PumpStation5 Documentation Reference / Version Integrated Architecture Builder PumpStation5 Project Documentation Reference Version Monday, May 07, 2012 - 13:52 / Author 1 PumpStation5 Documentation Reference / Version Table of Contents: 1 Overview of Project 'PumpStation5' ........................................................................ 4 1.1 IAB Software Information: ............................................................................... 4 1.2 Integrated Architecture.................................................................................... 5 1.3 ControlLogix ................................................................................................... 7 1.4 In-Cabinet Modular Distributed I/O ................................................................... 9 1.5 Project's System List...................................................................................... 12 1.6 Project Errors/Warnings ................................................................................. 12 1.7 Project's Network list ..................................................................................... 12 1.8 Project's hardware platforms list ..................................................................... 12 1.9 Architecture View .......................................................................................... 12 2 Bill of Materials ................................................................................................... 12 2.1 Consolidated BOM ......................................................................................... 13 2.2 Positional BOM .............................................................................................. 14 2.3 Organized BOM ............................................................................................. 16 3 Network Details .................................................................................................. 19 3.1 Network 'ControlNet001' ................................................................................ 19 3.1.1 Graphics: .............................................................................................................. 19 3.1.2 Performance Data: ................................................................................................. 20 3.1.3 Layout Information: ............................................................................................... 20 3.2 Network 'ProfiBus001'.................................................................................... 21 3.2.1 Graphics: .............................................................................................................. 21 3.2.2 Performance Data: ................................................................................................. 21 3.2.3 Layout Information: ............................................................................................... 21 4 Hardware Platforms ............................................................................................ 23 4.1 Platform 'CLX_SS.1_CLogix001' ...................................................................... 23 4.1.1 Graphics: .............................................................................................................. 23 4.1.2 Performance Data: ................................................................................................. 23 4.1.3 Layout Information: ............................................................................................... 23 4.1.4 Cable Report for OnMach002 .................................................................................. 24 4.1.4.1 OnMach002: ..................................................................................... 24 4.1.5 Cable Report for OnMach003 .................................................................................. 25 4.1.5.1 OnMach003: ..................................................................................... 25 4.1.6 Cable Report for OnMach004 .................................................................................. 26 4.1.6.1 OnMach004: ..................................................................................... 