AC Power For Business-Critical Continuity™ Liebert® NXL™ Power-Tie Controls Installation Manual CONTACTING EMERSON NETWORK POWER FOR SUPPORT Contact Emerson Network Power Liebert Services for information or repair service in the United States at 1-800-LIEBERT (1-800-543-2378). For repair or maintenance service outside the 48 contiguous United States, contact Liebert Services, if available in your area. For areas not covered by Liebert Services, the authorized distributor is responsible for providing qualified, factory-authorized service. Have the following information available before calling Liebert Services: Part Numbers: ________________________________________________________________ Serial Numbers: _______________________________________________________________ kVA Rating: __________________________________________________________________ Date Purchased: _______________________________________________________________ Date Installed: ________________________________________________________________ Location: _____________________________________________________________________ Input Voltage/Frequency: ______________________________________________________ Output Voltage/Frequency: _____________________________________________________ Battery Reserve Time: _________________________________________________________ Product Warranty Registration To register for warranty protection, visit the Service and Support section of our Web site at: www.liebert.com Click on Product Registration and fill out the form. TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.0 MECHANICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.0 CONTROL CONNECTIONS AND COMMUNICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.1 Control Cable and Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1.1 Programmable Relay Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2 Inter-Module Control wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.0 INSTALLATION DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.0 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 i FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 External Interface Board connections layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Breaker Interface Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Voltage and Current Sensing Terminal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Control wiring, Programmable Relay Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Programmable relay board dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Control wiring layout for Liebert NXL Power-Tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Liebert NXL Power-Tie System #1 layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Liebert NXL Power-Tie System #2 or #3 layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Liebert NXL Power-Tie control wiring for single system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 TABLES Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Programmable Relay Board pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cable group #22A - from SIB breaker interface board (BIB) to SIB breaker . . . . . . . . . . . . . . . . . 7 Cable group #22B - from SIB breaker interface board (BIB) to breaker motor operator (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Cable group #23A - from tie breaker interface board (BIB) to tie breaker . . . . . . . . . . . . . . . . . . . 7 Cable group #23B - from tie breaker interface board (BIB) to breaker motor operator (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Cable group #24A - from MBB breaker interface board (BIB) to MBB breaker . . . . . . . . . . . . . . . 