F4 Overview Presentation

advertisement
Series F4S and F4D
1/4 DIN Ramping Controllers
1
2
Watlow’s Next
Generation Styling
Series V4T 1/4 DIN
Temperature Controller
Series 97 Matching
1/16 DIN Limit
Controller
Series F4S and F4D
Ramping Controller
3
F4 Ramping Controllers
 F4S
Single Channel Ramping
Single
channel temperature or process
control with profile capability
 F4D
Dual Channel Ramping
Allows
temperature and humidity control in
one package
4
What Is a Ramping Controller?
Output follows a set of user instructions (profile),
to automatically adjust or hold set point for
different time periods.
Temperature
250
150
80
75
Time
5
Ramping or Fixed Set Point Operation
 Ramp
and Soak Programmable Control
 Control
operation automatically follows a set (profile)
of preprogrammed instruction to perform a
processing task.
 Static Set
Point Control
 Operator
intervention is required when processing
changes are needed.
6
F4 Ramping Controller
Focus Markets
7
Environmental
Chambers

Applications
Product thermal
cycling
 Laboratory
chambers
 Product analysis
 Product storage

8
Furnace
and Oven

Applications
Heat Treating
 Kilns
 Autoclaves
 Foundry & Metal
Processing

9
Electronic
Components
and Assembly


Semiconductor
processing
equipment
Electronic assembly
equipment
10
Other Focus
Industries

Applications
Analytical
Instruments
 Glass
Manufacturing and
Annealing
 Incubators

11
Ease of Use
The most important
selection factor
following quality and
reliability when
selecting a temperature
controller is
ease of use.
Source:1997 VDC Worldwide
Market Report for Industrial
Electronic Temperature Controllers
12
Enhanced Display and Keypad
Ramping control
programming made easy
through advanced technology
 Icons
for international applications
 Read-at-a-glance process display
 Full message prompting
of operation and setup
13
F4 Operator Interface
 Primary
process display
 Large 5-digit, 7-segment
displays
0.562”
(14.3mm) display digit height
F or C, Degree, and decimal point indication
 Operations display
4
line X 20 characters per line
 High definition back lit LCD
Wide
viewing angle
14
F4 Operator Interface
6
operator interface keys
 Rubber
4
key switch with tactile feel
navigational keys
 Parameter
and value selection with arrow keys
 “i” information key
Toggle for Help
 Profile key - initiate or hold profile operation
15
F4 Operator Interface
 Discrete
LED indicators
 Control
output indication
 Alarm active indication
 Communications activity
 Profile indication
16
Multilingual Prompts

Available in multiple
languages:
English
 German
 French
 Spanish

17
Advanced Hardware
Features




20 MHz operation, 16-bit
processor
NEMA 4X sealed front panel
Shallow 4” (101mm) overall
case depth
FLASH memory for field
software update
18
F4 Industrial Design Features
 High strength injection molded case
 3.85
“ (97.8 mm) behind panel depth
 Ergonomic design styling
 Compatible
 NEMA 4X
with Series 96 & 97 limit
front panel seal
 Convenient
4 screw installation brackets
19
F4 Industrial Design Features
 Touch safe
wiring termination
 Removable
for wiring convenience
 Accepts 12 to 22 gauge wires
 Positive latching feature for
connection integrity
20
Loaded With Standard
Hardware Features

3 universal analog inputs
(2 & 3 optional on F4S)



TC, RTD, process (no DIP switches)
4 digital inputs (standard)
Eight digital outputs (standard)


Programmable events
Chamber heat & cool control
functions
21
Modular Hardware Inputs and Outputs


Field replaceable input and
output modules
Dual control outputs

Heat or cool or Off
 Linear
or time proportioned
 Switched dc/open collector,
SSR, process

Alarms (2 standard)

Process or deviation
2
A mechanical relays
22
Leading the Way in Communications

Serial communications
standard
 EIA 232
& EIA 485
hardware interfaces
 MODBUS
protocol
 9600 and 19,200 baud

Allows controller
software updates in field
23
Hardware Features

Retransmit outputs
2 optional
 Current or voltage
 Process, set points,
% power


Universal power supply


85 to 265 vac/vdc, 50 to 60 Hz
Optional 24 to 28 vac/vdc
24
Performance Specifications

Operating range


Calibration accuracy


0 to +55 C
0.1% of span, +/- LSD
(whole digit)
Sensor update rate

20 Hz, 50 milliseconds,
channel 1
25
F4 Hardware Architecture
Input to Output Isolation
Minimum
500 Vac/Vdc
between blocks
26
Agency Approvals

