The apparatus, when fully equipped and loaded, shall be capable of

advertisement
RAGE Pumper Demo #4000
Wildland Type III
PREREQUISITE BIDDING REQUIREMENTS
Any manufacturer submitting a proposal or bid, to these specifications; shall meet the following
conditions.

The manufacturer of the apparatus herein specified; shall be wholly owned (100%) and managed by
a Company, Corporation, and/or Parent Company that is wholly based, and permanently resides in
the United States of America.

The Company, Corporation, and/or Parent Company, and all assets belonging to such; shall be
wholly owned and managed (100%) by the entities specified above.

Any proposal, bid, or response to these specifications by any foreign based, owned, or managed (in
part or in whole) Company, Corporation, and/or Parent Company; shall be cause for immediate
rejection.

Any proposal, bid, or response to these specifications by any Company, Corporation, and/or Parent
Company, that is owned, operated, managed, or held in contract; in part or wholly by a partnership or
other agreement; shall be cause for immediate rejection.
Exceptions to these conditions will not be allowed under any circumstances.
NFPA 1906-2006
The National Fire Protection Association “Standard for Wildland Fire Apparatus”, 2006 edition, is hereby
adopted and made a part of these specifications, the same as if it were written out in full detail, with the
exception of the section dealing with "Equipment Recommended for Various Types of Apparatus".
Bidders shall provide the equipment requested herein and the buyer shall supply the rest before the
apparatus is put into service. It is the intent of the purchaser to purchase an apparatus that meets 100%
of the minimum standards defined and outlined in NFPA 1906-2006 edition. There are to be no
exceptions to this requirement.
STATEMENT OF EXCEPTIONS
The proposed apparatus as described in this specification document and all related material with the bid
package shall meet or exceed all applicable sections for the category of apparatus as defined by NFPA
1901 newest edition, unless specifically noted within this specification or other official documents
associated with this bid.
Should any area, section or portion of the apparatus not meet the intent and applicable requirements, a
clearly defined listing or explanation of what and why compliance was not achieved shall be provided to
the purchaser at the time of delivery.
VEHICLE STABILITY
The apparatus shall comply with the requirements of NFPA 1901, newest edition, as it applies to vehicle
stability. The particular apparatus as described in the specification provided within the bid package shall
be classified into one of the following categories:

The apparatus shall go through actual tilt table testing. This shall be determined by the
Revised February 28, 2011
Page 1 of 64
RAGE Pumper Demo #4000
Wildland Type III
Apparatus manufacturer
 The apparatus shall be equipped with rollover stability control systems as defined in section
4.13.1.2 of NFPA 1901, newest edition
 The apparatus shall be deemed a similar apparatus and meeting the intent of section
4.13.1.1.2 of NFPA 1901, newest edition
INTENT OF SPECIFICATIONS
It is the intent of these specifications to cover the furnishing and delivery to the purchaser of a complete
apparatus equipped as herein specified. With a view to obtaining the best results and the most
acceptable apparatus for service in the fire department, these specifications cover the general
requirements as to the type of construction, together with certain details as to finish, equipment, and
appliances with which the successful bidder must conform. Minor details of construction and materials
where not otherwise specified are left to the discretion of the contractor, who shall be solely responsible
for the design and construction of all features.
Bids shall only be considered from companies that have an established reputation in the field of fire
apparatus construction and have been in business for a minimum of 50 years.
Each bidder shall furnish satisfactory evidence of his ability to construct the apparatus specified, and shall
state the location of the factory where the apparatus is to be built. The bidder shall also show that they
are in a position to render prompt service and furnish replacement parts for said apparatus.
CONTRACTOR'S SPECIFICATIONS
Each bid shall be accompanied by a set of "Contractor's Specifications" consisting of a detailed
description of the apparatus and equipment proposed and to which the apparatus furnished under
contract must conform.
These specifications shall indicate size, type, model, and make of all component parts and equipment.
TIMELY PROPOSALS
It is the bidder's responsibility to see that their proposals arrive on time. Late proposals, facsimiles, emails, telegram, or telephone bids shall not be considered.
DRAWINGS
All bid drawings will be stamped PRELIMINARY DRAFT.

A total of six (6) “C” size drawings and one (1) 11” x 17” drawing will be supplied

All drawings will be drawn and printed in a 3/8 to 1 scale

Compartment door opening dimensions will be shown on table on the drawing which will refer to each
compartment number, such as L1, R1, T1

Drawings will be five (5) view. (left, right, front, rear, top) with the exception of chassis that are not
always available as AutoCAD drawings

Rear plumbing, such as 2-1/2” discharges, rear steamers, and direct tank fills, will be shown
Revised February 28, 2011
Page 2 of 64
RAGE Pumper Demo #4000
Wildland Type III

Ladders will be labeled with a letter designation referring to the table for an explanation of the ladder
type

OAL (overall length) in feet & inches Estimated length will be rounded up to the nearest inch

OAH (overall height) in feet & inches
Estimated height will be rounded up to the nearest inch

Body dimensions shown - pump house width & front of the body to centerline of the rear axle

Wheelbase in inches

Estimated in-service weight

Turning clearance radius

Front and rear overhang in inches

No pump panel or instrument panel controls, discharges or inlets. To be blank and labeled “Pump
Panel”

Water tank outline

Foam tank(s) fill towers

Exterior mounted hard suction hose

Warning lights

D.O.T. lights

Generator outline

No front bumper layout

Rollup doors will be shown in open position. Lap doors will be shown in the closed position

Compartment depth break over measurement. The measurement where the compartment switches
from full depth to shallow depth

Angle of approach and departure

Top view of chassis
Text Block Items







Chassis model
Water tank capacity
Foam tank capacity
Hose bed capacity in cubic feet
Total compartment cubic feet
Drawing box is to read “BID” and utilize the bid number
Drawings will be printed on white paper with black ink, blue line drawings will not be acceptable.
Revised February 28, 2011
Page 3 of 64
RAGE Pumper Demo #4000
Wildland Type III
PURCHASER'S OBLIGATIONS
The purchaser reserves the right to accept or reject any or all bids on such basis as the purchaser deems
to be in its best interest. All bidders shall be advised that the purchaser is not bound in any manner to
automatically accept the lowest bid. The purchaser shall only be obligated to purchase the lowest bid that
meets these detailed specifications as closely as possible.
SAFETY REQUIREMENTS
It is required that the bidder shall meet all State and Federal safety standards and laws that are in effect
on the date of the bid for the item(s) that are being specified and the particular use for which they are
meant.
ACQUAINTANCE WITH SPECIFICATIONS
It is the responsibility of the bidder to review all of the bidding requirements. Failure of a bidder to be
acquainted with this information shall not relieve them from any obligations of the bid requirements.
QUALITY AND WORKMANSHIP
The design of the apparatus shall embody the latest approved automotive engineering practices.
Experimental designs and methods shall not be acceptable.
The workmanship shall be of the highest quality in its respective field. Special consideration shall be
given to the following points: accessibility of the various units that require periodic maintenance, ease of
operation (including both pumping and driving), and symmetrical proportions.
Construction shall be rugged and ample safety factors shall be provided to carry loads as specified.
GENERAL CONSTRUCTION
The complete apparatus, assemblies, subassemblies, component parts, and so on, shall be designed and
constructed with due consideration to the nature and distribution of the load to be sustained and to the
general character of the service to which the apparatus is to be subjected when placed in service.
All parts of the apparatus shall be strong enough to withstand the general service under full load. The
apparatus shall be so designed that the various parts are readily accessible for lubrication, inspection,
adjustment and repair.
The apparatus shall be designed and constructed, and the equipment so mounted, with due consideration
to distribution of the load between the front and rear axles, and side to side loading that all specified
equipment, including a full compliment of specified ground ladders, full water tank, loose equipment, and
firefighters; shall be carried without overloading or injuring the apparatus as per requirements defined in
NFPA. 1906.
The main apparatus body structure shall have an approximate width of 98" in order to maximize the
enclosed compartment space of the apparatus. The 98" wide measurement represents the main body
structure measured from the bottom, outermost rear corners of the apparatus body structure.
Components affixed or fastened to the apparatus will increase the body width proportionately.
Revised February 28, 2011
Page 4 of 64
RAGE Pumper Demo #4000
Wildland Type III
LIABILITY
The bidder, if their bid is accepted, shall defend any and all suits and assume all liability for the use of any
patented process, device or article forming a part of the apparatus or any appliance furnished under the
contract.
WARRANTY
A copy of the warranties for the pump, body, paint, and water tank shall be furnished with each bidder's
proposal.
BID FORMS / SPECIFICATIONS
All bid forms shall be submitted on the attached bid form. The bid form and / or these specifications shall
be filled out by checking either the "YES" or "NO" column for each and every section / paragraph. Failure
to use this form and / or these specifications shall be cause for immediate rejection of any bid.
EXCEPTION TO SPECIFICATIONS
The following chassis, pump, and body specifications shall be strictly adhered to. Exceptions shall be
allowed if they are equal to or superior to that specified (as judged by the customer), and provided they
are listed and fully explained on a separate page entitled "EXCEPTIONS TO SPECIFICATIONS".
Exception lists shall refer to the specification page number. Each check in the "NO" column shall be
listed and fully explained. Where no check is made in a particular paragraph either "YES" or "NO", it shall
be assumed the bidder is taking exception to that paragraph. If a paragraph contains an empty column,
where the bidder neglected to check the proper “YES” or “NO” column, it is assumed the bidder is not
conforming to the requirements of this paragraph. If no explanation is given in the “EXCEPTIONS TO
SPECIFICATIONS” document the bid is subject to immediate rejection.
PROPOSALS TAKING TOTAL EXCEPTION TO THESE SPECIFICATIONS WILL BE IMMEDIATELY
REJECTED.
The buyer is aware that all bidders shall have to take some exceptions therefore; BIDDERS THAT TAKE
NO EXCEPTIONS shall BE REQUIRED TO MEET EVERY PARAGRAPH TO THE FULLEST EXTENT
SHOULD THEIR BID BE ACCEPTED. It is the intent of the purchaser to receive bids that do not require
telephone calls or other communications to ascertain what a bidder is intending to supply.
Upon delivery, the apparatus shall be inspected against THESE specifications and not those supplied by
the bidder with their proposal. Deviations shall not be acceptable unless they were noted as exceptions
at the time of bid and the apparatus shall be rejected until said deviations are corrected to the satisfaction
of the buyer.
Decisions regarding equal to or better than, shall be the sole responsibility of the recipient of the bids
rather than those companies submitting bids. All deviations, regardless of significance must be explained
in the “Exceptions to Specifications” section of the bid.
When exceptions are not taken but inconsistencies are noted in the submitted detailed specifications, the
bid may be subject to rejection.
Revised February 28, 2011
Page 5 of 64
RAGE Pumper Demo #4000
Wildland Type III
ROADABILITY
The apparatus, when fully equipped and loaded, shall be capable of the following performance while on
dry paved roads that are in good condition:

From a standing start, the apparatus shall be able to attain a speed of 35 mph (55 kmph) within
25 seconds on a level road.

The apparatus shall be able to attain a minimum top speed of 50 mph (80 kmph) on a level road.

The apparatus shall be able to maintain a speed of at least 20 mph (30 kmph) on any grade up to
and including 6 percent.
FAILURE TO MEET TESTS
In the event the apparatus fails to meet the test requirements of these specifications on the first trials,
second trials may be made at the option of the bidder within 30 days of the date of the first trials.
Such trials shall be final and conclusive and failure to comply with these requirements shall be cause for
rejection. Failure to comply with changes as required to conform to any clause of the specifications within
30 days after notice is given to the bidder of such changes, shall be cause for rejection of the apparatus.
Permission to keep or store the apparatus in any building owned or occupied by the Department during
the specified period, with the permission of the bidder, shall not constitute acceptance. No Exceptions
PROPOSAL SEQUENCE
Bid specifications shall be submitted in the same sequence as these specifications for ease of checking
compliance. There shall be no exceptions allowed to this requirement. The apparatus committee intends
to be thorough during the evaluation of bids process. In order to maximize efficiency and minimize the
time it takes to thoroughly evaluate all received bids this requirement must be strictly adhered to.
AWARD OF CONTRACT
All bids submitted shall be good for a minimum of 30 days during which time bid securities submitted with
the proposals shall be held by the purchaser. Criteria for the award shall include, but not be limited to,
the following:











Apparatus Performance And Safety Levels / Considerations
Completeness of proposal
Accuracy of accompanying data
Past performance of bidder
Compliance with the detailed specifications
Compliance with purchasers request(s) for personnel qualifications or certifications
Exceptions and clarifications
Financial stability of bidder
Local representation of the manufacturer
Serviceability of the proposed apparatus
Service capabilities of the bidder's local representative
Revised February 28, 2011
Page 6 of 64
RAGE Pumper Demo #4000
Wildland Type III


