Quick Menu
To navigate this presentation use slide 4 and click on the numbered icons on the left
Aim
To introduce personnel to the Dräger PSS
7000t BA Set.
By the end of this session personnel
Will have sufficient knowledge and understanding of the functions relating to the use of the Dräger PSS 7000t BA
Quick Selection Menu
1. Cylinder
2. Reducer
3. Back plate
4. Harness
3 Slides
1 Slide
3 Slides
3 Slides
5. Pneumatics
6. LDV
2 Slides
1 Slide
7. FPS 7000 Face Mask
1 Slide
8. Bodyguard 7000t EMU
3 Slides
9. Log Off
HIGH PERFORMANCE LIGHT WEIGHT COMPRESSED AIR CYLINDER
Final Resin Layer
Glass Wrap
Carbon Wrap
Aluminium Liner
Anti corrosive layer
Copper anti debris tube
Right angled cylinder valve
NEXT
Working Pressure (bar)
Water Volume (L) Cylinder serial number
Date of manufacture + 5 # years…
PREVIOUS NEXT
Drager
•
• 9 ltr Vol x 300 Bar = 2700 ltr
2700 x 0.9 ( correction factor )
= 2430
= 2430
50 ltrs Min
• Total Duration = 49 Mins
• Safety Margin - 12 Mins
• Working Duration = 37 Mins
PREVIOUS
MENU
Anti-tamper disk
Longer Thread for 300 bar
Built in Anti-vibration O-ring
Spring loaded reducer mounting
Pneumatic Whistle
2 nd wearer ‘Y-Piece’
O-ring for pressure seal
Bronze sintered filter
MENU
High strength light-weight carbon composite
Pivoting/swivelling waist belt
Fully adjustable yoke to 3 sizes
(S,M,L)
Built-in carrying handles
Integrated electronics
Integrated hoses
Modular design
NEXT
Spring Clips size adjustment
Bodyguard
( Gauge )
Size Markings (S,M,L)
Hose routed through back plate
Battery release point
Spring-loaded waist belt pivot point
Battery
( A fully charged battery will last for 8 hrs )
Bodyguard pressure module & Battery pack
PREVIOUS NEXT
Carrying Handles
Auxiliary take off
Reducer Housing
LDV
Rubber Buffer Charging point
PREVIOUS
MENU
Neoprene rubber bonded to polyester fibre matrix
High wear resistance
Harness remains in position
High temperature performance
Material grips the wearers clothing and prevents slippage.
NEXT
Shoulder straps
(designed to grip wearers PPE)
Spark-proof buckles
Trident clip
PREVIOUS NEXT
Hose retaining flaps
Cylinder strap with
“camlock” buckle
Quick release
Waist belt assembly
Quick release shoulder harness and waist belt
Quick assembly and disassembly
Quick turnaround times in the workshop
Easy cleaning
Heavy duty stainless steel friction buckles
Webbing will not twist within buckle
Easy adjustment with gloves
PREVIOUS
MENU
Filter and ‘O’ ring replaced annually.
Reducer exchanged every ten years.
Reducer output 6-9 bar (dynamic & static pressures )
Reducer relief valve lift off pressure 11-16 bar.
Choke screw set to 25 lts per minute.
Pneumatic LPWW operates at 60 Bar + or – 5 Bar
Whistle uses approx. 4 ltrs of air per minute.
Positive pressure in mask between 0.1 and 0.3 bar above atmosphere…
NEXT
300 Bar – Nominal Charge (100%)
270 Bar – Minimum for full test (New Cylinder) (90%)
245 Bar - Minimum on completion of General test
240 Bar – Minimum Initial Entry
150 Bar – Minimum Re-entry
(80%)
(50%)
120 Bar – Minimum for Decontamination
74 Bar – Bodyguard LPWW
60 +/- 5 Bar – Pneumatic (failsafe LPWW)
(40%)
(25%)
(20%)
PREVIOUS
MENU
LDV Release Buttons
Re-set button
Swivel coupling
Constant flow switch
MENU
Polycarbonate Visor
Voice Enhancement power button on R/H side
LDV Port
Exhalation Valve
5 Point head harness attachments
Mask body
Inner Mask
(orinasal)
Mushroom Valve
Voice Enhancement
Speaker
PTT Button
Integrated comm ’s speaker
Radio connection
MENU
7000
Digital pressure reading
Radial segments pressure and timing Right hand button
Left Hand button
Distress alarm button
Time to whistle
Blue, Red & Green LED ’s ADSU Tally key
Hose/Cable assembly to electronic pressure transmitter module
NEXT
7000
Provides continuous monitoring of the SCBA.
( GREEN LED flashes every second when bodyguard is in operation,
When linked to Merlin Board two additional BLUE LEDs flash intermittently )
Monitoring of the cylinder pressure.
( Digital reading updated every 20 seconds )
Time to whistle (TTW). Digital reading.
( Digital reading updated every 20 seconds )
Button activated Distress Signal Unit.
( DSU 96-105 db )...
PREVIOUS NEXT
7000
Movement sensor and Automatic Distress Signal Unit.
(If no movement detected after 30 seconds a pre-alarm will sound, if no movement after a further 15 seconds full alarm sounds with 2 RED & 2 BLUE
LEDs flashing intermittently)
Back light feature.
(On pressing either Left or Right button the body guard unit will illuminate the display for 3-5 seconds)
Electronic Whistle Warning Unit.
(Electronic whistle will operate at 74 Bar , 90 db)
PREVIOUS
MENU
A
(Close Cylinder wheel and vent Air
Supply)
B
bodyguard will
(allow gauge to read ZERO, automatically turn off within 20 sec )
C
a
(Switch off comms ; radio & speech enhancer)
This will ensure that the set has logged off from the Merlin board
MENU
MENU