UL, c-UL 916 listed


User replaceable input and output
modules
European CE conformity
EN 50082-2, immunity standard
 EN 50081-2, emission standard
 EN 61010-1 low-voltage
directive, safety


NEMA 4X, IP 65 front panel seal
27
Accurate Timing
of Profiles

Real time clock
 +/-

92 seconds/month
Lithium battery
7
year shelf life
28
Software Architecture
Main Page
Operations Page
Profile Page
Setup Page
Factory Page
29
Software Architecture

“Guided” setup & programming
 Guided
configuration
Presents
a sequence of parameter
choices needed to complete a
functional configuration
 Full
unabbreviated text
Uses
full text messages, not cryptic
parameter and configuration names
30
Software
Architecture

Context
sensitive help
Toggle the
“Information”
key
31
Programming
An Autostart
Step
Set F4 Controller
to Start Profile at
4:30 AM on
Monday
32
Programming
An Autostart
Step
33
Programming
An Autostart
Step
34
Programming
An Autostart
Step
35
Programming
An Autostart
Step
36
Programming
An Autostart
Step
37
Programming
An Autostart
Step
38
Programming
An Autostart
Step
Use “i” Key for
More Information
39
Programming
An Autostart
Step
40
Programming
An Autostart
Step
Save Change,
Autostart Setup
Complete
41
F4 Software Architecture
 Function Naming
 Optional, up
Better
to 10 Characters
operator recognition
Enter Alarm Name:
Alarm 1
Adjusts Character
Selects Character
42
F4 Software Architecture
 Pop Up
Displays
 Lets
the user know when the F4 software is
storing changes in Non Volatile Memory
Save Setup Changes
or restore Values?
Restore
Save
43
F4 Main Page
Main Page____
Go to Operations
Go to Setup
Go to Factory
Main Page
Display key
Up
control parameters
to 16 customer programmable control parameters
Set
points, alarms, errors, % power
Profile operational information
Inner loop set point (cascade control)
Gateway to
controller configuration
44
F4 Operations Page
Main Page____
>Go to Operations
Go to Setup
Go to Factory
Operations Page
 Auto tune PID
control parameter values
 Edit PID
Alarm
set points
45
F4 Profiles Page
Profile Page
Main Page____
Go to Operations
>Go to Profiles
Go to Setup
Create
profiles
Edit profiles
Delete profiles
Rename profiles
Embedded Mil-Std 810
46
F4 Set Up Page
Setup Page
System
Main Page____
Go to Operations
>Go to Setup
Go to Factory
Settings
GSD,
Clock, PID Units, F or C, Auto Tune SP, Sensor
Failure, Open Loop, Power Out Action
Inputs; Analog
and Digital
Outputs; Control, Digital, Alarm, Comms, Retrans
Custom main page; Selections
47
F4 Factory Page
Factory Page
Set
Lockout
Change
Main Page____
Go to Operations
Go to Setup
>Go to Factory
password
Diagnostics
Date
code, software revisions, diagnostic tests
Calibration data
48
F4 Profile Operation
 Up to
40 flexible length profiles
Optional naming
256
total steps (segments)
Six step types
Ramp Time/ Rate (single channel only)
Soak, Auto Start, Jump, End
49
F4 Profile Operation

Wait For feature
 Programmable
in ramp/soak type steps
 Digital
inputs configured as wait for events
Named choices are displayed
 Analog inputs (1 - 3)
 Step
time starts when Wait For is met
50
F4 Profile Operation

Event output feature
 Programmable
in ramp/soak type steps
 Digital
outputs configured as events
Named choices are displayed

Manually adjustable
 Static
set point mode or while profile is on hold
 As a selection for the main page
51
F4 Profile Operation