Compliance with NFPA Pamphlet 1906 (newest edition)
Any other factor the purchaser deems relevant
After the evaluation and award process is complete, all bidders shall be notified of the results and
securities shall be returned.
CONSTRUCTION DOCUMENTATION
The contractor shall supply, at the time of delivery, at least one copy of the following documents:
1.
The manufacturers record of apparatus construction details, including the following information:
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
q.
r.
s.
Owners name and address
Apparatus manufacturer, model, and serial number
Chassis make, model, and serial number
GAWR of front and rear axles
Front tire size and total rated capacity in pounds (kg)
Rear tire size and total rated capacity in pounds (kg)
Chassis weight distribution in pounds with water and manufacturer mounted equipment (front
and rear)
Engine make, model, serial number, rated horsepower and related speed, and governed
speed
Type of fuel and fuel tank capacity
Electrical system voltage and alternator output in amps
Battery make, model, and capacity in cold cranking amps (CCA)
Chassis transmission make, model, and serial number; and if so equipped, chassis
transmission PTO(s) make, model, and gear ratio
Pump make, model, rated capacity in gallons per minute (liters per minute where applicable),
and serial number
Pump transmission make, model, serial number, and gear ratio
Auxiliary pump make, model, rated capacity in gallons per minute (liters per minute where
applicable), and serial number
Water tank certified capacity in gallons or liters
Aerial device type, rated vertical height in feet (meters), rated horizontal reach in feet (meters),
and rated capacity in pounds (kilograms)
Paint manufacturer and paint number(s)
Company name and signature of responsible company representative
2. Certification of slip resistance of all stepping, standing, and walking surfaces
3. If the apparatus has a fire pump, a copy of the following shall be provided: pump manufacturers
certification of suction capability, apparatus manufacturer’s approval for stationary pumping
applications, engine manufacturers certified brake horsepower curve showing the maximum
governed speed, pump manufacturer’s certification of the hydrostatic test, and the certification of
inspection and test for the fire pump
4. If the apparatus has an aerial device, the certification of inspection and test for the aerial device,
and all the technical information required for inspections to comply with NFPA 1914, Standard for
Testing Fire Department Aerial Devices
5. If the apparatus has a fixed line voltage power source, the certification of the test for the fixed
Revised February 28, 2011
Page 7 of 64
RAGE Pumper Demo #4000
Wildland Type III
power source
6. If the apparatus is equipped with an air system, test results of the air quality, the SCBA fill station,
and the air system installation
7. Weight documents from a certified scale showing actual loading on the front axle, rear axle(s),
and overall fire apparatus (with the water tank full but without personnel, equipment, and hose)
8. Written load analysis and results of the electrical system performance tests
9. When the apparatus is equipped with a water tank, the certification of water tank capacity
OPERATION AND SERVICE DOCUMENTATION
The contractor shall supply, at time of delivery, at least two sets of complete operation and service
documentation covering the completed apparatus as delivered and accepted.
The documentation shall address at least the inspection, service, and operations of the fire apparatus and
all major components thereof.
The contractor shall also provide documentation of the following items for the entire apparatus and each
major operating system or major component of the apparatus:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
Manufacturers name and address
Country of manufacture
Source of service and technical information
Parts and replacement information
Descriptions, specifications, and ratings of the chassis, pump, and aerial device
Wiring diagrams for low voltage and line voltage systems to include the following
information: representations of circuit logic for all electrical components and wiring, circuit
identification, connector pin identification, zone location of electrical components, safety
interlocks, alternator-battery power distribution circuits, and input/output assignment sheets
or equivalent circuit logic implemented in multiplexing systems
Lubrication charts
Operating instructions for the chassis, any major components such as a pump or aerial
device, and any auxiliary systems
Precautions related to multiple configurations of aerial devices, if applicable
Instructions regarding the frequency and procedure for recommended maintenance
Overall apparatus operating instructions
Safety considerations
Limitations of use
Inspection procedures
Recommended service procedures
Troubleshooting guide
Apparatus body, chassis, and other component manufacturers warranties
Special data required by this standard
Copies of required manufacturer test data or reports, manufacturer certifications, and
independent third-party
certifications of test results
20. A material safety data sheet (MSDS) for any fluid that is specified for use on the apparatus
Revised February 28, 2011
Page 8 of 64
RAGE Pumper Demo #4000
Wildland Type III
The contractor shall deliver with the apparatus all manufacturers operations and service documents
supplied with components and equipment that are installed or supplied by the contractor.
NFPA REQUIRED MANUALS
The construction, operation, and service documentation shall be provided on a CD-ROM. These manuals
shall be written in a "step by step" format for ease of reference. There shall be two (2) copies of the CD
provided with the apparatus as standard.
BODY STRUCTURAL INTEGRITY TEN (10) YEAR WARRANTY
The body shall be free of structural or design failure or workmanship for a period of ten (10) years or
100,000 miles starting thirty (30) days after the original invoice date.
PAINT LIMITED WARRANTY
The apparatus body and pump house shall be free of blistering, peeling and any other adhesion defect
caused by defective manufacturing methods or paint material selection for exterior surfaces for a period
of three (3) years starting thirty (30) days after the original invoice date.
Paint on the undercarriage, body interior (line-x coating included) or aerial structure related paint, if
applicable, is covered only under the Smeal Standard One Year Limited Warranty.
CORROSION LIMITED WARRANTY
The body exterior paint shall be warranted against corrosion perforation for a period of ten (10) years
starting thirty (30) days after the original invoice date.
STAINLESS STEEL TEN (10) YEAR LIMITED PLUMBING WARRANTY
The stainless steel plumbing shall be free from corrosion perforation for a period of ten (10) years starting
thirty (30) days after the original invoice date.
BASIC NINETY (90) DAY LIMITED WARRANTY
The apparatus shall be free of defects in material and workmanship for a period of ninety (90) days
starting thirty (30) days after the original invoice date.
STANDARD ONE (1) YEAR WARRANTY
The apparatus shall be free of defects in material and workmanship for a period of one (1) year starting
thirty (30) days after the original invoice date.
Revised February 28, 2011
Page 9 of 64
RAGE Pumper Demo #4000
Wildland Type III
OVERALL HEIGHT
The overall height of the vehicle shall be approximately 121" ( 10' 1" ) from the ground. This
measurement shall be taken with the tires properly inflated with the apparatus in the unloaded condition.
The actual measurement shall be taken at the highest point of the apparatus.
VEHICLE TOP SPEED
The vehicle’s top speed shall be 68 MPH.
OVERALL LENGTH
The overall length of the vehicle shall be approximately 314" ( 26' 2" ).
MISCELLANEOUS EQUIPMENT, NFPA 1906
Miscellaneous equipment, as defined in the newest edition of NFPA 1906-2006, sections 5.1.2 shall be
the responsibility of the purchaser. The apparatus shall be designed and manufactured in such a manner
as to provide ample enclosed space for which to store such equipment.
FIRE PUMP MOUNTING
The fire pump shall be mounted within a separate body module that is directly connected to the apparatus
body.
The pump shall be frame mounted; therefore minimizing the likelihood of the pump casing cracking
should the apparatus be involved in a collision.
The pump module shall be mounted to the frame and shall be reinforced appropriately in order to carry
the expected load for the life of the apparatus.
PTO MOUNTED FIRE PUMP
The fire pump shall be a Hale model TBP 750 PTO mounted unit, rated at 750 U.S. gallons per minute.
The pump shall be utilized for stationary pumping only.
TWO STAGE FIRE PUMP
The pump shall be a two stage centrifugal fire pump, designed specifically for the fire service.
The entire pump shall be assembled and tested at the pump manufacturer's factory.
The pump shall be driven by a driveline from the truck transmission. The engine shall provide sufficient
horsepower and RPM to enable the pump to meet and exceed its rated performance.
Revised February 28, 2011
Page 10 of 64
RAGE Pumper Demo #4000
Wildland Type III
PUMP CERTIFICATION
The fire pump shall be tested and certified by the apparatus manufacturer. Tests shall be conducted so
that the pump performs as listed below:




100% of rated capacity at 150 pounds net pressure
70% of rated capacity at 200 pounds net pressure
50% of rated capacity at 250 pounds net pressure
100% of rated capacity at 165 pounds net pressure
The entire pump, both suction and discharge passages, shall be hydrostatically tested to a pressure of
600 PSI. The pump shall be fully tested at the pump manufacturer’s factory to the performance spots as
outlined by the latest NFPA pamphlet. The pump shall be free from objectionable pulsation and vibration.
PUMP BODY
The pump body and related parts shall be of fine grain alloy cast iron, with a minimum tensile strength of
30,000 PSI. All moving parts in contact with water shall be of high quality bronze or stainless steel.
Pumps utilizing castings made of lower tensile strength cast iron are not acceptable.
The pump body shall be split, on a single plane in two sections for easy removal of the entire impeller
assembly, including wear rings and bearings from beneath the pump, without disturbing piping or the
mounting of the pump.
IMPELLER
The pump shall have two (2) impellers and be of a series-parallel, two-stage design. The pump shall be
equipped with an all bronze waterway transfer valve, capable of switching from one pumping mode to the
other with a air operated transfer valve. The transfer valve shall be equipped with a positive mechanical
indicator to register the position of the transfer valve at all times. A manual override shall also be
provided.
The pump shaft shall be rigidly supported by three bearings for minimum deflection. One high lead
bronze sleeve bearing shall be located immediately adjacent to the impeller. The sleeve bearing shall
be lubricated by a force-fed, automatic oil lubricated design, pressure balanced to exclude foreign
material. The remaining bearings shall be heavy-duty, deep groove ball bearings in the gearbox and they
shall be splash lubricated.
MECHANICAL SEAL
The pump shall be equipped with a mechanical seal. Only one (1) shall be required and it shall be located
on the suction (inboard) side of the pump. The mechanical seal shall be two (2) inches in diameter and
shall be spring loaded, maintenance free and self-adjusting. Mechanical seal construction shall consist of
a carbon sealing ring, stainless steel coil spring, Viton® rubber cup, and a carbide seat with Teflon®
backup seal.
PUMP GEARBOX
The gearbox shall be assembled and tested at the pump manufacturer factory.
Revised February 28, 2011
Page 11 of 64
RAGE Pumper Demo #4000
Wildland Type III
The gearbox shall be designed of ample capacity for lubrication reserve and to maintain the proper
operating temperature
The gearbox input shafts shall be of heat-treated chrome nickel steel and offset to align with a side
mounted truck transmission PTO.
All pump drive gears shall be of highest quality electric furnace chrome nickel steel. Bores shall be
ground to size and teeth integrated, shaved, hardened and ground to give an extremely accurate gear for
long life, smooth quiet running, and higher load carrying capability.
The pump ratio shall be selected by the apparatus manufacturer to give maximum performance with the
engine and transmission selected.
Oil shall be supplied with the pump gearbox.
HOT SHIFT PTO CONNECTION
The pump shall be connected to the chassis transmission through a "Hot Shift", electrically engaged
power-take-off system. The control to engage and disengage the power-take-off system shall be installed
in the chassis cab.
HALE ANODES
There shall be one (1) Hale alloy anodes provided with the fire pump. The anodes shall aid in preventing
galvanic corrosion within the water pump. The anodes shall be installed in the suction manifold of the
pump and shall easily replaceable.
HALE ANODES
There shall be one (1) Hale alloy anodes provided with the fire pump. The anodes shall aid in preventing
galvanic corrosion within the water pump. The anodes shall be installed in the discharge manifold of the
pump and shall easily replaceable.
HALE ANODES
There shall be one (1) Hale alloy anodes provided with the aux fire pump. The anodes shall aid in
preventing galvanic corrosion within the aux water pump. The anodes shall be installed in the discharge
manifold of the aux pump and shall easily replaceable.
THERMAL RELIEF VALVE W/INDICATOR
There shall be a thermal relief valve, model TRV-L120 installed on the pump. The relief valve shall
automatically relieve water from the pump when the temperature of the pump water exceeds 120 degree
Fahrenheit. The valve shall automatically reset after activation.
A light installed on the pump operator's panel shall indicate when the valve has been activated so the
pump operator may take corrective action. A "push to test" button shall be installed beneath the indicator
Revised February 28, 2011
Page 12 of 64
RAGE Pumper Demo #4000
Wildland Type III
lamp to allow the pump operator to test the lamp.
PUMP SHIFT INDICATING LIGHTS
There shall be two (2) green pump system shift indicator lights in the chassis cab. The first light shall
become energized when the pump has completed its shift into pump gear and shall be labeled "Pump
Engaged". The second light shall become energized when the chassis parking brake has been set, this
light shall be labeled "OK to Pump".
There shall be one (1) green pump system shift indicator light located on the operator's panel. This light
shall only become engaged when the chassis parking brake has been set, and when the pump has been
completely shifted into gear. The light shall be located adjacent to the throttle control and shall be labeled
"Warning: Do Not Open Throttle Unless Light Is On".
TRIDENT AIR OPERATED PRIMER
The priming pump shall be a Trident Emergency Products three barrel model 31.001.11 compressed air
powered, high efficiency, multi-stage, venturi based AirPrime™ System. All wetted metallic parts of the
priming system are to be of brass and stainless steel construction. A single panel mounted control shall
activate the priming pump and open the priming valve to the pump. The priming system shall have a five
year warranty.
ADDITIONAL PRIMER CONTROL
Additional primer control valves shall be furnished to prime the auxiliary pump. The RPV (remote priming
valve) shall activate using the same air that powers the AirPrime™ system when the coinciding panel
valve is depressed.
Location for the additional primer valves: One (1) located at the auxiliary pump control on the left pump
panel, One (1) located inside the chassis cab on the auxiliary pump control panel located on the center
console.
CLASS 1 "TOTAL PRESSURE GOVERNOR" GOVERNOR/CONTROLLER
The apparatus shall be equipped with a Class 1 “Total Pressure Governor” (TPG) model 117690, that is
connected to the Electronic Control Module (ECM) mounted on the engine. The “TPG” shall operate as a
pressure sensor (regulating) governor (PSG) utilizing the engines J1939 data for optimal resolution and
response.
Programmable presets for RPM and pressure settings shall be easily configurable using the TPGs
straightforward menu structure.
The “TPG” shall also include indication of engine RPM, system voltage, engine oil pressure and engine
temperature with audible alarm output for all. The “TPG” uses the J1939 data bus for engine information
requiring no additional sensors to be installed.
CLASS 1 SUN SHIELD
Revised February 28, 2011
Page 13 of 64
RAGE Pumper Demo #4000
Wildland Type III
There shall be a sun shield installed over the Total Pressure Governor.
INTAKE RELIEF VALVE
There shall be an Elkhart 40-41 intake relief valve installed on the suction side of the pump. The valve
shall be preset at 225 PSI. It shall be adjustable from 75 to 250 PSI and shall be designed to prevent
vibration from altering the setting. The relief outlet shall be directed below the pump with the discharge
terminating in a 2-1/2" male NST connection. The discharge shall be away from the pump operator and
labeled "Do Not Cap".
PUMP DRAIN VALVE
A ¼ turn drain valve assembly shall be supplied. This drain shall provide the capability to drain the entire
pump by turning a single control.
1/2" PUMP COOLER LINE
There shall be a 1/2" line installed from the discharge side of the pump to the water tank. The line shall
be used to cool the pump during long periods of pumping when water is not being discharged. The pump
cooler shall be controlled with a quarter-turn ball valve on operator’s panel, and shall be clearly labeled
"Pump Cooler".
PUMP COOLER CHECK VALVE
There shall be a check valve installed in the pump cooler line to prevent tank water from back flowing into
the pump when it is not in use.
PUMP MANUAL
Two (2) Pump Operation & Maintenance manuals in CD format shall be supplied at the time of delivery.
FIVE YEAR PUMP WARRANTY
The fire pump shall be warranted by Hale for a period of five (5) years from the date the product is first
placed into service or five and one-half (5-1/2) years from the shipment date by Hale, whichever period
shall be first to expire.
This warranty covers parts and labor for the first two (2) years. Warranty for the remaining three (3) years
shall cover parts only.
TANK TO PUMP CHECK VALVE
There shall be a check valve between the pump suction and the booster tank valve. The check valve
shall eliminate back flow into the water tank when the pump is connected to a pressurized source.
Revised February 28, 2011
Page 14 of 64
RAGE Pumper Demo #4000
Wildland Type III
TANK TO PUMP VALVE
There shall be one (1) 3" air operated full flow ball valve connected with a flexible hose from the tank to
the pump. The tank to pump valve shall be controlled from the pump operator's panel.
TANK FILL VALVE
There shall be one (1) Akron 2" full-flow tank fill valve plumbed with 2" plumbing from the pump to the
tank. Installation shall be completed with 2" Class 1 rubber hose and stainless steel hose couplings. The
tank fill valve shall be controlled from the operator's control panel.
PAINT PUMP – OEM STANDARD COLOR
The pump body shall be painted by the pump manufacturer.
AUXILIARY DIESEL PUMP
There shall be a Hale model HPX100-BD26 diesel engine auxiliary pump provided above the pump
compartment. The pump shall be plumbed in common with the foam manifold for pump and roll
applications. The pump shall have a minimum rated capacity of 110 GPM @ 200 psi.
PUMP INTAKE
The pump shall have a 3" female NPT intake that is plumbed directly into the tank.
PUMP DISCHARGE
The pump shall have a 2" female NPT discharge that is plumbed directly into the foam manifold of main
pump. There shall be a check valve provided in this line to keep the main pump from pressurizing the
auxiliary pump.
PUMP CONSTRUCTION
The pump volute body and head shall be constructed of cast iron with smooth waterways for maximum
performance.
IMPELLER
The impeller shall be a high strength corrosion resistant bronze, fully enclosed, double hubbed to balance
hydraulic thrust, and mechanically balanced to eliminate vibration.
Revised February 28, 2011
Page 15 of 64
RAGE Pumper Demo #4000
Wildland Type III
WEAR RINGS
The pump wear rings shall be long wearing bronze. Easy to replace when required for restoring original
pump efficiency.
DRIVE SHAFT
The pump drive shaft shall be high strength stainless steel.
SHAFT SEAL
The pump shaft seal shall be a spring loaded mechanical type.
GEAR CASE
The pump gear case shall include a speed increaser utilizing high strength aluminum alloy case, helical
cut, hardened steel gears and antifriction bearings throughout.
DIESEL ENGINE
The diesel engine shall be a Briggs & Stratton DM950D. The engine shall be capable of delivering a
maximum output of 26.5 hp @ 3600 RPM.
LUBRICATION
A pressure feed oil system with a spin on filter, shall lubricate the pump engine.
STARTER
The engine shall be supplied with a 12 volt electric starter.
ALTERNATOR
There shall be a 12-14 volt, 40 amp alternator provided on the engine.
CONTROLS ON THE PUMP PANEL
There shall be one (1) control panel provided with the auxiliary pump. The control panel shall be
mounted on the pump panel.
Controls located on the pump panel shall include:



Vernier Throttle
Tachometer
On/Off/Start switch
Revised February 28, 2011
Page 16 of 64
RAGE Pumper Demo #4000
Wildland Type III





Amber - Aux Pump Engine Running Light
Red - Water temp overheat warning Light
Red – Low Engine Oil Pressure Warning Light
Aux Pump Primer Button
2 ½” Class 1 0-400 Psi water pressure gauge
REMOTE CONTROLS IN THE CAB
There shall be an additional control console provided in the cab. The control panel shall be located in the
center console.
Controls located on the in the chassis cab shall include:







