Agenda Facts about Nexans Technics Cat 6 versus Cat 5 Standardization – What is Deembedding? Nexans Solutions Class D/E/F, Essential Installation Issues/Installation practice FO theory/FO practice Tendencies in Structured Cabling / FTTW Nexans Cabling Solutions, Jan 2004 2 CLASS D 2002 What about our ... 5 … solution ? Nexans Cabling Solutions, Jan 2004 3 CLASS D 2002 5 cable : UTP Previous: CAT 5E 350 / Symtek Tested and specified to 350 MHZ Guaranteed performance : 155 MHz LSZH (orange) or PVC (dark grey) jacket Nexans Cabling Solutions, Jan 2004 4 CLASS D 2002 5 cable : F²TP Tested and specified to 350 MHZ Guaranteed performance : 155 MHz LSZH (orange) or PVC (dark grey) jacket Screen efficiency : 10 x better easy to install Nexans Cabling Solutions, Jan 2004 5 CLASS D 2002 -5 SNAP-IN RANGE Fully modular outlets and patch panels Compatible with ‘keystone’ dimensions Toolless, comfort tool Full Range Unscreened Screened Shielded Nexans Cabling Solutions, Jan 2004 6 Snap in: modular hardware and Empty Modular patch panel • For 24 Snap-in connectors • With or withour clip-on • Automatic grounding Nexans Cabling Solutions, Jan 2004 7 Snap in: modular hardware and Empty Modular outlet • For 2 Snap-in connectors Nexans Cabling Solutions, Jan 2004 8 Snap in: modular hardware and Empty Modular Zone Distribution box • For 12 Snap-in connectors Nexans Cabling Solutions, Jan 2004 9 CLASS D 2002 MEGA 45 TWISTED PAIR LABELLING SYSTEM SHUTTER FRONTSIDE CONNECTION 45x45 1 or 2 RJ45 Screened/Unscreened NEXT better than 40 dB between every pair combination Contacts at frontside for convenient installation Contacts colour coding in conformity with cable colour coding Plastic material is UL 94V0. Nexans Cabling Solutions, Jan 2004 10 CLASS D 2002 OMEGA 1 HU patch panel High density (24 RJ45) Standard EMC pack Easy to install (Front side connection) 1Hu 24rj45 Integrated Clip-on cable guide Easy to manage Twisted pair modules screened unscreened Nexans Cabling Solutions, Jan 2004 11 Class E Solution 6 Nexans Cabling Solutions, Jan 2004 12 Class E Solution Class E / Cat 6 bandwidth up to 200MHz RJ45 connectivity backwards compatibility UTP and FTP technology the Powersum ACR is positive @ 200MHz, the ACR is 3dB @ 200MHz for the channel, or an ACR of 7.7dB for the permanent link useful to characterise balanced cabling beyond 0dB ACR (up to 250 MHz) Nexans Cabling Solutions, Jan 2004 13 Class E Solution Nexans Class E response 6 cable C3 cross member (high grade polyethylene) Nexans Cabling Solutions, Jan 2004 14 Class E Solution Guaranteed performance : 250 MHz Far exceeding today’s requirements: future proof Cable types for specific environments : F²TP and UTP LSZH and PVC version available … the best cat.6 cable you can find ! Nexans Cabling Solutions, Jan 2004 15 LANmark 6: cable The C³ (Central Crosstalk Cancellation) separates the pairs and locks them into place Nexans Cabling Solutions, Jan 2004 16 LANmark 6: cable the cross guarantees a certain distance between the pairs in case of pressure Nexans Cabling Solutions, Jan 2004 17 LANmark F²TP cable HIGHER EMC PERFORMANCES ! EMC performances comparable to SFTP. ! GAIN ON INSTALLATION No risk to cut the foil off when stripping Only one foil to connect More flexible foils easier to manipulate Quick and reliable installation 40 µm Dual Foil FTP 2x 25 µm Nexans Cabling Solutions, Jan 2004 18 Class E Solution LANmark: cable design Unique C3 (central crosstalk cancellation) construction: central plastic element locks pairs into place In FTP and UTP version Reduced NEXT and FEXT through crosstalk cancellation design Extremely stable balance performance through forced symmetry of the pairs FTP version offers maximum Coupling Attenuation for optimal EMI protection Performance protection during installation Exceeds current Category 6 requirements Nexans Cabling Solutions, Jan 2004 19 Class E Solution -6 SNAP-IN RANGE • Fully modular outlets and patch panels • Unscreened, Screened, Shielded Nexans Cabling Solutions, Jan 2004 20 Class E Solution -6 Cross-talk Cancellation Nexans Cabling Solutions, Jan 2004 21 Cat 6 v Class E Class E important for end-to-end transmission path BUT…. can be achieved with non compliant components relies on headroom in some areas to counter failure in others relies on typical ‘installations’ 2 connectors typical lengths - can have problems with long or short links Nexans Cabling Solutions, Jan 2004 22 Cat 6 v Class E Full Category 6 allows full flexibility now OR in future 4 connector channels may want to add cross connect or change configuration in future no problems with short or long links Why risk a ‘future proof’ solution by choosing Class E only? Choose Category 6 AND Class E to guarantee future compliance Nexans Cabling Solutions, Jan 2004 23 Attenuation to Crosstalk Ratio PS ACR CSE Channel performance - 2 connectors 70 dB CSE Channel performance - 4 connectors 60 dB ISO/IEC JTC 1/SC 25/WG 3 N568 specification 50 dB 40 dB 7.4 dB 30 dB 11.5 dB 20 dB 10 dB 20 40 60 80 100 120 140 160 180 200 Nexans Cabling Solutions, Frequency (MHz) Jan 2004 24 Total Capability Nexans is one of the only cabling companies that designs and controls manufacture of all components used. Nexans Cabling Solutions, Jan 2004 25 Class F Solution 7 Nexans Cabling Solutions, Jan 2004 26 Class F Solution Class F / Category 7 extend channel bandwidths up to 600MHz chosen interface is RJ45 based, providing full backward compatibility supported over STP the ACR (attenuation to crosstalk ratio) should be positive at 600MHz Nexans Cabling Solutions, Jan 2004 27 Class F Solution Nexans Class F response Guaranteed bandwidth of 600 MHz 4 pairs individually screened, 23AWG, 100 Ohm Extremely high NEXT and FEXT values Coupling Attenuation higher than 80 dB for optimal EMI protection Exceeds current Category 7 requirements LANmark 7 cable Nexans Cabling Solutions, Jan 2004 28 Fully Standardised Cat 7 is a fully ratified standard Component Standards : IEC 60603-7-7 (backwards-compatible) Ratification on 22.3.02 System Standard – Class F ISO/IEC 11801:2002 Ratification in August 09/02 Nexans Cabling Solutions, Jan 2004 29 Class F Markets Class F systems best suited for Very long life time of cabling infrastructure Very high replacement cost of cabling > 15 years Ships, Oil rigs, Hospitals, ... Mixed applications Shared digital/analogue use Multiple applications at same time Special ultra high bandwidth performance Nexans Cabling Solutions, Jan 2004 30 Class F and Multimedia Refers not to a “new” application, but on integration integrate existing applications in a shared media “1 solution fits all “ Nexans Cabling Solutions, Jan 2004 31 Application sharing Application sharing refers to the ability of a link to run multiple applications on the same time Number of applications depends on the amount of wires used by an application e.g. Fast Ethernet data 2 pairs Gigabit Ethernet data 4 pairs Voice 1 pair Fax 1 pair Video / CaTV 1 pair Cat 7 avoids possibility of x-talk between applications Cat 7 provides high bandwidth/pair for CaTV applications Nexans Cabling Solutions, Jan 2004 32 New Data applications Recent development in standardisation for applications 1 GBase TX2: Gigabit Ethernet over Class F 1 GBase TX4 Gigabit Ethernet over Class F New working groups for 10 Gigabit Ethernet over Copper working groups started in 11/2002 10GBase-CX4 – 15m 10GBase-T (100m) Target date for publication 2006 Nexans Cabling Solutions, Jan 2004 33 RJ45 or GG45 RJ45 originally designed for voice Pushed to extreme - stops at Cat 6 New Interface starts at 600MHz GG45 Fully Standardised IEC 60603-7-7 GG45 was selected as ‘preferred’ connector due to backwards compatibility Nexans Cabling Solutions, Jan 2004 34 Backwards compatibility Means RJ45 compatible Mechanically accepts RJ45 Electrically supports Cat 5e & Cat 6 Benefits Can utilise existing equipment Active, PC NIC’s etc Only need special cords when required Nexans Cabling Solutions, Jan 2004 35 Nexans GG45 8 contacts 100% RJ45 compatibile Switchmechanism Only 8 contacts at a time 4 Pairs on top 250 MHz 2 Pairs on top 2 Pairs on bottom 600 MHz 4 new contacts For 600 MHz Nexans Cabling Solutions, Jan 2004 36 GG45 plug A protruding part on the plug activates the switch in the jack Nexans Cabling Solutions, Jan 2004 37 LANmark-7 Core Products LANmark-7 GG45* Patch cords (No Hybrid-patch cords) LANmark-7 GG45* Snap In LANmark-7 STP AWG23 1000 MHz *GG45 is a registered trademark by Nexans Nexans Cabling Solutions, Jan 2004 38 Class F Solution ISO confirmed the Nexans proposal as the preferred Cat7 solution