26 4.1.7 Cable Report for OnMach005 .................................................................................. 27 4.1.7.1 OnMach005: ..................................................................................... 27 2 PumpStation5 Documentation Reference / Version 4.2 Platform 'CLX_SS.1.DIO_SS.1_FLX001'............................................................ 29 4.2.1 Graphics: .............................................................................................................. 29 4.2.2 Performance Data: ................................................................................................. 29 4.2.3 Layout Information: ............................................................................................... 29 5 Appendix: .......................................................................................................... 30 3 PumpStation5 Documentation Reference / Version 1 Overview of Project 'PumpStation5' 1.1 IAB Software Information: Integrated Architecture Builder software is a tool designed to assist you in defining an automation configuration. While Integrated Architecture Builder Software has been designed and tested for accuracy and Bill of Material completeness, the underlying variables and assumptions of the tool may cause actual results to vary from expected results. Users of Integrated Architecture Builder software must independently determine to their own satisfaction the applicability of the resulting configuration and must assume responsibility for the use of the resulting configuration and bill of material. Integrated Architecture Builder software provides informational data on expected performance results. Rockwell Automation is not liable for the correctness of this data. Processor Checks: The Processor Chassis Checkers check the processor and any associated I/O and devices. The checker examines power consumption of all chassis, estimates memory requirements for the processor(s), and counts connections for the Processor and any local communication modules necessary to handle the network bandwidth. Any device that is "owned" by this processor will be accounted for when performing the check. ControlNet Network Checks: The ControlNet Wizard checks the device connections, network cabling components, and additional performance information about the network. Given certain information about device connectivity to processors and basic network setup information, the ControlNet wizard will check details on scheduled and unscheduled bandwidth, propagation delay, and Network Update Time. Results are based on approximate DeviceNet Network Checks: The DeviceNet Wizard checks the device connections and network cabling (trunk, taps and drops). It also verifies correct network sizing (power consumption, maximum length and Baud rate). EtherNet Network Checks: The EtherNet Wizard checks the device connections, network cabling components, and additional performance information about the network. Given certain information about device connectivity to processors and basic network setup information, the EtherNet wizard will check details on CIP / TCP connections, I/O packets per second, and HMI packets per seconds. 4 PumpStation5 Documentation Reference / Version 1.2 Integrated Architecture The Convergence of Control and Information for Plantwide Optimization The Rockwell Automation Integrated Architecture™ system helps you to build a business in which information flows across your organization so you can better address key market challenges: Productivity Improve PRODUCTIVITY with better asset utilization and system performance. o Develop a standard set of engineering objects you can use across all of your applications o Merge the production floor with the enterprise system to improve data flow and make faster, more informed business decisions o Improve uptime, increase speed and simplify integration using intelligent devices o Take advantage of a single network infrastructure Innovation Cultivate INNOVATION with increased system flexibility and technical risk mitigation. o Invest less time in development so that you can spend more time creating new intellectual property o Quickly make production changes to better meet market demands o Mix industrial, business and commercial technologies to solve business