Momentary switch for Throttle acceleration and deceleration
On/Off/Start switch
Amber - Aux Pump Engine Running Light
Red - Water temp overheat warning Light
Red – Low Engine Oil Pressure Warning Light
Aux Pump Primer Button
2 ½” Class 1 0-400 Psi water pressure gauge
AUXILIARY PUMP COVER
A treadbrite cover shall be installed over the auxiliary pump. The cover shall be designed in such a
manner as to allow for easy access to the auxiliary pump when performing routine maintenance. The
cover shall also be designed in compliance with the engine manufacturer's air flow requirements.
DIRECT TANK FILL VALVE
There shall be one (1) 2-1/2" direct tank fill on the rear of the apparatus. The tank fill shall be plumbed
with a 2-1/2" Akron valve and 2-1/2" plumbing. The direct tank fill valve shall be controlled utilizing a
chrome plated handle located directly on the valve. The handle shall have a round ball at the end and
shall be easily actuated with a gloved hand.
PLUG W/CHAIN 2.5"
There shall be a South Park model HPC3008AC, 2-½" NST plug with chain supplied. The plug shall be
manufactured from high quality brass and shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
INTAKE DRAINS
Each gated intake shall be equipped with a Trident Emergency 3/4" quarter turn bleeder valve. The
bleeder valve shall be equipped with a chrome plated rectangular handle to provide a positive grip while
personnel are wearing gloves.
Revised February 28, 2011
Page 17 of 64
RAGE Pumper Demo #4000
Wildland Type III
INTAKE TRIM PLATES
Each gated intake shall have a stainless steel trim plate around the intake valve and fitting. The trim plate
shall be easily removable without the need to disturb the valve.
SLOW CLOSE MECHANISMS
Gated intakes that are 3" or larger shall be equipped with a mechanism to prevent changing the position
of the valve from full open to full close, or vice-versa, in less than 3 seconds.
INTAKE STRAINERS
Removable strainers shall be provided with each gated intake.
LEFT SIDE 2-1/2" GATED INTAKE(S)
There shall be one (1) 2-1/2" gated intake(s) provided on the left side of the pump compartment. The
intake shall be furnished with a 2-1/2" valve and 2-1/2" plumbing. The intake shall terminate with a 2-1/2"
NST female chrome swivel.
The suction valve(s), unless otherwise noted in the specifications, shall be an Akron 7800 series brass,
quarter-turn, full flow, and swing-out type. The valve shall be designed in such a manner that the action
of water against the regulating element shall not affect its position.
Each valve shall be individually attached to the manifold of the pump with stainless steel pipe. The
plumbing to the valve shall contain a minimum of elbows to keep friction loss to a minimum.
Each intake shall be totally recessed behind the pump panel to protect the valve from outside elements.
PLUG W/CHAIN 2.5"
There shall be a South Park model HPC3008AC, 2-½" NST plug with chain supplied. The plug shall be
manufactured from high quality brass and shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
RIGHT SIDE 2-1/2" GATED INTAKE(S)
There shall be one (1) 2-1/2" gated intake(s) provided on the right side of the pump compartment. The
intake shall be furnished with a 2-1/2" valve and 2-1/2" plumbing. The intake shall terminate with a 2-1/2"
NST female chrome swivel.
The suction valve(s), unless otherwise noted in the specifications, shall be an Akron 7800 series brass,
quarter-turn, full flow, and swing-out type. The valve shall be designed in such a manner that the action
of water against the regulating element shall not affect its position.
Each valve shall be individually attached to the manifold of the pump with stainless steel pipe. The
plumbing to the valve shall contain a minimum of elbows to keep friction loss to a minimum.
Revised February 28, 2011
Page 18 of 64
RAGE Pumper Demo #4000
Wildland Type III
Each intake shall be totally recessed behind the pump panel to protect the valve from outside elements.
PLUG W/CHAIN 2.5"
There shall be a South Park model HPC3008AC, 2-½" NST plug with chain supplied. The plug shall be
manufactured from high quality brass and shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
INLET, STEAMER, 5", LEFT SIDE, PUMPER
There shall be a 5" steamer inlet located on the left side of the pumper. The suction fittings shall include
a removable die cast screen to provide cathodic protection for the pump thus reducing corrosion.
One (1) 5" NST chrome plated Trident model # 01.009.4 long handle steamer cap shall be provided. The
cap(s) shall have a blind insert, and vented threads.
DISCHARGE VALVES
All discharge valves, unless otherwise noted in the specifications, shall be quarter-turn, full flow, swingout type. The flow regulating element of each valve shall not change its position under any condition of
operation involving discharge pressures to the maximum pressure of the pump. The means to prevent a
change in position shall be incorporated in the operating mechanism and shall be permitted to be
manually controlled.
LOCATION OF DISCHARGE OUTLETS
No discharge outlets larger than 2-1/2" shall be located on the pump operator's panel.
STAINLESS STEEL PLUMBING
Each valve shall be individually attached to the manifold of the pump with stainless steel pipe. The
plumbing to the valve shall contain a minimum of elbows to keep friction loss to a minimum. The use of
high pressure hose will be used in as many places as practical.
DRAIN VALVES
Each discharge 2-1/2" or larger shall be equipped with a 3/4" quarter turn Trident Emergency drain
between the valve and the discharge. There shall be a chrome plated rectangular handle provided on
each drain valve to facilitate use with a gloved hand.
Drain valves shall be located in a row just above the running board and below the pump panel on each
side of the apparatus pump compartment to reduce clutter in the pump panel area. Each drain valve shall
have a color coded bezel to match the appropriate line it is connected to. The drain valves shall be
connected to the individual valves with flexible hose that is routed in such a manner as to assure
complete drainage. Discharge from the drain valves shall be routed to below the apparatus.
Revised February 28, 2011
Page 19 of 64
RAGE Pumper Demo #4000
Wildland Type III
DISCHARGE ELBOWS
All discharges that are 2" or larger and are 42" or more above grade shall be equipped with a downward
pointing elbow of 30 degrees or more.
DISCHARGE CAPS
All discharges, except for those designated as preconnects, shall have a chrome cap. Caps for
discharges 3-1/2" and smaller shall be secured to the apparatus with suitable chains or cables.
LEFT SIDE 2-1/2" DISCHARGE
There shall be one (1) 2-1/2" NST discharge on the left side of the pump compartment. The discharge
shall be plumbed with a 2-1/2" Akron valve and 2-1/2" plumbing.
The 2-1/2" valve shall be controlled by a TSC handle directly from the valve.
DISCHARGE ADAPTER(S)
There shall be one (1) South Park model SE394505AC, 2-½" NST swivel female x 2-½" NST male 45°
adapter provided. The adapter shall be manufactured from high quality brass and the swivel shall be
attached using ball bearings. The adapter shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
CAP W/CHAIN, SOUTHPARK, 2.5"NST
There shall be one (1) 2 ½" NST South Park HCC2808AC cap(s) with chain(s) provided. The cap shall be
manufactured from high quality brass that shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
RIGHT SIDE 2-1/2" DISCHARGE
There shall be one (1) 2-1/2" NST discharge on the right side of the pump compartment. The discharge
shall be plumbed with a 2-1/2" Akron valve and 2-1/2" plumbing.
The 2-1/2" valve shall be controlled by a TSC handle directly from the valve.
DISCHARGE ADAPTER(S)
There shall be one (1) South Park model SE394505AC, 2-½" NST swivel female x 2-½" NST male 45°
adapter provided. The adapter shall be manufactured from high quality brass and the swivel shall be
attached using ball bearings. The adapter shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
Revised February 28, 2011
Page 20 of 64
RAGE Pumper Demo #4000
Wildland Type III
CAP W/CHAIN, SOUTHPARK, 2.5"NST
There shall be one (1) 2 ½" NST South Park HCC2808AC cap(s) with chain(s) provided. The cap shall be
manufactured from high quality brass that shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
RIGHT REAR 2-1/2" DISCHARGE
There shall be one (1) 2-1/2" NST discharge located at the right rear of the apparatus. The discharge
shall be plumbed with a 2-1/2" Akron valve and 2-1/2" plumbing.
DISCHARGE ADAPTER(S)
There shall be one (1) South Park model SE394505AC, 2-½" NST swivel female x 2-½" NST male 45°
adapter provided. The adapter shall be manufactured from high quality brass and the swivel shall be
attached using ball bearings. The adapter shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
CAP W/CHAIN, SOUTHPARK, 2.5"NST
There shall be one (1) 2 ½" NST South Park HCC2808AC cap(s) with chain(s) provided. The cap shall be
manufactured from high quality brass that shall be polished to remove manufacturing irregularities with a
chrome finish applied to the polished surface.
LEFT RUNNING BOARD 3/4" DISCHARGE
There shall be one (1) ¾” Babcock discharge located at the left running board of the apparatus. The
discharge shall be plumbed directly to the booster tank.
There shall be a 3/4" quarter turn valve controlled at the pump panel.
BOOSTER REEL
There shall be one (1) Hannay steel fabricated electric booster reel, with a capacity of 150' of booster
hose. The reel shall have a 1-1/2" quarter turn ball valve controlled from operator's panel and piping
connected with 1-1/2" flexible hose. An automatic brake and an auxiliary manual rewind crank shall be
supplied.
The reel shall be located above the pump left side.
RED BOOSTER REEL
One (1) booster reel(s) shall be ordered from the reel manufacturer painted standard red and shall not be
repainted to match the apparatus body.
Revised February 28, 2011
Page 21 of 64
RAGE Pumper Demo #4000
Wildland Type III
NOZZLE CLIP
There shall be an Elkhart Brass nozzle clip provided with the apparatus to be used with the booster reel.
The clip is designed to hold either a round or elliptical shape with dimensions of 1-1/2" to 1-3/4"
BOOSTER REEL GUIDE ROLLERS
The booster reel shall be equipped with three (3) set(s) of hose guide rollers.
BOOSTER REEL REWIND BUTTONS
There shall be two (2) rubber covered push button switches installed for the rewind control of the booster
reel. A switch shall be located on the both the right and the left pump panels.
BOOSTER HOSE
Three (3) 50' x 3/4" section(s) of 800# test booster hose coupled with 3/4" NST pyrolite coupling shall be
supplied.
PRECONNECT HOSE BED
The pre-connect hose bed shall be fabricated of 3/16" aluminum. It shall be bolt in easily removable to
allow access for maintenance.
The floor of the pre-connect hose bed shall be to allow for drainage and ventilation.
LEFT SIDE BULKHEAD 1-1/2" PRE-CONNECT DISCHARGE
There shall be one (1) 1-1/2" NST discharge on the left side of the pump compartment The discharge
shall be plumbed with a full-flow 2" Akron style 7820 valve. Class 1 high pressure flex hose with stainless
steel couplings shall be used in plumbing the discharge
RIGHT SIDE BULKHEAD 1-1/2" PRE-CONNECT DISCHARGE
There shall be one (1) 1-1/2" NST discharge on the right side of the pump compartment The discharge
shall be plumbed with a full-flow 2" Akron style 7820 valve. Class 1 high pressure flex hose with stainless
steel couplings shall be used in plumbing the discharge.
VERTICAL PRE-CONNECT HOSE BED DIVIDER
There shall be one (1) fixed vertical divider installed centered left to right in the pre-connect hose bed.
The split hose storage area shall allow for storage of two (2) lines.
Revised February 28, 2011
Page 22 of 64
RAGE Pumper Demo #4000
Wildland Type III
ALUMINUM PRE-CONNECT HOSE BED COVER
There shall be an aluminum non-slip treadbrite cover installed on the pre-connect hose bed.
The cover shall be provided with one (1) full length stainless steel piano style hinge that shall attach the
cover to the pre-connect hose bed.
PRE-CONNECT HOSE BED FLAPS
There shall be a vinyl end flap located on each side of the pre-connect hose bed. A black nylon strap
shall be sewn on the end flap to allow a "U" clamp style ring and quick release latch to be used for easy
removal of the end flap.
Color of vinyl flaps shall be Red
ABRADED FINISH PRE_CONNECT HOSE BED
The preconnect hose bed and dividers shall have a maintenance free abraded finish.
FRONT BUMPER 1-1/2" DISCHARGE
There shall be two (2) 1-1/2" NST discharges installed to the left and right side of the front bumper. The
discharges shall be plumbed with a 2" Akron valve and 2" plumbing. Class 1 high pressure flex hose with
stainless steel couplings shall be used in the plumbing of this discharge. Control for these discharges
shall be located directly at the front bumper.
BRASS (PAINTED) DISCHARGE SWIVEL
The front bumper discharge(s) shall be equipped with a swivel. The swivel assembly shall have a flange
that directly mounts to a standard discharge valve body and a 1-1/2" male NST end. The swivel shall
have a specially designed elbow that reduces friction loss. The swivel shall be painted the same color as
the apparatus body.
EMERGENCY SHUT OFF VALVE
There shall be a 2” Akron valve installed inside the pump module to provide an emergency shut off to the
front bumper discharges in case of damage to the plumbing.
EZ-FILL FOAM RESERVOIR REFILL SYSTEM, SINGLE TANK, 12 VOLT
The apparatus shall be equipped with a Hale EZ-Fill Foam reservoir refill system. The system shall be
compatible with Class A or Class B foam concentrate. The foam pump/electric motor shall be capable of
supplying 5 gallons per minute with a three way fill/flush valve. There shall be a panel mounted controls.
The clear suction wand shall come with a cam lock fitting wand integral strainer with a matching cam lock
fitting to be located on the pump panel along with cam lock caps. The system shall also include a top
mount high level switch.
Revised February 28, 2011
Page 23 of 64
RAGE Pumper Demo #4000
Wildland Type III
The Refill Shall Be Located on the left pump panel
FOAM PRO 1600 SINGLE FOAM SYSTEM
The apparatus shall be equipped with a Hypro Foam Pro 1600 electronic, fully automatic, variable speed,
direct injection, discharge side foam proportioning system. The system shall be capable of handling
Class A foam concentrate. The foam proportioning operation shall be based on direct measurement of
water flows, and remain consistent within the specified flows and pressures. The system shall be
equipped with a control module, suitable for installation on the pump panel. Incorporated within the motor
driver shall be a microprocessor that receives input from the system flow meter, while also monitoring
foam concentrate pump output, comparing values to ensure that the operator preset proportional amount
of foam concentrate is injected into the discharge side of the fire pump.
The control module shall enable the pump operator to activate the foam proportioning system and select
proportioning rates from 0.1% to 1.0%.
A 12 volt electric motor driven, positive displacement plunger pump shall be provided. The pump
capacity shall be 1.7 GPM (9 L/min) at 200 psi with a max operating pressure up to 400 psi (28 BAR).
The motor shall be controlled by microprocessor (mounted to the base of the pump). It shall receive
signals from the control module, and power the 1/3 hp (.25 kw) electric motor in a variable speed duty
cycle to ensure that the correct proportion of concentrate is injected into the water stream.
System capacity shall be as follows:
Foam
Concentrate
0.1%
0.2%
0.5%
1.0%
1600 Maximum
Water Flow GPM
1700
850
340
170
A full flow check valve shall be provided to prevent foam contamination of fire pump and water tank or
water contamination of foam tank.
Components of the complete proportioning system as described above shall include:

Operator control and display.

Paddlewheel flow meter.

Pump and electric motor/motor driven.

Wiring harnesses.

Low level tank switch.

