New OS32C-DM with Measurement Data

advertisement
New
OS32C-DM Safety
Laser Scanner with
Measurement Data
Confidential © Omron
1
New OS32C-DM with Measurement Data
• Uses standard EtherNet/IP communications (Not CIP)
• Can be monitored by ODVA Ethernet/IP compliant
products
◦ PLCs
◦ HMIs
◦ PCs
• System status, zone status, and measurement data can
all be monitored over EtherNet/IP
• EtherNet/IP is for monitoring only
Confidential © Omron
2
New OS32C-DM with Measurement Data
Confidential © Omron
3
Other OS32C Enhancements
• Configuration Tool version changes from 1.5.0 to
1.6.0 (Download from www.sti.com)
◦ Non-Safety Checksum
 Checksum value is updated when changes are made to the
warning zones or the non-safety-critical parameters
◦ Import/Export Zone Coordinates
 Allows for CAD drawing coordinates to be imported in the
zone configuration
◦ Maintenance Access Level (all scanners)
 Allows a user to modify non-safety parameters only
Confidential © Omron
4
Zone Coordinate Import/Export
Confidential © Omron
5
OS32C-DM Data
• Detection Zone State
◦ Can provide information about Warning 1, Warning 2, and
Safety zone status per beam
• Input & Output status
◦ Zone selection inputs (verification that inputs have
changed)
◦ Auxiliary and safety outputs
• Configuration checksum values
◦ Verification of settings from commissioned values
• Measurement data
◦ Provides distance in mm or time of flight in picoseconds or
reflectively (signal strength) information per beam
◦ Longer range than safety, up to 50m
Confidential © Omron
6
EDS File and Assemblies
• EDS File (Electronic Data Sheet)
◦ Tells the configuration software:
 How to find device info, ie version
 How to find and setup / configure the device
 Contains a list of assemblies and the data size
• Input Assembly Object examples
◦ Define what data is being communicated from the sensor to the PLC
 System status
 Zone Status
 Measurement data
 Range data
 Reflectivity data
• Output Assembly Object examples
◦ Beam report selection mask register
 Allows reporting on a subsection of beams
– Angle
– Individual Beam selection
Confidential © Omron
7
Network Configurator
EDS File
provides this
information
Confidential © Omron
8
Input Assembly: System Status Data
• Machine State
◦ Run, Stop, Interlock, etc
•
•
•
•
Machine Stop Reason
Active Zone Set
Zone input Status
Detection Zone Status
◦ Safety and Warning
• Output Status
◦ OSSDS, and Aux
• Input Status
◦ EDM, Start, Standby
Confidential © Omron
9
• Seven Segment Display
• Non-safety Checksum
• Safety Checksum
Understanding Measurement
• Safety - multiple scans = longer response time
• Measurement – single scan = 40ms response time fixed
• Reflectivity of object affects accuracy
D = (c x T)/2
c = 299,792,458,000 mm/sec
Distance to object determined by the “time of flight” of the light pulse.
Confidential © Omron
10
Distance Measurement Accuracy
Flat black 6%
•
Brown/grey
cardboard 20%
White paper
85%
Examples: white paper @ 1m, error=10mm, white paper @ 2m, error=20mm; brown
cardboard @ 1m, error =10mm, brown cardboard @ 2m, error=10mm)
Confidential © Omron
11
Application: Range Finding
• Intelligent Navigation
• Customer needed intelligent automated fork lifts to load pallets
onto trailer trucks
• The fork lifts need to track the sides and determine where the
next pallet will be placed.
• Multiple zone sets, up to 70
• Measurement Distance data
• Signal strength Data (positioning via reflector reference)
Confidential © Omron
12
Application: Reporting
• Large scale process line
• 30 plus scanners per assembly line.
• Customer needed a complete machine status update with a
simple request
• Customer needs to maximize machines efficiency and minimize
maintenance and down time.
• Ethernet I/P was the customers protocol of choice.
