PumpStation5

advertisement
PumpStation5 Documentation
Reference / Version
Integrated Architecture Builder
PumpStation5
Project Documentation
Reference
Version
Monday, May 07, 2012 - 13:52
/
Author
1
PumpStation5 Documentation
Reference / Version
Table of Contents:
1 Overview of Project 'PumpStation5' ........................................................................ 4
1.1 IAB Software Information: ............................................................................... 4
1.2 Integrated Architecture.................................................................................... 5
1.3 ControlLogix ................................................................................................... 7
1.4 In-Cabinet Modular Distributed I/O ................................................................... 9
1.5 Project's System List...................................................................................... 12
1.6 Project Errors/Warnings ................................................................................. 12
1.7 Project's Network list ..................................................................................... 12
1.8 Project's hardware platforms list ..................................................................... 12
1.9 Architecture View .......................................................................................... 12
2 Bill of Materials ................................................................................................... 12
2.1 Consolidated BOM ......................................................................................... 13
2.2 Positional BOM .............................................................................................. 14
2.3 Organized BOM ............................................................................................. 16
3 Network Details .................................................................................................. 19
3.1 Network 'ControlNet001' ................................................................................ 19
3.1.1 Graphics: .............................................................................................................. 19
3.1.2 Performance Data: ................................................................................................. 20
3.1.3 Layout Information: ............................................................................................... 20
3.2 Network 'ProfiBus001'.................................................................................... 21
3.2.1 Graphics: .............................................................................................................. 21
3.2.2 Performance Data: ................................................................................................. 21
3.2.3 Layout Information: ............................................................................................... 21
4 Hardware Platforms ............................................................................................ 23
4.1 Platform 'CLX_SS.1_CLogix001' ...................................................................... 23
4.1.1 Graphics: .............................................................................................................. 23
4.1.2 Performance Data: ................................................................................................. 23
4.1.3 Layout Information: ............................................................................................... 23
4.1.4 Cable Report for OnMach002 .................................................................................. 24
4.1.4.1 OnMach002: ..................................................................................... 24
4.1.5 Cable Report for OnMach003 .................................................................................. 25
4.1.5.1 OnMach003: ..................................................................................... 25
4.1.6 Cable Report for OnMach004 .................................................................................. 26
4.1.6.1 OnMach004: ..................................................................................... 26
4.1.7 Cable Report for OnMach005 .................................................................................. 27
4.1.7.1 OnMach005: ..................................................................................... 27
2
PumpStation5 Documentation
Reference / Version
4.2 Platform 'CLX_SS.1.DIO_SS.1_FLX001'............................................................ 29
4.2.1 Graphics: .............................................................................................................. 29
4.2.2 Performance Data: ................................................................................................. 29
4.2.3 Layout Information: ............................................................................................... 29
5 Appendix: .......................................................................................................... 30
3
PumpStation5 Documentation
Reference / Version
1 Overview of Project 'PumpStation5'
1.1 IAB Software Information:
Integrated Architecture Builder software is a tool designed to assist you in defining an
automation configuration. While Integrated Architecture Builder Software has been
designed and tested for accuracy and Bill of Material completeness, the underlying
variables and assumptions of the tool may cause actual results to vary from expected
results. Users of Integrated Architecture Builder software must independently determine
to their own satisfaction the applicability of the resulting configuration and must assume
responsibility for the use of the resulting configuration and bill of material. Integrated
Architecture Builder software provides informational data on expected performance
results. Rockwell Automation is not liable for the correctness of this data.
Processor Checks:
The Processor Chassis Checkers check the processor and any associated I/O and
devices. The checker examines power consumption of all chassis, estimates memory
requirements for the processor(s), and counts connections for the Processor and any
local communication modules necessary to handle the network bandwidth. Any device
that is "owned" by this processor will be accounted for when performing the check.
ControlNet Network Checks:
The ControlNet Wizard checks the device connections, network cabling components,
and additional performance information about the network. Given certain information
about device connectivity to processors and basic network setup information, the
ControlNet wizard will check details on scheduled and unscheduled bandwidth,
propagation delay, and Network Update Time. Results are based on approximate
DeviceNet Network Checks:
The DeviceNet Wizard checks the device connections and network cabling (trunk, taps
and drops). It also verifies correct network sizing (power consumption, maximum length
and Baud rate).
EtherNet Network Checks:
The EtherNet Wizard checks the device connections, network cabling components, and
additional performance information about the network. Given certain information about
device connectivity to processors and basic network setup information, the EtherNet
wizard will check details on CIP / TCP connections, I/O packets per second, and HMI
packets per seconds.
4
PumpStation5 Documentation
Reference / Version
1.2 Integrated Architecture
The Convergence of Control and Information for Plantwide Optimization
The Rockwell Automation Integrated Architecture™ system helps you to build a business in which
information flows across your organization so you can better address key market challenges:

