CATIA Foils v5 - CADAM Drafting

advertisement
Windows Installation
Tips and Techniques for CCD
and CATIA V5
SUBJECT: Using CCD to migrate from other CADAM-like systems to CATIA V5 on Windows
NAME: Pierre Devaux for Ozzie Marquez
October 4, 2000
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
(SYS-8)
Windows Installation Tips and Techniques for CCD & CATIA V5 200010041
AGENDA
MIGRATION PLAN
 OS AND HARDWARE REQUIREMENTS
 CCD ENHANCEMENTS
 WINDOWS NT INSTALLATION AND
CONFIGURATION TIPS
 DATABASE MIGRATION
 ON-LINE DOCUMENTATION
 ADMINISTRATOR TIPS
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 LICENSING AND PLOTTING
Windows Installation Tips and Techniques for CCD & CATIA V5 200010042
OS and HARDWARE REQUIREMENTS
 CATIA-CADAM DRAFTING (CCD) SUPPORTS:
CCD V4
CCD V5R3
Windows NT 4.0 up to SP5
Windows NT 4.0 up to SP5
Windows 2000
Windows 98 & 95, Windows 2000 as of V5R4
 HARDWARE FOR A PRODUCTIVE SYSTEM:
 150 MHz CPU (or faster)
 2D graphics adapter with 2 Mb VRAM
 2 or 3 button mouse (3 preferred)
 17 inch SVGA monitor with .28 (or better) dot pitch
 Network adapter (required for licensing)
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 64 Mb of RAM (more if working with large raster models)
Windows Installation Tips and Techniques for CCD & CATIA V5 200010043
OS and HARDWARE REQUIREMENTS
 CATIA V5 SUPPORTS: Windows 95/98 and Windows
NT 4.0 SP5. Windows 2000 as of V5R4.
 HARDWARE FOR A 2D/3D PRODUCTIVE SYSTEM:
 400 MHz CPU (or faster)
 256 Mb of RAM (minimum)
 3D OpenGL graphics adapter with 1280 x 1024 resolution
 17 inch SVGA monitor with .28 (or better) dot pitch
 Network card (required for licensing)
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 3 button mouse
Windows Installation Tips and Techniques for CCD & CATIA V5 200010044
WINDOWS 2000
 New features available with Windows 2000 that
administrators should consider:
 Enhanced Security
 Disk Quotas
 Encryption
 Property Sets
 Link Tracking
 DFS
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Symbolic Linking
Windows Installation Tips and Techniques for CCD & CATIA V5 200010045
CCD ENHANCEMENTS
 CCD V423R1 Administration
 Windows 2000 support
 LUM 4.5.8 required for Windows 2000
 Automatic license release
 Administrators can now specify an idle time of 30 minutes or more before the session
license is released.
 Static binding for license clients
 Remote Plot Mode
 Drawings on remote host can now be plotted without having to file the model locally.
 Window Temp Plot Data
 New button TPD added to Plot Current. Plots what’s on the screen, like Buffer Plot
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 LUM 4.5.5 or above is required on the License Server.
 LUM does not have to be installed on the clients.
Windows Installation Tips and Techniques for CCD & CATIA V5 200010046
CCD ENHANCEMENTS
 CCD V423R1 Administration (con’t)
 Synchronization of remote format tables with CCD-NT
 CCD V5R5 Administration -- In addition to all the 423R1
enhancements, it includes:
 Advanced Mouse Button Functions (Windows only)
 Windows 95 (OSR2) support
 New character strokes
 Several new characters have been added to support Helix to CCD
migrations.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Right mouse button clicks can now perform several function key
operations.
Windows Installation Tips and Techniques for CCD & CATIA V5 200010047
CCD ENHANCEMENTS
CCD V5R5 Administration (con’t)
 CADEX is now available
 Requires a separate install
 A V4 type license is required
 IUE change
 Absoft ProFortran V6.2 is now certified (Windows only)
 MCX/Helix Translator
 New Web-based makup and annotation product (CADAM Web
Conference) is now available on www.cadam.com for a test
drive
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Helix Migration Package can be downloaded from www.cadam.com
Windows Installation Tips and Techniques for CCD & CATIA V5 200010048
INSTALLATION
 Remove all references to older CCD releases before
installing CCD V423 or V5
 Using Control Panel, remove the following environment
variables:




CCD_ROOT
OPGS_RUN_TIME
DXF_TMP
PDELIB_TMP
 Use a regular user to install CCD V423 or V5
 Installing CCD on Windows is very simple.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Also remove all references to the older CCD release directory
from the Path variable.
