IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES IEC 62368-1, 2 Ed. (2014-02) TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING R = Required to be at Lab IEC 62368-1 test equipment has been identified for use in the sub-grouped below: RA = Required for Amplifiers; in addition to RB, required for apparatus with audio amplifiers (audio power > 0,5 Watts) RB = Required Basic - test and measurement equipment required for all apparatus RC = Required for Cable distribution system; in addition to RB, required for apparatus with connection(s) to a cable distribution system RSH = Required for SHredder; in addition to RB, required for shredder RT = Required for Telecom; in addition to RB, required for apparatus with connection(s) to a telecommunication network RV = Required for CRT / Plasma/LCD or other Video equipment in addition to RB required for testing CRT Cathode ray Tubes/ picture tubes, plasma/LCD or other video apparatus S = May be Subcontracted SP = SPecialized testing facility W = May be Witnessed at MTL Clause Measurement/testing 62368-1 1Ed. 4.7 Equipment for direct insertion in to mains socket-outlets 4.8 Coin/button cell batteries 5.2.2.2 5.2.2.4 5.3.2. 5.4.1.10 Steady- state voltage and current limits Single pulse limits Accessibility to electrical energy sources and safeguards Thermoplastic parts on which conductive metallic parts are directly mounted 5.4.1.4, 9.2.5 Maximum operating 2014-04-06 Testing / measuring equipment / material needed Subcontracting Test equipment (see Fig. 11 of IEC 60065) RB 30 N ± 1N applied by rigid test finger (Figure V.2); test hook (Figure 20) Crush Test – 300 N ± 5N; flat surface measuring 100 mm by 250 mm; timer Amp- and voltmeter suitable for the current and waveform, frequency meter Measuring instruments in according IEC 60990: 1999 Figure 4 and 5 Oscilloscope Blunt probe of Figure V.3 RB RB RB Vicat test B 50 of ISO 306 Ball pressure test apparatus according to IEC 60695-10-2 Oven at least 125ºC Voltage supply Single phase voltage supply systems/variability/adequacy S RB IEC 62368-1, 2 Ed. (2014-02) RB RB RB IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62368-1 1Ed. Measurement/testing Testing / measuring equipment / material needed temperatures for materials, components and systems Temperature (rise) 5.4.5.2 Clearances, creepage distance, solid insulation 5.4.8 Antenna terminal insulation Thermal cycling test procedure Humidity conditioning 5.4.9 Electrical strength test 5.4.10 Safeguards against transient voltages from external circuits Separation between external circuits and earth Capacitor discharge 5.4.1.5.3 5.4.11 5.5.2.2 2014-04-06 Three phase voltage supply systems Temperature recorder (multi-channel) Thermocouples Winding resistance (normally > 1,0 2-wire, 4-wire <1,0 ). Voltmeters (ac/dc) High voltage meter (probe) Currents (ac/dc) Loads (resistive) Subcontracting Current Loading Oscilloscope Dial gauge or caliper Micrometer Pins etc. With different diameters Microscope Impulse test generator circuit 1 of Table D.1. Impulse test generator circuit 2 of Table D.1. impulse test generator circuit 3 of Table D.1 S RB RB RB RB RB RB RB RB RB RB RB RB RT S RC Test equipment for tracking index per IEC 60112 Mandrel (figure 25 to 28), metal foil, equipment suitable for electrical strength test loads Insulation resistance meter (500V > 4 MΩ), Impulse test generator circuit 1 of Table D.1 S S RC Voltage 5.4.2, 5.4.3, 5.4.4 COMMITTEE OF TESTING LABORATORIES S Full draught oven ( 2ºC) Cooling facility (0º±2 C) Chamber RH( 93 ± 3)%, 20...30 C Chamber RH (93 ± 3)%, (40 ± 2)C Test Instrument/equipment according to Figure 29 for electric strength Test equipment with relevant voltage and trip current Blunt probe figure V.3 RB RB RB Non-inductive Resistor 5000ΩAmpere meter RB Measuring instrument with input impedance 100M or more in parallel with an input RB IEC 62368-1, 2 Ed. (2014-02) RB IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62368-1 1Ed. Measurement/testing COMMITTEE OF TESTING LABORATORIES Testing / measuring equipment / material needed Subcontracting capacitance of 25pF or less Annex T 5.6.4.1 5.7 6.2.2 6.4.8.3.3 8.2 8.5.4.2 8.5.5.2. 