Productivity
Improve PRODUCTIVITY with better asset utilization and system performance.
o Develop a standard set of engineering objects you can use across all of your
applications
o Merge the production floor with the enterprise system to improve data flow and
make faster, more informed business decisions
o Improve uptime, increase speed and simplify integration using intelligent devices
o Take advantage of a single network infrastructure

Innovation
Cultivate INNOVATION with increased system flexibility and technical risk mitigation.
o Invest less time in development so that you can spend more time creating new
intellectual property
o Quickly make production changes to better meet market demands
o Mix industrial, business and commercial technologies to solve business
challenges in new ways
o Share best practices

Globalization
Promote GLOBALIZATION with easy access to actionable, plantwide information.
o Easily extract, share and use information across your enterprise and around the
world directly from manufacturing assets like your controllers
o Track your manufacturing assets on a global basis
o Take advantage of a single, global standard

Sustainability
Support SUSTAINABILITY with extended product lifecycles and better asset utilization.
o Reduce waste by specifying a system in a footprint that meets your needs
o Reduce energy costs by eliminating the need to "over-design"
o Streamline required assets and simultaneously reduce storage, energy costs,
and waste materials
5
PumpStation5 Documentation
Reference / Version
How does the Integrated Architecture system accomplish this? By leveraging exceptional,
industry-leading features that include:

Multiple Disciplines — Functionality for a full range of automation applications with
common equipment and standards

Scalable Dimensions — Offerings that are right-sized by product, architecture and
core multiple discipline functionality

EtherNet/IP — A single network of IT-friendly Ethernet for information, I/O and motion

Real-Time Information — Live data and open access throughout your power and
control system, enterprise and supply chain

Knowledge Integration — Premier integration of device and system to maximize and
secure your intellectual property
The Integrated Architecture system provides the foundation to drive plantwide optimization
efficiently and effectively, helping companies to respond competitively to the economy and
changes in consumer demand.
6
PumpStation5 Documentation
Reference / Version
1.3 ControlLogix
For manufacturers, OEMs and Systems Integrators in virtually every industry, the Logix Control
Platform increases productivity while reducing total cost of ownership.
Unlike conventional architectures, the Logix Control Platform provides fully integrated, scalable
solutions for the full range of automation disciplines including discrete, motion, process control,
batch, drive systems and safety using a single control platform, a single development
environment and using a single, open communication protocol. The platform enables you to reuse engineering designs and practices to reduce development time and cost, respond more
quickly to customer or market demands, reduce maintenance costs and downtime and easily gain
access to actionable plant and production information for improved management and decisionmaking.
ControlLogix Programmable Automation Controller
The Most Powerful, Most Expandable Controller
ControlLogix brings together the benefits of the Logix platform—common programming
environment, common networks, common control engine—to provide you with the performance
your application requires in an easy-to-use environment. As part of the Logix Control Platform,
you receive tight integration between the programming software, controller and I/O to reduce
development time and cost at commissioning and during normal operation.

