280000S04_UKSecurityStandard

advertisement
UK
28000S04
Main Campus and UK Healthcare
Security System Standard
28000S04- ELECTRONIC SAFETY &
SECURITY-Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky A n E q u a l O p p o r t u n i t y U n i v e r s i t y
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
Table of Contents
PAGE
1.1
Summary
1.2 DSI, Security Unit Price Contractor
3
4
2.1
System Overview
2.2 System Description
5
5
3.1
UK Campus Security System
3.2 Network Architecture
3.3 Business Units Delegated Authority
3.4 Business Units Building Assignments
6
7
8
4.0
Project Deliverables
10
5.1
Products
5.2 Network Appliance: NLSS GW-4000
5.3 Access Card Technology
5.4 Keypads and Card Readers
5.5 Access Control Hardware
5.6 Long Range Card Reader
5.7 Door Hardware
5.8 Existing Door Key Locks
5.9 Emergency Notification Tower
5.10 Camera Pole
5.11 IP Interior Notification
5.12 Cameras
5.13 WIFI IP Enabled Access Control Locks
5.14 IP Power Over Ethernet Access Control Locks
12
13
13
13
14
14
14
15
15
16
16
17
17
17
6.0
Manufacturer’s Warranty
18
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
2
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
1.1
Summary
In response to increased security needs and trends across the Nation, during spring 2011 the
University of Kentucky Police Department, UKPD, determined that a campus wide unified security
system was needed. The proposed system would provide a video management system (VMS)
and security management system (SMS). The proposed system would provide situational
awareness to targeted areas on campus and utilize Video Event driven analytics to alert UKPD
of possible threats to campus. The proposed project would provide campus-wide camera
monitoring, early warning system speakers, and other communication devices to monitor and
respond to campus incidents. This centralized and campus-wide system would allow for large
occupancy structures or restricted areas to be outfitted with access control devices that will
restrict ingress remotely from a central location. The proposed new system would include a
single ID card. This New ID card utilizes the highly secure iClass technology, as well as other
technologies which would allow compatibility with many of the existing legacy systems.
At the same time an updated UK Veterinary Diagnostic Lab, VDL, was being constructed. This
lab had unique functions that are open to the public while maintaining highly restricted lab
diagnostic areas. The VDL project had a state of the art security system that allowed for
analytics and access control to be locally and centrally administered. A complete working
demonstration of this system was presented in November of 2011. This system included many
of the features that the UKPD required. A University Security Executive Team was responsible
for soliciting additional vendors. Five national SMS/VMS vendors presented to the Executive
Committee and UKIT. A Request for Proposal (RFP) inclusive of a Campus Security Master
Plan was prepared by Biagi, Chance, Cummins, London Titzer, Inc. The RFP included 15
Academic buildings based on their highest student occupancies. Those building are White
Hall, Chemistry-Physics, TH Morgan, WT Young Library, Funkhouser, Memorial Hall, Student
Center, Main Building, Patterson Office, Bio Pharmacy, Smith Hall, Ingles Hall, Baldwin Hall,
Roselle Hall and VDL.
Next Level Security Systems (NLSS) was selected as the manufacturer of the VMS/SMS security
platform. Dallmann Systems Incorporated was selected as the Security Integrator. DSI’s
proposal included a replacement of the UK Healthcare Video Management System (Occularis)
and Security Management System (Ccure). This replacement was in lieu of integration between
the new Security System and the existing Systems at UK Healthcare as required by the RFP.
The NLSS / Security Platform will allow UKPD the ability to correlate video surveillance,
analytic alerts and access control data into a single user interface that will enable the UKPD
to initiate a proactive response by automated alerts and responses to critical events.
Contact Tom Sorrell or Wayne Wilson of BCCLT, Inc. for additional technical information
concerning the campus system design. 502-633-1506. www.bcclt.com
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
3
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
1.2
DSI, Security Unit Price Contractor
In February 2013 DSI, Dallmann Systems Inc. of Jeffersonville, Indiana was issued a Work
Order to install a complete VMS/SMS platform campus wide. The contract included the issuance
of 40,000 iClass ID’s, 26 Exterior Talk-A-Phones and 21 Building Interior Notification installations.
In addition DSI was to provide the following additional services.
1.3
iClass ID Issuance
As of September 1, 2014 50,000 iClass ID’s will be issued. Please contact UKPD for
additional information.