challenges in new ways o Share best practices Globalization Promote GLOBALIZATION with easy access to actionable, plantwide information. o Easily extract, share and use information across your enterprise and around the world directly from manufacturing assets like your controllers o Track your manufacturing assets on a global basis o Take advantage of a single, global standard Sustainability Support SUSTAINABILITY with extended product lifecycles and better asset utilization. o Reduce waste by specifying a system in a footprint that meets your needs o Reduce energy costs by eliminating the need to "over-design" o Streamline required assets and simultaneously reduce storage, energy costs, and waste materials 5 PumpStation5 Documentation Reference / Version How does the Integrated Architecture system accomplish this? By leveraging exceptional, industry-leading features that include: Multiple Disciplines — Functionality for a full range of automation applications with common equipment and standards Scalable Dimensions — Offerings that are right-sized by product, architecture and core multiple discipline functionality EtherNet/IP — A single network of IT-friendly Ethernet for information, I/O and motion Real-Time Information — Live data and open access throughout your power and control system, enterprise and supply chain Knowledge Integration — Premier integration of device and system to maximize and secure your intellectual property The Integrated Architecture system provides the foundation to drive plantwide optimization efficiently and effectively, helping companies to respond competitively to the economy and changes in consumer demand. 6 PumpStation5 Documentation Reference / Version 1.3 ControlLogix For manufacturers, OEMs and Systems Integrators in virtually every industry, the Logix Control Platform increases productivity while reducing total cost of ownership. Unlike conventional architectures, the Logix Control Platform provides fully integrated, scalable solutions for the full range of automation disciplines including discrete, motion, process control, batch, drive systems and safety using a single control platform, a single development environment and using a single, open communication protocol. The platform enables you to reuse engineering designs and practices to reduce development time and cost, respond more quickly to customer or market demands, reduce maintenance costs and downtime and easily gain access to actionable plant and production information for improved management and decisionmaking. ControlLogix Programmable Automation Controller The Most Powerful, Most Expandable Controller ControlLogix brings together the benefits of the Logix platform—common programming environment, common networks, common control engine—to provide you with the performance your application requires in an easy-to-use environment. As part of the Logix Control Platform, you receive tight integration between the programming software, controller and I/O to reduce development time and cost at commissioning and during normal operation. Mix multiple controllers, networks and I/O without restrictions to address all disciplines Mix standard and safety control in same chassis The ControlLogix programmable automation controller (PAC) features a modular control platform with virtually infinite expansion of controllers, networks and I/O. With memory options up to 32MB, ControlLogix controllers support intensive process applications and provide fast processing of motion instructions in a single integrated solution. ControlLogix provides modular network communications that let you purchase only what you need. Interface using ControlLogix communication modules via a ControlLogix gateway without the need for a processor in the gateway chassis, or interface directly to a ControlLogix processor. You may also combine any number of EtherNet/IP, ControlNet, DeviceNet, HART, FOUNDATION fieldbus, or other networks for maximum communications flexibility. Or, you may route and bridge between CIP (Common Industrial Protocol) networks with no controller overhead. 