Aim

To introduce personnel to the Dräger PSS

7000t BA Set.

Objectives:

By the end of this session personnel

Will have sufficient knowledge and understanding of the functions relating to the use of the Dräger PSS 7000t BA

Dräger PSS 7000

Quick Selection Menu

1. Cylinder

2. Reducer

3. Back plate

4. Harness

3 Slides

1 Slide

3 Slides

3 Slides

5. Pneumatics

6. LDV

2 Slides

1 Slide

7. FPS 7000 Face Mask

1 Slide

8. Bodyguard 7000t EMU

3 Slides

9. Log Off

Cylinder:

HIGH PERFORMANCE LIGHT WEIGHT COMPRESSED AIR CYLINDER

Final Resin Layer

Glass Wrap

Carbon Wrap

Aluminium Liner

Anti corrosive layer

Copper anti debris tube

Right angled cylinder valve

NEXT

Cylinder:

Working Pressure (bar)

Water Volume (L) Cylinder serial number

Date of manufacture + 5 # years…

PREVIOUS NEXT

Bar Cylinder Calculations

Drager

• 9 ltr Vol x 300 Bar = 2700 ltr

2700 x 0.9 ( correction factor )

= 2430

= 2430

50 ltrs Min

• Total Duration = 49 Mins

• Safety Margin - 12 Mins

• Working Duration = 37 Mins

PREVIOUS

MENU

Reducer

Anti-tamper disk

Longer Thread for 300 bar

Built in Anti-vibration O-ring

Spring loaded reducer mounting

Pneumatic Whistle

2 nd wearer ‘Y-Piece’

O-ring for pressure seal

Bronze sintered filter

MENU

Back Plate

 High strength light-weight carbon composite

 Pivoting/swivelling waist belt

 Fully adjustable yoke to 3 sizes

(S,M,L)

 Built-in carrying handles

 Integrated electronics

 Integrated hoses

 Modular design

NEXT

Back Plate

Spring Clips size adjustment

Bodyguard

( Gauge )

Size Markings (S,M,L)

Hose routed through back plate

Battery release point

Spring-loaded waist belt pivot point

Battery

( A fully charged battery will last for 8 hrs )

Bodyguard pressure module & Battery pack

PREVIOUS NEXT

Back Plate

Carrying Handles

Auxiliary take off

Reducer Housing

LDV

Rubber Buffer Charging point

PREVIOUS

MENU

Harness:

 Neoprene rubber bonded to polyester fibre matrix

 High wear resistance

 Harness remains in position

 High temperature performance

 Material grips the wearers clothing and prevents slippage.

NEXT

Harness

Shoulder straps

(designed to grip wearers PPE)

Spark-proof buckles

Trident clip

PREVIOUS NEXT

Hose retaining flaps

Cylinder strap with

“camlock” buckle

Quick release

Waist belt assembly

Harness

 Quick release shoulder harness and waist belt

 Quick assembly and disassembly

 Quick turnaround times in the workshop

 Easy cleaning

 Heavy duty stainless steel friction buckles

 Webbing will not twist within buckle

 Easy adjustment with gloves

PREVIOUS

MENU

Pneumatics

 Filter and ‘O’ ring replaced annually.

 Reducer exchanged every ten years.

 Reducer output 6-9 bar (dynamic & static pressures )

 Reducer relief valve lift off pressure 11-16 bar.

 Choke screw set to 25 lts per minute.

 Pneumatic LPWW operates at 60 Bar + or – 5 Bar

 Whistle uses approx. 4 ltrs of air per minute.

 Positive pressure in mask between 0.1 and 0.3 bar above atmosphere…

NEXT

Pressures

 300 Bar – Nominal Charge (100%)

 270 Bar – Minimum for full test (New Cylinder) (90%)

 245 Bar - Minimum on completion of General test

 240 Bar – Minimum Initial Entry

 150 Bar – Minimum Re-entry

(80%)

(50%)

 120 Bar – Minimum for Decontamination

 74 Bar – Bodyguard LPWW

 60 +/- 5 Bar – Pneumatic (failsafe LPWW)

(40%)

(25%)

(20%)

PREVIOUS

MENU

Lung Demand Valve

(LDV)

LDV Release Buttons

Re-set button

Swivel coupling

Constant flow switch

MENU

FPS 7000 Face Mask

Polycarbonate Visor

Voice Enhancement power button on R/H side

LDV Port

Exhalation Valve

5 Point head harness attachments

Mask body

Inner Mask

(orinasal)

Mushroom Valve

Voice Enhancement

Speaker

PTT Button

Integrated comm ’s speaker

Radio connection

MENU

Bodyguard

7000

Digital pressure reading

Radial segments pressure and timing Right hand button

Left Hand button

Distress alarm button

Time to whistle

Blue, Red & Green LED ’s ADSU Tally key

Hose/Cable assembly to electronic pressure transmitter module

NEXT

Bodyguard

7000

 Provides continuous monitoring of the SCBA.

( GREEN LED flashes every second when bodyguard is in operation,

When linked to Merlin Board two additional BLUE LEDs flash intermittently )

 Monitoring of the cylinder pressure.

( Digital reading updated every 20 seconds )

 Time to whistle (TTW). Digital reading.

( Digital reading updated every 20 seconds )

 Button activated Distress Signal Unit.

( DSU 96-105 db )...

PREVIOUS NEXT

Bodyguard

7000

 Movement sensor and Automatic Distress Signal Unit.

(If no movement detected after 30 seconds a pre-alarm will sound, if no movement after a further 15 seconds full alarm sounds with 2 RED & 2 BLUE

LEDs flashing intermittently)

 Back light feature.

(On pressing either Left or Right button the body guard unit will illuminate the display for 3-5 seconds)

 Electronic Whistle Warning Unit.

(Electronic whistle will operate at 74 Bar , 90 db)

PREVIOUS

MENU

Log Off

 A

– AIR SUPPLY

(Close Cylinder wheel and vent Air

Supply)

 B

– BODYGUARD

bodyguard will

(allow gauge to read ZERO, automatically turn off within 20 sec )

 C

– COMMS

a

(Switch off comms ; radio & speech enhancer)

This will ensure that the set has logged off from the Merlin board