7 Cable group #24B - from MBB breaker interface board (BIB) to breaker motor operator (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable group #25A - from MIB breaker interface board (BIB) to MIB breaker . . . . . . . . . . . . . . . . 8 Cable group #25B - from MIB breaker interface board (BIB) to breaker motor operator (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable group #26A - from LBB breaker interface board (BIB) to LBB breaker . . . . . . . . . . . . . . . . 8 Cable group #27A - parallel from SCC/UPS inter-module communication board to Liebert NXL Power-Tie inter-module communication board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable group #27B - redundant parallel from SCC/UPS inter-module communication board to Liebert NXL Power-Tie inter-module communication board. . . . . . . . . . . . . . . . . . . . . . . 9 Cable group #28A - parallel from Liebert NXL Power-Tie inter-module communication board to next Liebert NXL Power-Tie inter-module communication board . . . . . . . . . . . . . . . . . . 9 Cable group #28B - redundant parallel Liebert NXL Power-Tie inter-module communication board to next Liebert NXL Power-Tie inter-module communication board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cable group #29A - from MBB breaker interface board to SKRU interface . . . . . . . . . . . . . . . . . . 9 Cable group #29B - from MBB breaker interface board to SKRU interface . . . . . . . . . . . . . . . . . . 9 Cable group #32 - from Liebert NXL Power-Tie control terminal block to voltage and current sense points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Liebert NXL Power-Tie Control specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ii Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation of your Liebert NXL Power-Tie Controls. Read this manual thoroughly, paying special attention to the sections that apply to your installation, before working with the unit. Retain this manual for use by installing personnel. ! WARNING Risk of electrical shock. Can cause personal injury or death. Only properly trained and qualified personnel wearing appropriate safety headgear, gloves, shoes and glasses should be involved in installing the modules or preparing the modules for installation. When performing maintenance with any part of the equipment under power, service personnel and test equipment should be standing on rubber mats. In case of fire involving electrical equipment, use only carbon dioxide fire extinguishers or those approved for use in fighting electrical fires. Extreme caution is required when performing installation and maintenance. Special safety precautions are required for procedures involving handling, installation and maintenance of the UPS system. Observe all safety precautions in this manual before handling or installing the module. Observe all precautions in the Operation and Maintenance Manual before as well as during performance of all maintenance procedures. ! WARNING Risk of electrical shock and fire. Can cause equipment damage, personal injury or death. Under typical operation and with all doors closed, only normal safety precautions are necessary. The area around the system should be kept free of puddles of water, excess moisture and debris. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC voltmeter to ensure safety before making contact or using tools. Even when the power is turned Off, dangerously high potential electric charges may exist at the capacitor banks. All wiring must be installed by a properly trained and qualified electrician. All power and control wiring must comply with all applicable national, state and local codes. One person should never work alone, even if all power is disconnected from the equipment. A second person should be standing by to assist and to summon help in case of an accident. NOTE Materials sold hereunder cannot be used in the patient vicinity (e.g., use where UL, cUL or IEC 60601-1 is required). Medical applications, such as invasive procedures and electrical lifesupport equipment, are subject to additional terms and conditions. NOTICE This unit complies with the limits for a Class A digital device, pursuant to Part 15 Subpart J of the FCC rules. These limits provide reasonable protection against harmful interference in a commercial environment. This unit generates, uses and radiates radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this unit in a residential area may cause harmful interference that the user must correct at his own expense. Liebert® NXL™ Power-Tie Controls 1 Mechanical Installation 1.0 MECHANICAL INSTALLATION 1.1 Introduction The Liebert NXL Switchgear provides continuous, high-quality AC power to your business-critical equipment, such as telecommunication and data processing equipment. Liebert NXL UPSs will supply power that is free of the disturbances and variations in voltage and frequency common to utility power, which is subject to brownouts, blackouts, surges and sags. The Liebert NXL Power-Tie system provides manually initiated, uninterrupted transfers of a critical load bus between the two UPS systems. This topology permits one UPS and its associated distribution system to be shut down for maintenance while the load continues to be supplied by another UPS, without the necessity of transferring the load to bypass during shutdown or restart of the UPS being maintained. 1.2 Preliminary Checks This chapter is a guide to general procedures and practices that should be observed by the installing personnel. The particular conditions of each site will determine the applicability of such procedures. Before installing the Liebert NXL Power-Tie, please carry out the following preliminary checks: • Examine the Liebert NXL Power-Tie for transit damage, both internally and externally. Report any damage to the shipper immediately. • Verify that the correct equipment is being installed. The Liebert NXL Power-Tie cabinet has an identification tag on the interior doors listing the type, size and main calibration parameters of the UPS. • Verify that the UPS room satisfies the environmental conditions stipulated in the equipment specification, paying particular attention to the ambient temperature and air exchange system. 2 Liebert® NXL™ Power-Tie Controls Control Connections and Communication 2.0 CONTROL CONNECTIONS AND COMMUNICATION 2.1 Control Cable and Communication Figure 1 External Interface Board connections layout MAINT BYP ENABLE TB0821 ACT FILT TB035 CNTL P0831 P66C P99C P0832 AUX S PARE TEMP P0801 BATT GND FLT TB0815 EXTERNA L CAN MOB TB0811 MIB TB0830 ACT FILT STATUS TB0810 TB0816 RIB ON GEN P0808 TB0823 TB0829 EPO STATUS OPT PS TB1154B EXTERNA L CAN INT BATT CAN TB0819 MBB BYP CNTL TB0817 BIB RECT CNTL J5 TB0820 TB0818 REPO FORM C KEY STATUS INV CNTRLN REPO J4 BATT MTR TB1156 OP TB0826 TB0824 Figure 2 TB0813 TB0812 TB0825 LBS VO LTAGE TB1154A EXT BATT CAN Breaker Interface Board 2 3 4 T B1150 1 1 TB 1154 1 2 TB 1123 BREAKER INTERFACE BOARD BIB 3 4 2 3 TB 1158 TB 1151 1 2 3 6 7 48VDC Shunt Trip 5 1 4 5 Form-C Aux Contacts 2 6 7 8 1 P 1155 