7 PumpStation5 Documentation Reference / Version ControlLogix controllers also support redundant architectures with no additional programming or customized controllers for high availability. The primary controller automatically updates the secondary with any data changes needed to keep it synchronized. Additionally, standard ControlLogix products are certified by TUV for use in Safety Integrity Level (SIL) 1 and SIL 2 applications. By using the same platform and development software as standard control systems, you may reduce development costs. In terms of I/O, the ControlLogix platform provides a full range of digital, diagnostic digital, analog, motion control, and specialty I/O to meet a variety of application needs. Use any of the I/O modules in the local chassis of a ControlLogix controller or in a chassis linked to a ControlLogix controller across ControlNet™ or EtherNet/IP™ networks. Development Environment Streamline engineering with outstanding ease-of-use With RSLogix 5000, only one software package is needed for discrete, process, batch, motion, safety and drive-based applications. RSLogix 5000 offers an easy-to-use, IEC61131-3 compliant interface, symbolic programming with structures and arrays and a comprehensive instruction set that serves many types of applications. It provides ladder logic, structured text, function block diagram and sequential function chart editors for program development as well as support for the S88 equipment phase state model for batch and machine control applications. RSLogix 5000 can help: • reduce programming and ease startup and commissioning • ease diagnostics and troubleshooting • increase overall plant productivity 8 PumpStation5 Documentation Reference / Version 1.4 In-Cabinet Modular Distributed I/O In-Cabinet (IP20) distributed I/O can be placed throughout your application and requires an enclosure. Our In-Cabinet Modular I/O products let you select the exact mix of I/O interfaces and communication adapters to fit your needs, providing greater flexibility in designing your system. In addition to a wide range of analog, digital, and specialty modules, we provide in-cabinet I/O options for extreme environments, I/O for safety systems, and intrinsic safety (IS) I/O that can be distributed throughout hazardous areas. 1734 POINT I/O Bulletin 1734 POINT I/O™ is ideal for applications requiring flexibility and low cost of ownership. Granularity of one to eight points lets you buy only the I/O you need. The compact design makes installation easier in limited panel space. The family includes POINT Guard I/O™ safety-rated I/O modules that can be used side-by-side in a standard POINT I/O system. Network connectivity includes ControlNet™, DeviceNet™, EtherNet/IP™, and other open networks. Some modules feature DeviceLogix™ Smart Component Technology, integrating low-cost logic solving capability in your I/O for faster sense-to-actuation times. Features Modular design lets you independently select the I/O, termination style and network interface Components install easily by sliding together; pull apart easily for maintenance Removable wiring system saves time and money during installation and troubleshooting Comprehensive diagnostics and configurable features makes POINT I/O™ easy to apply Removal and Insertion Under Power (RIUP) lets you replace modules while the system is in operation Mount horizontally or vertically, with no de-rating required Auto Device Replacement (ADR) lets OEMs add features and I/O with minimal effort Add-On-Profiles in RSLogix 5000 programming software provide smooth integration into Integrated Architecture systems 1794 FLEX I/O FLEX™ I/O offers the functionality of larger rack-based I/O without the space requirements. FLEX I/O offers cost-effectiveness, flexibility, modularity, and reliability. Communication options include 9 PumpStation5 Documentation Reference / Version EtherNet/IP™, ControlNet™, DeviceNet™, Universal Remote I/O, and other networks. FLEX-I/O XT™ modules provide a distributed I/O solution for your ControlLogix-XT™ extreme environment system. Features Modular design lets you independently select the I/O, termination style and network interface Assembles without tools—all components snap onto a DIN rail and plug together to form the I/O system Mounts horizontally or vertically on a standard DIN rail Communicates on EtherNet/IP™, ControlNet™, DeviceNet™, Universal Remote I/O, and other networks