Mix multiple controllers, networks
and I/O without restrictions to
address all disciplines

Mix standard and safety control in
same chassis
The ControlLogix programmable automation controller (PAC) features a modular control platform
with virtually infinite expansion of controllers, networks and I/O. With memory options up to
32MB, ControlLogix controllers support intensive process applications and provide fast
processing of motion instructions in a single integrated solution.
ControlLogix provides modular network communications that let you purchase only what you
need. Interface using ControlLogix communication modules via a ControlLogix gateway without
the need for a processor in the gateway chassis, or interface directly to a ControlLogix processor.
You may also combine any number of EtherNet/IP, ControlNet, DeviceNet, HART, FOUNDATION
fieldbus, or other networks for maximum communications flexibility. Or, you may route and bridge
between CIP (Common Industrial Protocol) networks with no controller overhead.
7
PumpStation5 Documentation
Reference / Version
ControlLogix controllers also support redundant architectures with no additional programming or
customized controllers for high availability. The primary controller automatically updates the
secondary with any data changes needed to keep it synchronized.
Additionally, standard ControlLogix products are certified by TUV for use in Safety Integrity Level
(SIL) 1 and SIL 2 applications. By using the same platform and
development software as standard control systems, you may
reduce development costs.
In terms of I/O, the ControlLogix platform provides a full range
of digital, diagnostic digital, analog, motion control, and
specialty I/O to meet a variety of application needs. Use any of
the I/O modules in the local chassis of a ControlLogix controller
or in a chassis linked to a ControlLogix controller across
ControlNet™ or EtherNet/IP™ networks.
Development Environment
Streamline engineering with outstanding ease-of-use
With RSLogix 5000, only one software package is needed for discrete, process, batch, motion,
safety and drive-based applications. RSLogix 5000 offers an easy-to-use, IEC61131-3 compliant
interface, symbolic programming with structures and arrays and a comprehensive instruction set
that serves many types of applications. It provides ladder logic, structured text, function block
diagram and sequential function chart editors for program development as well as support for the
S88 equipment phase state model for batch and machine control applications. RSLogix 5000 can
help:
•
reduce programming and ease startup and commissioning
•
ease diagnostics and troubleshooting
•
increase overall plant productivity
8
PumpStation5 Documentation
Reference / Version
1.4 In-Cabinet Modular Distributed I/O
In-Cabinet (IP20) distributed I/O can be placed throughout your application and requires an
enclosure. Our In-Cabinet Modular I/O products let you select the exact mix of I/O interfaces and
communication adapters to fit your needs, providing greater flexibility in designing your system. In
addition to a wide range of analog, digital, and specialty modules, we provide in-cabinet I/O
options for extreme environments, I/O for safety systems, and intrinsic safety (IS) I/O that can be
distributed throughout hazardous areas.
1734 POINT I/O
Bulletin 1734 POINT I/O™ is ideal for applications requiring flexibility and low cost of ownership.
Granularity of one to eight points lets you buy only the I/O you need. The compact design makes
installation easier in limited panel space. The family includes POINT Guard I/O™ safety-rated I/O
modules that can be used side-by-side in a standard POINT I/O system. Network connectivity
includes ControlNet™, DeviceNet™, EtherNet/IP™, and other open networks. Some modules
feature DeviceLogix™ Smart Component Technology, integrating low-cost logic solving capability
in your I/O for faster sense-to-actuation times.
Features








Modular design lets you
independently select the I/O,
termination style and network
interface
Components install easily by
sliding together; pull apart easily
for maintenance
Removable wiring system saves
time and money during
installation and troubleshooting
Comprehensive diagnostics and
configurable features makes
POINT I/O™ easy to apply
Removal and Insertion Under
Power (RIUP) lets you replace
modules while the system is in
operation
Mount horizontally or vertically,
with no de-rating required
Auto Device Replacement
(ADR) lets OEMs add features
and I/O with minimal effort
Add-On-Profiles in RSLogix
5000 programming software
provide smooth integration into
Integrated Architecture systems
1794 FLEX I/O
FLEX™ I/O offers the functionality of larger rack-based I/O without the space requirements. FLEX
I/O offers cost-effectiveness, flexibility, modularity, and reliability. Communication options include
9
PumpStation5 Documentation
Reference / Version
EtherNet/IP™, ControlNet™, DeviceNet™, Universal Remote I/O, and other networks. FLEX-I/O
XT™ modules provide a distributed I/O solution for your ControlLogix-XT™ extreme environment
system.
Features