Foam injection check valve.
Installation and operation manual shall be provided for the unit, along with a one-year limited warranty. A
system schematic placard and a system rating placard shall be supplied and installed in accordance with
Revised February 28, 2011
Page 24 of 64
RAGE Pumper Demo #4000
Wildland Type III
NFPA standards.
FOAM PROPORTIONING SYSTEM TESTING
The foam proportioning system shall be tested and certified after final installation as per NFPA 1901,
newest edition.
POLYPROPYLENE FOAM TANK
There shall be one (1) 20 gallon polypropylene foam tank.
There shall be one (1) pressure/vacuum vent installed on the foam tank.
There shall be one (1) drain hose connected to the foam cell. The drain shall have a 1/4 turn valve
installed inside the pump house and it shall drain below the frame rail of the chassis.
The foam tank shall be completely separate from the water tank.
Class A Foam Only
WATER TANK
The water tank shall have a capacity of 500 U.S. gallons. Certification of the tank capacity shall be
recorded on the manufacturer's record of construction and shall be provided to the purchaser upon
delivery of the apparatus.
UPF POLY TANK CONSTRUCTION
The UPF Poly-Tank ® IIE shall be constructed of 1/2" thick PT2E™ polypropylene sheet stock. This
material shall be a non-corrosive stress relieved thermoplastic, black in color, and U.V. stabilized for
maximum protection.
BOOSTER TANK
The booster tank shall be of a specific configuration and shall be so designed to be completely
independent of the body and compartments. All joints and seams shall be nitrogen welded and tested for
maximum strength and integrity. The top of the booster tank shall be fitted with removable lifting eyes
designed with a 3 to 1 safety factor to facilitate easy removal.
TANK BAFFLES
The transverse swash partitions shall be manufactured of 3/8" PT2E™ polypropylene (natural in color)
and extend from approximately 4" off the floor to just under the cover. The longitudinal swash partitions
shall be constructed of 3/8" PT2E polypropylene (natural in color) and extend to the floor of the tank
through the cover to allow for positive welding and maximum integrity. All partitions shall be equipped
with vent and air holes to permit movement of air and water between compartments. The partitions shall
be designed to provide maximum water flow. All swash partitions shall interlock with one another and be
Revised February 28, 2011
Page 25 of 64
RAGE Pumper Demo #4000
Wildland Type III
welded to each other as well as to the walls of the tank.
TANK SUMP
There shall be one (1) sump in the bottom of the water tank. The sump shall be constructed of 1/2"
polypropylene and shall be located in the left front quarter of the tank. On all tanks that require a front
suction, a 4" schedule 40 polypropylene pipe shall be installed that will incorporate a dip tube from the
front of the tank to the sump location. The sump shall be used as a combination clean-out and drain. All
tanks shall have an anti-swirl plate located approximately 2" above the sump to pre-vent air from being
entrained in the water while pumping.
TANK FILL CONNECTION
All tank fill couplings shall be backed with flow deflectors to break up the stream of water entering the
tank, and shall be capable of withstanding sustained fill rates of up to 1,000 GPM.
TANK LID
The tank lid shall be constructed of 1/2" thick PT2E™ polypropylene to incorporate a multi three-piece
locking design that allows for individual removal and inspection if necessary. The tank lid shall be
recessed 3/8" from the top of the tank and shall be welded to both sides and longitudinal partitions for
maximum integrity. Each one of the lids shall have hold downs consisting of 2" polypropylene dowels
spaced a maximum of 30" apart. These dowels shall extend through the covers and shall assist in
keeping the covers rigid under fast filling conditions. A minimum of two lifting dowels shall be drilled and
tapped 1/2" x 13" to accommodate the lifting eyes.
TANK MOUNTING
The UPF Poly-Tank IIE shall rest on the body cross members in conjunction with such additional cross
members, as required by the tank manufacturer.
The tank shall be isolated from the cross members through the use of hard rubber strips with, a minimum
Rockwell Hardness of 60 durometer. Additionally, the tank shall be supported around the entire perimeter
and captured both front and rear as well as side to side to prevent the tank from shifting during vehicle
operation.
Although the tank shall be designed on a free floating suspension principle, it shall be required that the
tank have adequate hold down restraints to minimize movement during vehicle operation.
The tank shall be completely removable without disturbing or dismantling the apparatus structure.
LIFETIME TANK WARRANTY
The tank shall have a lifetime warranty from UPF.
Revised February 28, 2011
Page 26 of 64
RAGE Pumper Demo #4000
Wildland Type III
WATER TANK FILL TOWER
The tank shall have a combination vent and manual fill tower marked "Water Fill." The fill tower shall be
constructed of 1/2" PT2E polypropylene and shall be a minimum dimension of 8" x 8" at the outer
perimeter. The tower shall be located in the left front corner of the tank. The tower shall have a 1/4" thick
removable polypropylene screen and a PT2E polypropylene hinged-type cover.
UPF TANK OVERFLOW
The tank shall be equipped with a minimum of a 4" schedule 40 polypropylene overflow/air vent pipe.
The pipe shall be installed in the fill tower and extend through the tank and dump to the rear of the rear
axle.
TANK DRAIN VALVE
One (1) 1-1/2" tank drain valve(s) shall be provided under the tank sump.
WATER TANK LEVEL GAUGE
The apparatus shall be equipped with one (1) Class1 " Intelli-Tank " level gauge on the pump operators
control panel. The tank level gauge shall indicate the water level on an easy to read LED display and
show increments of 1/8 of a tank.
The tank level gauge system shall include:
1) A pressure transducer that is mounted on the outside of the tank in an easily accessible area.
2) A super bright LED 4-light display with a visual indication at nine accurate levels.
3) A set of weather resistant connectors to connect to the digital display, to the pressure transducer and
to the apparatus power.
WATER TANK LEVEL GAUGE, MINI SLAVE, IN THE CAB
In addition to the Class1 master water level tank gauge on the pump operator’s panel, there shall be a
remote mini dash mounted gauge supplied in the chassis cab. The gauge shall mimic the master units
display by reading the appropriate information on the 1-wire data transfer line.
CONTROL PANEL
The left side of the pump enclosure shall be divided into two sections. The lower section shall be where
all valve controls, the primer control, and other mechanical controls are located. This surface shall be
referred to as the "control panel".
All valve controls shall be the self locking type, activated by either direct control or with a direct linkage
utilizing friction locking bell cranks and universal ball swivels. The primary valve handles shall have color
coded tags installed in a recessed area to clearly denote the purpose of each control.
Revised February 28, 2011
Page 27 of 64
RAGE Pumper Demo #4000
Wildland Type III
INSTRUMENT PANEL
The surface above the control panel shall contain all instruments, gauges, test fittings, and optional
controls. This surface shall be referred to as the "instrument panel". The instrument panel shall be
independent and hinged and latched so that it may be opened. All instruments, gauges, and other
equipment shall be installed with sufficient slack in any cabling, tubing, or plumbing to allow the panel to
swivel to the fully open position.
The instrument and gauge panel shall be vertically hinged " swing out " to provide access for service.
COLOR CODED LABELS
To improve identification of discharges and intakes, color coded tags shall be provided. The tags shall
utilize an etching process to provide easy visibility and improved field service life. Tags shall be affixed
using an industrial grade adhesive backing, eliminating the need for pop rivets or screws into the panel or
control handle.
RIGHT SIDE PUMP PANEL
A single panel shall be installed on the right side of the pump enclosure. This shall be the area where
any right side discharges, inlets, steamers, and other pump associated equipment are located. This
panel shall be easily removable and held in place with quick release push latches. It shall be fully
removable for pump and plumbing access without the need to use hand tools. Any electrical equipment
that may be installed shall be equipped with connectors so they may be easily separated from the
opening created when the below described front access panel is removed.
PUMP PANEL LIGHTS - ON SCENE
The pump operator's control panel and the right side pump panel shall each be illuminated by a On Scene
LED night stik lighting,
The pump panel lights shall become energized upon setting the parking brake so the gauge information
provided may be consulted at any time the apparatus is parked.
A stainless steel shield shall be installed over the pump panel lights to further protect them from the
elements and to act as a reflector for additional illumination.
PANEL SURFACES
The control panel, instrument panel, and right side pump panel shall be fabricated from
a minimum of 14 gauge stainless steel with #4 brushed finish.
PRESSURE/VACUUM TEST PORTS
Class1 model 115100 pressure and vacuum test ports shall be provided on the pump panel.
Revised February 28, 2011
Page 28 of 64
RAGE Pumper Demo #4000
Wildland Type III
PUMP COOLER VALVE
Class1 model 38BV pump cooling control valve shall be provided on the pump panel.
ENGINE COOLER VALVE
Class1 model 38BV engine cooling control valve shall be provided on the pump panel.
WHITE FACE/ BLACK NUMERAL GAUGE DISPLAY
The master pump gauges and individual pressure gauges shall have a white face with black numbers and
lettering. This shall provide a high contrast and allow the gauges to be easily read by the operator.
CLASS 1 INSTRUMENT PANEL MASTER PUMP GAUGES, PSI
The pump vacuum and pressure gauges shall be supplied by Class 1. Each gauge shall be Interlube filled
to insure proper operations to minus 40 degrees. The master intake gauge shall read -30-0-600 PSI and
the master discharge gauge shall read 0-600 PSI. The gauges shall be a minimum of 3-1/2" in diameter.
PUMP COMPARTMENT
The main body and the pump compartment shall be fabricated as a single unit. Both the body and pump
compartment shall be fabricated using precision holding fixtures to ensure proper dimensions. All
attachment points shall be heavily reinforced.
GALVANNEAL BODY CONSTRUCTION
The apparatus body shall be fabricated from 12 gauge Galvaneal steel. The complete apparatus body
shall be fabricated utilizing the break and bend techniques in order to form a strong, yet flexible, uni-body
structure. The body shall be constructed with holding fixtures to ensure proper dimensioning. Each
apparatus body shall is specific in design in order to meet the unique requirements of the purchasing fire
department.
Continuous, solid welded seams shall be located at the upper front and upper rear corners of the
apparatus body. The flooring of all lower, main body compartmentation shall also have solid weld seams.
All door jams, on both the top and the bottom, shall be solid welded as well. Each main door jam shall
consist of a double jam design, this is comparable to a double struck frame design, which provides
superior strength and durability. All double door jams are to be welded together utilizing the plug weld
technique. All remaining compartment walls shall be stitch welding.
The body design shall include a “false wall” design in the lower portion of each lower, rear compartment.
This is required in order to allow for easy accessibility to the rear electrical components found in the rear
taillight cluster area.
The upper area of the apparatus body, directly above the side compartment door openings, a header is to
be fabricated from 12 gauge Galvaneal steel. This area shall be free from any body seams and shall be
painted the same color as the apparatus body. The height of the header may vary depending on the
following factors: apparatus design, lettering requirements, scene lights and warning light requirements as
Revised February 28, 2011
Page 29 of 64
RAGE Pumper Demo #4000
Wildland Type III
well as various other options.
BODY SUB FRAME
To assure proper body alignment and clearance, the body sub frame shall be constructed in a jig and
fitted directly on the chassis.
The chassis frame rails shall be fitted with fiber reinforced rubber to isolate the body frame members from
direct contact with chassis frame rails.
The main body sub frame shall be constructed from steel tubing. The sub frame shall run the full length
of the body and shall be spaced the same width as the chassis frame rails. The main sub frame shall
also be the integral support for the water tank. Vertical drop tubes shall be welded to the sub frame.
From these vertical drop tubes shall extend cross members constructed of steel angle. These cross
members shall extend out to support the compartments. Cross members shall be located at the front
and rear of the body and in front and rear of the wheel well opening.
The compartment area behind the rear axle shall be supported by a drop frame fabricated of steel tube
and steel angles. The rear drop frame shall be constructed using vertical drop tubes, welded to the main
sub frame. All drop frame structures shall be welded directly to the body sub frame to allow the body to
be a completely separate structure from the chassis.
After fabrication the sub frame shall be painted black for protection against corrosion.
BODY MOUNTING
The body sub frame shall be fastened to the chassis frame with a minimum of six (6) spring loaded body
mounts. Each mount shall be configured using a two-piece bracket. The two (2) brackets shall be
fabricated of steel plates. The plates shall be painted to prevent any corrosion. Each mounting assembly
shall utilizing two (2) plated bolts and two (2) heavy duty springs. The rear of the body shall be secured
utilizing a single point pivot assembly. The pivot assembly shall be designed to allow the chassis frame,
sub frame, and body to "twist" independently. The assembly design shall allow the body and sub frame to
act as one (1) component, separate from the chassis. As the chassis frame twists under driving
conditions, the spring mounting system shall limit any stress from being transferred into the body. The
spring loaded body mounts shall also prevent frame side rail or body damage caused by unevenly
distributed stress and strains due to load and chassis movement.
Body mountings that does not allow relief from chassis movement shall not be acceptable.
TANK MOUNTING
The water tank shall rest on the sub frame cross members which are spaced as required by the tank
manufacturer.
The tank shall be isolated from the cross members through the use of hard rubber strips with a minimum
Rockwell hardness of 60 durometer. Additionally, the tank shall be supported around the entire perimeter
and captured both front and rear as well as side to side to prevent the tank from shifting during vehicle
operations.
Although the tank shall be designed on a free floating suspension principle, it shall be required that the
Revised February 28, 2011
Page 30 of 64
RAGE Pumper Demo #4000
Wildland Type III
tank have adequate hold down restrains to minimize movement during vehicle operations.
The tank shall be completely removable without disturbing or dismantling the apparatus structure.
SINGLE AXLE CONFIGURATION
The apparatus shall have a single rear drive axle configuration.
LEFT SIDE COMPARTMENTS
COMPARTMENT L1
There shall be an upper compartment located over the rear wheel on the left side of the apparatus body.
This compartment shall be designated as L1 within these specifications and any ensuing paperwork or
drawings after contract execution. The compartment shall be equipped with a single, horizontally hinged
lift-up door.
Door opening - 62" wide x 29" high
The compartment shall have a usable depth 13.25".
COMPARTMENT L2
There shall be a full height compartment located behind the rear wheels on the left side of the apparatus
body. This compartment shall be designated as L2 within these specifications and any ensuing paperwork
or drawings after contract execution. The compartment shall be equipped with a single, vertically hinged
swing-out door.
Door opening - 29" wide x 54.5" high
The compartment shall have a usable depth of 13.25" in the upper portion and 23.75” in the lower portion.
COMPARTMENT CL1
There shall be a compartment located below the rear crew doors on the left side of the chassis. This
compartment shall be designated as CL1 within these specifications and any ensuing paperwork or
drawings after contract execution. It shall be equipped with a double, vertically hinged swing-out door.