Removal and Insertion Under Power (RIUP) lets you replace modules and make connections while the system is in operation FLEX-I/O XT™ extreme environment modules operate in a broader temperature range and are ANSI/ISA2, IEC and EMC-compliant Configuration wizards speed engineering and installation 1797 FLEX Ex I/O Bulletin 1797 FLEX Ex™ Intrinsic Safety (IS) I/O couples the benefits of our FLEX™ I/O platform with IS technology. This lets you distribute I/O throughout hazardous areas with a single or redundant fiber or coax cable, virtually eliminating standalone IS barriers and isolators, enclosures, long wiring runs, and cable trays. FLEX Ex I/O communicates with your control system over a ControlNet™ network. It is compatible with standard FLEX I/O and communication modules for added flexibility in network choices and system configuration. 10 PumpStation5 Documentation Reference / Version Features 11 Installs into hazardous areas (Zone 1) without purged or explosion-proof enclosures Provides a ControlNet-based solution in the hazardous area using ControlNet™ Ex products Modular design lets you independently select the I/O, termination style and network interface Assembles without tools—all components snap onto a DIN rail and plug together to form the I/O system Mounts horizontally or vertically on a standard DIN rail Removal and Insertion Under Power (RIUP) lets you replace modules and make connections in the hazardous area while the system is in operation Simplified engineering drawings, documentation, and site certification speed commissioning PumpStation5 Documentation Reference / Version 1.5 Project's System List This Project contains the following Systems: System: New System Subsystem: CLX_SS.1 1.6 Project Errors/Warnings With IAB implemented rules, project general status is OK. 1.7 Project's Network list Network Type ControlNet ProfiBus This Project contains the following networks: Network Name ControlNet001 ProfiBus001 Network Status Ok 1.8 Project's hardware platforms list This Project contains the following Hardware platforms: HW Platform Type HW Platform Name ControlLogix CLX_SS.1_CLogix001 Flex CLX_SS.1.DIO_SS.1_FLX001 1.9 Architecture View 2 Bill of Materials 12 PumpStation5 Documentation Reference / Version 2.1 Consolidated BOM System Status : Qty Catalog # Description 1 1756-A10 1756 Chassis 10 slots 1 1756-PA72 85-265 VAC Power Supply (5V @ 10 Amp) 1 1756-L71 Logix5671 Processor With 2 Mbytes Memory 1 1756-EN2T EtherNet 10-100M Bridge Module MVI561 PDPMV1 PROFIBUS Master V1 Communication Module 1 1756-CN2 ControlNet Interface Module 1 1756-IF16 Analog Input - Current/Voltage 16 Pts (36 Pin) 1 1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input 1492Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20 Conductors, #22 1 ACABLE025UA AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin D-shell Connector 1 1794-ACN15 Single Media Adapter For ControlNet 17941 IB16XOB16P 24V DC Combo Module, 16 Input, 16 Output 1 1794-TB32 32-channel screw terminal base (32 I/O; 8 common; 8 +V ) 1 1786-RG6 RG-6 Quad Shield Coax Cable (1.0m total reqd.) 2 1756-IB32 10-31 VDC Input 32 Pts (36 Pin) 2 1756-TBCH 36 Pin Screw Clamp Block With Standard Housing 2 1786-XT ControlNet BNC Terminator 2 1786-TPS ControlNet Straight T-Tap 3 1492-IFM40F 40-Point Feed-Through Digital IFM, Standard 1492Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH 3 CABLE025Z connector & IFM 40-pin connector 3 1756-OV32E 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin) Unit Price Price 596.91 596.91 884.76 884.76 5250 5250 2787.6 2787.6 N/A N/A 2110.9 2110.9 1504.9 1504.9 140.39 140.39 313.1 727.2 313.1 727.2 601.96 196.95 653.47 461.57 81.81 9.64 117.16 131.3 601.96 196.95 653.47 923.14 163.62 19.28 234.32 393.9 295.93 656.5 887.79 1969.5 Total: 20359.69 13 PumpStation5 Documentation Reference / Version 2.2 Positional BOM System Status : Pos/Slot Catalog # Description Networks Unit Price Price ControlNet001 : Segment_1 N/A 1786-RG6 0 1786-XT RG-6 Quad Shield Coax Cable (1.00 m reqd.) ControlNet BNC Terminator 0 1756-CN2 0 1786-TPS (CLX_SS.1_CLogix001) ControlNet Interface Module ControlNet Straight T-Tap 1 1794-ACN15 1 1786-TPS 1 1786-XT (CLX_SS.1.DIO_SS.1_FLX001) Single Media Adapter For ControlNet