1.4
UK Installations
A
B
C
D
E
F
Gateway Installations
Building Access Control
Building Interior Cameras
Building Interior Notification
Campus Cameras
Campus Emergency Phone / Emergency Notification
As of September 1, 2014 34 Gateways will be installed, 15 buildings have been provided
Access control, 25 buildings have Interior Cameras, 4 buildings have Interior Notification, 150
Campus Cameras and 26 Campus Emergency Phones. Please contact UKPD for additional
information.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
4
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
2.1
2.2
System Overview
1.
Video Management System (VMS) monitors areas on campus.
This VMS allows event-based monitoring of campus and situational awareness though IP
cameras centrally managed from the University of Kentucky Police Department. The VMS
utilizes analytics to identify potential situations on campus and preserving evidence for
authorities to review. The NLSS VMS has the capability to be securely monitored via
mobile devices or off-campus locations, video sharing with outside public safety first
responders
2.
Security Management System (SMS) to secure facilities on campus.
The VMS platform partners with the Security Management systems on campus to provide
UK Police with the ability to limit ingress to buildings but offering free egress from all
buildings, from its Communications center and immediately lock buildings when necessary.
3.
Standardized Campus ID.
A standardized campus ID allows the Police to integrate SMS with existing and new Access
Control systems on Campus.
4.
Early warning speakers to broadcast threats to campus safety.
In response to a crisis, the UK Police Department is able to provide immediate
notifications to alert persons on campus through a combination of warning speakers, voice
calls, emails, and text messages.
5.
Emergency Power. All Security System components will be on Emergency Power where
available and where not available a UPS will be provided to allow for twenty (20) minutes
of full backup on VMS Gateway and Access Control. Where Emergency Power is available
the Gateway unit shall be on UPS to protect unit during power transfers.
System Description
The NLSS system is an open standards-based, networked platform that integrates Video
Surveillance, Video Analytics and Access Control in a single platform.
The NLSS system allows for operation in a distributed model, and/or in conjunction with a
Centralized model.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
5
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
3.1
UK Campus Security System
3.2
Network Architecture
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
6
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
3.3
Business Units Delegated Authority
It is estimated that over 50,000 ID cards will be actively used on campus daily. Due to this large
number of participants, over 300 Lexington campus buildings in all operating within 700 acres of
campus, a “Delegated Authority” was essential in managing the proposed VMS/SMS application.
This “Delegated Authority” allows UKPD to be the owner of all components of the UK Main
Campus Security System. It also delegates privileges to all Business Units to manage and
authenticate. This approach allows the two PPD’s to have building access privileges to multiple
facilities to perform house keeping, operation and maintenance duties. This “Delegated Authority”
also maintains that only Facilities assigned to each Business Unit has Access privileges. To date
43 Business Units have been granted “Delegated Authority”.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
7
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
3.4
Business Units Building Assignments
The entire Lexington Main building inventory was assigned to each of the 44 Business Units.
The assignment was based on the principal occupant of the building. Any building that had
multiple Business Units with in the same building were assigned to UKPD. Further, any Business
Unit not willing to perform their administrative functions also were assigned to UKPD. The
assignments of buildings to individuals Business Units will be revised as buildings use and
occupants change.
UK Business Units
Building Numbers
College of Agriculture
0050,
0097,
0162,
0229,
College of Arts & Sciences
Carol Martin Gatton College of Business &
Economics
College
Studies
College
College
College
of Dentistry
of Design
of Education
College
College
College
College
College