Door opening - 36" wide x 12" high
The compartment shall have a usable depth of 12".
RIGHT SIDE COMPARTMENTS
COMPARTMENT R1
There shall be an compartment located ahead of the rear wheel on the right side of the apparatus body.
This compartment shall be designated as R1 within these specifications and any ensuing paperwork or
drawings after contract execution. It shall be equipped with a single, vertically hinged swing-out door.
Revised February 28, 2011
Page 31 of 64
RAGE Pumper Demo #4000
Wildland Type III
Door opening - 11" wide x 46.5" high
The compartment shall have a usable depth of 22".
COMPARTMENT R2
There shall be an compartment located over the rear wheel on the right side of the apparatus body. This
compartment shall be designated as R2 within these specifications and any ensuing paperwork or
drawings after contract execution. It shall be equipped with a single, horizontally hinged lift-up door.
Door opening - 62" wide x 29" high
The compartment shall have a usable depth of 13.25" .
COMPARTMENT R3
There shall be a full height compartment located behind the rear wheels on the right side of the apparatus
body. This compartment shall be designated as R3 within these specifications and any ensuing
paperwork or drawings after contract execution. It shall be equipped with a single, vertically hinged
swing-out door.
Door opening - 29" wide x 54.5" high
The compartment shall have a usable depth of 13.25" in the upper portion and 23.75 in the lower portion.
COMPARTMENT CR1
There shall be a compartment located below the rear crew doors on the right side of the chassis. This
compartment shall be designated as CR1 within these specifications and any ensuing paperwork or
drawings after contract execution. It shall be equipped with a double, vertically hinged swing-out door.
Door opening - 36" wide x 12" high
The compartment shall have a usable depth of 12".
NON-TRANSVERSE REAR COMPARTMENTS
Bulkheads shall be installed in the back of the lower left and right side compartments to separate them
from the rear facing, low compartment.
REAR COMPARTMENT
There shall be a full height compartment located at the rear of the apparatus body. This compartment
shall be designated as T1 within these specifications and any ensuing paperwork or drawings after
contract execution. It shall be equipped with a double vertically hinged swing-out door.
Door Opening - 42" Wide x 40" High
Revised February 28, 2011
Page 32 of 64
RAGE Pumper Demo #4000
Wildland Type III
The compartment shall have a usable depth of 27".
COMPARTMENT SCUFF PLATES
Anodized aluminum angle scuff plates shall be installed in the bottom sill area of all major equipment
carrying compartments to reduce paint damage from equipment. The scuff plates shall be attached using
a permanent bonding double sided tape.
COMPARTMENT DOOR CONSTRUCTION
The lap type compartment doors shall be of double panel construction. The outer panel shall be
fabricated of .190, 5052-H32 aluminum and the inner panel of .125, 3003-H14 aluminum. There shall be
a heavy-duty automotive type extruded rubber molding installed on the overlap area of the doors to insure
a weatherproof seal and prevent water from collecting in the door sills. All of the compartment doors
shall have a polished stainless steel continuous hinge connected to both the body and the door with
stainless steel bolts and nuts. The hinge pin shall be stainless steel with a minimum diameter of 1/4".
COMPARTMENT LOCKING DOOR HANDLES, DOUBLE PAN DOORS
Compartment door handles shall be locking stainless steel recessed "D" ring type handles. There shall
be a safety latch with striker plate included with the door handle assembly.
# 1250 Key
COMPARTMENT DOOR HOLDERS, SPRING LOADED
Cleveland style spring loaded door holders shall be furnished on all vertically hinged, swing-open
compartment doors to hold the door in either the fully open or partially closed position. The spring-loaded
door holder shall close the door automatically when it is positioned past center or return the door to the
fully open position if the center point is not reached and the door is released.
On compartments having double doors, the secondary door shall have a latch mechanism to secure the
door when the primary door is opened.
The door strut attachment tabs will be designed in such a way to prevent them from cracking or breaking
due to stress.
COMPARTMENT DOOR HOLDERS, PNEUMATIC
Pressurized gas filled cylinders shall be furnished on all horizontally hinged, lift-up compartment doors to
hold the door in the open position and assist in raising it. The gas filled cylinders shall assist in closing
the door automatically when the door is positioned over center.
ON SCENE VL SERIES COMPARTMENT LIGHTING
All compartments that are equipped with a lap style door and have an opening of less than 42" shall be
furnished with one (1) On Scene Solutions VL series LED compartment light mounted on the front corner
Revised February 28, 2011
Page 33 of 64
RAGE Pumper Demo #4000
Wildland Type III
of the compartment.
All compartments that are equipped with a lap style door and have a door opening that is 42" wide or
wider shall have a One (1) On Scene Solutions VL series LED light installed on the front and rear corner
of the compartment.
The lights shall be rated at 100,000 hours of service. The light shall be enclosed in tough 5/8" Lexan
tube. Multi-clip attachment shall allows for installation into any roll up, or standard door configuration.
An automatic door switch shall activate the compartment lights.
NFPA STEP REQUIREMENTS
All steps shall have a surface area of at least 35 square inches and shall be able to withstand a load of at
least 500 pounds. Steps shall be provided at any area that personnel may need to climb and shall be
adequately lighted.
STEPS, CAST PRODUCTS
All steps shall have a surface area of at least 35 square inches and shall be able to withstand a load of
1,000 pounds. Steps shall be provided at any area that personnel may need to climb and shall be
adequately lighted. Each folding step shall have two large open slots to prevent buildup of ice or mud and
to provide a handhold when necessary.
Steps shall be provided in the following locations:
Six (6) steps at the rear of the body, three (3) on each side.
WALKWAY LIGHT, LED, GROTE
There shall be two (2) light(s) provided to illuminate the walkway and/or compartment area. The light
housing shall be stainless steel and is completely encapsulated in order to provide maximum
environmental protection.
FOLD DOWN AUXILIARY BELOW REAR DECK
There shall be an fold down auxiliary step located below the rear deck to assist in the safe climbing onto
the apparatus.
A holding fixture shall be provided to secure the step in the up position to prevent damage to the step.
COMPARTMENT VENTING
Each body compartment shall be properly vented in a manner that will reduce the amount of dirt and
water that may enter the compartment. Venting shall be directly to the atmosphere rather than into
another compartment, which would only spread moisture throughout the body rather than dissipate it.
The vent opening, which is located in the lower corner of the compartment, shall have a filter which is
easily removable to allow cleaning it
Revised February 28, 2011
Page 34 of 64
RAGE Pumper Demo #4000
Wildland Type III
Additionally, each compartment shall be equipped with drain holes to allow standing water to exit.
HEAT DEFLECTOR SHIELD, EXHAUST
Increased standards for emission have caused most exhaust temperatures to increase. To keep the
exhaust heat from adversely affecting anything stored in the body, a deflector shield shall be provided to
aid in dissipating the heat.
HATCH COMPARTMENT - LEFT SIDE
There shall be a hatch compartment located on top of the left side high compartments. The compartment
shall be constructed as an integral part of the apparatus body
Door Opening - 10" Wide x 94" Long
The compartment shall have a usable depth of 18.5
.
HATCH COMPARTMENT - RIGHT SIDE
There shall be a hatch compartment located on top of the right side high compartments. The
compartment shall be constructed as an integral part of the apparatus body.
Door Opening - 10" Wide x 94" Long
The compartment shall have a usable depth of 18.5
LEFT SIDE INTEGRAL RUNNING BOARD
An integral running board shall be installed on the left side of the pump compartment module. The
running board shall be over lain with non-slip treadbrite. The outside edge of the running board shall be
flush with the rub rail that is installed on the body to maintain a uniform appearance.
All running boards shall be installed with sufficient support to form a sturdy, non-deflecting step area for
personnel.
LEFT RUNNING BOARD BAR GRATE INSERT
There shall be a bar grate insert fabricated into the step area of the left running board.
RIGHT SIDE INTEGRAL RUNNING BOARD
An integral running board shall be installed on the right side of the pump compartment module. The
running board shall be over lain with non-slip treadbrite. The outside edge of the running board shall be
flush with the rub rail that is installed on the body to maintain a uniform appearance.
All running boards shall be installed with sufficient support to form a sturdy, non-deflecting step area for
personnel.
Revised February 28, 2011
Page 35 of 64
RAGE Pumper Demo #4000
Wildland Type III
RIGHT RUNNING BOARD BAR GRATE INSERT
There shall be a bar grate insert fabricated into the step area of the right running board.
MODULAR REAR DECK
A modular bolt-on deck shall be installed on the rear of the apparatus to form a full width step area. The
rear deck shall be constructed of non-slip treadbrite. The outside edge of the rear deck shall
be flush
with the rub rail that is installed on the body to maintain a uniform appearance.
All running boards shall be installed with sufficient support to form a sturdy, non-deflecting step area for
personnel.
REAR STEP BAR GRATE INSERT
There shall be a Bar Grate insert fabricated into the step area of the rear step.
ULTRA STAINLESS™ MARUTEX® SCREWS
Stainless steel screws shall be provided throughout the body in locations such as: overlays, pump panels,
and other numerous hardware mounting locations. In these locations the following screw specification
shall apply.
The special ingredient in Ultra Stainless™ is Marutex®, which adds 2% molybdenum (moly) to 410
stainless. Moly is the significant component of 316 stainless that provides extra corrosion resistance.
The moly is now added to 410 self drilling screws to produce Ultra Stainless™. This combination
provides for unprecedented corrosion resistance combined with hardness for drilling.
Marutex® screws are tempered and quenched; regular T-140 self-drilling screws are case hardened. The
additional carbon in Marutex® provides hardness for better drilling.
In certified testing the Marutex® screws have shown far superior corrosion resistance than that of 410
stainless, and 304 Bimetal screws. The screws were tested using two methods, the first was a 500 hour
salt spray test, and the second was the European Air Pollution Test using the Kesterich method. In this
test a combination of condensation water and atmosphere containing sulfur dioxide was sprayed on the
screws. In both tests the Marutex® screws did not show any signs of rust, the 410 and 304 samples on
the other hand did.
As part of quality control standards, samples from each batch of Ultra Stainless™ Marutex® screws shall
be subject to a salt spray test for a minimum of 2500 hours. The test results shall be provided at any time
upon request by the customer.
STEPPING, STANDING, WALKING SURFACES
All exterior surfaces designated by the manufacturer as stepping, standing, or walking areas shall be
constructed of grip strut or textured treadbrite and shall provide a highly slip resistant surface, even when
the surface is wet. All interior surfaces designated by the manufacturer as stepping, standing, or walking
Revised February 28, 2011
Page 36 of 64
RAGE Pumper Demo #4000
Wildland Type III
areas shall be slip resistant when the surface is dry.
The degree of slip resistance shall be in compliance with the intent of NFPA 1901 newest version.
It is the desire of the fire department to purchase an apparatus that utilizes aluminum treadplate as an
overlay of the main apparatus body structure. Aluminum treadplate may also be utilized in the
construction of enclosure doors, lids and covers where applicable. Aluminum treadplate is not to be
utilized as a main structural member of the apparatus body or pump enclosure.
TREADBRITE OVERLAYS
There shall be aluminum treadbrite overlays installed on the apparatus in those areas designated as
walking areas or where additional scuff protection of the apparatus finish is desired.
The top treadbrite overlay shall be mounted flush with the outer edges of the apparatus body. A "J"
channel shall be incorporated into the design in order to provide a rain gutter to further assist in
preventing excessive moisture from getting into the compartments.
Overlays shall be totally insulated from the apparatus with nylon shoulder washers that extend into the
hole that is drilled into the body. Stainless steel cap nuts shall be employed where bolts may damage
equipment or cause injury. After painting and final construction overlays shall be additionally sealed at
the edges with a caulking compound.
Front compartment vertical areas on both sides.
REAR WHEEL WELLS
The fenders shall be integral with the body sides and compartments with a seamless appearance. The
fenders shall be fitted with bolt-in removable full circular inner liners in the wheel well area for ease of
cleaning and maintenance. There shall be sufficient clearance provided in the wheel well to allow the use
of tire chains when the apparatus fully loaded.
REAR FENDERETTES-RUBBER
Two (2) rubber fenderettes shall be installed at the outboard edge of the rear wheel well area, one on
each side.
BODY RUB RAILS
Rub rails shall be installed beneath the compartment doors to protect them from damage should the body
be brushed or rubbed against another object. The rub rails shall be 3/16 inch aluminum channel, 2-1/2
inch x 1 inch. The rub rails shall be highly polished and then Bright Dip anodized.
It shall be installed on the body utilizing non-corrosive nylon spacers and secured with stainless steel
bolts. The outside edge of the rub rails shall be even with the fenderettes and bolt-on steps to prevent
snagging.
Revised February 28, 2011
Page 37 of 64
RAGE Pumper Demo #4000
Wildland Type III
REAR TOW EYE
One (1) rear tow eyes shall be installed directly below the rear of the chassis frame rails. The tow eye
shall be capable of a 15,000 lb. straight pull rating.
HANDRAILS
All handrails, unless otherwise stated, shall be constructed of knurled aluminum of not less than 1-1/4" in
diameter. All railing shields and brackets shall be chrome plated, and shall be bolted to the body with
stainless steel bolts. The lower bracket on all vertical handrails shall have a drain hole drilled in it at the
lowest point.
Horizontal rear hand rail above the rear center compartment.
Left rear vertical hand rail from top of body to just above the upper rear step.
Right rear vertical hand rail from top of body to just above the upper rear step.
TURTLE TILES
There shall be Turtle Tiles provided with the apparatus. The tiles shall be black in color. When installed
in compartments, yellow leading edges shall be provided. The tiles shall be installed as follows:
Compartments: all
Shelves in Compartments: all
SHELVING CHANNELS
There shall be four (4) strut channels, two (2) per side, installed in three (3) standard height
compartment(s) for future shelves.
The strut channels shall be installed L1, R2, T1
SHELVING CHANNELS
There shall be two (2) strut channels, one (1) per side, installed in two (2) full height compartment(s) for
future shelves.
The strut channels shall be installed: L2,R3
ADJUSTABLE SHELVES
There shall be three (3) adjustable shelves installed on the apparatus. The shelves shall be
constructed of 3/16" aluminum sheet with 2" lips. The shelves shall have an abraded finish. The shelves
shall be designed in such a manner that will allow liquids to readily drain when spilled.
The shelves shall be installed:
Revised February 28, 2011
Page 38 of 64
RAGE Pumper Demo #4000
Wildland Type III
One (1) L2 Lower Full Depth
One (1) R3 Lower Full Depth
One (1) T1
ROLL OUT EQUIPMENT TRAY(S)
There shall be one (1) roll out equipment tray(s) installed on the apparatus which will be equipped with
Austin Hardware drawer slides. The roller assembly shall have a rated capacity of 300 lbs. distributed
load and have 100% extension capabilities. The tray(s) shall be constructed of 3/16" aluminum sheet
with 3" lips to prevent items from being shifted during transportation. The tray(s) shall have an abraded
finish. The tray(s) shall also be equipped with a gas spring in order to hold the tray in either a fully
extended or closed position.
