EA900II 3/3 UPS Introduction 10KVA-120KVA 1/18 EA900II 3/3 UPS Introduction ☞ Power range: 10-120KVA ☞ Working mode: Intelligent on-line(3/3) ☞ Applications: Mini/media data center ☞ Certification: CE 2/18 System Topology Bypass_R Bypass_S Bypass_T Bypass_N Main_R Main_S Main_T Main_N 3/18 BAT+ OP_R OP_S BAT- OP_T OP_N Charger Circuit Topology BUCK+CT+ 2 3 4 1 BUCK+CT- C 1 6 E3 2 2 5 Q8 1 2 SLA50120 Q1 G 1 BAT+OP 2 1 3 1 + 70TPS12APBF 3 1 J10 Q3 RHRG75120 100uF 2 2 J9 NEUTRAL 1 D2 1 1 + 70TPS12APBF Q4 RHRG75120 G 3 2 2 100uF D1 3 SLA50120 BAT-OP Q7 1 C BAT+V+ BAT+V- BAT-IP BAT-V+ BAT-V- J5 New 1 2 3 4 5 6 J6 New NEUTRAL BUS-IP BUS-IP.V+ BUS-IP.V- 2 NEUTRAL NEUTRAL 3 4 BAT+IP New 1 2 3 4 5 6 1 1 2 3 4 5 6 5 2 New Q2 J15 J16 BUCK-CTBUCK-CT+ 4/18 CD293 6 2 3E 1 1 2 3 4 5 6 BUS+IP NEUTRAL BUS+IP.V+ BUS+IP.V- 1 1 2 J11 New 1 2 3 4 5 6 New CHGR+.V NEUTRAL CHGR+CAPV+ CHGR+CAPV- 1 2 3 4 5 6 NEUTRAL CHGR.VCHGR-CAPV+ CHGR-CAPV- Whole Structure (10-30KVA) 5/18 Whole Structure (40-60KVA) 6/18 Whole Structure (80-120KVA) 7/18 Unit Pictures 8/18 Inbuilt Battery Model Backup Time 10K Half resistance load with 32*9AH battery: 15 minutes 28 seconds Full resistance load with 32*9AH battery: 6 minutes 09 seconds Half resistance load with 64*9AH battery: 37 minutes 39 seconds Full resistance load with 64*9AH battery: 18 minutes 07 seconds 20K Half resistance load with 64*9AH battery: 18 minutes 02 seconds Full resistance load with 64*9AH battery: 5 minutes 38 seconds 30K Half resistance load with 64*9AH battery: 8 minutes 59 seconds Full resistance load with 64*9AH battery: 2 minutes 42 seconds 9/18 Reliability Adopt the global top brand: USA TI Chip, INFINEON IGBT, SCR Independent duct design 10/18 Imported dust filter Green Energy Saving Input with PFC; Input PF>0.99; Input THDI<3%; Efficiency>93% 11/18 Intelligent Battery Management Battery settable from 30~40pcs Battery self -test 12/18 Intelligent three stage charger Battery compensation management Intelligent Monitor Management Man-machine-dialog; 5.7inche large screen;10,000 history log query 13/18 14/18 Convenient Maintenance EA900II 3/3 series ups adopt modular design, the power modular support to hot swap exchange, it is more convenient to maintenance than the traditional ups. Reduce the maintenance time, improving the system reliability. Support hot swap exchange 15/18 Parallel Introduction UPS1 UPS2 UPS n(n≤6) Paralleled port Parallel communication cable Note: 1) Each cabinet digit number needs to be set through the LCD screen; 2) Cable length difference between the output of each UPS to the output PDU should not exceed 10% ; 3) UPS can share the battery pack or not. Parallel system Wiring diagram 16/18 Specification Power supply mode: 3 phases input /3 phases output; Input PF: >0.99; Input THDI: <3%; Output PF: 0.9; Efficiency: on-line: >93%; Parallel redundancy: Up to 6 units, can share battery group; Rate DC input: ±192DC (12V32pcs, support settable from 30-40pcs); Charger current: 10-30KVA: 12A; 40-80KVA: 24A; 100-120KVA: 48A; BAT.LOW warning: 11VDC* Battery quantity, EOD:10.2VDC* Battery quantity Cabinet color: Black 17/18 Standard and option configuration Function description Standard Option RS232, RS485, USB; √ Dry contact 7 output dry contact” inverter output, AC failure, Over load, bypass output, system fault, BAT. Low. system warnings; 2input dry contact: remote EPO, battery breaker status or generator connecting in. √ SNMP Card SNMP Card: Internal & external √ Protection the ups from Surge √ Collect external battery temperature, UPS adjust the charger output voltage automatically √ Parallel components Realized the function from single to parallel √ Battery breaker The breaker between ups and battery group √ Transformer 10-60KVA support inbuilt output transformer √ Communication port SPD Bat. Temp. testing port 18/18