Guaranteed Soak feature
 Programmable
in ramp/soak type steps
 Guaranteed
soak band set in the system menu
 Profile time pauses when process value goes
outside of the soak band
52
F4 Profile Operation
 Power
outage recovery feature
 Programmable
in the system menu
Power
outage time
Power outage action
Continue profile
Hold profile
Terminate profile
Reset profile
Go to idle set point (maintain event outputs)
53
F4 Ramping Control Operation
 Heat
and cool PID
 5 PID sets per channel
Profile
step selectable
 Cascade operation
Channel 1
 Process or Deviation
 Input 1 = Inner Loop
 Input 3 = Outer Loop
54
F4 Ramping Control Operation
Channel 2
humidity control
Vaisala
& Rotronic non-temperature compensated
Wet /Dry bulb control
Any sensor type
Rotating process displays
Set
up menu choice
Alternately display any or all of the three
 Analog input process values
55
F4 Digital Input Operation
 Four digital inputs
 Programmable
wait for events
Namable
 Front
panel lockout
 Reset alarms
 Turn outputs OFF
 Start, pause or terminate a profile
56
F4 Digital Output Operation
 Eight Digital Outputs
Programmable as event outputs, namable
Manual or profile selectable
 Optional Function DO5 = Complementary Output
 Optional Function DO6 = Boost Heat
 Optional Function DO7 = Boost Cool
 Optional Function DO8 = Compressor Control

57
F4 Digital Output Operation
 Digital Output 5
Selection
 Complementary output
Operates
in conjunction with Channel 1
Control outputs
Selectable to complement time proportioned outputs only
Output 1A = ON/CLOSED
DO5 = OFF
58
F4 Digital Output Operation
 Digital Output 6
 On/Off control
Operates
 Boost
Selection = Boost Heat
of auxiliary heat source
based on Channel 1 percent power demand
heat % power level
Power
level at which boost delay time starts
 5% hysteresis
 Boost
delay
Minimum
time that the boost power level is exceeded
before boost is enabled
59
F4 Digital Output Operation
100 %
85%
Digital Output #6 Boost Heat
Boost Percent
Power = 85 %
Heat %
Power
0%
Time in Seconds
On
Boost Delay Time
= 30 Seconds
Off
Boost Heater
60
F4 Digital Output Operation
 Digital Output 7
 On/Off control
Operates
 Boost
Selection = Boost Cool
of auxiliary cool source
based on Channel 1 % power demand
cool % power level
Power
level at which boost delay time starts
5% hysteresis
 Boost
delay
Minimum
time that the boost power level is exceeded
before boost is enabled
61
F4 Digital Output Operation
 Digital Output 8
 On/Off control
Selection = Compressor
of refrigerant compressor
Operates
based on Channel 1 percent power demand
Compressor ON/Off percent power level 100% to -100 %
 Compressor OFF
Cool
delay in seconds
power demand no longer exceeded for this time delay
 Compressor
Delay
ON delay
in seconds before compressor will restart
62
F4 Digital Output Operation
100%
Digital Output #8
Compressor off %
Power = 2 %
Compressor on %
Power = 0 %
2%
0%
Time in Seconds
- 100%
%Power
Compressor On Delay
= 45 Seconds
On
Off
Compressor
Compressor off Delay
= 20 Seconds
63
F4 Ramping Control Operation
Main Page
Additional displayable functions when running a
profile
Current
file, current step, step type
Channel target set points, step time remaining
Wait for status, event output status, event input status
Last jump step, jump count
16 displayable parameters total
64
Creating a Part Number - F4S
Single Channel Ramping Controller
F4S X - X X X A - X X X X
Power Supply
RG Displays
Custom Options
Output 1A
Output 1B
Auxiliary Input
Language Option
English, German
Spanish, French
Auxiliary Retransmit
65
Creating a Part Number - F4D
Dual Channel Ramping Controller
F4D X - X X X A - X X X X
Power Supply
Output 1A
Output 1B
Output 2A
Output 2B
RG Displays
Custom Options
Language Option
English, German
Spanish, French
Auxiliary Retransmit
66
F4S and F4D Feature Summary
F4S single channel
Single channel PID
controller
 1 universal analog input
 4 digital event inputs
 EIA232/485 comms
 8 digital event outputs
 2 alarm outputs
 40 files, 256 steps

F4D dual channel
Dual channel PID
controller
 3 universal analog inputs
 4 digital event inputs
 EIA232/485 comms
 8 digital event outputs
 2 alarm outputs
 40 files, 256 steps

67
Reasons to Buy

Usability
 High
definition
display
 Information key
 Guided set up
and programming
68
Reasons to Buy

Reliability
 ISO
9001
manufacturing
 Three year warranty
 Year 2000 compliant
69
Reasons to Buy

Performance
 Control
accuracy
 Extensive feature set
 Exhaustive life &
qualification testing

Availability
4
day lead-time
70
Reasons to Buy

Support
 Local
sales
specialists
 Applications
engineering
support
 Rapid field
returns department
71
Series F4S and F4D
1/4 DIN Ramping Controllers
72
Download