ControlNet Straight T-Tap ControlNet BNC Terminator Included in Included in Bulk Cable Bulk Cable Section Section 9.64 9.64 Included in Included in Hardware Hardware Section Section 117.16 117.16 Included in Included in Hardware Hardware Section Section 117.16 117.16 9.64 9.64 Subtotal: 253.6 ProfiBus001 MVI561 PDPMV1 (CLX_SS.1_CLogix001) PROFIBUS Master V1 Communication Module Included in Hardware Section Subtotal: Included in Hardware Section 0 Hardware CLX_SS.1_CLogix001 N/A N/A 1756-A10 1756-PA72 0 1756-L71 1 1756-EN2T MVI562 PDPMV1 3 1756-CN2 4 1756-IF16 1756 Chassis 10 slots 85-265 VAC Power Supply (5V @ 10 Amp) Logix5671 Processor With 2 Mbytes Memory EtherNet 10-100M Bridge Module PROFIBUS Master V1 Communication Module ControlNet Interface Module Analog Input - Current/Voltage 16 Pts (36 Pin) On-Machine BOM (OnMach002) 1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20 1492Conductors, #22 AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin DACABLE025UA shell Connector 5 1756-IB32 10-31 VDC Input 32 Pts (36 Pin) On-Machine BOM (OnMach003) 1492-IFM40F 1492CABLE025Z 6 1756-OV32E 1492-IFM40F 40-Point Feed-Through Digital IFM, Standard Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH connector & IFM 40-pin connector 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin) On-Machine BOM (OnMach004) 40-Point Feed-Through Digital IFM, Standard 14 596.91 884.76 5250 2787.6 N/A 596.91 884.76 5250 2787.6 N/A 2110.9 1504.9 2110.9 1504.9 140.39 140.39 313.1 461.57 313.1 461.57 131.3 131.3 295.93 656.5 295.93 656.5 131.3 131.3 PumpStation5 Documentation Reference / Version 1492CABLE025Z 7 1756-OV32E Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH connector & IFM 40-pin connector 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin) On-Machine BOM (OnMach005) 1492-IFM40F 1492CABLE025Z 8 1756-IB32 1756-TBCH 9 1756-OV32E 1756-TBCH 40-Point Feed-Through Digital IFM, Standard Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH connector & IFM 40-pin connector 10-31 VDC Input 32 Pts (36 Pin) 36 Pin Screw Clamp Block With Standard Housing 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin) 36 Pin Screw Clamp Block With Standard Housing 295.93 656.5 295.93 656.5 131.3 131.3 295.93 461.57 81.81 656.5 81.81 Subtotal: 295.93 461.57 81.81 656.5 81.81 17926.51 727.2 727.2 601.96 196.95 Subtotal: 601.96 196.95 1526.11 653.47 Subtotal: 653.47 653.47 CLX_SS.1.DIO_SS.1_FLX001 0 1794-ACN15 17941 IB16XOB16P 1794-TB32 Single Media Adapter For ControlNet 24V DC Combo Module, 16 Input, 16 Output 32-channel screw terminal base (32 I/O; 8 common; 8 +V ) Consolidated Network Spool Cables N/A 1786-RG6 RG-6 Quad Shield Coax Cable (1.0m total reqd.) Total: The pricing provided is List Price. Please consult your local sales person to get your specific pricing. 15 20359.69 PumpStation5 Documentation Reference / Version 2.3 Organized BOM System Status : Qty Catalog # Description Networks Unit Price Price ControlNet001 : Segment_1 1 1756-CN2 (CLX_SS.1_CLogix001) ControlNet Interface Module 1 1786-RG6 2 1786-TPS 2 1786-XT RG-6 Quad Shield Coax Cable (1.00 m reqd.) ControlNet Straight T-Tap ControlNet BNC Terminator 1 1794-ACN15 (CLX_SS.1.DIO_SS.1_FLX001) Single Media Adapter For ControlNet Included in Included in Hardware Hardware Section Section Included in Included in Bulk Cable Bulk Cable Section Section 117.16 234.32 9.64 19.28 Included in Included in Hardware Hardware Section Section Subtotal: 253.6 ProfiBus001 MVI561 PDPMV1 (CLX_SS.1_CLogix001) PROFIBUS Master V1 Communication Module Included in Hardware Section Subtotal: Included in Hardware Section 0 Hardware CLX_SS.1_CLogix001 Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20 1492Conductors, #22 AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin D1 ACABLE025UA shell Connector 313.1 313.1 1 1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input 140.39 140.39 1492Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/17563 CABLE025Z TBCH connector & IFM 40-pin connector 295.93 887.79 3 1492-IFM40F 40-Point Feed-Through Digital IFM, Standard 131.3 393.9 1 1756-A10 1756 Chassis 10 slots 596.91 596.91 1 1756-CN2 ControlNet Interface Module 2110.9 2110.9 1 1756-EN2T EtherNet 10-100M Bridge Module 2787.6 2787.6 2 1756-IB32 10-31 VDC Input 32 