Data Record for Used Industrial Steam Turbines / Turbosets Turbine Original Equipment Manufacturer (OEM): AEG Kanis GmbH Nürnberg Turbine model: VE40 Machine No.: 18914/000 Year of manufacture: 1985 Design output (MW) [at best turbine efficiency]: 12890 kW (klemme) Maximum output (MW): 12890 kW(klemme) Steam consumption at design output (kg/kWh): 6,129 Steam consumption at max. output (kg/kWh): 6,129 1) _ o Max. main steam temperature (°C) : 300 C Main steam pressure (bar g)1): norm 48 bar g (max 51 bar g) Exhaust steam temperature (°C)1): 105oC Main steam temperature (°C)1): 262,7oC Exhaust steam pressure (bar): 0.044 - 0.14 bar abs Extraction pressure (bar abs)2): 5,88 and 1.18 Main steam flow (t/h)1): 79-93 t/h, max 93,6 t/h Exhaust steam flow (t/h)1): 69.59 t/h Extraction flow (t/h)2): I extr – 0-51,8t/h, II extr- 0- 14,8 t/h Speed (rpm): 7568 rpm (turbine) Direction of rotation: Allowable frequency range (Hz): 50 Hz to left (view from turbine to generator) Exhaust steam nozzle (downward, upward, right, left or axial): downward Non-drive end of turbine (HP/LP end): Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): by request In case of package, is integral lube oil system provided? (yes/no): yes or extract from Operating Manual Load points Main steam flow (kg/s) 1 49,03 bar abs 262,7oC 25,558 kg/s 2 49,03 bar abs 262,7oC 25,836 kg/s 3 49,03 bar abs 262,7oC 21,944 kg/s 4 49,03 bar abs 262,7oC 14,486 kg/s Extraction I pressure (bar) Extraction I flow (kg/s) Extraction II pressure (bar) Extraction II flow (kg/s) Exh. steam pressure (bar) 5,88 bar abs 14,389 kg/s 1,18 bar abs 3,889 kg/s 0,053 bar abs 5,88 bar abs 10,778 kg/s 1,18 bar abs 4,111 kg/s 0,067 bar abs 5,88 bar abs 1,18 bar abs 0,14 bar abs 5,88 bar abs 6,667 kg/s 1,18 bar abs 2,778 kg/s 0,044 bar abs Exh. steam temp. (°C)1) n.a. n.a. n.a. n.a. Terminal output (kW) 8950 10655 12890 4140 Main steam parameters Turbine condition: not preservated Last minor overhaul: no Last major overhaul: no Operating hours: 70 hours Date of turbine shutdown and preservation details: 1988, any special preservation, saved inside in building since installing according the design Expected to be available as from: 8.06.2015 Siemens AG Energy Sector; Management: Lisa Davis Energy Service Division; Management: Randy Zwirn Oil & Gas and Industrial Applications Services; Management: Willibald Meixner Frankenstr. 70-80 90461 Nuernberg Germany Tel.: +49 (911) 4130 0 Fax: +49 (911) 4130 440 Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Joe Kaeser, Chairman, President and Chief Executive Officer; Roland Busch, Lisa Davis, Klaus Helmrich, Hermann Requardt, Siegfried Russwurm, Ralf P. Thomas Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE 23691322 SCF 08/2014 V13.06 1) in accordance with turbine design 2) where applicable Are spare parts available? If yes, which ones? - n.a. Turbine control and protection system Original Equipment Manufacturer (OEM): Hydraulic or electronic: hydraulic Overspeed protection system (hydraulic [bolt]/electronic): hydraulic Axial shaft position monitoring system (hydraulic [nozzle]/electronic): hydraulic Vibration monitoring system (yes/no): yes Actuators for control and stop valve(s) (HP/LP hydraulic system): LP hydraulic system Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): Electrohydraulic converter installed (yes/no): yes, reductor type TRE63, Graffenstaden Condenser: n.a. Original Equipment Manufacturer (OEM): - Condenser model: - Condensing capacity (t/h): - Condenser pressure (bar): - Cooling water flow (m 3/h): - Cooling water velocity (m/s): - Cooling water inlet temperature (°C): - Thermal capacity (MW): - Supply lines: Complete operating documentation available (yes/no): yes Complete machine file available (yes/no): yes Is the driven machine also available for purchase (yes/no): n.a. SCF 08/2014 V13.06 Driven generator: DKBL 908/04 Machine No.: Original Equipment Manufacturer (OEM): AEG/LDW Generator type (cooling system): self-separ.air/water cooling Rating (MVA): 16120 Voltage (kV): 6,3 kV Frequency (Hz): 50 Current (A): 1477 A Power factor (cos phi): 0.8 S1 Speed (rpm): 1500 Design: brushless synchronous 4-poles Insulation class: IP44 Type of enclosure: GEA Type 250/645/42 Cooling water inlet temperature (°C): Cooling water flow (m 3/h): Generator model: IM 7215 Compound excitation (130 V - 10 A): DEA 2340 Generator condition: good Last minor overhaul: no Last major overhaul: no Operating hours: 72 hours Date of turbine shutdown and preservation details: without preservation Expected to be available as from: 8.06.2015 Gear unit: yes Original Equipment Manufacturer (OEM): Graffenstaden Gear unit model: TRE63 Rating (HP) 7568/1500 Speed (rpm): Complete scope of supply available for purchase: · Steam Turbine · Reductor · Generator · · · · · · Size (footprint) / dimensions: Please provide photographs of the turboset / turbine separately in electronic form. SCF 08/2014 V13.06