Liebert® NXL™ Power-Tie Controls 2 Optional Motor Operator 4 5 CAUTION: HAZARDOUS VOLTAGES 3 Control Connections and Communication Figure 3 Voltage and Current Sensing Terminal TB1 TB2 TB3 Note 1 TB4 CT SHORTING TABLE TB5 TB6 TB7 Critical Load Bus, Phase A CT X1 TB8 Critical Load Bus, Phase A CT X2 TB9 Critical Load Bus, Phase B CT X1 TB10 Critical Load Bus, Phase B CT X2 TB11 Critical Load Bus, Phase C CT X1 TB12 Critical Load Bus, Phase C CT X2 TB13 UPS Source, Phase A CT X1 TB14 UPS Source, Phase A CT X2 TB15 UPS Source, Phase B CT X1 TB16 UPS Source, Phase B CT X2 TB17 UPS Source, Phase C CT X1 TB18 UPS Source, Phase C CT X2 TB19 TIE Bus Voltage, Phase A TB20 TIE Bus Voltage, Phase B TB21 TIE Bus Voltage, Phase C TB22 Neutral TB23 Critical Load Bus Voltage, Phase A TB24 Critical Load Bus Voltage, Phase B TB25 Critical Load Bus Voltage, Phase C TB26 Neutral TB27 Bypass Source Voltage, Phase A TB28 Bypass Source Voltage, Phase B TB29 Bypass Source Voltage, Phase C TB30 Neutral TB31 1 Future TB32 1 Future TB33 1 Future TB34 1 TB35 Future UPS Source Voltage, Phase A TB36 UPS Source Voltage, Phase B TB37 UPS Source Voltage, Phase C TB38 Neutral F1 8A F2 8A F3 8A F4 8A F5 8A F6 UPS Source Power Supply , Phase A TB# SHORTS CT TB1 TB2 TB3 TB4 TB5 TB6 LOAD I PHA LOAD I PHB LOAD I PHC UPS I PHA UPS I PHB UPS I PHC CAUTION: TB19–TB38 and F1-F6 connected to HAZARDOUS VOLTAGES NOTES: 1. TB1–TB6 are shorting switches . During normal operation , these devices are open . When button is depressed and turned 90˚ (locked position) the associated CT is shorted. Reference Table “CT SHORTING TABLE” on this sheet. 2. TB19-TB38 are disconnect devices . During normal operation these devices are closed. All external wiring into TB 19-TB38 must be fused at the source. UPS Source Power Supply , Phase B Bypass Source Power Supply , Phase A Bypass Source Power Supply , Phase B Optional Power Supply Optional Power Supply 8A 4 Liebert® NXL™ Power-Tie Controls Control Connections and Communication 2.1.1 Programmable Relay Board The Programmable Relay Board (PRB) provides a means to trigger an external device when an event occurs in the Liebert NXL. Each PRB has eight channels. Each channel has Form-C dry contacts rated at 1A @ 30VDC or 125VAC @ 0.45A. Any alarm/event can be programmed to any channel or channels. Up to four (4) events can be programmed to a relay. If multiple events are grouped to one relay, group the events logically to simplify troubleshooting when an event is triggered. The same alarm/event can be programmed to more than one channel. Up to two Programmable Relay Boards can be installed in the Liebert NXL for a total of 16 channels. Programming is performed through the HMI touchscreen display. NOTE Up to two (2) PRB’s can be installed in the Liebert NXL. Figure 4 Control wiring, Programmable Relay Board 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 J71 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 J72 1 2 3 1 2 3 4 5 6 7 8 9 10111213141516 J73 J74 1. 2. 3. 4. 5. 6. Customer control wiring connection points are terminals 1 through 15. (Pin 16 not used on J71, J72, and J73.) Programmable Relay Board option includes eight signal channels with two Form-C dry contacts per channel (see Table 1). All control wiring (by others) must be run separate from power wiring. Control wiring runs should not be combined in the same conduit. Contact ratings: 1A @ 30VDC or 125VAC @ 0.45A Maximum cable length 500 ft. (152m) with #16AWG and flexible stranded cable. All wiring must be in accordance with national and local electrical codes. Table 1 Terminal Block