Prototypes have been submitted, independent testing (3P, Delta) confirms performance levels Nexans Cabling Solutions, Jan 2004 39 Class F Solution Category 7 Connector set Cross-sectional view in a high speed (Cat 7) configuration The protruding part of the plug opens the contacts of the switch. No signal will be put on the 2 upper central pairs of the GG45-jack, which are being grounded. Only the 4 extreme pairs transport the signals. Nexans Cabling Solutions, Jan 2004 40 Bandwitdh Limitations in Connectivity RJ45 stops here !!!! Nexans Cabling Solutions, Jan 2004 41 More LANmark-7 Products GG45 supports Application Sharing 4 Channels up to 1000 MHz each (when used as single pairs) Coming soon (Q2/2003): Splitter patchcords to connect to active equipment Nexans Cabling Solutions, Jan 2004 42 Field Testing Two Options: Network Analyser on Site Costly but accurate up to 600 MHz sample testing 5-10% Field Tester Measurement up to 300 MHz with Omnisanner II Test head 8262-47 “GG45 Class F Permanent Link adapter“ ISO Class F Link Limits Nexans Cabling Solutions, Jan 2004 43 Warranty Full LANmark Certified System Warranty Applications Any current or future application designed to be supported by a Class F channel as defined below Performance Class F Channel, Permanent Link and mated Connector requirements as specified in: ISO/IEC 11801 2nd Edition 2002* IEC 60603-7-7 / IEC 61076-3-110 Note : When tested using a Network Analyser. If tested using Level 3 field testers then performance is guaranteed to 300MHz. Refer to LANmark-7 GG45 Field Testing guideline Nexans Cabling Solutions, Jan 2004 44 Installation LANmark-7 requires some specialist installation knowledge Special certification is required for LANmark-7 Installation partner must have completed a special LANmark-7 training module Nexans Cabling Solutions, Jan 2004 45 LANmark-7 Summary “2 in 1” connector GG45 & RJ45 Cat 7 & Cat 6 Data & Multimedia Fully standardised Backward Compatible Application sharing Invest ‘just in time’ Only buy special cords when required Nexans Cabling Solutions, Jan 2004 46 Class D’02 ESSENTIAL range Snap-In connector Un / screened 110 or LSA termination, toolless Easy to install Compliant to TIA 568A-5 standard. Nexans Cabling Solutions, Jan 2004 47 Class D’02 ESSENTIAL range 19 inch 1 HU Patch panel High density Integrated cable fixing device Unscreened/screened LSA of 110 termination Nexans Cabling Solutions, Jan 2004 48 1 HU patch panel Rear connection High density cable guide tie wrap support LSA+ or 110 termination Nexans Cabling Solutions, Jan 2004 49 Product Range Modular Snap-in Patch Panels 24 port 1HU empty panel for modular ‘snap-in’ connectors versions with & without ‘clip-on’ strain relief Only ‘LANmark’ branded at present but suitable for essential snap-in connectors Nexans Cabling Solutions, Jan 2004 50 Class D’02 Essential range Certificate to download from the web. Nexans Cabling Solutions, Jan 2004 51 e warranty ssential range 15 year Link certificate downloadable file from the internet initially available on request Link Class D’02 ISO/IEC 11801 2002 Nexans Cabling Solutions, Jan 2004 52 Category 3 Nexans Cabling Solutions, Jan 2004 53 Category 3 Patch panel UTP Cat 3 patch panel 1 HU High density (50 RJ45 ports) LSA+ / 110 contacts Easy cable management for multi pairs or 4 pairs cable Numbering: - Top row (1-25) - Bottom row (26 – 50) - Square for patch panels labeling 2 pairs per RJ45(Pins 5,4 and 3,6) 1 Termination tool per patch panel Supplied with cage nuts and screws Nexans Cabling Solutions, Jan 2004 54 System Parts : IDC modules OMEGA IDC modules and frames 3 HU IDC distribution frame IDC frame houses up to 15 disconnection blocks 1 disconnection block terminates 10 pairs Front side connection One single tool Nexans Cabling Solutions, Jan 2004 55 System Parts : IDC modules Very High Speed Multimedia Patchcords Superior Category 5 specifications Moulded connectors RJ45 - RJ45, RJ45 - IDC IDC - IDC Nexans Cabling Solutions, Jan 2004 56 System Parts : cabinets QUICK MOUNT Delivered in 6 separate parts Maximum 45 kg / part 148 kg when completely mounted Mounting within a few minutes Automatic earthing Nexans Cabling Solutions, Jan 2004 57 System Parts : cabinets Patented New door handle with standard Eurolock included IP 20 (extendable to IP 33 using additional roof) 800 x 800 mm Accessories available Nexans Cabling Solutions, Jan 2004 58 Cabinets: AC-line Attractively styled : AC line central glass window Fully equipped With fixed or swing frames Different heights available (42, 36, 18, 12) Footprint : 800x 800 or 800x600 mm Wall mountable cabinets available Accessories available Open frames Nexans Cabling Solutions, Jan 2004 59 Warranty Policy 1. The SCOPE of our Certified System Warranty 2. How to apply for the Certified System Warranty ? Nexans Cabling Solutions, Jan 2004 60 Warranty Policy Product Warranty Performance Warranty CERTIFIED SYSTEM WARRANTY POLICY Application Warranty Labour Warranty Nexans Cabling Solutions, Jan 2004 61 Warranty Policy PRODUCT WARRANTY Valid for 20 years Valid for all Nexans Cabling Systems cabling elements, except active components Immediate replacement for production faults and product defects appearing : at the delivery during the installation during the exploitation Nexans Cabling Solutions, Jan 2004 62 Warranty Policy CHANNEL or LINK PERFORMANCE WARRANTY Guarantees excellent performances for links and channels (noise control). Channel Warranty if Nexans LANmark Cable, Connectivity and Patchcords are used Nexans Warranted Systems are guaranteed to exceed the performance criteria of the ISO/IEC 11801 last edition of 2002 Nexans Cabling Solutions, Jan 2004 63 CHANNEL or LINK PERFORMANCE WARRANTY Class D standards have changed substantially: ISO CLASS D limits for link in 1995 were 24 dB ISO CLASS D limits for link in 1999 were 29.3 db => headroom of 10 dB => headroom of 6 dB ISO CLASS D limits for link in 2002 are 32.3 dB = > headroom of 2 dB Nexans Cabling Solutions, Jan 2004 64 LANmark Class D Nexans have always promoted ‘enhanced’ solutions using ‘enhanced’ components Evolution in standards means some competitor offers using basic components will not comply with future standards Nexans LANmark Class D systems will exceed 2002 edition also justifying the need for superior enhanced systems using enhanced 5e cables Nexans Cabling Solutions, Jan 2004 65 Warranty Policy APPLICATION WARRANTY Nexans LANmark Class E and D Systems are warranted to support any current or future application 10 baseT Ethernet 100 baseT Fast Ethernet 1000 baseT Gigabit Ethernet 155 Mbit ATM Nexans Cabling Solutions, Jan 2004 66 Warranty Policy WHY A PERFORMANCE AND AN APPLICATION WARRANTY? Some competitors only guarantee ‘Cabling performance’ with no guarantee of the applications you may run Some competitors only guarantee ‘Applications’ but what happens when a new application emerges Nexans offers both Nexans Cabling Solutions, Jan 2004 67 Warranty Policy LABOUR WARRANTY Nexans will pay the labour cost to replace and/or install the defective components If installation done by an Nexans CSI For installations with LANmark 5 and 6 connectivity and cables Nexans Cabling Solutions, Jan 2004 68 Why use LANmark-5 Cable Average NEXT Competitor 'v' LANmark-5 0 20 40 60 80 100 120 Class D 95 dBs Class D 99 Class D 2002 Link using LANmark-5 components Link using Competitor 5e plus components Mhz Nexans Cabling Solutions, Jan 2004 69 Warranty Policy 1. The SCOPE of our Certified System Warranty 2. How to apply for the Certified System Warranty ? Nexans Cabling Solutions, Jan 2004 70 Warranty Policy CERTIFICATION DESIGN (BOM) CHECKLIST TEST RESULTS AP/132-677 INSTALLER’S ID Nexans Cabling Solutions, Jan 2004 71 Warranty Policy Nexans Warranty Direct Nexans warranty to End User Full end to end channel supported under worst case conditions Parts and labour (if installed by CSI and if LANmark components) Performance and applications guaranteed Clear & simple - no ambiguity or small print Will cover all media types in single document 20 year Nexans Cabling Solutions, Jan 2004 72 Warranty Summary A Nexans Certified System Warranty offers: Guaranteed Parts Guaranteed Labour Guaranteed Channel Performance Guaranteed Application Support Guaranteed Quality of Service Providing performance reliability value for money Nexans Cabling Solutions, Jan 2004 73 Warranty Policy The solution: A system with a Product, Performance, Application and Labour warranty CERTIFIED SYSTEM WARRANTY POLICY Product Application Performance Labour Nexans Cabling Solutions, Jan 2004 74