSET WALL COVERING WITH WITHOUT WOOD WIRE GLASS WELDED WATERPROOF(ING) WAINSCOT WEIGHT YD. YARD TOP OF WALL BASE BID BLOCKING BEAM BEARING BRACKET/BRACKETS BOTTOM OF WALL BUILDING GALLON GALVANIZED GENERAL GYPSUM GYPSUM BOARD 5/8" GYPSUM BOARD, TAPE, TEXTURE, PAINT, EXTEND TO UNDERSIDE OF DECK OR 6" PAST ACT. END AT GYPSUM CEILING PER PLAN NOTES 3-5/8" (OR 6", PER PLAN) METAL STUD 5/8" GYPSUM BOARD, TAPE, TEXTURE, PAINT 01.29.16 3-5/8" (OR 6", PER PLAN) METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD, TAPE, TEXTURE, PAINT BASE AS SCHEDULED 3-5/8" (OR 6", PER PLAN) METAL STUD CHANNEL 3 WALL DETAIL (TYP.) 1 1/2" = 1'-0" SCHEDULE, WORK HOURS & BLDG ACCESS 1. 2. 3. 4. 5. 6. 7. Parking Garage DEEP LEG SLIP TRACK WORK TO BE STARTED AND COMPLETED AS STATED IN THE BID FORMS. THE SUITE WILL BE VACATED BY THE USERS DURING CONSTRUCTION. HOURS OF CONSTRUCTION ARE BETWEEN 7:00 AM - 10:00 PM OR AS OTHERWISE ARRANGED WITH THE PROJECT MANAGER. COORDINATE CONSTRUCTION ACTIVITIES WITH UCCS PROJECT MANAGER TO MEET OWNER'S SCHEDULE. ACTIVITIES CAUSING NOISE, VIBRATION, ODORS, DUST, ETC. AND ACTIVITIES WHICH REQUIRE CLOSURE OF PART OF THE BUILDING OR INTERRUPTION OF UTILITY SERVICES MUST BE COORDINATED WITH OWNER'S SCHEDULE. ARRANGE BUILDING ACCESS WITH UCCS PROJECT MANAGER. ALL MEANS OF EGRESS SHALL BE OPEN AND OPERATIONAL DURING CONSTRUCTION. CONTRACTOR SHALL NOT BLOCK OR OBSTRUCT HALLWAYS, STAIRS, DOORS, ETC. FOR HTE DURATION OF THE PROJECT. CONTRACTOR TO PROVIDE DUST PARTITION OF ADJACENT SPACES DURING CONSTRUCTION AND IS REPSONSIBLE FOR MAINTAINING THE CLEANLINESS OF THE SITE INCLUDING STAGING AREAS. EXISTING PARKING GARAGE STRUCTURE TO REMAIN 1S-1 100B 100C 100A 1R-1 UP 1S-4A 1R-2 BUSINESS: 100/GROSS = 7 PERSONS 1S-2 FREE PARKING IS AVAILABLE DURING SPRING BREAK MARCH 21 - MARCH 25, 2016. CONTRACTOR WILL BE RESPONSIBLE FOR PARKING FEES DURING OTHER TIMES. GENERAL CONTRACTOR IS REPSONSIBLE FOR TRASH AND RECYCLING REMOVAL. COORIDNATE DUMPSTER LOCATIONS WITH UCCS PROJECT MANAGER. 106 EXIST. TO 108 REMAIN EXIST. TO REMAIN 101 EXIST. TO REMAIN 1S-4 EXIST. TO REMAIN EXIST. TO REMAIN EXIST. TO REMAIN EXIST. TO REMAIN EXIST. TO REMAIN 1S-3 23 OCCUPANTS THIS EXIT STANDING COMPUTER STATION ACCESSORY SPACES EXIST. TO REMAIN 100E 102 104 105 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) 7. B.B. BLK'G BM. BRG. BRKT. B.O.W. BLDG. GAL. GALV. GEN. GYP. GYP. BD. EXIST. TO REMAIN 107 EXIST. TO REMAIN PUBLIC SAFETY BUILDING - UCCS 5. 6. AUTOMATIC DOOR ABOVE FINISHED FLOOR ACOUSTICAL ADDITIONAL ADJUSTABLE/ADJACENT ADMINIMSTRATION ALUMINUM APPROXIMATE & ASSISTANT @ ACOUSTICAL TILE CEILING MILITARY AND STUDENT VETERAN CENTER REMODEL 4. A.D. A.F.F. ACOUS. ADD'L. ADJ. ADMIN. ALUM. APPROX. AND ASST. AT ATC PLAN 2. 3. CONTRACTOR, SUBCONTRACTORS, SUPPLIERS, AND OWNER SHALL REVIEW AND VERIFY ALL NOTES, DIMENSIONS AND INFORMATION ON THESE DRAWINGS PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIES, OMISSIONS OR CHANGES TO THE ARCHITECT. IF ERRORS, OMISSIONS, OR QUESTIONS REGARDING THE DRAWINGS BECOME EVIDENT OR ARE SUSPECTED, THE ITEM SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO PROCEEDING WITH WORK. FAILURE TO DO SO SHALL RELIEVE THE ARCHITECT OF ANY LIABILITIES FOR ERRORS OR OMISSIONS IN THE PLANS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS FOR DIMENSIONS. THE CONTRACTOR SHALL VERIFY SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY WORK. ANY DISCREPANCIES FROM THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO PROCEEDING WITH WORK. ALL WORK IS TO BE PERFORMED IN A THOROUGH AND GOOD WORKMANSHIP-LIKE MANNER BY SKILLED WORKERS IN CONFORMANCE WITH THE BEST STANDARDS OR PRACTICES IN THE TRADE. ALL WORK SHALL COMPLY WITH APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES, ORDINANCES, RULES AND REGULATIONS. THE CONSTRUCTION SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY AND SAFE MANNER. DEBRIS SHALL BE PLACED IN TRASH RECEPTACLES OR BINS. FENCE OFF OPEN TRENCHES OR OTHER HAZARDS FROM TRESPASSERS. STORE VALUABLE MATERIALS, TOOLS, SUPPLIES OR APPLIANCES IN A LOCKED SPACE. CONFORM WITH NEIGHBORHOOD REGULATIONS FOR NOISE CONTROL, CLEAN-UP AND SITE CONDITIONS. ALL FEDERAL AND STATE SAFETY AND OSHA REGULATIONS SHALL BE ENFORCED FOR ALL WORK, EQUIPMENT AND CONSTRUCTION METHODS. IF ASBESTOS OR ASBESTOS-CONTAINING MATERIALS ARE ENCOUNTERED DURING DEMOLITION OR CONSTRUCTION, STOP WORK AND DO NOT DISTURB THOSE MATERIALS. CONSULT WITH A LICENSED ASBESTOS ABATEMENT PROFESSIONAL TO PROPERLY REMOVE THE MATERIALS PRIOR TO PROCEEDING. PROVIDE TEMPORARY SHORING FOR THE EXISTING STRUCTURE DURING DEMOLITION UNTIL THE NEW SUPPORTING STRUCTURE IS IN PLACE. LOCATE AND STAKE ALL EXISTING UNDERGROUND UTILITY LINES PRIOR TO EXCAVATION, TRENCHING OR DIGGING. REPLACE OR REPAIR ANY DAMAGE TO EXISTING LINES THAT MAY OCCUR. FOR ADDITIONS AND REMODELS: HIDDEN CONDITIONS EXIST AT THE TIME OF PREPARATION OF THESE DRAWINGS. IF EXPOSURE OF THESE CONDITIONS RESULT IN CONFLICTS WITH THE DRAWINGS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING PRIOR TO PROCEEDING WITH ANY WORK. ALL DIMENSIONS ARE FROM FACE OF NEW FRAMING, FACE OF EXISTING MASONRY, OR FACE OF FINISH ON EXISTING WALLS UNLESS NOTED OTHERWISE ON THE DRAWINGS. ALL GLASS WITHIN 18" OF FLOOR AND WITHIN A 24" ARC OF DOOR JAMBS TO BE TEMPERED GLASS. ALL GLASS WITHIN DOORS ALSO SHALL BE TEMPERED. ALL SMOKE DETECTORS SHALL BE PERMANENTLY WIRED AND INTERCONNECTED WITH BATTERY BACKUP. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. MANUALLY OPERATED EDGE OR SURFACE-MOUNTED FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED. APPLICABLE CODES: ALL WORK & MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE GOVERNING CODES AND APPLICABLE STANDARDS. NOTE TO THE GENERAL CONTRACTOR/BUILDER/TRADES: CONTRACTOR IS RESPONSIBLE FOR: DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE; FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF HIS/HER WORK WITH THAT OF ALL OTHER TRADES; FURNISHING ALL ITEMS REQUIRED FOR THE PROPER EXECUTION, COMPLETION, AND SATISFACTORY PERFORMANCE OF ALL WORK NECESSARY, INDICATED, REASONBLY INFERRED OR REQUIRED BY ANY CODE WITH JURISDICTION TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETE & PROPER FINISHED JOB. IN CASE OF ANY QUESTIONS OR NEED FOR FURTHER CLARIFICATION OF INFORMATION AND/OR DETAILS, CONTRACTOR SHOULD CONTACT THE ARCHITECT PRIOR TO FURTHER CONSTRUCTION OR FABRICATION OF ITEMS IN QUESTION. CONTRACTOR SHALL TAKE DIRECTION FROM DESIGNATED OWNER'S REPRESENTATIVE. MATERIAL SELECTION; MANUFACTURER, MAKE, MODEL NUMBER, COLOR, ETC., OF FINISH MATERIALS, APPLIANCES, ETC., SHALL BE SELECTED BY THE OWNER REPRESENTATIVE AND/OR ARCHITECT. SUBSTITUTIONS: NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE OWNER REPRESENTATIVE AND/OR ARCHITECT'S PRRIOR WRITTEN APPROVAL. GUARANTEE: THE ARCHITECT MAKES NO EXPRESSED OR IMPLIED GUARANTEE FOR PRODUCTS IDENTIFIED BY TRADE NAME OR MANUFACTURER. JOB CLEAN UP: ALL TRADES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE AND/OR RUBBISH CAUSED BY THEIR WORK. ALL RUBBING, TOOLS, SURPLUS SUPPLIES, AND MATERIALS SHALL BE REMOVED AT THE COMPLETION OF THE DAY'S WORK. LEAVE THE JOB IN A BROOM-CLEAN CONDITION. PROVIDE DUST CONTROL DAILY. DIMENSIONS: DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. ALL DIMENSIONS ARE TO FACE OF STUD OR TO FACE OF FRAMING UNLESS NOTED OTHERWISE. VERIFY ALL FRAMING DIMENSIONS AT CABINETS, ETC., TO INSURE PROPER FIT. ALL DIMENSIONS SHALL BE CONFIRMED AND CORRELATED BY THE CONTRACTOR AT THE JOB SITE. IN CASE OF ANY QUESTIONS, THE CONTRACTOR SHOULD NOTIFY THE ARCHITECT FOR FURTHER CLARIFICATION. SHOP DRAWINGS & CONSULTANT'S DRAWINGS: REFER TO SHOP DRAWINGS AND CONSULTANT'S DRAWINGS FOR FURTHER PROJECT SCOPE AND COORDINATION REQUIREMENTS. NEW WORK TO BLEND INTO EXISTING. FINISH TO NEAREST CORNER OR BREAK IN MATERIAL TYPE. PROVIDE J-STRIP AT EDGES OF GYP. BOARD AGAING DISSIMILAR MATERIALS. CAULK FOR NEAT APPEARANCE AND TO PREVENT WATER PENETRATION. PRIOR TO DEMOLITION, CONTRACTOR TO VERIFY BEARING WALLS & NOTIFY ARCHITECT PRIOR TO ANY REMOVAL OR MODIFICATION OF THESE WALLS. RETURN ALL BALLASTS & ELECTRICAL COMPONENTS TO OWNER. PACKAGE FLOURESCENT BULBS UNBROKEN & RETURN TO OWNER. CONTRACTORS ARE RESPONSIBLE FOR COORDINATING WORK WITH OTHER TRADES, AND OWNER'S SELF-PERFORMED WORK WHEREVER AND WHENEVER THEY OVERLAP. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE INSPECTION SERVICES PROVIDED BY A STATE INSPECTOR. FEES FOR MEP, FIRE DEPT. FEES, AND REQUIRED PERMITS TO BE BY GENERAL CONTRACTOR. FEES FOR STATE ARCHITECT INSPECTIONS BY OWNER. ALL ELECTRICAL WORK WILL NEED TO BE PERFORMED BY A MASTER ELECTRICIAN WHO SHALL VERIFY THE LOAD CAPACITY OF ALL CIRCUITS AND PANELS BEING ADJUSTED. THE MASTER ELECTRICIAN SHALL SUBMIT A STATEMENT TO THE STATE INSPECTOR CERTIFYING THAT ALL AFFECTED LOAD CAPACITIES HAVE BEEN VERIFIED PRIOR TO FINAL INSPECTION. FLOOR 1. GENERAL NOTES, EGRESS PLAN BID SET LOUNGE w/OUT FIXED SEATS: 15/NET = 40 PERSONS 103 LONGEST PATH OF TRAVEL = 98 FT 1 CODE / EGRESS PLAN 1/8" = 1'-0" BUSINESS 100/GROSS = 23 PERSONS TOTAL SEATED WAITING AREA: 15/NET = 4 PERSONS TOTAL 29 OCCUPANTS THIS EXIT BUSINESS: 100/GROSS = 2 PERSONS TOTAL BUSINESS: 100/GROSS = 5 PERSONS TOTAL DATE: DATE: 01/29/2016 DRAWN BY: 29 OCCUPANTS THIS EXIT TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: TS.1 ACCESSIBILITY REQUIREMENTS: REVISIONS (ALL REFERENCES TO CHAPTERS, SECTIONS OR TABLES ARE TO ICC/ANSI 117.1-2009.) DATE PROTRUDING OBJECTS (Ch.3): A) B) FOR PROTRUDING WALL MOUNTED OBJECTS BETWEEN 27" AND 80" (A.F.F.) SHALL NOT PROTRUDE FROM THE WALL GREATER THAN 4". BARRIERS SHALL BE PROVIDED TO WARN VISUALLY IMPAIRED PERSONS IN CASES WHERE CLEAR HEADROOM PROVIDED IS REQUIRED TO BE LESS THAN 80" CLEAR. GROUND & FLOOR SURFACES (Ch.3): A) B) C) D) GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. CHANGES IN LEVELS GREATER THAN 1/4" SHALL HAVE TREATED EDGES. ALL CARPETS, WHERE APPLICABLE, SHALL HAVE A PILE THICKNESS OF NO GREATER THAN 1/2" AND LEVEL LOOP OF LEVEL CUT PILE SHALL BE PROVIDED UNLESS OTHERWISE SPECIFIED. GRATINGS LOCATED IN WALKING SURFACES OR ALONG ACCESSIBLE ROUTES SHALL HAVE SPACED OPENINGS NO GREATER THAN 1/2" IN ONE DIRECTION. GRATINGS WITH LONG DIMENSIONAL OPENINGS SHALL BE ORIENTED PERPENDICULAR TO TRAVEL. CONTROLS & OPERATING MECHANISMS (Ch.3): A) CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. OPERATION FORCE SHALL NOT EXCEED FIVE POUNDS-PER-FOOT. ACCESSIBLE ROUTES (Ch.4): 01.29.16 ACCESSIBLE ROUTES SHALL BE PROVIDED FROM PUBLIC PARKING AND TRANSPORTATION AREAS. SEE ITEMS UNDER PARKING & PASSENGER ACCESS. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED THAT CONNECTS ACCESSIBLE FACILITIES ON THIS SITE. B) ALL ACCESSIBLE ROUTES SHALL HAVE A WIDTH GREATER THAN OR EQUAL TO 36" (MIN.). C) ALL ACCESSIBLE ROUTES SHALL HAVE CLEAR HEADROOM GREATER THAN OR EQUAL TO 80" (MIN.). D) ALL ACCESSIBLE ROUTES SHALL HAVE LINEAR SLOPE OF LESS THAN OR EQUAL TO 5% (MAX.) AND A CROSS SLOPE OF LESS THAN OR EQUAL TO 2% (MAX). E) LEVEL CHANGES IN ACCESSIBLE ROUTES SHALL NOT EXCEED 1/2" (MAX.) WHERE A CURB, CURB RAMP, ELEVATOR, OR PLATFORM LIFT IS NOT PROVIDED. F) ALL ACCESSIBLE ROUTES SHALL PROVIDE A MEANS OF CONNECTION TO EMERGENCY EGRESS OF TO AN ACCESSIBLE AREA OF RESCUE ASSISTANCE. DOORS & OPENINGS (Ch.4): 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) A) A) B) DOORS SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WITH DOOR OPEN 90 DEGREES. NON-AUTOMATIC DOOR APPROACHED SHALL HAVE MANEUVERING CLEARANCES THAT ARE COMPLIANT WITH DESIGNATED APPROACH CONDITIONS FOUND IN TABLE 404.2.3.1. C) ACCESSIBLE EXTERIOR DOOR THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT. D) ALL DOOR HANDLES, PULLS, LATCHES, AND LOCKS SHALL BE OF A SHAPE THAT IS EASY TO GRASP IN ONE HAND AND SHALL BE MOUNTED NO HIGHER THAN 42" A.F.F. E) THE MAXIMUM OPENING FORCE FOR ALL INTERIOR DOORS AND EXTERIOR SLIDING OR FOLDING DOOR SHALL BE FIVE POUNDS-PER-FOOT, AND CLOSERS SHALL BE ADJUSTED SO THAT FROM A 70 DEGREE OPEN POSITION, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH. RAMPS (Ch.4): A) B) C) D) CURB RAMPS SHALL BE PROVIDED AT ALL LOCATIONS WHERE ACCESSIBLE ROUTES INTERSECT CURBS. MAXIMUM SLOPE OF RAMP IN DIRECTION OF TRAVEL SHALL NOT EXCEED 1:20 AND SIDE FLARE SLOPE SHALL NOT EXCEED 1:10. RAMPS SHALL BE WHOLLY CONTAINED WITHIN MARKED (PAINTED) ZONES IN LOCATIONS WHERE ACCESS WILL NOT BE OBSTRUCTED BY PARKED VEHICLES. EXIT/ENTRANCE RAMPS SHALL NOT EXCEED A SLOPE OF 1:12 IN THE DIRECTION OF TRAVEL AND SHALL NOT RISE GREATER THAN 30" WITHOUT A LANDING. RAMPS LESS THAN OR EQUAL TO 30" IN LENGTH SHALL HAVE A MINIMUM WIDTH OF 36". RAMPS GREATER THAN 30" IN LENGTH SHALL HAVE A CLEAR WIDTH OF 44". RAMP LANDINGS SHALL BE AT LEAST AS WIDE AS THE WIDTH OF RAMP LEADING TO IT AND SHALL HAVE A MINIMUM CLEAR LENGTH OF 60". HANDRAILS SHALL BE PROVIDED IF RAMP RISE IS GREATER THAN 6". SEE "HANDRAILS & GRAB BARS". ELEVATORS (Ch.4): A) B) C) D) QUANTITY OF ACCESSIBLE PARKING SPACES PROVIDED COMPLIES WITH TABLE 1106.1 OF SECTION 1106 OF THE 2009 INTERNATIONAL BUILDING CODE. ACCESSIBLE PARKING SPACES SHALL BE LOCATED AT THE SHORTEST POSSIBLE DISTANCE FROM ACCESSIBLE ENTRANCES. PARKING SPACES SHALL BE DESIGNATED WITH APPROPRIATE SIGNAGE AND ADDITIONAL SIGNAGE SHALL BE PROVIDED FOR VAN ACCESSIBLE SPACES READING "VAN ACCESSIBLE". SIGNS SHALL BE LOCATED 60" MINIMUM ABOVE PAVING SURFACE. PARKING SPACES SHALL BE A MINIMUM OF 96" WIDE WITH ACCESSIBLE PASSENGER UNLOADING ZONES A MINIMUM OF 60" WIDE. DESIGNATED VAN SPACES SHALL HAVE A MINIMUM OF 96" WIDE ACCESSIBLE PASSENGER UNLOADING ZONES TO THE RIGHT OF THE PARKING SPACES AND ALL UNLOADING ZONES SHALL NOT HAVE A SLOPE GREATER THAN 2% IN ANY DIRECTION. STAIRS, EXTERIOR (Ch.5): A) B) C) FLIGHTS OF STAIRS SHALL HAVE 11" TREADS AND 7" CLOSED RISERS. HANDRAILS SHALL BE PROVIDED AT ALL STAIRS. SEE "HANDRAILS & GRAB BARS". EXTERIOR STAIRS SHALL BE DESIGNED SO THAT WATER WILL NOT ACCUMULATE ON WALKING SURFACES. ENTRANCES (Ch.5): A) REQUIRED ACCESSIBLE ENTRANCES SHALL PROVIDE ACCESSIBLE ROUTES FROM PUBLIC AREAS TO ACCESSIBLE SPACES WITHIN THE FACILITY. SEE "GROUND & FLOOR SURFACES". HANDRAILS & GRAB BARS (Ch.5): A) RAMP HANDRAILS: CONTINUOUS HANDRAILS SHALL BE PROVIDED EACH SIDE OF RAMP AND SHALL EXTEND 12" (MIN.) BEYOND TOP AND BOTTOM OF RAMP SEGMENT. HANDRAILS SHALL BE MOUNTED BETWEEN 34" AND 36" ABOVE RAMP SURFACE. B) STAIR HANDRAILS: CONTINUOUS GRIP SURFACE HANDRAILS SHALL BE PROVIDED EACH SIDE OF STAIRS AND SHALL EXTEND 12" (MIN.) BEYOND THE TOP RISER AND 12" (MIN.) PLUS THE WIDTH OF ONE TREAD BEYOND THE BOTTOM RISER. EXTENSIONS SHALL BE PARALLEL TO THE FLOOR. C) CLEAR SPACE BETWEEN HANDRAILS AND GRAB BARS FROM MOUNTING SURFACES SHALL BE 1-1/2" AND ENDS SHALL BE RETURNED SMOOTHLY TO WALL. D) TOILET ROOM GRAB BARS: POSITIONING AND EXTENT SHALL COMPLY WITH FIGURES 604.5.1 & 604.5.2. GRAB BARS SHALL WITHSTAND BENDING, SHEAR, AND TENSILE STRESSES OF 250 POUNDS-PER-FOOT (MIN.). GRAB BARS SHALL NOT ROTATE. E) REFER TO FIGURES 505.5 & 609.3 FOR NOMINAL SIZES AND SPACING OF HANDRAILS AND GRAB BARS. DRINKING FOUNTAINS (Ch.6): A) SPOUTS SHALL BE NO HIGHER THAN 36", MEASURED FROM THE FLOOR OR GROUND SURFACES TO THE SPOUT OUTLET. B) THE SPOUTS OF DRINKING FOUNTAINS AND WATER COOLERS SHALL BE AT THE FRONT OF THE UNIT, THE SPOUT SHALL PROVIDE A FLOW OF WATER AT LEAST 4" HIGH SO AS TO ALLOW THE INSERTION OF A CUP OR GLASS UNDER THE FLOW OF WATER. ON AN ACCESSIBLE DRINKING FOUNTAIN WITH A ROUND OR OVAL BOWL, AND ON AN ACCESSIBLE DRINKING FOUNTAIN PROVIDING ONLY A PARALLEL APPROACH COMPLYING WITH FREE-STANDING OR BUILT-IN UNITS (SEE 'E' BELOW), THE SPOUT MUST BE POSITIONED SO THAT FLOW OF WATER IS WITHIN 3" OF THE FRONT EDGE OF THE FOUNTAIN. C) CONTROLS SHALL COMPLY WITH FIGURE 602.5, AND SHALL BE FRONT MOUNTED OR SIDE MOUNTED NEAR THE FRONT EDGE. D) WALL- AND POST-MOUNTED CANTILEVERED UNITS SHALL HAVE A CLEAR KNEE SPACE BETWEEN THE BOTTOM OF THE APRON AND THE FLOOR OR GROUND AT LEAST 27" HIGH, 30" WIDE, AND 17"-18" DEEP. SUCH UNITS SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30" BY 48" TO ALLOW A PERSON IN A WHEELCHAIR TO APPROACH THE UNIT FACING FORWARD. E) FREE-STANDING OR BUILT-IN UNITS NOT HAVING A CLEAR SPACE UNDER THEM SHALL HAVE A CLEAR FLOOR SPACE AT LEAST 30" BY 48" THAT ALLOWS FOR A PERSON IN A WHEELCHAIR TO MAKE A PARALLEL APPROACH TO THE UNIT. THIS CLEAR FLOOR SPACE SHALL COMPLY WITH FIGURE 602.5. TOILET ROOMS (Ch.6): A) B) C) D) E) F) G) H) WATER CLOSETS SHALL BE 17"-18" FROM TOP OF RIM TO FINISH FLOOR. URINALS SHALL BE A MAXIMUM OF 17" FROM THE TOP OF ELONGATED RIM TO FINISH FLOOR. GRAB BARS SHALL BE PROVIDED. SEE "HANDRAILS & GRAB BARS". FLUSH CONTROLS SHALL BE MOUNTED ON WIDE SIDE OF TOILET AREA NO HIGHER THAN 44" A.F.F. SEE "CONTROLS & OPERATING MECHANISMS". ALL DISPENSERS SHALL BE MOUNTED WITHIN REACH PER FIGURE 604.7. TOILET STALL SIZE AND ARRANGEMENT SHALL COMPLY WITH DIMENSIONAL REQUIREMENTS DESIGNATED IN FIGURES 604.8.2 & 604.9. 