Programmable Relay Board pinout Channel CH1 J71 CH2 CH3 J72 CH4 CH5 CH6 TB3 J74 CH7 CH8 A B A B A B A B A B A B A B A B Pin No. Common Normally Closed Normally Open 1-3 4-6 7-9 10-12 13-15 1-3 4-6 7-9 10-12 13-15 1-3 4-6 7-9 10-12 13-15 1-3 1 4 7 10 13 1 4 7 10 13 1 4 7 10 13 1 2 5 8 11 14 2 5 8 11 14 2 5 8 11 14 2 3 6 9 12 15 3 6 9 12 15 3 6 9 12 15 3 Note: Pin 16 not used on J71, J72, and J73. Liebert® NXL™ Power-Tie Controls 5 Control Connections and Communication Configuring the Programmable Relay Board Settings 1. Press Internal Option Settings from the Config menu. 2. Press which Programmable Relay Board will be configured. The Programmable Relay Board dialog box is displayed. 3. Press the Relay channel 4. Press up to four (4) events. Selected events will show up under Relay 1 Assignment. NOTE To deselect an event, click on the event. 5. Repeat Steps 3 and 4 for each relay. 6. Press SAVE to keep the settings. Figure 5 Programmable relay board dialog box • Assignment—0 to 4 event (default: 0) • Delay, sec—0 to 99.9 (default: 0) 6 Liebert® NXL™ Power-Tie Controls Control Connections and Communication 2.2 Inter-Module Control wiring NOTE Unless otherwise noted, use copper or aluminum conductors suitable for at least 75°C. Table 2 Cable group #22A - from SIB breaker interface board (BIB) to SIB breaker Terminal Designation From To TB1150-3 TB1150-4 Remote Breaker Contacts TB1150-5 Table 3 SIB AUX CONTACT, CLOSED = CB IS OPEN SIB AUX CONTACT, CLOSED = CB IS CLOSED SIB 48VDC TRIP COIL (-) Cable group #22B - from SIB breaker interface board (BIB) to breaker motor operator (optional) From To TB1151-1 Remote Breaker Motor Operator Contacts TB1151-5 Signal Name AC LINE MOTOR OPERATOR CLOSE From Signal Name To TB1150-1 TB1150-2 TB1150-3 TB1150-4 #14-22AWG 500FT (150m) Maximum Length TIE AUX CONTACT COMMON Remote Breaker Contacts TB1150-5 TIE AUX CONTACT, CLOSED = CB IS OPEN TIE AUX CONTACT, CLOSED = CB IS CLOSED TIE 48VDC TRIP COIL (-) #14-22AWG 500FT (150m) TIE 48VDC TRIP COIL (+) Cable group #23B - from tie breaker interface board (BIB) to breaker motor operator (optional) Terminal Designation From To TB1151-1 Remote Breaker Motor Operator Contacts TB1151-5 Table 6 Maximum Length Cable group #23A - from tie breaker interface board (BIB) to tie breaker Terminal Designation Table 5 #14-22AWG 500FT (150m) SIB 48VDC TRIP COIL (+) Terminal Designation Table 4 Maximum Length SIB AUX CONTACT COMMON TB1150-1 TB1150-2 Signal Name Signal Name AC LINE MOTOR OPERATOR CLOSE Maximum Length #14-22AWG 500FT (150m) Cable group #24A - from MBB breaker interface board (BIB) to MBB breaker Terminal Designation From Signal Name To TB1150-1 MBB AUX CONTACT COMMON TB1150-2 MBB AUX CONTACT, CLOSED = CB IS OPEN TB1150-3 TB1150-4 Remote Breaker Contacts TB1150-5 Liebert® NXL™ Power-Tie Controls MBB AUX CONTACT, CLOSED = CB IS CLOSED MBB 48VDC TRIP COIL (-) MBB 48VDC TRIP COIL (+) 7 Maximum Length #14-22AWG 500FT (150m) Control Connections and Communication Table 7 Cable group #24B - from MBB breaker interface board (BIB) to breaker motor operator (optional) Terminal Designation From To TB1151-1 Remote Breaker Motor Operator Contacts TB1151-5 Table 8 AC LINE Cable group #25A - from MIB breaker interface board (BIB) to MIB breaker TB1150-3 TB1150-4 MIB AUX CONTACT COMMON Remote Breaker Contacts TB1150-5 Table 9 MIB AUX CONTACT, CLOSED = CB IS OPEN MIB AUX CONTACT, CLOSED = CB IS CLOSED MIB 48VDC TRIP COIL (-) Cable group #25B - from MIB breaker interface board (BIB) to breaker motor operator (optional) From To TB1151-1 Remote Breaker Motor Operator Contacts Table 