College
College
College
College
of
of
of
of
of
of
of
of
of
0062,
0099,
0163,
0231,
0064,
0154,
0164,
0236,
0066, 0073, 0076, 0088, 0091, 0092, 0094,
0155, 0156, 0157, 0158, 0159, 0160,0161,
0177, 0182, 0183, 0184, 0185, 0236, 0215,
0275, 0276, 0282, 0287, 0312,
0002, 0024, 0028, 0044, 0051, 0053, 0056, 0057, 0058, 0059,
0061, 0065, 0078, 0082, 0090, 0216, 0225, 0343, 0344, 0345,
0346, 0347, 432, 618,
0034, 0047
of Communications and Information
Engineering
Fine Arts
Health Sciences
Law
Medicine
Nursing
Pharmacy
Public Health
Social Work
0042,
0297, 0489
0035, 0041,
0001, 0016,
0038,
0281,
0021,
200
0048,
0086,
0232,
596,
0003,
0043, 0045, 0046, 0052, 0070, 0107, 0108, 0209, 0237,
0286, 0495, 503, 633,
0022, 0101, 0102, 0207, 0210, 0241, 0402, 433, 482,
0400,
0298, 506, 509, 517, 9983,
Athletics
0019, 0074, 0110, 0113, 0117, 0212, 0213, 0222, 0272, 0277,
0283, 285, 413, 448, 449, 450, 451, 452, 453, 485, 585, 604,
644
Chandler Hospital
0087, 0093, 0096, 0098, 0293, 0294, 602, 630,
Good Samaritan
0010, 611, 8633,
Kentucky Children's Hospital
Shriners Hospital
UK Clinic
0223, 0284, 0582
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
8
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
DLAR
Research Facilities / RAD Services / Grant
Restricted
0305,
EHS
0214, 0314, 490,
Libraries
0224, 0456,
Student Affairs / Student Center / Rec Facilities
0030, 0031, 0049, 0219, 0220, 0227, 494, 504, 505, 592, 616,
0067, 0068, 0069, 0077, 0118, 0121, 0122, 0124, 0125, 0126,
0127, 0128, 0129, 0137, 0138, 0140, 0142, 0507,
Fraternities and Sororities
Food Service
Med Center PPD
0057, 0230,
Main Campus PPD
CNS
0012,0014, 0071, 0081, 0147,
0075, 0085, 0089, 0278, 612,
0004, 0005, 0103, 0204, 0279, 0288, 0289, 0300, 0302, 514,
518,
0269,
Parking
0166, 0167, 0170, 0173, 0175, 0176, 0178, 0187, 0197, 0198,
0199, 0200, 390,391, 392, 393, 394, 397, 398, 399, 416, 418,
419, 571, 572, 601, 613,
Housing
EDR
0006, 0007, 0008, 0009, 0011, 0012, 0072, 0105, 0106, 0110,
0130, 0131, 0132, 0135, 0136, 0143, 0144, 0145, 0146, 0148,
0149, 0150, 0151, 0152, 0153, 0188, 0190, 565, 566, 567, 568,
243, 244, 245, 246, 0247, 0248, 0249, 250, 251, 252, 253,254,
255, 256, 257, 258, 259, 260, 261, 262, 263, 264, 265, 266, 267,
268, 0240, 0191, 0192, 0193, 0194,
0079, 0080,
UKPD
Graduate School
KCTCS/BCTC
Maxwell Place
CAER
0023, 0025, 0026, 0027, 0015, 0029, 0032, 0033, 0036, 0037,
0040, 0054, 0083 , 0119, 0211, 0301, 0315, 0324, 0325, 0327,
0333, 0336, 0337, 0348, 0349, 0351, 353, 355, 607, 608, 461,
442, 420, 356, 361, 362, 363, 365, 377, 378, 381, 386, 401, 412,
417, 8, 460, 461, 467, 473, 484 , 487,488, 564, 600, 605, 607,
608, 609, 610, 614, 615, 617,
619, 621, 622, 623, 624, 625, 626, 631, 636, 637, 639, 641, 646,
647, 648, 649, 9127,
0235, 0274, 0481,
40, 211
3382 (Spindle Top Research Park)
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
9
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
4.0
Project Deliverables
A Capital Construction project typically exceeds $600,000.00 in Total Scope of Work. However,
as shown in the Security Systems Procurement Drawing ALL contract types are available to
CPMD PM’s to use and implement security installations. This alternative method includes Job
Orders to UKPPD or UK Key Shop, Purchasing Solicitations, Price Contracts, CPMD Bidding
and Security Unit Price Contract.
TYPICAL METHOD:
It is envisioned that all CPMD projects in excess of $600,000 will obtain their Security
components from a designer contracting and advertising for a Security Integrator. The Security
Integrator will typically be a sub-contractor to the electrical contractor. Under this Method following
the Security Integrator’s installation and commissioning, DSI, the current Security Unit Price
Contractor, would verify and connect the new installation on the campus Security Platform.
ALTERNATIVE METHOD:
1.) DSI could also perform other steps in implementing the security design.
2.) DSI could provide an assignable allowance to design and install the security components.
This proposed method is similar to the Simplex Fire Alarm allowance.
Both of these Alternative Methods may not produce the most competitive pricing.
RENOVATIONS:
If the design contract is primarily renovation of an existing facility, a security assessment may
be necessary. Today this assessment is being provided by BCCLT, Inc. Shelbyville, KY, 502633-1506.
The assessment provides a detail Security Scope of Work and an Estimate without incurring
significant design expense.