30" BY 48" FLOOR CLEARANCES SHALL BE MAINTAINED ON APPROACHES TO LAVATORIES AND URINALS. LAVATORIES SHALL NOT BE MOUNTED HIGHER THAN 34" TO RIM ABOVE FINISH FLOOR AND 28" MINIMUM FROM BOTTOM OF APRON TO FINISH FLOOR. LEVER-OPERATED, PUSH TYPE, OR ELECTRONICALLY CONTROLLED MECHANISMS SHALL BE USED TO OPERATE FAUCETS. MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF REFLECTIVE SURFACE NO HIGHER THAN 40" A.F.F. PUBLIC SAFETY BUILDING - UCCS CALL BUTTONS AND KEYPADS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 308, MEASURED TO THE CENTERLINE OF THE HIGHEST OPERABLE PART. B) A 30" BY 48" CLEAR FLOOR SPACE SHALL BE LOCATED AT CALL CONTROLS AND COMPLY WITH SECTION 305. PARKING & PASSENGER ACCESS (Ch.5): MILITARY AND STUDENT VETERAN CENTER REMODEL A) ADA STANDARDS ALARMS (Ch.7): A) SIGNAGE & DETECTABLE WARNINGS (Ch.7): A) ROOMS AND SPACES WHERE HANDICAP FACILITIES ARE PROVIDED (SUCH AS RESTROOMS) SHALL HAVE RAISED AND BRAILLE AND PICTORIAL SYMBOL SIGNS MOUNTED TO THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR FRAME AT 60" A.F.F. TO CENTER OF THE SIGN. ACCOMPANYING DESCRIPTIVE CHARACTERS SHALL BE MOUNTED BELOW THE SIGN. RE: FIGURES 703.3.10 & 703.3.11. TELEPHONES (Ch.7): A) B) C) A CLEAR FLOOR SPACE OF 30" BY 48" SHALL BE PROVIDED IN FRONT OF TELEPHONES. COIN SLOT OF TELEPHONE SHALL BE 48" A.F.F. (MAX.) IF ONLY FRONTAL APPROACH IS POSSIBLE, OR 54" A.F.F. IF ONLY SIDE APPROACH IS POSSIBLE. ONE VOLUME CONTROL PHONE SHALL BE PROVIDED WITH APPROPRIATE SIGNAGE. TABLES, WORK SURFACES & SEATING (Ch.9): A) B) BID SET REFER TO MEP DRAWINGS FOR COMPLIANCE FOR THIS PROJECT. ALL SALES, SERVICE, AND RESTROOM COUNTERTOPS SHALL BE 34" A.F.F. (MAX.) 38" CLEAR SHALL BE PROVIDED IN ALL SERVICE LINES AND AISLES BETWEEN CHAIRS, TABLES, AND WALLS (MIN.). DATE: DATE: 01/29/2016 DRAWN BY: TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: ADA.1 DATE: PUBLIC SAFETY BUILDING - UCCS MILITARY AND STUDENT VETERAN CENTER REMODEL 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) REVISIONS DATE DRAWN BY: FOR 01.29.16 SPECIFICATIONS BID SET DATE: 01/29/2016 TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: A0.1 ALL INFORMATION THIS SHEET IS FOR BIDDING PURPOSES ONLY - FINAL DESIGN & CONSTRUCTION DOCUMENTS FOR SITE WORK WILL BE PROVIDED BY OWNER REVISIONS DATE 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) C O NO N ST T R FO U R C TI O N FOR 4'-0" MAPES CANOPY (OR EQUAL), DESIGN AND INSTALL PER MANUFACTURER 3D METAL LETTERS, BY OWNER UTILITY LOCATES BY CONTRACTOR GROUND LIGHTING SPOTLIGHT FOR CANOPY, CFCI, COOR. LOCATION W/ OWNER UTILITY BOXES TO BE RELOCATED BY CONTRACTOR 0" 5'- N. MI NEW 5'-0" CONC. WALKWAY TO MEET ADA & UCCS DESIGN GUIDELINES NEW TALL LIGHT POLE, OFCI, W/ CONC. BASE PER UCCS STANDARDS & TO MATCH EXIST. SITE LIGHTING IN HT., COLOR & FIXTURE EXIST. PLANTINGS, TO REMAIN UNLESS AS REQUIRED FOR NEW WALKWAY NEW OUTDOOR FURNITURE BY OWNER SIGNAGE BY OWNER EXIST. TRANSFORMER TO REMAIN RELOCATE FLAG POLE FROM FORESTER HOUSE PER UCCS DIRECTION EXIST. TRASH ENCLOSURE TO REMAIN EXIST. CONC. SIDEWALK TO REMAIN EXIST. SIDEWALK EXIST. DRIVE EXIST. COVERED ENTRY CANOPY COORDINATE REMOVAL OF ANY EXISTING PLANTINGS, ROCKS OR LANDSCAPE MATERIALS WITH UCCS OUTDOOR SERVICES SUPERVISOR EXIST. PATH IR C NT E G E R ADD ALT. #1 SITE IMPROVEMENTS WILL BE PART OF ADD ALT, #1 EXCEPT FOR THE RELOCATION OF EXISTING FLAGPOLE FROM FORSTER HOUSE. PUBLIC SAFETY BUILDING - UCCS EXISTING PARKING GARAGE STRUCTURE EXIST. RAIL MOUNTED AT T.O. RETAINING WALL TO REMAIN MILITARY AND STUDENT VETERAN CENTER REMODEL EXIST. TWO-STORY PUBLIC SAFETY BUILDING EXIST. PLANTINGS TO REMAIN ENLARGED SITE PLAN SITE DEVELOPMENT NOTES (FOR BIDDING PURPOSES ONLY): BID SET 1. CONC. PATH S.O.G. TO BE MIN. OF 2% SLOPE. DATE: 2. PATH TO BE 4" CONC SLAB W/ 6X6 WIRE MESH ON COMPACTED FILL W/ CONTROL JOINTS EVERY 5'-0" MIN. DATE: 01/29/2016 DRAWN BY: 3. CONC. PATH SHALL BY ACCESSIBLE ROUTE CODE COMPLIANT. 1 ENLARGED SITE PLAN TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: 1" = 20'-0" 0' 20' 50' ALL INFORMATION THIS SHEET IS FOR BIDDING PURPOSES ONLY - FINAL DESIGN & CONSTRUCTION DOCUMENTS FOR SITE WORK WILL BE PROVIDED BY OWNER 100' NORTH A1.0 REVISIONS DEMOLITION PLAN GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. DATE 01.29.16 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) DEMOLITION PLAN KEYNOTES NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 REMOVE EXISTING INTERIOR AND EXTERIOR WALLS SHOWN BOLDED AND DASHED, TYP., COORDINATE WITH NEW WORK REMOVE EXISTING DOOR. EXIST. FRAME TO REMAIN REMOVE PORTION OF WALL FOR NEW OPENING, SEE PLANS EXISTING CASEWORK TO BE REMOVED REMOVE EXISTING PULMBING FIXTURES REMOVE EXISTING CARPET/FLOORING AS NEEDED AND PREP FOR NEW REMOVE EXISTING CEILING GRID AND PREP FOR NEW SLAB CUT FOR BELOW SLAB SANITARY LINE FOR NEW SINK EXIST. FLOORING TO REMAIN. PREP FOR NEW FLOOR FINISH OVER EXIST. EXIST. CEILING GRID TO REMAIN. EXIST. WALL TO REMAIN, SHOWN SHADED. EXIST. CASE OPEN TO BE FILLED IN AROUND NEW DOOR SALVAGE PLAN KEYNOTES 1 2 3. FOR PROTECT ALL INTERIOR AND EXTERIOR BRICK DURING DEMOLITION PROTECT ALL INTERIOR FLOORING TO REMAIN DURING DEMOLITION SALVAGE & CLEAN ALL REMOVED BRICK, PREP FOR NEW WORK PRIOR TO DEMOLITION, REMOVE ALL FURNITURE AND EQUIPMENT. TURN OVER TO OWNER. PROVICE TEMPORARY SHORING FOR THE EXISTING STRUCTURE DURING DEMOLITION UNTIL THE NEW SUPPORTING STRUCTURE IS IN PLACE. SEE STRUCTURAL DRAWINGS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING ANY WORK OR WHEN DISCREPANCIES REVEAL THEMSELVES. ALL ELECTRICAL/TELEPHONE CONDUIT AND/OR PLUMBING WITHIN DEMOLISHED PARTITIONS AND/OR MILLWORK SHALL BE REMOVED TO THE POINT OF ORIGIN OR TERMINATED OR REMOVED UP TO A POINT REQUIRED FOR INTERFACE WITH NEW CONSTRUCTION. CONDUIT AND/OR PLUMBING SHALL NOT BE EXPOSED IN EITHER NEW OR EXISTING CONSTRUCTION. ALL WALLS NOTED TO BE REMOVED SHALL BE FULLY REMOVED. NO PONY WALLS ABOVE CEILING. RE-ATTACHED/RELOCATEANY ITEMS TO REMAIN WHICH MAY HAVE BEEN ATTACHED TO WALL. PATCH AND REPAIR EXISTING CONSTRUCTION / FINISHES, REPAIR. PREPARE FOR NEW FINISHES AS REQUIRED. CONTRACTOR TO VERIFY DISPOSAL OR STORAGE OF REMOVED EQUIPMENT SUCH AS APPLIANCES, PLUMBING FIXTURES, ETC. WITH OWNER. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION. REMOVE EXIST. FAN POWERED BOX FIRE SENSOR TEST SWITCHES (MULTIPLE LOCATIONS) TO BE REINSTALLED PER PLANS. ALL EXISTING FURNITURE AND EQUIPMENT TO BE REMOVED AND TURNED OVER TO THE OWNER, TYP. ALL EXISTING FIXTURES THIS ROOM TO BE REMOVED & TURNED OVER TO OWNER ALL EXISTING DOORS & HARDWARD TO BE TURNED OVER TO OWNER. 5 EXIST. MENS EXIST. ELEC. 9 10 1 9 10 9 10 9 10 5 EXIST. ELEC. 9 10 2 1 4 9 5 5 5 10 12 11 5 2 2 9 2 3 2 2 5 2 2 2 2 7 7 1 1 1 5 16'-7 1/8" ENTRY CORRIDOR 6 7 6 1 7 1 3 TYPICAL WALL LEGEND 5 EXISTING WALL TO REMAIN 4 2 EXISTING WALL TO BE REMOVED, REFER TO THE DEMOLITION PLAN 1 2 2 NEW 3-5/8" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES 2 5 1 1 1 6 6 6 NEW 1 HOUR RATED WALL CONSTRUCTION. PROVIDE 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE, CARRY FROM BOTTOM OF WALL TO UNDERSIDE OF STRUCTURAL DECKING, WHERE OCCURS. 7 7 2'-10" 8 7 NEW 6" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES 1 NOTES: 1. DIMENSIONS TO EXISTING CONSTRUCTION IS TO FACE OF FINISH. 2. DIMENSIONS TO NEW CONSTRUCTION IS TO FACE OF STUD. 3. MOISTURE MOLD RESISTANT GYP. BD. AT ALL WET LOCATIONS, TYP. 2 1 PUBLIC SAFETY BUILDING - UCCS MILITARY AND STUDENT VETERAN CENTER REMODEL EXISTING PARKING GARAGE STRUCTURE TO REMAIN MAIN LEVEL DEMOLITION PLAN BID SET DATE: DATE: 01/29/2016 DRAWN BY: TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: MAIN LEVEL DEMOLITION FLOOR PLAN AD.1 1/4" = 1'-0" 0' 1' 5' 10' 20' WALL HUNG FROM STRUCTURE ABOVE RECESSED LIGHT FIXTURES 3 TV NICHE ELEV. 5 1/4" = 1'-0" 2'-10" 1'-6" 2 TL-1 (TYP.) OWNER PROVIDED, 3 CONTRACTOR INSTALLED 4 PL-1 (TYP.) 5 6 7 CAB-1 (TYP.) 8 9 1'-3" COFFEE BAR ELEV. E 6 1/4" = 1'-0" 5'-10" 5'-2" 2'-0" NEW REF. 2'-0" STAFF KIT. ELEV. 1 1'-0" 2'-6" 2'-6" 2'-2" PL-1 (TYP.) 3'-9" SOFFIT SECTION @ TEKNION WALL 4 1/4" = 1'-0" HDW-1 (TYP.) 3'-0" HDW-1 (TYP.) CAB-1 (TYP.) EXIST. REF. TEKNION WALL PER MANUFACTURER SPEC/INSTALLATION, CONTRACTOR TO VERIFY & COOR. HTS. PRIOR TO ORDERING AND INSTALLATION OF TEKNION WALL 1'-0" 1/4" = 1'-0" FOR 1/4" = 1'-0" 17 18 20 21 GENERAL ARCHITECTURAL NOTES: 1. 2. 3. 22 23 24 25 26 27 28 29 30 31 PROTECT ALL EXISTING BRICK AND WALLS TO REMAIN DURING AND PRIOR TO CONSTRUCTION. NEW PAINT - TYP. AT ALL PAINTED WALLS & CEILINGS, SEE FINISH PLANS THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING BEFORE STARTING ANY WORK. PROVIDE NONCOMBUSTIBLE, FIRE RETARDANT TREATED WOOD BLOCKING IN WALLS AS REQUIRED FOR WALL MOUNTED MILLWORK, PANELS, EQUIPMENT, ACCESSORIES, SHELVING, WALL STOPS, AND FURNITURE. VERIFY LOCATION WITH FURNITURE VENDOR. REPAIR FLOOR TO SMOOTH LEVEL SURFACE BEFORE INSTALLING NEW FLOORING. FLOAT FLOOR AS REQUIRED TO ELIMINATE ANY CHANGE IN FINISH ELEVATION BETWEEN ADJACENT MATERIALS. ALL FLOOR PREP TO BE INCLUDED IN PRICING. PREP ALL COLUMN AND/OR WALL SURFACES AS REQUIRED TO RECEIVE NEW-LEVEL FOR FINISH PAINT. VERIFY AVAILABILITY OF MATERIALS TO BE USED FROM BUILDING STOCK W/ BUILDING MANAGEMENT. REMOVE ALL BLINDS PRIOR TO CONSTRUCTION AND RETURN TO OWNER. INSTALL BLINDS PER OWNER. NOTE: ALL ADHESIVE USED IN CONSTRUCTING NEW FACILITY TO BE NON-TOXIC AND ENVIRONMENTALLY SAFE. ALL NEW DOOR HDW AND ACCESSORIES TO BE PER BUILDING STANDARD. 