10 TB1150-1 TB1150-2 TB1150-3 Table 11 Maximum Length Signal Name AC LINE #14-22AWG 500FT (150m) MOTOR OPERATOR CLOSE Cable group #26A - from LBB breaker interface board (BIB) to LBB breaker Terminal Designation From #14-22AWG 500FT (150m) MIB 48VDC TRIP COIL (+) Terminal Designation TB1151-5 Maximum Length Signal Name To TB1150-1 TB1150-2 #14-22AWG 500FT (150m) MOTOR OPERATOR CLOSE Terminal Designation From Maximum Length Signal Name Remote Breaker Contacts Maximum Length Signal Name To LBB AUX CONTACT COMMON LBB AUX CONTACT, CLOSED = CB IS OPEN LBB AUX CONTACT, CLOSED = CB IS CLOSED #14-22AWG 500FT (150m) Cable group #27A - parallel from SCC/UPS inter-module communication board to Liebert NXL Power-Tie inter-module communication board Terminal Designation Signal Name From To P3101-3 P3101-3 SYSTEM CAN +24V P3101-4 P3101-4 SYSTEM CAN COMMON P3101-7 P3101-7 GROUND P3101-14 P3101-14 GROUND P3101-12 P3101-12 LBS SYNCH CAN +24V P3101-13 P3101-13 LBS SYNCH CAN COMMON Maximum Length #18AWG 1000FT (300m) Note: Must use Belden 8106 or (3) Belden 8102; outer shield drain wire must be connected to pins 7 and 14 at each connector. 8 Liebert® NXL™ Power-Tie Controls Control Connections and Communication Table 12 Cable group #27B - redundant parallel from SCC/UPS inter-module communication board to Liebert NXL Power-Tie inter-module communication board Terminal Designation Maximum Length Signal Name From To P3103-3 P3103-3 REDUNDANT SYSTEM CAN +24V P3103-4 P3103-4 REDUNDANT SYSTEM CAN COMMON P3103-7 P3103-7 GROUND P3103-14 P3103-14 GROUND P3103-12 P3103-12 REDUNDANT LBS SYNCH CAN +24V P3103-13 P3103-13 REDUNDANT LBS SYNCH CAN COMMON #18AWG 1000FT (300m) Note: Must use Belden 8106 or (3) Belden 8102; outer shield drain wire must be connected to pins 7 and 14 at each connector. Table 13 Cable group #28A - parallel from Liebert NXL Power-Tie inter-module communication board to next Liebert NXL Power-Tie inter-module communication board Terminal Designation Maximum Length Signal Name From To P3101-1 P3101-1 SHARE CAN +24V P3101-2 P3101-2 SHARE CAN COMMON P3101-7 P3101-7 GROUND P3101-14 P3101-14 GROUND #18AWG 1000FT (300m) P3101-8 P3101-8 PWM SYNCH CAN +24V P3101-9 P3101-9 PWM SYNCH CAN COMMON Note: Must use Belden 8106 or (3) Belden 8102; outer shield drain wire must be connected to pins 7 and 14 at each connector. Table 14 Cable group #28B - redundant parallel Liebert NXL Power-Tie inter-module communication board to next Liebert NXL Power-Tie inter-module communication board Terminal Designation From To P3103-3 P3103-3 Maximum Length Signal Name SHARE CAN +24V P3103-4 P3103-4 SHARE CAN COMMON P3103-7 P3103-7 GROUND P3103-14 P3103-14 GROUND P3103-12 P3103-12 PWM SYNCH CAN +24V P3103-13 P3103-13 PWM SYNCH CAN COMMON #18AWG 1000FT (300m) Note: Must use Belden 8106 or (3) Belden 8102; outer shield drain wire must be connected to pins 7 and 14 at each connector. Table 15 Cable group #29A - from MBB breaker interface board to SKRU interface Terminal Designation From TB1158-6 TB1158-4 TB1158-5 Table 16 SKRU CONTACTS Maximum Length Signal Name To KEY STATUS SWITCH, CLOSED = KEY RELEASED KEY STATUS SWITCH, COMMON KEY STATUS SWITCH, CLOSED = KEY CAPTIVE #14-22AWG 500FT (150m) Cable group #29B - from MBB breaker interface board to SKRU interface Terminal Designation From To TB1151-1 SKRU CONTACTS TB1151-5 Liebert® NXL™ Power-Tie Controls Signal Name CLOSED = ENABLE SKRU MAINTENANCE BYPASS CABINET, COMMON 9 Maximum Length #14-22AWG 164FT (50m) Control Connections and Communication Table 17 Cable group #32 - from Liebert NXL Power-Tie control terminal block to