John Deere 50 & 60 Series Combine Calibration This reference guide outlines the calibration process for the Harvest Doc yield monitoring system found in John Deere 50 & 60 series combines and will not satisfy calibration requirement for 70 series or S-Series combines. The accuracy of the calibration and grain thrashing system settings will determine the accuracy of the yield data. Please refer to combine pre-harvest recommendations and inspect equipment as recommended. Before calibrating, ensure the combine grain tank and unload auger are empty. NOTE: For specific procedures on yield monitor calibration, refer to the combines Operator’s Manual. This document has been developed as a quick reference guide and may not include information that has been updated since its development. Because there are various types of yield monitor systems, verify which is installed and the required calibration procedures associated with that system. Standard Calibration Procedure 1. Select the Original GreenStar Monitor button if accessing through a GS2 or GS3 Display. If using and Original Display begin at Step 2. 2. Select Setup, then the Harvest Monitor (A) button. 3. Select the Yield Calibration (D) button. 4. Select the Standard Calibration Mode (B) button. Once you are ready to harvest, press Start © and begin harvesting Best Practice: Operate your machine at full capacity on reasonable level ground and in uniform yield crop. Example: 5 mph 5. After harvesting 3,000 – 5,000 pounds of crop, stop the combine and allow all harvested grain to enter the grain tank. 6. Select Stop (C) to stop the calibration. Record the current calibration factor, date/time, and harvested weight. NOTE: Until calibration sample load is weighed, the operator may continue to harvest and then return to this screen to enter the weight value. 7. Weigh the harvested grain and enter the Scale Weight (E). Record the scale measured weight and new calibration factor. Low Flow Calibration Process NOTE: The Following steps should only be performed after a Standard Calibration procedure has been successfully completed. 1. From the Setup menu, select the Low Flow (B) calibration mode. 2. Once ready to harvest press Start (C) and begin harvesting. NOTE: Operate the machine at 1/2 to 2/3 the ground speed of your standard calibration on reasonably level ground and of uniform yield. 3. Adjust harvest speed until the indicator on the Mass Flow is within the target change. 4. After harvesting 3,000 – 5,000 pounds of crop, stop the combine and allow all harvesting grain to enter the grain tank. 5. Select Stop (C) to stop calibration. 6. Weigh the harvested grain and enter the Scale Weight (E). The monitor will adjust the Flow Comp Number for low flow harvesting. Harvest Monitor Moisture Correction High moisture crop requires a moisture calibration. The following steps should be followed to adjust your combine’s moisture settings to match an elevator moisture reading. A moisture reading can be captured from the home page load total. 1. From the Harvest Monitor setup page, select Moisture (E). 2. Select Moisture Correction (A) 3. Enter the correct Moisture Correction (C) +/_ to match the elevator reading. 4. Select the Home button.