Windows Installation Tips and Techniques for CCD & CATIA V5 200010049
INSTALLATION
REGISTRY ENTRIES
 HKEY_LOCAL_MACHINE
SOFTWARE/
DASSAULT SYSTEMES/
CATIA-CADAM Drafting/
55.0/
»CCD_ROOT
»UserManuals
e:\ccdraft
e:\ccdraft\doc
 On Windows, if CCD is installed by the administrator, use
Regedt32 to change access to DASSAULT SYSTEMES. Give
everyone read access.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES




Windows Installation Tips and Techniques for CCD & CATIA V5 2000100410
INSTALLATION
 Code-serving versus installing on each client
 Code-serving advantages:
 Since the code is only installed on one system, code updates and administration is
centralized, therefore simpler.
 Ensures that everyone is running the same level of code.
 Recommended if network speeds are acceptable when invoking CCD or CATIA.
 If the code-serving machine goes down, everyone is down.
 On slow networks, for example, starting CCD (~10 Mb) or CATIA DR1 (~13 Mb) or CATIA
MD2 (~67 Mb) can take some time.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Code-serving disadvantages:
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100411
INSTALLATION
 Code-serving versus installing on each client (con’t)
 Client installation advantages:
 Improves application startup time. Specifically on Wide Area Networks (WAN).
 The user or administrator can run a local, customized version of CCD or CATIA.
 If the workstation uses a nodelocked license, the user can continue to run locally, even if
the database server is inaccessible.
 More difficult to administer and control in large installations.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Client installation disadvantages:
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100412
INSTALLATION
CLIENT CCD Shortcut
Create a CCD Shortcut on
each NT Client with the
following options:
Target: ccdraft <options>
-f (full screen)
Start in:
Name of directory CCD
should start in for
File/Open.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
-m (start-up model name)
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100413
LICENSING
LICENSING CCD
 Only IBM’s License Use Management (LUM) is
supported. The current version is 458.
 NT 4.0, Windows 2000 or UNIX (AIX, HP-UX, IRIX or Solaris) can
be a license server
 Install the new ccdnls.dll with static binding support on all CCD clients. This dll is
available from DSA’s FTP Site.
 LUM is free for all platforms and can be downloaded from:
http://www-4.ibm.com/software/is/lum/v4.5.html
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 You must install LUM on the server and at least on one client.
 After installing LUM on one client, move the Winnt\i4ls.ini file to all other clients.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100414
LICENSING
 LICENSING CCD V5
 LUM V4.5.5 or above is required, but LUM 458 is recommended.
 IBM generates two license certificates: One for CATIA V5 and the
other for CCD, even though CCD is an add-on product.
Ask for
product number 5691-CCD.
 CCD V5R5 comes with a 45 day full-function trial license.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 A valid CATIA V5 Configuration (DR1, MD1, ME2, etc.) must be
installed to run CCD V5.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100415
LICENSING
 LICENSING CCD V5 (con’t)
 CCD V4 HRAS (Hybrid Raster) and CADEX can be used with
CCD V5, but both require a V4 license.
© 1997 – 2000 DASSAULT SYSTEMES
 IUE and MCX are now included with Base CCD V5, therefore a
separate license for these products is not required. The Markup
and Annotation product is no longer available in V5.
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100416
PLOTTING
ON WINDOWS, CCD SUPPORTS:
 CGM, HPGL, HPGL/2 and PostScript
UNIX Scripts
Equivalent files on Windows
PLOT/plotscript_hp2
Plot\hpgl2.bat (runs the job)
PLOT/backend_hp2
Plot\hpgl2.def (PHIGS config)
PLOT/plotopts_hp2
Plot\hpgl2.opt (plot options)
Plotting is well documented in the CADAM Drafting
Installation Guide for Windows NT.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Other formats (see CCDraft\Plot\Samples\ps2tiff.bat)
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100417
PLOTTING
 Buffer plotting can be done by using the new
(Window TPD) button on Plot Current.