4. 5. 6. 7. 8. 9. 10. 11. 10 11 12 13 14 15 16 3-5/8" MTL. STUDS @ 16" O.C. W/ 5/8" GYP. BOARD EA. SIDE TO BTM. OF STRUCTURE ABOVE (UNLESS NOTED OTHERWISE, U.N.O.), FOR COLOR & WALL FINISHES SEE INTERIOR DESIGN DRAWINGS 3-5/8" MTL. STUDS @ 16" O.C. W/ 5/8" GYP. BOARD EA. SIDE TO 6" ABV. CLG. HT. (UNLESS NOTED OTHERWISE, U.N.O.), FOR COLOR & WALL FINISHES SEE INTERIOR DESIGN DRAWINGS 6" MTL. STUDS @ 16" O.C. W/ 5/8" GYP. BOARD EA. SIDE (U.N.O.), FOR COLOR & WALL FINISHES SEE INTERIOR DESIGN DRAWINGS NEW PAINT ON EXIST. WALLS, COLOR & WALL FINISHES SEE INTERIOR DESIGN DRAWINGS +30" HIGH COUNTER, STANDARD DEPTH, SUPPORT BRACKETS TO BE PAINTED PT-1 5'-0" DIAMETER CLEAR TURN AREA 30" x 48" CLEAR FLOOR SPACE CLEAR FLOOR SPACE AS REQUIRED BY DOOR TYPE BAR SINK (SEE PLUMBING PLANS), PROVIDE CLEARANCES AND MOUNTING HEIGHT AS SHOWN ON SHEET ADA.1 BASE / UPPER CABINETS PER INTERIOR ELEVATIONS THIS SHEET COPIER PROVIDED AND INSTALLED BY OWNER EXIST. REFRIGERATOR, OWNER PROVIDED CONTRACTOR INSTALLED CUSTOM MILLWORK, DISPLAY CASE GLAZED BOTH SIDES. SEE DETAIL. COUNTERTOP PER INTERIOR DESIGN DRAWINGS, MOUNTED PER ADA.1 NEW SIGN BY OTHERS (UNDER SEPARATE REVIEW AND PERMIT) NEW STOREFRONT SYSTEM W/ INSULATED GLAZING, SEE STOREFRONT ELEVATIONS AND DETAILS ON A4-SERIES SHEETS FIRE EXTINGUISHER IN CABINET NEW REFRIGERATOR, OWNER PROVIDED CONTRACTOR INSTALLED WALL MOUNT TV IN RECESSED NICHE TEKNION WALL (SHOWN FOR REFERENCE ONLY) DETAILS PROVIDED BY FF&E IN THIS PACKAGE +34" HIGH COUNTER ON BASE CABINET PER INTERIOR ELEVATIONS THIS SHEET EXISTING DRINKING FOUNTAIN TO REMAIN CANOPY ABOVE, BY MANUFACTURER, MAPES CANOPY OR SIMILAR EXISTING FIRE EXTINGUISHER CABINET TO REMAIN EXISTING STORM DRAIN LINES TO REMAIN WALK-OFF MAT AT RECESSED ENTRY, SEE INTERIOR DESIGN DRAWINGS DISHWASHER, OWNER PROVIDED CONTRACTOR INSTALLED UNDER COUNTER MICROWAVE, OWNER PROVIDED CONTRACTOR INSTALLED ALUM. FRAME WITH OPAQUE GLAZING PAINT EXIST HM DOOR TO MATCH DOOR TYPE 3 01.29.16 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) 2 EXIST. MICRO. EXIST. CLG. TILE GRID TO REMAIN AND BE PATCHED AS NEEDED OWNER PROVIDED, CONTRACTOR INSTALLED 2'-10" 7'-8" 8'-4" 4'-8" DISHWASHER COFFEE BAR ELEV. S 1'-0"1'-5 1/2" 2'-0" 3-5/8" MTL. STUDS FIN. FLR. 1'-11 7/8" 2'-0" 2'-0" 1'-6" GYP. B.D ON 3-5/8" STUD WALL HUNG FROM STRUCTURE ABOVE. 6'-0" TV WALL MOUNT HARDWARD BY CONTRACTOR GYP. BD. (ALL SIDES) MICROWAVE DRAWER CAB-1 (TYP.) 2'-0" 3'-0" 8" 1'-6" 3'-0" 1'-0" TL-1 (TYP.) 55" TV OWNER PROVIDED, CONTRACTOR INSTALLED 2'-10" PL-1 (TYP.) 5'-2" DOUBLE BUNN COFFEE POT W/ BUILT-IN WATER LINE (OWNER PROVIDED CONTRACTOR INSTALLED) RECESSED WALL MOUNT TV NICHE NEW ACC. CLG. TILE GRID HUNG FROM STRUCTURE ABV. 7" PROVIDE BLOCKING FOR MOUNT HDW. SHELVES FOR COFFEE MUG STORAGE, PL-1 HDW-1 (TYP.) 3-3/4" NICHE DEPTH 3'-6" 1'-0 1/8" 3'-6" 2'-0" DATE NUMBER GYP. SOFFIT 2'-0" REVISIONS FLOOR PLAN KEYNOTES: 4 N.I.C. 4 SHARED OFFICE 1 ELEC. CLOS. 4 14'-3 3'-9 5/8" CASE OPEN. 3'-0" x 7'-0" 5 A1.1 6 8 7/8" 2 1 MECHANICAL ROOM 12'-4 7/8" 3/8 N.I.C. " 130 ° 8'-10 1/2" 95° TYPICAL WALL LEGEND 13'-5 1/4" 2'-5 3/4" 1 EXISTING WALL TO BE REMOVED, REFER TO THE DEMOLITION PLAN NEW 3-5/8" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES 8 NEW 6" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES 8 A5.1 24 NOTES: 1. DIMENSIONS TO EXISTING CONSTRUCTION IS TO FACE OF FINISH. 2. DIMENSIONS TO NEW CONSTRUCTION IS TO FACE OF STUD. 3. MOISTURE MOLD RESISTANT GYP. BD. AT ALL WET LOCATIONS, TYP. 31 16'-10" NORTH 4'-0" 3 8 Sim MAIN LEVEL FLOOR PLAN NEW 1 HOUR RATED WALL CONSTRUCTION. PROVIDE 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE, CARRY FROM BOTTOM OF WALL TO UNDERSIDE OF STRUCTURAL DECKING, WHERE OCCURS. EXIT ONLY 5 1/4" REAR ENTRY VESTIBULE EXISTING WALL TO REMAIN 8'-10 3/4" 3 1 10'-4 3/8" ° 135 26 2'-10" A1.1 29 CASE OPEN. 7'-0 5/8" 4'-0" x 7'-0" 2'-8" CPT 18 LVT 9'-5 1/8" 1 28 2 STUDENT PRINTER LOCATION, UCCS PROVIDED AND INSTALLED LOUNGE 6 25 5 2 4 FLOORING TRANSITION (TYP.) 22 8 5 T CP A5.1 1/4" = 1'-0" 2 90° T LV 4'-0 6 COMPUTERS R 27 1 12 22 /4" '-8 3 8 1'-11 1/4" N.I.C. 1 R2 1/8" 4'-9 1/4" WALL MOUNT TV SIGNAGE NEW CORR. ENTRY 2 8'-0 3/8" 11'-0 1/4" 3'-4 1/4" 13 2 2'-5 3/4" 7 1/2" ENTRY CORRIDOR A1.1 4" 1/ 2 10 STAFF SMALL MEETING 8 1 3 3/4" 9 4" 4'-5 3/4" 2" 20 3 7'-4 7/8" '-4 R 9'-3 1 /8" R8 '-3" CPT 1/ RECEPTION 4'-6 1/4" 13 2'-4" 10 2 2'- 1 7 5'- 1/ STAFF KIT. 8 130 ° 90° 13 1 EXIST. TO REMAIN 8 1 11 4'-11 1/4" 8 1 8 8 10 Sim 27 MAIN LEVEL FLOOR PLAN A1.1 7 1 11 A5.1 21 LV T A5.1 NEW DOOR TO MATCH EXIST. PATCH & REPAIR EXIST. WALL, & FLOOR FINISHES DAMAGED BY INSTALLATION. MATCH ALL EXIST. FINISHES. 2 4 CP T 8 7 N.I.C. 4 9 LVT 3'-0" 6 MIN. 8 4 8 12 17 5 23 ELECTRICAL ROOM 8 4 2 4 2 3'-10 1/4" (OR STAND.) 2'-1" 4 8 8 7 8 PRIVATE OFFICE 2 12'-7 5/8" 8 6 8 PRIVATE OFFICE 1 2 1'-10" 5 8 4 1 N.I.C. 8 4 4 SHARED OFFICE 2 42" CLEAR N.I.C. 4 MILITARY AND STUDENT VETERAN CENTER REMODEL EXIST. ELEC. 9'-6 3/8" EXIST. MENS 4 12'-5" 4 12'-2" 15 0' 1' 5' 10' PUBLIC SAFETY BUILDING - UCCS EXISTING PARKING GARAGE STRUCTURE TO REMAIN BID SET DATE: DATE: 01/29/2016 DRAWN BY: TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: A1.1 20' REVISIONS REFLECTED CEILING PLAN GENERAL NOTES NOTE: ALL FIRE SMOKE DAMPER TEST BUTTONS (6 EXISTING) AT EXISTING FAN POWER BOXES NEED TO BE RE-INSTALLED IN NEW CEILING. 1. CENTER CEILING GRID IN ROOMS, U.N.O. 2. ALL RECESSED ELECTRICAL FIXTURES, MECHANICAL GRILLES, DIFFUSERS, ETC. SHALL BE CENTERED IN CEILING GRID, U.N.O. 3. REFER TO ELECTRICAL PLANS FOR MORE DETAILED FIXTURE INFORMATION, TYP. DATE FOR RCP SYMBOL LEGEND CEILING MTD. LIGHT P CEILING MTD. PENDANT LIGHT RECESSED 6" CAN WALL MTD. LIGHT 01.29.16 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) NEW RECESSED LED TROFFER LIGHT W/ ACRYLIC LENSE OR INDIRECT LAY-IN REPLACE EXISTING W/ 2'x4 RECESSED LED TROFFER LIGHT W/ ACRYLIC LENSE OR INDIRECT LAY-IN NEW 2'x2' ACOUSTIC TILE CEILING GRID SYSTEM W/ LAY-IN PANELS. NEW 5/8" GYP. BD. CEILING NEW 1 HOUR RATED WALL CONSTRUCTION. PROVIDE 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE, CARRY FROM BOTTOM OF WALL TO UNDERSIDE OF STRUCTURAL DECKING, WHERE OCCURS. EXIST. MENS EXISTING CLG. GRID TO REMAIN EXISTING CLG. GRID TO REMAIN EXISTING CLG. GRID TO REMAIN SUPPLY AIR & RETURN AIR GRILLES PER MECH. DRWGS. EXIST. ELEC. N.I.C. PRIVATE OFFICE 1 SHARED OFFICE 2 SHARED OFFICE 1 PATCH & REPAIR CLG. GRID AS REQUIRED TO MATCH EXIST. EXIST. ELEC. N.I.C. PRIVATE OFFICE 2 EXIST. FAN POWERED BOX FIRE SENSOR TEST SWITCH TO BE REINSTALLED. N.I.C. N.I.C. EXISTING CLG. & LIGHTING TO REMAIN, PATCH & REPAIR AS REQUIRED B.O. ACC. CLG. TILE @ 8'-4" A.F.F. 2'-0" B.O. ACC. CLG. TILE @ 8'-4" A.F.F. RECEPTION B.O. ACC. CLG. TILE @ 8'-0" A.F.F. 1'-4" R 9 R 6'- EXIST. TO REMAIN 1/2" 5'-0" 5'-0" B.O. GYP. BD. SOFFIT @ 7'-8" A.F.F. 5'-0 2'-2 1/4" OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) 1'-3 3/4" 1 (TY 1" P.) B.O. ACC. CLG. TILE @ 8'-3" A.F.F. 4'-2" 1'-1 3/8" OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) /8" OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) 2'-0" LOUNGE B.O. GYP. BD. SOFFIT @ 7'-8" A.F.F. OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) EXISTING CLG. GRID TO REMAIN N.I.C. ELECTRICAL ROOM TYPICAL WALL LEGEND EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED, REFER TO THE DEMOLITION PLAN COMPUTERS A5.1 ALIGN SOFFIT W/ CORNER OF WALL EXIST. TO REMAIN B.O. ACC. CLG. TILE @ 8'-2" A.F.F. 6'-0" OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) NEW 1 HOUR RATED WALL CONSTRUCTION. PROVIDE 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE, CARRY FROM BOTTOM OF WALL TO UNDERSIDE OF STRUCTURAL DECKING, WHERE OCCURS. 2'-0" 1'-2" 6'-0" 6'-0" MAIN LEVEL REFLECTED CEILING PLAN NEW 6" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES B.O. ACC. CLG. TILE @ 8'-0" A.F.F. 2'-0" 6'-0" NEW 3-5/8" MTL. STUD WALL @ 16" O.C. W/ 5/8" GYP. BD. EA. SIDE TO UNDERSIDE OF DECK OR 6" PAST ACC. CLG. LOCATIONS PER PLAN NOTES REAR ENTRY VESTIBULE 3'-10" 12 1 STAFF SMALL MEETING 11 1'-4" B.O. ACC. CLG. TILE @ 8'-0" A.F.F. B.O. GYP. BD. SOFFIT @ 7'-8" A.F.F. N.I.C. " B.O. ACC. CLG. TILE @ 8'-4" A.F.F. PATCH & REPAIR AS REQUIRED ENTRY CORRIDOR EXIST. TO REMAIN 10 " 1'-0 .) P Y (T 3'-1 PATCH CLG. GRID TO MATCH EXIST. 