Pts (36 Pin) 461.57 923.14 1 1756-IF16 Analog Input - Current/Voltage 16 Pts (36 Pin) 1504.9 1504.9 1 1756-L71 Logix5671 Processor With 2 Mbytes Memory 5250 5250 3 1756-OV32E 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin) 656.5 1969.5 1 1756-PA72 85-265 VAC Power Supply (5V @ 10 Amp) 884.76 884.76 2 1756-TBCH 36 Pin Screw Clamp Block With Standard Housing 81.81 163.62 MVI561 PDPMV1 PROFIBUS Master V1 Communication Module N/A N/A Subtotal: 17926.51 CLX_SS.1.DIO_SS.1_FLX001 1 1794-ACN15 17941 IB16XOB16P Single Media Adapter For ControlNet 24V DC Combo Module, 16 Input, 16 Output 16 727.2 727.2 601.96 601.96 PumpStation5 Documentation Reference / Version 1 1794-TB32 32-channel screw terminal base (32 I/O; 8 common; 8 +V ) 196.95 Subtotal: 196.95 1526.11 653.47 Subtotal: 653.47 653.47 Consolidated Network Spool Cables 1 1786-RG6 RG-6 Quad Shield Coax Cable (1.0m total reqd.) Total: The pricing provided is List Price. Please consult your local sales person to get your specific pricing. 17 20359.69 PumpStation5 Documentation Reference / Version 18 PumpStation5 Documentation Reference / Version 3 Network Details 3.1 Network 'ControlNet001' ControlNet network status : Ok 3.1.1 Graphics: Bird's eye view Segment : Segment_1 19 PumpStation5 Documentation Reference / Version 3.1.2 Performance Data: Propagation delay 0% Network Update Time (NUT) 10 ms Max bytes available per NUT 5604 bytes 3.1.3 Layout Information: Segment_1 A#1, CLX_SS.1_CLogix001, [3], 1756-CN2 A#2, CLX_SS.1.DIO_SS.1_FLX001, [-], 1794-ACN15 20 Average bytes scheduled per NUT 27 bytes PumpStation5 Documentation Reference / Version 3.2 Network 'ProfiBus001' ProfiBus network status : 3.2.1 Graphics: 3.2.2 Performance Data: Unable to obtain Performance Data for this network. 3.2.3 Layout Information: A#0, CLX_SS.1_CLogix001, [2], MVI56-PDPMV1 21 PumpStation5 Documentation Reference / Version 22 PumpStation5 Documentation Reference / Version 4 Hardware Platforms 4.1 Platform 'CLX_SS.1_CLogix001' 4.1.1 Graphics: 4.1.2 Performance Data: Processor Connections and Memory Usage: Chassis / Optimized? Connections Device Name used CLX_SS.1_C Yes 7 Logix001 CLX_SS.1.DI Yes 1 O_SS.1_FLX 001 1782.8 Kbytes free. 265.3 Kbytes used out of 2048.0. (12.0 Kbytes are reserved for the applications.) Memory used Power Status 246528 Ok 12800 Ok Power Error Message 492 connections available. 8 connections used out of 500. (including 0 produced tags 0 reserved connections.) Power supply 1756-PA72 mA remaining on 5V 4740.000000 mA remaining on 24V 2719.000000 Max 5V Max 24V 10000.000000 2800.000000 4.1.3 Layout Information: Slot # Catalog # Additional Information 23 PumpStation5 Documentation Reference / Version N/A N/A 0 1 1756-A10 1756-PA72 1756-L71 1756-EN2T not connected 2 MVI56-PDPMV1 connected to network 'ProfiBus001' at address 0 3 1756-CN2 connected to network 'ControlNet001' at address 1 4 4.1 4.1.1 4.1.2 5 5.1 5.1.1 5.1.2 6 6.1 6.1.1 6.1.2 7 7.1 7.1.1 7.1.2 8 8.1 9 9.1 1756-IF16 HEADERNODE 1492-AIFM8-3 1492-ACABLE025UA 1756-IB32 HEADERNODE 1492-IFM40F 1492-CABLE025Z 1756-OV32E HEADERNODE 1492-IFM40F 1492-CABLE025Z 1756-OV32E HEADERNODE 1492-IFM40F 1492-CABLE025Z 1756-IB32 1756-TBCH 1756-OV32E 1756-TBCH 4.1.4 Cable Report for OnMach002 4.1.4.1 OnMach002: Wiring System Module: 1492-AIFM8-3 24 PumpStation5 Documentation Reference / Version 4.1.5 Cable Report for OnMach003 4.1.5.1 OnMach003: Wiring System Module: 1492-IFM40F 25 PumpStation5 Documentation Reference / Version 4.1.6 Cable Report for OnMach004 4.1.6.1 OnMach004: Wiring System Module: 1492-IFM40F 26 PumpStation5 Documentation Reference / Version 4.1.7 Cable Report for OnMach005 4.1.7.1 OnMach005: Wiring System Module: 1492-IFM40F 27 PumpStation5 Documentation Reference / Version 28 PumpStation5 Documentation Reference / Version 4.2 Platform 'CLX_SS.1.DIO_SS.1_FLX001' 4.2.1 Graphics: 4.2.2 Performance Data: Power supply 1794-PS13 mA remaining on 5V 610.000000 mA remaining on 24V 900.000000 Max 5V Max 24V 0.000000 1300.000000 4.2.3 Layout Information: Slot # 0 Catalog # 1794-ACN15 1 1.1 1794-IB16XOB16P 1794-TB32 Additional Information connected to network 'ControlNet001' at address 2 29 PumpStation5 Documentation Reference / Version 5 Appendix: 30 PumpStation5 Documentation Reference / Version 31