DR Layout Description ILC DR Technical Baseline Review Frascati, July 7, 2011 Mark Palmer Cornell University Introduction • Dave has provided an overview of the overall layout • This talk will focus on key elements of the present layout and the modifications from the previous baseline – Principally: • Straights and Alcove/Cavern Layout • Beam Line Spacing/Tunnel Diameter Issues – CFS Discussions included: • Rough Arc Estimate • Preliminary discussion of utilities specifications July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 2 Straights Layout • Layout Issues in Straights – Minimize length consistent with 3.2km design requirements – Maintain injection/extraction layout – Minimize phase adjustment trombone – Scale the circumference chicane with the size of the ring – Space in RF & wiggler sections for all design options (low & high power, 10Hz ops) – Added space in wiggler section for photon absorber July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 3 Interface with CFS • June 2, 2011 Meeting – Review shorter straights • RF-Wiggler Layout • Cavern/Alcove Requirements – Beam Line Spacing Presently set to 1.3m – Set tunnel diameter – Rough estimate of arcs July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 4 RF Longitudinal Picture RF Cavity Placement Positron Ring #2 Positron Ring #1 Date Event Global Design Effort 5 Wiggler Cell Date Event Global Design Effort 6 RF-Wiggler Straight RF-Wiggler Straight Elements (712.3m - 2 rings) 4 ElectronEle Element Values: |1| a Quadrupole |2| a Wiggler |3| a RF Cavity 3 PositronEle 2 Element Type 1 0 -1 -2 -3 -4 -375 -250 -125 0 125 250 375 Loca on (m) July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 7 Tunnel Diameter Issues Distributed PS Racks? 42cm dia 1.42 m 2.6 m Assumptions: 1) Remove large foot floor supports 2) Assume waveguides are rerouted 3) Reduce scale to 90% (~half of potential reduction with 500MHz a 650MHz cavities 4) 1+2 a 0.85 × height, 3 gives another factor of 0.9 5) NOTE: No cryostats are located directly above each other when longitudinal positions are accounted for 5.5 m dia 6.0 m dia ~0.9 m 2.09 m RF Alcove 2.09 m June 2, 2011 CFS Meeting Global Design Effort 8 Injection-Extraction Straight DTC01 Injec on-Extrac on Straight 6 ElectronEle PositronEle 4 Element Type 2 0 -2 Element Values: |1| a Quadrupole |2| a Extrac on Kicker |3| a Injec on Kicker |4| a Extrac on Septum |5| a Injec on Septum -4 -6 -400 -300 -200 -100 0 100 200 300 400 Loca on (m) July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 9 The Basic Racetrack July 7, 2011 ILC DR Technical Baseline Review Frascati, July 7-8, 2011 10