1 '-1 8" 3/ PATCH & REPAIR AS REQUIRED 4'-2 7/8 " EXIST. TO REMAIN 8'-0 3/8" EXIST. TO REMAIN 8'-1 1/2" EXIST. TO REMAIN OR AS HIGH AS ALLOWABLE (FIELD VERIFY HT.) 6'-0" NOTES: 1. DIMENSIONS TO EXISTING CONSTRUCTION IS TO FACE OF FINISH. 2. DIMENSIONS TO NEW CONSTRUCTION IS TO FACE OF STUD. 3. MOISTURE MOLD RESISTANT GYP. BD. AT ALL WET LOCATIONS, TYP. 6'-0" MAIN LEVEL PUBLIC SAFETY BUILDING - UCCS EXISTING CLG. GRID TO REMAIN MILITARY AND STUDENT VETERAN CENTER REMODEL EXIST 2'x4' ACOUSTIC TILE CEILING GRID SYSTEM W/ LAY-IN PANELS. PATCH & REPAIR WITH EXISTING AS NEEDED. REPLACE ANY DAMAGED CLG. TILES IN AREAS WHERE EXIST. TO REMAIN BID SET DATE: DATE: 01/29/2016 DRAWN BY: TDG CHECKED BY: TDG PROJECT NO.: 15135 SHEET: A1.5 1/4" = 1'-0" 0' 1' 5' 10' 20' REVISIONS 2'-6" DATE FOR DOOR & FRAME SCHEDULE 6" Type Mark 1 2 3 5 TOP TRIM PIECE CASEWORK SPEC: Clear Alder to be finished to match: Wilsonart Cocobala 7942-07. Sample to be provided to designer for approval. GLASS DOORS W/ PUSH MAGNETIC CATCH AND KEYED LOCKS DOOR & FRAME SCHEDULE LEGEND DOOR HARDWARE NOTES ALUM. CTG CTLG FRGC H.M. P PF SS ST STL. TTG TTIG U.N.O. WD. NOTE 1. NOTE 2. NOTE 3. NOTE 4. NOTE 5. NOTE 6. NOTE 7. NOTE 8. NOTE 9. NOTE 10. NOTE 11. NOTE 12. NOTE 13. NOTE 14. NOTE 15. NOTE 16. NOTE 17. NOTE 18. NOTE 19. 10" ALUMINUM CLEAR TEMPERED GLASS CLEAR TEMPERED LAMINATED GLASS FIRE RATED GLASS CERAMIC HOLLOW METAL PAINT PREFINISHED STAINLESS STEEL STAIN (WOOD) STEEL TINTED TEMPERED GLASS TINTED TEMPERED INSULATED GLASS UNLESS NOTED OTHERWISE WOOD ELEVATION SEE SOLID CORE WOOD DOOR 2" 2" SEE 2" A 2" INSUL. TEMP. GLASS B HOLLOW METAL DOOR, INSULATED C D SCALE: 1/4" = 1'-0" GYP. BD. SOFFIT, LOCATION PER RCP 7 Sim FIELD VERIFY 5'-0 1/8" A5.1 3-5/8" MTL. STUDS @ 16" O.C. 10'-11 5/8" 3'-7 7/8" 3'-7 7/8" 2'-0" TEMP. TEMP. GLASS, SEE ELEVATIONS FOR DIMENSIONS SEE FLOOR PLAN FOR WALL TYPE 9 2 1/2" (TYP.) TEMP. GLASS TEMP. GLASS TEMP. 2 STOREFRONT ELEVATIONS GLASS & STOP WHERE OCCURS, SEE PLAN AND FRAME ELEVATION SCALE: 1/4" = 1'-0" NOTE: STOREFRONT ELEVATIONS ARE PROVIDED FOR GENERAL DESIGN INTENT AND LAYOUT. COORDINATE FINAL DIMENSIONS WITH CONDITIONS IN FIELD. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW TO VERIFY COMPLIANCE WITH DESIGN INTENT. TYP. JAMB DETAIL 1 1/2" = 1'-0" MANUFACTURER TO PROVIDE SHOP DRAWINGS FOR CANOPY PROVIDE PLASTIC SHIM AND NON EXPANSIVE SPRAY FOAM INSULATION BETWEEN DOOR AND SURROUNDING FRAMING VERIFY DOOR LOCATION WITH ARCHITECTURAL PLAN PROVIDE SEALANT BETWEEN DOR UNIT AND INTERIOR TRIM ENTIRE PERIMETER 1'-1" 4'-0" 2" (TYP.) 2" (TYP.) 3'-2 1/8" SUFACE MOUNTED 2"x2" MTL FRAME WITH OPAQUE TEMP. GLAZING PANELS, TO BE MOUNTED WITH MTL. ANGLE BRACKETS 2'-5 3/4" 2'-5 3/4" REPLACE EXIST. DOOR WITH FULL LITE EXT. DOOR, PER SCHEDULE OPACIFIER COLOR TO MATCH EXIST. 3'-6 1/2" FLD. VERIFY SIGN BY OWNER 2"X2" METAL FRAME, SURFACE MOUNTED 8'-6" GLASS & STOP WHERE OCCURS, SEE PLAN AND FRAME ELEVATION VETERAN CENTER 2" EXIST. PRECAST WALL EXIST. BRICK VENEER ANCHOR MUST BE ANCHORED INTO EXIST. PRECAST WALL BEYOND BRICK VENEER W/ STRUCTURAL GRADE EPOXY ANGLE PLATE LAG SCREW OPAQUE GLAZING PANEL DATE: CONT. SEALANT ALL SIDES DRAWN BY: 1/4" PLATE CHECKED BY: TDG 2X2 METAL FRAME PROJECT NO.: 15135 EXIST. SIDEWALK SIDE ELEVATION FRONT ELEVATION 5 ADA DOOR SILL DETAIL 1 1/2" = 1'-0" 6 TYP. HEADER DETAIL 1 1/2" = 1'-0" 8 ENTRY DETAIL 1/4" = 1'-0" (3" = 1'-0" ON ENLARGED PARTIAL PLAN) DOOR SCHEDULE, ELEV. & DETAILS BID SET 2'-11" 2" HM FRAME H.M. FRAME, SEALANT EA. SIDE, TYP. 1'-4" BOXED HEADER, TYP. 1 1/2" = 1'-0" MAPES CANOPY (OR EQUAL) DESIGNED AND INSTALLED PER MANUFACTURER MAPES CANOPY (OR EQUAL) BY MANUFACTURER, W/ TIEBACK RODS 2" (TYP.) STOREFRONT SECTION EXIST. HM DOOR FRAME 2" (TYP.) SEE FLOOR PLAN FOR WALL TYPE TIE BACK RODS W/ PLATE ANCHORED TO EXISTING WALL PER MANUFACTURER 1'-0" ALUM. STOREFRONT BTM. FRAME 2" 1'-7 1/8" 1/4" CLEAR STOREFRONT GLASS (NOT INSULT.) 8'-0" 2 1/2" (TYP.) 2 1/2" (TYP.) 1 1/2" MAX. 3'-5" 2 1/2" (TYP.) VERIFY DOOR LOCATION WITH ARCHITECTURE PLAN 6'-0" 8'-0" 3/4" = 1'-0" GLASS, SEE ELEVATIONS FOR DIMENSIONS 7 3'-7 7/8" 2 1/2" (TYP.) SOFFIT DETAIL H.M. FRAME, SEALANT EA. SIDE, TYP. CONT. SEALANT BOTH SIDES EXIST. CONC. S.O.G. TO FIT EXIST. OPEN. EXIST. CLG. TILE GRID TO REMAIN EXIST. WALL ALUM STOREFRONT DOOR, SEE STOREFRONT ELEVATION 2 DOOR ELEVATIONS NEW ACC. CLG. TILE GRID HUNG FROM STRUCTURE ABV. 2'-0" SEE SCHED. SOLID CORE WOOD DOOR EXIST. WALL TO REMAIN 3 5/8" MTL STUD @ 16" O.C. WALL HUNG FROM STRUCTURE ABOVE 2" CLEAR 1/4' TEMP. GLASS SEE SCHED. 2" 3/4" = 1'-0" 4" ALUM. STOREFRONT FRAME Comments 01.29.16 SCHED. SEE SCHED. DISPLAY CASE DETAIL ALUM. STOREFRONT FRAME, SEALANT EA. SIDE, TYP. Hardware Notes 1, 3, 8, 9 or 10, 1, 3, 8, 9 or 10, 1, 4, 6, 8, 9 or 10, 1, 3, 8, 9 or 10, 1-1/2 PR. BB HINGES (2 PR. FOR OVERSIZED DOORS) STOREROOM LOCKSET CLASSROOM LOCKSET PASSAGE LOCKSET PANIC HARDWARE WEATHERSTRIPPING AND SWEEP SMOKE SEAL THRESHOLD (1/2" MAX.) WALL STOP FLOOR STOP SWING HINGES SIGNAGE KICK PLATE PUSH PLATE REX (REQUEST TO EXIT) DSP (DLOOR STOP POSITION) CARD READER ELECTRIC STRIKE ALL GLASS IN THIS RATED DOOR AND FRAME TO BE FRGC SCHED. 12 Fire Rating N/A N/A N/A N/A ALL DOORS ARE 1-3/4" THICK (U.N.O.) ALL FRAMES ARE VIEWED FROM THE EXTERIOR SIDE, U.N.O. SEE DOOR AND FRAME SCHEDULE FOR ACTUAL DOOR SIZES. COORDINATE FRAME DIMENSIONS WITH DOOR SIZES. THE RATING OF THE DOOR FRAME SHALL BE EQUAL TO THE RATING OF THE DOOR.. REFER TO SHEET A4.2 FOR DOOR HEAD AND JAMB DETAILS, U.N.O. SEE STRUCTURAL SEETS FOR LINTELS AT DOOR HEADS, IF REQUIRED. THE PERIMETER OF ALL FRAMES SHALL BE CAULKED AT BOTH THE EXTERIOR FACE OF THE INTERIOR FACE. 2" NEW BOXED HEADER, TYP. Jamb Detail 9/A5.1 9/A5.1 9/A5.1, SIM. 201 East Las Animas Street, Suite 113 Colorado Springs, CO 80903 719.623.5641 (Phone) 719.623-5643 (Fax) WOOD FACE FRAME BASE TRIM PIECE 4 Head Detail 6/A5.1 6/A5.1 6/A5.1, EXIST. HEAD TO REMAIN PUBLIC SAFETY BUILDING - UCCS 1'-0" ADJACENT CURVED WALLS PLAN SECTION Frame Material Frame Finish Glazing HM PAINT HM PAINT HM PAINT FULL LITE ALUM. GLAZED STOREFRONT MILITARY AND STUDENT VETERAN CENTER REMODEL 8'-4" 7'-0" RECESSED LED PUCK LIGHT ABOVE WOOD FILLER PIECE AS NEEDED ADJUSTABLE GLASS SHELFS Door Finish STAINED, SEALED STAINED, SEALED PAINTED 4" 1. 2. 3. 4. 5. 6. 7. GLASS OR WOOD ADJUSTABLE SHELVES GLASS SHELF BEYOND B C D Door Material SOLID CORE WD DR SOLID CORE WD DR HOLLOW METAL ALUM. STORE. DOOR, FRAME, & GLASS GENERAL NOTES 3" WOOD STILE 2'-6" Door Elevation SEE SCHED. 2" WOOD FACE FRAME Height 7'-0" 7'-0" 7'-0" 7'-7" 2" LED PUCK LIGHT, WIRED FROM SOFFIT ABOVE Width 3'-0" 3'-0" 3'-0" 3'-1 1/4" DATE: 01/29/2016 TDG SHEET: ENLARGED PARTIAL PLAN A5.1 S N O I S I V E R EXIST. WOMENS SHARED OFFICE 1 PRIVATE OFFICE 1 PRIVATE OFFICE 2 SHARED OFFICE 2 CPT-1 & 2 CPT-1 & 2 CPT-1 & 2 PT-3 PT-3 PT-3 CPT-1 & 2 ELEC. CLOS. PT-3 MOP SINK ELECTRICAL ROOM 3 1 1 e t i u S 3 , t e0 9 e r t0 S8 e sO n x aC o a m, h PF s i ng An 3 r1 si 44 ap 6 LS 6 5 5 t . o sd 33 aa 22 Er 66 9. 9 1o l. 0o 11 2C 77 REF. CPT-1 ACC-1 CPT-1 & 2 CPT-1 & 2 ︶ LVT-1 LVT-1 ︵ ︵ LVT-1 NEW CORR. ENTRY ︶ STAFF KIT. ACC-1 CPT-1 SIGNAGE RECEPTION ELECTRICAL ROOM CPT-1 & 2 COMPUTERS ACC-1 REAR ENTRY VESTIBULE T-1 CPT-1 & 2 LVT-1 LVT-1 1 ACC-1 CPT-1 PED-1 FLOOR PLAN - II 1/4" = 1'-0" Interior Finish Selections: Accessories: ACC-1 Base: B-1 Cabinet: CAB-1 Manuf: Centiva Item #: ME003 - MetalEdge Trois Finish: 00179 - Steel Size: 1/4" Cap with 1/8" Wide Support Location: 1/4" CPT-1 to 1/8" LVT-1 Remarks: To Be Miter Cut In Field; Requires ME004- MetalEdge Quatre In 00040-Black Manuf: Johnsonite Product: Traditional Wall Base, DC-66 Item: Standard Toe 4" ; Rolled goods only Color: Ironstone 178 Nominal Size: 4" H Location: Standard Wall Base, UNO Manuf: Starmark Cabinets or Equal Door Style: Tempo Wood Type: Clear Alder Color Name: Slate Color Family: Gray Shelves: To Match Location: Lounge and Breakroom Remarks: CAB Sample Must be Provided and Approved By Designer Carpet: CPT-1 Paint: PT-1 PT-2 Manuf: Centiva Product: Fusion CFN Color: Sand 3724 Nominal Size: 12" x 36" Total Thickness: 0.120" Wear Layer Thickness: 32 mil Edge Treatment: Square Edge (SE) Recycled Content: 13.8%-27.5% Preconsumer Flexibility ASTM F137: Passes Dimensional Stability ASTM F2199: Passes Static Load ASTM F970: Passes Residual Indentation ASTM F1914: Excellent Flammability ASTM E648: CRF>0.45 watts/cm2 NFPA Class 1 Slip Resistance ASTM D2047: Passes >0.5 ADA Compliant Smoke Density ASTM E662: Passes <450 Dmc Resistance to Light ASTM F1515: Excellent Chemical Resistance ASTM F925: Excellent Resistance to Heat ASTM F1514: Excellent