Modular design lets you
independently select the I/O,
termination style and network
interface
Assembles without tools—all
components snap onto a DIN
rail and plug together to form
the I/O system
Mounts horizontally or vertically
on a standard DIN rail
Communicates on
EtherNet/IP™, ControlNet™,
DeviceNet™, Universal Remote
I/O, and other networks
Removal and Insertion Under
Power (RIUP) lets you replace
modules and make connections
while the system is in operation
FLEX-I/O XT™ extreme
environment modules operate in
a broader temperature range
and are ANSI/ISA2, IEC and
EMC-compliant
Configuration wizards speed
engineering and installation
1797 FLEX Ex I/O
Bulletin 1797 FLEX Ex™ Intrinsic Safety (IS) I/O couples the benefits of our FLEX™ I/O platform
with IS technology. This lets you distribute I/O throughout hazardous areas with a single or
redundant fiber or coax cable, virtually eliminating standalone IS barriers and isolators,
enclosures, long wiring runs, and cable trays. FLEX Ex I/O communicates with your control
system over a ControlNet™ network. It is compatible with standard FLEX I/O and communication
modules for added flexibility in network choices and system configuration.
10
PumpStation5 Documentation
Reference / Version
Features







11
Installs into hazardous areas
(Zone 1) without purged or
explosion-proof enclosures
Provides a ControlNet-based
solution in the hazardous area
using ControlNet™ Ex products
Modular design lets you
independently select the I/O,
termination style and network
interface
Assembles without tools—all
components snap onto a DIN
rail and plug together to form
the I/O system
Mounts horizontally or vertically
on a standard DIN rail
Removal and Insertion Under
Power (RIUP) lets you replace
modules and make connections
in the hazardous area while the
system is in operation
Simplified engineering
drawings, documentation, and
site certification speed
commissioning
PumpStation5 Documentation
Reference / Version
1.5 Project's System List
This Project contains the following Systems:
System: New System
Subsystem: CLX_SS.1
1.6 Project Errors/Warnings
With IAB implemented rules, project general status is OK.
1.7 Project's Network list
Network Type
ControlNet
ProfiBus
This Project contains the following networks:
Network Name
ControlNet001
ProfiBus001
Network Status
Ok
1.8 Project's hardware platforms list
This Project contains the following Hardware platforms:
HW Platform Type
HW Platform Name
ControlLogix
CLX_SS.1_CLogix001
Flex
CLX_SS.1.DIO_SS.1_FLX001
1.9 Architecture View
2 Bill of Materials
12
PumpStation5 Documentation
Reference / Version
2.1 Consolidated BOM
System Status :
Qty Catalog #
Description
1 1756-A10
1756 Chassis 10 slots
1 1756-PA72
85-265 VAC Power Supply (5V @ 10 Amp)
1 1756-L71
Logix5671 Processor With 2 Mbytes Memory
1 1756-EN2T
EtherNet 10-100M Bridge Module
MVI561 PDPMV1
PROFIBUS Master V1 Communication Module
1 1756-CN2
ControlNet Interface Module
1 1756-IF16
Analog Input - Current/Voltage 16 Pts (36 Pin)
1 1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input
1492Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20 Conductors, #22
1 ACABLE025UA AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin D-shell Connector
1 1794-ACN15 Single Media Adapter For ControlNet