You can also use the Windows screen capture tools
or CCD’s clipboard feature.
 If you can print to a printer/plotter from Windows, then CCD
should also be able to plot to it. Just select Windows Printer as
the default plotter from CCD’s Plotter Setup menu.
 Only the plotopts file is customizable.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Windows Print Driver Support
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100418
MIGRATION PLAN
MF CADAM
MICRO CADAM
CADRA
Models
B
E
T
T
E
R
B
E
S
T
G
O
O
D
NURESTOR
DXF/DWG
IGES
Data Transfer
(UNIX)
PRO CADAM
Pre-V3R5
db_update model
names
C_/C_/C_xxx to
D_xxx
PRO CADAM
V3R5 or >
CCD -UNIX
models/symbols/formats
Rename
Model update
name only
D_xxx to xxx.cdd
Model update
D_xxx to xxx.cdd
Call and File models
CCD-V4 or V5 
DASSAULT SYSTEMES Information for Users Forum
CATIA V5 on Windows
© 1997 – 2000 DASSAULT SYSTEMES
MCXTRAN
Symbols
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100419
MIGRATION PLAN
 Backup all data before any changes are made!
 Archive MF CADAM models in NURESTOR format. Helix models
should be archived in either DMNDOS or OS File (.MCD) format.
Don’t forget the symbols, fonts, and formats (Helix models).
 It’s a good idea to store these files on CD-ROM.
 What CADAM Tables need to be migrated?
 Plotting
 What plotters and plot options will be used?
 If migrating from UNIX, save all the plotscripts. It will help you
when configuring plotting on Windows.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Symbols, Fonts, Special Characters, Plot Formats
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100420
MIGRATION PLAN
 CCD Data exchange options on Windows
 Access to MF CADAM’s database
 ICF is the only interactive option on NT to access the MF CADAM database.
 Starting with MVS OS390 V2.5, ICF will not work from Windows or UNIX to MF CADAM.
A special MVS IUCV fix is available from DSA to resolve this problem.
 Access to CCD UNIX database
 ICF (user is confined to the UNIX CADAM database, but can file to Windows. Must also
file locally to plot the model accessed on remote systems.)
 IMPORTANT: CCD (UNIX and Windows) releases should be the same.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 PCNFS (Warning: Unlike UNIX, Windows is not case sensitive)
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100421
MIGRATION PLAN
 CCD data exchange options on Windows (con’t)
 External File Translator (EFT)
 AutoCAD DXF and DWG format support.
 AutoCAD releases 11 - 14 are supported.
 Some model touch-up may be required.
 Best method of transferring data from CADAM-like systems (other than Helix) into CCD.
 Almost 100% translation in most cases.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 NURESTOR files can be imported/exported using the CCD Data
Transfer option on Windows.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100422
MIGRATION PLAN
 CCD data exchange options on Windows (con’t)
 Helix Migration Package (mcxtranv4)
The recommended method if migrating from MICRO CADAM or Helix to CCD.
Available from www.cadam.com.
Best translation method. Results are near 100%.
Unlike NURESTOR format, mcxtranv4 has no limitations such as model size or other
imposed restrictions by the older NURESTOR Mainframe CADAM format. What you
see in Helix is what you’ll see in CCD!
© 1997 – 2000 DASSAULT SYSTEMES




DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100423
MIGRATION PLAN
 UNIX CADPROF SETTINGS
 Document all current settings. The same settings can be used in
the CCD Cadprof utility on Windows. If migrating from Helix,
refer to the Helix Defaults to Cadprof Mapping document in the
Helix Migration Package.
 Use it as a guideline to help you design user database access
permissions on Windows NT, once the migration is completed.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 MAINFRAME CAD PRIVILEGE TABLE SETTINGS
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100424
MIGRATION PLAN
 CADAM Drawing Database Migration
 System directory (symbol, font, format, stdnote) can also reside
anywhere, but you must define its location with cadprof. Default
is CCD_ROOT\Drawings\System directory.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Drawing database can reside on any disk drive that Windows can
access. No more (group,user) directory structure required. This
is similar to Helix’s OS File Format.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100425
MIGRATION PLAN
 Decide where the CADAM database will reside
 On Windows or UNIX.