voltage and current sense points Terminal Designation From Maximum Length Signal Name To TB7 Critical Load Bus, Phase A CT X1 TB8 Critical Load Bus, Phase A CT X2 TB9 Critical Load Bus, Phase B CT X1 TB10 Critical Load Bus, Phase B CT X2 TB11 Critical Load Bus, Phase C CT X1 TB12 Critical Load Bus, Phase C CT X2 TB13 UPS SOURCE, Phase A CT X1 TB14 UPS SOURCE, Phase A CT X2 TB15 UPS SOURCE, Phase B CT X1 TB16 UPS SOURCE, Phase B CT X2 TB17 UPS SOURCE, Phase C CT X1 TB18 UPS SOURCE, Phase C CT X2 TB19 TIE BUS VOLTAGE, PHASE A TB20 TIE BUS VOLTAGE, PHASE B TB21 TIE BUS VOLTAGE, PHASE C TB22 NEUTRAL TB23 CRITICAL LOAD BUS VOLTAGE, PHASE A TB24 TB25 TB26 TB27 VOLTAGE & CURRENT SENSE POINTS CRITICAL LOAD BUS VOLTAGE, PHASE B CRITICAL LOAD BUS VOLTAGE, PHASE C NEUTRAL 22-12AWG/ 500FT (150m) BYPASS SOURCE VOLTAGE, PHASE A TB28 BYPASS SOURCE VOLTAGE, PHASE B TB29 BYPASS SOURCE VOLTAGE, PHASE C TB30 NEUTRAL TB31 FUTURE TB32 FUTURE TB33 FUTURE TB34 FUTURE TB35 UPS SOURCE VOLTAGE, PHASE A TB36 UPS SOURCE VOLTAGE, PHASE B TB37 UPS SOURCE VOLTAGE, PHASE C TB38 NEUTRAL F1 UPS Source Power Supply, Phase A F2 UPS Source Power Supply, Phase B F3 Bypass Source Power Supply, Phase A F4 Bypass Source Power Supply, Phase B F5 Optional Power Supply F6 Optional Power Supply 10 Liebert® NXL™ Power-Tie Controls Installation Drawings 3.0 INSTALLATION DRAWINGS Figure 6 Control wiring layout for Liebert NXL Power-Tie REPO CG # 22 CG #1 CG # 23 CG # 24 CG # 22 Power Tie 3 Controls CG # 23 CG # 24 System #1 Power Tie 1 Controls CG # 25 CG # 26 CG # 27 CG # 29 CG # 26 CG # 32 CG # 27 CG # 29 CG #28 CG #28 CG # 32 CG # 22 CG # 23 CG # 24 System #2 CG # 25 CG # 25 Power Tie 2 Controls CG # 26 CG # 27 CG # 29 CG # 32 Liebert® NXL™ Power-Tie Controls 11 System #3 Installation Drawings Figure 7 Liebert NXL Power-Tie System #1 layout Liebert Intellislot Ports Voltage and Current Sensor Terminal Blocks Breaker Interface Board (SIB) Breaker Interface Board (Tie) External Interface Board (EIB Breaker Interface Board (MBB, Optional) Breaker Interface Board (MIB, Optional) Breaker Interface Board (LBB, Optional) Option Box FRONT VIEW To Associated SM/MM System High Voltage (External) To Associated SM/MM System High Voltage (External) Low Voltage (External) Low Voltage (External) High Voltage (External) To Associated SM/MM System TOP VIEW BOTTOM VIEW 12 539652 Page 1, Rev. 3 Liebert® NXL™ Power-Tie Controls Installation Drawings Figure 8 Liebert NXL Power-Tie System #2 or #3 layout Voltage and Current Sensor Terminal Blocks Breaker Interface Board (SIB) Breaker Interface Board (Tie) Breaker Interface Board (MBB, Optional) Breaker Interface Board (MIB, Optional) Breaker Interface Board (LBB, Optional) Option Box FRONT VIEW To Associated SM/MM System High Voltage (External) To Associated SM/MM System Low Voltage (External) High Voltage (External) Low Voltage (External) High Voltage (External) To Associated SM/MM System BOTTOM VIEW TOP VIEW Liebert® NXL™ Power-Tie Controls 539652 Pg. 02, Rev. 03 13 To MIB Breaker Interface Board T o SIB Breaker I nterface Board 14 NEUTRAL BYPASS SOURCE, ΦC BYPASS SOURCE, ΦB BYPASS SOURCE, ΦA To MBB Breaker Interface Board STATUS CLOSED 1 STATUS OPEN 1 ST ATUS COM 1 SHUNT TRIP SHUNT TRIP CLO SE 120VAC STATUS CLOSED 1 STATUS OPEN 1 ST ATUS COM 1 SHUNT TRIP SHUNT TRIP CLO SE 120VAC STATUS CLOSED 1 STATUS OPEN 1 ST ATUS COM 1 SHUNT TRIP SHUNT TRIP CLO SE 120VAC UPS Source, Phase C CT X2 UPS Source, Phase C CT X1 UPS Sourc e, Phase B CT X2 UPS Sourc e, Phase B CT X1 UPS Sourc e, Phase A CT X2 UPS Sourc e, Phase A CT X1 SIB ST MIB 48VDC ST CLOSE COIL MBB