17941 IB16XOB16P 24V DC Combo Module, 16 Input, 16 Output
1 1794-TB32
32-channel screw terminal base (32 I/O; 8 common; 8 +V )
1 1786-RG6
RG-6 Quad Shield Coax Cable (1.0m total reqd.)
2 1756-IB32
10-31 VDC Input 32 Pts (36 Pin)
2 1756-TBCH
36 Pin Screw Clamp Block With Standard Housing
2 1786-XT
ControlNet BNC Terminator
2 1786-TPS
ControlNet Straight T-Tap
3 1492-IFM40F 40-Point Feed-Through Digital IFM, Standard
1492Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH
3 CABLE025Z
connector & IFM 40-pin connector
3 1756-OV32E 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin)
Unit
Price Price
596.91 596.91
884.76 884.76
5250
5250
2787.6 2787.6
N/A
N/A
2110.9 2110.9
1504.9 1504.9
140.39 140.39
313.1
727.2
313.1
727.2
601.96
196.95
653.47
461.57
81.81
9.64
117.16
131.3
601.96
196.95
653.47
923.14
163.62
19.28
234.32
393.9
295.93
656.5
887.79
1969.5
Total: 20359.69
13
PumpStation5 Documentation
Reference / Version
2.2 Positional BOM
System Status :
Pos/Slot Catalog #
Description
Networks
Unit Price
Price
ControlNet001 : Segment_1
N/A
1786-RG6
0 1786-XT
RG-6 Quad Shield Coax Cable (1.00 m reqd.)
ControlNet BNC Terminator
0 1756-CN2
0 1786-TPS
(CLX_SS.1_CLogix001) ControlNet Interface Module
ControlNet Straight T-Tap
1 1794-ACN15
1 1786-TPS
1 1786-XT
(CLX_SS.1.DIO_SS.1_FLX001) Single Media Adapter For ControlNet
ControlNet Straight T-Tap
ControlNet BNC Terminator
Included in
Included in
Bulk Cable
Bulk Cable
Section
Section
9.64
9.64
Included in
Included in
Hardware
Hardware
Section
Section
117.16
117.16
Included in
Included in
Hardware
Hardware
Section
Section
117.16
117.16
9.64
9.64
Subtotal:
253.6
ProfiBus001
MVI561 PDPMV1
(CLX_SS.1_CLogix001) PROFIBUS Master V1 Communication Module
Included in
Hardware
Section
Subtotal:
Included in
Hardware
Section
0
Hardware
CLX_SS.1_CLogix001
N/A
N/A
1756-A10
1756-PA72
0 1756-L71
1 1756-EN2T
MVI562 PDPMV1
3 1756-CN2
4 1756-IF16
1756 Chassis 10 slots
85-265 VAC Power Supply (5V @ 10 Amp)
Logix5671 Processor With 2 Mbytes Memory
EtherNet 10-100M Bridge Module
PROFIBUS Master V1 Communication Module
ControlNet Interface Module
Analog Input - Current/Voltage 16 Pts (36 Pin)
On-Machine BOM (OnMach002)
1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input
Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20
1492Conductors, #22 AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin DACABLE025UA shell Connector
5 1756-IB32
10-31 VDC Input 32 Pts (36 Pin)
On-Machine BOM (OnMach003)
1492-IFM40F
1492CABLE025Z
6 1756-OV32E
1492-IFM40F
40-Point Feed-Through Digital IFM, Standard
Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG,
w/1756-TBCH connector & IFM 40-pin connector
10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin)
On-Machine BOM (OnMach004)
40-Point Feed-Through Digital IFM, Standard
14
596.91
884.76
5250
2787.6
N/A
596.91
884.76
5250
2787.6
N/A
2110.9
1504.9
2110.9
1504.9
140.39
140.39
313.1
461.57
313.1
461.57
131.3
131.3
295.93
656.5
295.93
656.5
131.3
131.3
PumpStation5 Documentation
Reference / Version
1492CABLE025Z
7 1756-OV32E
Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG,
w/1756-TBCH connector & IFM 40-pin connector
10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin)
On-Machine BOM (OnMach005)
1492-IFM40F
1492CABLE025Z
8 1756-IB32
1756-TBCH
9 1756-OV32E
1756-TBCH
