What’s Cool in the Data Center

Thermal Management Innovations

Liebert

®

Direct Expansion

Air Handlers

MORE EFFICIENCY. MORE CHOICES. MORE EXPERIENCE.

Custom, Precision Air Handling Units

Our mission-critical air handlers with Liebert iCOM™ controls deliver effi cient, reliable and cost-effective management of heat in large data centers.

We offer the largest selection of air handling solutions, combined with the expert guidance to help you select, implement and maintain the right technology to ensure delivered performance for the lifetime of your data center.

Liebert Direct Expansion Air Handlers

Liebert Direct Expansion Air Handler Unit offerings deliver highly-effi cient thermal management with the fl exibility for modular data center build outs.

Higher Efficiency Designs.

Take advantage of multiple available confi gurations that include outside air economizers, evaporative condensing and evaporative cooling to reduce energy consumption and increase effi ciency. Full component redundancy within a single unit can ensure availability and avoid unplanned downtime or accidental damage.

Intelligent Controls.

The Liebert Direct Expansion Air Handler features integrated Liebert iCOM unit controls to maximize data center protection, effi ciency and insight. Its advanced controls prevent over-cooling and under-cooling by self-optimizing thermal system operations using machineto-machine communications and advanced algorithms.Teamwork modes harmonize the multiple cooling units for higher effi ciency and protection.

Local Service and Support . All of our solutions are backed by local customer engineers with decades of data center experience and a network of factory-trained service technicians.

Key Attributes

Easily accomodates modular build outs

Evaporative condensing with outside air can result in very effi ciency systems

Typical Deployments

Roof mounted units in single or two story buildings

Often requires supply and/or return ductwork for air distribution

Highly Efficient

Mechanical PUE less than 1.3

Variable speed fans, drives and compressors for lower energy usage

Evaporative condensing or outside air economization

Self-optimizing controls reduce over-cooling and under-cooling

Greater Protection

Less risk of hot spots, through advanced controls and rack inlet sensors

Advanced monitoring and event notifi cation

Finely tuned controls for more consistent unit supply air temperature and minimized swings across component ranges

Lower Installation & Maintenance Costs

Flexible deployment options enable external installation for space-restricted environments

Controls require little if any customization

Insight for Action

Simplifi ed access to real-time data and trending

Faster and easier system diagnostics

What’s Cool in the Data Center

Thermal Management Innovations

Liebert

®

Direct Expansion Air Handlers

Advanced Controls For Efficiency, Protection and Insight

Unit Control Strategies

Unit capacity controlled to supply air setpoint

Unit controlling economizer based on supply temp and enthalpy

Fan speed controlled by pressure setpoint in space or supply plenum

System Control Strategies

Rack inlet sensors used to verify fan airfl ow volume

Coordinate units for standby operation to prevent fi ghting

Return air pressure monitored for proper space pressure control

Exhaust

Hood

Filters

Supply Fan

Digital Scroll

Compressors

Dampers

Dampers

Section

Liebert Direct Expansion Air Handlers offer a complete data center cooling system in a single package that requires no space within the building. The unit components are selected for high effi ciency for today’s data center designs and rigorous 24/7 data center where down time is not an option. Liebert iCOM™ control algorithms continuously process readings from the rack inlet sensors to ensure optimal air fl ow through the system while supply air sensors are used to control the unit cooling capacity. Dampers or exhaust fans are automatically adjusted by the Liebert iCOM unit control, which also harmonizes the operation of multiple air handling units to eliminate confl icts in temperature, airfl ow, and humidity.

Emerson Network Power

Global Headquarters

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. & Canada Only)

614 888 0246 Phone (Outside U.S.)

Contact@EmersonNetworkPower.com

EmersonNetworkPower.com

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

© 2015 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert is a registered trademark of the Liebert Corporation. Avocent is a trademark of Avocent Corporation. Emerson, Consider it Solved, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.

©2015 Emerson Electric Co

SL-19713 (06/15) Printed in USA

Download