Liebert Chilled Water Air Handler MORE EFFICIENCY. MORE CHOICES. MORE EXPERIENCE.

advertisement
What’s Cool in the Data Center
Thermal Management Innovations
Liebert® Chilled Water
Air Handler
MORE EFFICIENCY. MORE CHOICES. MORE EXPERIENCE.
Highly Efficient
Liebert Custom Air Handling Units
Mechanical PUE less than 1.2 as part of a system
Our mission-critical air handlers with Liebert iCOM™ controls deliver efficient,
reliable and cost-effective management of heat in large data centers.
Multiple economization options available
We offer the largest selection of air handling solutions, combined with the expert
guidance to help you select, implement and maintain the right technology to ensure
delivered performance for the lifetime of your data center.
Self-optimizing controls reduce over-cooling and
under-cooling
Liebert Chilled Water Air Handler
The Liebert Chilled Water Air Handler Unit is the industry’s most advanced
chilled water cooling system, providing you with maximum thermal control in
your data center.
Economical Deployment. It maintains conditions at a wide range of return air
temperatures and is easy to commission and service, helping to boost productivity
and reduce installation and maintenance costs.
Industry-Leading Efficiency. The Liebert Chilled Water Air Handler Unit can deliver
higher-than-average temperatures (65-70°F), with industry-leading efficiency
through the use of for water- or air-side economization and high-efficiency EC fans.
Simplified Maintenance. Maintenance can be performed easily and quickly, as a
result of features such as full-coil cleaning access, front access to V-Bank filters and
single side-piping.
Intelligent Controls. The Liebert Chilled Water Air Handling Unit features
integrated Liebert iCOM unit controls to maximize data center protection,
efficiency and insight. The controls prevent over-cooling and under-cooling through
machine-to-machine communications and advanced algorithms. Teamwork modes
harmonize the multiple cooling units for higher efficiency and protection.
Local Service and Support. All of our solutions are backed by local customer
engineers with decades of data center experience and a network of factory-trained
service technicians.
Key Attributes
Very efficient with elevated water loop temperatures and waterside or
airside economizers
Indoor units are typically easy to service and commission
Typical Deployments
Vertical units along perimeter or in gallery discharging into raised floor
Horizontal units in gallery or outside the building — may not use raised floor
for air distribution
Use of EC fans for lower motor power usage
Greater Protection
Less risk of hot spots, through advanced controls and rack
inlet sensors
Advanced monitoring and event notification
Finely tuned controls for more consistent unit supply
air temperature and minimized swings across
component ranges
Lower Installation & Maintenance Costs
Multiple section design minimizes shipping costs and
speeds installation
Full coil cleaning access and single-side piping
Insight for Action
Simplified access to real-time data and trending
Quick diagnostics of potential critical events
What’s Cool in the Data Center
Thermal Management Innovations
Liebert® Chilled Water Air Handler
Advanced Controls For Efficiency, Protection and Insight
Filter Gauges
Return Air
Temperature
Sensors
Supply Air
Temperature
Sensors
Airflow Measurement
Meters
Fluid Flow
Sensors
Fan Power Meters
Liebert Chilled Water Air Handlers are best used with Liebert iCOM™
unit controls, wired or wireless rack sensors, and a Liebert iCOM-S™
system control to ensure that the entire data center system is optimized
with the other components of the chilled water system. Liebert iCOM
control algorithms continuously process readings from the rack inlet
sensors to ensure optimal air flow through the system while supply
Emerson Network Power
Global Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
air sensors are used to control the unit cooling capacity. Dampers
or exhaust fans are automatically adjusted by the Liebert iCOM unit
control, which also harmonizes the operation of multiple air handling
units to eliminate conflicts in temperature, airflow, and humidity.
800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
Contact@EmersonNetworkPower.com
EmersonNetworkPower.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or
omissions. © 2015 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert is a registered
trademark of the Liebert Corporation. Avocent is a trademark of Avocent Corporation. Emerson, Consider it Solved, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2015
Emerson Electric Co.
SL-19712 (06/15) Printed in USA
Download