8.6.2 8.6.4 8.6.5 8.7 8.8 Annex T Resistance of protective conductors and their terminations Determination of the overcurrent protective device and circuit (Annex R) Prospective touch voltage, touch current and protective conductor current Power source circuit classification Top openings and top openings properties Mechanical energy source classifications Equipment having an electromechanical device for destruction of media Force of 10 N ±1 N High current source with a voltage not exceeding 12 V, High pressure lamps Static stability for floor standing equipment Dark sticky mat, , magnified glass with a resolution of 0,1 mm Inclined plane 15° (Inclined plane 10 Force 250N/ Test tool 800Nwith a flat surface 12,5cm by 20cm Glass plate, 10° Inclined plane 15°, force 100N Glass slide test Horizontal force test Equipment mounted to a wall or ceiling Handle strength test method 2014-04-06 Source with at least 1500A short circuit RB RB S Networks in according IEC 60990:1999 figures 4 and 5; Amp-meter RB Watt meter, variable resistor load, stop watch RB Cheesecloth bleached cotton cloth 40g/m 2 RB Scale up to 25kg RB Test probe (jointed) of Annex V (figure V.1 and V.2) and wedge probe V.4 Force 45N and 90 N with wedge probe Several weights, timer Torque gauges 75mm width, several weights, scale, timer IEC 62368-1, 2 Ed. (2014-02) RB RSH RB RB RB RB RB RB RB RB RB IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause 62368-1 1Ed. 8.9 8.10 8.11 8.12 10 Measurement/testing Subcontracting Force 20N, stop watch RB Force up to 440 N with a circular plan surface 30mm, , stop watch, RB Mounting means for rack mounted equipment Telescoping or rod antennas (Annex T.11) Radiations Several weights, timer RB test tool for applying torque up to 0,6Nm, test tool for applying force 20N, stop watch RA Input test Annex B.3.2 Covering of ventilation openings Test conditions for equipment contain audit amplifiers Annex F.3.10.2 Annex F.3.10.3 Annex G.5.4.5.3 Testing / measuring equipment / material needed Wheels or casters attachment requirement Carts, stands and similar carriers Annex B.2.5 Annex E COMMITTEE OF TESTING LABORATORIES Laser (including laser diodes) Several special equipment for laser classification(IEC 60825-1) Light emitting diodes (LEDs) Several special equipment for LED classification(IEC 62471:2006) X-ray Radiation monitor, ionizing chamber type with an effective area of 1 000 mm² Effect of UV radiation on Test equipment according to ISO 178, 179, 180, 527 and materials (Annex C) 8256 and according ISO 4892 series. Human exposure to UV radiation Measuring equipment according to IEC 62471 (Annex C) Acoustics Special equipment for acoustic measurements (EN503321/-2) Amp-meter suitable for the current and waveform, power meter, voltmeter, Variable loads Signal generator in acc. IEC 60107-1:1997 piece of card with 200 g/m² density S S S S S S RB RB RV RB RA RA Durability Testing box Signal generator (sinus) 1kHz or alternative Band-pass filter for wide-band noise measurement, pink noise signal generator water/piece of cloth/ timer Durability Petroleum spirit (85% n-hexane), (CAS# 110-54-3) RB Alternative test method Cheesecloth (bleached cotton cloth 40g/m 2), Wrapping Tissue (12g/ m2 – 30g/m2) RB 2014-04-06 IEC 62368-1, 2 Ed. (2014-02) RB IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause Measurement/testing 62368-1 1Ed. G.5.4.6.3 G.9.3 S.3.1 S.3.2 Annex G.7 Mains supply cords Testing / measuring equipment / material needed Test equipment according IEC 60227 Appropriate weights Torque meter or equivalent resistor: 100 Ω +/- 5 Ω capacitor: 425 μF +/- 10µF inductance: 0,35 mH +/- 0,1mH; <1 Ω dc resistance Oven with a range of -30°C+/-2°C up to 70°C +/-2°C 50°C± 2°C for 10 min; followed by 10 min at 0°C± 2°C with a 5 min period of transition from one state to the other Annex