 CADAM’s (group,user) database structure can be duplicated with
directories/subdirectories on Windows.
 Windows Security: directories and file access
permissions
 NTFS formatted disk or partition is required.
 Use the Administration Utilities to set file access permissions on
production release or shared directories, files, etc.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 FAT32 File Systems are supported, but NTFS is recommended.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100426
MIGRATION PLAN
 CADAM Drawing Database Migration to Windows
 From Mainframe CADAM
 The Data Transfer utility of either Professional CADAM or CATIA-CADAM Drafting on
UNIX is required to transfer the symbol and font tables.
Symbol and Font Tables:
 Use the original FT05F001 index file used to create the tables on the mainframe.
 If not available the index file can be created on the UNIX workstation.
 For font tables you should also locate the mainframe font spacing table FT08F001, but it
Plot Format tables (not a manual step anymore!):
 As of CCD V423PTF1 and CCD V5R4 SP1, plot format tables are now synchronized
automatically on on all supported platforms. Some configuration required.
 For Mainframe CADAM it is still a manual process if there is no TCP/IP connection to
the mainframe.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
is not required -- the default will work.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100427
MIGRATION PLAN
 CADAM Drawing Database Migration to Windows (con’t)
 From Helix
 Symbol and Font Tables:
 BULKXFER, included with the Helix Migration Package, automatically transfers all the
symbol and font tables from Helix (sys,symbol) to CCD.
 Plot Formats
 BULKXFER transfers all the format models in (sys,format) and appends the new
© 1997 – 2000 DASSAULT SYSTEMES
formats to the current CCD format table.
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100428
MIGRATION PLAN
 CADAM Drawing Database Migration (con’t)
 From PROFESSIONAL CADAM on UNIX (or IBM’s old RT)
 Run db_update to change the model naming convention from the C_ /C_/C_xxx to the
newer D_xxx
 Run mdlupd UNIX IUE utility to update and rename models to the new CCD convention:
to
xxx.cdd (note that is .cdd not .ccd)
» Optionally opens and files all models (required if migrating from RT-CADAM
and recommended for early versions of PRO CADAM pre-V3R5).
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
» Rename all models from D_xxx
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100429
MIGRATION PLAN
 CADAM Drawing Database Migration (con’t)
Special characters in the model name
 Since MF CADAM, PROFESSIONAL CADAM, CCD-UNIX and Helix
use their own data manager, special characters such as: * \ ?,
could be used in the model name. These characters cannot be
used in a Windows file name.
 Use the mapping tables under the CCD_ROOT\PROFILE\convert\tables directory to map
the special characters to a valid character on Windows:
UCS-2_NAME-8859.map
(maps to WIN)
(maps from WIN)
Note: ICF, MCXTRAN and Data Transfer use these tables (not PCNFS).
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
For English: NAME-8859_UCS-2.map
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100430
MIGRATION PLAN
SYMBOL TABLE NAMING CONVENTIONS
CCD or PRO CADAM
CCD - WIN ( 20 characters max)
FONT TABLES
DRAWINGS/system/font/D_128/D_fonts
\Drawings\system\font\128-fonts.cdd
DRAWINGS/system/font/D_128/FSpace
\Drawings\system\font\128-FSpace.bin
SYMBOL TABLES
\Drawings\system\symbol\001-symbols.cdd
FORMAT TABLES
DRAWINGS/system/format/D_8009a
\Drawings\system\format\8009a.cdd
STDNOTE TABLES
DRAWINGS/system/stdnote/D_cadam_std_mm
DASSAULT SYSTEMES Information for Users Forum
\Drawings\systems\stdnote\cadam_std_mm.cdd
© 1997 – 2000 DASSAULT SYSTEMES
DRAWINGS/system/symbol/D_001/D_symbols
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100431
MIGRATION PLAN
SPECIAL CHARACTERS: MF OR UNIX TO WINDOWS
 CCD uses the Unicode Standard character set
 User-defined special characters on UNIX (PRO CADAM or CCD)
and MF CADAM need to be recreated on Windows.
 Use CCD’s fontutil (located under CCD_ROOT\gphigs) to create the new characters.
 New characters must be defined in the Unicode User Define area E800-EFFF. This area
allows for 1,792 new characters to be defined.