40-Point Feed-Through Digital IFM, Standard
Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG,
w/1756-TBCH connector & IFM 40-pin connector
10-31 VDC Input 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
295.93
656.5
295.93
656.5
131.3
131.3
295.93
461.57
81.81
656.5
81.81
Subtotal:
295.93
461.57
81.81
656.5
81.81
17926.51
727.2
727.2
601.96
196.95
Subtotal:
601.96
196.95
1526.11
653.47
Subtotal:
653.47
653.47
CLX_SS.1.DIO_SS.1_FLX001
0 1794-ACN15
17941 IB16XOB16P
1794-TB32
Single Media Adapter For ControlNet
24V DC Combo Module, 16 Input, 16 Output
32-channel screw terminal base (32 I/O; 8 common; 8 +V )
Consolidated Network Spool Cables
N/A
1786-RG6
RG-6 Quad Shield Coax Cable (1.0m total reqd.)
Total:
The pricing provided is List Price. Please consult
your local sales person to get your specific pricing.
15
20359.69
PumpStation5 Documentation
Reference / Version
2.3 Organized BOM
System Status :
Qty Catalog #
Description
Networks
Unit Price
Price
ControlNet001 : Segment_1
1 1756-CN2
(CLX_SS.1_CLogix001) ControlNet Interface Module
1 1786-RG6
2 1786-TPS
2 1786-XT
RG-6 Quad Shield Coax Cable (1.00 m reqd.)
ControlNet Straight T-Tap
ControlNet BNC Terminator
1 1794-ACN15
(CLX_SS.1.DIO_SS.1_FLX001) Single Media Adapter For ControlNet
Included in
Included in
Hardware
Hardware
Section
Section
Included in
Included in
Bulk Cable
Bulk Cable
Section
Section
117.16
234.32
9.64
19.28
Included in
Included in
Hardware
Hardware
Section
Section
Subtotal:
253.6
ProfiBus001
MVI561 PDPMV1
(CLX_SS.1_CLogix001) PROFIBUS Master V1 Communication Module
Included in
Hardware
Section
Subtotal:
Included in
Hardware
Section
0
Hardware
CLX_SS.1_CLogix001
Pre-wired cable for 1756-IF16 (S-Ended Voltage) Analog Input Modules, 20
1492Conductors, #22 AWG, Shielded, w/1756-TBCH connector & AIFM 25-pin D1 ACABLE025UA shell Connector
313.1
313.1
1 1492-AIFM8-3 Feed-Through 8 Channel Analog IFM, 3 Terminals per Input
140.39
140.39
1492Pre-wired cable for 1756 32-pt I/O Modules, 40 conductors, #22 AWG, w/17563 CABLE025Z
TBCH connector & IFM 40-pin connector
295.93
887.79
3 1492-IFM40F 40-Point Feed-Through Digital IFM, Standard
131.3
393.9
1 1756-A10
1756 Chassis 10 slots
596.91
596.91
1 1756-CN2
ControlNet Interface Module
2110.9
2110.9
1 1756-EN2T
EtherNet 10-100M Bridge Module
2787.6
2787.6
2 1756-IB32
10-31 VDC Input 32 Pts (36 Pin)
461.57
923.14
1 1756-IF16
Analog Input - Current/Voltage 16 Pts (36 Pin)
1504.9
1504.9
1 1756-L71
Logix5671 Processor With 2 Mbytes Memory
5250
5250
3 1756-OV32E 10-30 VDC Electronically Fused Sinking Output 32 Points (36 Pin)
656.5
1969.5
1 1756-PA72
85-265 VAC Power Supply (5V @ 10 Amp)
884.76
884.76
2 1756-TBCH
36 Pin Screw Clamp Block With Standard Housing
81.81
163.62
MVI561 PDPMV1
PROFIBUS Master V1 Communication Module
N/A
N/A
Subtotal:
17926.51
CLX_SS.1.DIO_SS.1_FLX001
1 1794-ACN15
17941 IB16XOB16P
Single Media Adapter For ControlNet
24V DC Combo Module, 16 Input, 16 Output
16
727.2
727.2
601.96
601.96
PumpStation5 Documentation
Reference / Version
1 1794-TB32
32-channel screw terminal base (32 I/O; 8 common; 8 +V )
196.95
Subtotal:
196.95
1526.11
653.47
Subtotal:
653.47
653.47
Consolidated Network Spool Cables
1 1786-RG6
RG-6 Quad Shield Coax Cable (1.0m total reqd.)
Total:
The pricing provided is List Price. Please consult
