Original Equipment Manufacturer (OEM): Turbine Machine No.: Year of manufacture: 1985

advertisement
Data Record for Used Industrial Steam Turbines / Turbosets
Turbine
Original Equipment Manufacturer (OEM):
AEG Kanis GmbH Nürnberg
Turbine model: VE40
Machine No.: 18914/000
Year of manufacture: 1985
Design output (MW)
[at best turbine efficiency]: 12890 kW (klemme)
Maximum output (MW): 12890 kW(klemme)
Steam consumption at design output (kg/kWh): 6,129
Steam consumption at max. output (kg/kWh): 6,129
1)
_
o
Max. main steam temperature (°C) : 300 C
Main steam pressure (bar g)1):
norm 48 bar g (max 51 bar g)
Exhaust steam temperature (°C)1): 105oC
Main steam temperature (°C)1): 262,7oC
Exhaust steam pressure (bar): 0.044 - 0.14 bar abs
Extraction pressure (bar abs)2): 5,88 and 1.18
Main steam flow (t/h)1): 79-93 t/h, max 93,6 t/h
Exhaust steam flow (t/h)1): 69.59 t/h
Extraction flow (t/h)2): I extr – 0-51,8t/h, II extr- 0- 14,8 t/h
Speed (rpm): 7568 rpm (turbine)
Direction of rotation:
Allowable frequency range (Hz): 50 Hz
to left (view from turbine to generator)
Exhaust steam nozzle (downward, upward, right, left or axial): downward
Non-drive end of turbine (HP/LP end):
Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): by request
In case of package, is integral lube oil system provided? (yes/no): yes
or extract from Operating Manual
Load points
Main steam flow (kg/s)
1
49,03 bar abs
262,7oC
25,558 kg/s
2
49,03 bar abs
262,7oC
25,836 kg/s
3
49,03 bar abs
262,7oC
21,944 kg/s
4
49,03 bar abs
262,7oC
14,486 kg/s
Extraction I pressure (bar)
Extraction I flow (kg/s)
Extraction II pressure (bar)
Extraction II flow (kg/s)
Exh. steam pressure (bar)
5,88 bar abs
14,389 kg/s
1,18 bar abs
3,889 kg/s
0,053 bar abs
5,88 bar abs
10,778 kg/s
1,18 bar abs
4,111 kg/s
0,067 bar abs
5,88 bar abs
1,18 bar abs
0,14 bar abs
5,88 bar abs
6,667 kg/s
1,18 bar abs
2,778 kg/s
0,044 bar abs
Exh. steam temp. (°C)1)
n.a.
n.a.
n.a.
n.a.
Terminal output (kW)
8950
10655
12890
4140
Main steam parameters
Turbine condition: not preservated
Last minor overhaul: no
Last major overhaul: no
Operating hours: 70 hours
Date of turbine shutdown and preservation details:
1988, any special preservation, saved inside in building since installing according the design
Expected to be available as from: 8.06.2015
Siemens AG
Energy Sector; Management: Lisa Davis
Energy Service Division; Management: Randy Zwirn
Oil & Gas and Industrial Applications Services; Management: Willibald Meixner
Frankenstr. 70-80
90461 Nuernberg
Germany
Tel.: +49 (911) 4130 0
Fax: +49 (911) 4130 440
Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme;
Managing Board: Joe Kaeser, Chairman, President and Chief Executive Officer; Roland Busch, Lisa Davis, Klaus Helmrich,
Hermann Requardt, Siegfried Russwurm, Ralf P. Thomas
Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684
WEEE-Reg.-No. DE 23691322
SCF 08/2014 V13.06
1) in accordance with turbine design
2) where applicable
Are spare parts available? If yes, which ones? - n.a.
Turbine control and protection system
Original Equipment Manufacturer (OEM):
Hydraulic or electronic: hydraulic
Overspeed protection system (hydraulic [bolt]/electronic): hydraulic
Axial shaft position monitoring system (hydraulic [nozzle]/electronic): hydraulic
Vibration monitoring system (yes/no): yes
Actuators for control and stop valve(s) (HP/LP hydraulic system): LP hydraulic system
Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth):
Electrohydraulic converter installed (yes/no): yes, reductor type TRE63, Graffenstaden
Condenser: n.a.
Original Equipment Manufacturer (OEM): -
Condenser model: -
Condensing capacity (t/h): -
Condenser pressure (bar): -
Cooling water flow (m 3/h): -
Cooling water velocity (m/s): -
Cooling water inlet temperature (°C): -
Thermal capacity (MW): -
Supply lines: Complete operating documentation available (yes/no): yes
Complete machine file available (yes/no): yes
Is the driven machine also available for purchase (yes/no): n.a.
SCF 08/2014 V13.06
Driven generator: DKBL 908/04
Machine No.:
Original Equipment Manufacturer (OEM): AEG/LDW
Generator type (cooling system):
self-separ.air/water cooling
Rating (MVA): 16120
Voltage (kV): 6,3 kV
Frequency (Hz): 50
Current (A): 1477 A
Power factor (cos phi): 0.8 S1
Speed (rpm): 1500
Design: brushless synchronous 4-poles
Insulation class: IP44
Type of enclosure: GEA Type 250/645/42
Cooling water inlet temperature (°C):
Cooling water flow (m 3/h):
Generator model: IM 7215
Compound excitation (130 V - 10 A): DEA 2340
Generator condition: good
Last minor overhaul: no
Last major overhaul: no
Operating hours: 72 hours
Date of turbine shutdown and preservation details: without preservation
Expected to be available as from: 8.06.2015
Gear unit: yes
Original Equipment Manufacturer (OEM): Graffenstaden
Gear unit model: TRE63
Rating (HP) 7568/1500
Speed (rpm):
Complete scope of supply available for purchase:
·
Steam Turbine
·
Reductor
·
Generator
·
·
·
·
·
·
Size (footprint) / dimensions:
Please provide photographs of the turboset / turbine separately in electronic form.
SCF 08/2014 V13.06
Download