The assessment and estimate can typically be provided within 30 days following the issuance of
a Work Order to DSI, Security Unit Price Contractor.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
10
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
11
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.1 Products
Unit Price Contract Components
Refer to Appendix A
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
12
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.2
Network Appliance: NLSS GW-4000-UK
Each building fitted with Access Control and or Cameras MUST have at a MINIMUM One
(1) NLSS GW4000-UK Gateway installed. The number of Gateways will be determined by
the quantities of Cameras and Access Control Points.
a.
The Gateway is a standards-based, networked platform based on Linux Ubuntu, MySQL,
Apache, PHP and Flash.
b.
The Gateway supports an easy-to-use, intuitive, Web-browser interface to the system.
c.
The Gateway natively supports the security levels as established by the University.
d.
The Gateway supports multiple simultaneous users on the system.
Appliance Hardware
5.3
5.4
a.
The Gateway has two (2) 1 GB Ethernet ports, one supports private connection to cameras
the other normal network connectivity.
b.
The Gateway has four (4) or more USB 2.0 or above ports.
c.
The Gateway has an internal Hard Disk Drive (HDD) capacity of Eight (8) TB (Terabytes).
Access Card Technology
a.
The system supports the following access card bit formats:
1.
HID Corporate 1000 - (University of Kentucky format)
2.
The system shall support user-definable custom card bit formats.
b.
The system requires HID iCLASS 13.56 MHz credentials and readers.
c.
The system supports legacy 125 kHz Proximity credentials and readers.
Keypads and Card Readers
a. The system supports the use of keypads and iClass and Prox Card readers on, Assa Abloy
wireless and POE models and Mercury controllers.
b.
The system supports the configuration of single door card-in/card-out readers on Mercury
EP1501 controllers.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
13
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.5
Access Control Hardware
a.
The Gateway supports the following third party access controllers and readers:
1.
2.
3.
4.
5.
6.
7.
5.6
Mercury Security EP1501
Mercury Security EP1502
HID Edge ERP40 Reader/Controllers
HID Edge+ E400 Controllers
HID bioCLASS Biometric Keypad Smart Card Reader
Sargent vS1 PoE locks
Sargent vS2 Wireless locks
b.
The Gateway supports the following third party AC Reader Interfaces:
1. Mercury Security MR52
2. Mercury Security MR50
3. Mercury Security MR51e
c.
The Gateway supports the following, but not limited to, third party access hardware I/O
modules:
1. Mercury Security MR16in
2. Mercury Security MR16out
d.
The Gateway supports the following third party Power over Ethernet
(PoE) devices mentioned below:
1. Mercury Security EP1501
2. Mercury Security MR51e
3. HID 6120 (R40) Readers
4. Sargent v.S1 locks
e.
The Gateway supports the following third party card readers:
1. HID Prox
2. HID multiCLASS
3. HID iCLASS
Long Range Card Reader:
Long Range Card readers must be used at all ADA entry doors on all buildings.
Refer to UK Standards – ADA.
Long Range Reader Shall be:
1. HID’s iCLASS® Long Range Reader
2. HID Model 6150 (R90)
5.7
Door Hardware
Refer to UK Standard – Division 8 Windows and Doors for applicable installations.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
14
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.8
Existing Door Key Locks
When Access Control is added to existing campus buildings any door with key locking Capability
shall have Door Monitoring installed. After door position monitoring or access control is added
all key cores will be removed. Key cores will remain at ADA doors only as the Emergency
Access point on all buildings with SMS. Keys will no longer allow access to the building unmonitored.
5.9
Emergency Notification Tower
Talk-A-Phone Model: WEBS-MT/R OP 4
Including:
VOIP-500 IP Phone
WEBS-BACKUP 24hr backup power
WEBS-CONTACT WEBS Contact MNS Software Paging & Diagnostics Package
WEBS-PA-2IP IP Outdoor Area Paging Unit
General Description
The unit is highly vandal-resistant free-standing steel emergency phone tower mount, with
built-in combination LED Blue Light, illuminated faceplate, an integrated extension arm for
mounting a CCTV dome camera and Emergency Notification System (ENS) capability. The
tower houses an ADA-compliant, communication device. The Tower runs daily self- diagnostics,
testing lights, phone, amps and UPS units and send reports to administration.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
15
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.10
Camera Pole
SUMMARY
Exterior cameras are mounted on top of decorative free-standing
accommodating a variety of different manufacturers’ network cameras.