 Professional CADAM versions prior to V3R5 did not support the
Unicode Standard, therefore in addition to the above steps you
need to:
 Modify the character mapping table corresponding to the language locale being used.
The mapping tables are located under the CCD_ROOT\profile\convert\tables directory.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Use the cadspec utility to add the new characters to the Special Character Window.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100432
MIGRATION PLAN
SPECIAL CHARACTERS: MF OR UNIX TO WINDOWS (con’t)
 Helix and MICRO CADAM
 A new mapping table has been added to support the Helix and
older MICRO CADAM special characters:
 Ccdraft\Profile\Convert\Tables\Helix-8859_ucs-2.map
© 1997 – 2000 DASSAULT SYSTEMES
 Check the Migration Package on www.cadam.com for any
updates to this table.
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100433
MIGRATION PLAN
REF-ENT IS AN EXCEPTION TO THE RULE
 Reference Entity models must reside in a directory\subdirectory, with a name that must match the name of the
group,user where the original reference entity model was
located on UNIX or MF.
In addition, these directories must reside under the
CCD_ROOT\Drawings directory defined in cadprof.
 The model eng-dwg-3 in eng,bob references the model ref3 located in eng,ref
 On Windows
 The model eng-dwg-3 can be anywhere, but the model ref3 must be located under the
CCD_ROOT\Drawings\eng\ref\ directory.
 Note: If a model is created on Windows, the reference entity must reside in the same
directory
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 For example, on MF or UNIX
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100434
ON-LINE DOCUMENTATION
 ON-LINE DOCUMENTATION
 On-line help is now in HTML format. A browser such as Internet
Explorer or Netscape is required.
© 1997 – 2000 DASSAULT SYSTEMES
 The full documentation, including the User Guides, can be
accessed and printed from Ccdraft\En_US\Help\doc.htm
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100435
ADMINISTRATOR TIPS
 Cleanup after Data Transfer
 Check for files under Ccdraft\datatran\temp directory
 If failures occur during the data transfer process, temporary files may be left behind
and some of these files can be very large. Delete them.
 Check Ccdraft\datatran\sysinfo\requests
 Delete old request files
 Cleanup after the External File translator
 Cleanup after Plotting
 Ccdraft\tmp, Ccdraft\plot\requests, Ccdraft\plot\status
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Check for files under Ccdraft\tmp and C:\tmp
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100436
ADMINISTRATOR TIPS
 CCDVER utility has been enhanced.
 All user modifiable installation parameters are now
kept in the CCD_ROOT\Profile directory.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Starting with CCD 421R2 and CCD V5, you can change the CCD
environment variables with CCD_ROOT\Bin\ccdver.exe. This will
allow you to configure multiple CCD environments on the same
system without conflicts. See next page for sample screen.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100437
© 1997 – 2000 DASSAULT SYSTEMES
ADMINISTRATOR TIPS
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100438
ADMINISTRATOR TIPS
 CCD Service Packs for V5 and PTFs for V4
 Made available as needed to resolve severe problems, but no
more than four between releases.
 Available only from www.cadam.com, under Software Downloads
 TRAINING
 Current MF or UNIX CADAM users may need help using CCD’s
new Windows user interface.
 Schedule training to immediately follow the installation.
 Take a Windows NT or Windows 2000 Administration class.
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 Since Helix and CCD are so similar, training may not be
necessary. The minor differences can be covered in a few hours.
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100439
IMPORTANT WEB SITES
New CADAM Web Site: http://www.cadam.com
with links to:
 CCD SOFTWARE, WHITE PAPERS, UPDATES
(Service Packs & PTFs) AND GENERAL
INFORMATION.
 IBM’s SITE:
 CCD SALES AND GENERAL INFORMATION:
 http://www.catia.ibm.com/prodinfo/ccdhome.html
DASSAULT SYSTEMES Information for Users Forum
© 1997 – 2000 DASSAULT SYSTEMES
 http://www.ibm.com/solutions/engineering/escatia.nsf/public/whitepapers
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100440
© 1997 – 2000 DASSAULT SYSTEMES
Questions?
DASSAULT SYSTEMES Information for Users Forum
Windows Installation Tips and Techniques for CCD & CATIA V5 2000100441
Download