The roll-out trays shall be installed in the left side chassis compartment.
CHANNELS MOUNTED ON REAR COMPARTMENT WALL, FOR SCBA BRACKETS
There shall be one (1) set(s) of strut channels installed on the rear compartment wall for mounting of
SCBA brackets. This shall allow for full movement of the brackets along the entire width of the
compartment.
The channels shall be located R2
AIR BOTTLE COMPARTMENT
There shall be four (4) single cylinder air bottle compartment(s) installed in the rear wheel well area. The
tube(s) shall be constructed from injection molded plastic to assist in preventing damage to the air
cylinder(s). There shall be a drain hole in the rear of the compartment.
AIR BOTTLE COMPARTMENT DOOR
The single air bottle compartment shall have a stainless steel FireShopp hinged door. All hinges and
mounting hardware shall be concealed. A Southco latch shall be utilized for opening and securely closing
the door. Weather stripping will also be provided to keep the inside of the compartment dry.
LEFT/RIGHT WHEEL CHOCK STORAGE COMPARTMENT
There shall be a wheel chock storage compartment installed in the left and right rear wheel well area.
The compartments will be fabricated out of aluminum. The interior of the compartment is to have an
abraded finish. There shall be a drain hole in the rear of the compartment.
COMPARTMENT DOORS
The storage compartment shall have a vertically hinged aluminum door. The door shall be a single pan
design and shall be positively latch in the closed position utilizing a push button latch. The door shall be
painted the color of the apparatus body.
Revised February 28, 2011
Page 39 of 64
RAGE Pumper Demo #4000
Wildland Type III
The wheel chock compartments shall be located behind the rear wheel wells one left and one right.
WHEEL CHOCKS
There shall be one (1) pair of Cast Products, Inc. wheel chocks provided with the apparatus. The chocks
shall be located one in each wheel chock compartment that are provided in the specifications.
HOSE BED CAPACITY
The hosebed shall have the capacity for 55 cubic feet of hose.
HOSE BED
The hose bed compartment shall have a minimum of 30 cubic feet of storage space in accordance with
NFPA latest edition 1901.
HOSE BED FLOORING
The floor of the hose bed compartment shall be constructed of Dura-Dek fiber reinforced plastic material.
The flooring shall be fabricated of "T" beam pultrusions in parallel connected with cross slats that are first
mechanically bonded and then epoxied, forming a large sheet.
The top portion of each "T" cross section shall measure 1-1/4" wide and 3/16" thick with beaded ends.
The vertical portion shall be 3/8" thick, beading out at the bottom to a thickness of 1/2" and tall enough to
result in an overall height of 1". The "T" sections shall be spaced 3/4" apart to allow for drainage and
ventilation.
Each "T" beam shall be constructed utilizing a core of 250,000 continuous glass fiber strands that are
high in resistance to tension, compression and bending. An outer sheath consisting of a continuous
strand mat to prevent lineal splitting and shipping shall surround the core. The sheath shall also serve to
draw the protective resin to the bar surface. Both reinforcements shall be
pulled through an
isophthalic polyester resin, treated with antimony trioxide for fire resistance, to form a solid length.
The flooring shall then be protected with a polyurethane coating to screen out ultraviolet rays. This bright
white coating shall be baked on and shall provide a pleasing contrast when installed in the apparatus.
ALUMINUM HOSE BED PARTITION(S)
One (1) hose bed partition(s) shall be installed in the hose bed. The partition(s) shall be fabricated from
1/4" smooth aluminum plate and an aluminum extrusion.
The partition(s) shall be mounted on hot-dipped galvanized slide rails at the front and rear of the hose
bed.
Where no obstruction such as a fill tower is present, the slide rails shall allow full movement of the
partition along the width of the hose bed. Each hose bed partition shall have an oval shaped hand hold
slot to assist in moving the partition. This shall provide the capability for variable hose load configurations
Revised February 28, 2011
Page 40 of 64
RAGE Pumper Demo #4000
Wildland Type III
& capacities.
The hose bed divider shall be located to the left of the ladder / hard suction storage compartment.
ADJUSTABLE SPLIT HOSE STORAGE DIVIDERS
There shall be two (2) adjustable hose storage dividers. The dividers shall be mounted on strut channels
to allow the dividers to be moved forward and aft in the hose bed.
The split hose bed divider shall be located to the right of the ladder / hard suction storage compartment.
ABRADED FINISH HOSE BED DIVIDER
Three (3) adjustable hose bed divider(s) shall have a maintenance free abraded finish.
POWER OPERATED ALUMINUM HOSE BED COVER
The hose bed storage area shall be covered with two (2) hinged aluminum doors. The doors shall be
hinged on the outside edges, utilizing full length stainless steel piano hinges. The doors shall lift up and
out towards the outside of the body. The doors shall be fabricated with 1/8" aluminum inner panel for
superior strength. The outside sheet shall be constructed of non-slip treadbrite.
The hose bed doors shall be power operated utilizing a self-contained hydraulic system. The system
pressure of the hydraulic system shall be factory set to a pressure that will smoothly power the cover
doors upward and downward. The system is designed to keep the doors firmly open when reloading
hose as well as to hold the cover doors firmly down in the travel position. Mechanical locks are not
required in order to avoid possible injury from accidental closing of cover doors.
Hydraulic cylinders, located in front of the hose bed storage area shall be utilized to open and close the
cover doors. The hydraulic system shall be powered by a Monarch Hydraulics power unit. The hydraulic
system shall be designed so the doors only operate in the predetermined factory-set sequence. The
system shall only allow one door at a time to move. The cylinders, when the doors are in the closed
position, shall lower into a secluded compartment that is separate from the stored hose to ensure
unobstructed hose deployment operations. The cylinder pins attached to the doors shall be designed to
be removable with the doors in the closed position without having to climb inside the hose storage area.
Self-contained switches shall be utilized to raise and lower the cover doors independently. The switches
shall be located at the rear of the apparatus in a convenient location allowing the operator to view the
hose bed cover doors while operating the mechanism from ground level. The switches shall be the
momentary type of switch that requires the operator to hold the switch until the desired movement of the
cover doors is achieved.
The power unit shall be interlocked with the parking brake and shall be operable only when the parkbrake is applied. The doors shall be connected to the open door warning system when in the open
condition. An audible alarm shall be located towards the front of the hose bed area designed to warn
possible occupants of the hose bed area that door movement is occurring.
Revised February 28, 2011
Page 41 of 64
RAGE Pumper Demo #4000
Wildland Type III
HOSE BED COVER LIGHTS, WHELEN, LED
Two (2) Whelen model 20C0CDCR LED lights shall be installed on the inside of each hose bed cover
door. The lights shall be activated when the door is opened.
VINYL FLAP ON END OF HOSE BED COVER
There shall be a vinyl end flap located at the rear of the hose bed cover. A black nylon strap shall be
sewn on the end flap to allow a "U" clamp style ring and quick release latch to be used for easy removal
of the end flap.
The vinyl flap shall be red.
I-ZONE BRACKET
There shall be I-zone bracket(s) provided on the rear of the body. The brackets shall be constructed of
stainless steel with a removable extension rods.
HARD SUCTION HOSE STORAGE CENTER OF HOSE BED
Provisions shall be made to provide storage for Three (3) 4” hard suction hose in the hose bed, along
with an extension ladder The hard hose shall be accessible through a vertically hinged double door at the
rear of the apparatus. In addition there shall be provisions for two (2) pike poles.
ALUMINUM TUBES FOR PIKE POLE STORAGE
There shall be two (2) aluminum tube(s) for storage of pike pole(s)
HARD SUCTION HOSE, FIREQUIP
The following hard suction hose shall be supplied by body builder at the time of delivery:
Three (3) 4" X 8' length(s) of flexible PVC suction hose.
One (1) 20' three section ladder(s), Duo-Safety 912-100
WIRING HARNESSES
Wiring harnesses shall be the automotive type, engineered specifically for the builder's apparatus, and
shall meet the following criteria. Under no circumstances shall diodes, resistors, or fusible links be
located within the wiring harness. All such components shall be located in an easy to access wiring
junction box or the main circuit breaker area. All wire shall meet white book, baseline advanced design
transit coach specification and Society of Automotive Engineers recommended practices. It shall be
stranded copper wire core with cross linked polyethylene insulation complying with SAE specification
J1128. Each wire shall be hot stamp function coded every three inches starting one inch from the end
and continuing throughout the entire harness. In addition to function coding, each wire shall be number
and color coded.
Revised February 28, 2011
Page 42 of 64
RAGE Pumper Demo #4000
Wildland Type III
All terminals on the ends of the wiring harness shall be soldered unless a crimping tool or machine is
used that gives an even and precise pressure for the terminal being used. All terminals shall be pull
tested to insure their integrity.
12 VOLT ELECTRICAL SYSTEM
The 12 volt electrical system shall utilize the Navistar Diamond Logic system.
12 VOLT SYSTEM SCHEMATIC
A complete electrical schematic for the apparatus shall be provided. This schematic shall be specifically
prepared for this individual unit rather than a generic schematic designed to accommodate all apparatus.
12 VOLT SYSTEMS TEST
After completion of the unit, the 12 volt electrical system shall undergo a battery of tests as listed in the
latest addition of NFPA Pamphlet 1901. These tests shall include, but not be limited to: a reserve
capacity test, alternator performance test at idle, alternator performance test at full load, and a low
voltage alarm test. Certification of the results shall be supplied with the apparatus at the time of delivery.
REAR WORK LIGHT SWITCH
A switch shall be installed above the tail light bezel on the left side. The switch shall be wired to the
backup lights to provide additional work lighting. The rear work light circuit shall be deactivated when the
park brake is disengaged. In addition to the lights being activated by the above switch, the lights shall
also come on when the transmission is placed in reverse.
LED CLEARANCE LIGHTS
Grote model 65282 red LED clearance lights shall be installed on the rear of the body as necessary to be
in full compliance with applicable ICC and DOT codes and regulations.
GROUND LIGHTING - WHELEN, LED, PUMPERS
There shall be four (4) Whelen model 20C0CDCR LED lights installed beneath the apparatus in areas
where personnel may be expected to climb on and off of the apparatus. The lights shall illuminate the
ground within 30" of the apparatus to provide visibility of any obstructions or hazards. These areas shall
include, but not be limited to, side running boards and the rear step area.
WALKWAY LIGHTS
Lights shall be mounted in a manner that illuminates all walkways and steps for safe operation of the
apparatus. These lights shall become illuminated when the parking brake is engaged.
Revised February 28, 2011
Page 43 of 64
RAGE Pumper Demo #4000
Wildland Type III
PUMP COMPARTMENT LIGHTS, WHELEN, LED
There shall be two (2) Whelen model 20C0CDCR LED lights installed in the pump compartment. The
lights shall be activated by an automatic switch in the right side pump compartment access door and shall
be located in a manner that will provide maximum lighting.
TAIL LIGHTS
There shall be a LED tail light assembly installed on each side of the rear of the apparatus. Each
assembly shall include one (1) red Supernova 4” round grommet mounted LED stop/tail light, one (1)
amber Supernova 4” round grommet mounted LED turn light and one (1) clear 4” Supernova 4” round
grommet mounted halogen backup light.
HANDHELD SPOTLIGHT
There shall be one (1) Collins CL-12 handheld spotlight installed in the cab in an area that is easily
accessible to the front passenger. The light shall be equipped with a momentary switch. A bracket shall
be provided to hold the light when not in use.
12 VOLT SCENE LIGHT(S)
There shall be Two (2) 12v scene lights mounted on the front of the chassis hood of the apparatus.
SCENE LIGHT SWITCH IN CAB
The scene lights shall be controlled by a switch located in the cab within reach of the driver. The switch
shall have an indicator to which shall illuminate when the switch is in the “ON” position. The switch shall
be labeled "FRONT SCENE LIGHTS.”
12 VOLT SCENE LIGHTS ( REAR )
There shall be two (2) Whelen M6ZC Scenelight(s) with bezel, installed on the rear of the apparatus.
REAR SCENE LIGHT SWITCH IN CAB, W/REVERSE, & AT THE REAR
The rear scene lights shall be controlled by a switch located in the chassis within reach of the driver. The
switch shall have an indicator which shall illuminate when the switch is in the “ON” position. One switch
shall control all of the rear scene lights if multiple scene lights are selected. The switch shall be labeled
"REAR SCENE.”
In addition to the switch located in the cab, the rear scene lights shall be activated by the rear work light
switch, and when the apparatus is placed in reverse.
12 VOLT SCENE LIGHTS (LEFT )
There shall be one (1) Whelen M6ZC Scenelight(s) with bezel, installed on the left side of the apparatus.
Revised February 28, 2011
Page 44 of 64
RAGE Pumper Demo #4000
Wildland Type III
LEFT SCENE LIGHT SWITCH IN CAB
The rear scene lights shall be controlled by a switch located in the cab within reach of the driver. The
switch shall have an indicator to which shall illuminate when the switch is in the “ON” position. One
switch shall control all of the rear scene lights if multiple scene lights are selected. The switch shall be
labeled "LEFT SCENE.”
12 VOLT SCENE LIGHTS (LEFT )
There shall be one (1) Whelen M6ZC Scenelight(s) with bezel, installed on the right side of the apparatus.
RIGHT SCENE LIGHT SWITCH IN CAB
The rear scene lights shall be controlled by a switch located in the cab within reach of the driver. The
switch shall have an indicator to which shall illuminate when the switch is in the “ON” position. One
switch shall control all of the rear scene lights if multiple scene lights are selected. The switch shall be
labeled "RIGHT SCENE.”
12 VOLT POWER LEAD
There shall be two (2)12 volt power leads provided in specified compartments. The power leads shall
terminate at a terminal block located in the compartment. A minimum of a 20 amp breaker shall be
provided with each power circuit.
The 12 volt terminal blocks shall be located in the center console.
One (1) battery constant
One (1) Battery Switched
12 VOLT ACCESSORY OUTLET IN THE CAB
There shall be two (2)12 volt accessory outlet provided in the cab.
The accessory outlets shall be located on the front of the center console.
PROTECTIVE COVERS AND ENCLOUSRES FOR ELECTRICAL TERMINALS
All ungrounded electrical terminal shall have a protective cover or be in an enclosure.
UPPER ZONE A VISUAL WARNING
There shall be one (1) Whelen Engineering model SLN2VLED, 54" long Liberty light bar installed on the
chassis cab roof. The lightbar shall be equipped with two (2) forward facing linear "Red" LED's, two (2)
forward facing linear "White" LED's, two (2) corner forward facing "Red" LED's, and two (2) corner rear
Revised February 28, 2011
Page 45 of 64
RAGE Pumper Demo #4000
Wildland Type III
facing "Red" LED's,
The lightbars shall be equipped with clear lenses. All clear LEDs in the lightbar shall be deactivated in
the Blocking Right of Way mode.
UPPER ZONE B VISUAL WARNING
There shall be one (1) Whelen Engineering model LINZ6R installed in the upper warning zone. The
lights shall have a clear lenses with red LEDs.
UPPER ZONE C VISUAL WARNING
There shall be two (2) Whelen Engineering model LINZ6R installed in the upper warning zone. The
lights shall have a clear lenses with red LEDs.
UPPER ZONE D VISUAL WARNING
There shall be one (1) Whelen Engineering model LINZ6R installed in the upper warning zone. The
lights shall have a clear lenses with red LEDs.
LOWER ZONE A VISUAL WARNING
There shall be two (2) Whelen Engineering model LINZ6R installed in the lower warning zone. The lights
shall have a clear lens with red LEDs.
LOWER ZONE B VISUAL WARNING