aluminum
pole
PRODUCT
Campus camera poles are a 14 foot Holophane Charlestown CH14F4 Black aluminum fluted
pole or equal on central campus. South campus is a Moog VideoLarm P1800 or equal. Refer
to UK Specification section 16530S01 - SITE LIGHTING for more information. Specification
can be found at this URL:
http://www.uky.edu/EVPFA/Facilities/CPMD/standards/div16/16530s01_Site_Lighting.pdf
South campus area is defined as the area South of Woodland Ave., Hilltop Ave. and University
Drive to Huguelet Ave over to Rose Street. The Dorm Complex, Central / Haggin Hall, Med
Center, Ag Buildings and all parcels south of these buildings are included in this area. All other
areas are considered central campus. Pole base must match the bases of existing poles in the
area of installation.
Poles must be installed to match the pattern of the existing pole in the area of installation.
5.11
IP Interior Notification
Currently Interior Notification consists of utilizing InformaCast broadcasting thru Simplex Fire
Alarm Panel 4100 or compatible voice evacuation system. All installations will be in accordance
with the most current NFPA standards.
Valcom IP Horn Model: VIP-480L-IC with V-9805 Vandal-Resistant Enclosure
The IP Paging Horn is a self contained paging system which enables voice paging up to 1200
feet from an Ethernet connection. The Horn consists of a high efficiency 3 Watt Class-D Horn
and a VOIP unit allowing it to be accessed from a variety of managed VoIP products. The Horn
has a distance limit of 300 feet with connection to PoE switch, up to 1200 feet with use of an
extender unit.
The Horn supports InformaCast - IP Notification by Singlewire Software. It is Cisco compliant.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
16
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
5.12
Cameras
Exterior: Sony SNC-ER580 (PTZ) with Sony UNI-ORL7C2/T2 Series (Dome Enclosure),
Sony SNC-CH210 with Moog FDP75C2N Enclosure or AXIS P3346-VE .
Interior: Sony SNC-VM601B or Samsung SNV-7084.
General Requirements
5.13
a.
The camera must be of the manufacturer’s official product line, designed for commercial
/ industrial 24/7/365 use.
b.
The camera is based upon standard components and proven technology using open
and published protocols.
WIFI IP Enabled Access Control Locks:
(MAY ONLY BE USED ON INTERIOR DOORS)
IP Enabled IEEE 802.11 b/g (2.4 GHz) WiFi Access Control Integrated Card Reader Lock,
BHMA certified extra heavy duty, lever type lock. Lockset with integrated ® 13.56 MHz
contactless card reader, request-to-exit, latchbolt and deadbolt monitoring, and door position
signaling in one complete unit. Emergency override access capability with optional mechanical
key cylinder retraction of lock latch bolt without necessary electronic activation.
Models: (Or Equal) Equal MUST READ ALL iClass Information
SARGENT Manufacturing (SA) – Profile – S2 8200 Series.
SARGENT Manufacturing (SA) - N-120 Series.
5.14
IP Power Over Ethernet Access Control Locks
(MAY ONLY BE USED ON INTERIOR DOORS)
IP Enabled IEEE 802.3af Power-over-Ethernet (PoE) Access Control Integrated Card Reader
Lock, BHMA certified extra heavy duty, lever type lock. Lockset with integrated HID® 13.56
MHz contactless card reader, request-to-exit, latchbolt and deadbolt monitoring, and door position
signaling in one complete unit.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
17
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
Power Over Ethernet intelligent and integrated access control locking devices interface using
IEEE 802.3af Ethernet data and power communication capability directly from the locking unit
back to a host server over an existing or newly installed TCP/IP network.
Emergency override access capability with optional mechanical key cylinder retraction of lock
latch bolt without necessary electronic activation.
Models: (Or Equal) Equal MUST READ ALL iClass Information
Sargent Manufacturing (SA) – Profile – S1 8200 Series.
6.1
Manufacturer’s Warranty
a.
Product Warranty Period: One year commencing on Date of Substantial Completion.
b.
Z
c.
E
d.
Manufacturer’s Warranty: Submit, for Owner’s acceptance, manufacturer’s standard
warranty document.
e.
RFP Warranty: Five year commencing with the date of contract execution.
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky
18
28000S04- ELECTRONIC SAFETY & SECURITY
Main Campus and UK Healthcare Security System Standard (BCCLT, Inc.)
Appendix A
DSI Unit Prices
28000S04- ELECTRONIC SAFETY & SECURITY -Security System Standard
Dated: 12/2015
Applies to: All Projects
University of Kentucky