Avtron IHT Intelligent Hand-Held Terminal Fast and Accurate Testing with Maximum Efficiency. Key Features •Remote Operation with full 3-Phase Instrumentation •Network Capability for Control of Multiple Load Banks •Modbus Interface Provides Integration with PLC, HMI, or SCADA Systems An Avtron Load Bank with Intelligent Hand-Held Terminal (IHT) Sigma™ load control and instrumentation is the leader in simplicity, ease of use, and accuracy. The Sigma 2 brings a powerful, yet cost effective solution to today’s power testing requirements. It provides high level instrumentation, data capture, and verification. The Sigma 2 load bank module is installed in the load bank with Voltage and Current Transformers (VTs and CTs). It is the control interface for all the functions within the load bank. • Robust Purpose Designed Microprocessor-Based Module with Industrial Connectors and LED Status Display • Usage Counters provide Information on Individual Contactor Operation, Element Run Times, Overall Power-on Time, Load-on Time, and KWH • 24 VDC Supply Voltage with 24 VDC Input and Outputs •Rugged and Lightweight Design with Sealed Membrane Controls includes a 30 ft. [10 meter] Interconnect Cable • Large Flash Memory allows Remote Upgrading and Space for Configuration Data and Calibration Maps Superior Avtron quality combined with simple operation and maintenance will provide years of trouble free service. • Automatic Detection Senses the Supply-On-Test Voltage, Frequency, Phase, and Phase Rotation Avtron’s extensive line of Load Bank and Industrial Resis­tor Products are solid performers used throughout the world. • Element On-Time Balancing provides for Enhanced Element Life and Insulation Resistance • Load Monitoring Checks each Phase for Faulty Contactors, Blown Fuses, or Faulty Elements. Faults are Logged with Visual Indication via Blinking Stop Lamp and Warning Code • Load Correction Facility compensates for any Voltage Drop on Supply • Load Bank is protected against Over-Voltage • Load Bank Cooling Fan automatically Starts and Stops as required For total technical support or additional information, please contact Avtron at (216) 573-7600 or LBsales@Emerson.com. Quality System Certified to ISO 9001 Avtron Intelligent Hand-Held Terminal (IHT) Avtron IHT Intelligent Hand-Held Terminal IHT Hardware The IHT provides full load control and 3-Phase instrumentation. The IHT provides enhanced load control and instrumentation. • Robust Hand-Held Terminal Housed in Industrial Polycarbonate/Polyamide Enclosure with PVC Hand Grips providing IP65 Protection • Operation and Data Capture • All instrumentation measurements are made using high accuracy voltage and current transformers located within the load bank. This information is processed digitally, using high speed sampling of the raw data. This provides full 3-phase, high speed, true RMS measurements with high updates rates to class 0.5 accuracy. • Display Pages Show All the Main Electrical Parameters • Calculation of rated line current and kilowatts • The Displays are designed to Simplify the Testing, Setup, and Adjustment of GenSets and UPS Systems • No need for any pre-calculations • Membrane Keyboard and Back-Lit Graphic LCD • Large Display of Voltage and Frequency Assist with Initial Set-up • Comprehensive overload and stall protection is provided, based on the rating of the supply-on-test. • Performs transient load tests • Automated load control provides multiple timed load steps including manual override and cyclic testing • In-built test editors allow easy set up of load including percent load, power factor, and time. • Manual control via selection of kW, percent load, or kVA. • Simple plug/socket connections allow multiple Avtron Load Banks of differing capacities and combination: resistive, inductive, or combined may be connected and controlled from one Intelligent Hand-Held Terminal (IHT) or PC (with optional software). • Operation up to a 3,280' from load bank. • Multilingual user interfaces include English, French, German, Spanish, and Italian. Weight & Dimensions (approx.) 3.75 lbs. [1.70 kg.] 9.31 x 7.50 [236.47 x 190.50] including lugs: 9.31 x 8.25 [236.47 x 209.55] Options When carrying out full-load testing, one page shows all the true RMS 3-Phase measurements of voltage (V), frequency (Hz), current (A), power (both KW and KVA), and power factor (Cos Ø). For transient-response testing, the voltage and frequency of the last load change are captured and displayed on the dynamic graph including maximum and minimum data. • Site Load Correction (SLC) Automatically Prevents Problems Associated with Light Loading • SIGMA™ PC Load Control Software Specifications are subject to change without notice. All dimensions are in inches [millimeters]. Load selection is displayed in a “popup” window over the instrumentation while the load is being changed. The status line includes the elapsed time since the last load was applied. Emerson Network Power Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A. 216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com EmersonNetworkPower.com/loadbank Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. All the other marks are the property of their respective owners. SIGMA™ is a trademark of NJ Froment & Co. Ltd. Specifications subject to change without notice. ©2015 Emerson Network Power Bulletin 602• Rev. B