G.9 IC current limiters Annex G.10 Test for resistor serving as Impulse test generator circuit 1 of Table D.1. safeguard Impulse test generator circuit 2 of Table D.1. impulse test generator circuit 3 of Table D.1 Test according to IEC 60068-2-78 Test method and Full draught oven (± 2ºC) compliance criteria Abrasion resistance test Scratch test device with steel pin Annex G.13.6.2 Annex G.13.6.2 Annex G.15 Annex H Annex J Annex M.6.2 Pressurized liquid filled components Hydrostatic pressure Tubing and fittings compatibility test Vibration test Criteria for telephone ringing signals Insulated winding wires for use without interleaved insulation Leakage current 2014-04-06 COMMITTEE OF TESTING LABORATORIES Hydrostatic pressure test device Tensile strength test device in acc to ISO 527 series Subcontracting S RB RB S RT S RC S S S S S Vibration generator (0,35mm/10Hz-55Hz-10Hz) IEC 60068-2-6 5 000Ω resistor S RT Test equipment according to IEC 60851-3,IEC 60851-5 and IEC 60851-6 S Insulation resistance meter S IEC 62368-1, 2 Ed. (2014-02) IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT Clause Measurement/testing 62368-1 1Ed. Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex P.2 Safeguards against entry of solid foreign objects Annex. P.4 Metallized coatings and adhesives securing parts Annex S Tests for resistance to heat and fire Annex T.2 - T.4 Annex T.5 Annex T.6 Annex T.7 AnnexT.8 Annex T.9 Annex U Annex V.1.2 Annex V.1.3 Annex V.1.4 Annex V.1.5 Steady force test Steady force test, 250 N Enclosure impact test Drop test Stress relief test Impact Test Mechanical strength of CRTs and protection against the effects of implosion Test method 1 – Surfaces and openings tested with jointed test probes Test method 2 – Openings tested with straight unjointed test probes Test method 3 – Plugs, jacks, connectors Test method 4 – Slot openings 2014-04-06 COMMITTEE OF TESTING LABORATORIES Testing / measuring equipment / material needed Equipment according to IEC 60896-21:2005 Sub cl. 6.4 Subcontracting S Suitable tool (or tools) to simulate a straight metal object, 1mm in diameter, length up to 13 mm Oven RB Needle flame test apparatus acc. to IEC 60695-11-5:2004 Distillate fuel oil as described in Annex S.3.2 500W flame test apparatus in acc. to IEC 60695-11-20:1999 Cheesecloth (bleached cotton cloth 40g/m 2), Wrapping Tissue (12g/ m2 – 30g/m2) 10N ± 1N Test finger (figure V1 or V2 unjointed , 30N 3N) Test tool 100N 10N with a circular plan surface 30mm Stop watch Test tool 250N 10N with a circular plan surface 30mm. 50mm/500g 25g steel ball Hard wood 13mm on 18mm ± 2mm plywood, two layers. ruler up to 1000 mm ± 10mm Measuring equipment according to IEC 60695-10-3 or Oven 70K over normal temp. steel ball 50mm, approx 500g., Fragmentation test Centre punch and a square of 50 mm side Test equipment acc.IEC 61965 Scale, diamond stylus, cooling liquid, timer RB S RB RB RB Figure V.1 – Jointed test probe for equipment likely to be accessible to children Figure V.2 – Jointed test probe for equipment not likely to be accessible to children RB Figure V.1: straight unjointed version of the respective test probe applied with a force of 30 N. RB Figure V.3 – Blunt probe RB Figure V.4 – Wedge probe IEC 62368-1, 2 Ed. (2014-02) S RB RB RB RB RB S RSH IEC SYSTEM FOR CONFIRMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES Clause Measurement/testing Testing / measuring equipment / material needed 62368-1 1Ed. Annex V.1.6 Test method 5 – Terminals Force 1 N ± 0,1N intended to be used by an Terminal probe IEC 61032:1997 figure 4 ordinary person Subcontracting RB Note: The presence of equipment alone does not indicate a satisfactory situation. Assessors must evaluate the equipment design, calibration, uncertainty and documentation to ensure compliance with the directions of the standard. The requirements of ISO/IEC 17025 regarding validation are applicable, as the tests of this standard are not standardised tests. 2014-04-06 IEC 62368-1, 2 Ed. (2014-02)