Installation Method: Unidirectional, Brick Pattern, Vertical East To West Installation: Per Manufacturer's Approved Products and Procedures Warranty: 20-Year Limited Commercial Wear Warranty Location: See Drawings Remarks: Provide 10% Attic Stock Manuf: Sherwin Williams Product: ProMar 400 Zero VOC Interior Latex Eg-Shel Color: SW7053 Adaptive Shade Finish: Eg-Shel LRV: 21% Location: Wall Standard, UNO Pedestrian Carpet: PED-1 Manuf: Sherwin Williams Product: ProMar 400 Zero VOC Interior Latex Eg-Shel Color: SW7051 Analytical Gray Finish: Eg-Shel LRV: 48% Location: Office Walls Manuf: Philadelphia Commercial Product: Step On It Tile Style #: 54587 Color: Running Late 87500 Size: 24" x 24" Construction: Multi-Level Pattern Loop Tufted Weight: 28 Gauge: 1/12 Stitches Per Inch: 8.8 Finished Pile Thickness: 0.152 Total Thickness: 0.293 Primary Backing: Synthetic Secondary Backing: Ecoworx Tile Radiant Panel: Class 1 NBS Smoke: Less Than 450 Exlectrostatic Propensity: Less Than 3.5kv Installation Method: Quarter Turn Installation: Per Manufacturer's Approved Products and Procedures Warranty: Lifetime Stain, Lifetime Performance Location: See Drawings Plastic Laminate: PL-1 Tile: T-1 Vinyl: VIN-1 Manuf: Nevamar Product: Blue Lunaria LU3001T Edge Banding: Self Bullnose Location: Countertops, Standard, UNO Manuf: Arizona Tile Product: H-Line Alabaster Glossy Nominal Size: 4" x 16" Grout: Laticrete, Sauterne #18 Location: Kitchen Backsplash Installation: Monolithic Manuf: 3M Vinyl Or Equal Product: Vinyl Window Applique Color: Matte Silver Location: MOD-1 Remarks: Design and Art File to be Provided by Owner MAIN LEVEL FINISH PLAN AND SPECIFICATIONS Bid Set DATE: 01/29/2016 KH, AR BV : . O N T C E J O R P 15135 : T E E H S Manuf: Sherwin Williams Product: ProMar 400 Zero VOC Interior Latex Eg-Shel Color: SW6257 Gibraltar Finish: Eg-Shel LRV: 13% Location: Reception Wall; See Drawings PT-3 : Y B D E K C E H C Manuf: My Knobs Or Equal Product: Solid Stainless Steel Bar Pull Item #: 1004-SS Size: 6.14" L x 1/2" Diameter x 3-3/4" Centers x 1-3/8" Projection Finish: Stainless Steel Location: Cabinet Standard, UNO Luxury Vinyl Tile: LVT-1 : Y B N W A R D Manuf: Milliken Style: BKB109 Backbeat - Modular Color: 130 DJ With Scarlet Nominal Size: 1m x 1m (39.4" x 39.4") Construction: Tufted, Textured Loop Yarn Type: Miliken-Certified WearOn Nylon Type 6,6 Dye Method: Millitron Tufted Face Weight: 20 oz/yd2 Gauge: 1/10 Stitches Per Inch: 10.3 Finished Pile Height: 0.14" Finished Pile Thickness: 0.11" Average Density: 7,793 Standard Backing: PVC-Free Comfort Plus ES Cushion Stain Repel/Resist: StainSmart Antimicrobial: AlphaSan AF Built-In Protection Recycled Content by Total Weight: 35.9% Pre-Consumer, 8.6% Post Consumer Flammability Radiant Panel ASTM-E-648: > 0.45 (Class 1) Smoke Density ASTM-E-662: < 450 Methenamine Pill Test ASTM D 2859: Self-Extinguishing Lightfastness (AATCC 16E): > 4.0 at 80 Hours Crocking (AATCC 165): > 4.0 Wet or Dry Installation Method: Monolithic Installation: Per Manufacturer's Approved Products and Procedures Warranty: Lifetime Limited Warranty Location: See Drawings Remarks: 50% CPT-1, 50% CPT-2; Provide 10% Attic Stock : E T A D CPT-2 Manuf: Milliken Style: FRS109 Freestyle - Modular Color: 130 DJ With Scarlet Nominal Size: 1m x 1m (39.4" x 39.4") Construction: Tufted, Textured Loop Yarn Type: Miliken-Certified WearOn Nylon Type 6,6 Dye Method: Millitron Tufted Face Weight: 20 oz/yd2 Gauge: 1/10 Stitches Per Inch: 10.3 Finished Pile Height: 0.14" Finished Pile Thickness: 0.11" Average Density: 7,793 Standard Backing: PVC-Free Comfort Plus ES Cushion Stain Repel/Resist: StainSmart Antimicrobial: AlphaSan AF Built-In Protection Recycled Content by Total Weight: 26% Pre-Consumer, 9% Post Consumer Flammability Radiant Panel ASTM-E-648: > 0.45 (Class 1) Smoke Density ASTM-E-662: < 450 Methenamine Pill Test ASTM D 2859: Self-Extinguishing Lightfastness (AATCC 16E): > 4.0 at 80 Hours Crocking (AATCC 165): > 4.0 Wet or Dry Installation Method: Monolithic Installation: Per Manufacturer's Approved Products and Procedures Warranty: Lifetime Limited Warranty Location: See Drawings Remarks: 50% CPT-1, 50% CPT-2; Provide 10% Hardware: Attic Stock HDW-1 PUBLIC SAFETY BUILDING CPT-1 & 2 PT -2 LVT-1 CPT-1 CPT-1 & 2 LOUNGE DISPLAY CASE REF. STAFF SMALL MEETING MILITARY AND STUDENT VETERAN CENTER REMODEL ENTRY CORRIDOR LVT-1 WALL MOUNT TV DISPLAY CASE EXIST. TO REMAIN R O F E T A D EXIST. MENS ID-1.0 S N O I S I V E R EXIST. EXIST. EXIST. EXIST. DESK-2 SHARED OFFICE 1 ELEC. CLOS. EXIST. QTY. 4 VF 1 VF 2 VF 3 ︶ PRIVATE OFFICE 2 DESK-2 EXIST. PRIVATE OFFICE 1 VF 4 EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. DESK-2 MOP SINK STG-1 STG-1 NEW CORR. ENTRY STG-5A STAFF KIT. ER PI O C STG-5 STG-4 STOR-1 STG-5A STG-1 STG-2 STG-2 ENTRY CORRIDOR STG-4 WALL MOUNT TV DESK-1 STG-2 TBL-4 STAFF SMALL MEETING STG-4 TBL-2 EXIST. STG-5 RECEPTION STG-5 STG-4 DESK-2 EXIST. STG-4 STG-4 STG-5A COMPUTERS TBL-4 STG-4 LOUNGE REF. STG-4 TBL-4 STG-4 STG-5 STG-4, QTY. 5 TBL-2 STG-5B TBL-3 STG-3 STG-3 STG-3 STG-3 TBL-3 STG-3 STG-3 TBL-4 TBL-1 MAIN LEVEL FURNITURE REFERENCE PLAN EXIST. STG-4 STG-4 STG-5A DESK-2 EXIST. STG-1 EXIST. TO REMAIN 1/4" = 1'-0" 22 EXIST. REF. MOD-1 1 ELECTRICAL ROOM EXIST. REAR ENTRY VESTIBULE ELECTRICAL ROOM PUBLIC SAFETY BUILDING EXIST. WOMENS EXIST. SHARED OFFICE 2 MILITARY AND STUDENT VETERAN CENTER REMODEL BROCHURE HOLDER EXIST. BROCHURE HOLDER ︶ STG-1 ︵ ︵ EXIST. EXIST. EXIST. EXIST. MENS EXIST. R O F E T A D EXIST. 3 1 1 e t i u S 3 , t e0 9 e r t0 S8 e sO n x aC o a m, h PF s i ng An 3 r1 si 44 ap 6 LS 6 5 5 t . o sd 33 aa 22 Er 66 9. 9 1o l. 0o 11 2C 77 MAIN LEVEL FURNITURE REFERENCE PLAN Bid Set : E T A D DATE: 01/29/2016 : Y B N W A R D KH, AR : Y B D E K C E H C BV : . O N T C E J O R P 15135 : T E E H S ID-1.1 Leffingwell Consulting Engineers, Inc. PUBLIC SAFETY BUILDING - UCCS MILITARY AND STUDENT VETERAN CENTER REMODEL 1315 North El Paso Street Colorado Springs, CO 80903 T: (719) 473-5998 E: GaryL@LeffingwellCE.com E:\Projects\2015 Projects\15041\Drawings\Mechanical\15041 Mechanical.dwg MECHANICAL LEGEND AND GENERAL NOTES BID SET: 01/29/2016 01/29/2016 LCE LCE 15135 M-1 0' 1' 5' 10' 20' EXIST. MENS EXIST. WOMENS Leffingwell Consulting Engineers, Inc. 1315 North El Paso Street Colorado Springs, CO 80903 T: (719) 473-5998 E: GaryL@LeffingwellCE.com ENTRY CORRIDOR 1 1/8" = 1'-0" ENTRY CORRIDOR 2 MAIN LEVEL PLUMBING DEMOLITION PLAN 1/8" = 1'-0" PUBLIC SAFETY BUILDING - UCCS EXIST. WOMENS MILITARY AND STUDENT VETERAN CENTER REMODEL EXIST. MENS MAIN LEVEL HVAC DEMOLITION PLAN E:\Projects\2015 Projects\15041\Drawings\Mechanical\15041 Mechanical.dwg MECHANICAL DEMOLITION PLANS BID SET: 01/29/2016 01/29/2016 LCE LCE 15135 M-2 0' 1' 5' 10' 20' EXIST. WOMENS ELEC. CLOS. EXIST. MENS ELECTRICAL ROOM SHARED OFFICE 1 PRIVATE OFFICE 1 SHARED OFFICE 2 PRIVATE OFFICE 2 Leffingwell Consulting Engineers, Inc. STAFF KIT. 1315 North El Paso Street Colorado Springs, CO 80903 T: (719) 473-5998 E: GaryL@LeffingwellCE.com ENTRY CORRIDOR RECEPTION MECHANICAL ROOM COMPUTERS STAFF SMALL MEETING LOUNGE REAR ENTRY VESTIBULE 1 1/8" = 1'-0" EXIST. WOMENS SHARED OFFICE 2 SHARED OFFICE 1 PRIVATE OFFICE 1 PRIVATE OFFICE 2 ELECTRICAL ROOM RECEPTION MILITARY AND STUDENT VETERAN CENTER REMODEL ENTRY CORRIDOR STAFF KIT. MECHANICAL ROOM COMPUTERS STAFF SMALL MEETING LOUNGE REAR ENTRY VESTIBULE 2 MAIN LEVEL PLUMBING NEW PLAN 1/8" = 1'-0" PUBLIC SAFETY BUILDING - UCCS ELEC. CLOS. EXIST. MENS MAIN LEVEL HVAC NEW PLAN E:\Projects\2015 Projects\15041\Drawings\Mechanical\15041 Mechanical.dwg MECHANICAL NEW PLANS BID SET: 01/29/2016 01/29/2016 LCE LCE 15135 M-3 0' 1' 5' 10' 20' SYMBOL DESCRIPTION SYMBOL LIGHT FIXTURES DESCRIPTION GENERAL NOTES SPECIAL SYSTEM SYMBOLS GENERAL: THESE DRAWINGS REMAIN THE SOLE PROPERTY OF SOL CHAVEZ AND ASSOCIATES AND MAY BE USED ONLY FOR THE PROJECT AS INDICATED BY NAME AND LOCATION. ANY OTHER USE REQUIRES PRIOR, WRITTEN PERMISSION. THE CONTRACTOR WILL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, TRANSPORTATION, LICENSES, FEES, PERMITS, ETC. TO COMPLETE THE ELECTRICAL WORK DESCRIBED ON THE DRAWINGS. THE CONTRACTOR WILL WARRANT EQUIPMENT, MATERIAL AND WORKMANSHIP FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. WARRANTY SHALL INCLUDE REPLACEMENTS OR REPAIRS WITHOUT COST TO THE OWNER DURING THE WARRANTY PERIOD. ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) 2011 AND ALL OTHER APPLICABLE LOCAL CODES AND ORDINANCES. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. PUSHBUTTON OPERATOR. CEILING MOUNTED SPEAKER RECESSED FLUORESCENT LIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. S S WALL MOUNTED SPEAKER SURFACE FLUORESCENT LIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. E NURSE/EMERGENCY CALL BUTTON N NURSE/EMERGENCY CALL BUTTON FLUORESCENT STRIP LIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. USE OF DRAWINGS: DO NOT SCALE FROM THE ELECTRICAL DRAWINGS. FOR EXACT LOCATIONS USE ARCHITECT'S DIMENSIONED DRAWINGS, SHOP DRAWINGS AND FIELD MEASUREMENTS. VERIFY ALL LOCATIONS WITH THE ARCHITECT PRIOR TO ELECTRICAL ROUGH-IN. COMMUNICATION SYSTEM SYMBOLS WALL BRACKET FLUORESCENT LIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. WIRING METHODS: ALL WIRING FOR LIGHTING AND POWER SYSTEMS WILL BE IN CONDUIT OR CABLE ASSEMBLIES APPROVED BY THE GOVERNING AUTHORITIES. CONDUCTOR SIZES SHOWN ARE BASED ON AMPACITIES FOR COPPER CONDUCTORS, UNLESS OTHERWISE NOTED. WHEN APPROVED BY ENGINEER, FEEDERS MAY BE ALUMINUM CONDUCTORS OF EQUIVALENT AMPACITIES. GROUNDING CONDUCTORS SHALL BE PROVIDED FOR ALL CIRCUITS SHOWN ON THE DRAWINGS. PROVIDE BLOCKING AND OTHER NECESSARY SUPPORTS IN WALLS AND CEILINGS FOR MATERIAL AND EQUIPMENT TO BE PROVIDED. BRANCH CIRCUIT NUMBERS SHOWN ON THE DRAWINGS MAY BE REARRANGED WITHIN A GIVEN PANELBOARD TO SUIT THE NEEDS OF THE INSTALLATION. ELECTRICAL BRANCH CIRCUITS SHALL BE BALANCED BETWEEN LINES AND PHASES. MULTIWIRE BRANCH CIRCUITS SHALL HAVE A MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNDERGROUNDED CONDUCTORS AT THE POINT WHERE BRANCH CIRCUITS ORIGINATE (HANDLE TIES ARE AN APPROVED MEANS). THE GROUNDED AND UNDERGROUNDED CONDUCTOR OF EACH MULTIWIRE BRANCH CIRCUIT SHALL BE GROUPED BY WIRE TIES AT ONE LOCATION IN PANELBOARD. ALL PATIENT CARE AREAS SHALL COMPLY WITH NEC 517.13(A)(B) TO INCLUDE LUMINAIRES. TELEPHONE OUTLET. WIRING BY OTHERS, UNO. MOUNT 18" AFF. WALL MOUNTED LIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. TELEPHONE OUTLET. WIRING BY OTHERS, UNO., WALL PHONE, MOUNT 48" AFF. W DATA OUTLET. WIRING BY OTHERS, UNO. MOUNT 18" AFF. RECESSED CEILING MOUNTED DOWNLIGHT, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. DATA/TELEPHONE OUTLET, WIRING BY OTHERS UNO. MOUNT 18" AFF. CABLE TV OUTLET, WIRING BY OTHERS, UNO. MOUNT 18" AFF. TV SURFACE MOUNTED CEILING DOWNLIGHT, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. T PENDANT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. TRACK HEAD FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. FIRE ALARM SYMBOLS UTILITY COORDINATION: PROVIDE ALL COORDINATION WITH THE UTILITY INCLUDING LOAD DATA FORMS AND APPLICATION FOR SERVICE AS APPLICABLE. INSTALLATION OF SERVICE, PRIMARY OR SECONDARY FEEDERS AND METERING SHALL BE PERFORMED IN ACCORDANCE WITH THE UTILITIY REQUIREMENTS. HORN ONLY THERMOSTAT. PROVIDED BY MECHANICAL., INSTALLED BY ELECTRICIAN. LINE VOLTAGE F HORN AND STROBE PARKING LOT POLE LIGHT, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. STROBE ONLY F MANUAL PULL STATION S SMOKE DETECTOR H HEAT DETECTOR S GROUNDING: PROVIDE A COMPLETE GROUNDING SYSTEM AS REQUIRED BY THE NEC AND LOCAL AUTHORITIES HAVING JURISDICTION. ALL BRANCH CIRCUITS SHALL INCLUDE A GROUND CONDUCTOR. USE OF RACEWAY FOR GROUNDING IS NOT PERMITTED. GALVANIZED GROUND RODS ARE NOT PERMITTED. PANELBOARDS: PROVIDE MINIMUM INTEGRATED EQUIPMENT SHORT CIRCUIT RATING AS INDICATED ON PANEL SCHEDULES. PROVIDE BOLT-ON BREAKERS UNLESS OTHERWISE NOTED. PROVIDE CIRCUIT BREAKERS SHOWN ON THE PANELBOARD SCHEDULES. ALL TERMINATIONS AND LUGS SHALL BE RATED FOR 75-DEGREE CONDUCTORS. PROVIDE TYPEWRITTEN CIRCUIT SCHEDULES TO IDENTIFY PANELBOARD AND EACH BRANCH BREAKER. ACCEPTABLE MANUFACTURERS ARE SQUARE D, SIEMENS AND EATON. DUCT SMOKE DETECTOR D MAGNETIC DOOR HOLD OPEN LIGHT FIXTURE WITH EMERGENECY BALLAST, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. FIRE/SMOKE DAMPER WIRING DEVICES: PROVIDE SPECIFICATION GRADE 15 AND 20- AMPERE SWITCH AND RECEPTACLE DEVICES, AS APPLICABLE. OTHER DEVICES SHALL BE PROVIDED AS INDICATED AND SHALL MATCH PLUG-CONNECTED EQUIPMENT FURNISHED FOR THE PROJECT. DEVICE WALL PLATES SHALL BE SMOOTH, NYLON TYPE AND SHALL BE OFFICE WHITE IN COLOR OR AS OTHERWISE SPECIFIED. DEVICE COLOR SHALL MATCH WALL PLATES. FIRE ALARM CONTROL PANEL EMERGECY LIGHT, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. ANNUNCIATION PANEL EXIT SIGN, WITH TYPE NOTED IN PLAN, SEE PLAN FOR ARROWS AND FACE OF EXIT NEEDED. SEE FIXTURE SCHEDULE FOR DETAILS. ONE-LINE SYMBOLS SWITCHES CIRCUIT BREAKER, FRAME AND TRIP AS INDICATED. TOGGLE SWITCH, 20A, SINGLE POLE, VOLTAGE AS REQUIRED. MOUNTED AT 48" ABOVE FINIDHED FLOOR. POWER TRANSFORMER, RATING AS INDICATED. DISCONNECT SWITCHES: HEAVY DUTY QUICK-MAKE, QUICK-BREAK TYPE, NON-FUSED UNLESS OTHERWISE NOTED. PROVIDE MEANS TO LOCK SWITCH IN OFF POSITION WITH PAD-LOCK. ENCLOSURES SHALL BE NEMA TYPE 1 OR NEMA TYPE 3R FOR OUTDOOR INSTALLATION. PROVIDE PERMANENT LABELS FOR DISCONNECTS TO INDICATE EQUIMENT SERVED. LIGHTING FIXTURES: SEE LIGHT FIXTURE SCHEDULE. PROVIDE ALL FIXTURES WITH LAMPS AS INDICATED. WHERE REQUIRED, FIXTURES SHALL BE WET OR DAMP LOCATION LABELED. VERIFY MOUNTING HEIGHTS PRIOR TO ELECTRICAL ROUGH-IN. PROVIDE ALL REQUIRED MOUNTING ACCESSORIES REQUIRED FOR PROPER MOUNTING TO SURFACES SUCH ACCESSORIES TO INCLUDE BUT NOT LIMITED TO SLOPE ADAPTORS. CANOPIES, AND VAULTED CEILING CANOPIES, ETC. PROVIDE DISCONNECTING MEANS FOR LUMINAIRES THAT UTILIZE DOUBLE-ENDED LAMPS AND BALLASTS(S) IN ACCORDANCE WITH NEC 410.130(G)(1). ALTERNATES NOT ACCEPTABLE UNLESS NOTED AS "OR EQUAL" ON LIGHT FIXTURE SCHEDULE. S OCCUPANCY SENSOR, WALL MTD., 48" AFF. SENSOR SWITCH WSD PDT, OR EQUAL OCCUPANCY SENSOR, CEILING MTD. SENSOR SWITCH CMR PDT OR EQUAL GROUND ELECTRODE PHOTOCELL SWITCH, MOUNT ON NORTH FACING EXTERIOR WALL, UNO. CURRENT TRANSFORMER (CT) VOICE/DATA: RACEWAY SYSTEM BY CONTRACTOR. ALL RACEWAYS SHALL BE PROVIDED WITH PULLSTRINGS OF MINIMUM OF 400-LB. TEST STRENGTH. ALL EQUIPMENT, RECEPTACLES AND CABLING BY OTHERS. PROVIDE BLANK COVERS OVER ALL UNUSED OUTLETS. CABLES, DEVICES AND CABLE TERMINATION IS BY OTHERS. SUBSCRIPTS FOR SWITCHES NON-FUSIBLE SWITCH, RATING AS INDICATED. 3 THREE-WAY TOGGLE SWITCH 4 FOUR-WAY TOGGLE SWITCH D 0 - 10 VOLT ELECTRONIC DIMMER SWITCH, 1000W, 120V LUTRON DIVA OR EQUAL, UNO. COORDINATE COMPATIBLE DIMMER WITH LIGHTING MANUFACTURER. M MANUAL MOTOR STARTER WITH THERMAL OVERLOAD FIRE ALARM: DESIGN BUILD CONTRACTOR TO PROVIDE AS REQUIRED PER FIRE AND LOCAL CODES. FUSIBLE SWITCH, RATING AND FUSE SIZE AS INDICATED. FEEDER SCHEDULE KEY TAG UTILITY TRANSFORMER RECEPTACLES UTILITY ELECTRIC METER M DUPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO., MOUNT 18" AFF. CRGA CR2A Chavez Tiffany & Ayers Engineering Corporation UPS2 119 West Cucharras Street Colorado Springs, Colorado 80903 P (719)636-0021 QUAD RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO., MOUNT 18" AFF. MOTOR WITH DISCONNECT SIMPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO. MOUNT 18" AFF. MCB SPECIAL RECEPTACLE, 220V, TYPE AS INDICATED OR MATCH EQUIPMENT CAP., MOUNT AT HEIGHT AS REQUIRED PER EQUIPMENT. MOTOR WITH CONTROLLER AND DISCONNECT DUPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO., WITH TIE-BAR REMOVED FOR SWITCHING., MOUNT 18" AFF. SPECIAL PURPOSE RECEPTACLE, NEMA TYPE AS INDICATED., MOUNT AT HEIGHT AS REQUIRED PER EQUIPMENT. FLOOR BOX DUPLEX RECEPTACLE, FLUSH MOUNTED, PROVIDE COVER AS REQUIRED. GENERATOR G FLOOR BOX QUAD RECEPTACLE, FLUSH MOUNTED, PROVIDE COVER AS REQUIRED. N S L TRANSFER SWITCH 15KVA 3PH 480V DELTA PRI. WEATHERHEAD 208Y/120V SEC SUBSCRIPTS FOR RECEPTACLES C CLOCK RECEPTACLE CE CEILING FLUSH MOUNTED IG ISOLATED GROUND GFI GROUND FAULT INTERRUPTER WR WEATHER RESISTANT WITH GROUND FAULT INTERRUPTER IN WEATHER PROOF BOX OC OVER COUNTER, MOUNT RECEPTACLE MOUNTED 6" ABOVE BACKSPLASH. UNO UNLESS NOTED OTHERWISE. UC UNDER COUNTER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR EWC ELECTRIC WATER COOLER, PROVIDE GFI PROTECTION E EXISTING DEVICE TO REMAIN. N NEW DEVICE TO BE INSTALLED H MOUNT DEVICE 6" AFF, HORIZONTALLY. TP TAMPER-PROOF SWD SWITCH RATED BREAKERS NL NIGHTLIGHT WIRED FIXTURE POWER SYMBOLS J J JUNCTION BOX, FLUSH/SURFACE MTD. POWER POLE WITH COMM AND POWER. 150AF 70AF 200A/3P 100A/3P ID PANELBOARD OR LOADCENTER, IDENTIFICATION, AMPERES AND VOLTAGE. ABBREVIATIONS TVSS CLGA CL1A UPS 45KVA 3PH 480V DELTA PRI. 208Y/120V SEC FEEDER SCHEDULE 5(4#400 CU IN 3" PVC) MAIN BREAKER GFI 225A/3P MOTOR 3#3 1#6 CU IN 1-1/2" EMT 30A/3P 100A/3P 100A/3P 70A/3P 40A/3P NON FUSIBLE DISCONNECT SWITCH, RATING AS INDICATED. 4#250 1#2 CU IN 2-1/2" EMT FUSIBLE DISCONNECT SWITCH, RATING AS INDICATED. 4#4/0 1#2 CU IN 2-1/2" EMT PANELBOARD/LOADCENTER. 