There shall be two (2) Whelen Engineering model LINZ6R installed in the lower warning zone. The lights
shall have a clear lens with red LEDs.
LOWER ZONE C VISUAL WARNING
There shall be two (2) Whelen Engineering model LINZ6R installed in the lower warning zone. The lights
shall have a clear lens with red LEDs.
LOWER ZONE D VISUAL WARNING
There shall be two (2) Whelen Engineering model LINZ6R installed in the lower warning zone. The lights
shall have a clear lens with red LEDs.
AIR HORNS, WHEEL WELL MOUNTED
There shall be Grover 1512 stutter tone dual air horns mounted in the right side front fender well of the
chassis. The air horns shall be connected to the chassis air brake system through a low pressure
protection valve that will prevent the use of the air horns when the air brake system pressure is below 80
Revised February 28, 2011
Page 46 of 64
RAGE Pumper Demo #4000
Wildland Type III
PSI.
AIR HORN ACTIVATION
The air horn shall be activated by the chassis steering wheel horn button.
AIR HORN BUTTON ON PUMP PANEL
One (1) air horn button shall be provided on the pump panel.
ALTERNATING HEADLIGHT FLASHERS
Alternating headlight flashers shall be installed with a control switch on the chassis electrical module.
The flasher shall control the high beam lamps only. When the headlights are on and switched to high
beam, the flasher shall be overridden.
WHELEN "LED" TRAFFIC ADVISOR
There shall be one (1) Whelen model TAL65W "LED" Traffic Advisor installed on the apparatus. The
traffic advisor shall contain six medium intensity LED lamps. The traffic advisor shall be recess mounted
on the rear of the body above the rear compartment. A deluxe controller shall be supplied and installed in
the cab to control the traffic advisor.
The control head shall be located in the center console.
INTERIOR COMPARTMENT COATING
Amerlock 400 is an epoxy self-priming topcoat
Amerlock 400 is a high (80-85%) solids, two part epoxy paint that is unsurpassed in performance
does not require a topcoat
Semigloss
Amerlock’s low solvent level meets VOC requirements
• LowVOC
• High-performance general maintenance coating for new or old steel
• Cures through wide temperature range
• Self-priming topcoat over most existing coatings
• Can be overcoated with wide range of topcoats
• Compatible with prepared damp surfaces
• Compatible with adherent rust remaining on prepared surfaces
• 5mils or more in a single coat
• Resists high humidity and moisture
• Temperature resistance to 450°F on insulated or uninsulated
Surfaces when mixed with Amercoat 880 glass flake additive
• Can be applied to substrates with temperatures up to 250°F
Revised February 28, 2011
Page 47 of 64
RAGE Pumper Demo #4000
Wildland Type III
BODY COMPARTMENTATION COATING COLOR
The interior of the body compartments shall be painted off white.
BODY PAINT PREPARATION
After the body and components have been fabricated and assembled they shall then be disassembled
prior to painting so when the apparatus is completed there shall be finish paint beneath the removable
components. The body shall be totally removed from the chassis during the painting process to insure
the entire unit is covered. The apparatus body and components shall be metal finished as follows to
provide a superior substrate for painting.
All Galvanneal steel sections of the body shall undergo a five-step degreasing/cleaning process starting
with an alkaline cleaner to degrease the metal surface and then rinsed. Next a phosphoric acid rinse
shall be performed to begin the etching process. A phosphatizer shall is applied to continue the etching
process and deposit a protective film on the metal surface. The last step shall consist of a non-chromatic
rinse to seal the protective film and rinse off excess solution. All aluminum surfaces shall undergo the
last four steps in the cleaning process since degreasing of the metal is not needed.
After the cleaning process the body and its components shall be primed with an High Solids primer and
the seams shall be caulked.
All bright metal fittings, if unavailable in stainless steel or polished aluminum, shall be heavily chrome
plated. Iron fittings shall be copper underplated prior to chrome plating.
PAINT PROCESS
The paint process shall follow the strict standards as set forth by PPG Fleet Finish Guidelines.
The body shall go through a three-stage paint process: primer coat, base coat ( color ), and clear coat. In
the first stage of the paint process the body shall be coated with PPG F3980 Low VOC / High Solids
primer to achieve a total thickness of 2-4 mills. In the second stage of the paint process the body shall be
painted with PPG FBCH Delfleet™ High Solids Polyurethane Base Coat. A minimum of two to three
coats of paint shall be applied to achieve hiding. In the final stage of the paint process the body shall be
painted with PPG DCU-2002 Clear Coat. A minimum of two to three coats shall be applied to achieve a
total dry film thickness of 2-3 mills.
As part of the curing process the painted body shall go through a Force Dry / Bake Cycle process. The
painted components shall be baked at 185 degrees for 3 hours to achieve a complete coating cure on the
finished product.
HAND POLISHED
After the force dry / bake cycle and ample cool down time, the coated surface shall be sanded using 3M
1000, 1200, and or 1500 grit sandpaper to remove surface defects. In the final step, the surface shall be
buffed with 3M superduty compound to add extra shine to coated surface. No more than .5 mil of clear
shall be removed in this process.
Revised February 28, 2011
Page 48 of 64
RAGE Pumper Demo #4000
Wildland Type III
APPARATUS BODY COLOR
The apparatus shall be painted with PPG High Solids Polyurethane Base Coat.
The apparatus shall be painted ( RED ) PPG# FBCH - 71096-ALT.
CORROSION PREVENTION
One (1) 3.75 ounce shall be provided to use whenever additional items are mounted to the apparatus.
ECK protects aluminum and stainless steel against electrolytic reaction, isolates dissimilar metals and
gives bedding protection for hardware and fasteners. ECK contains anti-seizing lubricant for threads. ECK
is dielectric and perfect for use with electrical connectors.
NFPA COMPLIANT REFLECTIVE STRIPING
Reflective striping shall be applied to the exterior of the apparatus in a manner consistent with the
National Fire Protection Association Pamphlet 1901, latest edition. It shall consist of a straight, 4" wide
stripe along the front of the chassis and along the sides, staying below the tops of the wheel well areas.
The reflective striping shall be white in color.
CHEVRON REFLECTIVE STRIPING, REAR OF UNIT
In addition to the custom striping pattern supplied on the apparatus, there shall be additional reflective
striping applied to the entire rear of the unit. The reflective striping shall cover at least 50% of the rear
facing vertical surface, per NFPA 1901 newest edition.
The striping shall consist of alternating red and yellow, fluorescent yellow or fluorescent yellow-green
reflective stripes. Each stripe shall be a minimum of 6" in width and shall be applied to the apparatus at
45° angle.
CHEVRON REFLECTIVE STRIPING, RED/FLUORESCENT YELLOW
The chevron striping shall consist of 3M part numbers 1172 EC, red and 3983, fluorescent yellow-green.
CAB DOOR REFLECTIVE STRIPING
A minimum of 96 sq. in. of reflective striping shall be applied to the interior of each cab door.
The reflective striping shall be red / fluorescent yellow green Chevron in color.
RUB RAIL REFLECTIVE STRIPING
There shall be 2" reflective striping installed in the rub rail channel. The reflective striping shall
diamond grade quality material for increased visibility. The reflective shall be silver in color.
Revised February 28, 2011
Page 49 of 64
be
RAGE Pumper Demo #4000
Wildland Type III
PAINT, PUMPER, UNDERSIDE
The underside of the apparatus shall be painted.
MUD FLAPS (4)
There shall be two (2) mud flaps at the front of the chassis which are provided by the custom chassis
supplier. Two (2) more at the rear of the unit will be provided by the apparatus manufacturer. The mud
flaps shall be a minimum of 3/8" thick to prevent "sailing".
ZICO BRACKET WITH PHS STRAP
There shall be four (4) Zico KD-UN-6-SF, bracket(s) with PHS strap(s) installed in the following
compartment(s)
BATTERY CHARGER
A Dual Pro Power, 120volt, 20 amp, (10 amps per bank)model # Dual Pro Power 10x2, automatic battery
charger shall be installed and wired to the shoreline receptacle and the chassis batteries. The charger
shall be a fully automatic waterproof system. Each bank of the charging system shall be capable of
producing a charge to bring the batteries back to full charge. The unit shall turn off when the battery is at
full charge and turn on automatically if the battery voltage drops. There shall be a charge indicator display
provided on the charger. The unit shall have as standard a Three Year Warranty.
REMOTE CHARGE INDICATOR
A Dual Pro Power Remote Charge Indicator shall be provided in a remote location to show what the
status of the charge on the batteries.
SHORELINE RECEPTACLE 20 AMP, 125V, MANUEL EJECT
A flush mount 20 Amp, 125V manual eject shoreline receptacle shall be installed on the left side of the
chassis cab by the driver's door.
AIR BRAKE REFILL INLET WITH CHECK VALVE
An air inlet shall be located near the driver's door. This fitting shall be connected to the air brake system
"wet" tank to allow a remote air source to maintain a usable pressure in the chassis brakes. A check
valve shall be provided as part of the system.
EJECT, MANUAL, FOR AIR INLET
The Air Inlet shall be supplied with a manual eject.
Revised February 28, 2011
Page 50 of 64
RAGE Pumper Demo #4000
Wildland Type III
BACK-UP ALARM
The backup alarm shall be an Ecco 510 Dba type. The sound level shall be 87 decibels.
HAZARD WARNING CIRCUIT
The open compartment door circuitry shall be tied into the open passenger door warning light circuitry of
the chassis to warn the driver of an unsafe condition. Also connected to this circuit shall be any other
compartment door, device or other item which may pose a hazard or cause damage should the apparatus
be moved. The hazard warning circuit shall only become energize when the chassis parking brake is
released.
A warning sign shall be placed near the warning light that reads "Do Not Move Apparatus When Light Is
On."
ELECTRONIC SIREN
There shall be one (1) Code 3 model 3692, 200 watt, electronic siren installed in the cab. Full features of
the siren shall include Wail, Yelp, Hi -Lo, Air Horn, and a hard-wired microphone.
SIREN SPEAKER
There shall be one (1) Federal Dyna-Max aluminum 100 watt speaker(s) recessed in the front bumper.
The model number MS100 speaker shall be mounted utilizing an MSFMT mounting bracket and
hardware.
NFPA RECOMMENDED TOP SPEEDS
GVWR OVER 26,000 LBS. (11,800 KG): The maximum top speed shall not exceed either 68 MPH (105
km/hr) or the tire manufacturer's maximum fire service speed rating, whichever is lower.
GVWR OVER 50,000 LBS. (22,680 KG): The maximum top speed shall not exceed either 60 MPH (85
km/hr) or the tire manufacturer's maximum fire service speed rating, whichever is lower.
FOAM & WATER TANK CAPACITY EXCEEDS 1,250 GALLONS (4,732 L): The maximum top speed
shall not exceed either 60 MPH (85 km/hr) or the tire manufacturer's maximum fire service speed rating,
whichever is lower.
SWITCH PANEL
There shall be one (1) switch panel provided between the front bucket seats in the cab. The panel shall
be large enough to accommodate twelve (12) separate switches.
FLOOR MOUNTED CONSOLE
There shall be a floor mounted console provided between the officer and drivers seats. The console shall
be used for mounting of siren controls and department supplied radio equipment. The console shall be
Revised February 28, 2011
Page 51 of 64
RAGE Pumper Demo #4000
Wildland Type III
covered in black Line-X.
TILT TABLE TESTING
The apparatus shall be tested to verify the stability to 26.5 degrees in both directions.
The apparatus shall be tested while loaded with fuel, fire fighting agents, hose, ladders, weight of 250 lbs.
per seat, and also weight that is equivalent to the miscellaneous equipment that will be carried. The
weight added to the apparatus for testing purposes shall be distributed approximately to the in-service
use, yet not to exceed the manufacturer's compartment ratings.
HELMETS STORED IN CAB
Space shall be made available to allow the mounting of brackets for helmets in the cab area.
HELMET BRACKETS, DEALER OR CUSTOMER SUPPLIED
The dealer or customer shall supply brackets for mounting helmets in the chassis cab. These brackets
shall comply with NFPA 1901, newest edition.
ENGINE COMPARTMENT WORK LIGHT
One (1) 12 volt work light shall be installed in the chassis engine compartment.
BATTERY SYSTEM DISCONNECT
There shall be a battery system disconnect switch provided within easy reach of the driver.
BATTERY JUMPER STUDS
There shall be a pair of battery jumper studs provided on the drivers side of the apparatus. The studs
shall allow the vehicle to be jump started in an emergency due to battery failure.
GROUND LIGHTING -WHELEN, LED, PUMPERS
There shall be four (4) Whelen model 20C0CDCR LED lights installed beneath the chassis in areas
where personnel may be expected to climb on and off of the apparatus. The lights shall illuminate the
ground within 30" of the apparatus to provide visibility of any obstructions or hazards.
BAR GRATE ] FOR CAB STEP / FUEL TANK
A bar grate step assembly shall be installed on the chassis step and fuel tank.
FIRE EXTINGUISHER
Revised February 28, 2011
Page 52 of 64
RAGE Pumper Demo #4000
Wildland Type III
There shall be a 2.5 lb. BC DOT approved fire extinguisher shipped loose in the cab of the apparatus.
ROAD SAFETY KIT
There shall be one (1) road safety kit provided with the apparatus. The kit shall consist of three (3) DOT
approved reflective triangles.
FUEL TANK VENTING
The fuel tank vent shall be extended.
EXTERIOR CHASSIS CAB TRIM
There shall be rubber skirting material provided below the chassis cab on the left and right side of the
body to prevent debris from getting into the exposed are below the chassis cab.
AIR INTAKE SCHREENS
There shall be stainless steel mesh installed over the air intake screens of the chassis cab.
FUEL TANK SKID PLATE
There shall be an 1/8” steel skid plate below the chassis fuel tank. The skid plate shall be painted black.
CHASSIS EXHAUST MODIFICATION
The exhaust for the chassis shall be routed to the rear right side of the apparatus
FRONT TOW EYE PLATE
There shall be tow eye plate installed on the front of the chassis extended front bumper. The plate shall
be constructed of ½” plate steel with a 3” x 4” tow eye in the center of the plate and shall extend outward
from the front bumper
HOSE ROLLER MOUNT
There shall be an 2” receiver installed on the front and rear to provide a mounting location for a hose
roller assembly.
MAP CONSOLE
There shall be a map console installed in the chassis cab. The console shall be 9" tall, 13" wide and 10"
deep. The console shall hold three (3) binders up to 2-1/2" thick. The map console shall be constructed
Revised February 28, 2011
Page 53 of 64
RAGE Pumper Demo #4000
Wildland Type III
of aluminum and shall have an abraded finish. The map console shall be mounted between the drivers
and officers seats.
Mount on the rear of the center console.
ENCLOSED SEAT COMPARTMENTS IN CHASSIS CAB
The storage area below the rear crew seats shall be enclosed with horizontally hinged doors to provide
additional storage compartments. The doors shall be constructed of aluminum, and Line-X coated black.
There shall be a compression latch provided on each door.
20" FRONT BUMPER EXTENSION
The front bumper shall be extended 20" from the front surface of the chassis cab. The space between
the bumper and the cab shall be covered with a gravel shield of treadbrite aluminum with gaps provided
where needed to allow for chassis frame rail movement. Support for the gravel shield shall be installed to
provide a strong, steady area for personnel while servicing the apparatus.
THREE STORAGE WELLS IN BUMPER
There shall be Three (3) storage wells in the extended front bumper. The wells shall be located on the
left, center, and right side of the bumper and shall be as large as practical. The floor shall be covered
with Turtle Tile
FRONT BUMPER HOSE COMPARTMENT COVER(S)
There shall be one (1) aluminum treadbrite cover(s) installed on the center front bumper hose
compartment(s).
AIR OUTLET
There shall be one (1) 1/4" quick connect female air outlet. This outlet shall be used for filling tires
fire extinguishers. The air outlet shall be located on the left side pump panel.
or
MANUFACTURING LABELS
A permanent plate shall be mounted in the driver's compartment specifying the quantity and type of the
following fluids that may be used in the apparatus for normal maintenance. Where a fluid is not applicable
to the unit, the plate shall be marked N/A to inform the service technician who may not be familiar with the
apparatus.





