Intelligent Hand-Held Terminal (IHT) Remote Operation with full 3-Phase Instrumentation Modbus Interface Provides Integration with PLC, HMI, or SCADA Systems Rugged and Lightweight Design with Sealed Membrane Controls includes a 30 ft. [10 meter] Interconnect Cable An Avtron load bank with Froment Intelligent HandHeld Terminal (IHT) Sigma™ load control and instrumentation is the leader in simplicity, ease of use, and accuracy. The Sigma 2 brings a powerful, yet cost effective solution to today’s power testing requirements. It provides high level instrumentation, data capture, and verification. The Sigma 2 load bank module is installed in the load bank with Voltage and Current Transformers (VTs and CTs). It is the control interface for all the functions within the load bank. • Robust Purpose Designed Microprocessor-Based Module with Industrial Connectors and LED Status Display • Usage Counters provide Information on Individual Contactor Operation, Element Run Times, Overall Power-on Time, Load-on Time, and KWH • Large Flash Memory allows Remote Upgrading and Space for Configuration Data and Calibration Maps • Non-Volatile RAM provides 500 Event History Log Time Stamped by On-Board Real Time Clock • Element On-Time Balancing provides for Enhanced Element Life and Insulation Resistance Fast and Accurate Testing with Maximum Efficiency • Load Correction Facility compensates for any Voltage Drop on Supply • Load Bank is protected against OverVoltage • Load Bank Cooling Fan automatically Starts and Stops as required Legendary quality combined with simple operation and maintenance will provide years of trouble free service. • Load Monitoring Checks each Phase for Faulty Contactors, Blown Fuses, or Faulty Elements. Faults are Logged with Visual Indication via Blinking Stop Lamp and Warning Code Avtron’s extensive line of Load Bank and Industrial Resis­tor Products are solid performers used throughout the world. • Automatic Detection Senses the SupplyOn-Test Voltage, Frequency, Phase, and Phase Rotation For total technical support or additional information, please contact Avtron at (216) 573-7600 or LBsales@emerson.com. • 24 VDC Supply Voltage with 24 VDC Input and Outputs power test solutions Intelligent Hand-Held Terminal (IHT) IHT HARDWARE: The IHT provides full load control and 3-Phase instrumentation. The IHT provides enhanced load control and instrumentation. • Robust Hand-Held Terminal Housed in Industrial Polycarbonate/Polyamide Enclosure with PVC Hand Grips providing IP65 Protection • All instrumentation measurements are made using high accuracy voltage and current transformers located within the load bank. This information is processed digitally, using high speed sampling of the raw data. This provides full 3-phase, high speed, true RMS measurements with high updates rates to class 0.5 accuracy. • Membrane Keyboard and Back-Lit Graphic LCD • Operation and Data Capture • Display Pages Show All the Main Electrical Parameters • The Displays are designed to Simplify the Testing, Setup, and Adjustment of Gen-Sets and UPS Systems • Large Display of Voltage and Frequency Assist with Initial Set-up SPECIFICATIONS: WEIGHT: 3.75 lbs [1.70 kg] DIMENSIONS: 9.31 x 7.50 [236.47 x 190.50] including lugs: 9.31 x 8.25 [236.47 x 209.55] OPTIONS: • Site Load Correction (SLC) Automatically Prevents Problems Associated with Light Loading • SIGMA PC Software • Calculation of rated line current and kilowatts When carrying out full-load testing, one page shows all the true RMS 3-Phase measurements of voltage (V), frequency (Hz), current (A), power (both KW and KVA), and power factor (Cos Ø). • No need for any pre-calculations • Comprehensive overload and stall protection is provided, based on the rating of the supply-on-test. • Performs transient load tests • Automated load control provides multiple timed load steps including manual override and cyclic testing • In-built test editors allow easy set up of load including percent load, power factor, and time. For transient-response testing, the voltage and frequency of the last load change are captured and displayed on the dynamic graph including maximum and minimum data. • Manual control via selection of kW, percent load, or kVA. • Simple plug/socket connections allow multiple Avtron Load Banks of differing capacities and combination: resistive, inductive, or combined may be connected and controlled from one Intelligent Hand-Held Terminal (IHT) or PC (with optional software). • Operation up to a 3,280’ from load bank. The status line includes the elapsed time since the last load was applied. • Multilingual user interfaces include English, French, German, Spanish, and Italian. Load selection is displayed in a “popup” window over the instrumentation while the load is being changed. SIGMA™ is a trademark of NJ Froment & Co. Ltd., Easton on the Hill, Stamford UK PE9 3NP All dimensions are in inches [millimeters]. Specifications subject to change without notice. Quality System Certified to ISO 9001 6255 Halle Drive • Cleveland, Ohio, U.S.A. 44125-4615 • 216.573.7600 • FAX 216.573.5953 www.avtronloadbank.com • LBsales@emerson.com Bulletin ev.-