3#1 1#6 CU IN 1-1/4" EMT CEILING MOUNTED PAD FAN. NOTE: NOT ALL SYMBOLS ARE USED. VERIFY ALL CONNECTIONS AND RECEPTACLE TYPES FOR EQUIPMENT EQUIPMENT FROM APPROVED MECHANICAL AND EQUIPMENT SUBMITTALS PRIOR TO INSTALLATION. RGA NOTES: 1. ALL ELECTRICAL EQUIPMENT, FEEDERS AND PANELBOARDS ARE EXISTING TO REMAIN UNLESS NOTED OTHER WISE. 2. PROVIDE NEW BREAKERS IN EXISTING PANELS AS NEEDED. CONTRACTOR TO VERIFY NUMBER AND SIZE OF NEEDED BREAKERS. 3. NEW ADDED BREAKERS TO HAVE AIC RATING MATING EXISTING. 4. CONTRACTOR SHALL VERIFY ALL BRANCH CIRCUITS AND PROVIDE TYPE WRITTEN UPDATED PANEL DIRECTORY FOR ALL PANELS. 5. SECOND FLOOR PANELS ARE CONNECTED WITH FEED THROUGH LUGS FROM FIRST FLOOR PANELS. R2A 5#10 CU IN 3/4" EMT GENERATOR MCB G MCB 2(4#4/0 1#2 CU IN 2-1/2" EMT) 4#3 1#6 CU IN 1-1/2" EMT R1A ELEVATOR 15KVA 3PH 480V DELTA PRI. GFI 225A/3P R1A1 M2A NOT USED MCB 3#6 1#6 CU IN 1" EMT 208Y/120V SEC 3#4 1#8 CU IN 1-1/4" EMT (4#3 1#6 EQUIPMENT GND AND 1#3 INSULATED/ISOLATED GND) IN 1-1/2" EMT TVSS LGA L N L1A M1A SM (4#1 1#6 EQUIPMENT GND AND 1#1 INSULATED/ISOLATED GND) IN 1-1/2" EMT 75KVA 3PH 480V DELTA PRI. SHUNT TRIP 70A/3P 4#2/0 1#4 CU IN 2-1/2" EMT 208Y/120V SEC ELECTRICAL LEGEND NOT USED 4#4 1#6 CU IN 1" EMT SERVICE MAIN 1600AS/3P PUBLIC SAFETY BUILDING - UCCS BOLLARD OR POST LIGHT, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. F MILITARY AND STUDENT VETERAN CENTER REMODEL SPOTLIGHT FIXTURE, WITH TYPE NOTED IN PLAN. SEE FIXTURE SCHEDULE FOR DETAILS. BID SET: 2/01/2016 3#8 1#8 CU IN 3/4" EMT 60A/3P 225A/3P 70A/3P 250A/3P 200A/3P 125A/3P 400A/3P 01/29/16 200A/3P 4#6 1#6 CU IN 1" EMT EXISTING PAD MOUNT TRANSFORMER EXISTING SERVICE GROUND EXISTING CT CABINET AND METER 1 EJR 3#3 1#6 CU IN 1-1/4" EMT JJA (4#2/0 1#4 EQUIPMENT GND AND 1#2/0 INSULATED/ISOLATED GND) IN 2" EMT 15135 ELECTRICAL ONE-LINE DIAGRAM E1.0 NONE 0' 1' 5' 10' 20' Chavez Tiffany & Ayers Engineering Corporation PUBLIC SAFETY BUILDING - UCCS MILITARY AND STUDENT VETERAN CENTER REMODEL 119 West Cucharras Street Colorado Springs, Colorado 80903 P (719)636-0021 ELECTRICAL SCHEDULES BID SET: 2/01/2016 01/29/16 EJR JJA 15135 E2.0 0' 1' 5' 10' 20' X 1. 2. 3. FLAG NOTES: REMOVE AND RELOCATE EXISTING FIXTURE. RE-LAMP AND RE-BALLAST FIXTURE AS NEEDED. REMOVE AND RELOCATE EXISTING EXIT SIGN. REMOVE AND RELOCATE EXISTING EXTERIOR WALL PACK. GENERAL NOTES: 1. 2. EXIST. MENS GRAY LIGHTWEIGHT ITEMS ARE EXISTING TO REMAIN. DARK DASHED ITEMS ARE TO BE DEMOLISHED. EXIST. WOMENS S F S S S F S S 1 S 4 2 S 1 S F ENTRY CORRIDOR S S 3 S S S 2 S F 3 3 PUBLIC SAFETY BUILDING - UCCS S J 119 West Cucharras Street Colorado Springs, Colorado 80903 P (719)636-0021 MILITARY AND STUDENT VETERAN CENTER REMODEL 3 Chavez Tiffany & Ayers Engineering Corporation S 1 S 3 GFI 1 S 1 ELECTRICAL DEMOLITION FLOOR PLAN BID SET: 2/01/2016 01/29/16 EJR JJA 15135 1 ELECTRICAL DEMOLITION FLOOR PLAN E3.0 1/4" = 1'-0" 0' 1' 5' 10' 20' X 1. 2. 3. 4. 5. 6. 7. C C C C C ALL LIGHTING AND SWITCHING IN THIS AREA IS EXISTING TO REMAIN. NEW LOCATION OF EXISTING FIXTURE TO BE REINSTALLED. CONNECT TO CIRCUIT SHOWN IN PLAN. NOT USED. CONNECT CORRIDOR LIGHTS TO EXISTING LIGHTING CIRCUIT. EXISTING EXIT SIGN TO BE RE-INSTALLED AND CONNECTED TO LIGHTING CIRCUIT SHOWN IN PLAN. NEW LOCATION OF EXISTING WALL PACK TO BE REINSTALLED. RECONNECT TO EXITING LIGHTING CIRCUIT. GROUND MOUNTED SPOT LIGHT TO BE LOCATED ON HILL BEHIND RETAINING WALL AND DIRECTED AT CANOPY. COORDINATE EXACT LOCATION AND INSTALLATION WITH GENERAL CONTRACTOR AND UCCS PROJECT MANAGER. EXIST. WOMENS SHARED OFFICE 1 C C S S3 C SHARED OFFICE 2 (R) 1 C (R) PRIVATE OFFICE 2 PRIVATE OFFICE 1 C (R) 2 ELECTRICAL ROOM (R) 2 2 2 Chavez Tiffany & Ayers Engineering Corporation L1A-5 C D D 119 West Cucharras Street Colorado Springs, Colorado 80903 P (719)636-0021 D MILITARY AND STUDENT VETERAN CENTER REMODEL D D A S 3 D A A A D A A STAFF SMALL MEETING D ENTRY CORRIDOR RECEPTION AE A AE A D D A MECHANICAL ROOM A LOUNGE 5 D D S S S S D D D D A D A S A D D A L1A-7 A A COMPUTERS REAR ENTRY VESTIBULE A A X A D D D D D D AE D 5 6 PUBLIC SAFETY BUILDING - UCCS EXIST. WOMENS EXIST. MENS C FLAG NOTES: L1A-13 7 NEW WORK LIGHTING PLAN G BID SET: 2/01/2016 01/29/16 EJR JJA 15135 1 NEW WORK LIGHTING PLAN E4.1 1/4" = 1'-0" 0' 1' 5' 10' 20' X 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. PROVIDE DEDICATED RECEPTACLE AND CIRCUIT FOR PRINTER. PROVIDE DEDICATED RECEPTACLE AND CIRCUIT FOR COPIER. PROVIDE JUNCTION BOX ABOVE CEILING FOR CONNECTION TO BUILT-IN DISPLAY CASE WITH LED PUCK LIGHTS. ELECTRICAL CONTRACTOR TO VERIFY POWER AND CONNECTION REQUIREMENTS PRIOR TO ROUGH-IN. PROVIDE GFI DEAD FRONT FOR REFRIGERATOR RECEPTACLE. GFI DEAD FRONT TO BE LOCATED IN ACCESSIBLE AREA TO COMPLY WITH NEC 210.8. ALL ELECTRICAL IN THIS AREA IS EXISTING TO REMAIN. PROVIDE PLUGMOLD WITH DUPLEX RECEPTACLE SPACED EVERY 12" OC. MOUNT PLUGMOLD 6" BELOW BOTTOM WINDOW SILL, FIELD VERIFY MOUNTING HEIGHT. EXISTING FIRE SMOKE DAMPER CONNECTED TO EXISTING DUCT WORK. ELECTRICAL CONTRACTOR TO VERIFY EXISTING ELECTRICAL CONNECTION. IF NEEDED CONNECT TO NEAREST 120V CIRCUIT. PROVIDE GFI DEAD FRONT FOR DISHWASHER RECEPTACLE. GFI DEAD FRONT TO BE LOCATED IN ACCESSIBLE AREA TO COMPLY WITH NEC 210.8. PROVIDE GFI DEAD FRONT FOR MICROWAVE RECEPTACLE. GFI DEAD FRONT TO BE LOCATED IN ACCESSIBLE AREA TO COMPLY WITH NEC 210.8. PROVIDE IN-CARPET WIREWAY BY CONNECTRAC FOR POWER AND TELECOM CONNECTIVITY. ROUTE FROM WALL TO DEAD END UNDER RECEPTION DESK. PROVIDE (2) DUPLEX RECEPTACLES AND 2-PORT TELECOMM DEVICE, TO BE CLEAR ANODIZED ALUMINUM FINISH. COORDINATE INSTALLATION WITH CARPET INSTALL. EXISTING ELECTRICAL EQUIPMENT TO REMAIN, NO NEW WORK. FOR REFERENCE ONLY. DATA OUTLET - CONTRACTOR TO PROVIDE 1" MIN. CONDUIT AND PULL STRING ABOVE ACCESSIBLE CEILING EXIST. WOMENS 5 SHARED OFFICE 1 SHARED OFFICE 2 5 PRIVATE OFFICE 1 5 PRIVATE OFFICE 2 7 ELEC. CLOS. EXIST. MENS FLAG NOTES: ELECTRICAL ROOM 11 OC OC F 4 GFI /OC R1A1-52 R1A1-54 GFI/OC Chavez Tiffany & Ayers Engineering Corporation 7 119 West Cucharras Street Colorado Springs, Colorado 80903 P (719)636-0021 GFI R1A1-64 MILITARY AND STUDENT VETERAN CENTER REMODEL STAFF KIT. 72" 46 72" R1A1-62 J 3 2 OC R1A1-56 7 7 STAFF SMALL MEETING 7 72" ENTRY CORRIDOR R1A1-49 TV J RECEPTION R1A1-45 72" MECHANICAL ROOM 72" 10 R1A1-60 3 COMPUTERS J R1A1-58 4 72" 7 GFI /OC 7 1 7 LOUNGE 45 72" R1A1-66 8 R1A1-70,72,74 R1A1-51 R1A1-53 R1A1-43 6 9 REAR ENTRY VESTIBULE R1A1-68 S GFI /OC ECUH-1 J F PUBLIC SAFETY BUILDING - UCCS R1A1-48 NEW WORK POWER PLAN BID SET: 2/01/2016 01/29/16 EJR JJA 15135 1 NEW WORK POWER PLAN E4.2 1/4" = 1'-0" 0' 1' 5' 10' 20' S N O I S I V E R EXIST. MENS EXIST. WOMENS STG-1 STG-1 ELEC. CLOS. VF 1 VF 2 VF 3 SHARED OFFICE 1 VF 4 1D (N) STG-1 STG-1 EXIST. QTY. 4 EXIST. 1D (N) REMOVE SURFACE MTD. PATCH CORD STG-1 2D 1V(E) ELECTRICAL ROOM EXIST. 2D (E) 2D 1V(E) 2D 1V (E) 2D 1V(E) EXIST. EXIST. ︶ PRIVATE OFFICE 1 EXIST. 2D (N) SHARED OFFICE 2 MODIFY ANALOG LINE EXIST. STG-1 PRIVATE OFFICE 2 DESK-2 DESK-3 EXIST. ︵ ︵ EXIST. STG-1 EXIST. EXIST. 4 STACK EXIST. ︶ 3D (N) EXIST. R O F E T A D 3 1 1 e t i u S 3 , t e0 9 e r t0 S8 e sO n x aC o a m, h PF s i ng An 3 r1 si 44 ap 6 LS 6 5 5 t . o sd 33 aa 22 Er 66 9. 9 1o l. 0o 11 2C 77 EXIST. EXIST. EXIST. EXIST. DESK-3 MOP SINK EXIST. STAND UP STATION FLAT WIRE BROCHURE HOLDER STG-5 STG-4 1D (E) STG-1 STG-2 ENTRY CORRIDOR ER PI CO STG-5A BROCHURE HOLDER1D(E) STG-2 STG-5A 1D(E) RELOCATED FROM RECEPTION 4D/2V 2D (E) STG-4 TBL-4 STG-4 DESK-3 2D (EXIST) STG-1 1D(N) RECEPTION STG-5 EXIST. TO REMAIN STG-4 STG-4 COMPUTERS STG-4 WAP (N) 2D(N) STG-5A 2D (EXIST. TO RELOCATE) TBL-3 STG-3 STG-3 STG-3 STG-3 STG-3 STG-3 TBL-3 TBL-1 WIRING/CABLING TO RUN FROM CEILING INTO THE WALL AND RUN HORIZONTAL EXISTING = 27D/13V REUSE = 23D NEW = 17D DATA OUTLET - CONTRACTOR TO PROVIDE 1" MIN. CONDUIT AND PULL STRING ABOVE ACCESSIBLE CEILING EXISTING 1/4" = 1'-0" 2D (N) STG-4, QTY. 6 STG-4 STG-5 2D (EXIST. TO RELOCATE) 1 1D (N) TBL-2 GFI ADD 1D FOR PHONE STG-4 STG-4 REF. GFI MAIN LEVEL TECHNOLOGY PLAN 1D (E) STG-5A LOUNGE STG-5A STG-4 REUSE EXISTING 2D/1V (RM 118) REUSE EXIST 2D/1V TBL-4 ADD (1) DUPLEX POWER & 1D(N) FOR FUTURE MESSAGE TV PANEL STAFF SMALL MEETING STG-4 TBL-2 NEW COAX STG-5 GFI STAFF KIT. DESK-3 STG-2 WAP (EXIST) REUSE 1D(E) NEW OR EXISTING TO BE RELOCATED SMALL GROUP MTG. ELECTRICAL ROOM PUBLIC SAFETY BUILDING EXIST. 1D (NEW) KEEP ANALOG LINE (FAX) DESK-1 NEW CORR. ENTRY 2D (E)EXIST. GFI REF. ADD (1) DUPLEX POWER & 1D(N) FOR FUTURE MESSAGE TV PANEL RELOCATED MILITARY AND STUDENT VETERAN CENTER REMODEL STG-1 WALL MOUNT TV STG-1 MAIN LEVEL FURNITURE REFERENCE PLAN Project Status : E T A D DATE: 12/30/2015 : Y B N W A R D KH, AR : Y B D E K C E H C Checker : . O N T C E J O R P 15135 : T E E H S ID-1.1