MAINTENANCE BYPASS BREAKER 48VDC CLOSE COIL MAINTENANCE ISOLATION BREAKER 48VDC ST CLOSE COIL SYSTEM ISOLATION BREAKER NEUTRAL Bypass Source Power Supply, Phase B Bypass Source Power Supply, Phase A Bypass Source Voltage, Phase C Bypass Source Voltage, Phase B Bypass Source Voltage, Phase A To Tie Breaker Interface Board UPS Source Power Supply, Phase B UPS Source Power Supply, Phase A UPS Source Voltage, Phase C UPS Source Voltage, Phase B UPS Sourc e Voltage, Phase A 48VDC ST CLOSE COIL Critical Load Bus Voltage, Phase C Critical Load Bus Voltage, Phase B Critical Load Bus Voltage, Phase A Critical Load Bus, Phas e C CT X2 Critical Load Bus, Phas e C CT X1 Critical Load Bus, Phas e B CT X2 Critical Load Bus, Phas e B CT X1 Critical Load Bus, Phas e A CT X2 ST TIE LBB TIE BREAKER 48VDC CLOSE COIL LOAD BANK BREAKER Critical Load Bus, Phas e A CT X1 STATU S CLOSED 1 STATUS OPEN 1 STATUS COM 1 SHUNT T RIP SHUNT T RIP CLOSE 120VAC STATU S CLOSED 1 STATUS OPEN 1 STATUS COM 1 SHUNT T RIP SHUNT T RIP CLOSE 120VAC TIE Bus Voltage, Phase A TIE Bus Voltage, Phase C TIE Bus Voltage, Phase B NEUTRAL CRITICAL LOAD BUS, ΦC CRITICAL LOAD BUS, ΦB CRITICAL LOAD BUS, ΦA NEUTRAL TIE BUS, ΦC TIE BUS, ΦB TIE BUS, ΦA NEUTRAL LOAD BANK, ΦC LOAD BANK, ΦB LOAD BANK, ΦA Figure 9 1. Star Power Tie configuration shown. 2. Motor operator and shunt trip connections shown for all circuit breakers, although MIB, MBB and LBB may be manually operated types in some systems. NEUTRAL UPS SOURCE, ΦC UPS SOURCE, ΦB UPS SOURCE, ΦA Installation Drawings Liebert NXL Power-Tie control wiring for single system Liebert® NXL™ Power-Tie Controls Specifications 4.0 SPECIFICATIONS Table 18 Liebert NXL Power-Tie Control specifications Environmental Parameters Storage Temperature Range, °F (°C) -13 to 158 (-25 to 70) Operating Temperature Range, °F (°C) Relative Humidity Maximum Altitude Above mean sea level, ft (m) Liebert® NXL™ Power-Tie Controls 32 to 104 (0 to 40) (UPS) 95% or less Non-Condensing (Operating and Non-Operating) 4920 (1500) (as per IEC 62040/3) - 1% Max kW derate / 328 rise between 4921-9842 (100m rise between 1500-3000m) 15 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™ from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, embedded computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and connectivity. All solutions are supported globally by local Emerson Network Power service technicians. Liebert AC power, precision cooling and monitoring products and services from Emerson Network Power deliver Efficiency Without Compromise™ by helping customers optimize their data center infrastructure to reduce costs and deliver high availability. Technical Support / Service Web Site www.liebert.com Monitoring liebert.monitoring@emerson.com 800-222-5877 Outside North America: +00800 1155 4499 Single-Phase UPS & Server Cabinets liebert.upstech@emerson.com 800-222-5877 Outside North America: +00800 1155 4499 Three-Phase UPS & Power Systems 800-543-2378 Outside North America: 614-841-6598 Environmental Systems 800-543-2778 Outside the United States: 614-888-0246 Locations United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111 Fax: +39 049 5841 257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 Fax: +63 2 730 9572 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2011 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-25520_REV4_06-13 Emerson Network Power. The global leader in enabling Business-Critical Continuity™ AC Power Connectivity Embedded Computing Embedded Power DC Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2011 Emerson Electric Co.