your local sales person to get your specific pricing.
17
20359.69
PumpStation5 Documentation
Reference / Version
18
PumpStation5 Documentation
Reference / Version
3 Network Details
3.1 Network 'ControlNet001'
ControlNet network status : Ok
3.1.1 Graphics:
Bird's eye view
Segment : Segment_1
19
PumpStation5 Documentation
Reference / Version
3.1.2 Performance Data:
Propagation delay
0%
Network Update Time
(NUT)
10 ms
Max bytes available
per NUT
5604 bytes
3.1.3 Layout Information:
Segment_1
A#1, CLX_SS.1_CLogix001, [3], 1756-CN2
A#2, CLX_SS.1.DIO_SS.1_FLX001, [-], 1794-ACN15
20
Average bytes
scheduled per NUT
27 bytes
PumpStation5 Documentation
Reference / Version
3.2 Network 'ProfiBus001'
ProfiBus network status :
3.2.1 Graphics:
3.2.2 Performance Data:
Unable to obtain Performance Data for this network.
3.2.3 Layout Information:
A#0, CLX_SS.1_CLogix001, [2], MVI56-PDPMV1
21
PumpStation5 Documentation
Reference / Version
22
PumpStation5 Documentation
Reference / Version
4 Hardware Platforms
4.1 Platform 'CLX_SS.1_CLogix001'
4.1.1 Graphics:
4.1.2 Performance Data:
Processor Connections and Memory Usage:
Chassis /
Optimized?
Connections
Device Name
used
CLX_SS.1_C Yes
7
Logix001
CLX_SS.1.DI Yes
1
O_SS.1_FLX
001
1782.8 Kbytes free.
265.3 Kbytes used out of 2048.0.
(12.0 Kbytes are reserved for the applications.)
Memory used
Power Status
246528
Ok
12800
Ok
Power Error
Message
492 connections available.
8 connections used out of 500.
(including 0 produced tags 0 reserved connections.)
Power supply
1756-PA72
mA remaining on
5V
4740.000000
mA remaining on
24V
2719.000000
Max 5V
Max 24V
10000.000000
2800.000000
4.1.3 Layout Information:
Slot #
Catalog #
Additional Information
23
PumpStation5 Documentation
Reference / Version
N/A
N/A
0
1
1756-A10
1756-PA72
1756-L71
1756-EN2T
not connected
2
MVI56-PDPMV1
connected to network 'ProfiBus001' at address 0
3
1756-CN2
connected to network 'ControlNet001' at address 1
4
4.1
4.1.1
4.1.2
5
5.1
5.1.1
5.1.2
6
6.1
6.1.1
6.1.2
7
7.1
7.1.1
7.1.2
8
8.1
9
9.1
1756-IF16
HEADERNODE
1492-AIFM8-3
1492-ACABLE025UA
1756-IB32
HEADERNODE
1492-IFM40F
1492-CABLE025Z
1756-OV32E
HEADERNODE
1492-IFM40F
1492-CABLE025Z
1756-OV32E
HEADERNODE
1492-IFM40F
1492-CABLE025Z
1756-IB32
1756-TBCH
1756-OV32E
1756-TBCH
4.1.4 Cable Report for OnMach002
4.1.4.1 OnMach002:
Wiring System Module: 1492-AIFM8-3
24
PumpStation5 Documentation
Reference / Version
4.1.5 Cable Report for OnMach003
4.1.5.1 OnMach003:
Wiring System Module: 1492-IFM40F
25
PumpStation5 Documentation
Reference / Version
4.1.6 Cable Report for OnMach004
4.1.6.1 OnMach004:
Wiring System Module: 1492-IFM40F
26
PumpStation5 Documentation
Reference / Version
4.1.7 Cable Report for OnMach005
4.1.7.1 OnMach005:
Wiring System Module: 1492-IFM40F
27
PumpStation5 Documentation
Reference / Version
28
PumpStation5 Documentation
Reference / Version
4.2 Platform 'CLX_SS.1.DIO_SS.1_FLX001'
4.2.1 Graphics:
4.2.2 Performance Data:
Power supply
1794-PS13
mA remaining on
5V
610.000000
mA remaining on
24V
900.000000
Max 5V
Max 24V
0.000000
1300.000000
4.2.3 Layout Information:
Slot #
0
Catalog #
1794-ACN15
1
1.1
1794-IB16XOB16P
1794-TB32
Additional Information
connected to network 'ControlNet001' at address 2
29
PumpStation5 Documentation
Reference / Version
5 Appendix:
30
PumpStation5 Documentation
Reference / Version
31
Download