Engine oil
Engine coolant
Transmission fluid
Pump transmission fluid
Pump primer fluid
Revised February 28, 2011
Page 54 of 64
RAGE Pumper Demo #4000
Wildland Type III










Drive axle fluid
Air conditioning refrigerant
Power steering fluid
Cab tilt mechanism fluid
Transfer case fluid
Equipment rack fluid
Air compressor system lubricant
Generator system lubricant
Front tires air pressure
Rear tires air pressure
A permanent plate shall be affixed in the driver's area that states the maximum number of personnel
allowed to ride on the apparatus at any time.
A sign shall be affixed in the chassis cab, in plain sight of the driver that states the overall travel height,
overall length, and gross GVWR of the apparatus.
On any gated inlet on the apparatus, a permanent label shall be provided that states:
"WARNING: Death or serious injury might occur if proper operating procedures are not followed. The
pump operator as well as individuals connecting supply or discharges hoses to the apparatus must be
familiar with water hydraulics hazards and component limitations."
All other appropriate labels to ensure safe operation of the apparatus shall be permanently affixed in
conspicuous locations.
BASE CHASSIS, MODEL 7400 4X4
TOW HOOK, FRONT (2) Inside Rail, Frame Mounted.
FRAME RAILS Heat Treated Alloy Steel (120,000 PSI Yield); 10.125" x 3.580" x 0.312" (257.2mm x
90.9mm x 8.0mm); 480.0" (12192) Maximum OAL
BUMPER, FRONT Full Width, Aerodynamic, Steel, Painted 0001 Canyon Black; 0.189" Material
Thickness
FRAME EXTENSION, FRONT Integral; 20" In Front of Grille
WHEELBASE RANGE 148" (375cm) Through and Including 179" (455cm)
AXLE, FRONT DRIVING {Meritor MX-12-120} Single Reduction, 12,000-lb Capacity
DRAIN PLUG, DRIVING FRONT AXLE Magnetic
AXLE, FRONT DRIVING, LUBE {EmGard 75W-90} Synthetic Oil; 1 thru 29.99 Pints
SUSPENSION, FRONT, SPRING Parabolic, Taper Leaf; 12,000-lb Capacity; With Shock Absorbers
SPRING PINS Rubber Bushings, Maintenance-Free
BRAKE SYSTEM, AIR Dual System for Straight Truck Applications
Revised February 28, 2011
Page 55 of 64
RAGE Pumper Demo #4000
Wildland Type III
BRAKE LINES Color and Size Coded Nylon
DRAIN VALVE Twist-Type
DUST SHIELDS, FRONT BRAKE
DUST SHIELDS, REAR BRAKE
GAUGE, AIR PRESSURE (2) Air 1 and Air 2 Gauges; Located in Instrument Cluster
PARKING BRAKE CONTROL Yellow Knob, Located on Instrument Panel
PARKING BRAKE VALVE For Truck
QUICK RELEASE VALVE Bendix On Rear Axle for Spring Brake Release: 1 for 4x2, 2 for 6x4
SLACK ADJUSTERS, FRONT Automatic
SLACK ADJUSTERS, REAR Automatic
SPRING BRAKE MODULATOR VALVE R-7 for 4x2, SR-7 with relay valve for 6x4
DRAIN VALVE, AUTOMATIC {Bendix DV-2} With Heater; for Air Tank
DRAIN VALVE Mounted in Wet Tank
AIR BRAKE ABS {Bendix AntiLock Brake System} Full Vehicle Wheel Control System (4-Channel) With
Automatic Traction Control
AIR DRYER {Bendix AD-IP} With Heater
BRAKE CHAMBERS, FRONT AXLE {Haldex} 20 SqIn
BRAKE CHAMBERS, REAR AXLE {Haldex GC3030LHDHO} 30/30 Spring Brake
BRAKE CHAMBERS, SPRING (2) Rear Parking; WITH TRUCK BRAKES: All 4x2, 4x4; WITH
TRACTOR
BRAKES: All 4x2, 4x4; 6x4 & 6x6 with Rear Tandem Axles Less Than 46,000-lb. or GVWR Up To
54,000-lb.
BRAKES, FRONT, AIR CAM S-Cam; 16.5" x 5.0"; Includes 20 Sq. In. Long Stroke Brake Chambers
BRAKES, REAR, AIR CAM S-Cam; 16.5" x 7.0"; Includes 30/30 Sq.In. Long Stroke Brake Chamber and
Spring Actuated Parking Brake
AIR COMPRESSOR {Bendix Tu-Flo 550} 13.2 CFM Capacity
STEERING COLUMN Tilting and Telescoping
STEERING WHEEL 2-Spoke, 18" Diam., Black
STEERING GEAR {Sheppard M-100} Power
Revised February 28, 2011
Page 56 of 64
RAGE Pumper Demo #4000
Wildland Type III
EXHAUST SYSTEM Single, Horizontal, Aftertreatment Device Frame Mounted Left Side Under Cab
HORIZONTAL TAIL PIPE, Provides Clean CA Above & Below Rail
The Horizontal Tailpipe Includes a Temperature Control Device
ENGINE EXHAUST BRAKE for MaxxForce I6 Engines, Electronically Activated
SWITCH, FOR EXHAUST 2 Position, Lighted & Latching, ON/OFF Type, Mounted in IP, Inhibits Diesel
Particulate Filter Regeneration as Long as Switch is in ON Position
ELECTRICAL SYSTEM 12-Volt, Standard Equipment
BATTERY BOX Steel with Fiberglass Cover
DATA LINK CONNECTOR For Vehicle Programming and Diagnostics In Cab
FUSES, ELECTRICAL SAE Blade-Type
HAZARD SWITCH Push On/Push Off, Located on Top of Steering Column Cover
HEADLIGHT DIMMER SWITCH Integral with Turn Signal Lever
HEADLIGHTS (2) Sealed Beam Halogen, 5" X 7" Rectangular, with Chrome Plated Bezels
HORN, ELECTRIC Single
JUMP START STUD Located on Positive Terminal of Outermost Battery
PARKING LIGHT Integral with Front Turn Signal and Rear Tail Light
RUNNING LIGHT (2) Daytime, Included With Headlights
STARTER SWITCH Electric, Key Operated
STOP, TURN, TAIL & B/U LIGHTS Dual, Rear, Combination with Reflector
TURN SIGNAL SWITCH Self-Cancelling for Trucks, Manual Cancelling for Tractors, with Lane
Change Feature
TURN SIGNALS, FRONT Includes Reflectors and Auxiliary Side Turn Signals, Solid State
Flashers; Flush Mounted
WINDSHIELD WIPER SWITCH 2-Speed with Wash and Intermittent Feature (5 Pre-Set Delays),
Integral with Turn Signal Lever
WINDSHIELD WIPERS Single Motor, Electric, Cowl Mounted
WIRING, CHASSIS Color Coded and Continuously Numbered
CIGAR LIGHTER Includes Ash Cup
Revised February 28, 2011
Page 57 of 64
RAGE Pumper Demo #4000
Wildland Type III
HORN, ELECTRIC (2)
TOGGLE SWITCH, AUXILIARY and Wiring to Front Bumper, For Driving Lights or Fog Lights Mounted by
Customer
IGNITION SWITCH Keyless
ALTERNATOR {Leece-Neville 14931PAH} Brush Type, 12 Volt 320 Amp. Capacity, Pad Mounted
BODY BUILDER WIRING Back of Standard Cab at Left Frame or Under Extended or Crew Cab at Left
Frame; Includes Sealed Connectors for Tail/Amber Turn/Marker/ Backup/Accessory Power/Ground and
Sealed Connector for Stop/Turn
BATTERY SYSTEM {JCI} Maintenance-Free (3) 12-Volt 2100CCA Total
BACK-UP ALARM Electric, 102 dBA
TRAILER CONNECTION SOCKET 7-Way; Mounted at Rear of Frame, Wired for Turn Signals
Independent of Stop, Compatible With Trailers That Have Amber or Side Turn Lamps
DATA RECORDER Less Display
JUMP START STUD Remote Mounted
JUMP START STUD Mounted to Battery Box
HORN, AIR Black, Single Trumpet, Air Solenoid Operated
BATTERY DISCONNECT SWITCH {Joseph Pollak} for Cab Power Disconnect Switch; Lever Operated,
Disconnects Power to PDC, Does Not Disconnect Charging Circuits, Cab Mounted
HEADLIGHTS Long Life Halogen; for Two Light System
SWITCH, BODY CIRCUITS, REAR for Bodybuilder; With 6 Switches in Instrument Panel (2-position
switches); One Power Module, With 6 Channels, 20 Amp per Channel and 80 Amp Max Output, Switches
Control the Power Modules Through Multiplex Wiring, Mounted at Rear of Frame
STARTING MOTOR {Delco Remy 38MT Type 300} 12 Volt; less Thermal Over-Crank Protection
INDICATOR, LOW COOLANT LEVEL With Audible Alarm
INDICATOR, BATTERY WARNING Green BATTERY ON Indicator, Mounted on Left Side of Instrument
Panel, To be Used with Factory Installed or Customer Mounted Battery Disconnect Switch
CIRCUIT BREAKERS Manual-Reset (Main Panel) SAE Type III With Trip Indicators, Replaces All Fuses
Except For 5-Amp Fuses
FENDER EXTENSIONS Rubber
INSULATION, UNDER HOOD for Sound Abatement
Revised February 28, 2011
Page 58 of 64
RAGE Pumper Demo #4000
Wildland Type III
GRILLE Stationary, Chrome
INSULATION, SPLASH PANELS for Sound Abatement
INTERNATIONAL LOGOS Ship Loose International Door Badges in Cab for Installation after Customer
Graphics
GRILLE EMBER SCREEN Mounted to Grille to Keep Hot Embers out of Engine Air Intake System
FRONT END Tilting, Fiberglass, With Three Piece Construction; for 2007 Emissions
PAINT SCHEMATIC, PT-1 Single Color, Design 100
PAINT SCHEMATIC ID LETTERS "GM"
PAINT IDENTITY, PT-2 Single Color, Instruction No. 936. Frame/Running Gear, Less Fuel Tanks
NOTE: Battery Box, Air Tanks, Fuel Tanks, Steps and Straps NOT Painted
PAINT TYPE Base Coat/Clear Coat, 1-2 Tone
PAINT CLASS Single Custom Color
KEYS,- ALL ALIKE, ID Z-001
CLUTCH Omit Item (Clutch & Control)
ENGINE, DIESEL {MaxxForce 9} EPA 10, 330 HP @ 2000 RPM, 950 lb-ft Torque @ 1200 RPM, 2200
RPM Governed Speed
AIR COMPRESSOR AIR SUPPLY LINE Naturally-Aspirated
COLD STARTING EQUIPMENT Intake Manifold Electric Grid Heater with Engine ECM Control
CRUISE CONTROL Electronic; Controls Integral to Steering Wheel
ENGINE OIL DRAIN PLUG Magnetic
ENGINE SHUTDOWN Electric, Key Operated
FUEL FILTER Included with Fuel/Water Separator
FUEL/WATER SEPARATOR Fuel/Water Separator and Fuel Filter in a Single Assembly; With
Water-in-Fuel Sensor; Engine Mounted
GOVERNOR Electronic
OIL FILTER, ENGINE Spin-On Type
WET TYPE CYLINDER SLEEVES
Revised February 28, 2011
Page 59 of 64
RAGE Pumper Demo #4000
Wildland Type III
FAN DRIVE {Horton Drivemaster Polar Extreme} Direct Drive Type, Two Speed, With Residual Torque
Device for Disengaged Fan Speed
FAN Nylon
RADIATOR Aluminum, Front to Back Cross Flow, Series System; 1663 SqIn Core and 885 SqIn Charge
Air Cooler and 470 SqIn Low Temperature Radiator Down Flow
ANTI-FREEZE Red Shell Rotella Extended Life Coolant -40F (-40C)
DEAERATION SYSTEM with Surge Tank
HOSE CLAMPS, RADIATOR HOSES Gates Shrink Band Type; Thermoplastic Coolant Hose
Clamps
RADIATOR HOSES Premium, Rubber
FEDERAL EMISSIONS for 2010; MaxxForce 9 & 10 Engines
AIR CLEANER Single Element
GAUGE, AIR CLEANER RESTRICTION Air Cleaner Mounted
THROTTLE, HAND CONTROL Engine Speed Control for PTO; Electronic, Stationary Pre-Set, Two
Speed Settings; Mounted on Steering Wheel
ENGINE CONTROL, REMOTE MOUNTED Provision for; Includes Wiring for Body Builder Installation of
PTO Controls; With Ignition Switch Control for MaxxForce post 2007 Emissions Electronic Engines
ENGINE WATER COOLER {Sen-Dure} Auxiliary, For Use With Fire Trucks
EMISSION COMPLIANCE Engine Shutdown System Exempt Vehicles, Complies With California Clean
Air Regulations
TRANSMISSION, AUTOMATIC {Allison 3000EVS_P} 4th Generation Controls; Close Ratio, 5-Speed;
With Overdrive, Includes Oil Level Sensor, With Provision for PTO, Less Retarder, Max. GVW N/A
OIL FILTER, TRANSMISSION Mounted on Transmission
TRANSMISSION OIL PAN Magnet in Oil Pan
TRANSFER CASE {Meritor T-4210 2} 2 Spd, 10000 lb-ft Total Capacity, With Provision for PTO, With
Electric Over Air Control
LIGHT, INDIC, ALL-WHEEL DRIVE Illuminates With All Wheel Drive Engaged, Located on
Instrument Panel
OIL COOLER, AUTO TRANSMISSION {Modine} Water to Oil, for Allison or CEEMAT Transmission
TRANSMISSION SHIFT CONTROL {Allison} Push-Button Type; for Allison 3000 & 4000 Series
Transmission
Revised February 28, 2011
Page 60 of 64
RAGE Pumper Demo #4000
Wildland Type III
TRANSFER CASE LUBE {EmGard 50W} Synthetic; 1 thru 14.99 Pints
OIL COOLER, TRANSFER CASE Remote Mounted Back of Cab
ALLISON SPARE INPUT/OUTPUT for Emergency Vehicle Series (EVS); Fire/Pumper, Tank,
Aerial/Ladder
SHIFT CONTROL PARAMETERS Allison Performance Programming in Primary and Allison Economy
Programming in Secondary
AXLE, REAR, SINGLE {Meritor RS-23-161} Single Reduction, 23,000-lb Capacity, 200 Wheel Ends,
Driver Controlled Locking Differential . Gear Ratio: 4.89
REAR AXLE DRAIN PLUG (1) Magnetic, For Single Rear Axle
SUSPENSION, RR, SPRING, SINGLE Vari-Rate; 23,500-lb Capacity
SHOCK ABSORBERS, REAR (2)
FUEL TANK Top Draw; D Style, Non Polished Aluminum, 19" Deep, 50 U.S. Gal., 190 L Capacity,
Beveled Back of Tank, With Quick Connect Outlet, Mounted Left Side, Under Cab
CAB Conventional 6-Man Crew Cab
ARM REST (2) Molded Plastic; One Each Door
CLEARANCE/MARKER LIGHTS (5) Flush Mounted
COAT HOOK, CAB Located on Rear Wall, Centered Above Rear Window
CUP HOLDERS Two Cup Holders, Located in Lower Center of Instrument Panel
DOME LIGHT, CAB Rectangular, Door Activated and Push On-Off at Light Lens, Timed Theater
Dimming, Integral to Console, Center Mounted
GLASS, ALL WINDOWS Tinted
GRAB HANDLE, CAB INTERIOR (1) "A" Pillar Mounted, Passenger Side
GRAB HANDLE, CAB INTERIOR (2) Front of "B" Pillar Mounted, One Each Side
GRAB HANDLE, CAB INTERIOR (4) Two Each Side, Rear Door Mounted at Hinge Side and "C"
Pillar Mounted
INTERIOR SHEET METAL Upper Door (Above Window Ledge) Painted Exterior Color
STEP (8) Two Steps Per Door
GAUGE CLUSTER English With English Electronic Speedometer
GAUGE CLUSTER (6) Engine Oil Pressure (Electronic), Water Temperature (Electronic), Fuel
(Electronic), Tachometer (Electronic), Voltmeter, Washer Fluid Level
Revised February 28, 2011
Page 61 of 64
RAGE Pumper Demo #4000
Wildland Type III
ODOMETER DISPLAY, Miles, Trip Miles, Engine Hours, Trip Hours, Fault Code Readout
WARNING SYSTEM Low Fuel, Low Oil Pressure, High Engine Coolant Temp, and Low Battery
Voltage (Visual and Audible)
SEATBELT WARNING PREWIRE Includes Seat Belt Switches and Seat Sensors for all Belted Positions
in the Cab and a Harness Routed to the Center of the Dash for the Aftermarket Installation of the Data
Recorder and Seatbelt Indicator Systems, for 4 to 6 Seat Belts
GAUGE, OIL TEMP, ALLISON TRAN
GAUGE, AIR CLEANER RESTRICTION {Filter-Minder} With Black Bezel Mounted in Instrument Panel
IP CLUSTER DISPLAY On Board Diagnostics Display of Fault Codes in Gauge Cluster
SEAT, DRIVER {Gra-Mag} Non-Suspension, High Back With Integral Headrest, Vinyl, With Fixed Back
SEAT BELT 3-Point, Lap and Shoulder Belt Type
SEAT, PASSENGER {Gra-Mag} Non Suspension, High Back, Fixed Back, Integral Headrest, Vinyl
SEAT BELT 3-Point, Lap and Shoulder Belt Type
SEAT, REAR {International} BENCH; Full Width; Vinyl, With Fixed Back and Two Integral Outboard
Headrests
SEAT BELT (3) Two 3-Point Shoulder Belts for Driver and Outer Passenger and One 2-Point Lap
Belt for Center Passenger
GRAB HANDLE (2) Chrome Towel Bar Type With Anti-Slip Rubber Inserts; for Cab Entry, Mounted Left
and Right, Each Side at "B" Pillar
MIRRORS (2) {Lang Mekra} Styled; Rectangular, 7.09" x 15.75" & Integral Convex Both Sides, 102"
Inside Spacing, Breakaway Type, Heated Heads Thermostatically Controlled, Power Both Sides,
Clearance Lights LED, Bright Finish Heads & Brackets
SEAT BELT All Red; 4 to 6
AIR CONDITIONER {Blend-Air} With Integral Heater & Defroster
CLAMPS, HEATER HOSE Mubea Constant Tension Clamps
HEATER HOSES Premium
REFRIGERANT Hydrofluorocarbon HFC-134A
CAB SOUND INSULATION Includes Dash Insulator and Engine Cover Insulator
INSTRUMENT PANEL Center Section, Flat Panel
FRESH AIR FILTER for HVAC
Revised February 28, 2011
Page 62 of 64
RAGE Pumper Demo #4000
Wildland Type III
STORAGE POCKET, DOOR Molded Plastic, Full Width; Mounted on Passenger Door
CAB INTERIOR TRIM Deluxe; for Crew Cab
"A" PILLAR COVER Molded Plastic
CAB INTERIOR TRIM PANELS Cloth Covered Molded Plastic, Full Height; All Exposed Interior
Sheet Metal is Covered Except for the Following: with a Two-Man Passenger Seat or with a Full
Bench Seat the Back Panel is Completely Void of Covering
CONSOLE, OVERHEAD Molded Plastic; With Dual Storage Pockets with Retainer Nets and CB
Radio Pocket
DOOR TRIM PANELS Molded Plastic; Driver and Passenger Doors
FLOOR COVERING Rubber, Black
HEADLINER Soft Padded Cloth
INSTRUMENT PANEL TRIM Molded Plastic with Black Center Section
STORAGE POCKET, DOOR (1) Molded Plastic, Full-Length; Driver Door
SUN VISOR (2) Padded Vinyl with Driver Side Toll Ticket Strap, Integral to Console
CAB REAR SUSPENSION Air Bag Type
WHEELS, FRONT DISC; 22.5" Polished Aluminum, 10-Stud (285.75MM BC) Hub Piloted, Flanged Nut,
Metric Mount, 8.25 DC Rims; With Steel Hubs
WHEEL SEALS, FRONT Oil Lubricated, Includes Wheel Bearings
WHEELS, REAR DUAL DISC; 22.5" Polished Aluminum, 10-Stud (285.75MM BC) Hub Piloted, Flanged
Nut, Metric Mount, 8.25 DC Rims; With Steel Hubs
WHEEL SEALS, REAR Oil Lubricated, Includes Wheel Bearings
BDY INTG, REMOTE POWER MODULE (2) Mounted Under Cab or On Battery Box; Up to 6 Outputs & 6
Inputs each, Max. 20 amp. per Channel, Max. 80 amp. Total per Power Module (Includes Switch Packs
With Latched Switches)
BDY INTG, POWER MODULE AUX (1) Mounted on the Driver's Side Frame Rail at Rear of Frame; Up to
6 Outputs & 6 Inputs, Max. 20 Amp. per Channel, Max. 80 Amp. Total
BDY INTG, I/O EXPANSION HARNES {for Diamond Logic Builder} In-Cab wire harness (DLB) program
only, Includes a harness with five blunt cut wires routed on lower left of instrument panel. Two ground
active inputs and two (.5Amp) relay drivers outputs are provided
BDY INTG, HEADLIGHTS, WIG WAG High Beam Wig Wag With Park Brake Interlock, Park Brake
Disables Wig Wag
Revised February 28, 2011
Page 63 of 64
RAGE Pumper Demo #4000
Wildland Type III
(2) TIRE, FRONT 12R22.5 G282 MSD (GOODYEAR) 481 rev/mile, load range H, 16 ply 68/0 68
(4) TIRE, REAR 12R22.5 G282 MSD (GOODYEAR) 481 rev/mile, load range H, 16 ply 0/136 136
Cab schematic 100GM
Location 1: 2637, Red (Custom)
Chassis schematic 936GM
Frame: 2637, Red (Custom)
Revised February 28, 2011
Page 64 of 64
Download