• Immediate machine status reports
• Configuration check sum to assure there was no tampering with
any scanner settings.
• Confirmation that the appropriate zone was active when the
machine controls requested it.
Confidential © Omron
13
User Integration tools
• Easy to use function blocks
◦ Perfect for simple PLC controlled status and data
updates.
◦ A simple effective method to integrate the status and
measurement data to a PLC.
◦ These function blocks can be used in the PLC code to
automatically configure the PLC to process and
display the information
Confidential © Omron
14
Omron PLC Function Block: Measurement Configuration
• Used to report the
range data for any
needed part of the
270 deg field
• Select any start
location and size of the
data to be reported
• Change report data on
the fly if needed
Confidential © Omron
15
Omron PLC Function Block: Measurement Configuration
Input Assembly: This is the start PLC
memory location of the input assembly,
this is entered as an DINT second word
should be 0
Output Assembly: This is the start
PLC memory location of the output
assembly, this is entered as an DINT
second word should be 0
Out Beam Data: This is the start PLC
memory location where the calculated
range data will be written too. The DM
location size will change with beam
angle & bean spread are changed.
Beam Angle size: This is the size of
the data that will be ouputted by FB,
this entered as deg from 2 deg to 268
deg.
Beam Start Loaction: Start location of
range data read. 2 to 270 deg
Beam Spread: Number of beams to be
used, 1,2,4,8,or 16
Confidential © Omron
16
Omron PLC Function Block: Measurement Configuration
• Beam Angle size
◦ the size of data that will be
output by FB, entered as deg
from 2 deg to 268 deg
• Start Beam Read angle
location
◦ set in deg’s. 2 -270 deg
location at where the scan angle
will start reading
• Beam Spread (resolution)
◦ Setting: 1,2,4,8 or 16
◦ Sets the number of beams
used: 1 = every beam, 2 = 2nd
beam, 4 = 4th beam
Confidential © Omron
17
90 deg
90
deg
Omron PLC Function Block: Measurement Configuration
• Function Block Output Information
◦ Can report the specified range data within the 270 deg. field of view.
◦ Select any start location and the size of the of the data to be reported.
◦ This also enable you to change this report data on the fly if needed.
Confidential © Omron
18
PC: User Integration Tools
• Visual Studio software downloadable from Microsoft
website
• Visual Studio software examples package on STI
website
◦ Perfect for large process PC controlled applications where
large amounts of data is required to determine product
quality, consistency or process variations
◦ Supports Visual Studio 2010 and 2012
◦ Examples written in C-code and portable to other C, C++
compilers.
◦ Developers can use to create desktop or embedded
applications
◦ EtherNet/IP Dynamic Link Library (DLL) for Microsoft
Visual Studio C++ and C# Applications
Confidential © Omron
19
Ordering Information
Item Number
Model Number Description
OS32C-BP-DM
40589-0013
OS32C-SP1-DM
40589-0023
OS32C-SN-DM
40651-0013
Confidential © Omron
20
OS32C LASER SCANNER WITH ETHERNET /IP,
MEASUREMENT DATA AND CABLE ACCESS FROM THE
BACK
OS32C LASER SCANNER WITH ETHERNET /IP,
MEASUREMENT DATA AND CABLE ACCESS FROM THE LEFT
SIDE
OS32C SPARE SENSOR WITHOUT I/O BLOCK
Competitors
Safety Measurement Connectivity Data Rate Transmission
Range
Type
(Max)
Distance
Range
OS32C-DM
Keyence SZ-16D
Sick S300 pro/cms
3m
50 m
4.2 m
16 m
2m
Sick S3000 pro/cms 4-7 m
21
No Limit
RS-422
250 kBaud
30 m
30 m
RS-422
115.2
kBaud
100 m
50 m
RS-422
500 kBaud
100 m
Note: 500 Kbaud ≈ 62 Kb/sec
Confidential © Omron
EtherNet/IP 100 Mb/sec
Questions
Confidential © Omron