Technical Specifications are as under:-
1. Advanced technology ventilator suitable for ventilating pediatric
patients of all age groups. Should be user-friendly & have sturdy
design.
2. Should have facility for invasive and noninvasive ventilation.
3. Multi microprocessor controlled system with individual selection of
various ventilation parameters & PEEP.
4. The system should have the facility for both Pressure triggering &
Flow triggering
5. Should have the following modes of ventilation:










Assist/Control
Volume Control
Pressure Control
Pressure Regulated Volume Control with on demand flow.
Pressure support with back-up ventilation
SIMV ( Pressure Control ) + Pressure Support
SIMV (PRVC) + Pressure Support.
PEEP
NIV(non invasive ventilation ) BIPAP& CPAP
Apnea Ventilation
6. The system should have the following parameters:
1.
Tidal Volume:
10 ml – 350 ml
CMV
2. Frequency:
Infant:
4 – 100 breaths / min
3.
1 – 60 breaths / min
4.
10% - 80% of breath cycle time
5.
0 - 30% of breath cycle time
6.
0 – 80 cmH2O
7.
0 – 50 cm H2O
SIMV frequency
Inspiratory time
Pause time
Pressure level
PEEP
8.
Inspiratory rise time
0 - 20% of breath cycle time
I : E ratio
2 : 10 – 4 : 1
7. Should be available with important audio visual alarms like High
Breath Rate, Low Minute Volume, Apnea, Low battery, Low PEEP,
Gas Failure etc.
8. The display panel must simultaneously display important parameters
like PIP, PEEP, FIO2, I:E, MAP, Mode of ventilation, RR.
9. Should have separate user interface & ventilation unit for flexible
positioning around the patient.
10. Machine should have automatic calibration for oxygen sensors.
11. Should have built-in battery back-up for at least 60 minutes.
12. Unit should have Humidifier



Servo controlled heated respiratory humidifier.
Temperature of delivered gas on LED display.
Temperature should be adjustable
Jar should be autoclavable.
13. Temperature with heated wire in the tubings supplied as a standard
accessory with temperature variable and variable/ adjustable relative
humidity.
14. Compressor should be of compressor based technology, same company
make mounted on ventilator Trolley.
15. Unit should have reusable ultrasonic integrated nebulizer.
16. Should have touch color screen TFT display of at least 10 inches for
display of wave forms & loops for each breath.
 Access through touch screen & main rotary dial
 Direct access to vital settings: PEEP, O2 concentration, Respiratory
rate & Volume (or Pressure)

24 hour trend display of up to all parameters.
17. Should be supplied with following standard accessories


Mounting unit with trolley
Reusable Humidifier chamber – 2jars/ chamber&2 temperature probes
Mask and nasal prongs of different sizes 10 in each size for non
invasive ventilation.
18. Should work with double limb patient circuit both reusable and
disposable kinds. At least three sets of reusable pediatric breathing
circuits and thirty set of pediatric disposable circuits should be
supplied with the system. Circuits should have water trap in both
inspiratory and expiratory limb.
19. Should have two no.single piece autoclavable interchangeable
expiratory cassette/valve of at least 3 years life.For highly infectious
patients should supply 20 disposable expiratory valve.
20. Ventilator should have patient proximal Flow measurement i.e. at the
Y piece.Machine should be supplied with 10 flow sensor.
21. Should have permanent oxygen sensor doesn’t need replacement or
calibration otherwise the O2 cell should be provided free of cost during
the warranty and CMC period.
22. Should have facility for ventilation data transfer & network connection
23. Should be CE certified and FDA approved.
24. Should have two years warranty and five years CMC should be quoted.
25. The rates of spares and consumables that are not covered in
warranty/CMC must be quoted and their availability must be ensured
till five years after the expiry of warranty. The firm should give a
certificate to this effect.
26. The firm should furnish a dealership certificate from the manufacturer.
27. The firm should give a certificate that they have not been blacklisted
by any govt. institution and they have not supplied the equipment at a
lower rate to any govt. institution.
28. Principle company should have service centre in Delhi with adequate
infrastructure
29. Performance report from three Government/Corporate hospitals should
be submitted.
30. Should be provided with compatible CVT and UPS.